Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "AC method" wg kryterium: Temat


Wyświetlanie 1-11 z 11
Tytuł:
Steady-state modelling method for matrix-reactance frequency converter with boost topology
Autorzy:
Korotyeyev, I.Ye.
Zięba, B.
Powiązania:
https://bibliotekanauki.pl/articles/140872.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
przekształtnik AC/AC
matrycowo-reaktancyjny przemiennik częstotliwości
metoda Galerkina
równanie różniczkowe
AC/AC converters
matrix-reactance frequency converter
Galerkin's method
extension of differential equations
Opis:
This paper presents a method intended for calculation of steady-state processes in AC/AC three-phase converters that are described by nonstationary periodical differential equations. The method is based on the extension of nonstationary differential equations and the use of Galerkin's method. The results of calculations are presented in the form of a double Fourier series. As an example, a three-phase matrix-reactance frequency converter (MRFC) with boost topology is considered and the results of computation are compared with a numerical method.
Źródło:
Archives of Electrical Engineering; 2011, 60, 2; 137-148
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie podwójnego szeregu Fouriera do analizy matrycowo-reaktancyjnego przekształtnika częstotliwości prądu przemiennego
Application of the double Fourier series to analysis of AC matrix-reactance frequency converters
Autorzy:
Zięba, B.
Korotyeyev, I.
Powiązania:
https://bibliotekanauki.pl/articles/155909.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
matrycowo- reaktancyjny przekształtnik prądu przemiennego
modelowanie matematyczne
podwójny szereg Fouriera
metoda Galerkin
AC/AC matrix-reactance frequency converter
mathematical modelling
double Fourier series
Galerkin's method
Opis:
W artykule rozpatrzona została metoda przeznaczona do wyznaczania stanu ustalonego w matrycowo- reaktancyjnych przekształtnikach częstotliwości prądu przemiennego (MRFC z ang. matrix- reactance frequency converters). Metoda polega na rozszerzeniu niestacjonarnych równań różniczkowych opisujących przekształtnik o dodatkowe zmienne czasu, odpowiadające różnym częstotliwościom pracy obwodu. Aproksymacja rozwiązania jest otrzymana przy zastosowania metody Galerkina oraz wykorzystaniu podwójnych szeregów Fouriera, za pomocą których otrzymywane są prądy i napięcia w obwodzie. Rezultaty obliczeń zaprezentowane zostały na przykładzie MRFC i porównane z metodą numeryczną.
The purpose of this paper is to present a method for calculation of steady-state processes in AC/AC three-phase, matrix-reactance, frequency converters (MRFC) that are described by nonstationary periodical differential equations (1). The proposed method is based on extension of nonstationary differential equations and use of the Galerkin's method [1]. The differential equations are extended by additional, independent variables of time, corresponding to different pulsations in the circuit [2]. There is assumed that the ratio of the supply source and control signal periods is incommensurable. The solution is found by the Galerkin's metod with basis functions described by a double Fourier series [3]. The calculation results were verified by a numerical method. The calculations were obtained for steady-state processes in the three-phase MRFC with an RL load (Fig. 1). The calculation results are presented in the form of a double Fourier series. To verify the results obtained there was calculated the steady state in which both time variables were the same. The results were compared with the those obtained by the numerical method embedded in the program Mathematica (Figs. 5 and 6). A new method for solving nonstationary differential equations is presented. The method can be applied directly to finding the steady- state solution without any additional transformation of equations. Moreover, the steady state solution is obtained immediately, with-out any transient state.
Źródło:
Pomiary Automatyka Kontrola; 2012, R. 58, nr 1, 1; 33-36
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
FFT-PCA-LDA Classifier in A.C. Generator Diagnostics
Klasyfikator FFT-PCA-LDA w diagnostyce alternatora
Autorzy:
Skowronek, K.
Woźniak, A.
Powiązania:
https://bibliotekanauki.pl/articles/1366145.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
diagnostyka alternatora
klasyfikacja
metoda hybrydowa
A.C. generator diagnostics
classification
hybrid method
Opis:
The methods of A.C. generator diagnostics are discussed. The need of developing new methods is justified. A new classification method is presented that is used for diagnostics of A.C. generator damages. Features of the method are specified. Functioning of the method is analyzed based on examination of damages of A.C. generator diodes. The method is compared with other methods of electric machine diagnostics used in practice.
Omówiono metody diagnostyki alternatorów. Uzasadniono konieczność konstrukcji nowych metod. Zaprezentowano nową metodę klasyfikacyjną wykorzystaną do diagnostyki uszkodzeń alternatora. Przedstawiono cechy metody. Działanie metody przeanalizowano na podstawie badania uszkodzeń diod alternatora. Metodę porównano z metodami diagnostyki maszyn elektrycznych stosowanymi w praktyce.
Źródło:
Eksploatacja i Niezawodność; 2013, 15, 2; 140-146
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Instantaneous angular speed: encoder-counter estimation compared with vibration data
Autorzy:
Spagnol, M.
Bregant, L.
Powiązania:
https://bibliotekanauki.pl/articles/328776.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
instantaneous angular speed
encoder
elapsed time method
AC DC electrical machine
slip effect
Opis:
In rotating machinery, actions of the moving parts take place at specific angular positions rather than at specific times. For this reason, having a geometrical reference, such as the one provided by an encoder, and studying the Instantaneous Angular Speed (IAS) variations can provide a large amount of information about the health status of the machine. In fact, from the variation of the IAS during the machine loads’ cycle it is possible to identify defects and faults. The current work focuses on the estimation of the IAS through the Elapsed Time (ET) method, using a counter in order to measure the time elapsed between the pulses of an encoder. Both IAS and vibration measurement are conducted on an asynchronous four poles electrical motor driven by 50Hz line current, without load. The study compares the order analysis of both signals. The bearing’s Fundamental Train Frequency is detected using IAS estimation.
Źródło:
Diagnostyka; 2013, 14, 3; 9-13
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Niekonwencjonalna metoda wyznaczania nieliniowości całkowitej precyzyjnych mostków termometrycznych
Unconventional method of determination the nonlinearity of precision thermometric bridges
Autorzy:
Mikhal, A. A.
Warsza, Z. L.
Powiązania:
https://bibliotekanauki.pl/articles/972165.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
mostek AC
nieliniowość
dychotomia
rezystancja podwójna
AC bridge
nonlinearity
dichotomy method
double resistance
Opis:
Opracowano model metrologiczny mostków termometrycznych AC o najwyższej precyzji uwzględniający addytywną i multiplikatywną składową błędu oraz nieliniowość. Określono warunki, przy których pozostaje jedynie błąd liniowości mostka. Podano niekonwencjonalny sposób wyznaczania tego błędu, nazwany metodą dychotomii o algorytmie polegającym na dzieleniu zakresu pomiarowego i kolejno powstających jego części na połowę. Za pomocą graficznej interpretacji metody otrzymano analityczne wyrażenia dla błędu liniowości. Metoda wymaga zestawu par cztero-zaciskowych rezystorów wzorcowych. Mierzy się rezystancję każdego rezystora wzorcowego oraz szeregowego połączenia dwu jednakowych z nich. Rozpatrzono przyczyny niedokładności takiego sumowania fizycznego. Podano przykład wyznaczania błędu liniowości rzędu 0,1 ppm i poniżej.
The metrological model of high precision thermometric AC bridges is presented. It contains an additive, multiplicative and linearity errors. The conditions under which remains the linearity error only are given. Proposed is the unconventional method of measure and calculating the linearity error under name the dichotomy method, which has the algorithm based on the division of the measurement range and the subsequent intervals in half. In this method the additive linear function is applied. With the graphical interpretation the analytical expression for the error of linearity was obtained. This method can be easily implemented in any metrology lab. As the hardware proposed is the set of paired four terminal reference standard resistors. Measurements by tested bridge the resistance of each of them separately and of given the physical connection of them both has to be done. The reasons affecting the accuracy of the physical summation is discussed. On calculations and data of experimental examples is find that the measurement of the bridge linearity error of 0,1 ppm or less is possible.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 1, 1; 19-22
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Proste metody sprawdzania dokładności precyzyjnych mostków termometrycznych (2) Pomiary nieliniowości całkowitej metodą dychotomii
Simply calibration methods of the precise AC thermometric bridges (2) Measurement of integral nonlinearity by the dichotomy method
Autorzy:
Mikhal, A. A.
Warsza, Z. L.
Powiązania:
https://bibliotekanauki.pl/articles/276294.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
precyzyjny temperaturowy mostek AC
błąd liniowości
metoda dychotomii
wzorzec podwójnej rezystancji
precision AC thermometric bridge
integral and differential linearity errors
dichotomy method
double resistance standard
Opis:
W części pierwszej artykułu omówiono działanie i podstawowe parametry mostków AC z dzielnikiem indukcyjnym stosowanych do pomiarów temperatur wzorcowych. Zaproponowano prostą metodę kontroli ich wskazań dla rezystancji mierzonej równej zeru. W części drugiej omówiono zasady pomiaru temperatury wzorcowej precyzyjnymi mostkami prądu przemiennego (AC) oraz podano sposób kontroli liniowości mostków nazwany metodą dychotomii. Algorytm tej metody zakłada wykonanie pomiarów dla połowy zakresu i dla kolejnych jego części otrzymywanych po dzieleniu na połowę. Do realizacji służy zestaw kilku podwójnych rezystorów wzorcowych. Mostkiem podlegającym sprawdzaniu mierzy się każdą z dwu jednakowych 4-zaciskowych rezystancji wzorcowych oraz ich fizyczne szeregowe połączenie. Podano wyrażenia analityczne dla błędu liniowości mostka z uwzględnieniem oszacowania niedokładności takiego fizycznego sumowania rezystancji. Z przeprowadzonej analizy wynika, że metodą dychotomii (kolejnych podziałów zakresu na połowę), można wyznaczać błąd liniowości mostka nawet poniżej 0,1 ppm. Zbadano obiema zaproponowanymi metodami 7-cyfrowy mostek AC własnej konstrukcji. Błąd zera był poniżej 0,5 LSB, a błąd liniowości zawierał się w zakresie (0,5-2,1)•10-7. Metoda dychotomii jest dość prosta i można ją stosować w każdym laboratorium metrologicznym oraz wykorzystać do automatyzacji procesu kalibracji.
In part 1 backgrounds of operation and basic parameters of the high precision thermometric AC bridges with inductive dividers are described. The simply method of control their indication for measured resistance equal to zero is given and used for control zero of the home made bridge. In the following part 2, after short introduction the conditions of standard temperature measurements under which remains, only the linearity bridge errors are formulated. An unconventional method of measure and of estimating the bridge linearity error named as dichotomy method is proposed. Its algorithm is based on the division of the measurement range and then obtained subsequent intervals in half. Graphical interpretation and the analytical expression of the bridge linearity error are given. As reference for experimental use the set of standard resistors of paired four-terminal resistances are proposed. Each of two resistances and the given serial physical connection of them both have to be measured by tested bridge. The reasons affecting the accuracy of the physical realization of resistance summation is discussed. Through analysis and experimental verification is find that in measurements of the bridge linearity by dichotomy method (division into halves) the error of 0.1 ppm or less can be discovered. The 7-digit own design AC bridge was tested by both proposed methods. The zero error was less than 0.5 LSB, and the linearity error was in the range (0.5-2.1)•10-7. Presented dichotomy method is quite simple and. It can be easily implemented in any metrology lab and be applied in the automatic calibration.
Źródło:
Pomiary Automatyka Robotyka; 2013, 17, 10; 130-137
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Methods of small capacitance measurement in electrical capacitance tomography
Metody pomiaru małych pojemności w elektrycznej tomografii pojemnościowej
Autorzy:
Smolik, W.
Kryszyn, J.
Olszewski, T.
Szabatin, R.
Powiązania:
https://bibliotekanauki.pl/articles/408239.pdf
Data publikacji:
2017
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
capacitance measurement
AC method
charge-discharge method
electrical tomography
pomiar pojemności elektrycznej
metoda częstotliwościowa
metoda „ładuj-rozładuj”
tomografia elektryczna
Opis:
The paper presents the main methods of small capacitance measurement used in electrical capacitance tomography: the AC method with a sine wave excitation and the charge-discharge method with square wave excitation. Construction of synchronous detector for both circuits was discussed. A modified "charge-discharge" method was presented.
W artykule przedstawiono główne metody pomiaru małych pojemności stosowane w elektrycznej tomografii pojemnościowej: metodę częstotliwościową z pobudzeniem za pomocą fali sinusoidalnej oraz metodę „ładuj-rozładuj” z pobudzeniem za pomocą fali prostokątnej. Przedstawiono budowę detektora synchronicznego dla obu układów. Zaprezentowano również modyfikację metody „ładuj-rozładuj”
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2017, 7, 1; 105-110
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Predictive and look-up table control methods of a three-level AC-DC converter under distorted grid voltage
Autorzy:
Falkowski, P.
Kulikowski, K.
Grodzki, R.
Powiązania:
https://bibliotekanauki.pl/articles/201956.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
three-level AC/DC converter
direct power control
finite contol set model predictive control
lookup table method
AC/DC
trzypoziomowy konwerter AC/DC
Opis:
Power electronic three-level AC-DC converters connecting a utility grid with DC supplies are widely used in renewable energy sources. For such distributed systems, the quality of energy is very important. Hence, control algorithms of an AC-DC converter have to provide not only a sinusoidal shape of grid current, but also stable operation during transient states in the grid, e.g. voltage dips or voltage unbalance. This paper deals with the problem of robustness of AC-DC control methods under disturbed grid voltage. Three modern predictive control algorithms are presented and investigated under grid voltage distortions. Experimental results from a laboratory test setup illustrating properties of the described methods are shown.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2017, 65, 5; 609-618
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hybrydowa metoda pomiaru i jej zastosowanie w wysokoprecyzyjnym temperaturowym mostku AC
Hybrid Method of Measurement and its Use in High-Precision Thermometric AC Bridge
Autorzy:
Mikhal, A. A.
Meleshchuk, D. V.
Warsza, Z. L.
Powiązania:
https://bibliotekanauki.pl/articles/276848.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
dokładny pomiar temperatury
mostek AC
metoda hybrydowa
metoda kompensacyjno-ilorazowa
high accuracy temperature measurement
AC bridge
balanced-ratiometric method
hybrid method
Opis:
W artykule opisano oryginalną zasadę budowy układu pomiarowego automatycznego mostka AC (prądu przemiennego) służącego do bardzo dokładnych pomiarów temperatury za pomocą wzorcowego platynowego czujnika SPRT. Wykorzystuje się oryginalną metodę pomiaru, którą nazwano tu hybrydową. Obejmuje ona połączenie metody kompensacyjnej do zgrubnego zrównoważenia układu i metody ilorazowej (ratiometric), którą wyznacza się stosunek dwu wartości sygnału nierównowagi, przed i po znanej jego zmianie. Dzięki tej metodzie układ pomiarowy nie wymaga stosowania obwodu do kompensacji wpływu reaktancji czujnika SPRT. Zmniejsza się też niezbędna liczba dekad dzielnika indukcyjnego kompensującego zgrubnie sygnał składowej rezystancyjnej czujnika. Układ taki pozwala w prostszy sposób i przy niższych kosztach wykonania uzyskać tę samą dokładność, co najbardziej precyzyjne termometryczne mostki AC o układach w pełni zrównoważonych.
This article describes the principle of the circuit of an automatic AC bridge for high precision temperature measurements using a standard platinum SPRT sensor. The system uses an original measurement method, proposed was to call a hybrid method. It is a combination of a balanced method for rough compensation of the circuit and a ratiometric method which accurately measures the ratio of two values of the imbalance signal, before and after its known change. With this method, the measuring circuit does not require a part to compensate for the reactive component of the SPRT sensor impedance. The inductive voltage divider with lower number of digits is needed only for coarse compensation. This hybrid system is simpler and at lower cost allows to achieve the same accuracy as the most accurate thermometric bridges with fully balanced circuits.
Źródło:
Pomiary Automatyka Robotyka; 2018, 22, 1; 43-48
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of the hybrid balanced ratiometric measurement method in the high-precision ac thermometry bridges
Zastosowanie hybrydowej kompensacyjno-ilorazowej metody pomiaru w wysoko precyzyjnych temperaturowych mostkach AC
Autorzy:
Mikhal, A. A.
Meleshchuck, D.V.
Warsza, Z.L.
Powiązania:
https://bibliotekanauki.pl/articles/129543.pdf
Data publikacji:
2019
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
high precision temperature measurement
AC bridge
balanced-ratiometric measurement method
hybrid method
dokładny pomiar temperatury
mostek AC
metoda hybrydowa
metoda kompensacyjno-ilorazowa
Opis:
The paper article describes the circuit of an automatic AC bridge for high precision temperature measurements using a standard platinum SPRT sensor. An original method for measuring the impedance parameters of SPRT sensor which allows to carry out the measurement process without loss of accuracy, is described in detail. This measurement method is proposed to name as hybrid method. It is a combination of a balanced method for rough compensation of the circuit and a ratiometric method which accurately measures the ratio of two values of the imbalance signal, before and after its known change. With this method, the measuring circuit also does not require a circuit to compensate for the reactive component of the SPRT sensor impedance. The inductive voltage divider with lower number of digits is needed only for the coarse compensation. This circuit is simpler and at lower cost of the hardware resources allows to achieve the same accuracy as the most accurate thermometric bridges with fully balanced circuits.
W artykule opisano oryginalną zasadę budowy układu pomiarowego automatycznego mostka AC (prądu przemiennego) do bardzo dokładnych pomiarów temperatury za pomocą wzorcowego platynowego czujnika SPRT. Wykorzystuje się oryginalną kombinowaną, tj. kompensacyjno-ilorazową metodę pomiaru, którą nazwano tu krócej: metodą hybrydową. Obejmuje ona połączenie metody kompensacyjnej do zgrubnego zrównoważenia układu i metody ilorazowej (ratiometric), którą wyznacza się stosunek dwu wartości sygnału nierównowagi, przed i po znanej jego zmianie. Układ pomiarowy nie wymaga stosowania obwodu do kompensacji wpływu reaktancji czujnika SPRT. Zmniejsza się też niezbędna liczba dekad dzielnika indukcyjnego kompensującego zgrubnie sygnał składowej rezystancyjnej czujnika. Układ taki pozwala w prostszy sposób i przy niższychkosztach wykonania uzyskać tę samą dokładność co najdokładniejsze termometryczne mostki AC o układach całkowicie zrównoważonych.
Źródło:
Physics for Economy; 2019, 3, 1; 29-40
2544-7742
2544-7750
Pojawia się w:
Physics for Economy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Novel passive methods of periodical insulation resistance determination in AC/DC IT systems
Nowe metody pasywne okresowego wyznaczania rezystancji izolacji w układach AC/DC IT
Autorzy:
Olszowiec, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/27309778.pdf
Data publikacji:
2023
Wydawca:
Uniwersytet Technologiczno-Humanistyczny im. Kazimierza Pułaskiego w Radomiu
Tematy:
AC/DC IT systems
insulation
passive method
periodical measurement
układy AC/DC IT
izolacja
metoda pasywna
pomiar okresowy
Opis:
In the publication there is presented current status of development of passive methods of periodical insulation resistance determination in AC/DC IT systems. Their importance is strengthened by the fact that these procedures can be executed both manually by operator and by microprocessor monitors. Two novel methods offer a new approach which might be used also in other measuring applications. For better understanding of the proposed solutions there is given mathematical description of presence of DC components in voltages at both sides of rectifier. For the existing method of “Three Readings of a Voltmeter” and for new alternative techniques there is given an evaluation of their accuracy of insulation resistance determination.
W artykule przedstawiono aktualny stan rozwoju pasywnych metod okresowego wyznaczania rezystancji izolacji doziemnej w układach AC/DC IT. Podano dwa nowe sposoby realizacji tego zadania. Dla pełnego zrozumienia nowych rozwiązań pokazano matematyczne uzasadnienie zależności określających składowe DC w napięciach doziemnych obu stron prostownika diodowego. Dla istniejącej metody oraz jednej z proponowanych procedur oszacowano maksymalne możliwe błędy analitycznego wyznaczania wartości zastępczej rezystancji izolacji całego układu AC/DC IT.
Źródło:
Journal of Automation, Electronics and Electrical Engineering; 2023, 5, 1; 35--44
2658-2058
2719-2954
Pojawia się w:
Journal of Automation, Electronics and Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-11 z 11

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies