Tytuł:
Microstructural Changes of Ods Ferritic Steel Powders During Mechanical Alloying
Autorzy:
Oksiuta, Z.
Powiązania:
https://bibliotekanauki.pl/articles/387304.pdf
Data publikacji:
2011
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
stal ferrytyczno-perlityczna
metalurgia proszków
mechaniczne stapianie
ferritic-pearlitic steel
powder metallurgy
mechanical alloying
Opis:
The ODS ferritic steel powder with chemical composition of Fe-14Cr-2W-0.3Ti-0.3Y2O3 was mechanically alloyed (MA) either from elemental or pre-alloyed powders in a planetary ball mill. Different milling parameters have been used to investigate their influence on the morphology and microstructure of the ODS ferritic steel powder. The time of MA was optimized by studying the structural evolution of the powder by means of X-ray diffractometry and TEM. In the case of elemental powder very small, about 10 žm in diameter, spherical particles with a large surface area have been obtained. Flakey-like particles with an average size of about 45 žm were obtained in the case of the pre-alloyed powder. The lattice strain calculated from XRD spectra of the elemental and pre-alloyed powders exhibits a value of about 0.51 % and 0.67, respectively. The pre-alloyed powder after consolidation process showed the highest density and microhardness value.
Źródło:
Acta Mechanica et Automatica; 2011, 5, 2; 74-78
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of corrosion resistance in physiological saline solution of two austenitic stainless steels – 316LV and REX734
Autorzy:
Romańczuk, E.
Oksiuta, Z.
Powiązania:
https://bibliotekanauki.pl/articles/387266.pdf
Data publikacji:
2017
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
REX734 austenitic stainless steel
316 LV austenitic stainless steel
potentiodynamic corrosion tests
XRD analysis
SEM observation
Opis:
In this work two austenitic stainless steels, REX734 and 316LV were tested in terms of their microstructure and corrosion properties. The REX734 is a newer generation stainless steel, with modified chemical composition, in comparison to the 316LV grade. Potentiodynamic study of corrosion resistance was conducted in physiological saline solution (0.9% NaCl solution). In spite of the similarities of microstructure, grain size and phase structure in both materials, the corrosion tests revealed that the REX734, with lower nickel and higher nitrogen content, had better corrosion resistance than 316LV. Repassivation potential in the REX734 was almost six times higher than for the 316LV steel. Superior corrosion resistance of the REX734 steel was also confirmed by surface observations of both materials, since bigger and more densely distributed pits were detected in 316LV alloy.
Źródło:
Acta Mechanica et Automatica; 2017, 11, 2; 91-95
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
XRD and morphology analyzes of high-nitrogen Fe-Cr-Mn alloy powders synthesized by mechanical alloying
Autorzy:
Romańczuk, E.
Oksiuta, Z.
Powiązania:
https://bibliotekanauki.pl/articles/285796.pdf
Data publikacji:
2016
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
biomaterials
morphology
XRD analysis
Źródło:
Engineering of Biomaterials; 2016, 19, 138; 95
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Corrosion Resistance of Mechanically Alloyed 14% Cr ODS Ferritic Steel
Autorzy:
Oksiuta, Z.
Och, E.
Powiązania:
https://bibliotekanauki.pl/articles/386927.pdf
Data publikacji:
2013
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
stal ferrytyczna ODS
stal austenityczna
testy korozyjne
korozja wżerowa
ODS ferritic steel
316 LV austenitic stainless steel
potentiodynamic corrosion tests
pitting corrosion
Opis:
New classes of singular fractional continuous-time and discrete-time linear systems are introduced. Electrical circuits are example of singular fractional continuous-time systems. Using the Caputo definition of the fractional derivative, the Weierstrass regular pencil decomposition and Laplace transformation the solution to the state equation of singular fractional linear systems is derived. It is shown that every electrical circuit is a singular fractional systems if it contains at least one mesh consisting of branches with only ideal supercondensators and voltage sources or at least one node with branches with supercoils. Using the Weierstrass regular pencil decomposition the solution to the state equation of singular fractional discrete-time linear systems is derived. The considerations are illustrated by numerical examples.
Źródło:
Acta Mechanica et Automatica; 2013, 7, 1; 38-41
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Failure analysis of a femoral hip stem made of stainless steel after short time of exposure
Autorzy:
Mierzejewska, Ż. A.
Oksiuta, Z.
Powiązania:
https://bibliotekanauki.pl/articles/386661.pdf
Data publikacji:
2014
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
hip replacement
endoprosthesis stem fracture
isolated fracture
total hip arthroplasty complications
fatigue fracture
proteza stawu biodrowego
endoproteza
pękanie zmęczeniowe
Opis:
This paper describes a case study summarising the failure analysis of a stainless steel femoral stem, which failed prematurely within 36 months of exploitation in human body. In order to determine the mechanism of failure, a broken stem component were analyzed by means of macroscopic and microscopic obserwations and hardness measurements. Metallurgical obserwations revealed that the tested material does fulfill ASTM requirements. Scanning electron microscopy images revealed the presence of stress-induced cracking. The results of the hardness revealed significant nonuniformity from the surface towards the inner part of the stem. It is assumed that any discontinuity or defect on the fracture surface of the stem acted as preferential site for a crack nucleation and propagation by fatigue until the cross section of stem was not able to sustain a load generated by a patient.
Źródło:
Acta Mechanica et Automatica; 2014, 8, 3; 146-150
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Izolowane złamanie trzpienia endoprotezy stawu biodrowego – opis dwóch przypadków
Isolated fracture of the hip stem prosthesis – report of two cases
Autorzy:
Mierzejewska, Ż. A.
Oksiuta, Z.
Powiązania:
https://bibliotekanauki.pl/articles/970914.pdf
Data publikacji:
2014
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
endoprotezoplastyka
złamanie izolowane
powikłania po całkowitej artroplastyce
reimplantacja
endoprosthesoplasty
isolated stem fracture
complications of total hip arthroplasty
reimplantation
Opis:
Staw biodrowy zbudowany jest z panewki biodrowej, anatomicznie uformowanej z kości miednicy oraz głowy kości udowej. Oba te elementy pokryte są chrząstką i otoczone torebką stawową, wypełnioną płynem synowialnym, którego zadaniem jest odżywianie chrząstki oraz amortyzowanie sił działających na staw. Jakiekolwiek zmiany w tym układzie mogą prowadzić do uszkodzenia i deformacji stawu, co skutkuje utratą funkcjonalności oraz bólem. Terapią, która przywraca pacjentowi możliwość bezbolesnego funkcjonowania jest endoprotezoplastyka, polegająca na chirurgicznym wycięciu zmienionych chorobowo powierzchni stawowych i zastąpieniu ich sztucznymi elementami. Jednakże, jak każda chirurgiczna interwencja, endoprotezoplastyka niesie ze sobą ryzyko powikłań. Jednym z nich jest izolowane złamanie trzpienia stawu biodrowego – trzpień ulega złamaniu w kanale szpikowym przy czym tkanki otaczające implant nie zostają uszkodzone. W pracy przedstawione i porównane zostały dwa przypadki izolowanego złamania trzpienia endoprotezy stawu biodrowego, rozpoznane ok. 3 lata po wszczepieniu implantów. Celem pracy było zbadanie cech i mikrostruktury reimplantowanych trzpieni, zdefiniowanie relacji pomiędzy strukturą a wielkością ziaren i zidentyfikowanie ognisk pękania. W tym celu zbadane zostały mikrostruktura, wielkość ziaren, skład chemiczny oraz twardość obu trzpieni. Badania mikroskopowe ujawniły defekty materiału. Obserwacje przełomu za pomocą skaningowego mikroskopu elektronowego (SEM) ujawniły obecność prążków zmęczeniowych, co wskazuje na zmęczeniowy charakter przełomu. Liniowy pomiar twardości ujawnił znaczną niejednorodność materiału. Uzyskane wyniki stanowią podstawę do dalszych badań tego zjawiska.
The hip joint is composed of acetabular, anatomical surface of pelvis and the femoral head. Both of these elements are covered with cartilage and enclosed in a capsule, filled with synovium, which aim is to nourish the cartilage and depreciate forces acting on the hip joint. Any lesions in this system can lead to damage and deformation of the joint, which results in loss of function and pain. The treatment that restores the patient’s ability to functioning is the total hip replacement, which consists of surgical excision of the damaged joint surface and implanted in place of artificial elements. However, like any surgical intervention, this procedure carried the risk of complications. One of them is isolated stem fracture, which consisting of the stem break inside the medullary canal without damaging surrounding tissue. The work presents and compares two cases of isolated fracture of hip stems, which were recognized three years after the operation. The aim of the study was to investigate the properties and microstructure of reimplanted stems, made of austenitic, to define the relationship between the structure and the size of the grains and to identify outbreaks of cracking. Microstructure, grain size, chemical composition and hardness of both stems have been investigated. Microscopic examination revealed defects in material. A breakthrough observation, carried out by scanning electron microscopy (SEM) revealed the presence of fatigue striations, which clearly indicated the nature of the fatigue fracture. Linear hardness measurements revealed significant heterogeneity of the material. The results obtained in this work will be used for further research on this topic.
Źródło:
Engineering of Biomaterials; 2014, 17, no. 128-129; 28-31
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies