Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Kopeć, G." wg kryterium: Autor


Wyświetlanie 1-7 z 7
Tytuł:
Sterility of Miscanthus xgiganteus results from hybrid incompatibility
Autorzy:
Slomka, A.
Kuta, E.
Plazek, A.
Dubert, F.
Zur, I.
Dubas, E.
Kopec, P.
Zurek, G.
Powiązania:
https://bibliotekanauki.pl/articles/19177.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Opis:
Miscanthus ×giganteus Greef et Deu. (Poaceae), a hybrid of Miscanthus sinensis and M. sacchariflorus native to Japan, is an ornamental and a highly lignocellulosic bioenergy crop, cultivated in the European Union as an alternative source of energy. This grass reproduces exclusively vegetatively, by rhizomes or via expensive in vitro micropropagation. The present study was aimed at finding the barriers that prevent sexual seed production, based on detailed embryological analyses of the whole generative cycle, including microsporogenesis, pollen viability, megasporogenesis, female gametophyte development, and embryo and endosperm formation. Sterility of M. ×giganteus results from abnormal development of both male and female gametophytes. Disturbed microsporogenesis (laggard chromosomes, univalents, micronuclei) was further highlighted by low pollen staining. The frequency of stainable pollen ranged from 13.9% to 55.3% depending on the pollen staining test, and no pollen germination was observed either in vitro or in planta. The wide range of pollen sizes (25.5–47.6 μm) clearly indicated unbalanced pollen grain cytology, which evidently affected pollen germination. Only 9.7% of the ovules developed normally. No zygotes nor embryos were found in any analyzed ovules. Sexual reproduction of M. ×giganteus is severely hampered by its allotriploid (2n=3x=57) nature. Hybrid sterility, a strong postzygotic barrier, prevents sexual reproduction and, therefore, seed formation in this taxon.
Źródło:
Acta Biologica Cracoviensia. Series Botanica; 2012, 54, 1
0001-5296
Pojawia się w:
Acta Biologica Cracoviensia. Series Botanica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary studies of polymorphism of selected microsatellite sequences in different colour types of raccoon dog (Nyctereutes Procyonoides)
Wstępne badania polimorfizmu wybranych sekwencji mikrosatelitarnych różnie umaszczonych jenotów (Nyctereutes procyonoides)
Autorzy:
Jakubczak, A.
Jeżewska-Witkowska, G.
Horecka, B.
Żelazowska, M.
Kopeć, E.
Rupeć, Z.
Powiązania:
https://bibliotekanauki.pl/articles/2197064.pdf
Data publikacji:
2012
Wydawca:
Uniwersytet Przyrodniczy w Lublinie. Wydawnictwo Uniwersytetu Przyrodniczego w Lublinie
Źródło:
Annales Universitatis Mariae Curie-Skłodowska. Sectio EE: Zootechnica; 2012, 30, 4; 41-48
0239-4243
2083-7399
Pojawia się w:
Annales Universitatis Mariae Curie-Skłodowska. Sectio EE: Zootechnica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
On the nature of changes in the optical characterization produced in sapphire on its irradiation with a pulsed powerful stream of hydrogen ions
Autorzy:
Gribkov, V.
Ivanov, L.
Maslyaev, S.
Pimenov, V.
Sadowski, M.
Skladnik-Sadowska, E.
Banaszak, A.
Kopeć, G.
Cheblukov, Y.
Kozodaev, M. A.
Suvorov, A. L.
Smirnov, I. S.
Powiązania:
https://bibliotekanauki.pl/articles/147991.pdf
Data publikacji:
2004
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
optical characteristics
irradiation
fast ion stream
morphology
Opis:
Changes in the optical characteristics in synthetic sapphire specimens produced by microsecond pulse irradiation with a stream of hydrogen ions of energies ranging up to tens keV have been observed. Data on decrease in the optical reflection, measured within the wavelength range of 200 900 nm, are presented. This characterization is compared with the data received by optical and atomic force microscopy as well as by lattice structure analysis performed with X-rays. The measurements indicate that the changes of optical parameters are not a consequence of absorption increase and/or sapphire decomposition. They result from modifications of the morphology and structure of surface layer of the sapphire samples, induced by irradiation.
Źródło:
Nukleonika; 2004, 49, 2; 43-49
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kinematic gait parameters changes in patients after total knee arthroplasty : Comparison between cruciate-retaining and posterior-substituting design
Autorzy:
Hajduk, G.
Nowak, K.
Sobota, G.
Kusz, D.
Kopeć, K.
Błaszczak, E.
Cieliński, Ł.
Bacik, B.
Powiązania:
https://bibliotekanauki.pl/articles/306649.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
staw kolanowy
endoprotezoplastyka
analiza lokomocji
total knee arthroplasty
gait analysis
cruciate retaining
posterior substituting
Opis:
Purpose: The patients expect optimal knee function after Total Knee Arthroplasty. It is necessary to apply appropriate surgical technique and supervised physical therapy. The optimal management of posterior cruciate ligament remains controversial. Both implant designs, i.e., cruciate retaining and posterior substituting, allow the orthopedic surgeon to achieve excellent clinical outcomes, as measured by commonly used questionnaires. Such methods of assessment may poorly reflect the functional status of patients. Therefore, three-dimensional gait analysis is recommended to evaluate the outcomes of surgical intervention. This study sought to determine differences in kinematic gait parameters and Knee Society Score between cruciate-retaining and posterior-substituting patients. Methods:23 individuals after cruciate-retaining total knee arthroplasty and 19 individuals after posterior-substituting total knee arthroplasty were subjected to gait analysis using three-dimensional motion capture system BTS Smart DX 7000. In addition, gait was assessed in 21 patients with knee osteoarthritis and in 30 healthy individuals. Results: The study did not reveal differences between cruciate-retaining and posterior-substituting groups, both in terms of Knee Society Score and kinematic gait parameters. There were also no differences in kinematic gait parameters between patients from the knee osteoarthritis group and total knee arthroplasty groups. The analyzed parameters in all of the groups differed significantly from those found in healthy individuals. Conclusions: Surgical technique and implant design do not affect values of kinematic gait parameters evaluated under natural walking speed. Several months after surgery the patients still demonstrated alterations in gait pattern, similar to those recorded in patients with knee osteoarthritis.
Źródło:
Acta of Bioengineering and Biomechanics; 2016, 18, 3; 137-142
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identification of the causes of increased vibrations in the high-power multi-stage rotodynamic pump
Identyfikacja przyczyn podwyższonego poziomu drgań wielostopniowej pompy wirowej dużej mocy
Autorzy:
Żywica, G.
Flaszyński, P.
Kaczmarczyk, T. Z.
Kopeć, H.
Powiązania:
https://bibliotekanauki.pl/articles/327870.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
vibrodiagnostics
pump vibrations
rotodynamic pump
high-power pump
wibrodiagnostyka
drgania
pompa wirowa
pompa dużej mocy
Opis:
The article discusses the vibrodiagnostic tests of a multi-stage high-power rotodynamic pump. The tested pump was operated as a feed water pump in an industrial combined heat and power plant. However, some time ago, its dynamic performance started to deteriorate. Therefore, diagnostic tests were carried out, the aim of which was to identify the reasons for the increased vibration level and to minimise it. The scope of the performed work included both the analysis of possible excitation forces originating from the flow system and measurements of the pump vibrations at different power levels. Additionally, at selected measuring points, vibration velocity spectra were registered and eigenfrequencies were determined. The analysis of the obtained results allowed to clearly identify the causes of dynamic problems and introduce changes that enable their elimination.
W artykule omówione zostały badania wibrodiagnostyczne wielostopniowej pompy wirowej o mocy 3 MW. Badana pompa pracowała jako pompa wody zasilającej w elektrociepłowni przemysłowej, ale od pewnego czasu jej stan dynamiczny pogarszał się. Dlatego przeprowadzone zostały badania diagnostyczne, których celem była identyfikacja przyczyn podwyższonego poziomu drgań oraz ich minimalizacja. Zakres wykonanych prac obejmował zarówno analizę możliwych wymuszeń pochodzących z układu przepływowego jak i pomiary wielkości charakterystycznych drgań pompy przy różnych poziomach mocy. Dodatkowo, w wybranych punktach pomiarowych, zarejestrowano również rozkłady częstotliwościowe drgań i wyznaczono częstotliwości drgań własnych. Analiza uzyskanych wyników pozwoliła na jednoznaczną identyfikację przyczyn problemów dynamicznych oraz wprowadzenie zmian umożliwiających ich eliminację.
Źródło:
Diagnostyka; 2018, 19, 3; 81-88
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detection of inner defects in industrial pipelines using transient IR thermography
Autorzy:
Kopeć, M.
Chatzipanagiotou, P.
De Mey, G.
Więcek, B.
Powiązania:
https://bibliotekanauki.pl/articles/114312.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
infrared thermography
transient thermal testing
defect detection
polypropylene pipe
Opis:
A long time operation of pipelines can lead to the reduction of their wall thickness. This process is accelerated by high temperature and variable pressure of the transported medium and can finally cause mechanical failures along with leaks and danger of explosion. The aim of this paper is to present a new method for the detection of abraded walls in industrial pipelines using the time-frequency analysis. The results of transient temperature measurements are used for the calculation of the thermal time constants corresponding - as demonstrated - to the pipeline wall thickness.
Źródło:
Measurement Automation Monitoring; 2017, 63, 3; 115-118
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A new software tool for transient thermal analysis based on fast IR camera temperature measurement
Autorzy:
Chatzipanagiotou, P.
Strąkowska, M.
De Mey, G.
Chatziathanasiou, V.
Więcek, B.
Kopeć, M.
Powiązania:
https://bibliotekanauki.pl/articles/114612.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
transient thermal analysis
IR thermography
Nyquist plot
time constants
cumulative structure function
Opis:
A new software tool for transient thermal analysis based on thermographic measurement of temperature is presented. In the proposed approach, temperature change after applying or removing power can be measured by a thermal camera or any contact temperature sensor. The software calculates thermal impedance in frequency domain and represents it in the form of the Nyquist plot. In addition, thermal time constant spectrum and cumulative structure function are evaluated. The software was developed in Matlab environment using in-built procedures for transfer function estimation. For the validation of the proposed tool, the results are compared with ones obtained using commercially available software.
Źródło:
Measurement Automation Monitoring; 2017, 63, 2; 48-51
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies