Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Sharma, T. N." wg kryterium: Autor


Tytuł:
Enhancement of Power Efficiency in OFDM System by SLM with Predistortion Technique
Autorzy:
Sharma, P. K.
Nagaria, R. K.
Sharma, T. N.
Powiązania:
https://bibliotekanauki.pl/articles/308396.pdf
Data publikacji:
2011
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
nonlinear HPA
OFDM
PAPR
SLM
Opis:
Orthogonal Frequency Division Multiplexing (OFDM) is considered as a strong candidate for future wireless communication because it is marked by its higher frequency multiplicity and greater immunity to multipath fading. However, the main drawback of OFDM is its high amplitude fluctuations measured by peak-to-average power ratio (PAPR), which leads to power inefficiency and requires expensive high power amplifier (HPA) with very good linearity. In this paper, we propose selected mapping (SLM) with predistortion technique to decrease the nonlinear distortion and to improve the power efficiency of the nonlinear HPA. In the proposed method SLM reduces the PAPR and improves the power efficiency, the predistorter improves the bit error rate (BER) performance of the system. The PAPR reduction is possible with SLM when compared with original OFDM. After reducing the PAPR with SLM the data goes into the HPA with and without predistorter. The BER performance curves of SLM method with or without predistorter shows that, predistorter operates more effectively in SLM method than original OFDM system. At 4 dB IBO (input backoff) the conventional method with predistorter achieves 1.8 dB SNR gain than conventional method without a predistorter and at 6 dB IBO the BER performance is towards the ideal linear amplifier. The proposed system will be evaluated for OFDM system in the presence of a nonlinear power amplifier.
Źródło:
Journal of Telecommunications and Information Technology; 2011, 4; 86-91
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Phytochemical and pharmacological aspects of Nothapodytes nimmoniana. An overview
Profil fitochemiczny i farmakologiczny Nothapodytes nimmoniana. Przegląd
Autorzy:
Khan, N.
Tamboli, E.T.
Sharma, V.K.
Kumar, S.
Powiązania:
https://bibliotekanauki.pl/articles/72676.pdf
Data publikacji:
2013
Wydawca:
Instytut Włókien Naturalnych i Roślin Zielarskich
Tematy:
phytochemistry
pharmacology
Nothapodytes nimmoniana
Icacinaceae
camptothecin
medicinal property
human disease
treatment
Opis:
Nothapodytes nimmoniana (J. Graham) (Icacinaceae), commonly known as Amruta is found in India particularly in Maharashtra, Goa, Kerala, Assam, Jammu and Kashmir as well as Tamilnadu areas. It is an important medicinal plant, the major source of a potent alkaloid, namely camptothecin, of a wide spectrum of pharmacological activities like anti-cancer, anti-HIV, antimalarial, antibacterial, anti-oxidant, anti-inflammatory, anti-fungal and also applied in the treatment of anaemia. Camptothecin is still not synthesized, therefore, its production entirely depends on natural sources. N. nimmoniana is one such plant which yields contain camptothecin in significantly high amount. The plant is gaining international recognition due to its diversified medicinal uses. It is subjected to excessive harvest. It has been categorized as a vulnerable and endangered plant. The present review encompasses the phytochemical, analytical, pharmacological, biotechnological, and other specific aspects of N. nimmoniana.
Nothapodytes nimmoniana (J. Graham) (Icacinaceae), powszechnie znana jako Amruta, rośnie w Indiach, szczególnie w prowincjach Maharashtra, Goa, Kerala, Assam, Dżammu i Kaszmir, a także na niektórych obszarach Tamilnadu. Jest jedną z ważnych roślin leczniczych, głównym źródłem silnego alkaloidu, kamptotecyny, mającej szerokie spektrum działania: przeciwnowotworowe, anty-HIV, antymalaryczne, antybakteryjne, przeciwutleniające, przeciwzapalne, przeciwgrzybicze. Znajduje również zastosowanie w leczeniu anemii. Jak dotąd kamptotecyna nie została zsyntetyzowana, dlatego jej produkcja całkowicie zależy od źródeł naturalnych. N. nimmoniana jest jedną z roślin zawierających duże ilości kamptotecyny. Zyskała ona międzynarodowe uznanie dzięki szerokiemu spektrum zastosowań, co powoduje zwiększenie jej eksploatacji. Z tego powodu została uznana za gatunek zagrożony. Poniższy przegląd obejmuje badania fitochemiczne, analityczne, farmakologiczne, biotechnologiczne i inne prowadzone nad gatunkiem N. nimmoniana.
Źródło:
Herba Polonica; 2013, 59, 1
0018-0599
Pojawia się w:
Herba Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Leaching of Al-Based Polygrain Quasicrystalline and Related Crystalline Surfaces
Autorzy:
Yadav, T.
Mishra, S.
Pandey, S.
Singh, D.
Lowe, M.
Tamura, R.
Mukhopadhyay, N.
Srivastava, O.
McGrath, R.
Sharma, H.
Powiązania:
https://bibliotekanauki.pl/articles/1373698.pdf
Data publikacji:
2014-08
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
61.44.Br
81.16.Hc
61.66.Dk
68.37.Hk
Opis:
In the present investigation, we have studied leaching on polygrain Al-based quasicrystalline $(i-Al_{63}Cu_{25}Fe_{12})$ as well as crystalline (B2 phase; $Al_{55}Cu_{30}Fe_{15})$ alloy surfaces using a 10 mole NaOH solution. The surface was leached at varying times from 30 min to 8 h and subsequently characterized by X-ray diffraction, scanning electron microscopy, transmission electron microscopy and energy dispersive X-ray analysis. Leaching of the samples for 30 min generated a homogeneous layer. However further leaching for 1-8 h yielded nano-size particles on the surface. Spherical microstructure has been observed on the Al-Cu-Fe crystalline surface whereas on the quasicrystalline surface a petal-like microstructure appeared. The implications of the evolution of different microstructures in the context of structure, stability and activity are discussed. The results are compared with the microstructure of leached polygrained samples containing a mixture of different surface orientations.
Źródło:
Acta Physica Polonica A; 2014, 126, 2; 629-632
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of the compress sensing theory for improvement of the TOF resolution in a novel J-PET instrument
Autorzy:
Raczyński, L.
Moskal, P.
Kowalski, P.
Wiślicki, W.
Bednarski, T.
Białas, P.
Czerwiński, E.
Gajos, A.
Kapłon, Ł.
Kochanowski, A.
Korcyl, G.
Kowal, J.
Kozik, T.
Krzemień, W.
Kubicz, E.
Niedźwiecki, S.
Pałka, M.
Rudy, Z.
Salabura, P.
Gupta-Sharma, N.
Silarski, M.
Słomski, A.
Smyrski, J.
Strzelecki, A.
Wieczorek, A.
Zieliński, M.
Zoń, N.
Powiązania:
https://bibliotekanauki.pl/articles/146280.pdf
Data publikacji:
2016
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
compressed sensing
positron emission tomography
time-of-flight
Opis:
Nowadays, in positron emission tomography (PET) systems, a time of fl ight (TOF) information is used to improve the image reconstruction process. In TOF-PET, fast detectors are able to measure the difference in the arrival time of the two gamma rays, with the precision enabling to shorten signifi cantly a range along the line-of-response (LOR) where the annihilation occurred. In the new concept, called J-PET scanner, gamma rays are detected in plastic scintillators. In a single strip of J-PET system, time values are obtained by probing signals in the amplitude domain. Owing to compressive sensing (CS) theory, information about the shape and amplitude of the signals is recovered. In this paper, we demonstrate that based on the acquired signals parameters, a better signal normalization may be provided in order to improve the TOF resolution. The procedure was tested using large sample of data registered by a dedicated detection setup enabling sampling of signals with 50-ps intervals. Experimental setup provided irradiation of a chosen position in the plastic scintillator strip with annihilation gamma quanta.
Źródło:
Nukleonika; 2016, 61, 1; 35-39
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Pilot Study of the Novel J-PET Plastic Scintillator with 2-(4-styrylphenyl)benzoxazole as a Wavelength Shifter
Autorzy:
Wieczorek, A.
Moskal, P.
Niedźwiecki, S.
Bednarski, T.
Białas, P.
Czerwiński, E.
Danel, A.
Gajos, A.
Gruntowski, A.
Kamińska, D.
Kapłon, Ł.
Kochanowski, A.
Korcyl, G.
Kowal, J.
Kowalski, P.
Kozik, T.
Krzemień, W.
Kubicz, E.
Molenda, M.
Pałka, M.
Raczyński, L.
Rudy, Z.
Rundel, O.
Salabura, P.
Sharma, N.
Silarski, M.
Słomski, A.
Smyrski, J.
Strzelecki, A.
Uchacz, T.
Wiślicki, W.
Zieliński, M.
Zoń, N.
Powiązania:
https://bibliotekanauki.pl/articles/1402620.pdf
Data publikacji:
2015-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
87.57.uk
29.40.Mc
Opis:
For the first time a molecule of 2-(4-styrylphenyl)benzoxazole containing benzoxazole and stilbene groups is applied as a scintillator dopant acting as a wavelength shifter. In this article a light yield of the plastic scintillator, prepared from styrene doped with 2 wt% of 2,5-diphenylbenzoxazole and 0.03 wt% of 2-(4-styrylphenyl)benzoxazole, is determined to be as large as 60% ± 2% of the anthracene light output. There is a potential to improve this value in the future by the optimization of the additives concentrations.
Źródło:
Acta Physica Polonica A; 2015, 127, 5; 1487-1490
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
GPU Accelerated Image Reconstruction in a Two-Strip J-PET Tomograph
Autorzy:
Białas, P.
Kowal, J.
Strzelecki, A.
Bednarski, T.
Czerwiński, E.
Gajos, A.
Kamińska, D.
Kapłon, Ł.
Kochanowski, A.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krzemień, W.
Kubicz, E.
Moskal, P.
Niedźwiecki, Sz.
Pałka, M.
Raczyński, L.
Rudy, Z.
Rundel, O.
Salabura, P.
Sharma, N.
Silarski, M.
Słomski, A.
Smyrski, J.
Wieczorek, A.
Wiślicki, W.
Zieliński, M.
Zoń, N.
Powiązania:
https://bibliotekanauki.pl/articles/1402623.pdf
Data publikacji:
2015-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
87.57.nf
87.57.uk
Opis:
We present a fast GPU implementation of the image reconstruction routine, for a novel two strip PET detector that relies solely on the time of flight measurements.
Źródło:
Acta Physica Polonica A; 2015, 127, 5; 1500-1504
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Method to Produce Linearly Polarized Positrons and Positronium Atoms with the J-PET Detector
Autorzy:
Mohammed, Muhsin
Białas, P.
Curceanu, C.
Czerwiński, E.
Dulski, K.
Gajos, A.
Głowacz, B.
Gorgol, M.
Hiesmayr, B.
Jasińska, B.
Kisielewska, D.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krawczyk, N.
Krzemień, W.
Kubicz, E.
Pawlik-Niedźwiecka, M.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Raj, J.
Rudy, Z.
Sharma, N.
Sharma, S.
Shivani, ---
Skurzok, M.
Silarski, M.
Wieczorek, A.
Wiślicki, W.
Zgardzińska, B.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/1030045.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
41.75.Fr
41.75.Ht
77.22.Ej
36.10.Dr
85.75.Mm
87.57.uk
Opis:
A method for creating linearly polarized positrons and ortho-positronium (o-Ps) atoms with the J-PET detector is presented. The unique geometry and properties of the J-PET tomography enable one to design a positron source such that the quantization axis for the estimation of the linear polarization of produced o-Ps can be determined on the event by event basis in a direction of the positron motion. We intend to use ²²Na or other β⁺ decay isotopes as a source of polarized positrons. Due to the parity violation in the beta decay, the emitted positrons are longitudinally polarized. The choice of the quantization axis is based on the known position of the positron emitter and the reconstructed position of the positronium annihilation. We show that the J-PET tomography is equipped with all needed components.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1486-1489
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hit Time and Hit Position Reconstruction in the J-PET Detector Based on a Library of Averaged Model Signals
Autorzy:
Moskal, P.
Sharma, N.
Silarski, M.
Bednarski, T.
Białas, P.
Bułka, J.
Czerwiński, E.
Gajos, A.
Kamińska, D.
Kapłon, L.
Kochanowski, A.
Korcyl, G.
Kowal, J.
Kowalski, P.
Kozik, T.
Krzemień, W.
Kubicz, E.
Niedźwiecki, Sz.
Pałka, M.
Raczyński, L.
Rudy, Z.
Rundel, O.
Salabura, P.
Słomski, A.
Smyrski, J.
Strzelecki, A.
Wieczorek, A.
Wiślicki, W.
Wochlik, I.
Zieliński, M.
Zoń, N.
Powiązania:
https://bibliotekanauki.pl/articles/1402622.pdf
Data publikacji:
2015-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
87.57.uk
07.05.Kf
Opis:
In this article we present a novel method of hit time and hit position reconstruction in long scintillator detectors. We take advantage of the fact that for this kind of detectors amplitude and shape of registered signals depend strongly on the position where particle hits the detector. The reconstruction is based on determination of the degree of similarity between measured and averaged signals stored in a library for a set of well-defined positions along the scintillator. Preliminary results of validation of the introduced method with experimental data obtained by means of the double strip prototype of the J-PET detector are presented.
Źródło:
Acta Physica Polonica A; 2015, 127, 5; 1495-1499
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multiple Scattering and Accidental Coincidences in the J-PET Detector Simulated Using GATE Package
Autorzy:
Kowalski, P.
Moskal, P.
Wiślicki, W.
Raczyński, L.
Bednarski, T.
Białas, P.
Bułka, J.
Czerwiński, E.
Gajos, A.
Gruntowski, A.
Kamińska, D.
Kapłon, Ł.
Kochanowski, A.
Korcyl, G.
Kowal, J.
Kozik, T.
Krzemień, W.
Kubicz, E.
Niedźwiecki, Sz.
Pałka, M.
Rudy, Z.
Salabura, P.
Sharma, N.
Silarski, M.
Słomski, A.
Smyrski, J.
Strzelecki, A.
Wieczorek, A.
Wochlik, I.
Zieliński, M.
Zoń, N.
Powiązania:
https://bibliotekanauki.pl/articles/1402625.pdf
Data publikacji:
2015-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
29.40.Mc
87.57.uk
87.10.Rt
34.50.-s
Opis:
Novel positron emission tomography system, based on plastic scintillators, is developed by the J-PET collaboration. In order to optimize geometrical configuration of built device, advanced computer simulations are performed. Detailed study is presented of background given by accidental coincidences and multiple scattering of gamma quanta.
Źródło:
Acta Physica Polonica A; 2015, 127, 5; 1505-1512
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis Procedure of the Positronium Lifetime Spectra for the J-PET Detector
Autorzy:
Dulski, K.
Zgardzińska, B.
Białas, P.
Curceanu, C.
Czerwiński, E.
Gajos, A.
Głowacz, B.
Gorgol, M.
Hiesmayr, B.
Jasińska, B.
Kisielewska-Kamińska, D.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krawczyk, N.
Krzemień, W.
Kubicz, E.
Mohammed, Muhsin
Pawlik-Niedźwiecka, M.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Raj, J.
Rudy, Z.
Sharma, N.
Sharma, S.
Shivani, Shivani
Shopa, R.
Silarski, M.
Skurzok, M.
Wieczorek, A.
Wiślicki, W.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/1033298.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
07.05.Kf
13.30.Ce
14.60.-z
78.47.-p
Opis:
Positron annihilation lifetime spectroscopy has shown to be a powerful tool to study the nanostructures of porous materials. Positron emission tomograph is a device allowing imaging of metabolic processes e.g. in human bodies. A newly developed device, the Jagiellonian PET will allow positron annihilation lifetime spectroscopy in addition to imaging, thus combining both analyses providing new methods for physics and medicine. In this contribution we present a computer program that is compatible with the Jagiellonian PET software. We compare its performance with the standard program LT 9.0 by using positron annihilation lifetime spectroscopy data from hexane measurements at different temperatures. Our program is based on an iterative procedure, and our fits prove that it performs as good as LT 9.0.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1637-1640
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Time Calibration of the J-PET Detector
Autorzy:
Skurzok, M.
Silarski, M.
Alfs, D.
Białas, P.
Shivani, S.
Curceanu, C.
Czerwiński, E.
Dulski, K.
Gajos, A.
Głowacz, B.
Gorgol, M.
Hiesmayr, B.
Jasińska, B.
Kisielewska-Kamińska, D.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krawczyk, N.
Krzemień, W.
Kubicz, E.
Mohammed, Muhsin
Pawlik-Niedźwiecka, M.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Raj, J.
Rudy, Z.
Sharma, N.
Sharma, S.
Shopa, R.
Wieczorek, A.
Wiślicki, W.
Zgardzińska, B.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/1033283.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
06.20.fb
36.10.Dr
11.30.Er
24.80.+y
Opis:
The Jagiellonian positron emission tomograph project carried out in the Institute of Physics of the Jagiellonian University is focused on construction and tests of the first prototype of PET scanner for medical diagnostic which allows for the simultaneous 3D imaging of the whole human body using organic scintillators. The J-PET prototype consists of 192 scintillator strips forming three cylindrical layers which are optimized for the detection of photons from the electron-positron annihilation with high time-and high angular resolutions. In this article we present time calibration and synchronization of the whole J-PET detection system by irradiating each single detection module with a ²²Na source and a small detector providing common reference time for synchronization of all the modules.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1641-1644
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis Framework for the J-PET Scanner
Autorzy:
Krzemień, W.
Gajos, A.
Gruntowski, A.
Stola, K.
Trybek, D.
Bednarski, T.
Białas, P.
Czerwiński, E.
Kamińska, D.
Kapłon, Ł.
Kochanowski, A.
Korcyl, G.
Kowal, J.
Kowalski, P.
Kozik, T.
Kubicz, E.
Moskal, P.
Niedźwiecki, Sz.
Pałka, M.
Raczyński, L.
Rudy, Z.
Salabura, P.
Sharma, N.
Silarski, M.
Słomski, A.
Smyrski, J.
Strzelecki, A.
Wieczorek, A.
Wiślicki, W.
Zieliński, M.
Zoń, N.
Powiązania:
https://bibliotekanauki.pl/articles/1402621.pdf
Data publikacji:
2015-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
87.57.nf
87.57.uk
29.85.-c
Opis:
J-PET analysis framework is a flexible, lightweight, ROOT-based software package which provides the tools to develop reconstruction and calibration procedures for PET tomography. In this article we present the implementation of the full data-processing chain in the J-PET framework which is used for the data analysis of the J-PET tomography scanner. The framework incorporates automated handling of PET setup parameters' database as well as high level tools for building data reconstruction procedures. Each of these components is briefly discussed.
Źródło:
Acta Physica Polonica A; 2015, 127, 5; 1491-1494
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary studies of J-PET detector spatial resolution
Autorzy:
Pawlik-Niedźwiecka, M.
Niedźwiecki, S.
Alfs, D.
Białas, P.
Curceanu, C.
Czerwiński, E.
Dulski, K.
Gajos, A.
Głowacz, B.
Gorgol, M.
Hiesmayr, B.
Jasińska, B.
Kisielewska, D.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krawczyk, N.
Krzemień, W.
Kubicz, E.
Mohammed, M.
Pałka, M.
Raczyński, L.
Raj, J.
Rudy, Z.
Shivani, -
Silarski, M.
Skurzok, M.
Sharma, N.
Sharma, S.
Shopa, R.
Strzelecki, A.
Wieczorek, A.
Wiślicki, W.
Zgardzińska, B.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/1057928.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
29.40.Mc
87.57.uk
87.10.Rt
34.50.-s
Opis:
The J-PET detector, based on long plastic scintillator strips, was recently constructed at the Jagiellonian University. It consists of 192 modules axially arranged into three layers, read out from both sides by digital constant-threshold front-end electronics. This work presents preliminary results of measurements of the spatial resolution of the J-PET tomograph performed with ²²Na source placed at selected position inside the detector chamber.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1645-1648
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Human tissue investigations using PALS technique - free radicals influence
Autorzy:
Jasińska, B.
Zgardzińska, B.
Chołubek, G.
Pietrow, M.
Gorgol, M.
Wiktor, K.
Wysogląd, K.
Białas, P.
Curceanu, C.
Czerwiński, E.
Dulski, K.
Gajos, A.
Głowacz, B.
Hiesmayr, B.
Jodłowska-Jędrych, B.
Kamińska, D.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krawczyk, N.
Krzemień, W.
Kubicz, E.
Mohammed, Muhsin
Pawlik-Niedźwiecka, M.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Rudy, Z.
Sharma, N.
Sharma, S.
Shopa, R.
Silarski, M.
Skurzok, M.
Wieczorek, A.
Wiktor, H.
Wiślicki, W.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/1057941.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
positron annihilation
positronium
free radicals
tissues
uterine leiomyomas
Opis:
The positron annihilation lifetime spectroscopy was applied to the samples of the human uterine leiomyomas and the normal myometrium tissues taken from the selected place of the uterus during a surgery. The method indicated differences in values of the measured positron annihilation lifetime spectroscopy parameters (lifetimes and intensities) between healthy and diseased tissue samples. The additional measurements were performed either in darkness or in presence of visible light which influenced the free radicals present in both kind of tissues and, as a result, made changes in free annihilation and o-Ps decay lifetime and intensity values.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1556-1558
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reconstruction of hit time and hit position of annihilation quanta in the J-PET detector using the Mahalanobis distance
Autorzy:
Sharma, N. G.
Silarski, M.
Bednarski, T.
Białas, P.
Czerwiński, E.
Gajos, A.
Gorgol, M.
Jasińska, B.
Kamińska, D.
Kapłon, Ł.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krzemień, W.
Kubicz, E.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Rudy, Z.
Rundel, O.
Słomski, A.
Strzelecki, A.
Wieczorek, A.
Wiślicki, W.
Zieliński, M.
Zgardzińska, B.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/146937.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
J-PET detector
Mahalanobis distance
time resolution
threshold levels
Opis:
The J-PET detector being developed at the Jagiellonian University is a positron emission tomograph composed of the long strips of polymer scintillators. At the same time, it is a detector system that will be used for studies of the decays of positronium atoms. The shape of photomultiplier signals depends on the hit time and hit position of the gamma quantum. In order to take advantage of this fact, a dedicated sampling front-end electronics that enables to sample signals in voltage domain with the time precision of about 20 ps and novel reconstruction method based on the comparison of examined signal with the model signals stored in the library has been developed. As a measure of the similarity, we use the Mahalanobis distance. The achievable position and time resolution depend on the number and values of the threshold levels at which the signal is sampled. A reconstruction method as well as preliminary results are presented and discussed.
Źródło:
Nukleonika; 2015, 60, No. 4, part 1; 765-769
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies