Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Kaźmierczak, R." wg kryterium: Autor


Tytuł:
Analysis of the Possibilities for Applying the ASG-EUPOS System Services for Establishing the Detailed Control Networks
Analiza możliwości wykorzystania serwisów systemu ASG-EUPOS do zakładania szczegółowych osnów geodezyjnych
Autorzy:
Bakuła, M.
Kaźmierczak, R.
Grunwald, G.
Powiązania:
https://bibliotekanauki.pl/articles/298225.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Warmińsko-Mazurski w Olsztynie
Tematy:
NAWGEO
POZGEO
POZGEO-D
ASG-EUPOS
RTK
GPS
GLONASS
Opis:
The paper presents analyses and comparisons of coordinates' determination accuracy using ASG-EUPOS system real time (NAWGEO) and post-processing (POZGEO and POZGEO-D) services in the context of establishing detailed control networks. The survey of the detailed land survey network was conducted during construction of the national road S22 in its section Elbląg-Chruściel. At the first stage of the research static GNSS surveys were conducted using four Topcon HiPer Pro receivers. Almost all the points of the land survey network were stabilized in location with good availability to satellites. Only in the vicinity of some points, at the distance of around 10 meters, trees were situated. Processing of the observations was conducted by post-processing using the Topcon Tools software for 30-40 minute sessions using the observations from the network of fixed reference stations of POZGEO-D service. Additional static sessions were also processed using the POZGEO service. At the second stage of the study, RTK surveys using the ASG-EUPOS system NAWGEO service by applying two Topcon HiPer Pro receivers where one of them determined the position on the base of the single physical reference station while the other used the VRS network observations were conducted on the same points of the detailed network. The paper contains comparative analyses of the coordinates obtained and of their accuracy.
W pracy przedstawiono analizy i porównania dokładności wyznaczeń współrzędnych z wykorzystaniem serwisów czasu rzeczywistego (NAWGEO) i postprocessingu (POZGEO i POZGEO-D) systemu ASG-EUPOS w kontekście zakładania szczegółowych osnów geodezyjnych. Pomiar szczegółowej osnowy geodezyjnej wykonano podczas budowy drogi krajowej S22, na odcinku Elbląg - Chruściel. W pierwszym etapie badań wykonano pomiary statyczne GNSS z wykorzystaniem 4 odbiorników Topcon HiperPro. Prawie wszystkie punkty osnowy geodezyjnej były stabilizowane w miejscach o dobrym dostępie do satelitów. Tylko w pobliżu niektórych punktów w odległościach około 10 metrów znajdowały się drzewa. Obserwacje opracowano w procesie postprocessinu z wykorzystaniem oprogramowania firmowego Topcon Tools, dla sesji 30-40-minutowych, z wykorzystaniem obserwacji sieci stacji referencyjnych serwisu POZGEO-D. Dodatkowo sesje statyczne opracowano także z wykorzystaniem serwisu POZGEO. W drugim etapie badań, na tych samych punktach osnowy szczegółowej, przeprowadzono pomiary RTK z wykorzystaniem serwisu NAWGEO systemu ASG-EUPOS dwoma odbiornikami Topcon HiperPro - jeden z nich wyznaczał pozycję na podstawie pojedynczej fizycznej stacji referencyjnej, natomiast drugi z wykorzystaniem sieciowych obserwacji VRS. Praca zawiera analizy porównawcze otrzymanych współrzędnych i ich dokładności.
Źródło:
Technical Sciences / University of Warmia and Mazury in Olsztyn; 2011, 14(2); 217-228
1505-4675
2083-4527
Pojawia się w:
Technical Sciences / University of Warmia and Mazury in Olsztyn
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Iron Containing Supplement Biofer Investigated by X-ray Fluorescence, Energy Dispersive X-Ray Spectroscopy and Mössbauer Spectroscopy
Autorzy:
Brzozowski, R.
Szałański, P.
Kaźmierczak, J.
Polański, K.
Pruba, M.
Moneta, M.
Powiązania:
https://bibliotekanauki.pl/articles/1402229.pdf
Data publikacji:
2015-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
61.05.Qr
78.70.En
87.14.Pq
Opis:
Iron, an important microelement essential to the functioning of the body, plays a special role in the process of respiration. There are more and more new products available on the pharmaceutical market. Some of them were the subject of previous studies, especially by using the Mössbauer spectroscopy. One of the latest is Biofer. For the present tests three tablets from three different production series of Biofer were used for examination of elemental composition using the X-ray fluorescence and energy dispersive X-ray spectroscopy methods. Information about oxidation of iron contained in the tablets was obtained with by means of the Mössbauer spectroscopy.
Źródło:
Acta Physica Polonica A; 2015, 128, 5; 905-907
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Serwisy nawigacyjne systemu ASG-EUPOS - wady i zalety wykorzystania w systemie monitorowania
The navigation services of ASG-EUPOS system - advantages and disadvantages of using these services in monitoring system
Autorzy:
Ciećko, A.
Kaźmierczak, R.
Grunwald, G.
Oszczak, S.
Grzegorzewski, M.
Ćwiklak, J.
Powiązania:
https://bibliotekanauki.pl/articles/270359.pdf
Data publikacji:
2011
Wydawca:
Centralny Ośrodek Badawczo-Rozwojowy Aparatury Badawczej i Dydaktycznej, COBRABiD
Tematy:
serwisy nawigacyjne
nawigacja
ASG-EUPOS
navigation services
Opis:
W codziennym życiu każdego człowieka istotną rolę stanowi wiedza o lokalizacji. Systemy satelitarne pomagają nam w określeniu pozycji. Wykorzystanie w podróży najprostszego odbiornika GNSS zwiększa na trasie poczucie pewności i bezpieczeństwa. Coraz częściej potrzebna nam jest informacja o pozycji z dokładnością decymetrową, którą teoretycznie zapewnia nam metoda DGNSS. Najważniejszym zadaniem nawigacji jest efektywne i bezpieczne dotarcie do celu. Podniesienie tak ważnego elementu jakim jest bezpieczeństwo (szczególnie w lotnictwie), zapewnia system monitorowania. Artykuł przedstawia analizy związane z możliwością wykorzystania serwisów nawigacyjnych ASG-EUPOS w lotnictwie i systemach monitorowania.
Knowledge about location is very important in everyone's life. The satellite systems help us in calculation of position. Utilization of simple GNSS receiver increases self-confidence and safety. Today the need of information about the position with decimeter accuracy is often expected. This can be provided by DGNSS method. Effective and safe travel to target is the most important task in navigation. The monitoring system can effectively increase the safety (especially in aviation). The article describes analysis connected to possibility of application ASG-EUPOS navigation services in aviation and monitoring systems.
Źródło:
Aparatura Badawcza i Dydaktyczna; 2011, 16, 3; 87-94
2392-1765
Pojawia się w:
Aparatura Badawcza i Dydaktyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analizy wytrzymałościowe podków wykonanych z wykorzystaniem technik odlewniczych
Strength analysis of horseshoes made using casting techniques
Autorzy:
Dudek, P.
Żuczek, R.
Kaźmierczak, M.
Trojanowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/391757.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Odlewnictwa
Tematy:
podkowa
analiza wytrzymałościowa
stopy aluminium
stopy żelaza
horseshoe
strength analysis
aluminum alloys
iron alloys
Opis:
W artykule przedstawiono fragment wyników prac B+R realizowanych w Instytucie Odlewnictwa dotyczących opracowania nowoczesnych tworzyw odlewniczych ze stopów metali żelaznych i nieżelaznych do wykonywania podków o zwiększonej trwałości. Przedstawiono problemy związane z opracowaniem modelu ruchu konia i mechaniki kopyta. Na podstawie ogólnie dostępnych danych przeprowadzono analizy wytrzymałościowe podków wykonanych z wykorzystaniem technik odlewniczych.
The article presents a fragment of results of R&D works carried out at the Foundry Research Institute concerning the development of modern casting materials from ferrous and non-ferrous alloys to make horseshoes with increased durability. Problems related to the development of the horse's movement model and hoof mechanics are presented. On the basis of generally available data, strength analyzes of horseshoes made using castings techniques were carried out.
Źródło:
Prace Instytutu Odlewnictwa; 2018, 58, 3; 171-182
1899-2439
Pojawia się w:
Prace Instytutu Odlewnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Procesy starzenia chemicznego biokomponentów do paliw silnikowych w warunkach przechowywania w zbiornikach magazynowych
Chemical aging of biocomponents for motor fuels during storage in tanks
Autorzy:
Dzięgielewski, W.
Karp, G.
Kaźmierczak, U.
Kulczycki, A.
Okniński, R.
Stefanowicz, P.
Powiązania:
https://bibliotekanauki.pl/articles/251284.pdf
Data publikacji:
2015
Wydawca:
Instytut Naukowo-Wydawniczy TTS
Tematy:
paliwo silnikowe
zbiornik magazynowy
biokomponent
starzenie
motor fuel
storage tank
biocomponent
ageing
Opis:
artykule omówiony został problem starzenia chemicznego biokomponentów do paliw silnikowych. Problem ten stał się ważny dla jakości benzyn i oleju napędowego w sytuacji powszechnego dodawania bioetanolu i FAME. Badaniami objęto bioetanol i FAME przechowywane w różnych warunkach w laboratorium. Zastosowano do oce-ny stopnia zestarzenia biokomponentów standardowe metody badań oraz analizę spektroskopową w zakresie IR i chromatografię gazową. Przedstawiono wyniki badań bioetanolu i FAME przechowywanych przez 1 rok oraz wyniki analiz próbek bioetanolu i FAME przechowywanych w warunkach laboratoryjnych w różnych warunkach. W wyniku przeprowadzonych badań stwierdzono, że proces starzenia bioetanolu przebiega poprzez aldehyd octowy i acetal, a FAME trójetapowo poprzez epitlenki i nadtlenki. Stwierdzono także, że zanieczyszczenia biokomponentów, tj. woda i stałe produkty korozji zbiorników magazynowych przyspieszają procesy starzenia biokomponentów.
The article explains the chemical processes responsible for aging of biocomponents during their storage. This problem is import ant for quality of gasolines and diesel fuel. The study involved bioethanol and FAME stored under different conditions in the laboratory. The standard methods and IR spectroscopy as well as gas chromatography were use for aging processes assessment. The obtained results showed that aging process of bioethanol runs through aldehyde and acetal. Aging of FAME runs through three stages which comprise epioxides and peroxides. It was found that water as well as solid contaminants increase the ratio of aging processes of bioethanol and FAME.
Źródło:
TTS Technika Transportu Szynowego; 2015, 12; 473-477, CD
1232-3829
2543-5728
Pojawia się w:
TTS Technika Transportu Szynowego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The method, based on storage simulator and IR – VIS spectroscopy, for predicting the allowable time of storage of biocomponents for CI engines
Autorzy:
Dzięgielewski, W.
Kaźmierczak, U.
Kulczycki, A.
Okniński, R.
Stefanowicz, P.
Powiązania:
https://bibliotekanauki.pl/articles/242434.pdf
Data publikacji:
2016
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
fuel
fuel aging
oils
lubrication
biocomponents
Opis:
The paper presents the results of investigations concerning a new method used for predicting the allowable time of storage of biocomponents – FAME. The method was based on laboratory research carried out with the use of a storage tank simulator. The aging process was carried out in the conditions increasing the reaction rate – at high temperature. There are several methods/procedures used for predicting the allowable time of storage of fuels and biocomponents – FAME, but all of them are based on tests at the temperature so high that the mechanism of aging process is different than the one observed in storage tanks. It was assumed that the aging process could be divided into two stages: at the first stage, the aging precursors are created and at the second stage, precursors are converted into the fuel aging products. These products lead to changes in fuel properties. The kinetics of precursor creation determines the rate of all reactions, which lead to the final aging products. It was found that the rate of reaction at the first stage of fuel aging can be effectively increased by an increase in temperature and even relatively high temperature does not change the mechanism of the creation of aging precursors. The method that has been worked out makes it possible to control the mechanism of aging process during quick laboratory tests. The products of aging processes were detected with the use of the IR-VIS spectrometry. The allowable time of storage was determined for several FAME samples on the basis of quick laboratory tests. The results of laboratory quick tests were verified by comparing them with the results of the aging process of FAME in storage tanks. On the basis of the test results, the algorithm of allowable time of FAME storage calculation was worked out.
Źródło:
Journal of KONES; 2016, 23, 1; 115-121
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The new stand for aging of biocomponents and biofuels process testing at relatively short time
Autorzy:
Dzięgielewski, W.
Kaźmierczak, U.
Kulczycki, A.
Okniński, R.
Stefanowicz, P.
Powiązania:
https://bibliotekanauki.pl/articles/949517.pdf
Data publikacji:
2016
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
biofuels
biocomponents
ageing process
test bench
method of measuring
Opis:
In the paper, the concept of a model bench for accelerated ageing of bio-components and biofuels was presented. It is used to simulate the ageing process of biofuels and components of vegetable or animal origin, taking place during storage in the storage tanks. The construction of the bench’s essential elements and its equipment were designed and implemented in such a way as to mostly reflect actual storage conditions in large capacity tanks. An additional and unprecedented function of the bench includes the possibility to simulate the product transport conditions. Furthermore, a method of the test, with the use of simultaneously performed traditional tests on the physical and chemical properties monitored in the process of storage was presented. An analysis of the relation between values of the parameters obtained with different methods (on the model bench and under laboratory conditions) was conducted. In addition, their usefulness to assess the impact of logistic processes on the product quality was presented. In the paper, the results of the work executed within the framework of the project “Development of a prototype of the monitoring system the ageing rate and degree of bio-components and biofuels” within the Program Innovative Economy Operational Programme, Measure 1.4. “Support for goal-oriented projects” were used.
Źródło:
Journal of KONES; 2016, 23, 2; 105-112
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania porównawcze działania spłonek elektrycznych w funkcji mocy impulsu pobudzającego
Comparative examinations of electric primers action as a function of initiating pulse power
Autorzy:
Faryński, A.
Kaźmierczak, R.
Kwaśniak, T.
Olejniczak, E.
Urbaniak, R.
Ziółkowski, Z.
Powiązania:
https://bibliotekanauki.pl/articles/235986.pdf
Data publikacji:
2018
Wydawca:
Wojskowy Instytut Techniczny Uzbrojenia
Tematy:
fizyka wybuchu
spłonka elektryczna
zwłoka czasowa
energia wejściowa dysponowana
energia pochłonięta
physics of explosion
electric primer
time delay
disposable input energy
absorbed energy
Opis:
Badano inicjowanie spłonek elektrycznych impulsami o stałej energii i 3 poziomach mocy: P ~1 W, P ~1 kW do P ~1 MW. Porównywano działanie spłonek z mostkiem metalicznym połączonych z zapłonnikiem (SI), pobudzanych ze stałą energią dysponowaną ok. 20 mJ i spłonek z rezystancją rozłożoną w mieszaninie pirotechnicznej (SII), pobudzanych ze stałą energią dysponowaną ok. 200 mJ. Zobrazowano kilkukrotne „podimpulsy” prądowe prowadzące do jednego pobudzenia SII. Średnie opóźnienie zadziałania malało od 8,7 ms przy P ~1 W do 133 µs przy P ~1 MW dla SI oraz od ok. 90 µs przy P ~1 kW do ok. 50 µs przy P ~1 MW dla SII, przy czym od P ~1 kW dla obu rodzajów spłonek praktycznie nie zmieniało się. Przedyskutowano mechanizmy pobudzenia i czynniki wpływające na mierzone opóźnienia. Wyznaczono średnie energie pochłonięte do chwili zadziałania: 5-7 mJ dla SI, ok. 15 mJ dla SII. Oszacowano końcowe ciśnienia: 300-400 bar w korpusach spłonek/zapłonników.
Initiation of electric primers by pulses of constant energy at 3 different levels of power from P ~1 W to P ~1 MW was investigated. Actions of primers with metallic electric bridge (SI) connected to an exploder and initiated by permanent disposable energy of ca. 20 mJ were compared to primers with the resistance distributed within a pyrotechnic mixture (SII) initiated by permanent disposable energy of ca. 200 mJ. A series of current “sub-pulses” at one activation of SII is shown. Average delay of activation was reduced from 8.7 ms at P ~1 W to 133 mikro s at P ~1 MW for SI, and from ca. 90 mikro s at P ~1 kW to ca. 50 mikro s at P ~1 MW for SII, to be in practice unchangeable above P ~1 kW for two types of primers. Mechanisms of initiation and factors influencing the measured delays were discussed. Average energies absorbed to the moment of activation were determined: 5-7 mJ for SI, and ca.15 mJ for SII. Final pressures inside the casing of primers/igniters were estimated on the level of 300-400 bar.
Źródło:
Problemy Techniki Uzbrojenia; 2018, 47, 148; 115-135
1230-3801
Pojawia się w:
Problemy Techniki Uzbrojenia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal Evolution of Magnetic Interactions in Ni Nanowires Embedded in Polycarbonate Membranes by Ferromagnetic Resonance
Autorzy:
Ghaddar, A.
Gieraltowski, J.
Gloaguen, F.
Żuberek, R.
Aleshkevych, P.
Kazmierczak, J.
Slawska-Waniewska, A.
Szymczak, H.
Powiązania:
https://bibliotekanauki.pl/articles/1585046.pdf
Data publikacji:
2009-12
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
62.23.Hj
75.80.+q
75.30.Gw
Opis:
Ni polycrystalline nanowires with diameters of 50, 80, and 100 nm were electrodeposited in cylindrical pores of track-etched polycarbonate membranes. Their magnetic properties were determined as a function of temperature using ferromagnetic resonance and magnetization measurements. At room temperature, the uniaxial anisotropy is equal to the shape anisotropy whereas an additional contribution is evidenced at low temperature. This additional contribution is attributed to magnetoelastic effects induced in the nanowires due to the different thermal expansion constants of Ni and polycarbonate. The analysis of magnetization processes in Ni nanowire arrays evidenced strong dipolar interactions inside the wires due to the domain structure. The coercive field of the nanowires was shown to be nearly a linear function of the temperature and could be accounted for temperature dependence of the uniaxial anisotropy.
Źródło:
Acta Physica Polonica A; 2009, 116, 6; 1039-1043
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pressure waves influence on performance of a pyrotechnically driven device
Autorzy:
Górniak, A.
Kaźmierczak, A.
Włostowski, R.
Ptak, M.
Powiązania:
https://bibliotekanauki.pl/articles/241552.pdf
Data publikacji:
2015
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
pyrotechnically driven devices
shock waves
pyrotechnic gas generator
Opis:
This paper contains an experimental investigation of a movable wall with variable shape response to a shock wave. Here, the shock wave was generated by a pyrotechnic gas generator used in the automotive industry. The test station consists on a pyrotechnic actuator in which the movable wall is expressed as a piston. This pyrotechnic actuator was specially design for such type of an investigation. Its design allows withstanding numerous tests without affecting the accuracy. What was under investigation here was the actuators piston stroke velocity and which, as it appeared, changes with respect to the various shape of the actuators interior as well as a corresponding to the barrier velocity total pressure existing within the expansion chamber of the actuator. The results shown here correspond to the flat surface as well as conical and concave cylinder bottom of the actuator. The conical and flat piston surface is considered as a reference for subsequent investigation because such a design is the most similar to the existing pyrotechnically driven designs. The experimental research proves that the performance of pyrotechnically driven devices is dependent upon the shock wave shaping.
Źródło:
Journal of KONES; 2015, 22, 3; 21-27
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The numerical simulation of the pyrotechnic actuator for the active bumper
Autorzy:
Górniak, A.
Kaźmierczak, A.
Krakowian, K.
Włostowski, R
Błasiński, T.
Powiązania:
https://bibliotekanauki.pl/articles/246526.pdf
Data publikacji:
2012
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
vehicles compatibility
pyrotechnic actuators
shock wave
AUTODYN
Opis:
The paper contains the description and classification of pyrotechnic actuators focusing on the automotive industry applications. This paper also explains the compatibility issues during frontal impact of a passenger car with a large truck. The construction of the pyrotechnic actuators for the "active bumper" is presented here. The processes occurring within the pyrotechnic actuators after ignition of a pyrotechnic propellants have been explained. The investigations are focused on the dependence of a shape of the actuator's combustion chamber and the piston stroke time. It appears that the appropriate design of the combustion chamber can decrease the time required for a piston stroke using this same type of a propellant. This also allows to reduce the amount of propellant when the more rapid stroke is not required. This is because of the characteristics of the detonation waves which are responsible for the piston movement. The visualization of the detonation waves occurring due to ignition of the propellant is crucial for understanding the dependence between the construction of the actuators interior and the piston stroke time. Therefore, the approach of simulating numerically the detonation waves aroused. This simulation was conducted with aid of ANSYS Workbench 13 environment using the AUTODYN module. The numerical tests consists on modelling the actuator without changing the overall dimensions as well as the parameters of the propellant. The only elements modified were piston and the bottom of the cylinder shape.
Źródło:
Journal of KONES; 2012, 19, 3; 141-147
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of Ammonia and Other Pollutants in Air and in the Area of Poultry and Milker Cows Keeping Farms
Oznaczanie amoniaku i innych zanieczyszczeń w powietrzu na terenie ferm hodowli drobiu i krów mlecznych
Autorzy:
Gorzka, Z.
Zaborowski, M.
Kaźmierczak, M.
Żarczyński, A.
Paryjczak, T.
Kędziora, A.
Ciesielski, R.
Pisarek, M.
Powiązania:
https://bibliotekanauki.pl/articles/387972.pdf
Data publikacji:
2012
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
fermy drobiu
oznaczanie amoniaku
obora bydła mlecznego
odory w produkcji rolnej
chicken farms
ammonia determination
cowhouse
odours in agricultural production
Opis:
Polluted air in a big farm of poultry keeping (~18 thousands of chickens) and milker cows (30 animals) in Lodz province was sampled. The aim of the investigation was to determine odour pollutants, especially ammonia, in air and check the possibility of a catalytic method application in their removal. Gas samples were analyzed on the spot of sampling with an application of gases analyser Madur GA-20, as well as in a laboratory with an application of instrumental and spectrophotometric methods. The intensity of odours was estimated using five-stage scale applied by local authorities in Japan for odorous protection of air quality. Within sampling period, poultry keeping in the farm was the source of variable in time ammonia emission ranging from 0.82 to 2.65 mg/m3. Air inside the farm contained carbon dioxide (0–0.3 %) and oxygen (20.5–20.9 %). Carbon monoxide, sulphur dioxide, hydrogen sulphide (> 2.0 mg/m3) and formaldehyde (> 0.25 mg/m3) was not detected. The highest odour intensity inside the building of chicken keeping and at outlets of ventilators was at the third stage in odour scale applied in Japan (3.5), ie, clearly perceptible. However, it decreased significantly with the increase in a distance from the building. Higher ammonia concentrations were determined inside a cowhouse with milker cattle. They ranged from 3.2 to 5.6 mg/m3. Ammonia temporary concentration determined during removal of manure was higher and totalled 15.5 mg/m3. Its highest value (18.8 mg/m3) was determined in gases above slurry in the septic tank.
Wykonano pobory próbek zanieczyszczonego powietrza z dużej fermy drobiu rzeźnego (~18 tys. kurcząt) oraz budynku hodowli bydła mlecznego (30 zwierząt) w województwie łódzkim. Celem badań było wykonanie analiz powietrza na zawartość zanieczyszczeń odorowych, zwłaszcza amoniaku, a w perspektywie zbadanie możliwości zastosowania metody katalitycznego utleniania do ich usuwania. Próbki gazów były analizowane na miejscu pobierania za pomocą automatycznego analizatora gazów Madur GA-20, a także w laboratorium metodami instrumentalnymi i spektrofotometrycznymi. Do oceny intensywności zapachu zastosowano pięciostopniową skalę wykorzystywaną przez władze lokalne w Japonii do ochrony zapachowej jakości powietrza. Hodowla drobiu w badanej fermie była w okresie pobierania źródłem zmiennej w czasie emisji amoniaku w granicach 0,82-2,65 mg/m3. W powietrzu obiektu stwierdzono 0-0,3 % ditlenku węgla i 20,5-20,9 % tlenu, natomiast nie wykryto tlenku węgla, ditlenku siarki, siarkowodoru (> 2,0 mg/m3) ani formaldehydu (> 0,25 mg/m3). Największa intensywność zapachu wewnątrz budynku hodowli kurcząt, a także na wylotach wentylatorów była w trzecim stopniu skali zapachu stosowanej w Japonii (3,5), tj. wyraźna, jednak znacznie obniżała się wraz z oddalaniem się od obiektu. Znaczniejsze były stężenia amoniaku w powietrzu budynku hodowli bydła mlecznego, które mieściły się w zakresie 3,2-5,6 mg/m3. Wyższe było stężenie chwilowe amoniaku podczas usuwania obornika 15,5 mg/m3, a najwyższe w gazach nad gnojowicą w zbiorniku szamba 18,8 mg/m3.
Źródło:
Ecological Chemistry and Engineering. A; 2012, 19, 6; 609-617
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of ammonia and other pollutants in air and in the area of poultry keeping farms
Oznaczanie amoniaku i innych zanieczyszczeń na terenie fermy hodowli drobiu
Autorzy:
Gorzka, Z.
Zaborowski, M.
Kaźmierczak, M.
Żarczyński, A.
Paryjczak, T.
Kędziora, A.
Ciesielski, R.
Pisarek, M.
Powiązania:
https://bibliotekanauki.pl/articles/126036.pdf
Data publikacji:
2011
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
chicken farms
ammonia determination
odours in agricultural production
fermy drobiu
oznaczanie amoniaku
odory w produkcji rolnej
Opis:
Polluted air in a big farm of poultry keeping (~18 thousands of chickens) in Lodz province was sampled. The aim of the investigation was to determine odour pollutants, especially ammonia, in air and check the possibility of a catalytic method application in their removal. Gas samples were analyzed on the spot of sampling with an application of gases analyser Madur GA-20, as well as in a laboratory with an application of instrument and spectrophotometric methods. The intensity of odours was estimated using five-stage scale applied by local authorities in Japan for odorous protection of air quality. Within sampling period, poultry keeping in the farm was the source of variable in time ammonia emission ranging from 0.82 to 2.65 mg/m3. Air inside in farm contained carbon dioxide (0÷0.3%) and oxygen (20.5÷20.9%). Carbon monoxide, sulphur dioxide, hydrogen sulphide (> 2.0 mg/m3) and formaldehyde (> 0.25 mg/m3) was not detected. The highest odour intensity inside the building of chicken keeping and at outlets of ventilators was at the third stage in odour scale applied in Japan (3.5), ie, clearly perceptible. However, it decreased significantly with the increase in a distance from the building.
Próbki zanieczyszczonego powietrza z dużej fermy drobiu rzeźnego (~18 tys. kurcząt) pobrano w województwie łódzkim. Celem badań było wykonanie analiz powietrza na zawartość zanieczyszczeń odorowych, zwłaszcza amoniaku, a w perspektywie zbadanie możliwości zastosowania metody katalitycznego utleniania do ich usuwania. Próbki gazów były analizowane na miejscu pobrania za pomocą automatycznego analizatora gazów Madur GA-20, a także w laboratorium metodami instrumentalnymi i spektrofotometrycznymi. Do oceny intensywności zapachu stosowano pięciostopniową skalę wykorzystywaną przez władze lokalne w Japonii do ochrony zapachowej jakości powietrza. Hodowla drobiu w badanej fermie była w okresie pobrania próbek źródłem zmiennej w czasie emisji amoniaku w granicach 0,82÷2,65 mg/m3. W powietrzu obiektu stwierdzono 0÷0,3% ditlenku węgla i 20,5÷20,9% tlenu, natomiast nie wykryto tlenku węgla, ditlenku siarki, siarkowodoru (> 2,0 mg/m3) ani formaldehydu (> 0,25 mg/m3). Najwyższa intensywność odorowa wewnątrz budynku hodowli kurcząt, a także na wylotach wentylatorów mieściła się w trzecim stopniu skali zapachu stosowanej w Japonii (3,5), tj. wyraźny, jednak znacznie obniżała się wraz z oddalaniem się od obiektu.
Źródło:
Proceedings of ECOpole; 2011, 5, 1; 41-45
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie systemu EGNOS w monitoringu statków powietrznych w aspekcie uruchomienia serwisu Safety-Of-Life
The application of EGNOS system in aircrafts monitoring referred to Safety-of-Life service activation
Autorzy:
Grunwald, G.
Ciećko, A.
Oszczak, S.
Kaźmierczak, R.
Grzegorzewski, M.
Ćwiklak, J.
Powiązania:
https://bibliotekanauki.pl/articles/270415.pdf
Data publikacji:
2011
Wydawca:
Centralny Ośrodek Badawczo-Rozwojowy Aparatury Badawczej i Dydaktycznej, COBRABiD
Tematy:
EGNOS
statki powietrzne
monitoring
aircrafts
Opis:
Artykuł zawiera krótką charakterystykę satelitarnego systemu EGNOS oraz jednego z jego serwisów - Safety- of-Life. Ponadto przedstawiono wyniki badań dokładności systemu EGNOS w oparciu o loty testowe, które odbyły się w Dęblinie i Chełmie w 2010 roku. Do badań wykorzystano satelitarne odbiorniki nawigacyjne Thales MobileMapper oraz geodezyjne Topcon HiperPro i Javad Alpha.
The paper contains short characteristic of satellite system - EGNOS and one of its services - Safety-of-Life. Additionally, are presented the results of EGNOS accuracy research based on experimental flights, which were performed in Dęblin and Chełm in 2010. Satellite navigation receivers - Thales MobileMapper, and geodetic receivers Topcon HiperPro and Javad Alpha were used for experiments.
Źródło:
Aparatura Badawcza i Dydaktyczna; 2011, 16, 3; 133-142
2392-1765
Pojawia się w:
Aparatura Badawcza i Dydaktyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
ESR Spectroscopy of Graphene with Adsorbed NaCl Particles
Autorzy:
Karpierz, E.
Drabińska, A.
Bożek, R.
Kaźmierczak, P.
Wysmołek, A
Kamińska, M
Strupiński, W.
Powiązania:
https://bibliotekanauki.pl/articles/1376214.pdf
Data publikacji:
2014-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
81.05.ue
72.10.Fk
78.67.Wj
72.80.Vp
Opis:
Due to its peculiar properties graphene is a good candidate for sensor materials. Therefore, it is important to study influence of different fluids on graphene layer. The presented studies showed pinning of NaCl microcrystals to graphene surface after immersing graphene in NaCl solution and subsequent careful rinsing with distilled water. The atomic force microscopy images revealed presence of many NaCl-related structures over 100 nm high on graphene surface. The electron spin resonance spectrum for magnetic field perpendicular to the graphene layer consisted of several lines originating from NaCl. The pinning of NaCl microcrystals resulted in increase of electron scattering, as confirmed by the Raman spectroscopy (the increase of intensity of D and D' bands) and weak localization measurement (the decrease of coherence length).
Źródło:
Acta Physica Polonica A; 2014, 126, 5; 1187-1189
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies