Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Palka, G." wg kryterium: Autor


Tytuł:
The Effect of Cooling Rate after Homogenization on the Microstructure and Properties of 2017a Alloy Billets for Extrusion with Solution Heat Treatment on the Press
Autorzy:
Woźnicki, A.
Leśniak, D.
Włoch, G.
Pałka, P.
Leszczyńska-Madej, B.
Wojtyna, A.
Powiązania:
https://bibliotekanauki.pl/articles/355500.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
2017A alloy
cooling rate after homogenization
θ (Al2Cu) phase particles precipitation
Opis:
The influence of cooling rate after homogenization on the 2017A alloy microstructure was analysed. The capability of the θ (Al2Cu) particles, precipitated during various homogenization coolings, for rapid dissolution was estimated. For this purpose, the DSC test was used to determine the effect of the cooling rate after homogenization on the course of melting during a rapid heating. Moreover, the samples after solution heat treatment (with short time annealing) and ageing, were subjected to the microstructure investigations and the microhardness of grains interiors measurements. It was found that cooling after homogenization at 160 °C/h is sufficient for precipitation of fine θ phase particles, which dissolve during the subsequent rapid heating. The cooling at 40 °C/h, causes the precipitation of θ phase in the form of large particles, incapable of further fast dissolution.
Źródło:
Archives of Metallurgy and Materials; 2016, 61, 3; 1663-1670
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Pilot Study of the Novel J-PET Plastic Scintillator with 2-(4-styrylphenyl)benzoxazole as a Wavelength Shifter
Autorzy:
Wieczorek, A.
Moskal, P.
Niedźwiecki, S.
Bednarski, T.
Białas, P.
Czerwiński, E.
Danel, A.
Gajos, A.
Gruntowski, A.
Kamińska, D.
Kapłon, Ł.
Kochanowski, A.
Korcyl, G.
Kowal, J.
Kowalski, P.
Kozik, T.
Krzemień, W.
Kubicz, E.
Molenda, M.
Pałka, M.
Raczyński, L.
Rudy, Z.
Rundel, O.
Salabura, P.
Sharma, N.
Silarski, M.
Słomski, A.
Smyrski, J.
Strzelecki, A.
Uchacz, T.
Wiślicki, W.
Zieliński, M.
Zoń, N.
Powiązania:
https://bibliotekanauki.pl/articles/1402620.pdf
Data publikacji:
2015-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
87.57.uk
29.40.Mc
Opis:
For the first time a molecule of 2-(4-styrylphenyl)benzoxazole containing benzoxazole and stilbene groups is applied as a scintillator dopant acting as a wavelength shifter. In this article a light yield of the plastic scintillator, prepared from styrene doped with 2 wt% of 2,5-diphenylbenzoxazole and 0.03 wt% of 2-(4-styrylphenyl)benzoxazole, is determined to be as large as 60% ± 2% of the anthracene light output. There is a potential to improve this value in the future by the optimization of the additives concentrations.
Źródło:
Acta Physica Polonica A; 2015, 127, 5; 1487-1490
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
PALS investigations of free volumes thermal expansion of J-PET plastic scintillator synthesized in polystyrene matrix
Autorzy:
Wieczorek, A.
Zgardzińska, B.
Jasińska, B.
Gorgol, M.
Bednarski, T.
Białas, P.
Czerwiński, E.
Gajos, A.
Kamińska, D.
Kapłon, Ł.
Kochanowski, A.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krzemień, W.
Kubicz, E.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Rudy, Z.
Rundel, O.
Sharma, N. G.
Silarski, M.
Silarski, A.
Strzelecki, A.
Wiślicki, W.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/147132.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
free volume
positron annihilation
polystyrene
positronium
scintillator
Opis:
The polystyrene doped with 2,5-diphenyloxazole as a primary fluor and 2-(4-styrylphenyl)benzoxazole as a wavelength shifter prepared as a plastic scintillator was investigated using positronium probe in wide range of temperatures from 123 to 423 K. Three structural transitions at 260, 283, and 370 K were found in the material. In the o-Ps intensity dependence on temperature, the significant hysteresis is observed. Heated to 370 K, the material exhibits the o-Ps intensity variations in time.
Źródło:
Nukleonika; 2015, 60, No. 4, part 1; 777-781
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mechanical Properties of Composites with Titanium Diboride Fabricated by Spark Plasma Sintering
Autorzy:
Sulima, I.
Boczkal, G.
Palka, P.
Powiązania:
https://bibliotekanauki.pl/articles/352589.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
composite
spark plasma sintering (SPS)
mechanical properties
Opis:
Microstructure and mechanical properties of the 316L steel composite reinforced with TiB2 phase were examined. The test materials were obtained by SPS technique from powders. From testing of the mechanical properties it follows that the optimum temperature for the fabrication of 316Lsteel-TiB2 composites by SPS is 1100°C. Studies have also proved that the critical content of TiB2 phase in steel matrix should not exceed 6vol%. Above this level, the plastic properties of the composite become unstable and strongly dependent on the time of sintering.
Źródło:
Archives of Metallurgy and Materials; 2017, 62, 3; 1665-1671
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania i ocena skuteczności oczyszczania ścieków pestycydowych metodą koagulacyjno-adsorpcyjną
Studies evaluating the effectiveness of pesticide sewage purification with the use of coagulation-adsorption method
Autorzy:
Stężała, S.
Wieczorek, S.
Świst, E.
Pałka, G.
Powiązania:
https://bibliotekanauki.pl/articles/239434.pdf
Data publikacji:
2011
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
pestycydy
ścieki eksploatacyjne
koagulacja
stopień oczyszczenia ścieków
pesticides
exploitation sewage
coagulation method
treatment
sewage purification degree
Opis:
W pracy przedstawiono przebieg i wyniki badań oczyszczania rolniczych ścieków pestycydowych metodą koagulacyjno-adsorpcyjną. Opracowano i dobrano odpowiednie koagulanty oraz parametry ich stosowania podczas oczyszczania ścieków. Na ich podstawie opracowano metodę koagulacyjnego oczyszczania ścieków. Wyznaczono zależności pomiędzy krotnością rozcieńczenia zanieczyszczeń, w postaci pozostałości roboczych roztworów pestycydowych, a ich ChZT i zawartością substancji czynnej oraz zależności zawartości substancji czynnej od wartości ChZT dla badanych roztworów przed i po koagulacji. Zaproponowano kryterium oceny stopnia oczyszczenia, umożliwiającego odprowadzanie oczyszczonych ścieków do naturalnych, otwartych, przepływowych ujęć wodnych, z możliwością wykorzystania wskaźnika ChZT.
Paper presented the course and results of studies on the treatment of agricultural pesticide sewage with the use of coagulation-adsorption method. Suitable coagulants, as well as their parameters during sewage treatment, were devised and selected. On such a basis coagulation method of sewage purification was elaborated. Relationships were determined between degree of contamination dilution in form of active pesticide residues in solutions and their COD, as well as the dependence of active substance content on COD value for the solutions tested, before and after coagulation. A criterion based on the possibility of using COD value was proposed to evaluate the purification degree of treated sewages, enabling their release into open, natural water intakes.
Źródło:
Problemy Inżynierii Rolniczej; 2011, R. 19, nr 4, 4; 117-127
1231-0093
Pojawia się w:
Problemy Inżynierii Rolniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wybór i zastosowanie lanych elastomerów uretanowych w dźwigniowo-sprężynowych bezpiecznikach pługów
Choice and application of cast urethane elastomers to lever-spring overload lockings in the ploughs
Autorzy:
Stężała, S.
Ptaszyński, S.
Pałka, G.
Wieczorek, S.
Powiązania:
https://bibliotekanauki.pl/articles/239644.pdf
Data publikacji:
2005
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
bezpiecznik
pług
sprężyna
elastomer uretanowy
plough
overload locking
spring
urethane elastomer
Opis:
Przeprowadzono badania trzech rodzajów lanych elastomerów uretanowych w aspekcie zastosowania jako sprężyn mechanicznych zabezpieczeń pługów. Wytypowano jeden z nich jako spełniający założone wymagania. Wyznaczono jego charakterystykę jako zależność wielkości odkształcenia od wielkości siły sprężającej i odprężającej. Na jej podstawie skonstruowano sprężynę spełniającą stawiane mechanicznym bezpiecznikom pługów uwarunkowania techniczno-użytkowe. Prototypy sprężyn poddano badaniom eksploatacyjnym w trakcie orki zakamienionego gruntu, wyznaczając charakterystykę pracy bezpieczników uzbrojonych w nowe sprężyny. Uzyskane wyniki wskazują na ich przydatność użytkową, a efekty orki odpowiadają efektom stosowania pługów z zabezpieczeniami hydro-pneumatycznymi.
Three kinds of cast urethane elastomers were tested in respect of their application as the springs to mechanical lockings of the ploughs. One of them has been chosen as complying with assumed requirements. Its characteristic was determined as a dependence of strain rate on compressive and decompressive forces. On such a basis the spring was constructed that complied with technical and operation requirements for mechanical lockings of the ploughs. The prototype springs were subjected to oprating tests in the course of ploughing on stony ground; operation characteristic was evaluated for overload lockings equipped with the new springs. The test results proved their usability: the effects of ploughing were equivalent to those obtained at using ploughs with hydro-pneumatic lockings.
Źródło:
Problemy Inżynierii Rolniczej; 2005, R. 13, nr 4, 4; 17-28
1231-0093
Pojawia się w:
Problemy Inżynierii Rolniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Relationship of maximal isometric torque produced in flexors and extensors rate to technique by judo athletes
Autorzy:
Sterkowicz, S.
Lech, G.
Sterkowicz-Przybycień, K.
Chwała, W.
Ambroży, T.
Pałka, T.
Powiązania:
https://bibliotekanauki.pl/articles/307561.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
skład ciała
biomechanika
sport
athletic performance
body composition
biomechanics
martial arts
Opis:
Purpose: Development of strength is one of essential elements of motor preparation of judo athletes. The aim this study was to examine the influence of body composition and the joint torques on successful performance of various judo techniques. Methods: Twentyfive judo athletes participated in 175 judo bouts, which were video-recorded during the All-Polish competitions. Biomechanical classification of technical actions was used. The age and athletic experience of the subjects were 18 and 8.8 years, respectively. Their body height was 179.4 cm (Martin’s type anthropometer) and body mass was 80.3 kg (Sartorius F 1505 – DZA scales). Percentage of fat (10.6%) was estimated using skinfold result measurements. BMI (24.9 kgm–2), fat-free mass index (21.9 kgm–2) and fat mass index (3.0 kgm–2) were calculated. Maximum torques measured under static conditions were evaluated 2–3 days after the tournament. Descriptive statistics and ANOVA were conducted ( p 0.05). Results: Balancing of maximum torques in the muscles of the pelvic and illiac regions caused more frequent performance of physical lever-type throwing techniques, compared to couple of force-type throwing techniques. A negative correlation was found between body fat and value of force recorded for knee flexors and between the frequency of using techniques during groundwork and torques measured in hip extensors. High correlation of fat-free mass index and relative elbow flexor torque was found. Conclusions: The relationship between body composition and frequency of techniques used in a tournament, and joint torques developed by athletes were found.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 2; 65-71
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Time Calibration of the J-PET Detector
Autorzy:
Skurzok, M.
Silarski, M.
Alfs, D.
Białas, P.
Shivani, S.
Curceanu, C.
Czerwiński, E.
Dulski, K.
Gajos, A.
Głowacz, B.
Gorgol, M.
Hiesmayr, B.
Jasińska, B.
Kisielewska-Kamińska, D.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krawczyk, N.
Krzemień, W.
Kubicz, E.
Mohammed, Muhsin
Pawlik-Niedźwiecka, M.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Raj, J.
Rudy, Z.
Sharma, N.
Sharma, S.
Shopa, R.
Wieczorek, A.
Wiślicki, W.
Zgardzińska, B.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/1033283.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
06.20.fb
36.10.Dr
11.30.Er
24.80.+y
Opis:
The Jagiellonian positron emission tomograph project carried out in the Institute of Physics of the Jagiellonian University is focused on construction and tests of the first prototype of PET scanner for medical diagnostic which allows for the simultaneous 3D imaging of the whole human body using organic scintillators. The J-PET prototype consists of 192 scintillator strips forming three cylindrical layers which are optimized for the detection of photons from the electron-positron annihilation with high time-and high angular resolutions. In this article we present time calibration and synchronization of the whole J-PET detection system by irradiating each single detection module with a ²²Na source and a small detector providing common reference time for synchronization of all the modules.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1641-1644
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reconstruction of hit time and hit position of annihilation quanta in the J-PET detector using the Mahalanobis distance
Autorzy:
Sharma, N. G.
Silarski, M.
Bednarski, T.
Białas, P.
Czerwiński, E.
Gajos, A.
Gorgol, M.
Jasińska, B.
Kamińska, D.
Kapłon, Ł.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krzemień, W.
Kubicz, E.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Rudy, Z.
Rundel, O.
Słomski, A.
Strzelecki, A.
Wieczorek, A.
Wiślicki, W.
Zieliński, M.
Zgardzińska, B.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/146937.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
J-PET detector
Mahalanobis distance
time resolution
threshold levels
Opis:
The J-PET detector being developed at the Jagiellonian University is a positron emission tomograph composed of the long strips of polymer scintillators. At the same time, it is a detector system that will be used for studies of the decays of positronium atoms. The shape of photomultiplier signals depends on the hit time and hit position of the gamma quantum. In order to take advantage of this fact, a dedicated sampling front-end electronics that enables to sample signals in voltage domain with the time precision of about 20 ps and novel reconstruction method based on the comparison of examined signal with the model signals stored in the library has been developed. As a measure of the similarity, we use the Mahalanobis distance. The achievable position and time resolution depend on the number and values of the threshold levels at which the signal is sampled. A reconstruction method as well as preliminary results are presented and discussed.
Źródło:
Nukleonika; 2015, 60, No. 4, part 1; 765-769
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tribological Wear Behaviour of Electrical Contacts Made from AgNi10 Composite
Autorzy:
Richert, M. W.
Boczkal, G.
Hotloś, A.
Pałka, P.
Karpiński, M.
Powiązania:
https://bibliotekanauki.pl/articles/355681.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wear behaviour
composite
electrical contact
surface degradation
Opis:
The effect of tribological wear of contacts made from an AgNi10 alloy on microstructure and electrical properties was investigated. The contacts were tested in duty cycles loaded with alternating current of 10A intensity. With this value of the current, intensive arcing of contacts occurred. The contacts were tested in the range of 125 to 500 thousand cycles. The contacting surfaces were reported to suffer a high degree of wear, but electrical resistance of the contact system remained stable.
Źródło:
Archives of Metallurgy and Materials; 2017, 62, 4; 2007-2013
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of the compress sensing theory for improvement of the TOF resolution in a novel J-PET instrument
Autorzy:
Raczyński, L.
Moskal, P.
Kowalski, P.
Wiślicki, W.
Bednarski, T.
Białas, P.
Czerwiński, E.
Gajos, A.
Kapłon, Ł.
Kochanowski, A.
Korcyl, G.
Kowal, J.
Kozik, T.
Krzemień, W.
Kubicz, E.
Niedźwiecki, S.
Pałka, M.
Rudy, Z.
Salabura, P.
Gupta-Sharma, N.
Silarski, M.
Słomski, A.
Smyrski, J.
Strzelecki, A.
Wieczorek, A.
Zieliński, M.
Zoń, N.
Powiązania:
https://bibliotekanauki.pl/articles/146280.pdf
Data publikacji:
2016
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
compressed sensing
positron emission tomography
time-of-flight
Opis:
Nowadays, in positron emission tomography (PET) systems, a time of fl ight (TOF) information is used to improve the image reconstruction process. In TOF-PET, fast detectors are able to measure the difference in the arrival time of the two gamma rays, with the precision enabling to shorten signifi cantly a range along the line-of-response (LOR) where the annihilation occurred. In the new concept, called J-PET scanner, gamma rays are detected in plastic scintillators. In a single strip of J-PET system, time values are obtained by probing signals in the amplitude domain. Owing to compressive sensing (CS) theory, information about the shape and amplitude of the signals is recovered. In this paper, we demonstrate that based on the acquired signals parameters, a better signal normalization may be provided in order to improve the TOF resolution. The procedure was tested using large sample of data registered by a dedicated detection setup enabling sampling of signals with 50-ps intervals. Experimental setup provided irradiation of a chosen position in the plastic scintillator strip with annihilation gamma quanta.
Źródło:
Nukleonika; 2016, 61, 1; 35-39
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena struktury, modułu Younga oraz cytotoksyczności kompozytów na bazie chitozanu
Structural properties, Youngs modulus and cytotoxicity assessment of chitosan-based composites
Autorzy:
Przekora, A.
Pałka, K.
Macherzyńska, B.
Ginalska, G.
Powiązania:
https://bibliotekanauki.pl/articles/283835.pdf
Data publikacji:
2012
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
chitozan
rusztowanie
struktura
moduł Younga
cytotoksyczność
chitosan
scaffold
structure
Young's modulus
cytotoxicity
Opis:
Ceramika wapniowo-fosforanowa w formie porowatego rusztowania na bazie biodegradowalnego biopolimeru jest materiałem powszechnie stosowanym jako wypełniacz ubytków tkanki kostnej w ortopedii i stomatologii. Chitozan, ze względu na swoje charakterystyczne właściwości takie jak: podobieństwo strukturalne do glikozaminoglikanów (GAG) macierzy pozakomórkowej tkanki kostnej, brak toksyczności, szybka biodegradacja, podatność na chemiczną i enzymatyczną modyfikację, stymulacja adhezji i proliferacji komórek oraz osteoinduktywność, jest często stosowany w inżynierii tkankowej kości jako składnik kompozytów. W niniejszej pracy, określono parametry strukturalne i mechaniczne oraz cytotoksyczność typów kompozytów na bazie chitozanu (chitozan-HA BIOCER oraz chitozan-HT BIOCER). Testy in vitro przeprowadzono z wykorzystaniem linii komórkowej hFOB 1.19 (ludzkie płodowe osteoblasty). Cytotoksyczność ekstraktów z kompozytów oznaczono za pomocą testu LDH. Wyniki badań wyraźnie wskazują, że wyprodukowane kompozyty na bazie krylowego chitozanu wykazują dobre parametry strukturalne i mechaniczne o dużej zgodności z tkankami, są nietoksyczne i przez to są obiecującym materiałem do stosowania w inżynierii tkankowej kości.
Calcium phosphate ceramics in the form of biodegradable biopolymer-based, porous scaffolds are widely used as bone defect filler in dentistry and orthopedics. Chitosan is often applied in bone tissue engineering as a component of composites because of its characteristic properties such as structural similarity to glycosaminoglycans (GAG) of bone extracellular matrix, nontoxicity, rapid biodegradation, prone to chemical and enzymatic modification, stimulation of cell adhesion and proliferation and osteoinduction. In this work, the structure, mechanical properties and cytotoxicity of 2 types of chitosan-based composites (chitosan-HA BIOCER and chitosan-HT BIOCER) were evaluated. In vitro cell culture tests were carried out using hFOB 1.19 cell line (human fetal osteoblast cells). The cytotoxicity of scaffolds extracts was estimated by LDH test. Our studies clearly indicate that created krill chitosan-based composites show good structural and mechanical properties with good compatibility with human tissues. Furthermore, produced composites are nontoxic and thus are promising materials for bone tissue engineering application.
Źródło:
Engineering of Biomaterials; 2012, 15, 114; 52-58
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary studies of J-PET detector spatial resolution
Autorzy:
Pawlik-Niedźwiecka, M.
Niedźwiecki, S.
Alfs, D.
Białas, P.
Curceanu, C.
Czerwiński, E.
Dulski, K.
Gajos, A.
Głowacz, B.
Gorgol, M.
Hiesmayr, B.
Jasińska, B.
Kisielewska, D.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krawczyk, N.
Krzemień, W.
Kubicz, E.
Mohammed, M.
Pałka, M.
Raczyński, L.
Raj, J.
Rudy, Z.
Shivani, -
Silarski, M.
Skurzok, M.
Sharma, N.
Sharma, S.
Shopa, R.
Strzelecki, A.
Wieczorek, A.
Wiślicki, W.
Zgardzińska, B.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/1057928.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
29.40.Mc
87.57.uk
87.10.Rt
34.50.-s
Opis:
The J-PET detector, based on long plastic scintillator strips, was recently constructed at the Jagiellonian University. It consists of 192 modules axially arranged into three layers, read out from both sides by digital constant-threshold front-end electronics. This work presents preliminary results of measurements of the spatial resolution of the J-PET tomograph performed with ²²Na source placed at selected position inside the detector chamber.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1645-1648
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Molecular Dynamics Simulations of Energetic Ar Cluster Bombardment of Ag(111)
Autorzy:
Palka, G.
Rzeznik, L.
Paruch, R.
Postawa, Z.
Powiązania:
https://bibliotekanauki.pl/articles/1400436.pdf
Data publikacji:
2013-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
68.49.Sf
82.80.Ms
83.10.Rs
79.20.Rf
Opis:
Large-scale molecular dynamics computer simulations are used to investigate the dynamics of material ejection during high-energy $Ar_n$ cluster bombardment of Ag(111) at normal incidence. The silver sample containing 7 million atoms is bombarded with $Ar_n$ projectiles (n=45-30000) with kinetic energy spanning from a few keV up to 1 MeV. Such a wide range of projectile parameters allows probing processes taking place during low-density collision cascade as well as during high-density events characteristic of micrometeorite bombardment in space. The material modifications and total sputtering yield of ejected particles are investigated. While at low-energy impacts, ejection of individual silver atoms is the main emission channel, the ejection of large clusters from the corona of the created crater dominates for the high-energy impacts.
Źródło:
Acta Physica Polonica A; 2013, 123, 5; 831-833
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of mass parameters of the body on active safety of a fire engine in terms of the selection of chassis
Autorzy:
Nogowczyk, P.
Pałka, A.
Szczęśniak, G.
Powiązania:
https://bibliotekanauki.pl/articles/263479.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz. Przemysłowy Instytut Motoryzacji
Tematy:
special vehicles
centre of masses parameters
steering characteristics
dynamic lateral
stability
braking forces
pojazd specjalny
stateczność
siła hamowania
Opis:
The position of the centre of masses affects the distribution of wheel loads and, at the same time, the stability of the vehicle in drive on bends as well as the course (intensity and efficiency) of braking. For fire engines heading for the site of emergency, these are important properties regarding performance. The paper presents a simplified factor analysis of the influence of the centre of masses position in special vehicles with fire fighting bodywork on the characteristics of steering, lateral stability and braking forces. A relation between the transfer function and the driving speed has been presented and the influence of the distance between the centre of masses from the rear axle of the vehicle on its steerability has been analysed. With the examples of given vehicles, it has been shown to what extent the mentioned indices and parameters can be changed after equipping a standard truck chassis with our bodywork system. The information contained herein may be useful for the construction departments of specialized vehicle bodywork manufacturers.
Źródło:
Archiwum Motoryzacji; 2018, 82, 4; 87-98
1234-754X
2084-476X
Pojawia się w:
Archiwum Motoryzacji
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies