Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Ratajczyk, T." wg kryterium: Autor


Wyświetlanie 1-5 z 5
Tytuł:
Web analytics combined with eye tracking for successful user experience design: a case study
Autorzy:
Borys, M.
Czwórnóg, M.
Ratajczyk, T.
Powiązania:
https://bibliotekanauki.pl/articles/118111.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Promocji Wiedzy
Tematy:
user experience design
mobile website design
eye-tracking
case study
Opis:
The authors propose a new approach for the mobile user experience design process by means of web analytics and eye-tracking. The proposed method was applied to design the LUT mobile website. In the method, to create the mobile website design, data of various users and their behaviour were gather-ed and analysed using the web analytics tool. Next, based on the findings from web analytics, the mobile prototype for the website was created and validated in eye-tracking usability testing. The analysis of participants’ behaviour during eye-tracking sessions allowed improvements of the prototype.
Źródło:
Applied Computer Science; 2016, 12, 4; 96-110
1895-3735
Pojawia się w:
Applied Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dokładność tomografów przemysłowych CT w wyznaczaniu wymiarów geometrycznych
The accuracy of industrial computer tomography scanners in determining geometric dimensions
Autorzy:
Kowaluk, T.
Ratajczyk, E.
Powiązania:
https://bibliotekanauki.pl/articles/152447.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
tomografia komputerowa CT
wzorce geometryczne
dokładność pomiarów
model CAD
computer tomography
geometric gauges
accuracy of measurements
CAD model
Opis:
Zaprezentowano metodę w zakresie wyznaczania dokładności wymiarów geometrycznych przemysłowych tomografów komputerowych zgodnie z wytycznymi VDI/VDE 2630. Zaprezentowano propozycje sprawdzenia dokładności tomografu opartą na wzorcu składającym się z zestawu trzpieni z końcówkami kulistymi. Opisano wzorzec zaprojektowany i skonstruowany w Instytucie Metrologii i Inżynierii Biomedycznej Politechniki Warszawskiej. Wzorzec został wykalibrowany za pomocą współrzędnościowej maszyny pomiarowej ACCURA firmy C. Zeiss. Na podstawie uzyskanych danych pomiarowych wykonany został model CAD wzorca. Uzyskane podczas pomiarów tomograficznych chmury punktów zostały porównane z modelem CAD. Przeprowadzono analizę statystyczną uzyskanych wyników oraz sprawdzono podawaną przez producenta dokładność pomiarów geometrycznych tomografu komputerowego METROTOM 800.
This paper presents the construction of a computer tomography scanner (CT). It discusses the principles of operation of CT. The parameters characterizing the accuracy are described. The proposed method for determining the geometric dimension accuracy of industrial computer tomography scanners according to VDI / VDE 2630 is discussed. The presented proposals can be used to verify the tomography scanner accuracy based on gauges consisting of a set of spherical stylus. A gauge to check the CT accuracy was designed and constructed at the Institute of Metrology and Biomedical Engineering, the Warsaw University of Technology. The gauge was calibrated using a coordinate measuring machine ACCURA 7 by C. Zeiss. Based on the measurement data a CAD model of the gauge was made. The measurement strategies were based on the CAD model. The point clouds for tomographic measurements were compared with the CAD model. The results of the two measuring devices were compared. Statistical analysis of the results was conducted. It showed statistically significant differences between the methods of measuring on the confidence level of 95%. It was also confirmed by the statistical parameters obtained for the both methods. The values of the range and standard deviations were approximately twice as high for the tomographic measurements. Also the accuracy specified by the manufacturer of CT METROTOM 800 was verified.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 5, 5; 462-465
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania porównawcze pomiarów wykonywanych za pomocą współrzędnościowego ramienia pomiarowego wyposażonego w głowicę sztywną i impulsową
Comparative studies of measurements made by a coordinate measuring arm equipped with hard and trigger probes
Autorzy:
Rak, M.
Ratajczyk, E.
Kowaluk, T.
Powiązania:
https://bibliotekanauki.pl/articles/153541.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
współrzędnościowe ramię pomiarowe
głowica (sonda) pomiarowa
coordinate measuring arm (portable CMM)
measuring probe
Opis:
Przedstawiona jest ocena dokładności pomiarów przeprowadzonych głowicą sztywną i przełączającą za pomocą współrzędnościowego ramienia pomiarowego [1]. Ramiona współrzędnościowe są mobilnymi ręcznymi przyrządami pomiarowymi. W celu lokalizacji punktów pomiarowych wyposażone są najczęściej w głowice sztywne. Dzięki użyciu w jednym ramieniu zarówno głowicy sztywnej jak i przełączającej możliwe było porównanie ich ze sobą. Badania eksperymentalne wykonano na podstawie wybranych wymiarów elementu w postaci kostki szkoleniowej. Otrzymane wyniki badań pozwalają ocenić stopień dokładności przy stosowaniu poszczególnych rodzajów głowic.
The purpose of the paper is to assess the accuracy of measurements made with hard and trigger probes on a coordinate measuring arm. In the case of hard heads the measuring force is variable and depends on an operator who decides on appearance of a contact of the stylus tip with the measured surface, while in the case of trigger probes the contact of the tip with the measured surface is independent of shaft swings, breaking the electrical contact inside the head due to deflection of the stylus and breaking the electrical contact inside the head. The study was conducted with use of the arm Metris – Nikon MCA II shown in Fig. 1. Arms are manual measuring devices equipped, in most cases, with hard probes. Through the use of hard and trigger probes in one arm, it is possible to compare two heads. The TP20 kinematic touch-trigger probe with an SF module (standard force) was used as a trigger head. The paper presents a brief description of coordinate measurements as well as construction and working principle of coordinate measuring arms. In Fig. 3 there is shown a CAD model of the training cube used as a test part. The tests were made on the basis of measurements of four cylindrical holes with different diameters. The obtained results for two probes were compared with each other. It was analyzed how the range of results for different diameters for hard and trigger probes changed. The results show the influence of other factors (besides the measuring force). To show the influence of the measuring force, tests on a cube made of different materials were also performed.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 5, 5; 456-458
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie powtarzalności pomiarów geometrycznych na tomografie komputerowym CT
The study of repeatability of geometric measurements on a computer tomography scanner
Autorzy:
Kowaluk, T.
Ratajczyk, E.
Rak, M.
Powiązania:
https://bibliotekanauki.pl/articles/151143.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
tomografia komputerowa
powtarzalność pomiarów
drukarki 3D
model CAD
computer tomography
repeatability of measurements
3D printer
Opis:
Przedstawiono wyniki badań powtarzalności pomiarów geometrycznych na przykładzie tzw. "kostki szkoleniowej" poprzedzając krótką charakterystyką przemysłowego tomografu komputerowego MTROTOM 800 oraz oprogramowań. Programu METROTOM OS w którym ustawiane są parametry pomiarowe i wykonywane są pomiary oraz programu CALYPSO służącego do analizy uzyskanych z pomiaru chmur punktów. Przedstawiono wyniki pomiarów odległości płaszczyzn, średnic otworów oraz odległości między nimi. Strategia pomiarowa została oparta na modelu CAD a uzyskane wyniki z pomiarów tomograficznych w postaci chmury punktów zostały porównane z wymiarami zawartymi w modelu CAD. Porównanie odnosi się do wymiarów nominalnych jak i do pola tolerancji w funkcji odchyłek. Wyniki te pozwoliły również na ocenę dokładności "druku" w jakim to procesie wykonana została badana kostka. Kostka została wydrukowana z dostępnego modelu CAD. W badaniach porównano powtarzalność pomiarów elementów geometrycznych jak i odchyłki od wartości nominalnej kostki. W celu obliczenia parametrów statystycznych dokonano dziesięciokrotnego pomiaru kostki.
The results of tests of repeatability of geometric measurements on an example of the so-called "training cube" are presented in the paper. The short characteristics of the industrial computed tomography scanner METROTOM 800 is given. The software METROTOM OS, in which measurement parameters are set, and CALYPSO for analysis of the point clouds obtained from measurements are discussed. The results of measurements of surface distance, hole diameters and distances between them are presented. The measurement strategy was based on the CAD model and the results of tomographic measurements in the form of point clouds were compared with the dimensions contained in the CAD model. The comparison referred to the nominal dimensions and the tolerance field as a function of deviations. These results allowed the evaluation of the accuracy of "printing" process in which the tested "training cube" was performed. The cube was printed from the available CAD model. The study compared the repeatability of the measurement of geometric elements and deviations from the nominal value of the cube. In order to calculate statistical parameters, the cube was measured ten times. The summary of the standard deviations and the ranges shows high repeatability of tomographic measurements. The value of standard deviations equaled 1 to 2.7 microns and the values of ranges were 3.3 to 8 microns.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 5, 5; 459-461
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of method of points collection on results with the use of measuring arm
Autorzy:
Ratajczyk, E.
Rak, M.
Kowaluk, T.
Powiązania:
https://bibliotekanauki.pl/articles/221884.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
scanning
pseudo-scanning
measuring arm
Opis:
Comparison studies of different measurement methods using a Coordinate Measuring Arm are presented. Studies were divided into two parts. The first was point measurements of contact and pseudo-scanning contact measurements. The second part consisted of point measurements of contact and non-contact scanning measurements. Contact research (point measurements and the pseudo-scanning) were accomplished with the use of PowerINSPECT software, whereas non-contact with use of Focus Handheld and Focus Inspection software. Handheld Focus was used to collect a point cloud and its processing, while the detection of set elements was made using the second software from the group of Focus. According to the developed procedure for both parts sample elements with known nominal values were measured (available CAD model of object of research). It became the basis for examining whether there are statistically significant differences between results of different methods in both parts. Statistical comparison of measurement methods was carried out using four tests: Comparison of Means, Comparison of Standard Deviations, Comparison of Medians and a Kolmogorov-Smirnov Test.
Źródło:
Metrology and Measurement Systems; 2012, 19, 3; 541-552
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies