Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Pajek, J." wg kryterium: Autor


Wyświetlanie 1-4 z 4
Tytuł:
Is there a need for a weight management control program in hemodialysis patients? The implication of exercise programs
Czy jest potrzeba stosowania programu kontroli wagi u pacjentów poddawanych hemodializie? Wykorzystanie programów ćwiczeń
Autorzy:
Bogataj, S.
Pajek, J.
Ponikvar, J.B.
Pajek, M.
Powiązania:
https://bibliotekanauki.pl/articles/2048840.pdf
Data publikacji:
2021
Wydawca:
Akademia Bialska Nauk Stosowanych im. Jana Pawła II w Białej Podlaskiej
Tematy:
hemodialysis
body composition
functional training
intradialytic cycling
impact
Opis:
Background. In hemodialysis (HD) patients, age-related muscle loss and body composition changes are more intense than in those with normal renal function. This study aimed to determine the effects of functional training in addition to intradialytic cycling exercise, compared to intradialytic cycling alone on body composition in HD patients. Material and methods. Patients were randomized to an experimental group (n=20; functional training and intradialytic cycling) or control group (n=20; intradialytic cycling) over 16 weeks. In the first 8 weeks, the experimental group attended guided functional training before dialysis, and afterward performed functional training at home. Results. After 16 weeks, a significant intergroup difference was found only in total body water only (p=0.037) in favor of the experimental group. Significant intragroup changes were found for weight (after 8 weeks: p=0.009; after 16 weeks: p=0.012), waist circumference (after 8 weeks: p=0.026; after 16 weeks: p=0.044), and BMI (after 16 weeks: p=0.046) in the experimental group and for fat tissue index (after 16 weeks: p=0.038) in the control group. Overall exercise compliance was high, reaching more than two-thirds of prescribed exercise volumes. Conclusions. Our results showed increased weight and BMI following functional training in HD patients. This increase was not a result of an increase in body fat, which was illustrated by unchanged results in fat tissue index.
Wprowadzenie. U pacjentów poddawanych hemodializie związane z wiekiem utrata mięśni i zmiany w składzie ciała są bardziej intensywne niż u osób z prawidłowym funkcjonowaniem nerek. Celem badania było określenie wpływu treningu funkcjonalnego jako dodatku do śróddializacyjnych ćwiczeń na rowerze w porównaniu z samymi śróddializacyjnymi ćwiczeniami na rowerze na skład ciała pacjentów poddawanych hemodializie. Materiał i metody. Pacjenci zostali losowo przypisani do grupy doświadczalnej (n=20, trening funkcjonalny i śróddializacyjna jazda na rowerze) albo kontrolnej (n=20, śróddializacyjna jazda na rowerze) na 16 tygodni. Przez pierwszych osiem tygodni grupa doświadczalna uczestniczyła w prowadzonych przez trenera treningach funkcjonalnych przed poddaniem się dializie i wykonywała trening funkcjonalny w domu. Wyniki. Po 16 tygodniach pomiędzy grupami zaszła istotna zmiana w zakresie całkowitej zawartości wody w ciele (p=0,037) na korzyść grupy doświadczalnej. Wykazano zasadnicze różnice między grupami w zakresie wagi (po 8 tygodniach: p=0,009; po 16 tygodniach: p=0,012), obwodu pasa (po 8 tygodniach: p=0,026; po 16 tygodniach p=0,044) i wartości BMI (po 16 tygodniach: p=0,046) w grupie doświadczalnej oraz w zakresie wskaźnika tkanki tłuszczowej (po 16 tygodniach: p=0,038) w grupie kontrolnej. Ogólna zgodność ćwiczeń była wysoka i sięgała ponad 2/3 przepisanych ćwiczeń. Wnioski. Wyniki wykazały zwiększoną wagę i BMI w następstwie treningu funkcjonalnego u pacjentów poddawanych dializoterapii. Wzrost ten nie był efektem zwiększenia zawartości tłuszczu w ciele, co potwierdził brak zmian we wskaźniku tkanki tłuszczowej.
Źródło:
Health Problems of Civilization; 2021, 15, 1; 29-36
2353-6942
2354-0265
Pojawia się w:
Health Problems of Civilization
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
X-ray Diffraction and Elemental Analysis of Medical and Environmental Samples
Autorzy:
Bielecka, K.
Kurtek, W.
Banaś, D.
Kubala-Kukuś, A.
Braziewicz, J.
Majewska, U.
Pajek, M.
Wudarczyk-Moćko, J.
Stabrawa, I.
Powiązania:
https://bibliotekanauki.pl/articles/1197663.pdf
Data publikacji:
2014-04
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
78.70.En
87.64.Bx
32.30.Rj
87.64.kv
Opis:
The results of the elemental and chemical composition analysis of human medical samples (blood, serum, hair, urine, tooth, kidney stones, gallstones) and environmental samples (slag, cereal, vegetables, flour, pork bones, pork meat, fish) are presented. The analysis were performed by application of the total reflection X-ray fluorescence, wavelength dispersive X-ray fluorescence and X-ray powder diffraction methods. With X-ray fluorescence methods the following elements were identified: O, Na, Mg, Al, Si, P, S, Cl, K, Ca, Ti, Mn, Fe, Ni, Cu, Zn, Se, Br, Rb, Sr, Zr, I, Ba, and Pb, whose concentrations were from a few ng/g to tens of percent. For some samples the elemental analysis was extended by X-ray powder diffraction measurements. With this method the chemical composition was determined. In the paper the experimental setups, methodology of samples preparation and methods of carrying out the measurements are described. As an example the X-ray spectra registered for gallstone sample are discussed in detail. Finally, the results of X-ray diffraction and elemental analysis for selected medical and environmental samples are summarized.
Źródło:
Acta Physica Polonica A; 2014, 125, 4; 911-918
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of Gold Nanolayer Properties Using X-Ray Reflectometry and Spectroscopic Ellipsometry Methods
Autorzy:
Stabrawa, I.
Banaś, D.
Dworecki, K.
Kubala-Kukuś, A.
Braziewicz, J.
Majewska, U.
Wudarczyk-Moćko, J.
Pajek, M.
Góźdź, S.
Powiązania:
https://bibliotekanauki.pl/articles/1398825.pdf
Data publikacji:
2016-02
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
61.05.cm
62.23.St
68.55.-a
81.07.-b
Opis:
X-ray reflectometry and spectroscopic ellipsometry methods were applied for determination of physical properties of gold nonolayers. The nanolayers were prepared by sputtering of gold on different substrates: borosilicate glass, polished crystalline quartz and crystalline silicon. With X-ray reflectometry technique roughness of the substrates and density, thickness and roughness of gold layers were determined. The results showed decrease in density of the gold layers due to their nanometer thickness and that roughness of the underlayer affects roughness of the gold layer. In addition, thicknesses of the gold layers measured with spectroscopic ellipsometry turned out to be in agreement, within the experimental uncertainty, with results of the X-ray reflectometry method.
Źródło:
Acta Physica Polonica A; 2016, 129, 2; 233-236
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
X-Ray Fluorescence Techniques in Medical Applications: Reference Values of Elements in Human Serum, Urine and Hair
Autorzy:
Majewska, U.
Banaś, D.
Braziewicz, J.
Kubala-Kukuś, A.
Pajek, M.
Sychowska, I.
Wudarczyk-Moćko, J.
Antczak, G.
Borkowska, B.
Góźdź, S.
Powiązania:
https://bibliotekanauki.pl/articles/1197643.pdf
Data publikacji:
2014-04
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
32.30.Rj
87.64.kd
87.64.kv
Opis:
The aim of undertaken long-term studies of the elemental composition of human serum, urine, and hair is to define reference values of elements concentration. For this purpose the total reflection X-ray fluorescence method was applied to determination of several elements concentration in human serum, urine and hair (S, K, Ca, Fe, Cu, Zn, Br, P, Cr, and Rb in serum samples; Fe, Cu, Zn, Rb, Cr, Mn, and Sr in urine samples; S, K, Ca, Fe, Cu, Br, Zn, Cl, Ti, Cr, Mn, Ni, and Se in hair samples) in the range of concentration from ppb to several hundred ppm. The method of selection of the control group, the experimental setup and its calibration procedure are described. We also present sample preparation methods and procedure of measurements.
Źródło:
Acta Physica Polonica A; 2014, 125, 4; 864-868
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies