Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Sidorowicz, A." wg kryterium: Autor


Wyświetlanie 1-5 z 5
Tytuł:
Electrical Conductivity of Ethylene Glycol Based Nanofluids with Different Types of Thulium Oxide Nanoparticles
Autorzy:
Fal, J.
Sidorowicz, A.
Żyła, G.
Powiązania:
https://bibliotekanauki.pl/articles/1032395.pdf
Data publikacji:
2017-07
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
74.25.F-
72.15.Cz
72.60.+g
73.63.-b
Opis:
The paper presents experimental investigation on electrical conductivity of thulium oxides-ethylene glycol (Tm₂O₃-EG) nanofluids based on nanoparticles with three different sizes, and prepared in different conditions. Nanofluids were prepared with two-step method with use of the nanoparticles obtained by precipitation method. Measurements were conducted at constant temperature 293.15 K for various mass concentrations from 0% to 20% with 5% step. The electrical conductivity was measured using conductivity meter MultiLine 3410 (WTW GmBH, Weilheim, Germany) and temperature was stabilized in a water bath MLL 547 (AJL Electronic, Cracow, Poland). The results indicate that increase in mass concentration of nanoparticles in base fluid causes increase in electrical conductivity of Tm₂O₃-EG nanofluids. The enhancement in electrical conductivity of nanosuspensions of thulium oxide is dependent on particle size.
Źródło:
Acta Physica Polonica A; 2017, 132, 1; 146-148
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bilans magnezu i siarki u młodego bydła opasowego żywionego kiszonkami z kukurydzy
Balans magnija i sery u molodogo otkormochnogo skota kormimogo kukuruznym silosom
Magnesium and sulphur balances in young cattle fed maize silage
Autorzy:
Seidler, S.A.
Wojciechowski, R.
Sidorowicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/798089.pdf
Data publikacji:
1988
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Opis:
В соответствующих исследованиях определяли баланс магния и серы у откормочного скота кормимого силосами изготовленными из монокультурной кукурузы следующих гибридов: Буковиньски-3 выведенного в СССР, французского ИНРА-190 и польских ИХАР-280 и Кб-280. Содержание анализируемых элементов в силосах изготовленных из кукурузных гибридов было высоким, составляя в среднем 0,59 г Мg /кг и 0,66 г S /кг. Исследуемые гибриды кукурузы как источник определенных минеральных элементов не показывали статистически существенных различий и обеспечивали потребности животных в магние, чего проявлением может служить положительный баланс этого элемента и его содержание в моче, составляющее в среднем 103,95 мгМg/л. Полученные отрицательные, или положительные но очень низкие балансы серы показывают, что этот элемент, содержится в преобладающем большинстве кормов в неусвояемом виде. Таким образом возникает необходимость пополнения рационов для откормочного скота содержимого на кукурузных силосах более легко усвояемыми источниками серы.
The magnesium and sulphur balances in young beef cattle fed with the following monocultured maize silages: Bukowiriski-3 bred in USSR, INRA-190 obtained in France, and two Polish hybrids IHAR-280 and Kb-280, were determined. The contents of the above mentioned elements in hybrid maize silages were very high and a- mounted 0,59 g Mg/kg and 0,66 g S/kg. Statististically, there were no great differences in the hybrid maize silages as sources of particular mineral components, and they met cattle requirement for magnesium. The positive magnesium balance and its content of 103,95 mg Mg/1 in urine gave a sufficient evidence. Negative or very low positive sulphur balances showed that the investigated feedstuffs contained that element predominantly in an unavailable form. Therefore, it is necessary to supply beef cattle rations that are based on maize silage with easy available sulphur sources.
Źródło:
Zeszyty Problemowe Postępów Nauk Rolniczych; 1988, 350
0084-5477
Pojawia się w:
Zeszyty Problemowe Postępów Nauk Rolniczych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Właściwości fizyczne nanoproszków Al2O3-Ag wytworzonych metodą rozkładu termicznego-redukcji oraz impregnacji nanosrebrem koloidalnym
Physical properties of Al2O3-Ag nanopowders produced by thermal decomposition-reduction and colloidal nanosilver impregnation
Autorzy:
Sidorowicz, A.
Jastrzębska, A.
Olszyna, A.
Kunicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/192236.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Materiałów Elektronicznych
Tematy:
nanoproszki Al2O3-Ag
Al2O3-Ag nanopowders
Opis:
Praca miała na celu zbadanie wpływu warunków wytwarzania nanoproszków Al2O3-Ag jak również ilości dodanego srebra na ich właściwości fizyczne [1]. Nanoproszki Al2O3-Ag zostały wytworzone metodą rozkładu termicznego-redukcji. W pierwszym etapie otrzymany prekursor poddano wygrzewaniu w temperaturze 700°C w atmosferze powietrza przez 24 h. Następnie, produkt pośredni Al2O3-Ag2O poddano redukcji w temperaturze 700°C w atmosferze wodoru przez 2 h w celu uzyskania produktu końcowego- nanoproszku Al2O3-Ag. Metoda ta pozwoliła na otrzymanie serii próbek A12O3+ x wag% Ag (x = 0.30, 1.35, 2.84, i 12.55). W celach porównawczych wytworzono również nanoproszki Al2O3-Ag metodą impregnacji nanoproszku Al2O3 nanosrebrem z układu koloidalnego nanosrebro-heksan. Metodą tą otrzymano serię próbek Al2O3+ x wag% Ag (x=0.30, l.40, 2.85, oraz 12.70). Otrzymane nanoproszki Al2O3-Ag poddano analizie takich parametrów fizycznych jak powierzchnia właściwa, objętość i rozmiar porów, a także gęstość rzeczywista. Produkty obu metod charakteryzują się znacznie rozwiniętą powierzchnią właściwą (ponad 200 m²/g) oraz dużą objętością porów (0,4-1,1cm³/g).
The main aim of this work was to investigate the influence of Al2O3-Ag production parameters and Ag percentage addition on surface morphology and physical properties of the middle as well as final product. The Al2O3-Ag nanopowders were produced by two methods. The first one, thermal decomposition-reduction allowed receiving the series of samples: Al2O3+ x wt% Ag (x=0.30, 1.35, 2.84, and 12.55). The second, was colloidal nanosilver-hexane impregnation. This method allowed receiving the series of samples: Al2O3+ x wt% Ag (x = 0.30, 1.40, 2.85, and 12.70). Morphology and physical properties were examined using scanning electron microscope, nitrogen sorption measurements and helium pycnometer. Both methods allow to obtain Al2O3-Ag nanopowders with comparable average particle size (between 40 and 100 nm), large specific BET surface area (over 200 m²/g) and large open porosity volume (between 0.4 -1.1 cm³/g).
Źródło:
Materiały Elektroniczne; 2010, T. 38, nr 2, 2; 30-38
0209-0058
Pojawia się w:
Materiały Elektroniczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of ceramic preforms to the manufacturing of ceramic-metal composites
Zastosowanie preform ceramicznych do wytwarzania kompozytów ceramika-metal
Autorzy:
Jach, K.
Pietrzak, K.
Wajler, A.
Sidorowicz, A.
Brykała, U.
Powiązania:
https://bibliotekanauki.pl/articles/352613.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ceramic preform
composite
copper
sintering
preforma ceramiczna
kompozyty
miedź
spiekanie
Opis:
This paper presents new solution to manufacturing Cu-Al2O3 composites with a dispersed reinforcement phase. It consists in substituting commonly used commercial alumina powder with crushed ceramic foam. Very low strength of thin-walled Al2O3 porous foams results in both their easy destruction and isolation of fragments <200 μm. The addition of the ceramic phase is 3-10 vol.%. The sintering process is performed for 30 min in a hot-press at 1050°C and 30 MPa. The aim of the presented paper is to study the effect of the volume content of the ceramic phase on the microstructure and selected physical and thermal properties of copper - alumina composites.
Artykuł przedstawia nowatorskie rozwiązanie wytwarzania kompozytów Cu-Al2O3 z rozproszoną fazą wzmacniającą. Polega ono na wykorzystaniu zamiast powszechnie stosowanego handlowego proszku tlenku glinu, rozkruszonej pianki cera- micznej. Wysoka kruchość cienkościennych, porowatych pianek Cu-Al2O3 pozwoliła na łatwe ich rozdrobnienie i wyodrębnienie frakcji o fragmentach wielkości < 200 /im. Dodatek fazy ceramicznej wynosił 3-10%obj. Proces spiekania prowadzono w temperaturze 1050°C w czasie 30 min i pod ciśnieniem 30 MPa. Celem pracy było określenie wpływu ilości dodatku fazy ceramicznej na mikrostrukturę oraz wybrane właściwości otrzymanych kompozytów.
Źródło:
Archives of Metallurgy and Materials; 2013, 58, 4; 1425-1428
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Researches and tests of high-speed circuit breakers for rolling stock and substations in 3 kV DC traction power system
Badania pojazdowych i podstacyjnych wyłączników szybkich w systemie zasilania trakcji 3 kV DC
Autorzy:
Rojek, A.
Sidorowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/952291.pdf
Data publikacji:
2013
Wydawca:
Instytut Kolejnictwa
Tematy:
wyłącznik szybki
zwarcia
prąd krytyczny
koordynacja zabezpieczeń
high-speed circuit breaker
short circuit
critical currents
coordination of protection
Opis:
Before placing in service in the railway electrical traction high-speed circuit-breakers shall be the subject of conformity tests with standards. The high-speed circuit breakers are an essential safeguard against the flow of an excessive current in the circuit overhead line and vehicles being powered by it. That is the reason why the circuit breakers must be equipped with systems which allow extinguish the high-energy arc. Additionally, the short circuit currents must be switched off as soon as possible to minimize the risk of damage, protected by circuit breakers, elements of an electric traction power supply system. The main document identifying requirements and a scope of the high-speed DC circuit breakers research for traction substation and sectioning cabins is the PN-EN 50123-2 standard. In the case of the on- board high-speed DC circuit breakers, requirements and scope of the research regulates the PN-EN 60077-3 standard. Although, two standards - PN-EN 50123 and PN-EN 60077-3 - apply to the same type of electric gear, the symbols and volume and parameter indexes used therein are different, what causes some inconvenience in analysis and results comparison, especially in terms of circuit breaker cooperation (f.e. in ensuring the coordination of short circuit protection in the traction vehicle - traction substation relation). Besides above standards, the requirements for high-speed DC circuit breakers are contained in PN-EN 50388 standard and technical specification for interoperability of the subsystem “Energy” (TSI “Energy”). For most of the test points and high speed D.C. circuit breaker checks, requirements that are contained in standards, testing and results are not problematic. However, part of the research and their result may be the basis of a discussion about real properties and parameters of circuit breakers. These tests and checks are contact life research, switching capacity check, designation and critical currents switching off and coordination of short circuit protection in the traction vehicle - traction substation relation. The data analysis presented by the producers of circuit breakers show that none of them classifies their products as one of the type: H, V or S, that are defined by PN-EN 50123 standard. Based on many measurements performed by Instytut Kolejnictwa it is possible to determine the type of high-speed D.C. circuit breakers designed to 3 kV D.C. system, produced by the leading European companies. The example of the current limiting very high-speed circuit breaker type V that is produced in Poland can be taken only one of a type DCN. The current limiting high-speed circuit breaker type H is a one of a series BWS, while circuit breakers UR40 is classified to the semi-high-speed circuit breaker type S. The next “imperfection” of the standards containing the requirements for high-speed D.C. circuit breakers is a guideline for short circuit. In such a short circuit should be only inductance and resistance. Whereas in the real conditions in short circuits, where high-speed circuit breakers are working, there are capacities, for example as filters in traction vehicles. Analyzing the short circuit current flow it can be stated that switching on of resonance filter caused extra switching off time about 10%. As a result of later release and oscillating changes of short circuit current, the value of maximum limiting short circuit current increases about 15%. The critical currents switching off are bonded with relatively long burning arc on the contacts of circuit breaker. The burning time of an arc while small values of currents switching off is form over a dozen to ten times longer, than short circuit currents. By this time, which can be up to few or even several seconds, the circuit breaker contacts are exposed to arc, arcing horns and arc chamber. It causes significant arcing erosion of these elements. The standards do not define at what time critical currents should be switched off and do not specify which critical currents value should be taken as a result of tests. To achieve selectivity of short circuit and overload currents switching offs forming in rolling stock is possible while on-board circuit breaker switches off the current before the circuit breaker for use in substations and sectioning cabins will get tripped. It will happen only when on-board circuit breaker limits the current to a value lower than the tripping level of the circuit breaker for use in the fixed installations. It will happen when steepness of short circuit grow is small enough that on-board circuit breaker starts to limit the current before it reaches the tripping level of high-speed circuit breaker for use in substation. The limit value di/dt, at which short circuit current will be switched off only be the on-board circuit breaker depends on independent opening time of on-board circuit breaker, its limiting current capacity and the difference between the value of setting of on-board circuit breaker for use in fixed installations. The results of the simulation, analysis and tests show, that it is not, at the moment, possible to obtain selective short circuit switching offs in rolling stock. At the European market of circuit breakers the greatest range of selectivity show vacuum circuit breakers DCN-L and DCU using in rolling stock.
Przed dopuszczeniem do eksploatacji w kolejowej trakcji elektrycznej wyłączniki szybkie prądu stałego muszą być poddane badaniom na zgodność z normami. Wyłączniki szybkie są podstawowym zabezpieczeniem przed przepływem nadmiernych wartości prądu w obwodach sieci trakcyjnej oraz zasilanych z niej pojazdów. Dlatego muszą być wyposażone w układy umożliwiające zgaszenie łuku o dużej energii. Dodatkowo prądy zwarciowe muszą być wyłączone w jak najkrótszym czasie, aby zminimalizować ryzyko uszkodzenia chronionych przez wyłączniki elementów systemu zasilania trakcji elektrycznej. Podstawowym dokumentem, określającym wymagania i zakres badań wyłączników szybkich prądu stałego przeznaczonych do podstacji trakcyjnych i kabin sekcyjnych, jest norma PN EN 50123-2. W przypadku wyłączników szybkich przeznaczonych do eksploatacji w pojazdach trakcyjnych wymagania i zakres badań reguluje norma PN-EN 60077-3. Pomimo, że obydwie normy dotyczą tego samego typu aparatów elektrycznych, stosowane w nich oznaczenia i indeksy wielkości i parametrów są inne, co powoduje pewne niedogodności w analizach i porównywaniu wyników, w szczególności w aspekcie współpracy wyłączników, np. przy zapewnianiu koordynacji zabezpieczeń zwarciowych w układzie pojazd trakcyjny – podstacja trakcyjna. Oprócz wymienionych norm, wymagania dla wyłączników szybkich są zawarte w normie PN-EN 50388 oraz specyfikacji technicznej interoperacyjności podsystemu „Energia”. Dla większości punktów zakresu badań i sprawdzeń wyłączników szybkich, wymagania zawarte w normach oraz przeprowadzenie i wyniki badań nie są problematyczne. Jednak część badań i ich wynik mogą być podstawą dyskusji dotyczących rzeczywistych właściwości i parametrów wyłączników. Do tych badań i sprawdzeń należą badanie trwałości łączeniowej, sprawdzenie zdolności łączeniowej prądów zwarciowych, wyznaczenie i wyłączenie prądów krytycznych i koordynacja zabezpieczeń zwarciowych w układzie pojazd trakcyjny – podstacja trakcyjna. Wyniki analizy danych przedstawianych przez producentów wyłączników pokazują, że żaden z nich nie klasyfikuje produkowanych wyłączników jako jednego z typów: H, V lub S, zdefiniowanych w normie PN-EN 50123. Na podstawie pomiarów prowadzonych przez Instytut Kolejnictwa jest możliwe określenie typu wyłączników szybkich prądu stałego przeznaczonych do systemu 3 kV DC, produkowanych przez czołowe firmy europejskie. Za wyłącznik typu V można uznać jedynie wyłącznik typu DCN. Wyłącznikiem typu H jest wyłącznik serii BWS, natomiast parametry wyłączników typu UR40. Kolejną „niedoskonałością” norm zawierających wymagania dla wyłączników szybkich prądu stałego, jest wytyczna dotycząca obwodu zwarciowego. W obwodzie tym powinny występować jedynie indukcyjność i rezystancja. Natomiast w warunkach rzeczywistych w obwodach zwarciowych, w których pracują wyłączniki szybkie występują pojemności, np. w postaci urządzeń wygładzających w podstacjach trakcyjnych lub filtrów wejściowych w pojazdach trakcyjnych. Analizując wyniki badań zwarciowych można stwierdzić, że załączenie urządzenia wygładzającego spowoduje wydłużenie czasu wyłączania o około 10%. W wyniku późniejszego wyzwolenia oraz oscylacyjnych zmian prądu zwarciowego, wartość maksymalnego ograniczonego prądu zwarcia zwiększa się o około 15%. Wyłączanie prądów krytycznych wiąże się ze stosunkowo długotrwałym paleniem łuku na stykach wyłącznika. Czas palenia się łuku przy wyłączaniu prądów o małej wartości jest od kilkunastu do kilkudziesięciu razy dłuższy, niż w przypadku wyłączania prądów zwarciowych. Przez ten czas, który może dochodzić do kilku, a nawet kilkunastu sekund, na działanie łuku są narażone styki wyłącznika, rożki łukowe i komora łukowa. Powoduje to znaczną erozję łukową tych elementów. Normy nie definiują w jakim czasie prądy krytyczne powinny być wyłączane oraz nie określają jaką wartość prądów krytycznych należy przyjmować jako wynik badań. Uzyskanie selektywności wyłączeń prądów zwarciowych i przetężeniowych powstających w taborze jest możliwe wówczas, gdy wyłącznik taborowy wyłączy prąd zanim zostanie wyzwolony wyłącznik w podstacji trakcyjnej lub w kabinie sekcyjnej. Nastąpi to tylko w przypadku, gdy wyłącznik taborowy ograniczy prąd do wartości niższej od poziomu wyzwolenia wyłącznika podstacyjnego. Wystąpi to w przypadku, gdy stromość wzrostu prądu zwarciowego będzie na tyle mała, że wyłącznik taborowy zacznie ograniczać prąd zanim osiągnie on poziom wyzwalania wyłącznika szybkiego w podstacji. Wartość graniczna di/dt, przy której prąd zwarciowy będzie wyłączany tylko przez wyłącznik taborowy, zależy od czasu własnego otwarcia wyłącznika w pojeździe, jego zdolności ograniczania prądu i różnicy pomiędzy wartościami nastaw wyłączników taborowego i podstacyjnego. Wyniki symulacji, analiz i badań pokazują, że obecnie nie jest możliwe uzyskanie każdorazowo selektywności wyłączeń prądów zwarciowych w taborze. Największy zakres selektywności można uzyskać w przypadku zastosowania w taborze próżniowych wyłączników serii DCN-L i DCU.
Źródło:
Problemy Kolejnictwa; 2013, 159; 7-30
0552-2145
2544-9451
Pojawia się w:
Problemy Kolejnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies