Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Wojciechowski, R. M." wg kryterium: Autor


Wyświetlanie 1-36 z 36
Tytuł:
Analysis and optimisation of an axial flux permanent magnet coreless motor based on the field model using the superposition principle and genetic algorithm
Autorzy:
Wojciechowski, R. M.
Powiązania:
https://bibliotekanauki.pl/articles/140448.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
axial flux permanent magnet motor
Biot-Savart law
finite element analysis
magnetic fields
superposition principle
genetic algorithm
Opis:
In the paper, methodologies for the magnetic field simulation in an axial flux permanent magnet coreless (AFPMC) motor have been proposed and discussed. Two approaches have been considered and investigated, both based on representing the 3D field distribution by superimposing axisymmetric 2D patterns. The first of studied approaches applies directly to the Biot-Savart law while the second uses a 2D axisymmetric finite element method. The selected results of magnetic field distributions and electromagnetic torque characteristics for the considered AFPMC motor have been presented and compared with results obtained using the commercial FEM package 'Maxwell'. The elaborated algorithms have been incorporated into the design routines allowing multi-parameter optimisation of the considered motor construction.
Źródło:
Archives of Electrical Engineering; 2016, 65, 3; 601-611
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza układu bezprzewodowego przesyłu energii z szeregowo-szeregowym obwodem rezonansowym
The analysis of wireless energy transmission system with series–series resonant circuit
Autorzy:
Kurzawa, M.
Wojciechowski, R. M.
Powiązania:
https://bibliotekanauki.pl/articles/376622.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
bezprzewodowa transmisja energii elektrycznej
transformator powietrzny
model obwodowy
Opis:
W artykule przedstawiono obwodowy model układu bezprzewodowego przesyłu energii elektrycznej umożliwiający analizę statycznych i dynamicznych stanów pracy. Rozpatrzono układ złożony z transformatora powietrznego z szeregowo–szeregowym obwodem rezonansowym, elementów obwodu zasilającego i odbiorczego. Przedstawiono równania opisujące rozpatrywany układ bezprzewodowy. Podano warunki doboru pojemności obwodów rezonansowych. W celu rozwiązania równań opisujących rozpatrywany układ bezprzewodowej transmisji energii zastosowano metodę polegającą na dyskretyzacji czasu, tj. metodę kolejnych kroków czasowych (ang. time stepping method) oraz schemat numeryczny z parametrem wagowym. Przeprowadzono analizę stanów pracy układu. Przedstawiono wybrane wyniki obliczeń symulacyjnych.
The paper deals with a circuit model of the wireless energy transmission system allowing the analysis of static and dynamic of the operating conditions. The system consisting of an air transformer with a series–series resonant circuit and the elements of circuits of transmitter and receiver has been considered. The equations of the studied wireless system have been given. The way of selection of capacity for the resonant circuits has been proposed and discussed. In order to solve the equations describing the considered wireless power transmission system the time stepping method and the numerical scheme with weight parameter have been applied. The selected results of simulation have been presented and discussed.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2016, 86; 241-253
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza zjawisk elektromagnetycznych w układach bezprzewodowej transmisji energii elektrycznej z wykorzystaniem polowo-obwodowego modelu
Analysis of electromagnetic phenomena in systems of wireless transmission power using field-circuit model
Autorzy:
Kurzawa, M.
Wojciechowski, R. M.
Powiązania:
https://bibliotekanauki.pl/articles/376482.pdf
Data publikacji:
2018
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
transformator powietrzny
model polowo-obwodowy
bezprzewodowa transmisja energii elektrycznej
Opis:
W artykule omówiono wyniki badań nad analizą układu bezprzewodowego przesyłu energii elektrycznej (UBTE) z bezrdzeniowym transformatorem wysokiej częstotliwości. Na potrzeby obliczeń opracowano polowo-obwodowy model układu w środowisku Maxwell 3D. Rozpatrzono układ składający się z dwóch cewek sprężonych magnetycznie połączonych wspólnie z elementami obwodów zewnętrznych. Przedstawiono wybrane wyniki obliczeń symulacyjnych. Wyniki obliczeń porównano z wynikami pomiarów uzyskanymi na zbudowanym stanowisku laboratoryjnym.
In the paper, the wireless transmission energy system (WTES) using the highfrequency air-transformer has been discussed and investigated. The considered system consists of two magnetically coupled coils, which have been connected to the elements of external circuits. To analyze the electromagnetic field and to define the parameters of the considered system the field-circuit model has been elaborated in the Maxwell environment. In order to verify the calculation results obtained in the field-circuit model the experimental setup has been developed. The results of simulation calculations have been compared with the measurements obtained in the experimental setup.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2018, 93; 355-365
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Polowa analiza silnika indukcyjnego o masywnym wirniku hybrydowym
The field analysis of induction motor with a solid hybrid rotor
Autorzy:
Wojciechowski, R. M.
Walkowiak, S.
Powiązania:
https://bibliotekanauki.pl/articles/376086.pdf
Data publikacji:
2012
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
silnik indukcyjny
masywny wirnik hybrydowy
polowa analiza silnika indukcyjnego
Opis:
W artykule przedstawiono wyniki polowej analizy silnika indukcyjnego o masywnym wirniku hybrydowym. W rozpatrywanej konstrukcji zastosowano stojan istniejącego silnika indukcyjnego klatkowego, a fabryczny wirnik zastąpiono masywnym wirnikiem hybrydowym dwuwarstwowym. Rdzeń wirnika wykonano z proszkowego materiału kompozytowego (SMC) typu Somaloy 500, na powierzchni którego umieszczono cylindryczną tuleję z materiału przewodzącego. W badaniach autorzy skoncentrowali się przede wszystkim na analizie wpływu zmian grubości warstwy przewodzącej 5 wirnika na rozkład pola elektromagnetycznego i parametrów funkcjonalnych silnika. Obliczenia wykonano w oprogramowaniu wykorzystującym dwuwymiarowe ujęcie metody elementów skończonych w połączeniu z metodą potencjału zespolonego.
In the paper the results of field analysis of the induction motor with a solid hybrid rotor have been presented. The stator construction has been based on the existing induction motor, in which a classical squirrel-cage rotor has been replaced with a solid hybrid rotor. In considered motor the hybrid rotor consist of a magnetic core made of soft magnetic composite material Somaloy 500 and a conductive layer made of aluminum. In the investigations, authors concentrated primarily on the change influence of conductive layer thickness 8 of rotor on the electromagnetic field distributions and functional parameters in considered motor. The calculations have been performed using the 2D FEM software, in which the complex potential vector A has been applied. The selected results of analysis are compared and discussed.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2012, 72; 157-166
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Układ bezprzewodowej transmisji energii elektrycznej z szeregowo-równoległym obwodem rezonansowym współpracujący z mostkowym falownikiem napięcia
The system of wireless power transmission containing the serial-parallel resonant circuit in cooperation with the bridge voltage inverter
Autorzy:
Kurzawa, M.
Wojciechowski, R. M.
Powiązania:
https://bibliotekanauki.pl/articles/376166.pdf
Data publikacji:
2017
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
bezprzewodowa transmisja energii elektrycznej
model symulacyjny
mostkowy falownik napięcia
transformator powietrzny
układ rezonansowy
Opis:
W artykule przedstawiono układ bezprzewodowej transmisji energii elektrycznej (UBTE) współpracujący z mostkowym falownikiem napięcia. Rozpatrzono układ z szeregowo-równoległym połączeniem kondensatorów kompensujących. Omówiono sposób doboru optymalnych wartości pojemności rezonansowych oraz rezystancji obciążenia. Do wyznaczania optymalnych wartości pojemności i rezystancji obciążenia opracowano autorską aplikację. Na potrzeby obliczeń projektowych rozpatrywanego układu opracowano model symulacyjny, który zaimplementowano w środowisku Matlab. Przedstawiono wybrane wyniki obliczeń symulacyjnych. Zbudowano układ falownika mostkowego pracującego w UBTE. Przeprowadzono weryfikację wyników obliczeń z wynikami pomiarów.
In the paper the system of wireless power transmission (UBTE) cooperated with a full H-bridge inverter has been presented. The serial-parallel connection of compensating capacitors has been considered. The way of selection of optimal values of resonant capacitances and value of load resistance has been discussed. The software to determination of the optimal values of capacitances and load resistance has been elaborated in Visual Studio C# environment. For the design calculations, the simulation model of the UBTE connected with inverter has been developed. The model has been implemented in Matlab environment. The selected results of calculations have been presented. Based on the obtained calculation results, the bridge inverter cooperated with TP has been designed and elaboreted. Finally, the verification of calculation results with measurement results has been conducted.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2017, 90; 301-312
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Projekt stanowiska laboratoryjnego do wizualizacji przebiegów siły elektromotorycznej transformacji
Design of the experimental setup to visualization of waveforms of the transformation electromotive force
Autorzy:
Kurzawa, M.
Wojciechowski, R. M.
Powiązania:
https://bibliotekanauki.pl/articles/376799.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
siła elektromotoryczna transformacji
zjawisko indukcji elektromagnetycznej
Prawo Faraday'a
stanowisko laboratoryjne
Opis:
W artykule przedstawiono projekt stanowiska laboratoryjnego do wizualizacji przebiegów siły elektromotorycznej transformacji. Projektując obwód elektromagnetyczny stanowiska wykorzystano specjalistyczne oprogramowanie do polowej analizy zjawisk Maxwell, w którym zaimplementowano popularną metodę elementów skończonych (MES). Projekt konstrukcji mechanicznej wykonano natomiast w oprogramowaniu AutoDesk Inwentor Professional. Następnie stanowisko laboratoryjne zbudowano i przeprowadzono rejestrację przebiegów siły elektromotorycznej transformacji. Wyniki obliczeń symulacyjnych uzyskane w programie Maxwell porównano z wynikami pomiarów uzyskanymi na stanowisku.
The paper presents the design of the experimental setup to visualization of waveforms of the transformation electromotive force. The project calculations of the electromagnetic circuit have been performed in program Maxwell using Finite Element Method (FEM). The concept of the construction of the experimental setup has been elaborated in the software of AutoDesk company. The experimental setup has been built and tested. The results of simulation calculations obtained in the Maxwell software have compared with the measurements obtained in the experimental setup.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2014, 77; 201-208
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza zjawisk elektromagnetycznych w układzie bezprzewodowego przesyłu energii
The analysis of electromagnetic phenomena in the system of wireless power transmission
Autorzy:
Kurzawa, M.
Wojciechowski, R. M.
Powiązania:
https://bibliotekanauki.pl/articles/377838.pdf
Data publikacji:
2015
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
bezprzewodowa transmisja energii
transformator powietrzny
Opis:
W artykule przedstawiono wyniki polowej analizy zjawisk elektromagnetycznych zachodzących w układzie bezprzewodowej transmisji energii elektrycznej (WREL). Rozpatrzono transformator powietrzny złożony z dwóch sprzężonych cewek połączonych z elementami obwodów zewnętrznych. Model polowo-obwodowy rozpatrywanego układu opracowano w profesjonalnym oprogramowaniu Maxwell, w którym zaimplementowano popularną metodę elementów skończonych (MES). Utworzony 3D model transformatora łącznie z równaniami obwodów elektrycznych umożliwia wykreślenie trójwymiarowego rozkładu pola, wyznaczenie wartości parametrów całkowych i przebiegów prądów oraz napięć na poszczególnych elementach składowych układu. W pracy zbadano wpływ odległości pomiędzy cewkami oraz częstotliwości źródła zasilania na wartość sprawności układu. Przedstawiono wybrane wyniki obliczeń.
In the paper, the results of a field analysis of electromagnetic phenomena in the system of the wireless power transmission (WREL) have been discussed and presented. The considered airtransformer consists of two coupled coils connected to the elements of external circuits. The fieldcircuit model of considered system has been developed in a professional Maxwell software, in which a popular finite element method (FEM) has been employed. The elaborated 3D model of the transformer together with external circuit allows to determining of the three-dimensional distributions of the electromagnetic field, defining of the integral parameters and plotting of the waveforms of currents and voltages on elements of external circuits. In the work the influence of the distance between the coils of air-transformer and the frequency of the power source of the value system efficiency have been studied. The selected results of the calculations have been given.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2015, 81; 79-86
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A description of the sources of magnetic field using edge values of the current vector potential
Autorzy:
Wojciechowski, R. M.
Jędryczka, C.
Powiązania:
https://bibliotekanauki.pl/articles/140898.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
numerical modeling
edge element analysis
current vector potential T0
stranded windings
Opis:
The paper discusses the method of a description of the magnetic field sources in systems with the stranded windings. The sources are determined on the basis of an obtained distribution of edge values of the current vector potential T0. The formulas describing the magnetic field sources in the finite element (FE) space for the formulations using the scalar potential F and the vector potential A have been given. The approach for determining the T0 distribution in the stranded windings of simple and complex geometries has been proposed.
Źródło:
Archives of Electrical Engineering; 2018, 67, 1; 17-26
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Inwerter klasy E w układzie bezprzewodowego przesyłu mocy – aplikacja do projektowania, obliczenia symulacyjne
Inverter E-class in system of wireless power transfer design software, simulation calculation
Autorzy:
Rybicki, K.
Wojciechowski, R. M.
Powiązania:
https://bibliotekanauki.pl/articles/377122.pdf
Data publikacji:
2017
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
bezprzewodowy przesył energii elektrycznej
falownik rezonansowy klasy E
transformator powietrzny
model obwodowy
Matlab
Opis:
W artykule przedstawiono układ bezprzewodowego przesyłu energii elektrycznej (UBTE) złożony z: transformatora powietrznego, obwodu zasilania (inwertera klasy E) oraz obwodu odbiorczego. Rozpatrzono układ z szeregowo-szeregowym i szeregoworównoległym połączeniem kondensatorów kompensujących. Zaproponowano metodę doboru wartości parametrów układu z myślą o wykorzystaniu istniejących cewek powietrznych. Do potrzeb projektowania inwerterów klasy E w układach bezprzewodowego przesyłu energii opracowano specjalistyczne oprogramowanie (aplikację) w środowisku Matlab-Simulink. Przeprowadzono analizę wpływu wybranych parametrów układu na ustalony stan pracy. Przedstawiono wybrane wyniki obliczeń symulacyjnych.
The paper present equivalent model of wireless power transfer composed of: air– transformer, power supply circuit (class E inverter) and load circuit. Series–series and series–parallel resonant circuit has been considered. The method of parameter value selection with the aim of using exist air coils has been proposed. Impedance reflections of way from secondary to the primary circuit have been explained. Graphical user interface of application integrated with equivalent model in order to design E class inverters in the wireless energy transmission have been realized and presented. The selected results of simulation have been presented and discussed.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2017, 91; 263-275
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Polowo-obwodowy model osiowosymetrycznego aktuatora liniowego
The field-circuit model of axis-symmetrical linear actuator
Autorzy:
Mikołajewicz, J.
Wojciechowski, R. M.
Powiązania:
https://bibliotekanauki.pl/articles/1367685.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
Model polowo-obwodowy
aktuator liniowy
analiza numeryczna
Field-circuit model
linear actuator
numerical analysis
Opis:
In the paper a field-circuit model of axis-symmetrical linear actuator has been presented. An actuator with conical armature has been considered and investigated. The integral parameters of the model, such as the inductance and the force have been determined on the basis of 2D electromagnetic field distributions, which have been obtained for the field model. Then, the calculated parameters have been implemented to the circuit model, ie. the model of the system comprising the coupled equations of the electrical circuit and the mechanical equilibrium equation of the considered actuator. In the considerations, the eddy current effect has not been taken account. The selected results of simulations have been presented.
W artykule przedstawiono polowy-obwodowy model osiowosymetrycznego aktuatora liniowego. Rozpatrywano aktuator nurnikowy z nurem stożkowym. Parametry całkowe modelu, takie jak indukcyjność oraz siła, zostały wyznaczone na podstawie rozkładu dwuwymiarowego pola magnetycznego. Obliczone parametry skupione następnie zaimplementowano w modelu obwodowym przetwornika, tzn. modelu obejmującym układ sprzężonych równań obwodu elektrycznego oraz równania dynamiki. W rozważaniach pominięto tłumiący charakter prądów wirowych. Przedstawiono wybrane wyniki badań symulacyjnych.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2015, 3, 107; 173-177
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Aplikacja mobilna wspomagająca badania ultrasonograficzne Dopplera
Mobile application supporting Doppler ultrasound examination
Autorzy:
Michalski, M.
Bąkała, M.
Wojciechowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/408402.pdf
Data publikacji:
2017
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
ultrasonografia
diagnostyka
aplikacja mobilna
ultrasonography
diagnostics
mobile application
Opis:
Ultrasonografia Dopplerowska jest jednym z najlepszych sposobów diagnozy zmian miażdżycowych oraz szczegółowej kontroli patologii zmian ścian naczyń krwionośnych. Wykonanie badania wymaga szeregu czynności wykonywanych współbieżnie, m.in. analizy obrazów USG oraz ręcznego sporządzania notatek na potrzeby podsumowania badania. Analiza problemu wykazała, że przebieg badań ultrasonograficznych może zostać częściowo zautomatyzowany przez dedykowane oprogramowanie, co przedstawia niniejszy artykuł.
Doppler ultrasonography is one of the best ways of diagnosing the atherosclerosis and inspecting the details of the vessel wall pathology. Carrying out the examination requires plenty of activities that have to be done simultaneously, i.a. analysing the USG images and manually taking notes to the examination report. The analysis of the problem enables stating that the Doppler ultrasound examination can be partially automated with the aid of dedicated software system, what is the point of the article.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2017, 7, 3; 64-67
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena aktualnego stanu zabezpieczenia KWB Turów w aspekcie zdarzeń powodziowych zaistniałych w sierpniu 2010 r.
Evaluation of the current state of protection against flood hazards in the Turów open pit brown coal mine after the disastrous flood in August 2010
Autorzy:
Salata, R.
Sondaj, L.
Wojciechowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/394127.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
niecka żytawska
kopalnia Turów
zagrożenia powodziowe
powódź błyskawiczna
rozmycia erozyjne
osuwiska
akcja ratunkowa
szkody
obszary zalewowe
działania naprawcze
zwałowanie
zabezpieczenia na filarze rzeki Nysy Łużyckiej
zabezpieczenia na filarze rzeki Miedzianki i potoku Ślad
monitoring zagrożeń wodnych
Zittau (Żytawa) Basin
flash flood
pillar of the Nysa Łużycka River and Miedzianka River
flood hazard
landslides
rescue action
damages
flooded areas
recovering flooding coal seams
dumping
embankments against flowing water from the Nysa River
Miedzianka River
Ślad brook
monitoring
Opis:
W referacie przedstawiono działania podjęte przez KWB Turów, dotyczące zabezpieczenia odkrywki przed wdarciem się wód wezbraniowych z cieków zewnętrznych otaczających odkrywkę oraz zabezpieczenia przed zagrożeniami, jakie niosą ze sobą opady nawalne. W dniach 7-8 sierpnia 2010 r. wystąpiły nawalne opady deszczu w Górach Izerskich, obejmujące terytorium Czech i Polski. Niezwykle silny opad spowodował bardzo szybko postępującą w czasie powódź błyskawiczną. Ilość wody, jaka spadła w ciągu doby, wynosiła około 150 litrów/m2. W otoczeniu KWB Turów wystąpiły z koryt trzy rzeki: Nysa Łużycka, Miedzianka i Witka, które spływały z ogromną prędkością do obszaru Niecki Żytawskiej. Rzeka Miedzianka spowodowała klęskę powodziowąw Bogatyni. Zostały zniszczone drogi, mosty oraz kilkadziesiąt budynków. Na zboczu wschodnim wyrobiska, na filarze rzeki Miedzianki, woda spowodowała rozmycie nasypu kolejowego na długości około 80 m i wdarła się na teren zakładu górniczego, doprowadzając do przerwania głównych ciągów przenośnikowych i komunikacyjnych. Wody pochodzące z opadów oraz wody, które wdarły się do wyrobiska z rzeki Miedzianki, spowodowały konieczność wstrzymania ruchu zakładu górniczego w dniach 7-8 sierpnia 2010 r. Woda zalała dwa najniższe poziomy eksploatacyjne i jeden poziom zwałowy. Na spągu wyrobiska powstały dwa obszary zalewowe. Nysa Łużycka, będąca rzeką graniczną z Niemcami, spowodowała powódź w miejscowości Porajów i Sieniawka. Na zachodnim zboczu odkrywki, na filarze Nysy Łużyckiej, powstało zagrożenie przerwania wałów przeciwpowodziowych. W aspekcie zdarzeń powodziowych z sierpnia 2010 r. Kopalnia Turów stanęła przed koniecznością przeanalizowania i dokonania oceny stanu zabezpieczenia odkrywki przed dopływem wód z zewnątrz i opracowania działań zabezpieczających na kolejne lata. Odtworzono i podwyższono wały ziemne zlokalizowane pomiędzy terenem odkrywki KWB Turów a rzeką Miedzianką, potokiem Ślad oraz na filarze rzeki Nysa Łużycka na przepływ miarodajny Qm05% (t.j. na opad 200-letni). Natomiast trzy miejsca wykazane jako miejsca niebezpieczne - gdzie nastąpiło wtargnięcie wód z rzek zewnętrznych - będą wymagały dodatkowego specjalnego zabezpieczenia wg projektu technicznego: podwyższenia wałów ziemnych na przepływ Qk01%, tj. na opad 1000-letni.
This paper describes protective actions taken against the flood hazard in the open pit mine KWB Turów. Rivers and brooks surrounding the Turów open pit mine create a substantial hazard of water breaking through embankments and destroying the infrastructure of the mine. This paper shows the causes and results of the disastrous flood in August 2010. On the 7th-8th of August 2010, torrential rains occurred in the Izera Mountains on the territory of the Czech Republic and Poland. Heavy rain caused immediate and unusual flooding. These mountains are the source of all the rivers surrounding the Turów mine, including the Nysa Łużycka, Miedzianka, and Witka Rivers. Great amounts of water (totalling 150 billion litres over the course of 24 hours) flowing from the north sides of the mountains caused a flash flood resulting in natural disasters in Bogatynia, Porajów, and Sieniawka, destroying urban infrastructure and tens of historic buildings. On the pillar of the east side of the mine, water broke through the embankments and rushed into the open pit mine of Turów. The mine was forced to cease operations. Water flooded the bottom of the open pit and two working levels. On the west side of the mine, water from the overflowing Nysa Łużycka threatened to destroy the west embankments. Water broke through the dam on the Witka River, and 60 million m3 severed the only route between Bogatynia and the rest of Poland. This report describes the rescue and the liquidation action, recovering the flooded coal seams, and preventative actions taken against flooding. The damaged embankment and railroad were rebuilt, and the Miedzianka River cleaned. Protective embankments along the Ślad brook were extended. They reconstructed embankments located between the area of the Turów mine and the Miedzianka River and also on the pillar of the Nysa Łużycka River against two-hundred-year flood. However, three dangerous locations were indicated where the forced entry of water resulted from outside rivers - requiring additional reinforcement efforts according to the technical plan in order to raise the earth embankments higher to account for the one-thousand-year flood.
Źródło:
Zeszyty Naukowe Instytutu Gospodarki Surowcami Mineralnymi i Energią PAN; 2012, 82; 157-172
2080-0819
Pojawia się w:
Zeszyty Naukowe Instytutu Gospodarki Surowcami Mineralnymi i Energią PAN
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Polowy model transformatora powietrznego z uzwojeniami spiralnymi w układzie bezprzewodowego przesyłu energii
Field model of air -core transformer with spiral windings in wireless resonant energy link
Autorzy:
Łyskawiński, W.
Kurzawa, M.
Wojciechowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/377171.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
transformator powietrzny
model polowy
bezprzewodowy przesył energii
Opis:
W artykule przedstawiono polowy model transformatora powietrznego pracującego w układzie bezprzewodowego przesyłu energii. Zaprezentowano algorytm rozwiązywania równań modelu metodą elementów skończonych (MES). Na podstawie zaprezentowanego algorytmu opracowano program do wyznaczania nieustalonego pola magnetycznego. Przedstawiono wybrane wyniki symulacji.
In the paper the field model of air-core transformer operating in a wireless resonant energy link has been presented and discussed. The proposed algorithm for solving the model equations using finite element method has been given. On the basis of the proposed algorithm the in-house software has been developed for determining the transient magnetic field. The selected results have been presented.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2016, 85; 255-265
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tunneling Charge Transport in Graphene-Based Superconductor Junctions
Autorzy:
Wojciechowski, R.
Kowalewski, L.
Nogala, M.
Powiązania:
https://bibliotekanauki.pl/articles/1427098.pdf
Data publikacji:
2012-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
74.45.+c
72.80.Vp
72.25.-b
Opis:
We study the spin polarized electron and hole tunneling transport through a graphene-based ferromagnet$(GF_1)$-insulator$(GI_1)$-superconductor$(G_{S})$-insulator$(GI_2)$-ferromagnet$(GF_2)$ junction. Proximity induced spin polarization and superconductivity in a graphene sheet are assumed to be created by superconducting and ferromagnetic electrodes placed on the top of the graphene. Using a four-dimensional version of the Dirac-Bogoliubov-de Gennes equation with appropriate boundary conditions we investigate the tunneling processes through the junctions. In particular, we present calculations of the amplitudes of normal and Andreev reflections as a function of the energy of the incident electron for a wide range of the model parameters, such as the strength and orientation of the exchange field, the barrier strength, and the distance between the two ferromagnetic layers. The tunneling transport processes in the graphene-based double junction GF/GI/$G_{S}$/GI/GF are compared with those in non-graphene-based junctions.
Źródło:
Acta Physica Polonica A; 2012, 121, 5-6; 1092-1094
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza skuteczności wprowadzonego systemu wsparcia wytwarzania energii elektrycznej z metanu
Analysis of the effectiveness of implemented systems of support for generating electricity from methane
Autorzy:
Kaliski, M.
Wojciechowski, R.
Szurlej, A.
Powiązania:
https://bibliotekanauki.pl/articles/282376.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
metan z pokładów węgla
zasoby metanu
system wsparcia
gospodarcze wykorzystanie metanu z kopalń
coal bed methane
methane resources
system of support
commercial utilization of methane
Opis:
W artykule dokonano przeglądu zasobów metanu z kopalń w Polsce oraz sposobów zagospodarowania tego gazu. Scharakteryzowano system wsparcia oraz przedstawiono podstawowe informacje o jego funkcjonowaniu w latach 2010-2011 r. Dokonana została uproszczona analiza ekonomiczna działającego systemu oraz przedstawiono rekomendacje. Ustawą z dnia 8 stycznia 2010 r. o zmianie ustawy - Prawo energetyczne oraz o zmianie niektórych innych ustaw wprowadzono system wsparcia w postaci świadectw pochodzenia energii elektrycznej wytworzonej w wysokosprawnej kogeneracji w jednostce opalanej metanem uwalnianym i ujmowanym przy dołowych robotach górniczych w czynnych, likwidowanych lub zlikwidowanych kopalniach węgla kamiennego. Istniejące obecnie w Polsce mechanizmy wsparcia dla produkcji energii elektrycznej z metanu, pochodzącego z kopalń węgla kamiennego są niewystarczające. Stworzony w 2010 r. system wsparcia w postaci świadectw oraz udzielanie pomocy publicznej przeznaczonej na inwestycje budowy nowych lub przystosowania istniej?cych instalacji energetycznych do wykorzystywania metanu pochodz?cego z odmetanowania kopalń węgla kamiennego nie zachęcają do zwiększenia gospodarczego wykorzystania metanu. W wyniku przeprowadzonej analizy wynika, iż należałoby: oprzeć system wsparcia na zasadach takich, jak dla systemu wsparcia odnawialnych źródeł energii (OZE), bez konieczności produkcji energii w kogeneracji, zwiększyć wartość opłaty zastępczej stosowanej w obecnym systemie wsparcia, stworzyć system wsparcia dla utylizacji i zagospodarowania metanu wentylacyjnego. Stosowane aktualnie technologie odmetanowania powodują, że metan uwalniany w trakcie robót górniczych jest w około 30% ujmowany odmetanowaniem, a w 70% usuwany na drodze wentylacyjnej. Możliwe jest zwiększenie poziomu odmetanowania z zastosowaniem obecnych technologii wydobycia węgla, czyli uj?cie 60% metanu i wyemitowanie do atmosfery 40%. Po wprowadzeniu zmian w systemie wsparcia obserwowany będzie znacz?cy efekt ekologiczny związany z zagospodarowaniem metanu.
This paper presents a review of coal mine methane resources in Poland and methods of their utilization. It characterizes the support system and presents principle information concerning the system’s functioning in the years 2010–2011. Basic economic analysis of existing systems was performed, and recommendations are presented. Based on the law dated January 8th 2010 – Energy law and changes of selected other acts certain support system based on the certificates of electrical energy origin generated in the highly efficient cogeneration in the unit fired with methane released and captured during underground mining works in operating, under liquidation or already closed hard coal mines was introduced. The mechanisms to support the production of electrical energy from coal mine methane already existing in Poland are not sufficient. The support system created in 2010 using certificates and public support meant for the construction of new, or adjustments to existing, energy installations to utilize methane coming from the drainage systems of hard coal mines fail to encourage increasing economical utilization of coal mine methane. The conclusions from the above analysis suggest that it is recommendable to: have existing support systems rely on the same rules as for the system of renewable sources of energy, without the necessity to produce energy in cogeneration, increase the supplementary fee used in the present support system, create a support system for the capturing and utilization of ventilation air methane. The technologies presently used to drain coal mine methane released during mining exploitation enable the capture of only 30% of the gas. The remaining 70% is released into the atmosphere. It is possible to increase the efficiency of methane drainage up to as much as 60% when implementing the latest drainage technologies mitigating methane emissions down to 40%. The introduction of the suggested changes in the support system should result in a significant ecological effect from coal mine methane’s economical utilization.
Źródło:
Polityka Energetyczna; 2012, 15, 4; 57-69
1429-6675
Pojawia się w:
Polityka Energetyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zagospodarowanie metanu z pokładów węgla - stan obecny i perspektywy
Commercial Development of Coal Bed Methane - current situation and prospects
Autorzy:
Kaliski, M.
Wojciechowski, R.
Szurlej, A.
Powiązania:
https://bibliotekanauki.pl/articles/283140.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
niekonwencjonalne złoża gazu ziemnego
metan z pokładów węgla
zasoby metanu
węgiel kamienny
unconventional gas resources
coal bed methane (CBM)
methane resources
hard coal
Opis:
W artykule dokonano przeglądu doświadczeń krajowych w zagospodarowaniu metanu z pokładów węgla w latach 2002-2012 oraz przeanalizowano rozwój wykorzystania tego gazu w USA i Australii. Za wyborem tych państw przemawia odpowiednio skala oraz rozwój dynamiki wydobycia, a także plany Australii w zakresie eksportu metanu poprzez jego upłynnianie (LNG). Pozostałymi państwami wydobywającymi metan z pokładów węgla na skalę przemysłową są Chiny, Kanada oraz Indie. Ze względu na sposób pozyskania metanu z węgla wyróżnia się kilka rodzajów tego gazu i dla usystematyzowania zestawiono ich nazwy oraz wskazano różnice pomiędzy nimi. Dokonano przeglądu zasobów metanu z pokładów węgla w Polsce na tle zasobów światowych oraz przybliżono sposoby zagospodarowania tego gazu oraz rozwój technologii zagospodarowania. Przenalizowano zależność pomiędzy metanowością bezwzględną a poziomem wydobycia węgla kamiennego w Polsce oraz poziom zużycia metanu do produkcji energii elektrycznej i ciepła. JSW ma największe doświadczenia w zakresie energetycznego wykorzystania metanu. Przybliżono także doświadczenia pozostałych spółek węglowych w zagospodarowaniu metanu (KW i KHW). Oceniono rozwój zagospodarowania metanu z pokładów węgla z punktu widzenia systemu wsparcia wprowadzonego ustawą z dnia 8 stycznia 2010 r. o zmianie ustawy - Prawo energetyczne oraz o zmianie niektórych innych ustaw. W podsumowaniu przywołano doświadczenia amerykańskich koncernów naftowych sprzed około dwudziestu lat w zakresie zagospodarowania metanu, które wówczas nie zakończyły się sukcesem. Dlatego też niezbędne są kolejne badania i współpraca przedsiębiorstw, świata nauki i wsparcie ze strony państwa.
This paper provides an overview of national experiences in developing coal bed methane over the years 2002-2012, and analyses the development of its utilisation in the US and Australia. The choice of these countries was supported by their scale of methane production and the development of production dynamics, as well as Australia's plans to export methane through its liquefaction (LNG). The remaining countries producing methane from coal beds on an industrial scale are China, Canada, and India. This paper arranges by name and characterizes the features of several types of methane recovered from coal. It reviews coal bed methane resources in Poland and compares these to global resources. The paper also presents techniques of gas development as well as their technological advancements. Also analysed is the relationship between the total volume of methane and the level of hard coal production in Poland, in addition to the amount of methane consumption used to produce electricity and heat. The mining firm JSW has the most experience in utilising methane for energy production. Other mining companies are also presented with details on their experience in the commercial development of methane (KW and KHW). Advances in coal bed methane utilisation have been estimated according to the support system introduced by the Act of January 8, 2010 on amending the Energy Law and on amending certain other acts. The summary considers the experiences of US oil companies over the past twenty years in terms of methane extraction which proved unsuccessful. It is therefore necessary to carry out further research and develop cooperation between companies and the scientific world, as well as to receive government support.
Źródło:
Polityka Energetyczna; 2013, 16, 4; 189-200
1429-6675
Pojawia się w:
Polityka Energetyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Heavy Fermion Superconductor Order Parameter in High Magnetic Field
Autorzy:
Kowalewski, L.
Wojciechowski, R.
Thomas, M.
Nogala, M.
Powiązania:
https://bibliotekanauki.pl/articles/1930573.pdf
Data publikacji:
1994-02
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
74.70.Tx
74.60.-w
74.90.+n
Opis:
It is shown that, independently on either the nature and the strength of pairing, the orbital effects of a high magnetic field in heavy fermion superconductor change the form of both the effective pairing and the gap function.
Źródło:
Acta Physica Polonica A; 1994, 85, 2; 347-350
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fractional discrete model of an electrical drive with brushless micro-motor
Autorzy:
Matusiak, M.
Bąkała, M.
Wojciechowski, R.
Ostalczyk, P.
Powiązania:
https://bibliotekanauki.pl/articles/200454.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
system modeling
system identification
fractional order calculus
Opis:
The use of fractional-order calculus for system modeling is a good alternative to well-known classic integer-order methods, primarily due to the precision with which the modeled object may be mapped. In this study, we created integer and fractional discrete models of a real object – a highspeed brushless micro-motor. The accuracy of the models was verified and compared.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2020, 68, 3; 421-427
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Unconventional Superconductivity in Strong Magnetic Field
Autorzy:
Kowalewski, L.
Nogala, M. M.
Thomas, M.
Wojciechowski, R. J.
Powiązania:
https://bibliotekanauki.pl/articles/1955830.pdf
Data publikacji:
1997-02
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
74.60.-w
74.62.-c
71.70.Di
74.20.Fg
Opis:
The Landau quantization effects are considered in low carrier concentration unconventional spin triplet p-wave superconductors in a high magnetic field region. The field dependence of the superconducting order parameter and the vortex lattice states for intra Landau level pairing are analyzed. The gap functions are calculated within mean field approximation.
Źródło:
Acta Physica Polonica A; 1997, 91, 2; 395-398
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analizy i badania nośności stalowych słupów rurowych linii elektroenergetycznych
Autorzy:
Lewiński, P.
Czyż, R.
Wojciechowski, P.
Otręba, M.
Powiązania:
https://bibliotekanauki.pl/articles/162089.pdf
Data publikacji:
2010
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
linia elektroenergetyczna
słup trakcyjny
słup stalowy
słup rurowy
analiza nośności
electric line
traction pole
steel pole
pipe pole
bearing capacity analysis
Źródło:
Przegląd Budowlany; 2010, R. 81, nr 5, 5; 83-86
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mapping of the DFT Spin Configuration Energies of Cr8Cd Molecular Ring onto the Energy Structure of Falicov-Kimball Model
Autorzy:
Wojciechowski, M.
Brzostowski, B.
Lemański, R.
Kamieniarz, G.
Powiązania:
https://bibliotekanauki.pl/articles/1386266.pdf
Data publikacji:
2015-02
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
75.50.Xx
71.15.Mb
73.22.-f
75.30.Et
31.15.E-
71.10.-w
Opis:
A comprehensive study of electronic and magnetic properties of a recently synthesized nonametalic chromium-based heteronuclear molecule Cr₈CdF₉(O₂C-C(CH₃)₃)₁₈ is presented, using DFT and Falicov-Kimball (FK) model approach. The magnetic moments are calculated and the spin charge density map is discussed. The exchange coupling parameters between transition metals ions are extracted, taking into account all the nonequivalent spin configurations. It is demonstrated that the energies of the spin configurations can be reproduced by the FK model with a set of parameters consistent with that for the parent Cr8 molecule. For molecular ring considered, the ground state corresponds to the antiferromagnetic configuration and the ferromagnetic configuration yields the highest energy.
Źródło:
Acta Physica Polonica A; 2015, 127, 2; 410-412
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tunneling Current into the Vortex Lattice States of s- and p-Wave Superconductors
Autorzy:
Kowalewski, L.
Nogala, M. M.
Thomas, M.
Wojciechowski, R. J.
Powiązania:
https://bibliotekanauki.pl/articles/2012910.pdf
Data publikacji:
2000-01
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
74.50.+r
74.60.-w
71.70.Di
Opis:
The tunneling current between the metallic tip of a scanning microscope and s-wave and p-wave superconductors in a quantizing magnetic field is investigated. The differential conductance is calculated both as a function of bias voltage at the centre of the vortex line and for varying position of the scanning tunneling microscope tip at a stable voltage.
Źródło:
Acta Physica Polonica A; 2000, 97, 1; 237-240
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Semi-Automatic Apparatus for Measuring Wetting Properties at High Temperatures
Autorzy:
Bąkała, M.
Wojciechowski, R.
Sankowski, D.
Rylski, A.
Powiązania:
https://bibliotekanauki.pl/articles/220997.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
surface tension
wetting angle
wetting force
measurement system
Opis:
Determination of the physico-chemical interactions between liquid and solid substances is a key technological factor in many industrial processes in metallurgy, electronics or the aviation industry, where technological processes are based on soldering/brazing technologies. Understanding of the bonding process, reactions between materials and their dynamics enables to make research on new materials and joining technologies, as well as to optimise and compare the existing ones. The paper focuses on a wetting force measurement method and its practical implementation in a laboratory stand – an integrated platform for automatic wetting force measurement at high temperatures. As an example of using the laboratory stand, an analysis of Ag addition to Cu-based brazes, including measurement of the wetting force and the wetting angle, is presented.
Źródło:
Metrology and Measurement Systems; 2017, 24, 1; 175-184
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Anomalous Phase Transitions in $LiCsSO_4$ in the Compressible hcp Ising Model
Autorzy:
Lehmann-Szweykowska, A.
Kurzyński, M.
Wojciechowski, R.
Wiesner, M.
Mróz, B.
Powiązania:
https://bibliotekanauki.pl/articles/1427164.pdf
Data publikacji:
2012-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
78.35.+c
75.10.Hk
62.20.D-
Opis:
Structural low-temperature phase transformations in $LiCsSO_4$ are analysed in a newly tailored simple model of the static soliton in the periodically modulated phases of the one-dimensional compressible Ising model. It is shown that the original hcp symmetry is crucial for understanding of the anomalous temperature-dependence of the Brillouin shift.
Źródło:
Acta Physica Polonica A; 2012, 121, 5-6; 1108-1110
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ultrasonografia dopplerowska i jej zastosowanie w reumatologii
Doppler ultrasonography and its application in rheumatology
Autorzy:
Jeka, S.
Żuchowski, P.
Wojciechowski, R.
Sokólska, E.
Dura, M.
Powiązania:
https://bibliotekanauki.pl/articles/261967.pdf
Data publikacji:
2012
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
Doppler mocy
błona maziowa
power Doppler
colour Doppler
synovial membrane
Opis:
W ostatnich latach obserwuje się znaczny postęp w jakości obrazowania ultrasonograficznego, a wykorzystanie tej metody w codziennej praktyce klinicznej jest coraz bardziej powszechne. Wraz z rozwojem aparatów ultrasonograficznych USG (Ultrasonography) na znaczeniu zyskały opcje od dawna dostępne w badaniu ultrasonograficznym, takie jak: kolor Doppler (CD – Color Doppler) oraz Doppler mocy (PD – Power Doppler). Możliwości szerszego zastosowania tych metod wymagają ponownej oceny ich zalet oraz ograniczeń. Ograniczenia opcji CD wynikają z modelu fizycznego, jaki opisuje zjawisko Dopplera. Nieznajomość tego modelu może prowadzić do błędnego wykonania i interpretacji wyników badania. Istotna jest zatem znajomość korelacji między kątem, pod jakim wykonywane jest badanie, a mierzoną prędkością przepływu krwi. Można przyjąć mylne założenie, że opcja PD w porównaniu z CD jest rzadziej stosowana, ponieważ dostarcza mniej informacji na temat przepływu krwi. W praktyce okazuje się jednak, że są dziedziny diagnostyki medycznej, w których opcja PD ma bardzo szerokie zastosowanie i odgrywa znacznie ważniejszą rolę niż CD, np. podczas badania stawów w reumatologii. Ostatecznie o przydatności badania metodą Dopplera decyduje wiedza badającego, która umożliwia wybranie odpowiedniej opcji i przeprowadzenie poprawnego badania w zależności od potrzeb.
In recent years, the significant progress was made in the improvement of the quality of ultrasound imaging what contributes to its frequent application in everyday clinical practice. Along with the development of ultrasound devices, the options available in ultrasound examinations: Color Doppler (CD) and Power Doppler (PD), gained in importanceimportance. The potential and possibilities of a wider application of these methods need a reevaluation of their merits and limitations. Limitations of the CD option result from a physical model which is described by the Doppler effect. Unfamiliarity with this model may lead to a wrong performance and interpretation of the test’s results. Therefore, it is important to know a correlation between an angle at which the test is performed and measured speed of a blood flow. One can take the wrong assumption that the PD option in comparison to the CD option is less applicable, as it provides much less information about the blood flow. In practice, it turned out that there are areas of medical diagnostics, in which the PD option is widely used and plays more important role than the CD option, e.g. when assessing joints in rheumatology. The usefulness of Doppler method is determined by the knowledge of the investigator, which allows to select the appropriate option and perform the correct tests, depending on needs.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2012, 18, 2; 83-87
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Properties of the Semi Spin Glass Ground State of Garnets
Autorzy:
Koper, A.
Lehmann-Szweykowska, A.
Thomas, M.
Wojciechowski, R. J.
Powiązania:
https://bibliotekanauki.pl/articles/1861316.pdf
Data publikacji:
1994-01
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
75.10.Hk
75.50.Bb
81.30.Bx
Opis:
A strong magnetic ordering response to valence-uncompensated doping observed experimentally in yttrium iron garnet, indicates the importance of a thorough analysis of the problem. Within the framework of the classical two-sublattice Heisenberg model the position on the ground state phase diagram, corresponding to the experimentally found values of the superexchange parameters of yttrium iron garnet, turns out to lie close to the semi spin glass region. Thus, in this paper, the magnetic structure factor, the spectrum of magnetic excitations, the density of states and a magnetic contribution to the specific heat, are calculated and discussed.
Źródło:
Acta Physica Polonica A; 1994, 85, 1; 233-236
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu liczby i rozmieszczenia prętów uzwojenia rozruchowego na wybrane parametry funkcjonalne silnika synchronicznego magnetoelektrycznego
The influence analysis of number and arrangements bars of permanent magnet synchronous motor on the functional parameters
Autorzy:
Barański, M.
Kowalski, K.
Łyskawiński, W.
Stachowiak, D.
Wojciechowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/1367667.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
silnik synchroniczny o rozruchu bezpośrednim
parametry funkcjonalne
analiza numeryczna
Line start permanent magnet synchronous motor
functional parameters
numerical analysis
Opis:
The paper presents an analysis of the impact of the number and distribution of the rotor cage bars of the line start permanent magnet synchronous motor (LSPMSM) on the values of the functional parameters and the waveforms of the electromagnetic torque and the rotational speed. The calculations have been performer using the field model developed in the Maxwell Entertainment. The 6-pole of LSPMSM, with the magnets arranged in the U-shaped, has been considered. The design solution has been discussed and presented, which achieves a small torque ripple and good functional parameters.
W artykule przedstawiono analizę wpływu liczby i rozmieszczenia w wirniku prętów uzwojenia klatkowego silnika synchronicznego magnetoelektrycznego przystosowanego do rozruchu bezpośredniego (LSPMSM) na jego parametry funkcjonalne. Badania przeprowadzono przy wykorzystaniu polowoobwodowego modelu silnika opracowanego w programie Maxwell. Rozpatrzono 6-cio biegunowy silnik o wirniku z magnesami trwałymi ułożonymi w obszarze podziałki biegunowej w kształcie litery U. Badano wpływ sposobu rozmieszczenia i liczby prętów uzwojenia klatkowego na przebiegi momentu elektromagnetycznego, prędkości obrotowej, sprawność i na współczynnik mocy silnika. Przedstawiono rozwiązanie konstrukcyjne, dla którego uzyskuje się małe pulsacje momentu oraz bardzo dobre parametry funkcjonalne.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2015, 3, 107; 25-30
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
DFT and Falicov-Kimball Model Approach to $Cr_{9}$ Molecular Ring
Autorzy:
Brzostowski, B.
Wojciechowski, M.
Lemański, R.
Kamieniarz, G.
Timco, G.
Tuna, F.
Winpenny, R.
Powiązania:
https://bibliotekanauki.pl/articles/1368686.pdf
Data publikacji:
2014-07
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
75.50.Xx
71.15.Mb
73.22.-f
75.30.Et
Opis:
Based on density functional theory (DFT) calculations, we present electronic and magnetic properties of nanometallic homo-nuclear chromium-based molecular rings $Cr_{9}F_{9}Cl_{2}(O_{2}C-C(CH_{3})_{3})_{17}$ recently synthesized. The magnetic moments are calculated, the spin density maps are discussed and the exchange interaction parameter is extracted. The complementary studies are carried out using the Falicov-Kimball model which reproduces very well the energy levels determined by different magnetic broken symmetry configurations obtained by DFT.
Źródło:
Acta Physica Polonica A; 2014, 126, 1; 270-271
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Examination of Wetting by Liquid Zinc of Steel Sheets Following Various Kinds of Abrasive Blasting
Autorzy:
Cecotka, M.
Dybowski, K.
Klimek, L.
Lipa, S.
Rylski, A.
Sankowski, D.
Wojciechowski, R.
Bąkała, M.
Powiązania:
https://bibliotekanauki.pl/articles/352820.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
abrasive blasting
dip zinc coating
surface preparation
wettability
Opis:
Abrasive blasting is one of the methods of surface working before hot-dip zinc-coating. It allows not only to remove products of corrosion from the surface, but it also affects the quality of the zinc coating applied later, thereby affecting wettability of surface being zinc-coated. The surface working can be done with different types of abrasive material. The paper presents an effect of the method of abrasive blasting on wetting the surface of steel sheets by liquid zinc. Steels sheets following blasting with Al2O3 of different granularity and shot peening were examined. The worst wetting was recorded for a sample following shot peening - the results are below those for the reference test conducted for a sample not previously subjected to any treatment. Samples following abrasive blasting have similar parameters, regardless of the size of grain used for the treatment.
Źródło:
Archives of Metallurgy and Materials; 2016, 61, 2B; 1069-1074
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie zwilżania ciekłym cynkiem blach stalowych po obróbce plastycznej
Investigations of liquid zinc wetting of steel sheets after plastic treatment
Autorzy:
Klimek, L.
Lipa, S.
Dybowski, K.
Atraszkiewicz, R.
Rylski, A.
Sankowski, D.
Wojciechowski, R.
Bąkała, M.
Powiązania:
https://bibliotekanauki.pl/articles/212208.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Obróbki Plastycznej
Tematy:
obróbka plastyczna
walcowanie blach
cynkowanie zanurzeniowe
przygotowanie powierzchni
zwilżalność
plastic treatment
sheet rolling
hot dip zinc coatings
surface preparation
wettability
Opis:
Niniejsza praca powstała w ramach realizacji projektu badawczego mającego na celu opracowanie i wdrożenie technologii recyklingu poprodukcyjnych odpadów taśmy stalowej. W ramach prowadzonych prac wykonano procesy oczyszczania blach metodami obróbki strumieniowo-ściernej, a następnie tak oczyszczone blachy poddawano procesowi walcowania. Po procesie walcowania nakładano, metodą zanurzeniową, powłokę cynkową. W pracy przedstawiono wpływ gniotu podczas obróbki plastycznej na zwilżanie powierzchni blach stalowych ciekłym cynkiem. Badaniom poddano blachy obrobione ścierniwem Al2O3, które zostały potem poddane walcowaniu z różnymi gniotami (20, 40, 60 i 80%). Na tak przygotowanych próbkach przeprowadzono badania na specjalnie zaprojektowanym stanowisku dynamiki zwilżania metodą meniskograficzną umożliwiającą wykonanie kompleksowych badań własności dynamicznych powierzchni – napięcia powierzchniowego oraz zwilżalności. Z przeprowadzonych badań wynika, że najlepsza zwilżalność osiągana jest dla próbek o gniocie 20%, dla których graniczny kąt zwilżania wynosi ok. 60°. Im większy gniot, tym gorsza zwilżalność blach stalowych ciekłym cynkiem. Można zauważyć, że jeszcze tylko dla próbki z gniotem 40% zarejestrowano kąt zwilżania poniżej 90° (wynosił on około 80°). Można powiedzieć, że tylko te próbki były zwilżane ciekłym cynkiem. Dla pozostałych dwóch zarejestrowane wartości kąta zwilżania były znacznie powyżej 90° przyjętych, jako granica przejścia z braku zwilżania do zwilżania. Reasumując uzyskane wyniki badań, można stwierdzić, że zwiększenie stopnia zgniotu podczas procesu walcowania zmniejsza zwilżalność obrobionej powierzchni ciekłym cynkiem.
This paper was elaborated within a research project aiming at the development and implementation of a recycling technology for post-production steel sheet waste. In the research, processes of sheet cleaning were performed by vapour blasting treatment methods. Next, the sheets cleaned in this way underwent rolling. After the rolling process, a zinc coating was applied by means of the wetting balance method. The study presents the effect of the draft during plastic treatment on the wetting on the surface of steel sheets by liquid zinc. The tests were conducted on sheets treated with an Al2O3 abrasive material, which then underwent rolling with different drafts (20, 40, 60 and 80%). The samples prepared in this way were examined on a specially designed test station for the wetting dynamics by the meniscographic method, which enables complex examinations of the dynamic properties of the surface – surface tension and wettability. The performed investigations demonstrated that the best wettability is obtained for the samples with the 20% draft, for which the contact angle equals about 60°. The higher the draft, the worse the wettability of the sheets by liquid steel zinc. One can notice that the sample with the 40% draft was only one more to exhibit the wetting angle below 90° (it equaled about 80°). One can say that only these samples were wetted by the liquid zinc. For the remaining two, the recorded wetting angle values were much above 90°, which was assumed as the boundary of transfer from no wettability to wettability. To sum up, the obtained results demonstrate that the increase of the draft degree during the rolling process decreases the wettability of the treated surface by liquid zinc.
Źródło:
Obróbka Plastyczna Metali; 2016, 27, 4; 315-328
0867-2628
Pojawia się w:
Obróbka Plastyczna Metali
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of American guidelines for field triage and Polish criteria as qualification to a trauma center
Autorzy:
Nowakowski, J.
Nowakowski, R.
Biliński, P.
Nowak, B.
Wojciechowski, P.
Dworzyński, M.
Golis-Gucwa, M.
Timler, W.
Timler, M.
Timler, D.
Powiązania:
https://bibliotekanauki.pl/articles/2085003.pdf
Data publikacji:
2019
Wydawca:
Instytut Medycyny Wsi
Tematy:
trauma
guidelines
decision making
emergency medical services
EMS
injury
triage
ISS
multiple organ injuries
trauma center
Opis:
Introduction. Trauma is the third cause of death among the general population in Poland, and the first in people aged 1–44 years. Trauma centers are hospitals dedicated to treating patients with multiple organ injuries, in a complex way that endeavours to ensure a lower mortality rate, shorter hospital stay and better outcomes if the patients are transferred to such a center. Worldwide, there are many models on how to treat a trauma patient, but them to be qualified for the procedure, the selection of potential patients is crucial. Objective. The aim of the study was to compare the Polish model for qualification to a trauma center and American Guidelines for Field Triage. Materials and method. Retrospective analysis of medical documentation recorded between 1 January 2014 – 31 December 2014 was undertaken. The study concerned trauma patients admitted to the Emergency Department of the Regional Trauma Center at the Copernicus Memorial Hospital in Łódź, Poland. Inclusion criterion was initial diagnosis ‘multiple-organ injury’ among patients transported by the Emergency Medical Service (EMS). Results. In the period indicated, 3,173 patients were admitted to the Emergency Department at the Copernicus Memorial Hospital. From among them, 159 patients were included in the study. Only 13.2% of the patients fulfilled the Polish Qualification Criteria to Trauma Center in comparison to 87.4% who fulfilled the American Guidelines for Field Triage. Conclusions. Polish qualification criteria do not consider the large group of patients with severe injuries (ISS>15), but indicate patients with minimal chance of survival. Polish criteria do not consider the mechanism of injury, which is a relevant predictive indicator of severe or extremely severe injuries (ISS>15). Further studies should be undertaken to improve the qualification and treatment of trauma patients in Poland.
Źródło:
Annals of Agricultural and Environmental Medicine; 2019, 26, 3; 479-482
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Atomic Force Microscopy Study of a Voltage Effect on CdZnTe Crystal Dimensions
Autorzy:
Aleszkiewicz, P.
Wojciechowski, T.
Fronc, K.
Kolkovsky, V.
Janik, E.
Jakieła, R.
Mycielski, A.
Karczewski, G.
Aleszkiewicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/1811911.pdf
Data publikacji:
2008-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
73.40.Ns
73.61.Ga
77.90.+k
Opis:
In this work we studied the influence of an external electric voltage on spatial dimensions of CdZnTe mixed crystals. In order to get an absolute magnitude of the sample thickness and to gain insight to the changes of lateral dimension, in quasi-bulk 3 μm thick CdZnTe layers grown by molecular beam epitaxy square craters were formed by ion sputtering in a secondary ion mass spectrometer. The vertical and lateral dimensions of the craters were studied by the atomic force microscopy. The atomic force microscopy measurement revealed that the thickness of the CdZnTe layer increases in a result of applying a single voltage pulse to the sample surface and decreases reversibly after applying reversely biased voltage. The voltage triggering was high enough to switch the conductivity state of the sample i.e., the effect of thickness change is accompanied by the effect of conductivity switching. The thickness change is significant, reaching several percents of the entire layer thickness.
Źródło:
Acta Physica Polonica A; 2008, 114, 5; 1041-1047
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Community Traffic: a technology for the next generation car navigation
Autorzy:
Dembczyński, K.
Gaweł, P.
Jaszkiewicz, A.
Kotłowski, W.
Kubiak, M.
Susmaga, R.
Wesołek, P.
Wojciechowski, A.
Zielniewicz, P.
Powiązania:
https://bibliotekanauki.pl/articles/205706.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Instytut Badań Systemowych PAN
Tematy:
community traffic
satellite car navigation
reliability analysis
travel time prediction
Opis:
The paper presents the NaviExpert’s Community Traffic technology, an interactive, community–based car navigation system. Using data collected from its users, Community Traffic offers services unattainable to earlier systems. On the one hand, the current traffic data are used to recommend the best routes in the navigation phase, during which many potentially unpredictable traffic-delaying and traffic-jamming events, like unexpected roadworks, road accidents, or diversions, can be taken into account and thereby successfully avoided. On the other hand, a number of istinctive features, like immediate location of various traffic dangers, are offered. Using exclusively real-life data, provided by NaviExpert, the paper presents two illustrative case studies concerned with experimental evaluation of solutions to computational problems related to the community-based services offered by the system.
Źródło:
Control and Cybernetics; 2012, 41, 4; 867-883
0324-8569
Pojawia się w:
Control and Cybernetics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis and glycosyl composition of the exopolysaccharide isolated from submerged fermentation of Ganoderma lucidum CG144
Autorzy:
Rubel, R.
Freire dos Santos, L.
Stutz Dalla Santa, H.
Porto de Souza Vandenberghe, L.
Wojciechowski, A.L.
de Carvalho, J.C.
Habu, S.
Destefanis Vitola, F.M.
Augur, C.
Soccol, C.R.
Powiązania:
https://bibliotekanauki.pl/articles/56735.pdf
Data publikacji:
2014
Wydawca:
Polskie Towarzystwo Botaniczne
Tematy:
glycosyl composition
exopolysaccharide
isolation
submerged fermentation
Ganoderma lucidum
heteroglycan
herbal medicine
Chinese medicine
Opis:
The evaluation of glycosyl composition is an essential step to guide future research designs applied in bioactivity. In the same way, the unexplored potential bioactivity of exopolysaccharide from Ganoderma lucidum is huge. Therefore, this study investigated the glycosyl composition of the exopolysaccharide isolated from submerged fermentation of G. lucidum to serve as guide for future studies on bioactivity. Glycosyl content and composition were evaluated by combined GC/ MS of the TMS derivatives of the monosaccharide methyl glycosides produced from the sample by acidic methanolysis. Glycosyl composition analysis showed that the dominant carbohydrate component in all samples of exopolysaccharide isolated from submerged fermentation of G. lucidum CG 144 was glucose (58.1%), mannose (26.6%) and galactose (12.5%) which can be referred to as heteroglycan. These results suggest that this Ganoderma exopolysaccharide may be a new immunomodulatory agent.
Źródło:
Acta Societatis Botanicorum Poloniae; 2014, 83, 3
0001-6977
2083-9480
Pojawia się w:
Acta Societatis Botanicorum Poloniae
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-36 z 36

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies