Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "źródło ciepła" wg kryterium: Temat


Tytuł:
A general study of fundamental solutions in aniotropicthermoelastic media with mass diffusion and voids
Autorzy:
Chawla, Vijay
Kamboj, Deepmala
Powiązania:
https://bibliotekanauki.pl/articles/1839675.pdf
Data publikacji:
2020
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
termosprężystość
dyfuzja masy
źródło ciepła
general solution
fundamental solution
thermoelastic
voids
mass diffusion
Opis:
The present paper deals with the study of a fundamental solution in transversely isotropic thermoelastic media with mass diffusion and voids. For this purpose, a two-dimensional general solution in transversely isotropic thermoelastic media with mass diffusion and voids is derived first. On the basis of the obtained general solution, the fundamental solution for a steady point heat source on the surface of a semi-infinite transversely isotropic thermoelastic material with mass diffusion and voids is derived by nine newly introduced harmonic functions. The components of displacement, stress, temperature distribution, mass concentration and voids are expressed in terms of elementary functions and are convenient to use. From the present investigation, some special cases of interest are also deduced and compared with the previous results obtained, which prove the correctness of the present result.
Źródło:
International Journal of Applied Mechanics and Engineering; 2020, 25, 4; 22-41
1734-4492
2353-9003
Pojawia się w:
International Journal of Applied Mechanics and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A numerical method for viscous flow in a driven cavity with heat and concentration sources placed on its side wall
Autorzy:
Ambethkar, V.
Basumatary, L. R.
Powiązania:
https://bibliotekanauki.pl/articles/122794.pdf
Data publikacji:
2018
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
numerical method
viscous flow
heat source
concentration source
driven square cavity
general algorithm
stability conditions
isotherms
streamlines
geometric center
heat and mass transfer
metoda numeryczna
lepki przepływ
źródło ciepła
warunki stabilności
izotermy
transfer ciepła
transfer masy
Opis:
This paper proposes a method to numerically study viscous incompressible two-dimensional steady flow in a driven square cavity with heat and concentration sources placed on its side wall. The method proposed here is based on streamfunction-vorticity (Ψ-ξ) formulation. We have modified this formulation in such a way that it suits to solve the continuity, x and y-momentum, energy and mass transfer equations which are the governing equations of the problem under investigation in this study. No-slip and slip wall boundary conditions for velocity, temperature and concentration are defined on walls of a driven square cavity. In order to numerically compute the streamfunction Ψ, vorticityfunction ξ , temperature θ, concentration C and pressure P at different low, moderate and high Reynolds numbers, a general algorithm was proposed. The sequence of steps involved in this general algorithm are executed in a computer code, developed and run in a C compiler. We propose that, with the help of this code, one can easily compute the numerical solutions of the flow variables such as velocity, pressure, temperature, concentration, streamfunction, vorticityfunction and thereby depict and analyze streamlines, vortex lines, isotherms and isobars, in the driven square cavity for low, moderate and high Reynolds numbers. We have chosen suitable Prandtl and Schmidt numbers that enables us to define the average Nusselt and Sherwood numbers to study the heat ad mass transfer rates from the left wall of the cavity. The stability criterion of the numerical method used for solving the Poisson, vorticity transportation, energy and mass transfer has been given. Based on this criterion, we ought to choose appropriate time and space steps in numerical computations and thereby, we may obtain the desired accurate numerical solutions. The nature of the steady state solutions of the flow variables along the horizontal and vertical lines through the geometric center of the square cavity has been discussed and analyzed. To check the validity of the computer code used and corresponding numerical solutions of the flow variables obtained from this study, we have to compare these with established steady state solutions existing in the literature and they have to be found in good agreement.
Źródło:
Journal of Applied Mathematics and Computational Mechanics; 2018, 17, 3; 17-30
2299-9965
Pojawia się w:
Journal of Applied Mathematics and Computational Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A study on fractional order thermoelastic half space
Autorzy:
Roy, Sourov
Lahiri, Abhijit
Powiązania:
https://bibliotekanauki.pl/articles/1839784.pdf
Data publikacji:
2020
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
termosprężystość
źródło ciepła
transformata Laplace'a
thermoelasticity
instantaneous heat source
fractional order
thermoelastic half space
eigen value approach
Opis:
In this paper, we consider a one dimensional problem on a fractional order generalized thermoelasticity in half space subjected to an instantaneous heat source. The Laplace transform as well as eigen value approach techniques are applied to solve the governing equations of motion and heat conduction. Closed form solutions for displacement, temperature and stress are obtained and presented graphically.
Źródło:
International Journal of Applied Mechanics and Engineering; 2020, 25, 4; 191-202
1734-4492
2353-9003
Pojawia się w:
International Journal of Applied Mechanics and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An environmental aspects of various types of heat sources in a single-family house
Aspekty środowiskowe różnych rodzajów źródeł ciepła w domku jednorodzinnym
Autorzy:
Gużda, Arkadiusz
Szmolke, Norbert
Powiązania:
https://bibliotekanauki.pl/articles/434986.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Opolski
Tematy:
ustainability growth
ecological analysis
heat source for a detached house
environmental aspects
zrównoważony rozwój
analiza ekologiczna
źródło ciepła dla domu jednorodzinnego
aspekty środowiskowe
Opis:
The article evaluates various types of heat source used for heating and ventilation in a typical singlefamily house. Additionally, the paper presents the ecological analysis of the proposed solutions according to The National Centre for Emissions Management (KOBiZE) standards. The analysis was carried out for commonly used heating systems such as a gas boiler with closed combustion chamber, an air-source heat pump (ASHP), a ground source heat pump (GSHP), a coal fired boiler and a wood fired boiler. Moreover, the paper describes the energy performance and energy balance of a typical single-family house. Ultimately, the ecological choice of heating system was presented.
W artykule przeprowadzono analizę emisji zanieczyszczeń przez różne rodzaje źródeł ciepła, wykorzystywanych do ogrzewania i wentylacji dla typowego domku jednorodzinnego. W pracy analiza emisji proponowanych rozwiązań została przeprowadzona zgodnie z standardami Krajowego Ośrodka Bilansowania i Zarządzania Emisjami (KOBiZE). Analizę wykonano dla najczęściej używanych systemów grzewczych w budownictwie mieszkaniowym jednorodzinnym: kotła gazowego z zamknięta komorą spalania, powietrznej i gruntowej pompy ciepła, kotła wodnego opalanego węglem oraz kotła wodnego opalanego drewnem. Ponadto przedstawiono charakterystykę i bilans energetyczny typowego domku jednorodzinnego. Ostatecznie zaproponowano najbardziej ekologiczne rozwiązanie systemu grzewczego dla typowego domku jednorodzinnego.
Źródło:
Economic and Environmental Studies; 2016, 16, 3(39); 349-364
1642-2597
2081-8319
Pojawia się w:
Economic and Environmental Studies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza energetyczna dolnych źródeł ciepła pompy grzewczej przy ogrzewaniu tunelu foliowego
Energy analysis for lower heat sources of heating pump while heating a plastic tunnel
Autorzy:
Kurpaska, S.
Powiązania:
https://bibliotekanauki.pl/articles/291570.pdf
Data publikacji:
2007
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
tunel foliowy
ogrzewanie
górne źródło ciepła
wymienniki gruntowe
moc grzewcza
pompa ciepła
plastic tunnel
heating
ground exchangers
upper heat source
heat pomp
heating power
Opis:
W pracy analizowano wydajność grzewczą dolnego i górnego źródła ciepła współpracujących ze sprężarkową pompą ciepła. Określono zmienność wydajności w funkcji różnicy temperatury między zasilaniem a powrotem czynnika obiegowego. Stwierdzono, że w badanych warunkach analizy cyklów pracy pompy ciepła, konieczna jest modyfikacja odbioru energii z górnego źródła.
The paper contains an analysis of heating efficiency for lower and upper heat sources, which work with compressor-type heat pump. The researchers determined efficiency variability in the function of temperature difference between circulating medium supply and return. It was proved that in the examined conditions of heat pump working cycle analysis it is requisite to modify the system for receiving energy from upper source.
Źródło:
Inżynieria Rolnicza; 2007, R. 11, nr 9 (97), 9 (97); 103-110
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wydajności pionowego wymiennika dolnego źródła pompy ciepła
Analysis of heat pump lower temperature vertical heat exchanger
Autorzy:
Rutkowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/287557.pdf
Data publikacji:
2007
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
pompa ciepła
wymiennik pionowy
źródło dolne
energia
temperatura
heat pump
vertical exchanger
lower source
energy
temperature
Opis:
W pracy przedstawiono analizę energetyczną pionowych wymienników pompy ciepła umieszczonych w gruncie piaszczystym o wysokim poziomie wód gruntowych. Przeprowadzono analizę dwóch typów wymienników wykonanych z rur polietylenowych o średnicy 40 mm ułożonych w gruncie w kształcie pojedynczego i podwójnego U. Określono wydajność cieplną wymienników przy zróżnicowanym zapotrzebowaniu energii. Dla istniejących warunków badań okazało się, że wymienniki w kształcie pojedynczej U-rurki posiadają większą wydajność cieplną w porównaniu z wymiennikami w kształcie podwójnej U-rurki.
The paper presented energy use analysis in heat pump vertical exchangers embedded in sand soil characterized by a high level of subterranean waters. The analysis was conducted for two types of heat exchangers made of polyethylene 40 mm diameter pipes were embedded in the soil, using a pattern of single and double letter "U". Heat efficiency of exchangers was determined at varying energy demand. It appeared that in case of this experiment the exchangers having a shape of a single "U" have higher heat efficiency than those holding the pattern of double "U".
Źródło:
Inżynieria Rolnicza; 2007, R. 11, nr 6 (94), 6 (94); 213-222
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wymagań technicznych i eksploatacyjnych dla budynków przy zasilaniu ze scentralizowanych źródeł ciepła
Autorzy:
Misztal, G.
Ziembicki, P.
Benysek, G.
Kuczyński, T.
Powiązania:
https://bibliotekanauki.pl/articles/160382.pdf
Data publikacji:
2011
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
ogrzewanie
źródło ciepła
ogrzewanie centralne
budynek mieszkalny
wymagania techniczne
OZE
heating
energy source
central heating
residential building
technical requirements
renewable energy source
Źródło:
Przegląd Budowlany; 2011, R. 82, nr 5, 5; 24-28
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Heat Recovery from Wastewater Using a Heat Pump on the Example of a Wastewater Treatment Plant in the Świętokrzyskie Voivodeship in Polish
Analiza odzysku ciepła ze ścieków przy wykorzystaniu pompy ciepła na przykładzie oczyszczalni ścieków województwa świętokrzyskiego
Autorzy:
Kowalik, Robert
Bąk-Patyna, Paulina
Powiązania:
https://bibliotekanauki.pl/articles/2055089.pdf
Data publikacji:
2021
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
heat pumps
heat recovery
waste water as a source of heat pump supply
pompy ciepła
odzysk ciepła
ścieki jako źródło zasilania pomp ciepła
Opis:
Currently, sources from which renewable energy could be generated are being sought worldwide. One of these sources could be wastewater. This article shows how heat can be recovered from wastewater, using a small wastewater treatment plant in Świętokrzyskie voivodeship as an example. It analyses the temperature of wastewater in the reactor, in the sewage system and the ambient temperature for each month. The principle of heat pump operation was presented. Then, the amount of heat energy that can be recovered from wastewater was calculated for each month.
Obecnie na całym świecie poszukuje się źródeł, z których można by wytworzyć energię odnawialną. Jednym z takich czynników mogą być ścieki. W niniejszym artykule przedstawiono, jak można odzyskać ciepło ze ścieków na przykładzie niewielkiej oczyszczalni pracującej na terenie województwa świętokrzyskiego. Dokonano analizy temperatury ścieków znajdujących się w reaktorze, w kanalizacji oraz temperatury otoczenia dla każdego miesiąca. Przedstawiono zasadę działania pomp ciepła. Następnie policzono ilość energii cieplnej, jaka może być odzyskana ze ścieków dla każdego miesiąca.
Źródło:
Structure and Environment; 2021, 13, 3; 90--95
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Artificial Neural Network to the Control of the Parameters of the Heat Treatment Process of Casting
Autorzy:
Wróbel, J.
Kulawik, A.
Bokota, A.
Powiązania:
https://bibliotekanauki.pl/articles/382692.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
heat treatment
moving heat source
artificial neural network
numerical modelling
control system
heating process
obróbka cieplna
źródło ciepła ruchome
sztuczna sieć neuronowa
modelowanie numeryczne
system sterowania
proces nagrzewania
Opis:
In the paper the use of the artificial neural network to the control of the work of heat treating equipment for the long axisymmetric steel elements with variable diameters is presented. It is assumed that the velocity of the heat source is modified in the process and is in real time updated according to the current diameter. The measurement of the diameter is performed at a constant distance from the heat source (Δz = 0). The main task of the model is control the assumed values of temperature at constant parameters of the heat source such as radius and power. Therefore the parameter of the process controlled by the artificial neural network is the velocity of the heat source. The input data of the network are the values of temperature and the radius of the heated element. The learning, testing and validation sets were determined by using the equation of steady heat transfer process with a convective term. To verify the possibilities of the presented algorithm, based on the solve of the unsteady heat conduction with finite element method, a numerical simulation is performed. The calculations confirm the effectiveness of use of the presented solution, in order to obtain for example the constant depth of the heat affected zone for the geometrically variable hardened axisymmetric objects.
Źródło:
Archives of Foundry Engineering; 2015, 15, 1; 119-124
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biomasa jako źródło ciepła w piecach cementowych
Biomass as a source of heat in cement kilns
Autorzy:
Trembacz, J.
Sładeczek, F.
Powiązania:
https://bibliotekanauki.pl/articles/392534.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Ceramiki i Materiałów Budowlanych
Tematy:
źródło energii odnawialne
produkcja cementu
biomasa
źródło ciepła
paliwo alternatywne
renowable energy source
cement manufacturing
biomass
heat source
alternative fuel
Opis:
Omówiono właściwości wybranych paliw alternatywnych i biomasy, wykorzystywanych w piecach cementowych jako źródło ciepła przy współspalaniu z węglem. Wykonano obliczenia symulacyjne współspalania paliw PASr i PASi, przedstawiono bilans cieplny i masowy oraz wpływ współspalania biomasy na wydajność pieca, emisję CO2 oraz pozostałe parametry technologiczne instalacji wypalania klinkieru.
Properties of selected alternative fuels and biomass used as source of heat in co-incineration with hard coal in cement kilns were described. Simulate estimations of heat and mass balance during co- -incineration of fuels PASr and PASi were executed, influence of combustion of biomass fractions on CO2 emission and other technological kiln’s parameters were discussed.
Źródło:
Prace Instytutu Szkła, Ceramiki, Materiałów Ogniotrwałych i Budowlanych; 2009, R. 2, nr 4, 4; 165-175
1899-3230
Pojawia się w:
Prace Instytutu Szkła, Ceramiki, Materiałów Ogniotrwałych i Budowlanych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efektywność sprężarkowej pompy ciepła powietrze-woda po modernizacji układu kierowniczego dolnego źródła ciepła
Efficiency of compressor heat pump (air-water) after modernisation of guiding system for lower heat source
Autorzy:
Knaga, J.
Powiązania:
https://bibliotekanauki.pl/articles/291636.pdf
Data publikacji:
2009
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
energia
pompa ciepła
źródło ciepła
współczynnik efektywności energetycznej
badanie eksploatacyjne
energy
heat pump
heat source
energy efficiency coefficient
performance test
Opis:
W pracy przedstawiono wyniki badań eksploatacyjnych małej sprężarkowej pompy ciepła OW 150 typu powietrze-woda, przeznaczonej do przygotowania ciepłej wody użytkowej, po przeprowadzonej modernizacji układu kierowniczego na dolnym źródle ciepła. Przeprowadzona szczegółowa analiza wyników badań pokazała, iż współczynnik efektywności energetycznej zmienia się w granicach 1,45-3,45 (przy wartości przeciętnej 2,05) w czasie cyklu nagrzewania wody w zasobniku. Ponadto badania prowadzone w warunkach eksploatacyjnych po modernizacji układu kierowniczego dolnego źródła ciepła, wskazują na istotny wzrost efektywności energetycznej o 11% w odniesieniu do badań wstępnych.
The paper presents results of performance tests carried out for small compressor heat pump (OW 150), air-water type, designed for preparing hot utility water, after completed modernisation of guiding system in lower heat source. Detailed analysis of test results has proven that during water heating cycle in water tank the energy efficiency coefficient value ranges from 1.45 to 3.45 (mean value is 2.05). Moreover, tests performed in service conditions after modernisation of lower heat source guiding system indicate significant increase in energy efficiency by 11%, compared to preliminary tests.
Źródło:
Inżynieria Rolnicza; 2009, R. 13, nr 6, 6; 141-147
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of chemical reaction and radiation on double diffusive flow of a viscous, dissipative fluid through porous medium in a rectangular cavity with heat sources
Autorzy:
Raju, T. L.
Muralidhar, P.
Powiązania:
https://bibliotekanauki.pl/articles/955281.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
wymiana ciepła
wymiana masy
promieniowanie
rozproszenie
źródło ciepła
heat and mass transfer flow
radiation
dissipation
heat sources
rectangular cavity
porous medium
Opis:
In this paper, an attempt is made to discuss the combined influence of radiation and dissipation on the convective heat and mass transfer flow of a viscous fluid through a porous medium in a rectangular cavity using the Darcy model. Making use of the incompressibility, the governing non-linear coupled equations for the momentum, energy and diffusion are derived in terms of the non-dimensional stream function, temperature and concentration. The Galerkin finite element analysis with linear triangular elements is used to obtain the global stiffness matrices for the values of stream function, temperature and concentration. These coupled matrices are solved using an iterative procedure and expressions for the stream function, temperature and concentration are obtained as linear combinations of the shape functions. The behavior of temperature, concentration, the Nusselt number and Sherwood number is discussed computationally for different values of the governing parameters, such as the Rayleigh Number (Ra), heat source parameter (α), Eckert number (Ec), Schmidt Number (Sc), Soret parameter (S0), buoyancy ratio (N).
Źródło:
International Journal of Applied Mechanics and Engineering; 2013, 18, 4; 1115-1150
1734-4492
2353-9003
Pojawia się w:
International Journal of Applied Mechanics and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of diffusion and internal heat source on a two-temperature thermoelastic medium with three-phase-lag model
Autorzy:
Othman, M. I.
Said, S. M.
Powiązania:
https://bibliotekanauki.pl/articles/240881.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
diffusion
Green-Naghdi theory
internal heat source
three-phase-lag model
two-temperature
dyfuzja
teoria Greena-Naghdiego
źródło ciepła
Opis:
The purpose of this paper is to depict the effect of diffusion and internal heat source on a two-temperature magneto-thermoelastic medium. The effect of magnetic field on two-temperature thermoelastic medium within the three-phase-lag model and Green-Naghdi theory without energy dissipation i discussed. The analytical method used to obtain the formula of the physical quantities is the normal mode analysis. Numerical results for the field quantities given in the physical domain are illustrated on the graphs. Comparisons are made with results of the two models with and without diffusion as well as the internal heat source and in the absence and presence of a magnetic field.
Źródło:
Archives of Thermodynamics; 2018, 39, 2; 15-39
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effects of heat source/sink and chemical reaction on MHD Maxwell nanofluid flow over a convectively heated exponentially stretching sheet using homotopy analysis method
Autorzy:
Sravanthi, C. S.
Gorla, R. S. R.
Powiązania:
https://bibliotekanauki.pl/articles/265865.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
reakcja chemiczna
źródło ciepła
materiały porowate
HAM
chemical reaction
heat source/sink
Maxwell nanofluid
porous exponentially stretching sheet
convective boundary conditions
Opis:
The aim of this paper is to study the effects of chemical reaction and heat source/sink on a steady MHD (magnetohydrodynamic) two-dimensional mixed convective boundary layer flow of a Maxwell nanofluid over a porous exponentially stretching sheet in the presence of suction/blowing. Convective boundary conditions of temperature and nanoparticle concentration are employed in the formulation. Similarity transformations are used to convert the governing partial differential equations into non-linear ordinary differential equations. The resulting non-linear system has been solved analytically using an efficient technique, namely: the homotopy analysis method (HAM). Expressions for velocity, temperature and nanoparticle concentration fields are developed in series form. Convergence of the constructed solution is verified. A comparison is made with the available results in the literature and our results are in very good agreement with the known results. The obtained results are presented through graphs for several sets of values of the parameters and salient features of the solutions are analyzed. Numerical values of the local skin-friction, Nusselt number and nanoparticle Sherwood number are computed and analyzed.
Źródło:
International Journal of Applied Mechanics and Engineering; 2018, 23, 1; 137-159
1734-4492
2353-9003
Pojawia się w:
International Journal of Applied Mechanics and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evolution of microclimatic conditions in Paskov Mine
Ewolucja warunków mikroklimatycznych w Kopalni Paskov
Autorzy:
Zapletal, P.
Prokop, P.
Kosnovsky, V.
Powiązania:
https://bibliotekanauki.pl/articles/218734.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wentylacja kopalń
warunki klimatyczne
źródło ciepła
urządzenie chłodnicze
mine ventilation
climatic conditions
source of heat
refrigerating unit
Opis:
The main subject of this paper focuses on scientific and research activities conducted in the Institute of Mining Engineering and Safety of the VŠB-Technical University of Ostrava. Cooperation between the VŠB-Technical University of Ostrava and OKD A.S., the only representative of coal mining in the Ostrava-Karviná coal basin, has recently begun to develop again. This paper describes an example discussed in a certain study, which has been undertaken for the Paskov mine, OKD a.s., dealing specifically with the evolution of microclimate parameters in mines that depend on the progress of mining activity at deeper levels over a period of several years. To this end, a special program, aimed at determination of the necessary refrigerating capacity, was established at the VŠB-Technical University of Ostrava.
W związku ze schodzeniem eksploatacji na większe głębokości i pogarszającymi się warunkami klimatycznymi OKD a.s. wystąpiła do VŠB-TU Ostrava, Wydział Górnictwa i Geologii o opracowanie studium pokazującego zmiany warunków mikroklimatycznych w kopalni Paskov w dwóch punktach czasowych oraz o określenie wymaganej mocy urządzeń chłodniczych. Do tego celu w VŠB-TU w Ostrawie opracowano specjalny program komputerowy określający wymagane moce chłodnicze. Na podstawie studium można podjąć decyzję o ewentualnym zamontowaniu centralnej klimatyzacji dla szybu zastępującej dotychczasowe lokalne jednostki chłodnicze. Studium przeprowadzono zgodnie z rozporządzeniem Czeskiego Urzędu Górnictwa nr 22/1989 w sprawie bezpieczeństwa i higieny pracy oraz bezpieczeństwa przy eksploatacji złóż górniczych oraz przy głębinowym wydobyciu surowców mineralnych, zgodnie z rozporządzeniem Czeskiego Urzędu Górnictwa nr 165/2002 w sprawie odrębnych systemów przewietrzenia w przypadku działalności wydobywczej w kopalniach, w których występuje gaz kopalniany oraz zgodne z rozporządzeniem Rady Ministrów nr 361/2007 w sprawie określenia warunków higieny pracy oraz zgodnie z pozostałymi obowiązującymi przepisami. Dla przejrzystości obliczeń zmian warunków mikroklimatycznych na wyrobiskach Kopalni Paskov do badań wybrano rejon przyszłego wydobycia - ściany nr 080 210 oraz drążonego wyrobiska nr 080 5255. Omawiany rejon pokładu 080 (dla przyszłej ściany nr 080 210 oraz eksploatowanego wyrobiska nr 080 5255) znajduje się w posieci wentylacyjnej szybu wylotowego nr II/4 (miejscowość Staříč). Wyrobiska zlokalizowano w odrębnym sektorze wentylacyjnym nr 080 210. W poszczególnych odcinkach zostały zainstalowane punktowe źródła ciepła (szczegóły w artykule) oraz lokalne urządzenia chłodnicze, co zostało przedstawione na rys. 1. Przez zainstalowanie klimatyzatorów lokalnych DV 150 w sieci wentylacyjnej w rejonie poddanym badaniu, tzn. w odrębnym sektorze wentylacyjnym nr 080 210, tj. w chodniku nr 080 5253 przed wlotem do wentylatora lutniowego APXK 630 wentylacji odrębnej drążonego chodnika nr 080 5255 oraz w chodniku nr 080 5253 w bliskim przedpolu ściany nr 080 210 doszło do wyraźnej poprawy warunków mikroklimatycznych dla ściany nr 080 210 oraz w jej chodniku wentylacyjnym (z sześciu przerw z powodu pogorszonych warunków mikroklimatycznych bez zainstalowanych klimatyzatorów lokalnych do stanu bez przerwy po zainstalowaniu klimatyzatorów lokalnych), jak również do poprawy warunków mikroklimatycznych na przodku drążonego chodnika nr 080 5255 przy akceptowalnych warunkach mikroklimatycznych w rejonie odprowadzenia strumienia wentylacyjnego z wyrobiska nr 080 5255 posiadającego wentylację odrębną. Przewidywana moc chłodnicza dla rejonu odrębnego sektora wentylacyjnego 080 210 wynosi 300 kW. Badania wskazały na istotną zależność, zgodnie z którą wraz ze wzrostem głębokości wydobycia pogarszają się warunki mikroklimatyczne w miejscu pracy. W przykładzie opisujemy wyrobisko przewidywane na rok 2012, znajdujące się na granicy eksploatacji podpoziomowej. Na tym przykładzie widać, że bez urządzeń chłodniczych nie byłaby możliwa eksploatacja w tym rejonie. W przypadku eksploatacji podpoziomowej warunki mikroklimatyczne w wielu planowanych wyrobiskach osiągały jeszcze gorsze wskaźniki. Z powyższego wynika ważny wniosek, że z punktu widzenia przepisów bezpieczeństwa i higieny pracy nie jest możliwe prowadzenie prac w takich miejscach bez lokalnych urządzeń chłodniczych lub bez centralnego systemu klimatyzacji.
Źródło:
Archives of Mining Sciences; 2012, 57, 4; 1045-1055
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies