Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Janik, G." wg kryterium: Autor


Tytuł:
Supply of water for irrigation of farmlands in the new organizational and legal conditions
Autorzy:
Kuśnierz, M.
Burszta-Adamiak, E.
Janik, G.
Powiązania:
https://bibliotekanauki.pl/articles/101668.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
irrigation
water intake
water law
charges for water services
Opis:
Types of water abstraction sources for irrigation, examples of water supply and water storage in the farmlands as well as advantages and disadvantages of the suggested solutions were analyzed in the article. In addition, the organizational and legal requirements relating to the groundwater and surface water intakes were discussed. From the point of view of the interests of the farmer it is necessary to know the changes that occurred in the fees and administrative responsibilities related to agricultural water intake, introduced by the new Water Law Act since 1 January 2018. The differences between legislation in force and repealed associated with both agricultural water management and environmental protection were demonstrated in the paper.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2018, IV/1; 1057-1070
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zasolenie gleby wyznaczane sensorami FDR działającymi w zmiennej częstotliwości
Soil salinity determined by FDR sensors working in variable frequency
Autorzy:
Wilczek, A.
Skierucha, W.
Janik, G.
Cieśla, J.
Pichler, V.
Powiązania:
https://bibliotekanauki.pl/articles/338288.pdf
Data publikacji:
2012
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
metrologia agrofizyczna
reflektometria częstotliwościowa
sondy reflektometryczne
wilgotność gleby
zasolenie gleby
agro-physical metrology
frequency reflectometry
reflectometric probe
soil moisture
soil salinity
Opis:
Pomiar zasolenia gleby jest dokładnie opisany w literaturze, zwłaszcza przez autorów zajmujących się badaniem parametrów fizykochemicznych gleby w rejonach zagrożonych suszą. Zasolenia gleby, rozumianego jako elektryczna konduktywność ekstraktu roztworu glebowego, nie można zmierzyć w sposób selektywny. Wynika to z faktu, że na pomiar wpływa nie tylko zawartość soli w postaci rozpuszczonych jonów, ale także wilgotność gleby, temperatura i tekstura. Zatem pomiar poziomu zasolenia gleby, szczególnie w warunkach polowych, nadal wymaga prac związanych z metodyką oraz stosowaną aparaturą pomiarową. Idealny miernik zasolenia gleby powinien mierzyć chwilowe wartości wszystkich elementów istotnie wpływających na wynik pomiaru, w tym samym czasie i w tym samym miejscu. Zastosowanie sensorów dielektrycznych, tj. sensorów działających w technice TDR (ang. "time domain reflectometry") (TOPP i in. 1980) i FDR (ang. "frequancy domain reflectometry") (HILHORST, DIRKSEN 1994), umożliwiło integrację czujników wilgotności, przewodnictwa elektrycznego i temperatury gleby w jednym urządzeniu pomiarowym. W artykule przedstawiono elektryczny model sensora FDR, działającego w zakresie częstotliwości od 10-500 MHz, przeznaczonego do pomiaru stanu zasolenia gleby, określonego jako pochodna cząstkowa jej przewodnictwa elektrycznego w stosunku części rzeczywistej zespolonej przenikalności elektrycznej. Jego innowacyjność polega na zastosowaniu szerokiego zakresu częstotliwości pomiaru w celu identyfikacji czynników wpływających na zasolenie gleby, objawiających się w różny sposób przy zmianie częstotliwości sygnału badanego.
Measurement of salinity of the soil is thoroughly described in the literature, especially by authors dealing with the examination of physicochemical parameters of soil in areas threatened by drought. Soil salinity, treated as electrical conductivity of the soil solution, can't be measured in a selective way. This follows from the fact that on the measurement has influence not only the salt content in the form of dissolved ions, but also soil moisture, temperature and texture. Thus, measurement of soil salinity, especially in field conditions require continued work on the methodology and measuring apparatus used. The ideal meter of soil salinity should be measured instantaneous values of all elements of significantly affecting the measurement result, at the same time and same place. The use of dielectric sensors working in the time and frequency domain reflectometry method, opened up new opportunities to integrate measurement sensors of humidity, electrical conductivity and soil temperature in one device. The article presents the electrical model of the FDR sensor designed to measure the salinity of soil as a partial derivative its electrical conductivity to relative real part of complex dielectric permittivity, working in the frequency range from 10-500 MHz. His innovation is to use a wide range of measuring frequency in order to identify factors influencing the soil salinity observed by changing the test frequency.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2012, 12, 2; 341-349
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metoda wyznaczania strefy czułości sensorów TDR
Method for the determination of the sensitivity zone of TDR probe
Autorzy:
Janik, G.
Szpila, M.
Slowinska, J.
Brej, G.
Turkiewicz, M.
Skierucha, W.
Pastuszka, T.
Powiązania:
https://bibliotekanauki.pl/articles/36972.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
pomiary wilgotnosci
sensory TDR
metoda TDR
czulosc testow
gleby
moisture measurement
time domain reflectometry technique
test sensitivity
soil
Opis:
W niniejszej pracy przedstawiono metodę wyznaczania strefy czułości sensorów stosowanych do pomiaru wilgotności objętościowej w ośrodkach porowatych. Analizom poddano czujniki wykorzystujące reflektometrię domenowo czasową (TDR), wyprodukowane w Instytucie Agrofizyki Polskiej Akademii Nauk w Lublinie. Na podstawie przeprowadzonych badań laboratoryjnych stwierdzono, że zasięg strefy czułości sensorów typu laboratoryjnego i polowego jest zależny od zawartości wody w ośrodku, w którym prowadzone są pomiary. W przypadku czujnika laboratoryjnego (LP/ms), gdy oznaczenia prowadzone są w glebie całkowicie suchej, strefę czułości stanowi objętość prostopadłościanu o wymiarach 0,6 cm i 5,8 cm i grubości równej średnicy prętów sondy LP. Natomiast gdy gleba jest nasycona to strefę czułości stanowi walec eliptyczny o wysokości 5,5 cm i promieniach 0,5 cm i 0,8 cm. W przypadku czujnika polowego (FP/mts), gdy pomiary prowadzone są w glebie całkowicie suchej, strefę czułości stanowi walec eliptyczny o wysokości 10,2 cm i promieniach 0,3 cm i 0,4 cm. Natomiast gdy gleba jest nasycona wodą walec o wysokości 11,2 cm i podstawie koła o promieniu 1,7 cm.
The paper presents a method for the determination of the zone of sensitivity of probes used for the measurement of volumetric moisture in porous media. The probes under analysis were TDR (Time-Domain Reflectometry) probes manufactured at the Institute of Agrophysics, Polish Academy of Sciences, Lublin. Based on the laboratory studies performed it was found that the extent of the sensitivity zone of the field- and laboratory-type probes depends on the water content of the medium in which measurements are conducted. In the case of the laboratory probe (LP/ms), when the measurements are conducted in a completely dry soil, the zone of sensitivity of the probe is the volume of a cuboid with dimensions of 0.6 cm by 5.8 cm and a thickness equal to the diameter of the rods of the LP probe. Whereas, when the soil is saturated with water the zone of sensitivity of the probe is an elliptical cylinder with height of 5.5 cm and radii of 0.5 cm and 0.8 cm. In the case of the field probe (FP/mts), when the measurements are conducted in a completely dry soil, the probe sensitivity zone is an elliptical cylinder with height of 10.2 cm and radii of 0.3 cm and 0.4 cm. Whereas, when the soil is saturated with water that zone is a cylinder with height of 11.2 cm and a circular base with a radius of 1.7 cm.
Źródło:
Acta Agrophysica; 2011, 18, 2[193]
1234-4125
Pojawia się w:
Acta Agrophysica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
TDR technique for estimating the intensity of effective non rainfall
Autorzy:
Janik, G
Skierucha, W.
Blas, M.
Sobik, M.
Albert, M.
Dubicki, M.
Zawada, A.
Powiązania:
https://bibliotekanauki.pl/articles/26139.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
time domain reflectometry technique
time-domain reflectometer zob.TDR technique
intensity
non-rainfall water flux
water infiltration
soil
Opis:
The objective of this paper is to present a method for determining diurnal distribution of the intensity of effective non rainfall water flux. It was found that the application of TDR technique for the determination of diurnal dynamics of effective non rainfall water flux requires temperature correction of sensed volumetric moisture contents. Without temperature correction the error of estimated non rainfall water flux can be as much as 26%. In addition, the effect of temperature changes on the soil surface was determined in 0.5, 1, 2, 3, 4, and 5 hours periods. It was found that the intensity of effective non rainfall water flux was determined to the greatest extent by the rate of temperature drop during the period of 3 h preceding the non rainfall water flux determination. The agreement of non rainfall water flux calculated with the method proposed and that obtained by the collector was better for dew than for hoarfrost periods.
Źródło:
International Agrophysics; 2014, 28, 1
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bonitation Analysis of Turf on City Stadium in Wroclaw in the Season of Euro 2012
Autorzy:
Wolski, K.
Janik, G.
Czarnecki, J.
Ziarko, J.
Talar-Krasa, M
Walczak, A.
Biernacik, M.
Dawid, M.
Powiązania:
https://bibliotekanauki.pl/articles/952401.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
sports turf
bonitation analysis
general aspect
colour
sodding
susceptibility to disease
winter survival
Opis:
In 2012–2013, a study was conducted, consisting in a bonitation analysis of turf on the City Stadium which is located in the north-west part of Wroclaw and was a sport arena of the European Championships Euro 2012. The experiment was made with the complete randomisation method for 2 factors, on 5 dates in the growing season. On the turf of the pitch 12 points were selected, and at each of them an evaluation of utility features was performed, in 4 replications, on surface area of 1 m2 . Based on the observation of the condition of the turf, during subsequent analyses it was found how the selection of the mixture of grasses, intensity of use and pratotechnic treatments affect the bonitation quality of sport turfgrass. The results are shown in relation to the whole object, separating each of the features under analysis.
Źródło:
Journal of Ecological Engineering; 2016, 17, 4; 311-320
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The presence and dosimetry of radon and thoron in a historical, underground metalliferous mine
Autorzy:
Kleinschmidt, R.
Watson, D.
Janik, M.
Gillmore, G.
Powiązania:
https://bibliotekanauki.pl/articles/92202.pdf
Data publikacji:
2018
Wydawca:
Główny Instytut Górnictwa
Tematy:
radon
thoron
progeny
mines
dose
NORM
toron
potomstwo
kopalnie
dawka
Opis:
A combination of long term passive, and short term active radon-222, radon-220 and respective progeny measurements were conducted in both traverse and longitudinal axes of a historical metalliferous underground mine in North Queensland, Australia. While the passive monitor results provided average radon and thoron air concentrations over periods of 70-90 days, active measurements over a four day period provided significantly more detail into the dynamics of radon and progeny concentrations in the naturally ventilated mine environment. Passive monitor concentrations for radon and thoron ranged between 60 and 390 Bq m-3 (mean: 140 ±55 Bq m-3) and 140 and 2600 Bq m-3 (mean: 1070 ±510 Bq m-3) respectively, with passive thoron progeny monitors providing a mean concentration of 9 ±5 Bq m-3EEC. Active measurement mean concentrations for radon, thoron, radon progeny and thoron progeny in the centre of the mine drive were 130 ±90 Bq m-3, 300 ±100 Bq m-3, 20 ±20 Bq m-3EEC and 10 ±10 Bq m-3EEC respectively. It was identified that thoron passive detector placement is critical in establishing reliable monitoring data, and is the reason for the discrepancy between the active and passive thoron results in this study. Site specific progeny measurements are required for the accurate estimation of dose to persons entering the mine. Based on short term active measurements and passive thoron progeny monitor results, the dose contribution from thoron and progeny in the mine was observed to contribute up to 80% of the total radon/thoron inhalation dose, and therefore should not be underestimated in monitoring programs under similar conditions.
Źródło:
Journal of Sustainable Mining; 2018, 17, 3; 120-130
2300-1364
2300-3960
Pojawia się w:
Journal of Sustainable Mining
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ekonomiczne aspekty wykonania procedur chirurgicznych metodą otwartą i laparoskopową jako element analizy Health Technology Assessment
Economic aspects of surgery procedures performed in open method and laparoscopy as an element of Health Technology Assessment
Autorzy:
Janik, A.
Bartnicka, J.
Ziętkiewicz, A.
Kowalski, G.
Powiązania:
https://bibliotekanauki.pl/articles/322035.pdf
Data publikacji:
2018
Wydawca:
Politechnika Śląska. Wydawnictwo Politechniki Śląskiej
Tematy:
koszty procedur chirurgicznych
ocena technologii medycznych
analiza ekonomiczna
chirurgia laparoskopowa
chirurgia otwarta
zarządzanie jednostką szpitalną
costs of surgical procedures
health technology assessment
economic analysis
laparoscopic surgery
open surgery
management of the hospital
Opis:
Celem oceny technologii medycznych (ang. Health Technology Assessment – HTA) jest wspieranie świadomego kształtowania polityki i oceny ekonomicznej w zakresie medycyny, a tym samym racjonalnej alokacji zasobów niezbędnych do rozwoju technologii medycznych. Przykładem zmian technologicznych w medycynie jest intensywny rozwój małoinwazyjnych technik chirurgicznych, w tym technik laparoskopowych. Biorąc pod uwagę korzyści uzyskiwane przez pacjenta w wyniku leczenia laparoskopowego, naturalną tendencją powinno być ich zastosowanie w miejsce metod otwartych. Niestety dla osób zarządzających placówkami zdrowia priorytetem jest minimalizacja kosztów wykonywanych procedur medycznych. Z tego względu, celem niniejszego artykułu jest analiza porównawcza kosztów wybranych zabiegów chirurgicznych wykonywanych metodą otwartą i laparoskopową. Uzyskane wyniki są częściowo zaskakujące, gdyż kwestionują przekonanie, że koszt wykonania zabiegów laparoskopowych przekracza koszt identycznych zabiegów wykonywanych metodą otwartą.
The aim of Health Technology Assessment is to support activities intended to form politics as well as economic analysis in medicine and hence rational allocation of resources which are necessary for developing medical technologies. An example of technological changes in medicine is an intensive development of minimally invasive surgical techniques including laparoscopic techniques. Taking into account the great benefits of laparoscopic treatment for patient the natural tendency should be the change of open surgeries to minimal invasive procedures. However the problem of conflicts costs-benefits is indicated by health managers, for whom the procedures’ costs are treated as a priority. Taking this as a background for considerations, there was formulated the research objective that is a comparative analysis of selected surgical procedures performed in open method and laparoscopy. The outcomes are partly surprising and questioned the hypothetical rule that the cost of performing laparoscopic procedures exceed the cost of identical procedures, but executed with open method.
Źródło:
Zeszyty Naukowe. Organizacja i Zarządzanie / Politechnika Śląska; 2018, 115; 75-90
1641-3466
Pojawia się w:
Zeszyty Naukowe. Organizacja i Zarządzanie / Politechnika Śląska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Technika SFAT w dynamicznej radioterapii nowotworów okolicy głowy i szyi: weryfikacja dozymetryczna planów leczenia
Autorzy:
Janik, M.
Klimas, A.
Żygliński, G.
Hutnik, M.
Powiązania:
https://bibliotekanauki.pl/articles/112448.pdf
Data publikacji:
2018
Wydawca:
Indygo Zahir Media
Tematy:
dozymetria
radioterapia
onkologia
nowotwór szyi
nowotwór głowy
Opis:
W Polsce około 5,5-6,2% wszystkich diagnozowanych nowotworów stanowią nowotwory okolicy głowy i szyi [1]. Jednym ze sposobów leczenia w takich przypadkach jest radioterapia. Wiele schematów leczenia takich zmian wymaga elektywnego napromienienia układu chłonnego szyi [2]. Wiąże się to z podaniem wysokiej dawki (zazwyczaj 50 Gy, frakcjonowane 2 Gy na dzień) na obszar, w którym zawiera się wiele narządów, których uszkodzenie może znacząco pogorszyć komfort życia pacjenta. Organy takie nazywamy organami krytycznymi OAR (Organ At Risk) i w tej okolicy zaliczamy do nich m.in.: krtań, tarczycę, ślinianki, rdzeń kręgowy i inne [3]. Dawkę zaplanowaną należy podać na konkretny obszar z jednoczesną ochroną tych narządów. Zadaniem fizyka medycznego jest stworzenie planu leczenia, który będzie cechował się bardzo wysokim dopasowaniem kształtu izodoz do obszaru zaplanowanego PTV (Planning Target Volume) [4], czyli wysoką konformalnością. Należy również pamiętać, że każdy plan leczenia przed realizacją musi zostać dozymetrycznie zweryfikowany. Ważne jest więc, by stworzony plan był łatwo weryfikowalny. W pracy [5] pokazano, że technika SFAT (Split Fields Arc Therapy) pomaga uzyskać plany o wysokiej konformalności z jednoczesnym osiągnięciem bardzo dobrych parametrów planu radioterapeutycznego V95 i V101.5. Metoda ta zwiększa także możliwość ochrony OAR. Technika SFAT zakłada stworzenie planu RapidArc, który podczas jednego pełnego obrotu gantry wykorzystuje pół pola napromieniania. Realizowane jest to dzięki zamknięciu jednej ze szczęk kolimatora. Pozwala to optymalizatorowi dowolnie modulować rozmiar pola w trzech pozostałych kierunkach. Taka implementacja oznacza, że w osi kolimatora powstaje obszar półcienia. Nasuwa się pytanie: czy może to sprawiać problemy podczas weryfikacji dozymetrycznej? W niniejszej pracy podjęto próbę oceny, czy taki sposób tworzenia planów radioterapeutycznych niesie ze sobą istotne różnice podczas procesu weryfikacji dozymetrycznej.
Źródło:
Inżynier i Fizyk Medyczny; 2018, 7, 3; 199-202
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optical Characterization of MBE-Grown Cd$\text{}_{1-x}$Mn$\text{}_{x}$Te Layers by Raman Spectroscopy
Autorzy:
Szuszkiewicz, W.
Dynowska, E.
Janik, E.
Karczewski, G.
Wojtowicz, T.
Kossut, J.
Jouanne, M.
Powiązania:
https://bibliotekanauki.pl/articles/1945228.pdf
Data publikacji:
1996-03
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
63.20.-e
75.50.Pp
78.30.-j
Opis:
In this paper we discuss a possibility of an optical characterization of thin semiconductor epilayers by Raman scattering measurements. As an example zinc blende Cd$\text{}_{1-x}$Mn$\text{}_{x}$Te epilayers (0.66 ≤ x ≤ 1.0) have been grown by molecular beam epitaxy method and investigated by Raman scattering and X-ray diffraction. Information resulting from both methods is compared and discussed.
Źródło:
Acta Physica Polonica A; 1996, 89, 3; 335-340
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Raman Scattering by Phonons and Magnons in MBE-Grown Cd$\text{}_{1-x}$Mn$\text{}_{x}$Te Layers
Autorzy:
Szuszkiewicz, W.
Jouanne, M.
Dynowska, E.
Janik, E.
Karczewskl, G.
Wojtowicz, T.
Kossut, J.
Powiązania:
https://bibliotekanauki.pl/articles/1934042.pdf
Data publikacji:
1995-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
75.30.Ds
63.20.-e
78.30.Fs
Opis:
Collective excitations have been analyzed for Cd$\text{}_{1-x}$Mn$\text{}_{x}$Te epilayers (0.66 ≤ x ≤ 1) by the Raman scattering studies performed at temperatures from 7 K to 295 K. Apart from the lattice optical modes magnetic excitations (magnons) were observed at sufficiently low temperatures.
Źródło:
Acta Physica Polonica A; 1995, 88, 5; 941-944
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Luminescence Decay in Deep Quantum Wells CdTe/Cd_{0.5}Mn_{0.5}Te at Room Temperature
Autorzy:
Kowalczyk, L.
Fancey, S.
Buller, G.
Massa, J.
Kutrowski, M.
Janik, E.
Karczewski, G.
Wojtowicz, T.
Zakrzewski, A.
Kossut, J.
Powiązania:
https://bibliotekanauki.pl/articles/1876908.pdf
Data publikacji:
1995-02
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
78.66.Hf
78.47.+p
78.55.Et
Opis:
Time-resolved photoluminescence was used to study exciton recombination in deep CdTe/Cd_{0.5}Mn_{0.5}Te single quantum well. The width of the investigated well was 100 A. The study was performed at room temperature. The lifetime of the exciton determined in this work has a value comparable to that observed in shallow CdTe/Cd_{0.85}Mn_{0.15}Te quantum wells. A strong enhancement of the photoluminescence decay time with increasing intensity of the exciting laser beam is observed which is indicative of saturation of the non-radiative recombination centers.
Źródło:
Acta Physica Polonica A; 1995, 87, 2; 508-513
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies