Wyświetlanie 1-10 z 10
Tytuł:
Luminescence Decay Kinetics in GaN Studied by Frequency Domain Measurements
Autorzy:
Mickevičius, J.
Vitta, P.
Tamulaitis, G.
Žukauskas, A.
Shur, M.
Zhang, J.
Yang, J.
Gaska, R.
Powiązania:
https://bibliotekanauki.pl/articles/1813195.pdf
Data publikacji:
2008-03
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
72.20.Jv
78.55.Cr
Opis:
Carrier dynamics in high-quality GaN epilayer was investigated at two extreme excitation levels. Carrier lifetime under high excitation conditions was estimated by using light-induced transient grating technique. Measurements at extremely low excitation power density were performed by using frequency-domain fluorescence lifetime technique. The study was performed in a wide temperature range from 8 to 300 K. The results revealed the influence of donor-acceptor pair recombination and carrier trapping processes.
Źródło:
Acta Physica Polonica A; 2008, 113, 3; 833-837
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Błąd dokumentowania geologiczno-inżynierskiego i jego skutki dla budowy stoku narciarskiego w Przemyślu
The error in geological-engineering reporting and its consequence for the construction of the ski slope in Przemyśl
Autorzy:
Gąska, P.
Powiązania:
https://bibliotekanauki.pl/articles/2063068.pdf
Data publikacji:
2011
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
budowa stoku narciarskiego
osuwisko
spełzywanie
drenaż
posadowienie
construction of a ski slope
landslide
creeping
drainage
foundation
Opis:
W artykule przedstawiono skutki błędu dokumentowania geologiczno-inżynierskiego, powstałego na etapie projektu budowy stoku narciarskiego w Przemyślu. Opisano proces weryfikacji dokumentacji geologiczno-inżynierskiej oraz zmianę sposobu fundamentowania obiektów inżynierskich, projektowanych do zabudowy stoku narciarskiego.
Results of errors of the engineering-geological reporting, arisen at the building plan stage, for the sky slope in Przemyśl have been presented in this paper as well as verification of engineering-geological reports and change of foundations method of engineering objects designed to develop the ski slope.
Źródło:
Biuletyn Państwowego Instytutu Geologicznego; 2011, 446 (1); 49--52
0867-6143
Pojawia się w:
Biuletyn Państwowego Instytutu Geologicznego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza numeryczna konstrukcji systemu rozsączającego wody opadowe
Numerical analysis of construction of drainage system for precipitation waters
Autorzy:
Gąska, P.
Powiązania:
https://bibliotekanauki.pl/articles/390620.pdf
Data publikacji:
2013
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
system rozsączający
odciążenie gruntu
model numeryczny
geosiatka
ściana żelbetowa
stateczność
drainage system
strain relief
numerical model
geogrid
reinforced concrete wall
stability
Opis:
Dostępność nowoczesnych narzędzi, pozwalających na zaawansowane analizy geotechniczne, skłoniła autora niniejszej publikacji do zweryfikowania przyjętych uprzednio, po części intuicyjnych, rozwiązań technicznych konstrukcji systemu rozsączającego wody opadowe, polegającego na zastosowaniu elementów odciążających w postaci ścian żelbetowych oraz poziomych geosiatek. Metodą elementów skończonych w modelu numerycznym otrzymano ilościową analizę rozkładu naprężeń w ośrodku gruntowym otaczającym system rozsączania wód opadowych, która potwierdza intuicyjne, jakościowe, założenia projektu technicznego. Dzięki zastosowaniu żelbetowych ścian przenoszących parcie boczne gruntu na grunt powyżej jak i poniżej systemu rozsączającego uzyskano dwukrotne zmniejszenie poziomych składowych naprężeń ośrodka gruntowego w strefie pomiędzy żelbetowymi ścianami a systemem rozsączającym. Zastosowanie dwóch warstw geosiatki powyżej systemu rozsączającego umożliwiło odciążenie systemu rozsączania (w środkowej, najbardziej wrażliwej strefie) w kierunku pionowym o około 75%.
Progressive implements which make possible advanced geotechnical analysis, induced the author to verify previously accepted engineering solutions of construction of rain waters drainage system with the use of reinforced concrete walls and horizontal geogrids. The quantitative analysis of stress distribution in ground medium around the drainage system was performed in numerical model with the use of finite element method . This analysis confirmed previous – intuitive and qualitative - assumptions of the technical design. The application of reinforced concrete walls, transmission of ground lateral pressure to the soil below and the above drainage system, result in twofold reduction of horizontal components of ground stresses in area between reinforced walls and the drainage. The usage of two layers of geogrid over the drainage system made possible strain relief of this system (in the middle, the most sensitive zone) in vertical direction of about 75%.
Źródło:
Budownictwo i Architektura; 2013, 12, 3; 91-96
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identification and correction of coordinate measuring machine geometrical errors using lasertracer systems
Autorzy:
Gąska, A.
Gruza, M.
Gąska, P.
Karpiuk, M.
Sładek, J.
Powiązania:
https://bibliotekanauki.pl/articles/103146.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
LaserTracer
coordinate measuring machine
geometrical error
Opis:
LaserTracer (LT) systems are the most sophisticated and accurate laser tracking devices. They are mainly used for correction of geometrical errors of machine tools and coordinate measuring machines. This process is about four times faster than standard methods based on usage of laser interferometers. The methodology of LaserTracer usage to correction of geometrical errors, including presentation of this system, multilateration method and software that was used are described in details in this paper.
Źródło:
Advances in Science and Technology. Research Journal; 2013, 7, 20; 17-22
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of z-axis kinematics influence on measurement result
Autorzy:
Gruza, M.
Harmatys, W
Gąska, P.
Gąska, A.
Sładek, J.
Powiązania:
https://bibliotekanauki.pl/articles/103398.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
CMM accuracy
CMM kinematics
Opis:
CMMs accuracy depend on a number of factors. In spite of using various methods for CMM correction, the differences can be observed in the metrological capability be¬tween the areas in the measuring volume of CMM. Authors attempted to estimate the impact of one of potential CMM accuracy influencing factors, a CMM Z-axis position during measurement, on measurement result. This article presents performed experi¬ments and obtained results.
Źródło:
Advances in Science and Technology. Research Journal; 2015, 9, 26; 109--112
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of temperature impact on cmm residual kinematic errors distribution
Autorzy:
Harmatys, W
Gąska, P.
Gąska, A
Gruza, M.
Sładek, J.
Powiązania:
https://bibliotekanauki.pl/articles/102879.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
residual errors
CMM correction
Opis:
In case of coordinate machines that use CAA correction matrix, the issue of kine¬matic errors analysis may be based on the determination of residual error distribu¬tion. Temperature changes have an impact on CMM kinematic structure, which may cause the differences in the map of residual errors. As for today, the residual errors were analysed only for the reference temperature. No research was undertaken on the residual errors changes depending on the temperature variations. This paper presents the experiment aimed at residual errors analysis and resulting errors distributions for different temperatures.
Źródło:
Advances in Science and Technology. Research Journal; 2015, 9, 26; 113--117
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of measured workpiece’s form errors influence on the accuracy of probe heads used on five-axis measuring systems
Autorzy:
Harmatys, W.
Gąska, A.
Gruza, M.
Gąska, P.
Sładek, J.
Powiązania:
https://bibliotekanauki.pl/articles/102182.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
articulating probe head
five-axis system
accuracy
CMM
Opis:
The five-axis measuring systems are one of the most modern inventions in coordinate measuring technique. They are capable of performing measurements using only the rotary pairs present in their kinematic structure. This possibility is very useful because it may cause significant reduction of total measurement time and costs. However, it was noted that high values of measured workpiece’s form errors may cause significant reduction of the accuracy of a five-axis measuring system. The investigation on the relation between these two parameters was conducted in this paper and possible reasons of decrease in measurement accuracy was discussed on the example of measurements of workpieces with form errors ranging from 0,5 to 1,7 millimetre.
Źródło:
Advances in Science and Technology. Research Journal; 2017, 11, 4; 305-310
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of the impact of probe head hysteresis on the accuracy of five-axis coordinate measuring systems
Autorzy:
Gąska, P.
Gruza, M.
Gąska, A.
Harmatys, W.
Sładek, J.
Powiązania:
https://bibliotekanauki.pl/articles/102633.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
articulating probe head
hysteresis
accuracy
CMM
Opis:
One of the factors affecting the accuracy of Coordinate Measuring Systems is hysteresis of a probe head. It is important especially in case of touch trigger probes and should be taken into account during the determination of probing strategy. In this article, the authors try to assess how this phenomenon affects the accuracy of five axis coordinate systems which utilize articulating probe head. Such systems allow to measure point coordinates using rotary movements of the head what introduces changes to the probing process. The experiments presented in this paper are based on multiple measurements of the reference elements such as gauge blocks and standard ring.
Źródło:
Advances in Science and Technology. Research Journal; 2017, 11, 3; 277-282
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of influence of the parameters connected with the stabilization of the position on the 5-axis manipulators’ operation accuracy
Autorzy:
Gaska, A.
Harmatys, W.
Gruza, M.
Gaska, P.
Sladek, J.
Powiązania:
https://bibliotekanauki.pl/articles/100183.pdf
Data publikacji:
2018
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
pose accuracy
5-axis system
LaserTracer
CMM
Opis:
The 5-axis systems, especially those that use in their kinematic chain both prismatic joints and revolute kinematic pairs are gaining popularity in many scientific disciplines with manufacturing, metrology and robotics at the forefront. This is therefore important to undertake research aiming in identification of sources of inaccuracies in their functioning and investigation on possibility of eliminating or compensating them. A significant impact on 5-axis kinematic structures accuracy may be assigned to parameters associated with the stabilization of the machine position and angular position, such as position stabilization time, position overshoot and drift of positioning accuracy. These parameters are well described in ISO 9283 standard related to performance criteria and test methods for industrial robots. The methodology presented in this standard is adapted for testing the impact of mentioned parameters for functioning of 5-axis kinematic structures other than industrial robots, which mainly include five-axis coordinate measuring systems and machine tools. A series of experiments performed on five-axis coordinate measuring system is presented in this paper, their results are assessed in a quantitative manner and basing on them a general algorithm for assessing the significance of impact of position stabilization parameters on functioning of the manipulator is proposed.
Źródło:
Journal of Machine Engineering; 2018, 18, 2; 54-63
1895-7595
2391-8071
Pojawia się w:
Journal of Machine Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Method for predicting the accuracy of rotational elements measurements using the five-axis coordinate measuring system
Autorzy:
Gaska, P.
Gruza, M.
Harmatys, W.
Gaska, A.
Sladek, J.
Powiązania:
https://bibliotekanauki.pl/articles/99483.pdf
Data publikacji:
2018
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
accuracy
coordinate measuring systems
probing systems
Opis:
The measurements of solids of revolution are one of the most common task in industrial practice. Therefore it is not surprising, that new solutions dedicated to improve accuracy and acceleration of measurements of rotational components are emerging. In this group, the new generation of articulating probing systems (with ability of continuous indexation) is worth mentioning. These probing devices combined with standard CMM forms the five-axis coordinate system. Such solution results in measurements acceleration and also improve measurement repeatability. Studies on this type of probing systems proved that their accuracy depends strongly on the angular orientation of probing system used during measurement. Therefore authors developed model that allows simulation of probing system errors for any orientation. This article describes an attempt to use the model to find the configuration of the probing system that would provide the highest accuracy for rotational elements measurements. The simulation results are compared to the real measurements of standard elements performed on five axis measuring system. Described prediction method could have a beneficial effect on improving the accuracy of measurements and, as a result, on reducing production costs by minimizing the risk of erroneous decision on the conformity of products with their geometric specifications.
Źródło:
Journal of Machine Engineering; 2018, 18, 3; 78-86
1895-7595
2391-8071
Pojawia się w:
Journal of Machine Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-10 z 10

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies