Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Flis, Mateusz" wg kryterium: Autor


Wyświetlanie 1-4 z 4
Tytuł:
Contactless turnouts’ heating for energy consumption optimization
Autorzy:
Flis, Mateusz
Powiązania:
https://bibliotekanauki.pl/articles/141430.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
electric turnouts heating ETH
optimization of ETH system
temperature field
simulations
Opis:
An electric turnout heating (ETH) system is an essential technical and economic issue. Uninterrupted operation of the turnouts is crucial to maintaining railway transport safety. The classic heating system is characterized by high energy consumption. The usage of it is extremely expensive, so the need to optimize the current system becomes more and more critical. At the same time, the progress in the contactless heating method has become a promising alternative. The paper presents the results of tests performed for electric turnout heating systems for two types of heaters. In the first place, the analysis of heat distribution was performed using the ANSYS Fluent v.16. The temperature fields in the turnout models filled with a model of semi-melting snow were analyzed. Thanks to cooperation with the Railway Institute in Warsaw the second stage of the research was possible to be completed. In this part, the models were implemented in the real world using the 49E1 railway turnout. The numerical solutions were validated by the experiments. The verification showed a high level of agreement among the results. The obtained results indicate the need for further tests of heating systems, to validate an optimal method of turnout heating. It was found that in the classic ETH, the working space area consumes a tremendous amount of energy. To ensure a higher efficiency of the heating process, the contactless heater is proposed as an alternative.
Źródło:
Archives of Electrical Engineering; 2020, 69, 1; 133-145
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Eksperymentalna ocena bezstykowej metody ogrzewania w systemie elektrycznego ogrzewania rozjazdów kolejowych
Autorzy:
Brodowski, Dariusz
Flis, Mateusz
Powiązania:
https://bibliotekanauki.pl/articles/2131838.pdf
Data publikacji:
2022
Wydawca:
Instytut Kolejnictwa
Tematy:
elektryczne ogrzewanie rozjazdów
optymalizacja
bezstykowe elektryczne ogrzewanie rozjazdów
electric turnouts heating ETH
optimization of ETH system
contactless electric turnout heating
Opis:
W warunkach zimowych rozjazdy kolejowe są elementem infrastruktury kolejowej, który jest szczególnie narażony na działanie warunków atmosferycznych, takich jak opady i nawiewanie śniegu, opady marznącego deszczu oraz niskie temperatury. Aby zachować ich pełną sprawność, podczas niekorzystnych warunków atmosferycznych stosuje się systemy ogrzewania rozjazdów. Podstawowym systemem używanym od dziesięcioleci na kolejach europejskich jest elektryczne ogrzewanie rozjazdów. System ten wykorzystuje grzejniki oporowe, charakteryzuje się dużym zużyciem energii i niską wydajnością. W wielu krajach europejskich, zarządcy infrastruktury kolejowej poszukują nowych rozwiązań w zakresie elektrycznego ogrzewania rozjazdów. W niniejszym artykule przedstawiono eksperymentalną ocenę nowej koncepcji elektrycznego ogrzewania rozjazdów. Nowa metodologia wykorzystuje grzejniki bezstykowe zamiast tradycyjnych i opiera się na innowacyjnym sposobie wykorzystania rozkładu ciepła. Za referencyjny obiekt dla grzejnika bezstykowego przyjęto standardowy system elektrycznego ogrzewania rozjazdu. Badania eksperymentalne w warunkach rzeczywistych przeprowadzono w rozjazdach eksploatowanych w sieci PKP. Badania przeprowadzono w różnych warunkach pogodowych. W czasie badań wykonano pomiary termowizyjne, pomiary czujnikami termoparowymi oraz obserwacje szybkości wytapiania. W każdym przypadku przeprowadzono badania porównawcze. Wyniki zostały zebrane, przeanalizowane, podsumowane i przedstawione w artykule.
Źródło:
Problemy Kolejnictwa; 2022, 194; 9--15
0552-2145
2544-9451
Pojawia się w:
Problemy Kolejnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energy efficiency analysis of railway turnout heating system with a melting snow model heated by classic and contactless heating method
Autorzy:
Flis, Mateusz
Powiązania:
https://bibliotekanauki.pl/articles/140565.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
electrical heating
enthalpy method
experimental research
melting process
railway turnouts
thermal field
heat distribution
Opis:
Maintaining railway turnout operability is crucial for ensuring railway transport safety. Electric heating of railway turnouts is a significant technical and economic issue. The classical heating is characterised by high power consumption. For this reason, research is needed to optimise the current system. This paper presents results of a numerical analysis and of experimental researches. The numerical analysis was carried out using the ANSYS software. There was conducted a numerical comparative analysis of energy loss during heating performed using two different heaters. Including the classical method and a heater thermally insulated from a rail. In the first step, heating of a working space filled with a substitute snow model was considered. The snow-covered surface area was held within the working space of the turnout. It was assumed that the snow substitute material had thermal properties approximately the same as real light snow. It was also assumed that the material is in the solid state which would not undergo a phase change. In the next step, a real snow model that included the phase change process was taken into account. The energy efficiency and heat distribution in the turnout have been analysed and compared. The experimental researches were carried out in a physical model. The results showed that the use of a contactless heater results in creating a larger area over which emitted heat affected snow in the working space. Consequently, more snow was melted around the contactless heater than the classic one. This experimental observation supported the results of the numerical analyses presented previously.
Źródło:
Archives of Electrical Engineering; 2019, 68, 3; 511-520
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental Verification of Contactless Heating Method in Railway Turnouts Heating System
Autorzy:
Brodowski, Dariusz
Flis, Mateusz
Powiązania:
https://bibliotekanauki.pl/articles/2131840.pdf
Data publikacji:
2022
Wydawca:
Instytut Kolejnictwa
Tematy:
electric turnouts heating ETH
optimization of ETH system
contactless electric turnout heating
elektryczne ogrzewanie rozjazdów
optymalizacja
bezstykowe elektryczne ogrzewanie rozjazdów
Opis:
In winter conditions, railroad turnouts are an element of railway infrastructure that is particularly vulnerable to weather conditions such as snowfall, blowing of freezing rainfall, low temperatures. To maintain them in full operability during un-favorable weather conditions turnouts heating systems are used. The basic system used for decades on European railways is the electric heating of turnouts (ETH). This system uses resistance heaters, is characterized by high energy consumption and low efficiency. Railway authorities, in many European countries, look for new solutions in the field of electric turnouts heating. In this paper experimental verification of a new ETH concept is presented. The new methodology uses contactless heaters instead of the classic ones and is based on an innovative way of heat distribution. As a reference object for the con-tactless heater, the classic ETH was used. Experimental research in real conditions were carried out at turnouts exploited in the Polish State Railways (PKP) network. The research was carried out in various weather conditions. As a part of the test, thermo-vision measurements were done, as well as measurements by thermo-couples and a melting rate was observed. In each case, comparative tests were carried out. The results were gathered, analyzed, concluded and presented in the paper.
Źródło:
Problemy Kolejnictwa; 2022, 194; 73--79
0552-2145
2544-9451
Pojawia się w:
Problemy Kolejnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies