Considerations for starting combustion engines with AC machines
Autorzy:
Monroy, Mauricio
Romero, Carlos A.
Henao, Edison
Powiązania:
https://bibliotekanauki.pl/articles/2174476.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
internal combustion engine
starter motor
AC machine
torque requirements
ISG
supercapacitor
silnik spalinowy
rozrusznik
maszyna prądu przemiennego
superkondensator
Opis:
To initiate its combustion cycles, internal combustion engines require a minimum rotational speed that can be given from several sources (muscular, electrical, pneumatic, among others). Advantages of initiating an ICE with an AC electrical machine is that it can integrate starter motor and generator in one device, provide a linear ramp of acceleration when starting, and assist the ICE in torque production. This article illustrates considerations for the design of a starting system with an AC electrical machine. Initially, criteria of torque, rotational speed and power requirements are analysed, considering resistances of compression, friction, and inertia of the slider-crank mechanism, as well as accessories, with a preliminary experimental validation. Also, types of three-phase AC electrical machines are put to comparison, as well as their associated electronic components needed for driving them in each case, concluding that AC induction machines require a complex 4-quadrant inverter. PM synchronous machines require a simpler inverter, but with highly specified power electronics components. The classical wound rotor machine requires the simplest inverter, with unidirectional power flow, less power transfer losses and less critical power electronics components. Finally, considerations for using of a battery assisted with supercapacitor as complementary DC power source are made.
Źródło:
Diagnostyka; 2023, 24, 1; art. no. 2023102
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Instantaneous angular speed: encoder-counter estimation compared with vibration data
Autorzy:
Spagnol, M.
Bregant, L.
Powiązania:
https://bibliotekanauki.pl/articles/328776.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
instantaneous angular speed
encoder
elapsed time method
AC DC electrical machine
slip effect
Opis:
In rotating machinery, actions of the moving parts take place at specific angular positions rather than at specific times. For this reason, having a geometrical reference, such as the one provided by an encoder, and studying the Instantaneous Angular Speed (IAS) variations can provide a large amount of information about the health status of the machine. In fact, from the variation of the IAS during the machine loads’ cycle it is possible to identify defects and faults. The current work focuses on the estimation of the IAS through the Elapsed Time (ET) method, using a counter in order to measure the time elapsed between the pulses of an encoder. Both IAS and vibration measurement are conducted on an asynchronous four poles electrical motor driven by 50Hz line current, without load. The study compares the order analysis of both signals. The bearing’s Fundamental Train Frequency is detected using IAS estimation.
Źródło:
Diagnostyka; 2013, 14, 3; 9-13
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficiency improvement due to direct torque and flux three levels three areas control method applied to small hydroelectric power plant
Autorzy:
Kulikowski, K.
Sikorski, A.
Powiązania:
https://bibliotekanauki.pl/articles/200033.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
asynchronous machine
AC/DC/AC converter
DC/AC converter
DTC
flux control
Opis:
The paper presents a description of a new DTFC3L3A (direct torque and flux control three levels three areas) control method of induction machine as well as its comparison with the DTC method. The basis for the comparison is the switching frequency of described methods. The proposed method is optimized to reduce number of switchings (which is proportional to switching power losses) in static state, as well as it takes into account the angle which makes it possible to obtain a sinusoidal shape of flux within range of low angular frequencies of an asynchronous machine. The paper includes the results of experiments performed on a three level DC/AC inverter for both control methods.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2011, 59, 4; 569-574
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modern Direct Torque and Flux Control methods of an induction machine supplied by three-level inverter
Autorzy:
Sikorski, A.
Kulikowski, K.
Korzeniewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/201199.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
asynchronous machine
DC/AC inverter
DTC
flux and torque control
3-level DC/AC inverter
Opis:
This paper describes two modern direct torque and flux control methods of an induction machine supplied by a three-level inverter. Additionally, it presents a comparison of the methods both in static and dynamic states. The methods, in a specific way, make use of an increased number of active vectors of the three-level inverter in order to improve control quality and reduce switching frequency. The two methods modify the DTC method by using its advantages and eliminating, at the same time its drawbacks. In static states the comparison was based on the results of investigations performed for two different load values and three set values of angular speed, whereas in dynamic states the comparison was focused on the behavior of the machine at startup. The results of the investigations have shown that both methods give very good performance. They are characterized by both sinusoidal shape of flux and low current deformations even at low angular speeds i.e. less than 10% of the nominal value. The presented methods also allow to generate nominal flux for set zero angular speed in order to achieve excitation of the induction machine. The switching frequencies for both methods are very similar in almost the whole range of control but the methods have shown some differences in control quality, particularly for higher torque values.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2013, 61, 4; 771-778
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies