Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Tian, Q." wg kryterium: Autor


Wyświetlanie 1-5 z 5
Tytuł:
Thermally induced damage in hexanitrohexaazaisowurtzitane
Autorzy:
Tian, Q.
Yan, G.
Sun, G.
Huang, C.
Xie, L.
Chen, B.
Huang, M.
Li, H.
Liu, X.
Wang, J.
Powiązania:
https://bibliotekanauki.pl/articles/358735.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Przemysłu Organicznego
Tematy:
CL-20
SAXS
AFM
thermal effects
voids
Opis:
The evolution of the microstructure of hexanitrohexaazaisowurtzitane (CL-20) after a thermal stimulus plays a key role in the performance of CL-20. In the current work, microstructural variations of CL-20 caused by thermal treatment were investigated by X-ray diffraction, in situ variable-temperature optical microscopy, atom force microscopy, and small-angle X-ray scattering. A wave-like process, an abrupt volume expansion, movement, and fragmentation of CL-20 particles during phase transition were observed. After the phase transition (160 °C) the CL-20 sample acquired a very rough surface with numerous dimple depressions, and during the thermal decomposition stage (200 °C) a large number of voids were produced in both the bulk and the surface of the CL-20.
Źródło:
Central European Journal of Energetic Materials; 2013, 10, 3; 359-369
1733-7178
Pojawia się w:
Central European Journal of Energetic Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Microstructural Evolution in HMX Based Plastic-bonded Explosive During Heating and Cooling Process: an in situ Small-angle Scattering Study
Autorzy:
Yan, G.
Tian, Q.
Liu, J.
Fan, Z.
Sun, G.
Zhang, C.
Wang, Y.
Chen, B.
Gong, J.
Zhou, X.
Yang, Z.
Nie, F.
Li, J.
Li, X.
Powiązania:
https://bibliotekanauki.pl/articles/358618.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Przemysłu Organicznego
Tematy:
SANS
SAXS
HMX-PBX
thermal damages
phase transition
Opis:
The thermal damage in octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) based plastic-bonded explosive (PBX) was investigated using in situ small-angle neutron and X-ray scattering techniques. The microstructural evolution was quantitatively characterized by the model fitting parameters of total interfacial surface area (Sv) and void volume distribution. The Sv of HMX-PBX decreased markedly above 100 °C, indicating the movement of binder into the voids. After subsequent cooling to room temperature, the scattering intensity increased significantly with increasing storage time, and a new population of voids with average diameter of 20 nm was observed, accompanied by the gradual phase transition of HMX from δ- to β-phase. The experimental results implied that serious damage within the HMX-PBX was developed during storage after heating.
Źródło:
Central European Journal of Energetic Materials; 2016, 13, 4; 916-926
1733-7178
Pojawia się w:
Central European Journal of Energetic Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
System for Calibrating Analogue Merging Units in Absence of Synchronization Signals
Autorzy:
Cheng, H.-M.
Huang, Q.-F.
Ji, F.
Xu, Q.
Liu, J.
Tian, Z.
Powiązania:
https://bibliotekanauki.pl/articles/221084.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
intelligent substation
analogue merging unit
peer-to-peer communication
calibration system
synchronization signal
Opis:
Synchronization signals are requisite for calibrating electrical measurement devices with digital output when using conventional calibration methods. However, since the signal sampling process of the analogue merging units (MUs) operating in an intelligent substation does not rely on external synchronization signals, accuracy calibration without the use of synchronization signals is of particular importance in order to guarantee the measurement accuracy in practical situations. So far, very little research on calibration systems independent of synchronization signals has been performed. This paper presents a design of the calibration system without dependence on synchronization signals. To verify the feasibility of the proposed design, the designed system and a conventional calibration system have been employed in testing the accuracy of the same analogue MU of a 0.2 accuracy class. The comparison of the test results shows that the differences of ratio errors are below 0.02%, and the maximum difference of phase errors is about 4′. This paper also provides a new efficient and significant calibration method which does not require any external synchronization signals.
Źródło:
Metrology and Measurement Systems; 2018, 25, 1; 129-138
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The off-design performance prediction of axial compressor based on a 2D approach
Autorzy:
Zhu, X. C.
Hu, J. F.
Ou-Yang, H.
Tian, J.
Qiang, X. Q.
Du, Z. H.
Powiązania:
https://bibliotekanauki.pl/articles/281612.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
two-dimensional
compressor
streamline curvature
deviation
loss model
Opis:
The two-dimensional compressor flow simulation approach has always been a very valuable tool in compressor preliminary design studies, as well as performance predictions. In this context, a general development of the streamline curvature (SLC) method is elucidated firstly. Then a numerical method based on SLC is developed to simulate the internal flow of the compressor according to the development analysis and conclusion. Two certain transonic axial compressors are calculated by this 2D method. The speed lines and span-wise aerodynamic parameters are compared with the experiment data in order to demonstrate the method presented in this paper.
Źródło:
Journal of Theoretical and Applied Mechanics; 2013, 51, 3; 523-531
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The unsteadiness of tip clearance flow and its effect to stability of transonic axial compressor
Nieustaloność przepływu w szczelinie wierzchołkowej i jej wpływ na stabilność pracy przydźwiękowej sprężarki osiowej
Autorzy:
Hu, J. F.
Zhu, X. C.
Ou-Yang, H.
Tian, J.
Wu, Y. D.
Qiang, X. Q.
Zhao, G.
Du, Z. H.
Powiązania:
https://bibliotekanauki.pl/articles/281445.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
tip leakage flow
compressor
stability
Opis:
The steady and unsteady RANS simulations of a transonic compressor rotor (NASA rotor 37) are performed to investigate the tip clearance flow characteristic and correlations between tip leakage flow and compressor stability. For steady simulations, the results are compared with the aerodynamic probe and laser anemometer data. The speed lines and span-wise aerodynamic parameters agree well with the experimental data. On the other hand, the tip clearance flow of unsteady simulations are analysed clearly at a near stall condition. The results show that there is a mass flow rate boundary. The tip clearance flow oscillates substantially with a frequency about 50% BPF when the mass is less than that, which is caused by tip clearance flow, shock, and the interaction between them and the oncoming flow. The interface between the oncoming flow and clearance flow shifts forward, and the tip clearance flow may spill over into the adjacent blade passage as the mass flow decreases, which may results in the spike stall inception.
W pracy przedstawiono symulacje stanu ustalonego i nieustalonego przydźwiękowej sprężarki osiowej (turbina NASA 37) z zastosowaniem metody Reynoldsa uśredniania równań Naviera-Stokesa (RANS) w celu zbadania charakterystyki przepływu w szczelinie wierzchołkowej oraz określenia zależności pomiędzy stratami związanymi z upływem w tej szczelinie a stabilnością pracy sprężarki. Wyniki symulacji stanu ustalonego porównano z danymi doświadczalnymi uzyskanymi za pomocą sondy aerodynamicznej i laserowego wiatromierza. Wyznaczone wzdłuż rozpiętości sprężarki linie prędkości przepływu i jego parametry aerodynamiczne okazały się zgodne z danymi doświadczalnymi. W przypadku symulacji stanu nieustalonego, analizę przepływu w szczelinie wierzchołkowej przeprowadzono dla warunków bliskich oderwania, tj. utraty wydajności sprężarki, wyznaczając graniczny wydatek przepływu dla takiej sytuacji. Poniżej tej granicznej wartości, zmiany przepływu w szczelinie oscylują z częstotliwością sięgającą 50% częstotliwości przejścia łopatek (tzw. BPF), co jest konsekwencją interakcji wywołanej zderzeniem przepływu z falą napływową w szczelinie wierzchołkowej. Powierzchnia tej interakcji przesuwa się do przodu, a sam przepływ może rozpaść się na fragmenty znajdujące ujście w kanałach przyległych łopatek. Zjawisko to zachodzi przy malejącym wydatku, a to z kolei może indukować oderwanie przepływu skokowymi zmianami mocy współpracującego silnika.
Źródło:
Journal of Theoretical and Applied Mechanics; 2013, 51, 2; 431-438
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies