Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Dudziak, E." wg kryterium: Autor


Wyświetlanie 1-59 z 59
Tytuł:
Magnetooptical Studies of Quasi-Two-Dimensional Electron Layer on HgCdMnTe
Autorzy:
Dudziak, E.
Bożym, J.
Pruchnik, D.
Powiązania:
https://bibliotekanauki.pl/articles/1877146.pdf
Data publikacji:
1995-02
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
73.30.+y
78.20.Ls
72.40.+w
Opis:
Photovoltaic magneto-spectroscopy was used for the first time as the interband probe in the study of the 2D electron gas on narrow-gap HgCdMnTe semiconductor. The strong circular dichroism was found which agrees with the phenomenological description of the optical properties of the 2D electron systems in quantized Hall regime. The model of coupled intersubband resonances and interband transitions was proposed as a qualitative explanation.
Źródło:
Acta Physica Polonica A; 1995, 87, 2; 563-566
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of Phonons in HgCdMnTe Using Far-Infrared Reflectivity
Autorzy:
Dudziak, E.
Bożym, J.
Pruchnik, D.
Baran, J.
Powiązania:
https://bibliotekanauki.pl/articles/1929684.pdf
Data publikacji:
1993-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
78.30.Fs
71.45.Gm
Opis:
The first reflectivity spectra of Hg$\text{}_{1-x-y}$Cd$\text{}_{x}$Mn$\text{}_{y}$Te with 0.03 < x < 0.1 and 0 < y < 0.05 were measured in the spectral region 700-30 cm$\text{}^{-1}$ at 300 K and 90 K. The quaternary alloys measured show three mode behaviour. The experimental results are interpreted by using a classical dynamic dielectric function model.
Źródło:
Acta Physica Polonica A; 1993, 84, 3; 595-598
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nonlinear Temperature Dependence of the Band Gap in Hg$\text{}_{1-x-y}$Cd$\text{}_{x}$Mn$\text{}_{y}$Te and Hg$\text{}_{1-x}$Cd$\text{}_{x}$Te Alloys
Autorzy:
Dudziak, E.
Jędral, L. Z.
Bożym, J.
Brzeziński, J.
Powiązania:
https://bibliotekanauki.pl/articles/1886577.pdf
Data publikacji:
1991-02
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
71.25.Tn
65.70.+y
Opis:
The temperature dependence of the band gap for HgCdTe and HgCdMnTe has been experimentally investigated in the temperature range of 7-250 K. The distinct nonlinear dependence has been observed in the low temperature range. It was shown that the lattice dilatation contribution calculated for HgCdTe is a significant part (about 30%) of the total temperature shift of the energy gap.
Źródło:
Acta Physica Polonica A; 1991, 79, 2-3; 291-294
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Faraday Rotation in Multiple Quantum Wells of GaAs/AlGaAs
Autorzy:
Dudziak, E.
Bożym, J.
Pruchnik, D.
Wasilewski, Z. R.
Powiązania:
https://bibliotekanauki.pl/articles/1952529.pdf
Data publikacji:
1996-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
78.20.Ls
73.20.Dx
78.66.Fd
Opis:
We report on the results of first measurements of the Faraday rotation of modulated n-doped multiple quantum wells of GaAs/Al$\text{}_{x}$Ga$\text{}_{1-x}$As (x = 0.312). The measurements have been performed in the magnetic fields up to 13 T at the temperature of 2 K, in the spectral region of interband transitions. A rich structure of magneto-excitons has been found in the measured spectra. Faraday rotation (phase) measurements are proposed as an alternative method to photoluminescence excitation for investigations of magneto-excitons in quantum wells. The dependence of the measured Faraday rotation on magnetic field and hypothetical connections with quantum Hall effect are also discussed.
Źródło:
Acta Physica Polonica A; 1996, 90, 5; 1022-1026
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Large Filling-Factor-Dependent Spin Splitting in Magnetooptic Kerr Effect in GaAs/AlGaAs Multiple Quantum Wells
Autorzy:
Dudziak, E.
Bozym, J.
Pruchnik, D.
Wasilewski, Z. R.
Powiązania:
https://bibliotekanauki.pl/articles/1969050.pdf
Data publikacji:
1998-08
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
78.20.Ls
73.20.Dx
78.66.Fd
Opis:
Magnetooptic Kerr effect in GaAs/Al$\text{}_{0.312}$Ga$\text{}_{0.688}$As multiple quantum wells was investigated in the integer quantum Hall regime. The measurements have been performed in magnetic fields up to 14.5 T, at the temperature of 1.8 K. Experimental data indicate the discontinuous behavior of the magnetooptic Kerr effect spectrum as a function of the filling factor. For odd filling factor values ν=3 and 5 we observe the large spin splitting. The effects cannot be explained in the one-particle model.
Źródło:
Acta Physica Polonica A; 1998, 94, 2; 291-296
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Magnetooptical Studies of CdTe-Rich Epitaxial Layers
Autorzy:
Dudziak, E.
Bożym, J.
Pruchnik, D.
Jędral, L. Z.
Powiązania:
https://bibliotekanauki.pl/articles/1890795.pdf
Data publikacji:
1991-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
71.25.Tn
72.40.+w
78.20.Ls
Opis:
The first magnetooptical studies comprising magnetoreflection, magnetoabsorption and Faraday rotation of CdTe-rich Hg$\text{}_{1-x-y}$Cd$\text{}_{x}$Mn$\text{}_{y}$Te are reported. The drastic disappearing of excitonic structure, for already very small Hg content, has been observed. The exchange parameters close to those for CdMnTe have been found.
Źródło:
Acta Physica Polonica A; 1991, 80, 3; 325-328
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ wybranych mikrozanieczyszczeń organicznych na ekosystemy wodne
The influence of selected organic micropollutants on water ecosystems
Autorzy:
Kudlek, E.
Dudziak, M.
Powiązania:
https://bibliotekanauki.pl/articles/400357.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
mikrozanieczyszczenia organiczne
toksyczność
środowisko wodne
organic micropollutants
toxicity
water environment
Opis:
W pracy dokonano przeglądu literatury pod kątem oddziaływania wybranych mikrozanieczyszczeń z grupy związków farmaceutycznych, konserwantów żywności, pestycydów oraz organicznych filtrów UV na różne gatunki roślin oraz zwierząt zasiedlających ekosystemy wodne. W badaniach własnych oceniono wpływ stężenia mikrozanieczyszczeń obecnych w środowisku wodnym na wywoływany efekt toksykologiczny u wybranych organizmów wskaźnikowych. Badania prowadzono przy użyciu bakterii słonowodnych z rodzaju Aliivibrio fischer, skorupiaków słodkowodnych Daphnia magna oraz słonowodnych Artemia fanciscana, jak również roślin naczyniowych Lemna minor. Wykazano, że organizmy testowe cechują się odmienną czułością na obecność mikrozanieczyszczeń. W przypadku wszystkich stosowanych testów wraz ze wzrostem stężenia związku obserwowano wzrost odpowiedzi organizmów wskaźnikowych świadczący o wzroście toksycznego oddziaływania mikrozanieczyszczenia. Najwyższą toksycznością zarówno względem bakterii, skorupiaków jak i roślin naczyniowych charakteryzował się roztwór benzofenonu-3 o stężeniu 5 mg/dm3.
The paper presents a literature review in terms of the impact of selected micropollutants from the group of pharmaceutical compounds, food preservatives, pesticides and organic UV flters on various plants and animals species, which inhabit the water ecosystems. During own studies the impact of concentrations of micropollutants in the water environment on selected indicator organisms was evaluated. The study was conducted using saltwater Aliivibrio fischer bacteria, freshwater Daphnia magna and saltwater Artemia fanciscana crustaceans, as well as vascular plants Lemna minor. It was shown that the test organisms are characterized by a different sensitivity for the presence of micropollutants. For all applied tests an increase in the response of indicator organisms with the increasing compound concentration was observed. It demonstrates the growing toxic impact of micropollutants. The solution of benzophenone-3 at a concentration of 5 mg/dm3 was characterized by the highest toxic effects against both bacteria, crustaceans and vascular plants.
Źródło:
Inżynieria Ekologiczna; 2017, 18, 3; 83-90
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Obniżanie twardości odpływów z oczyszczalni ścieków komunalnych za pomocą filtracji membranowej
Reducing the hardness of effluents from urban wastewater treatment plant by use membrane filtration
Autorzy:
Dudziak, M.
Kudlek, E.
Powiązania:
https://bibliotekanauki.pl/articles/127166.pdf
Data publikacji:
2018
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
odpływ z oczyszczalni ścieków komunalnych
twardość ścieków
filtracja membranowa
effluent from wastewater treatment plant
hardness of wastewater
membrane filtration
Opis:
Odpływ z oczyszczalni ścieków komunalnych może charakteryzować się wysokim stężeniem zarówno soli wapnia, jak i magnezu, powodującym twardość tego strumienia wodnego. Będzie to dotyczyło głównie lokalizacji, gdzie występują systemy dystrybucji wody bazujące na ujęciach wód podziemnych. Wykorzystywanie twardej wody m.in. w gospodarstwach domowych powoduje, że powstające w wyniku działalności bytowej ścieki będą również charakteryzować się twardością. Twardość ścieków nie jest wskaźnikiem normatywnym. Jest to jednak istotny aspekt badawczy w obszarze odzyskiwania wody ze ścieków. W pracy podjęto badania nad obniżeniem twardości ogólnej odpływu z wybranej oczyszczalni ścieków zlokalizowanej na Górnym Śląsku w Polsce. W badaniach wstępnych określono, że odpływ z badanej oczyszczalni ścieków, według powszechnej klasyfikacji twardości wód, jest jak woda twarda (350-550 mg CaCO3/dm3). Do obniżenia twardości odpływu ścieków zaproponowano filtrację membranową, w tym nanofiltrację i odwróconą osmozę. Procesy prowadzono porównawczo z wykorzystaniem rurowych membran kompozytowych firmy PCI Membrane System Inc. Do nanofiltracji zastosowano membranę AFC-30, a do odwróconej osmozy AFC-80. W obu przypadkach ciśnienie transmembranowe wynosiło 2,0 MPa, a temperatura i prędkość liniowa nadawy odpowiednio 20 °C i 3,4 m/s. Wykazano, że ścieki oczyszczone zarówno w procesie odwróconej osmozy, jak i w nanofiltracji były bardzo miękkie. Można więc rozważyć ich wykorzystanie np. na potrzeby gospodarcze. Jednak pod względem wydajności membrany korzystniejszy był proces nanofiltracji.
The effluents from urban wastewater treatment plant are characterized by high concentrations of both calcium and magnesium salts which contribute to the hardness of this particular water flux. It applies primarily to places where the distribution systems draw water from underground sources. Using hard water, for instance, in households causes the domestic wastewater to be hard as well. The hardness of wastewater is not a normative indicator. However, it is an important scientific aspect in the field of water reclamation. As part of this work, research of the reduction of the overall hardness of effluent from the selected urban wastewater treatment plant in the Upper Silesia (Poland) was commenced. After the preliminary tests it was determined that, according to the common water hardness classification, the hardness of effluent from the researched treatment plant equals the hardness of hard water (350-550 mg CaCO3/dm3). In order to reduce the hardness of wastewater effluent a membrane filtration, including nanofiltration and reverse osmosis, was proposed. The processes were performed comparatively with the use of composite pipe membranes of PCI Membrane System Inc. (USA). The membrane used for nanofiltration was AFC-30 and the one for reverse osmosis was AFC-80. In both cases the transmembrane pressure was 2.0 MPa, while temperature and feed linear velocity amounted to 20 °C and 3.4 m/s, respectively. It was determined that after both the reverse osmosis and nanofiltration the treated wastewaters were very soft. Therefore, the use of these processes, for instance, for productive purposes, may be considered. It should also be borne in mind that the nanofiltration process was more favorable in terms of membrane effectiveness.
Źródło:
Proceedings of ECOpole; 2018, 12, 1; 149-156
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative studies on elimination of estrogens and xenoetrogens by the oxidation processes
Badania porównawcze rozkładu estrogenów i ksenoestrogenów w procesach utleniania
Autorzy:
Dudziak, M.
Burdzik-Niemiec, E.
Powiązania:
https://bibliotekanauki.pl/articles/388776.pdf
Data publikacji:
2014
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
elimination of organic micropollutants
EDCs
17ß-estradiol
17α-ethinylestradiol
bisphenol A
wastewater treatment
photolysis
photolysis and ozonation
eliminacja mikrozanieczyszczeń
bisfenol A
17α-etynyloestradiol
oczyszczanie ścieków
fotoliza
fotoliza i ozonowanie
Opis:
The presence of organic micropollutants, especially the substances interfering with hormonal processes termed as endocrine disrupting chemicals EDCs, in surface waters is a potential threat to life and living organisms, including humans. Hazardous biological activity of these compounds (including toxicity) and high resistance to biodegradation necessitate research on their removal in conventional and non-conventional water treatment and wastewater treatment processes. The presented research was motivated by the increasingly frequent reports in the literature regarding the effectiveness of different advanced oxidation processes used for the elimination of micropollutants. In the present study the degradation efficiency for 17ß-estradiol (E2), 17α-ethinylestradiol (EE2) and bisphenol A (BPA) in the photolysis process (UV) and in the coupled photolysis and ozonation process (UV/O3) was evaluated in real and artificial municipal wastewater treatment plant effluent. The obtained results were compared for the degradation efficiency of the test compounds in deionised water. It was determined that both the use of the UV and UV/O3 processes enabled to achieve high degradation efficiencies for 17ß-estradiol and 17α-ethinylestradiol regardless of the treated solution. Degradation of the compounds in the processes occurred in a very short time. On the other hand, the efficiency of elimination of bisphenol A depended on the applied process and the physico-chemical composition of the solution. It was shown that the combination of photolysis with ozonation allowed achieving higher degree of degradation of the test compound than in the case of a single UV process. The study allowed also the identification of substances supporting the degradation of bisphenol A in the UV-O3 process.
Obecność mikrozanieczyszczeń organicznych, a szczególnie substancji zakłócających procesy hormonalne z ang. Endocrine Disrupters Compounds EDCs w wodach powierzchniowych stanowi potencjalne zagrożenie dla zdrowia i życia organizmów żywych, w tym również dla człowieka. Niebezpieczna aktywność biologiczna tych związków (w tym również toksyczność) oraz duża odporność na biodegradację stwarza konieczność prowadzenia badań nad ich usuwaniem w konwencjonalnych i niekonwencjonalnych procesach uzdatniania wody i oczyszczania ścieków. W oparciu o coraz częstsze doniesienia w literaturze przedmiotowej dotyczące skuteczności zastosowania różnych technik zaawansowanego utleniania do eliminacji mikrozanieczyszczeń podjęto badania nad oceną efektywności eliminacji 17ß-estradiolu (E2), 17α-etynyloestradiolu (EE2) oraz bisfenolu A (BPA) z rzeczywistego i modelowego odpływu z oczyszczalni ścieków komunalnych w procesie fotolizy (UV) oraz w procesie łącznym fotoliza i ozonowanie (UV/O3). Uzyskane wyniki badań porównano pod kątem skuteczności rozkładu badanych związków dla wody zdejonizowanej. Określono, że zarówno zastosowanie procesu UV, jak i UV/O3 umożliwiło osiągnięcie wysokich stopni rozkładu dla 17ß-estradiolu oraz 17α-etynyloestradiolu bez względu na rodzaj oczyszczanego roztworu. Rozkład związków następował w bardzo krótkim czasie trwania procesów. Natomiast, efektywność eliminacji bisfenolu A zależała od zastosowanego procesu oraz składu fizykochemicznego roztworu. Wykazano, że połączenie fotolizy z ozonowaniem umożliwiło osiągnięcie wyższego stopnia rozkładu badanego związku, niż w przypadku pojedynczego procesu UV. Przeprowadzone wyniki badań umożliwiły również identyfikację substancji wspomagających rozkład bisfenolu A w procesie UV/O3.
Źródło:
Ecological Chemistry and Engineering. A; 2014, 21, 2; 189-198
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ultrafiltracja z membranami modyfikowanymi i klasyczna nanofiltracja w separacji mikrozanieczyszczeń
Ultrafiltration using modified membranes and classic nanofiltration for the separation of micropollutants
Autorzy:
Burdzik-Niemiec, E.
Dudziak, M.
Powiązania:
https://bibliotekanauki.pl/articles/126398.pdf
Data publikacji:
2016
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
separacja mikrozanieczyszczeń
bisfenol A
17α-etynyloestradiol
nanofiltracja
ultrafiltracja
separation of micropollutants
bisphenol A
17α-ethinylestradiol
nanofiltration
ultrafiltration
Opis:
W pracy podjęto badania nad oceną nisko- i wysokociśnieniowej filtracji membranowej pod kątem separacji wybranych mikrozanieczyszczeń, tj. bisfenolu A (BPA) oraz 17α-etynyloestradiolu (EE2). Obydwa związki należą do substancji aktywnych endokrynnie (ang. Endocrine Disrupters Compounds (EDCs)), które niekorzystnie wpływają na organizmy żywe występujące w wodach naturalnych, stąd potrzeba ich skutecznego usuwania z odpływów z oczyszczalni ścieków. W pracy porównawczo badano klasyczną membranę do nanofitracji o symbolu NF-90 firmy Dow Filmtec (USA) oraz wytworzoną membranę ultrafiltracyjną z polieterosulfonu (PES), zmodyfikowaną nanorurkami (SWCNT), oznaczoną jako UF-PES-SWCNT. Oczyszczaniu poddano odpływ modelowy zawierający wzorce badanych mikrozanieczyszczeń w stężeniu 500 μg/dm3. Na podstawie przeprowadzonych badań dotyczących separacji bisfenolu A oraz 17α-etynyloestradiolu w procesie ultra- i nanofiltracji wykazano, że współczynnik retencji zależał zarówno od rodzaju procesu, jak i usuwanego związku. W przypadku membrany nanofiltracyjnej efektywność usuwania BPA wynosiła 90%, a dla EE2 95%. Wartości tego parametru dla membrany ultrafiltracyjnej zmodyfikowanej nanorurkami była nieznacznie niższa, tj. 70% dla BPA i 92% dla EE2. Na podstawie tych wyników stwierdzono, że niezależnie od rodzaju membrany 17α-etynyloestradiol był usuwany w znacznie wyższym stopniu niż bisfenol A. Może to być spowodowane większym powinowactwem tego związku do polimerów membranotwórczych, wynikającym z dużej wartości współczynnika logKow. W ramach badań wykazano również, że membrana ultrafiltracyjna zmodyfikowana nanomateriałami w porównaniu do klasycznej membrany nanofiltracyjnej była mniej podatna na niekorzystne zjawisko foulingu, ale posiadała kilkakrotnie mniejszą wydajność.
During the study, the efficiency of high and low pressure membrane filtration in terms of removal of bisphenol A (BPA) and 17α-ethinylestradiol (EE2) form model effluent containing mentioned micropollutants in the concertation of 500 μg/dm3 were tested. Both compounds are endocrine active substances (Endocrine disrupters Compounds - EDCs), which adversely affects both - living organisms present in the water and the subsequent water treatment processes for the water supply purposes and its final quality. During this study, the high-pressure commercial NF-90 nanofiltartion membrane (Dow Filmtec, USA) and self-prepared polyethersulfone (PES) ultrafiltration membrane modified with nanotubes (PES-SWCNT) were tested. Membrane designated as UF-PES-SWCNT. Based on studies concerning the separation of bisphenol A and 17α-ethinyl estradiol by means of ultra and nanofiltration processes, it has been shown, that the retention degree of tested compounds was dependent on both, the type of the process and the physicochemical properties of the compound to be removed. The efficiency of micropollutants removal in case of nanofiltration membrane reached 90 and 95% for BPA and EE2, respectively. The value of retention degree for modified PES membrane was lower, namely about 70% for BPA and 92% for EE2. Based on obtained results it was found, that regardless of the type of the membrane, 17α-ethinyl estradiol was removed to a greater extent compared with bisphenol A. EE2 has higher affinity for membranogenic polymers because of its higher logKow coefficient. Research has also shown, that modified PES membrane was more resistant to fouling phenomena in comparison with NF-90 membrane.
Źródło:
Proceedings of ECOpole; 2016, 10, 2; 607-615
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania porównawcze rozkładu wybranych estrogenów i ksenoestrogenów w procesie fotokatalizy
Comparative studies on decomposition of selected estrogens and xenoestrogens by photocatalysis processes
Autorzy:
Burdzik-Niemiec, E.
Dudziak, M.
Powiązania:
https://bibliotekanauki.pl/articles/126603.pdf
Data publikacji:
2015
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
fotokataliza
rozkład mikrozanieczyszczeń
bisfenol A
17β-estradiol
17α-etynyloestradiol
photocatalysis
micropollutants decomposition
bisphenol A
17α-ethinylestradiol
Opis:
W pracy podjęto badania nad oceną efektywności rozkładu trzech różnych związków należących do grupy substancji zakłócających procesy hormonalne (Endocrine Disrupters Compounds EDCs), tj. 17β-estradiolu (E2), 17α-etynyloestradiolu (EE2) oraz bisfenolu A (BPA) w procesie fotokatalizy (UV/TiO2). Przedmiotem badań były modelowe odpływy z oczyszczalni ścieków bytowych, zawierające substancje nieorganiczne i opcjonalnie organiczne, do których dodawano badanych mikrozanieczyszczeń w stężeniu 500 μg/dm3. Uzyskane wyniki badań porównano pod kątem skuteczności rozkładu wybranych związków dla wody zdejonizowanej. Wykazano, że na skuteczność procesu fotokatalizy istotny wpływ ma zarówno rodzaj matrycy środowiskowej, jak i właściwości fizykochemicznych usuwanych związków. Najwyższe stopnie rozkładu uzyskano podczas oczyszczania odpływu modelowego zawierającego wyłącznie substancje nieorganiczne. Rozkład bisfenolu A oraz 17α-etynyloestradiolu przekraczał wówczas 90% (po 60-minutowym czasie naświetlania), a 17β-estradiol został rozłożony całkowicie. Zaobserwowane zjawisko można wytłumaczyć obecnością w ściekach modelowych chemicznych substancji nieorganicznych umożliwiających przebieg tzw. fotokatalizy sensybilizowanej. W przypadku odpływu modelowego zawierającego zarówno substancje organiczne, jak i nieorganiczne tego zjawiska nie obserwowano, a efektywność rozkładu mikrozanieczyszczeń była mniejsza. Powyższe obserwacje potwierdzają również uzyskane wyniki rozkładu związków dla wody zdejonizowanej.
This study addressed the degradation efficiency of three different compounds belonging to the group of endocrine disrupting compounds (EDCs), namely 17β-estradiol (E2), 17α-ethinyl estradiol (EE2), and bisphenol A (BPA) in the photocatalysis process (UV/TiO2). The subject of the study was a synthetic municipal waste water treatment plant effluent containing inorganic and optionally organic substances and to which the investigated micropollutants were added at a concentration of 500 mg/dm3. The obtained results were compared in terms of the degradation of the selected compounds in deionized water. It was found that the efficiency of the photocatalysis depends significantly both on the environmental matrix and physico-chemical properties of the compounds present in the treated waste water. The highest degradation efficiency was observed for the synthetic effluent that contained only inorganic substances. The degradation of bisphenol A and 17α-ethinyl estradiol exceeded 90% (after 60-minute irradiation) and 17β-estradiol was decomposed completely. The observed phenomenon can be attributed to the process termed as sensitized photocatalysis, which was enabled by inorganic substances present in the synthetic waste water. This phenomenon was not observed for the synthetic effluent that contained both inorganic and organic substances, and moreover the degradation efficiency of the micropollutans was lower. These observations were also confirmed by the results regarding the decomposition of the compounds in deionized water.
Źródło:
Proceedings of ECOpole; 2015, 9, 2; 551-559
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biodegradacja kwasów tłuszczowych (C8:0 C22:1) zawartych w ściekach komunalnych metodą osadu czynnego
Biodegradation fatty acids (C8:0 C22:1) contain in the municipal wastewater by activated sludge method
Autorzy:
Łobos-Moysa, E.
Dudziak, M.
Powiązania:
https://bibliotekanauki.pl/articles/296909.pdf
Data publikacji:
2011
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
oleje jadalne
kwasy tłuszczowe
ścieki
osad czynny
tlenowa biodegradacja
edible oil
fatty acids
wastewaters
activated sludge
aerobic condition
Opis:
Obecność wyższych kwasów tłuszczowych (WKT) w ściekach może być związana z doprowadzeniem zarówno ścieków przemysłowych, jak i komunalnych. W pierwszym przypadku głównym źródłem tych kwasów są ścieki z przemysłu spożywczego (tłuszczowego, mięsnego). W przypadku ścieków komunalnych źródłem są gospodarstwa domowe oraz zakłady gastronomiczne. W badaniach nad usuwaniem wyższych kwasów tłuszczowych (WKT) ze ścieków metodą biologiczną zastosowano modelowe ścieki składające się z pożywki organiczno-mineralnej oraz zanieczyszczenia dodatkowego spożywczego oleju rzepakowego. Emulsję olejową przygotowywano w płuczce ultradźwiękowej InterSonic IS 5.5. Oznaczane w tak przygotowanych ściekach kwasy pochodziły z bulionu wzbogaconego, który jest wyciągiem mięsnym, oraz oleju roślinnego. Wstępna enzymatyczna hydroliza, prowadzona pozakomórkowo, umożliwia rozłożenie cząsteczki tłuszczu do glicerolu i wyższych kwasów tłuszczowych (WKT). Końcowym produktem w beztlenowym procesie jest dwutlenek węgla i metan, a tlenowym dwutlenek węgla i woda. Proces biodegradacji prowadzono w 3 dm3 bioreaktorach sekwencyjnych w zakresie niskich obciążeń osadu czynnego ładunkiem zanieczyszczeń (od 0,13 do 17 gBZT5/g s.m.o. · d). Efektywność procesu określono na podstawie ubytku kwasów nasyconych C8:0 C22:0 oraz nienasyconych C16:1 C18:2. Największe zmiany w zawartości poszczególnych kwasów w pierwszych godzinach procesu stwierdzono dla kwasu mirystynowego, palmitynowego i stearynowego, a całkowite usunięcie dla oktanowego, dekanowego, behenowego oraz palmitoleinowego i linolowego. Zawartość kwasu oleinowego natomiast ulegała ciągłym wahaniom.
The presence of High Fatty Acids (HFA) in wastewater can be connected with the supply of both, industrial and municipal wastewater. In the first case, the main source of those acids are wastewater coming from grocery industry (fatty and meat industry). In the case of municipal wastewater, the source of HFA are households and gastronomic facilities. Simulated wastewater composed from organic-mineral broth and rape oil were used in the study in order to remove of HFA from wastewater via biological treatment. Oil emulsion was prepared in an InterSonic IS 5.5 ultrasonic washer and lasted for 24 h (based TOC change). The source of HFA was the enriched bullion, which comprised of the meat extract and plant oil. Fats biodegradation may be limited by their physical and chemical properties e.g. insolubility in water. The process starts with the enzymatic hydrolysis which removes fatty acids from the glycerol molecules of triglycerides. The final products in the aerobic process are carbon and water, while in the anaerobic one carbon and methane. The biodegradation process was carried out in 31 sequential bioreactors under low activated sludge load condition (0,13 ÷ 0,17 gBOD5/gTS · d). The process was stopped after 2, 6, 24 and 72 h followed by activated sludge sedimentation and samples were taken for chemical analysis. The effectiveness of the treatment was established by the decrease of concentration of following saturated acids: octanoic (C8:0), decanoic (C10:0), myristic (C14:0), palmitic (C16:0), stearic (C18:0), behenic (C22:0) and unsaturated acids: palmitoleic (C16:1), oleic (C18:1), linoleic (C18:2). The highest changes in the concentration of investigated acids in the first several hours of the process were observed for myristic, palmitic and stearic acids whereas the total removal of octanoic, decanoic, behenic, palmitoleic and linoleic acid occurred. The concentration of oleic acid was constantly fluctuating.
Źródło:
Inżynieria i Ochrona Środowiska; 2011, 14, 2; 167-173
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania porównawcze rozkładu wybranych estrogenów i ksenoestrogenów w procesie UV i UV/O3
Comparative studies on elimination of selected estrogens and xenoestrogens by UV and UV/O3 processes
Autorzy:
Dudziak, M.
Burdzik-Niemiec, E.
Powiązania:
https://bibliotekanauki.pl/articles/127443.pdf
Data publikacji:
2015
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
eliminacja mikrozanieczyszczeń
EDCs
bisfenol A
17β-estradiol
17α-etynyloestradiol
oczyszczanie ścieków
fotoliza
fotoliza i ozonowanie
micropollutants elimination
bisphenol A
17α-ethinylestradiol
waste water effluent
photolysis
photolysis with ozonation
Opis:
Obecność mikrozanieczyszczeń organicznych, a szczególnie substancji zakłócających procesy hormonalne (Endocrine Disrupters Compounds EDCs) w wodach powierzchniowych stanowi potencjalne zagrożenie dla zdrowia i życia organizmów żywych, w tym również dla człowieka. Niebezpieczna aktywność biologiczna tych związków (w tym ich toksyczność) oraz duża odporność na biodegradację stwarza konieczność prowadzenia badań nad ich usuwaniem w konwencjonalnych i niekonwencjonalnych procesach uzdatniania wody i oczyszczania ścieków. Na podstawie coraz częstszych doniesień w literaturze przedmiotowej, dotyczących skuteczności zastosowania różnych technik zaawansowanego utleniania do eliminacji mikrozanieczyszczeń, podjęto badania nad oceną efektywności eliminacji 17β-estradiolu (E2), 17α-etynyloestradiolu (EE2) oraz bisfenolu A (BPA) z rzeczywistego odpływu z oczyszczalni ścieków komunalnych w procesie fotolizy (UV) oraz w procesie łącznym fotoliza i ozonowanie (UV/O3). Uzyskane wyniki badań porównano pod kątem skuteczności rozkładu badanych związków dla wody zdejonizowanej. Określono, że zarówno zastosowanie procesu UV, jak i UV/O3 umożliwiło osiągnięcie wysokich stopni rozkładu dla 17β-estradiolu oraz 17α-etynyloestradiolu bez względu na rodzaj oczyszczanego roztworu. Rozkład związków następował w bardzo krótkim czasie trwania procesów, natomiast efektywność eliminacji bisfenolu A zależała od zastosowanego procesu oraz składu fizykochemicznego roztworu. Wykazano, że połączenie fotolizy z ozonowaniem umożliwiło osiągnięcie wyższego stopnia rozkładu badanego związku niż w przypadku pojedynczego procesu UV.
The presence of organic micropollutants, especially endocrine disrupting compounds (EDCs) in surface waters is a potential threat to the health and life of living organisms, including humans. Dangerous biological activity of these compounds (including their toxicity) and high biodegradation resistance leads to investigations on their removal in the conventional and unconventional processes of water purification and sewage treatment, such as UV and UV/O3. Based on the frequent reports in literature, studies on the elimination efficiency of 17β-estradiol (E2), 17α-ethinylestradiol (EE2) and bisphenol A (BPA) from real urban wastewater effluents by means of photolysis (UV) and photolysis with ozonation (UV/O3) processes were undertaken. The obtained results were juxtaposed in terms of the efficiency of these compounds elimination from deionized water. It was established that both process, UV and the combination of UV/O3 resulted in high level of 17β-estradiol and 17α-ethinylestradiol decomposition. Even very short duration of the processes were sufficient for decomposition of the compounds. However, bisphenol A elimination efficiency differed depending on the chemical composition of the solution and kind of the investigated processes. It was indicated that the combination of photolysis and ozonation led to the highest level of compound decomposition.
Źródło:
Proceedings of ECOpole; 2015, 9, 2; 589-595
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Występowanie kwasów tłuszczowych i steroli w środowisku naturalnym
The occurrence of fatty acids and sterols in the natural environment
Autorzy:
Łobos-Moysa, E.
Dudziak, M.
Powiązania:
https://bibliotekanauki.pl/articles/127453.pdf
Data publikacji:
2016
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
środowisko naturalne
monitoring
kwas oleinowy
kwas linolowy
kwas palmitynowy
stigmasterol
β-sitosterol
betulina
environment
oleic acid
linoleic acid
palmitic acid
betulin
Opis:
Postęp w rozwoju technik analitycznych umożliwia obecnie oznaczanie bardzo dużej liczby zanieczyszczeń organicznych występujących w środowisku naturalnym. Część tych zanieczyszczeń jest pochodzenia naturalnego. Aktualnie badania ukierunkowane są głównie na zanieczyszczenia specyficzne, których obecność jest wynikiem antropogenicznego oddziaływania na środowisko naturalne. W celu oceny występowania specyficznych zanieczyszczeń i mikrozanieczyszczeń w środowisku naturalnym, tj. wybranych kwasów tłuszczowych nienasyconych - oleinowego i linolowego oraz kwasu nasyconego - palmitynowego, a także steroli stigmasterolu i β-sitosterolu oraz betuliny, opracowano techniki ich wydzielania i ich chromatograficznej analizy. Analizę jakościowo-ilościową zarówno kwasów tłuszczowych, jak i steroli wykonywano przy użyciu chromatografu GC / ion trap / MS (model Saturn 2100 T firmy Varian) wyposażonego w kolumnę chromatograficzną VF-5ms (Varian). Do wydzielania związków zastosowano różne techniki ekstrakcji. W przedstawionych w pracy badaniach prowadzono monitoring występowania zanieczyszczeń w wodach powierzchniowych Górnego Śląska (Wójtowianka (Doa), Potok Rokitnicki, rzeka Bytomka, rzeka Kłodnica i Kanał Gliwicki) w okresie od stycznia do czerwca 2015 roku.
Nowadays, advances in the analytical techniques allow the determination of hundreds of organic pollutants present in the environment. Some of organic pollutants are of natural origin. Although the current study are mainly aimed at specific pollution, the presence of which is the result of anthropogenic impacts on the environment. In order to assess the appearance of specific pollutants and micropollutants in the environment ie the selected unsaturated fatty acids: oleic, linoleic, saturated acid: palmitic and sterols: stigmasterol, β-sitosterol and betulin, the techniques for their isolation and analysis have been developed. Quality and quantity analysis of fatty acids and sterols was carried out using GC/ion trap/MS chromatographic system (model Saturn 2100 T, Varian) equipped with a chromatography column VF-5ms (Varian). Various extraction techniques have been used for isolation of the pollutants. In this study the monitoring of level of contamination in surface water of Upper Silesia (Wójtowianka (Doa) Stream, Rokitnica Stream, Bytomka River, Klodnica River and Gliwice Channel) was conducted in the period from January to June in the 2015.
Źródło:
Proceedings of ECOpole; 2016, 10, 1; 209-217
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative studies on decomposition of selected estrogens and xenoestrogens by photocatalysis processes
Badania porównawcze rozkładu wybranych estrogenów i ksenoestrogenów w procesie fotokatalizy
Autorzy:
Burdzik-Niemiec, E.
Dudziak, M.
Powiązania:
https://bibliotekanauki.pl/articles/388989.pdf
Data publikacji:
2015
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
photocatalysis
micropollutants decomposition
bisphenol A
17β-estradiol
17α-ethinylestradiol
fotokataliza
rozkład mikrozanieczyszczeń
bisfenol A
17α-etynyloestradiol
Opis:
Comparative Studies on Decomposition of Selected Estrogens and Xenoestrogens by Photocatalysis ProcessesAbstract: This study addressed the degradation efficiency of three different compounds belonging to the group of endocrine disrupting compounds (EDCs), namely 17β-estradiol (E2), 17α-ethinyl estradiol (EE2), and bisphenol A (BPA) in the photocatalysis process (UV/TiO2). The subject of the study was a synthetic municipal waste water treatment plant effluent containing inorganic and optionally organic substances and to which the investigated micropollutants were added at a concentration of 500 μg/dm3. The obtained results were compared in terms of the degradation of the selected compounds in deionized water. It was found that the efficiency of the photocatalysis depends significantly both on the environmental matrix and physico-chemical properties of the compounds present in the treated waste water. The highest degradation efficiency was observed for the synthetic effluent that contained only inorganic substances. The degradation of bisphenol A and 17α-ethinyl estradiol exceeded 90 % (after 60-minute irradiation) and 17β-estradiol was decomposed completely. The observed phenomenon can be attributed to the process termed as sensitized photocatalysis, which was enabled by inorganic substances present in the synthetic waste water. This phenomenon was not observed for the synthetic effluent that contained both inorganic and organic substances, and moreover the degradation efficiency of the micropollutans was lower. These observations were also confirmed by the results regarding the decomposition of the compounds in deionized water. In order to describe the course of photocatalytic oxidation reaction rate constants were determined as well as degradation half-lives using the Langmuir-Hinshelwood kinetic model.
W ramach pracy podjęto badania nad oceną efektywności rozkładu trzech różnych związków należących do grupy substancji zakłócających procesy hormonalne (z ang. Endocrine Disrupters Compounds EDCs), tj. 17β-estradiol (E2), 17α-etynyloestradiol (EE2) oraz bisfenol A (BPA) w procesie fotokatalizy (UV/TiO2). Przedmiotem badań były modelowe odpływy z oczyszczalni ścieków bytowych zawierające substancje nieorganiczne i opcjonalnie organiczne, do których dodawano badane mikrozanieczyszczenia w stężeniu 500 μg/dm3. Uzyskane wyniki badań porównano pod katem skuteczności rozkładu wybranych związków dla wody zdejonizowanej. Wykazano, że na skuteczność procesu fotokatalizy istotny wpływ ma zarówno rodzaj matrycy środowiskowej, jak i właściwości fizykochemicznych usuwanych związków. Najwyższe stopnie rozkładu uzyskano podczas oczyszczania odpływu modelowego zawierającego wyłącznie substancje nieorganiczne. Rozkład bisfenolu A oraz 17α-etynyloestradiolu przekraczał wówczas 90 % (po 60-minutowym czasie naświetlania), a 17β-estradiol został rozłożony całkowicie. Zaobserwowane zjawisko można wytłumaczyć obecnością w ściekach modelowych chemicznych substancji nieorganicznych umożliwiających przebieg tzw. fotokatalizy sensybilizowanej. W przypadku odpływu modelowego zawierającego zarówno substancje organiczne, jak i nieorganiczne tego zjawiska nie obserwowano, a efektywność rozkładu mikrozanieczyszczeń była mniejsza. Powyższe obserwacje potwierdzają również uzyskane wyniki rozkładu związków dla wody zdejonizowanej. W celu opisu przebiegu fotokatalitycznego utleniania wyznaczono stałe szybkości reakcji oraz czasy połowicznego rozkładu posługując się kinetyką modelu Langmuira-Hinshelwooda.
Źródło:
Ecological Chemistry and Engineering. A; 2015, 22, 4; 457-467
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ matrycy środowiskowej na efektywność usuwania wybranych estrogenów i ksenoestrogenów w procesie nanofiltracji
The influence of water matrix on the separation of selected estrogens and xenoestrogens by nanofiltration
Autorzy:
Burdzik-Niemiec, E.
Dudziak, M.
Powiązania:
https://bibliotekanauki.pl/articles/400222.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
substancje aktywne biologicznie
17β-estradiol
17α-etynyloestradiol
bisfenol A
proces nanofiltracji
eliminacja mikrozanieczyszczeń
biological active substances
17α-ethinylestradiol
bisphenol A
nanofiltration
elimination of micropollutants
Opis:
Aktualnie nieograniczony dostęp do czystej i niedrogiej wody jest jednym z podstawowych celów humanitarnych. Jednakże ze względu na m.in. wzrost urbanizacji, zanieczyszczenie zasobów wodnych, niewłaściwe zarządzanie gospodarką wodną, zmiany klimatyczne oraz wzrastającą liczbę ludności cel ten wciąż pozostaje wyzwaniem 21-ego wieku. W związku z powyższym skuteczne uzdatnianie wód powierzchniowych stało się jednym z priorytetowych zadań inżynierii i ochrony środowiska. W tym zakresie poszukiwane są także rozwiązania zmierzające do ograniczenia liczby i stężenia zanieczyszczeń, w tym mikrozanieczyszczeń organicznych trafiających do wód powierzchniowych np. wraz z odpływami z oczyszczalni ścieków komunalnych. Efektywność usuwania mikrozanieczyszczeń w konwencjonalnych procesach oczyszczania ścieków jest bardzo często niewystarczająca. W oparciu o powyższe informacje w ramach niniejszej pracy podjęto badania nad oceną efektywności wysokociśnieniowej filtracji membranowej w aspekcie usuwania 17β-estradiolu, 17α-etynyloestradiolu i bisfenolu A z różnych matryc wodnych, w tym modelowego i rzeczywistego odpływu ścieków. Badane związki różniły się pochodzeniem i właściwościami fizykochemicznymi. W pracy badano zarówno odpływ modelowy jak i rzeczywisty. Uzyskane wyniki badań porównano pod kątem skuteczności usunięcia badanych mikrozanieczyszczeń dla roztworu sporządzonego na bazie wody zdejonizowanej. W ramach pracy wykorzystano komercyjną membranę do nanofiltracji HL firmy GE Osmonics (USA). Ciśnienie transmembranowe procesu wynosiło 2,0 MPa. Usuwane wiązki oznaczano z użyciem ekstrakcji do fazy stałej SPE oraz analizy chromatograficznej HPLC. Wykazano, że współczynnik retencji badanych związków zależał od rodzaju oczyszczanej matrycy wodnej oraz właściwości samego związku takich jak hydrofobowość/ hydrofilowość (określana poprzez wartość logKow) oraz masa molowa. Zaobserwowano wyższą retencję badanych związków w przypadku filtracji odpływu rzeczywistego, niż dla odpływu modelowego czy też wody zdejonziowanej. Wskazuje to na występowanie dodatkowych zjawisk wpływających na separację mikrozanieczyszczeń. Wymienić tu można np. tworzenie kompleksów pomiędzy cząsteczkami badanych związków i innymi wielkocząsteczkowymi substancjami organicznymi obecnymi w filtrowanych roztworach oraz powstawanie tzw. membrany wtórnej o porowatości mniejszej niż pory pierwotnej membrany, co przyczynia się do uzyskania większej retencji mikrozanieczyszczeń.
Nowadays unlimited access to clean and affordable water is one of the fundamental humanitarian principles. However, due to the urbanization, pollution of water resources, poor water management, climate change and population growth, this goal still remains the challenge of the 21st century. Therefore, the effective treatment of surface waters has become one of the priority task of engineering and environmental protection. The solutions to reduce the number and concentration of pollutants, including organic micropollutants getting into surface waters, for example with outflows from municipal sewage treatment plant, are still sought. The efficiency of micropollutants removal in conventional water treatment processes is often insufficient. Based on the above information, under this study, the assessment of the efficiency of the high-pressure membrane filtration in terms of the removal of 17β-estradiol, 17α-ethinylestradiol and bisphenol A from different water templates were evaluated. Tested compounds differed primarily in its origin and solubility in water. In the study both, the model and actual outflow were tested. The results were compared in terms of the effectiveness of studied micropollutants removal from a solution made on the basis of deionized water. During the study, the commercial high-pressure filtration HL membrane (GE Osmonics) was tested. The driving force of the processes were transmembrane pressure of 2.0 MPa. Removed compounds were assayed using HPLC chromatography preceded by a solid phase extraction SPE. It has been shown, that the retention degree of tested compounds depended on the type of purified water template and physico-chemical properties of individual compounds such as hydrophobicity/hydrophilicity (determined by the value of the logKow) and molar mass. Higher retention degrees of tested compounds were observed during the actual outflow filtration of actual outflow in comparison with those found for model one or deionized water. It indicates, that there are additional phenomenon affecting the separation of micropollutants, i.e. the formation of complexes between molecules of tested compounds and other macromolecular organic substances present in the solution and the formation of so-called secondary membrane having a lower porosity than the porosity of primary one, which contributes to a greater retention of micropollutants.
Źródło:
Inżynieria Ekologiczna; 2017, 18, 1; 27-35
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie metody GC-MS do oznaczania zawartości kwasów tłuszczowych w ściekach zanieczyszczonych olejami jadalnymi
The application of gc-ms method for determination of fatty acids concentrations in wastewater containing eatable oils
Autorzy:
Łobos-Moysa, E.
Dudziak, M.
Powiązania:
https://bibliotekanauki.pl/articles/296859.pdf
Data publikacji:
2011
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
kwasy tłuszczowe
GC-MS
ekstrakcja ciecz-ciecz
analiza ścieków zaolejonych
oleje jadalne
fatty acids
liquid-liquid extraction
oil wastewater analysis
edible oil
Opis:
Ocenie poddano metodę oznaczania kwasów tłuszczowych w ściekach zaolejonych. Kwasy tłuszczowe wydzielano, stosując ekstrakcję ciecz-ciecz dichlorometanem, którą poprzedzono estryfikacją analitów w wodzie roztworem BF3 w metanolu. Do analizy jakościowo-ilościowej ekstraktu użyto GC-MS. Opracowana metoda umożliwia rozdział i identyfikację 12 kwasów tłuszczowych, w tym nasyconych: oktanowy (C8:0), dekanowy (C10:0), mirystynowy (C14:0), palmitynowy (C16:0), stearynowy (C18:0), arachidowy (C20:0), behenowy (C22:0) i lignocerynowy (C24:0), oraz nienasyconych: palmitoleinowy (C16:1), oleinowy (C18:1), linolowy (C18:2) i erukowy (C22:1). Granica oznaczenia metody była w zakresie od 6,3 do 35 µg/dm3 w zależności od badanego związku. Opisana metoda została z powodzeniem zastosowana do oznaczeń kwasów tłuszczowych w ściekach modelowych i komunalnych.
A method for determination of fatty acids in oil wastewater, extracted with dichloromethane, was developed. In research lipid standards of following saturated acids were used: octanoic (C8:0), decanoic (C10:0), lauric myristic (C14:0), palmitic (C16:0), stearic (C18:0), arachidic (C20:0), behenic (C22:0), lignoceric (C24:0) and unsaturated acids: palmitoleic (C16:1), oleic (C18:1), linoleic (C18:2), erucic (C22:1). Fatty acids were esterified using BF3 methanolic solution and gas chromatography-mass spectrometry analysis was peformed. Limite of aqua nitrification was in range from 6.3 to 35 µg/dm3. The measurements characterized with the high degree of analytes recovery, which exceeded 69%. The precision of measurements below 15% was satisfied. The method was successfully applied to the wastewater containing eatable oils. 4 fatty acids (palmitic, stearic, oleic and linoleic) were analysed in the treated municipal watewaters collected in the mechanical-biological watewater treatment plant in Silesia (Poland). Their concentration varied from 0 to 1702 µg/dm3. The same acids were analysed in the symulated wastewaters with rape oil but in low concentrations form 0 to 250 µg/dm3.
Źródło:
Inżynieria i Ochrona Środowiska; 2011, 14, 3; 275-280
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of water matrix on the retention of pharmaceuticals by high-pressure membrane filtration
Wpływ matrycy wodnej na retencję farmaceutyków w wysokociśnieniowej filtracji membranowej
Autorzy:
Kudlek, E.
Bohdziewicz, J.
Dudziak, M.
Powiązania:
https://bibliotekanauki.pl/articles/388943.pdf
Data publikacji:
2015
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
diclofenac
ibuprofen
carbamazepine
nanofiltration
diklofenak
karbamazepina
nanofiltracja
Opis:
High-pressure membrane processes, including nanofiltration and reverse osmosis, allow for the removal of a wide range of organic micropollutants (including pharmaceutical compounds) from water streams. Those processes also may be an effective method for in-depth treatment of water containing pharmaceutical compounds. The paper presents a comparison of retention of selected pharmaceuticals from the group of non-steroidal and anti-inflammatory drugs, ie ibuprofen and diclofenac and psychotropic drugs – carbamazepine, present in various aqueous matrices in the nanofiltration process. Deionized water based solutions as well as model and real wastewater effluents after biological treatment processes were subjected to the filtration process. The nanofiltration process was carried out in a cross-flow tubular membrane filtration system. Three polyamide membranes AFC30, AFC40 and AFC80 from PCI Membrane System Inc were used. It has been found, that the retention of pharmaceutical compounds increased with the membrane filtration time, regardless of the composition of the treated aqueous matrix. Moreover, the presence of inorganic compounds and high-molecular organic substances had a positive effect on the membrane separation process of micropollutants.
Wysokociśnieniowe procesy membranowe, do których zaliczamy nanofiltrację i odwróconą osmozę, pozwalają na oczyszczenie strumieni wodnych z szerokiej gamy mikrozanieczyszczeń organicznych. Mogą znaleźć również zastosowanie w doczyszczaniu wód pod kątem eliminacji związków farmaceutycznych. W pracy przedstawiono porównanie stopnia retencji wybranych farmaceutyków z grupy niesteroidowych leków przeciwbólowych i przeciwzapalnych, tj. ibuprofen i diklofenak oraz leków psychotropowych – karbamazepina, obecnych w różnych matrycach wodnych w procesie nanofiltracji. Oczyszczaniu poddano roztwory sporządzone na bazie wody zdejonizowanej oraz modelowy i rzeczywisty odpływ po biologicznym oczyszczaniu ścieków. Proces nanofiltracji prowadzono w układzie filtracji krzyżowej przy zastosowaniu rurowego modułu membranowego. Oceniono efektywność procesu przy wykorzystaniu trzech poliamidowych membrana, tj. AFC30, AFC40 i AFC80 firmy PCI Membrane System Inc. Określono, że wraz z czasem filtracji membranowej wzrasta stopień retencji badanych związków farmaceutycznych niezależnie od składu oczyszczanej matrycy wodnej. Ponadto stwierdzono, że obecność w roztworze związków nieorganicznych oraz wysokocząsteczkowych substancji organicznych wpływa korzystnie na proces membranowej separacji mikrozanieczyszczeń.
Źródło:
Ecological Chemistry and Engineering. A; 2015, 22, 4; 469-479
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of selected nonsteroidal anti-inflammatory drugs in the aquatic environment
Oznaczanie wybranych niesteroidowych leków przeciwbólowych i przeciwzapalnych w środowisku wodnym
Autorzy:
Kudlek, E.
Bohdziewicz, J.
Dudziak, M.
Powiązania:
https://bibliotekanauki.pl/articles/953514.pdf
Data publikacji:
2014
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
diclofenac
ibuprofen
SPE
HPLC-UV
GC-MS (EI)
diklofenak
ekstrakcja SPE
Opis:
The presence of pharmaceutical compounds in the aquatic environment requires the development of an effective monitoring method. The paper presents the developed procedure of determination of pharmaceutical compounds selected from the group of nonsteroidal anti-inflammatory drugs – ibuprofen and diclofenac. To isolate selected compounds from the tested water the solid phase extraction (SPE) was employed. The quantitative and qualitative analysis was carried out by high performance liquid chromatography HPLC (UV) as well as gas chromatography coupled with mass spectrometry with electron ionization GC-MS (EI). Described analytical procedures allows to separate and quantificat pharmaceutical mixtures with a satisfactory reproducibility and accuracy. The values of the recovery degree confer the possibility of the complete quantitative control of tested pharmaceuticals in water samples. The described method can be used to control the analytical processes of natural water purification and wastewater treatment from pharmaceutical compounds.
Obecność związków farmaceutycznych w środowisku wodnym wymusza opracowanie skutecznej metody ich monitoringu. W pracy przedstawiono opracowany sposób oznaczenia wybranych związków farmaceutycznych z grupy niesteroidowych leków przeciwbólowych i przeciwzapalnych, tj. ibuprofenu i diklofenaku. Do wydzielenia analitów zastosowano ekstrakcję do fazy stałej (SPE), a do analizy jakościowo-ilościową wysokosprawną chromatografię cieczową HPLC (UV) oraz chromatografię gazową sprzężoną z detektorem masowym (GC-MS). Opracowana procedura analityczna umożliwia rozdział i oznaczenie ilościowe mieszaniny związków farmaceutycznych z zadowalającą powtarzalnością i dokładności ą. Wyznaczone wartości stopni odzysku dają możliwość pełnej kontroli ilościowego oznaczenia badanych farmaceutyków w próbkach wodnych. Powyższa metoda może znaleźć zastosowanie do kontroli analitycznej przebiegu procesów uzdatniania wód naturalnych i doczyszczania ścieków pod kątem eliminacji związków farmaceutycznych.
Źródło:
Ecological Chemistry and Engineering. A; 2014, 21, 2; 177-187
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ matrycy wodnej na retencję związków farmaceutycznych w procesie nanofiltracji
Influence of water matrix on the retention of pharmaceutical compounds by nanofiltration
Autorzy:
Kudlek, E.
Dudziak, M.
Bohdziewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/125822.pdf
Data publikacji:
2016
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
diklofenak
ibuprofen
karbamazepina
nanofiltracja
diclofenac
carbamazepine
nanofiltration
Opis:
Wysokociśnieniowe procesy membranowe, do których zalicza się nanofiltrację i odwróconą osmozę, pozwalają na oczyszczenie strumieni wodnych z szerokiej gamy mikrozanieczyszczeń organicznych. Mogą znaleźć również zastosowanie w doczyszczaniu wód pod kątem eliminacji związków farmaceutycznych. W pracy przedstawiono porównanie stopnia retencji wybranych farmaceutyków z grupy niesteroidowych leków przeciwbólowych i przeciwzapalnych, tj. ibuprofenu i diklofenaku oraz leków psychotropowych - karbamazepina, obecnych w różnych matrycach wodnych w procesie nanofiltracji. Oczyszczaniu poddano roztwory sporządzone na bazie wody zdejonizowanej oraz modelowy i rzeczywisty odpływ po biologicznym oczyszczaniu ścieków. Proces nanofiltracji prowadzono w układzie filtracji krzyżowej przy zastosowaniu rurowego modułu membranowego wyposażonego w poliamidową membranę AFC80 firmy PCI Membrane System Inc. Określono, że wraz z czasem filtracji membranowej wzrasta stopień retencji badanych związków farmaceutycznych niezależnie od składu oczyszczanej matrycy wodnej. Ponadto stwierdzono, że obecność w roztworze związków nieorganicznych oraz wysokocząsteczkowych substancji organicznych wpływa korzystnie na proces membranowej separacji mikrozanieczyszczeń.
High-pressure membrane processes, including nanofiltration and reverse osmosis, allow for the removal of a wide range of organic micropollutants (including pharmaceutical compounds) from water streams. Those processes also may be an effective method for in-depth treatment of water containing pharmaceutical compounds. The paper presents a comparison of retention of selected pharmaceuticals from the group of non-steroidal and antiinflammatory drugs, i.e., ibuprofen and diclofenac and psychotropic drugs - carbamazepine, present in various aqueous matrices in the nanofiltration process. Deionized water based solutions as well as model and real wastewater effluents after biological treatment processes were subjected to the filtration process. The nanofiltration process was carried out in a cross-flow tubular membrane filtration system equipped with the AFC80 polyamide membrane from PCI Membrane System Inc. It has been found, that the retention of pharmaceutical compounds increased with the membrane filtration time, regardless of the composition of the treated aqueous matrix. Moreover, the presence of inorganic compounds and high-molecular organic substances had a positive effect on the membrane separation process of micropollutants.
Źródło:
Proceedings of ECOpole; 2016, 10, 2; 677-684
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Występowanie mikrozanieczyszczeń z makrogrupy PPCPs w wodzie basenowej
The occurence of micropollutants from PPCPs macrogroup in swimming pool water
Autorzy:
Lempart, A.
Kudlek, E.
Dudziak, M.
Powiązania:
https://bibliotekanauki.pl/articles/127547.pdf
Data publikacji:
2018
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
mikrozanieczyszczenia
woda basenowa
GC-MS
SPE
micropollutants
swimming pool water
Opis:
Utrzymywanie mikrobiologicznej jakości wody basenowej, mające na celu zahamowania rozprzestrzeniania się zakażeń i chorób, jest priorytetem dla wszystkich właścicieli i zarządców basenów. Istnieje wiele środków dezynfekcyjnych stosowanych w basenach, które mogą potencjalnie powodować produkcję szerokiej gamy ubocznych produktów dezynfekcji (DBP). Mikrozanieczyszczenia te powstają na skutek reakcji z organicznymi i nieorganicznymi substancjami wprowadzanymi na obiekty przez ich użytkowników. Oprócz wielu ubocznych produktów dezynfekcji, w wodzie basenowej współcześnie identyfikowane są również mikrozanieczyszczenia z makrogrupy PPCPs (ang. Pharmaceuticals and Personal Care Products). Przeprowadzone w pracy chromatograficzne analizy jakościowe wody pobranej z niecki basenu szkolnego wykazały obecność ponad 100 różnych mikrozanieczyszczeń, niezidentyfikowanych dotychczas w tym środowisku, m.in. leków, hormonów, witamin, domieszek przemysłowych czy też składników kosmetyków. Do identyfikacji związków zastosowano metodę chromatografii gazowej z detekcją mas GC-MS z jonizacją elektronową poprzedzoną ekstrakcją do fazy stałej SPE (ang. Solid Phase Extraction).
Maintaining the microbial water quality in order to inhibit the spread of infections and diseases is the priority for every swimming pool owners and managers. There is a number of disinfectants that have been used for swimming pool, which potentially produce a wide range of disinfection by-products (DBPs). These micropollutants are produced by reaction with organic and inorganic matter entering swimming pools by their users. Besides DBPs there are many others micropollutants from PPCPs macro group (Pharmaceuticals and Personal Care Products) that are nowadays identified in swimming pool water. This article describes research conducted on the school swimming pool water. Qualitative chromatographic analysis have shown the presence of more than 100 micropollutants that have not been identified in these environment yet, including medicines, hormones, vitamins, industrial admixtures or cosmetic ingredients. Gas chromatography with GC-MS detection and electron ionization followed by SPE (Solid Phase Extraction) was used to identify the compounds.
Źródło:
Proceedings of ECOpole; 2018, 12, 1; 169-176
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kinetics of the Photocatalytic Decomposition of Bisphenol A on Modified Photocatalysts
Autorzy:
Zawadzki, P.
Kudlek, E.
Dudziak, M.
Powiązania:
https://bibliotekanauki.pl/articles/124140.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
kinetics
photocatalysis
modified photocatalysts
bisphenol A
Opis:
This paper presents the evaluation of the photocatalytic kinetics of bisphenol A decomposition in the presence of commercial titanium(IV) oxide and modified photocatalysts (composites). The following modification methods were used: mechanical mixing, calcination and impregnation. The decomposition process was carried out with the addition of photocatalysts and activated carbon at doses of 100 mg/dm3 and 25 mg/dm3, respectively. The photocatalytic process was performed in a reactor from the Heraeus Company (Warsaw, Poland) with a volume of 0.7 dm3. The reactor was equipped with an immersed medium-pressure mercury lamp with a power of 150 W (λ = 200–580 nm). The degree of bisphenol A decomposition was determined by chromatographic analysis preceded by solid-phase extraction SPE. The qualitative-quantitative analysis was performed using a high-performance liquid chromatograph HPLC (UV detector, λ = 218 nm) from Varian (Warsaw, Poland). The dependence of the BPA decomposition on the duration of irradiation was found, wherein the modified photocatalysts were the most effective (from 75 to 90% after 15 minutes). The order of photocatalyst efficiency has been proposed as follows: TiO2<.sub> < TiO2/AC < Cdextran-TiO2/AC < Cmethanol-TiO2/AC< Cethanol-TiO2/AC < TiO2-AC. The highest degree of decomposition was observed in the presence of TiO2/AC (99%). Numerous studies suggest that the results of the TiO2 photocatalytic oxidation of organic substances fit well with the Langmuir–Hinshelwood (L–H) kinetic model. The kinetic parameters of the photocatalysis process were carried out according to the L-H model. According to the pseudo-first-order parameters, the results showed that the decomposition of bisphenol A was most intensive in the first 15 minutes of the process.
Źródło:
Journal of Ecological Engineering; 2018, 19, 4; 260-268
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elimination of pharmaceutical compounds from municipal wastewater by photocatalysis, microfiltration and nanofiltration
Autorzy:
Kudlek, E.
Bohdziewicz, J.
Dudziak, M.
Powiązania:
https://bibliotekanauki.pl/articles/106011.pdf
Data publikacji:
2015
Wydawca:
Centrum Badań i Innowacji Pro-Akademia
Tematy:
pharmaceuticals
sequential system
photocatalysis
microfiltration
nanofiltration
farmaceutyki
układ sekwencyjny
fotokataliza
mikrofiltracja
nanofiltracja
Opis:
The aim of the study was to develop an innovative method for the removal of selected pharmaceuticals from biologically treated municipal wastewater. The photocatalytic oxidation in the presence of TiO2 was carried out in a reactor irradiated with a UV lamp (power 150 W) and two-stage membrane filtration was also applied. In the first stage the catalyst particles were separated using a microfiltration membrane. In the second stage the wastewater was polished in a semi-industrial installation equipped with a flow-through tubular membrane module with a filter surface area of 240 cm2. The system combining photocatalysis and membrane filtration allowed for complete elimination of the pharmaceuticals.
Źródło:
Acta Innovations; 2015, 16; 12-19
2300-5599
Pojawia się w:
Acta Innovations
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ rodzaju fotokatalizatora i odczynu roztworu na efektywność fotokatalitycznego rozkładu bisfenolu A
Influence of the photocatalyst type and ph of solution on photocatalytic decomposition efficiency of bisphenol A
Autorzy:
Zawadzki, P.
Kudlek, E.
Dudziak, M.
Powiązania:
https://bibliotekanauki.pl/articles/127293.pdf
Data publikacji:
2017
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
bisfenol A
fotokataliza
tlenek tytanu
modyfikowane fotokatalizatory
węgiel aktywny
metanol
bisphenol A
photocatalysis
titanium oxide
modified photocatalysts
activated carbon
methanol
Opis:
Przedstawiono badania porównawcze efektywności rozkładu bisfenolu A (BPA) w procesie fotokatalizy, prowadzonym z udziałem komercyjnego ditlenku tytanu (TiO2) oraz własnych modyfikowanych fotokatalizatorów (kompozytów) otrzymanych na bazie komercyjnego TiO2, węgla aktywnego (AC) oraz alkoholu metylowego (C), tj. TiO2/AC i C-TiO2/AC. Określono wpływ początkowej wartości odczynu roztworu modelowego (w zakresie od 4 do 7) na skuteczność adsorpcji oraz rozkładu badanego mikrozanieczyszczenia za pomocą promieniowania ultrafioletowego (UV). Na podstawie przeprowadzonej analizy chromatograficznej HPLC stwierdzono, że stopień usunięcia bisfenolu A był wyższy w przypadku zastosowania modyfikowanych fotokatalizatorów niż dla komercyjnego TiO2. Prawdopodobnie było to związane z obecnością węgla aktywnego, który w układzie TiO2-AC czy też C-TiO2/AC pełni nie tylko funkcję nośnika fotokatalizatora, ale jest również czynnikiem zwiększającym potencjał adsorpcyjny kompozytu. W oparciu o kinetykę Langmuira-Hinshelwooda (L-H) wyznaczono również parametry kinetyczne przeprowadzonych procesów. Na podstawie obliczonych wartości pseudo-pierwszorzędowych stałych szybkości reakcji udokumentowano, że proces rozkładu bisfenolu A przebiega najintensywniej w pierwszych 15 minutach prowadzenia procesu. Z kolei wartość stałej szybkości reakcji k była wyższa dla modyfikowanych fotokatalizatorów niż dla komercyjnego TiO2. Nie zaobserwowano znaczącego wpływu pH roztworu na adsorpcję oraz rozkład BPA w obecności komercyjnego ditlenku tytanu. Natomiast zarówno sorpcja, jak i proces fotokatalizy realizowany przy udziale modyfikowanych fotokatalizatorów zależały od odczynu roztworu. Największy stopień rozkładu bisfenolu A zaobserwowano, naświetlając roztwór o pH 4.
In this study the photocatalytic degradation of bisphenol A in the presence of titanium dioxide (TiO2) and own modified photocatalysts (composites) based on TiO2, activated carbon (AC) and methyl alcohol (C) i.e. TiO2/AC and C-TiO2/AC were investigated. The effect of initial pH (in the range from 4 to 7) of model solution were determined in order to adsorption effectiveness and decomposition of tested micropollutant under ultraviolet irradiation (UV). Based on chromatographic analysis (HPLC) results it was found that the decomposition of bisphenol A was higher for modified photocatalysts than for commercial TiO2. It was possibly associated with the presence of activated carbon, which in TiO2/AC and C-TiO2/AC system is not only a support for photocatalysts but also increases the adsorption capacity. Based on the Langmuir-Hinshelwood (L-H) model, the kinetic parameters of the photocatalysis process were carried out. According to the pseudo first-order parameters, the results showed that the decomposition of bisphenol A was most intensively in the first 15 minutes of the process. However the value of the k rate was higher for modified photocatalysts than for commercial TiO2. No significant effect of pH on adsorption and BPA decomposition in the presence of commercial titanium dioxide were observed. Whereas, both the sorption and photocatalysis carried out in the presence of modified photocatalysts depended on the pH of model solution. The highest degree of bisphenol A decomposition were observed by irradiating mixture at pH 4.
Źródło:
Proceedings of ECOpole; 2017, 11, 2; 661-669
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmiany toksyczności wody zawierającej wybrane farmaceutyki w procesie utleniania fotokatalitycznego
Toxicity changes of water containing selected pharmaceuticals during the photocatalytic oxidation process
Autorzy:
Bohdziewicz, J.
Kudlek, E.
Dudziak, M.
Powiązania:
https://bibliotekanauki.pl/articles/127378.pdf
Data publikacji:
2014
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
mikrozanieczyszczenia
oczyszczanie strumieni wodnych
toksyczność
test MICROTOX
uboczne produkty utleniania
micropollutants
treatment of water streams
toxicity
MICROTOX test
oxidation by-products
Opis:
Spośród metod badań jakościowych wody i ścieków wymienia się obecnie test MICROTOX®, w którym w charakterze bioindykatora są stosowane bakterie luminescencyjne Vibrio fischeri. W pracy przedstawiono wyniki analizy toksyczności roztworów wodnych, zawierających wybrane farmaceutyki z grupy niesteroidowych leków przeciwzapalnych (diklofenak, ibuprofen) przed i po procesie utleniania fotokatalitycznego. Badano zarówno wpływ stężenia leku, jak i czasu utleniania na zmianę toksyczności próbek wodnych. Stopień usunięcia badanych farmaceutyków został oceniony z użyciem HPLC. Określono, że zastosowanie testu MICROTOX® może być przydatne w ocenie ryzyka wynikającego z możliwości powstawania produktów ubocznych procesu utleniania badanych związków farmaceutycznych.
Nowadays one of the water and wastewater quality test methods is the MICROTOX® test, in which luminescent bacteria Vibrio fisheri are employed as a bioindicator. The study presents the results of the toxicity tests of water solutions containing selected pharmaceuticals from the group of non-steroidal anti-inflammatory drugs (diclofenac, ibuprofen) before and after the photocatalytic oxidation process. The influence of the drug concentration and the oxidation time on the change of the water samples toxicity was examined. The removal degree of chosen pharmaceuticals has been evaluated by HPLC. The obtained results indicate that the MICROTOX® test is thought to be useful in assessment of the risk resulting from the possible formation of by-products of the oxidation of selected pharmaceutical micropollutants.
Źródło:
Proceedings of ECOpole; 2014, 8, 1; 135-140
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analytical control of diclofenac removal in the photocatalytic oxidation process
Kontrola analityczna usuwania diklofenaku w procesie fotokatalitycznego utleniania
Autorzy:
Bohdziewicz, J.
Kudlek, E.
Dudziak, M.
Powiązania:
https://bibliotekanauki.pl/articles/395955.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
diclofenac
photocatalysis
absorbance in UV
organic carbon
stężenie farmaceutyków w ściekach
usuwanie diklofenaku
fotokataliza
utlenianie
absorbancja w UV
węgiel organiczny
Opis:
Continuously increasing pharmaceuticals consumption contributes to the increase of their concentration in the aqueous environment, which is at a level of a few ng/dm3 to several μg/dm3. A numerous group of pharmaceuticals occurring in surface waters are non-steroidal painkillers and anti-inflammatory drugs, which include diclofenac. The paper presents the possibility of the analytical control of diclofenac photocatalytic oxidation process in the aquatic environment. To examine the effectiveness of the process various instrumental methods including HPLC analysis preceded with solid phase extraction SPE, measurements of UV absorbance and total organic carbon were used.
Stale rosnąca konsumpcja farmaceutyków przyczynia się do zwiększenia ich stężenia w środowisku wodnym, które kształtuje się na poziomie od kilku ng/dm3 do kilku μg/dm3 3. Liczną grupę wśród farmaceutyków występujących w wodach powierzchniowych stanowią niesteroidowe leki przeciwbólowe i przeciwzapalne, do których należy m.in. diklofenak. W pracy przedstawiono możliwości kontroli analitycznej procesu fotokatalitycznego utleniania diklofenaku w środowisku wodnym. Do badania skuteczności procesu zastosowano różne metody instrumentalne, w tym analizę HPLC poprzedzoną ekstrakcją do fazy stałej oraz pomiar przewodności właściwej, absorbancji w UV (λ=276 nm) i ogólnego węgla organicznego. W celu określenia obniżenia stężenia usuwanego związku przydatna okazała się analiza chromatograficzna, z którą w dobrym stopniu korespondowały wyniki pomiarów absorbancji w UV. Dowiedziono, że pomiar chromatograficzny charakteryzuje się większą czułością niż pomiar absorbancji wody. Na podstawie pomiarów ogólnego węgla organicznego określono, że degradacja usuwanego związku nie jest kompletna i powstają produkty uboczne tego procesu.
Źródło:
Civil and Environmental Engineering Reports; 2013, 11; 23-30
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An evaluation of the phytotoxicity of filter backwash water coagulation products from a pool water system
Autorzy:
Łaskawiec, E.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/207079.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
phytotptpxicity
swimming pool water
coagulation process
Lepidium sativum
Lemna minor
fitotoksyczność
woda basenowa
proces koagulacji
Opis:
The possibility of using the process of coagulation for purifying the filter backwash water from a swimming pool water system has been presented. The assessment of the process efficiency based on the physicochemical parameters was extended by a phytotoxicity analysis of products (sludges and supernatant liquids) obtained from the coagulation processes. The phytotoxicity of sludges was examined with respect to garden cress (Lepidium sativum) and white mustard (Sinapis alba), while duckweed (Lemna minor) was used for studying liquids. Coagulation process was highly effective in purifying backwash water when the lowest of the studied aluminum coagulant doses (from 7 to 20 mg/dm3) was used. Moreover, the phytotoxicity assessment of backwash water allowed the determination of the hazard toward plants, which would be posed by using the backwash water for plant irrigation. The high stimulation of the growth of plant indices, observed in samples with raw backwash water, was caused by nutritive nitrogen and phosphorus. Their removal, in the case of postcoagulation solutions, significantly contributed to the inhibition of plant growth. In turn, sludges derived from both raw washings and coagulation exhibited phytotoxicity.
Źródło:
Environment Protection Engineering; 2018, 44, 4; 43-56
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena jakości wody basenowej pływalni krytych oraz kąpielisk sezonowych z wykorzystaniem testu MICROTOX®
Qualitative assessment of water in indoor swimming pool and seasonal bathing resorts using MICROTOX® test
Autorzy:
Łaskawiec, E.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/400114.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
uboczne produkty dezynfekcji
woda basenowa
biotest bakteryjny
klasyfikacja toksyczności
disinfection by-products
pool water
bacterial bioassays
toxicity classification
Opis:
Przeprowadzone badania miały na celu określenie wielkości efektu toksycznego na podstawie inhibicji bioluminescencji bakterii Aliivibrio fischeri wywołanej przez zanieczyszczenia obecne w próbkach wody basenowej. Wykorzystywanym narzędziem był test Microtox®. Szybkość z jaką uzyskuje się wyniki w tym bioteście pozwala na stosowanie go w stosunku do wielu toksykantów. Ponadto przeprowadzono pomiar absorbancji w nadfiolecie UV254, którego wartość stanowiła parametr zastępczy dla określenia udziału prekursorów ubocznych produktów dezynfekcji w próbkach. Część próbek charakteryzowała się wysokimi wartościami UV254, w przypadku próbki popłuczyn jednego z badanych obiegów wyniosła 144 m-1. Przedstawione w pracy badania jakości wód basenowych obiektów krytych i odkrytych, z zastosowaniem testu Microtox® pozwoliły na potwierdzenie wpływu takich czynników jak wymiana powietrza czy źródło zasilania obiegów basenowych na jakość wody. W ramach pracy określono, że zanieczyszczenia obecne w wodzie basenowej powoduje jej toksyczność wobec bakterii. Uzyskano niższe wartości toksyczności w przypadku kąpielisk sezonowych, niż w przypadku pływalni krytej. Natomiast nie stwierdzono zależności pomiędzy wysokimi wartościami absorbancji w nadfiolecie UV254 a podwyższoną toksycznością próbek wody. Przeprowadzona ocena toksykologiczna może stanowić przesiewowy test jakości wody basenowej. Istotnym jest by przed jego wykonaniem poddać kontroli zawartość chloru wolnego, ponieważ wysokie stężenia mogą przyczyniać się do uzyskiwania wartości inhibicji bioluminescencji w zakresie wartości dla wysokiej toksyczności.
The tests were to specify the toxic effect on the basis of Vibrio fischeri luminescence inhibition caused by chemical compounds present in pool water samples. The testing tool was Microtox®. This biotest produces quick results thus making it a comfortable tool for testing water for various toxicants. Furthermore, UV254 absorbance measure was carried out and its value was a proxy parameter for defining participation of precursors to disinfection by-products in the samples. Some of the samples had high UV254 values, one of them was 144 m 1. The Microtox® quality tests of indoor and outdoor swimming pool water presented in the paper proved impact of such factors like air exchange or supply of pool water circulation on water quality. Seasonal bathing waters had lower toxicity values. In the context of the work specifies that impurities in the water cause its toxicity. However, there was no relationship between high UV254 absorbance values and higher toxicity of the samples. The toxicological analysis may serve as a screening test of swimming pool water quality. It is of key importance to check the free chlorine value for a water sample. High chlorine concentration can cause higher bioluminescence inhibition values.
Źródło:
Inżynieria Ekologiczna; 2016, 50; 210-216
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Usuwanie wyższych kwasów tłuszczowych (c16:0 - c18:2) podczas biodegradacji ścieków
Removal fatty acids (c16:0 - c18:2) during wastewaters biodegradation
Autorzy:
Łobos-Moysa, E.
Dudziak, M.
Bodzek, M.
Powiązania:
https://bibliotekanauki.pl/articles/400286.pdf
Data publikacji:
2011
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
oleje jadalne
kwasy tłuszczowe
oczyszczanie ścieków
metoda osadu czynnego
warunki tlenowe
edible oil
fatty acids
wastewater treatment
activated sludge method
aerobic condition
Opis:
Obecność wyższych kwasów tłuszczowych (WKT) w ściekach może być związana z doprowadzeniem ścieków przemysłowych, jak i komunalnych. W pierwszym przypadku głównym źródłem tych kwasów są ścieki z przemysłu spożywczego (tłuszczowego, mięsnego), a także w mniejszym stopniu kosmetycznego. W przypadku ścieków komunalnych źródłem są gospodarstwa domowe oraz zakłady gastronomiczne. W badaniach nad usuwaniem WKT ze ścieków metodą biologiczną zastosowano modelowe ścieki składające się z pożywki organiczno-mineralnej oraz oleju rzepakowego. Kwasy te pochodziły z bulionu wzbogaconego, który jest wyciągiem mięsnym oraz oleju roślinnego. Proces biodegradacji prowadzono w 3l bioreaktorach sekwencyjnych w zakresie niskich obciążeń osadu czynnego ładunkiem zanieczyszczeń. Efektywność procesu określono na podstawie ubytku kwasów: palmitynowego (C;16:0), stearynowego (C18:0) oraz oleinowego (C18:1), linolowego (C18:2). W pierwszych godzinach procesu największe zmiany w zawartości poszczególnych kwasów stwierdzono w palmitynowym i stearynowym oraz całkowite usunięcie linolowego. Natomiast zawartość kwasu oleinowego ulegała ciągłym wahaniom.
The presence of High Fatty Acids (HFA) in wastewaters can be connected with the supply of both, industrial and municipal wastewaters. In the first case, the main source of those acids are waste-waters from grocery industry (fatty and meat industry) and, in a smaller extent, cosmetic industry. In case of municipal wastewaters, the source of HFA are households and gastronomic facilities. Simulated wastewaters composed from organic-mineral broth and rape oil were used in the study of the removal of HFA from wastewater via biological treatment. The source of HFA was the enriched bullion, which comprised of the meat extract and plant oil. The biodegradation process was carried out in 31 sequential bioreactors under low activated sludge load conditions. The effectiveness of the treatment was established by the decrease of concentration of following acid: palmitic acid (C16:0) stearic acid (C18:0), oleic acid (C18:1) and linoleic acid (C18:2). The greatest change in concentration of investigated acids in the first several hours of the process run were observed for palmitic and stearic acids together with the total removal of linoleic acid. The concentration of oleic acid was constantly fluctuating.
Źródło:
Inżynieria Ekologiczna; 2011, 24; 99-106
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selection of conditions of water recovery from the stream of washings from the swimming pool water system
Dobór warunków odzysku wody ze strumienia popłuczyn z instalacji wody basenowej
Autorzy:
Łaskawiec, E.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/387996.pdf
Data publikacji:
2017
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
integrated process
washings nanofiltration
coagulation
sedimentation
swimming pool water
Installation
proces zintegrowany
popłuczyny
nanofiltracja
koagulacja
instalacja wody basenowej
Opis:
This study discusses the results of the preliminary tests use an integrated process coagulationsedimentationnanofiltration for the purification washings from swimming pool water treatment circulation. Studies included the effect of the terms and conditions of the preparatory process (coagulation where range of doses of coagulant 1.5–3.0 mgAl/dm3 and sedimentation where the scope of duration 0.5–24 h) on the transport and separating properties nanofiltration membranes. Comparatively, the process of nanofiltration of raw washings has been performed. DK GE Osmonics membrane was used as a nanofiltration membrane. A higher value of volumetric permeate flux was observed during the nanofiltration process for washings after coagulation process with dose 1.5 mgAl/dm3. There has also been significant improvement in transport capacity of the membrane with increased sedimentation time (to 24 hours). The presence of sediment molecules, which contributed to the reduction of the process efficiency during filtration of washings after coagulation with dose 3.0 mgAl/dm3, at the same time they caused a gradual increase in membrane separation capacity. A secondary membrane having a lower porosity than the primary membrane has been produced. The use of the integrated system has improved the transport conditions of the nanofiltration membranes, reduction of residual aluminium concentration, as well as significant improvements in other physicochemical parameters (inter alia reduction the amount of suspended solids and ultraviolet absorbance UV254).
W pracy przedstawiono wyniki badań dotyczących zastosowania zintegrowanego procesu koagulacji–sedymentacji–nanofiltracji do oczyszczania popłuczyn z obiegu uzdatniania wody basenowej. Badania obejmowały ocenę wpływu warunków prowadzenia procesów wstępnych, tj. koagulacji (zakres dawek koagulantu 1,5–3,0 mgAl/dm3) oraz sedymentacji (czas trwania 0,5–24 h) na własności transportowo-separacyjne membran nanofiltracyjnych. Porównawczo przeprowadzono proces nanofiltracji surowych popłuczyn. Obserwowano wyższą wartość objętościowego strumienia permeatu w trakcie procesu nanofiltracji dla popłuczyn po koagulacji (dawka koagulantu 1,5 mgAl/dm3). Stwierdzono znaczącą poprawę zdolności transportowych membrany wraz z wydłużeniem czasu sedymentacji (do 24 h). Obecność cząsteczek osadów, które przyczyniały się do obniżenia wydajności filtracji popłuczyn po koagulacji, w której zastosowano wyższą dawkę koagulantu (3,0 mgAl/dm3), równocześnie spowodowała stopniowy wzrost zdolności separacyjnych membrany – utworzyła się tzw. membrana wtórna charakteryzująca się mniejszą porowatością niż membrana pierwotna. W badanym przypadku zastosowanie układu zintegrowanego pozwoliło na poprawę warunków transportowych membran nanofiltracyjnych, zmniejszenie stężenia glinu pozostałego oraz znaczną poprawę pozostałych parametrów fizykochemicznych (m.in. zmniejszenie ilości zawiesin ogólnych i obniżenie absorbancji w nadfiolecie UV254).
Źródło:
Ecological Chemistry and Engineering. A; 2017, 24, 2; 227-236
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of the possibility of recycling backwashing water from the swimming pool water treatment system
Ocena możliwości recyklingu popłuczyn z systemu oczyszczania wody basenowej
Autorzy:
Łaskawiec, E.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/388489.pdf
Data publikacji:
2016
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
swimming pool water
backwashing
toxicological assessment
physicochemical analysis
biotests
wody basenowe
popłuczyny
ocena toksykologiczna
analiza fizykochemiczna
biotest
Opis:
The paper presents the physicochemical analysis and toxicological assessment of backwashing samples taken after the process of washing filter beds in a raw condition after the process of their aeration and dechlorination. The backwash water under investigation originated from circulation systems existing in two indoor swimming pool facilities. The backwash water, as used at the preliminary and the main stages, was characterized by different physicochemical properties. For toxicological assessment, the Mictorox® bioluminescence inhibition test, the Chaoborus sp. insect larva survival test and the phyto test using Lemna minor fine cilium were involved. The investigation presented in the paper included a preliminary phase focusing on the ecotoxic characterization of backwash water subjected to aeration and dechlorination processes. In turn, at the main stage, the effect of aeration duration on the quality of backwash water in terms of its physicochemical parameters was analyzed. The results of the preliminary stage investigation indicate that backwash water, both in a raw condition and after 30 minutes’ aeration, could not be discharged directly to the environment due to the threat to living organisms caused by its high toxicity. Whereas, using 160 minutes’ aeration duration contributed to a significant improvement in the quality of the backwash water and elimination of its toxic properties with respect to the indicator organisms used. The chemical dechlorination process brought about varying effects. In the case of the Microtox® test, a stimulation of bacterial bioluminescence was noted, but, at the same time, the death of individual insect larva specimens was observed. In spite of the high biomass increase in the Lemna minor test, a gradual discolouration of fronds under the influence of backwash water was observed. Because of the presence of numerous compounds being disinfection by-products, as well as coagulant residues in backwash water deriving from swimming pool systems, it is necessary to seek further solutions that will allow them to be recycled, which will result in a reduction of water consumption and effluent discharges.
W pracy przedstawiono analizę fizykochemiczną oraz ocenę toksykologiczną próbek popłuczyn pobranych po procesie płukania złóż filtracyjnych w stanie surowym po procesie napowietrzania oraz dechloracji. Badane popłuczyny pochodziły z obiegów zlokalizowanych w dwóch obiektach basenowych krytych. Do oceny toksykologicznej włączono test inhibicji bioluminescencji Mictorox®, przeżywalności larw owadów Chaoborus sp. oraz fitotest z wykorzystaniem rzęsy drobnej Lemna minor. Badania obejmowały fazę wstępną, skupiającą się na charakterystyce ekotoksykologicznej popłuczyn poddanych procesom dechloracji oraz napowietrzania. W etapie zasadniczym badań analizowano dodatkowo wpływ czasu napowietrzania na jakość popłuczyn pod względem parametrów fizykochemicznych. Wyniki wstępnego etapu badań sygnalizuj ą, że popłuczyny zarówno w stanie surowym, jak i po 30-minutowym napowietrzaniu nie mogły zostać bezpośrednio odprowadzone do środowiska ze względu na zagrożenie dla organizmów żywych, spowodowane ich wysoką toksycznością. Natomiast zastosowane wydłużenie czasu napowietrzania (160 min) przyczyni ło się do znaczącej poprawy jakości popłuczyn i pozbawienia ich właściwości toksycznych w stosunku do wykorzystanych organizmów wskaźnikowych. Zróżnicowane efekty przyniósł zabieg chemicznej dechloracji. W przypadku testu Microtox® odnotowano stymulację bioluminescencji bakterii, równocześnie zaobserwowano śmierć pojedynczych osobników larw owadów. Pomimo wysokiego przyrostu biomasy w teście z Lemna minor, zaobserwowano stopniowe odbarwienie frondów pod wpływem użytych popłuczyn. Niezbędne jest poszukiwanie dalszych rozwiązań umożliwiających ich recykling, co zapewni ograniczenie zużycia wody oraz odprowadzania ścieków.
Źródło:
Ecological Chemistry and Engineering. A; 2016, 23, 4; 401-410
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dobór warunków odzysku wody ze strumienia popłuczyn z instalacji wody basenowej
Selection of conditions of water recovery from the stream of washings from the swimming pool water system
Autorzy:
Łaskawiec, E.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/125768.pdf
Data publikacji:
2018
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
proces zintegrowany
popłuczyny
nanofiltracja
koagulacja
instalacja wody basenowej
integrated process
washings nanofiltration
coagulation
swimming pool water installation
Opis:
Przedstawiono wyniki badań dotyczących zastosowania zintegrowanego procesu: koagulacja-sedymentacja-nanofiltracja do oczyszczania popłuczyn z obiegu uzdatniania wody basenowej. Badania obejmowały ocenę wpływu warunków prowadzenia procesów wstępnych, tj. koagulacji (zakres dawek koagulantu 1,5-3,0 mg Al/dm3) oraz sedymentacji (przy czasie trwania 0,5-24 h) na własności transportowo-separacyjne membran nanofiltracyjnych. Porównawczo przeprowadzono proces nanofiltracji surowych popłuczyn. Obserwowano wyższą wartość objętościowego strumienia permeatu w trakcie procesu nanofiltracji dla popłuczyn po koagulacji (dawka koagulantu 1,5 mg Al/dm3). Stwierdzono znaczącą poprawę zdolności transportowych membrany wraz z wydłużeniem czasu sedymentacji (do 24 h). Cząsteczki osadów, które przyczyniały się do obniżenia wydajności filtracji popłuczyn po koagulacji, przy wyższej dawce koagulantu (3,0 mg Al/dm3), równocześnie spowodowały stopniowy wzrost zdolności separacyjnych membrany i utworzenie tzw. membrany wtórnej. Przy czym charakteryzowała się ona mniejszą porowatością niż membrana pierwotna. W badanym przypadku zastosowanie układu zintegrowanego pozwoliło na poprawę warunków transportowych membran nanofiltracyjnych, zmniejszenie stężenia glinu pozostałego oraz znaczną poprawę pozostałych parametrów fizykochemicznych (m.in. zmniejszenie ilości zawiesin ogólnych i obniżenie absorbancji w nadfiolecie UV254).
This study discusses the results of the preliminary tests use an integrated process coagulationsedimentationnanofiltration for the purification washings from swimming pool water treatment circulation. Studies included the effect of the terms and conditions of the preparatory process (coagulation where range of doses of coagulant 1.5-3.0 mg Al/dm3 and sedimentation where the scope of duration 0.5-24 h) on the transport and separating properties nanofiltration membranes. Comparatively, the process of nanofiltration of raw washings has been performed. A higher value of volumetric permeate flux was observed during the nanofiltration process for washings after coagulation process with dose 1.5 mg Al/dm3. There has also been significant improvement in transport capacity of the membrane with increased sedimentation time (to 24 hours). The presence of sediment molecules, which contributed to the reduction of the process efficiency during filtration of washings after Edyta Łaskawiec, Mariusz Dudziak i Joanna 184 Wyczarska-Kokot coagulation with dose 3.0 mg Al/dm3, at the same time they caused a gradual increase in membrane separation capacity. A secondary membrane having a lower porosity than the primary membrane has been produced. The use of the integrated system has improved the transport conditions of the nanofiltration membranes, reduction of residual aluminium concentration, as well as significant improvements in other physicochemical parameters (inter alia reduction the amount of suspended solids and ultraviolet absorbance UV254).
Źródło:
Proceedings of ECOpole; 2018, 12, 1; 177-184
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ultrafiltration for Purification and Treatment of Water Streams in Swimming Pool Circuits
Autorzy:
Łaskawiec, E.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/125442.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
swimming pool water
pressure driven
membrane processes
closed circuit
water systems
water treatment systems
water recovery
Opis:
The paper presents possible applications of pressure-driven membrane processes for treatment of swimming pool water and purification of waste streams – washings. Newly identified swimming pool water quality issues are presented that require a modernization of existing technologies. The studies used polymer membranes with the same particle distribution range (50000 Da), but made of different membrane-forming materials: polyvinylidene difluoride (PVDF) and polyether sulfone (PES) for purification of washings. The ultrafiltration process allowed obtaining a high turbidity reduction rate in washings (over 95%), and also a significant reduction of total organic carbon. The effectiveness of the PES membrane was reduced after the process commencement, whereas the separation capacity of the PVDF membrane increased during the studied filtration process. While setting the operational process parameters consideration should be given also to the resistance of used membranes to chlorine present in the swimming pool water. A prolonged exposure of the polyether sulfone membrane to chloride may have caused its gradual damage and degradation of its separation properties.
Źródło:
Journal of Ecological Engineering; 2018, 19, 3; 38-44
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena skuteczności procesu koagulacji w oczyszczaniu popłuczyn z układu cyrkulacji wody basenowej
Evaluation of coagulation process effectiveness in purification of filter washings from swimming pool circulation system
Autorzy:
Łaskawiec, E.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/236975.pdf
Data publikacji:
2018
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
woda basenowa
popłuczyny z filtrów
oczyszczanie
fitotoksyczność
koagulacja
sole glinu
sole żelaza
rzęsa wodna
rzeżucha
swimming pool water
backwash water
purification
phytotoxicity
coagulation
aluminium salts
iron salts
Lemna minor
Lepidium sativum
Opis:
Oceniono możliwości zastosowania procesu koagulacji do oczyszczania popłuczyn z płukania złóż filtracyjnych pracujących w układzie cyrkulacji wody basenowej. Usunięcie części zanieczyszczeń z popłuczyn pozwoliłoby na ich odprowadzanie bezpośrednio do środowiska (np. do nawadniania zieleni) oraz na ograniczenie ilości ścieków odprowadzanych do kanalizacji. W badaniach laboratoryjnych zastosowano cztery różne koagulanty – glinowe (PAX) i żelazowe (PIX) – w zakresie dawek od 1,5 mg/dm3 do 6,0 mg/dm3. Analizie zmian wartości wybranych wskaźników fizyczno-chemicznych (barwa, zawiesiny ogólne, mętność, chlor ogólny, fosfor ogólny, absorbancja w nadfiolecie, ChZT oraz wskaźnik fenolowy) towarzyszyła także analiza fitotoksyczności składników popłuczyn (cieczy nadosadowej i osadów) w stosunku do wybranych roślin wskaźnikowych – rzęsa (Lemna minor) i rzeżucha (Lepidium sativum). Przeprowadzone testy naczyniowe procesu koagulacji pozwoliły na uzyskanie jakości popłuczyn pozwalającej na wprowadzenie ich bezpośrednio do środowiska. Niezależnie od zastosowanego rodzaju koagulantu, poprawa jakości fizyczno-chemicznej popłuczyn została osiągnięta już przy dawkach w zakresie 1,5÷3,0 mg/dm3, przy czym najskuteczniejszy okazał się PAX 25, będący mieszaniną polichlorku glinu i chlorku żelaza(II). Dodatkowo nie odnotowano efektu fitotoksycznego zarówno cieczy nadosadowej, jak i osadów pokoagulacyjnych. Tak oczyszczone popłuczyny mogą być wykorzystane na przykład do nawadniania zieleni na terenach obiektów basenowych.
Applicability of coagulation technique in purification of filter washings from the swimming pool circulation system was evaluated. Removal of some of the contaminants from washings would allow for their discharge directly into the environment (e.g., for irrigation of greenery) and limiting the amount of sewage entering the sewer. In the laboratory studies, four different coagulants were used – aluminum (PAX) and ferric (PIX) – in doses ranging 1.5–6.0 mg/dm3. In addition, the analysis of fluctuations of the values of selected physicochemical parameters (color, general suspensions, turbidity, total chlorine, total phosphorus, ultraviolet absorbance, COD and phenol index) was accompanied by the analysis of washing components (supernatant liquid and sediments) phytotoxicity against the selected indicator plants – eyelash (Lemna minor) and cress (Lepidium sativum). The jar tests conducted throughout the coagulation process resulted in washings of quality adequate to be introduced directly into the environment. Regardless of the type of coagulant used, the improvement of physicochemical parameters of washings was achieved already at doses in the range of 1.5–3.0 mg/dm3, with PAX 25, polyaluminum chloride and iron chloride(II) mixture, being the most effective. In addition, no phytotoxic effect of both the supernatant and post-coagulation sediments was noted. Such purified washings could be employed for example in watering greenery at swimming pool areas.
Źródło:
Ochrona Środowiska; 2018, 40, 1; 57-60
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania wpływu kwasów tłuszczowych i steroli na skuteczność oczyszczania ścieków osadem czynnym w układzie porcjowym
Effect of fatty acids and sterols on the efficiency of wastewater treatment by the activated sludge process in a batch system
Autorzy:
Łobos-Moysa, E.
Dudziak, M.
Bodzek, M.
Powiązania:
https://bibliotekanauki.pl/articles/237291.pdf
Data publikacji:
2010
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczanie ścieków
proces tlenowy
osad czynny
oleje jadalne
kwasy tłuszczowe
sterole
wastewater treatment
aerobic process
activated sludge
edible oil
fatty acids
sterols
Opis:
Doświadczenia przeprowadzono w układzie porcjowym, z użyciem mieszanej populacji osadu czynnego z oczyszczalni ścieków komunalnych. Skuteczność biodegradacji składników ścieków modelowych i rzeczywistych określono na podstawie zmian zawartości zanieczyszczeń specyficznych, tj. kwasów tłuszczowych nienasyconych (linolowego - C18:2 i oleinowego - C18:1) i nasyconych (palmitynowego - C16:0) oraz steroli (stigmasterolu, -sitosterolu i betuliny). Stwierdzono całkowite usunięcie kwasu linolowego z obu rodzajów ścieków. Pozostałe zanieczyszczenia były usuwane w różnym stopniu, np. kwas oleinowy w zakresie 68÷93% (ścieki modelowe) i 90÷91% (ścieki komunalne). Wyjątek stanowił kwas palmitynowy, który podczas biodegradacji ścieków modelowych bez dodatku oleju został usunięty tylko w 32÷44%. Różnica w skuteczności usuwania tych zanieczyszczeń może wynikać z faktu, iż nienasycone kwasy tłuszczowe łatwo ulegają utlenieniu (wraz ze wzrostem ilości wiązań podwójnych). Stwierdzono również, iż skuteczność biodegradacji była zależna od początkowej zawartości kwasów tłuszczowych oraz od obciążenia osadu czynnego ładunkiem tych zanieczyszczeń. W przypadku steroli, które występowały w znacznie mniejszych ilościach niż kwasy tłuszczowe, nie stwierdzono takiej zależności. Wydaje się, że głównym mechanizmem ich usuwania była adsorpcja i biokumulacja.
The experiments were conducted in a batch system, with a mixed microbial population of the activated sludge obtained from a municipal sewage treatment plant. The extent of biodegradation for the polluting species occurring both in the model and real waste-waters was established taking into account the variations in the content of specific pollutants, i.e. unsaturated fatty acids (linoleic - C18:2 and oleinic - C18:1), saturated fatty acid (palmitic - C16:0) and sterols (stigmasterol, [beta]-sitosterol and betuline). The study produced the following findings. Removal of linoleic acid was complete with both types of wastewater. As for the other pollutants, differences were observed in the removal patterns between the two wastewater types: e.g., for oleinic acid the efficiency of removal varied from 68 to 93% in the case of the model wastewater, and from 90 to 91% in the case of the municipal sewage. Palmitic acid was an exception: its removal achieved during biodegradation of the model wastewater with no oil additive only varied between 32 and 44%. The difference in the efficiency of removal can be attributed to the readiness of unsaturated acids to undergo oxidation with the increase in the number of double bonds. The extent of biodegradation was also found to depend on the initial concentrations of the fatty acids and on the load of pollutants received by the activated sludge. In the case of sterols, whose concentrations were noticeably lower than those of fatty acids, no such relation was found to occur. Seemingly, the principal mechanism governing the removal of sterols involved adsorption and bio-accumulation.
Źródło:
Ochrona Środowiska; 2010, 32, 2; 53-56
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oczyszczanie wody popłucznej z instalacji basenowej w jednostkowym membranowym procesie ultrafiltracji oraz w układzie zintegrowanym napowietrzanie-ultrafiltracja
Treatment of aqueous rinsing liquids of the pool water installation in a unit process of membrane ultrafiltration and in the airing-ultrafiltration integrated system
Autorzy:
Łaskawiec, E.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/270649.pdf
Data publikacji:
2016
Wydawca:
Centralny Ośrodek Badawczo-Rozwojowy Aparatury Badawczej i Dydaktycznej, COBRABiD
Tematy:
popłuczyny
woda basenowa
ultrafiltracja
ciśnieniowe procesy membranowe
oczyszczanie strumieni wód odpadowych
washings
pool water
ultrafiltration
pressure driven membrane processes
treatment of streams of wastewater
Opis:
W pracy przedstawiono możliwość wykorzystania membranowego procesu ultrafiltracji do oczyszczania popłuczyn z instalacji basenowych. Badania obejmowały proces jednostkowy ultrafiltracji oraz zintegrowany układ napowietrzanie-ultrafiltracja, który pozwolił na częściowe usunięcie zanieczyszczeń występujących w nadawie. Porównano membrany o zróżnicowanym materiale polimerowym oraz różnej wartości granicznej masy molowej cut-off. Określono wpływ zastosowanego procesu wstępnego na zdolności transportowo-separacyjne membran o różnych własnościach fizyczno-chemicznych. Uzyskano wysoką wydajność hydrauliczną we wszystkich prowadzonych filtracjach (w zakresie od 1,23·10-5 do 1,40·10-7 m³/m²·s). W zakresie usuwania mętności badane układy charakteryzowały się współczynnikiem usunięcia przekraczającym 90%. Odnotowano znaczące usunięcie grupy zanieczyszczeń opisanych przez wskaźnik ogólny, tj. absorbancję w nadfiolecie UV254. Przeprowadzone badania wykazały możliwość wykorzystania ultrafiltracji do odzysku wody basenowej z popłuczyn poprocesowych.
The paper presents the possibility of using the membrane ultrafiltration process for the treatment of washings from pool water systems. The tests included a unit ultrafiltration process and airing-ultrafiltration integrated system which partly removed contamination from the feed material. Membranes of various polymere materials and molar mass cut-off were compared. This helped to determine the influence of the used initial process on transport and separation abilities of the membranes of different physical and chemical features. High hydraulic performance was obtained in all performed filtration actions (1.23·10-5 ÷ 1.40·10-7 m³/m²·s). In respect of fighting turbidity, all tested systems had a removal rate of more than 90%. It was also noted that a significant amount of contamination described by the general indicator, which is specific UV254 absorbance, was removed. The tests proved that ultrafiltration can be used for recovery pool water from post-process washings.
Źródło:
Aparatura Badawcza i Dydaktyczna; 2016, 21, 4; 238-245
2392-1765
Pojawia się w:
Aparatura Badawcza i Dydaktyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena możliwości recyklingu popłuczyn z systemu oczyszczania wody basenowej
Evaluation of the recycling possibility of washings from swimming poool water treatment system
Autorzy:
Łaskawiec, E.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/126852.pdf
Data publikacji:
2018
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
wody basenowe
popłuczyny
ocena toksykologiczna
analiza fizykochemiczna
biotest
swimming pool water
back washing water
toxicological assessment
physicochemical analysis
Opis:
Przedstawiono ocenę fizykochemiczną oraz toksykologiczną próbek popłuczyn surowych (pobranych bezpośrednio po procesie płukania złóż filtracyjnych) po procesie napowietrzania oraz procesie dechloracji. Popłuczyny pobrano z obiegów basenowych dwóch krytych pływalni. Przeprowadzono badania wstępne i zasadnicze, w których popłuczyny charakteryzowały się zróżnicowanymi parametrami fizykochemicznymi. Do oceny toksykologicznej zastosowano test inhibicji bioluminescencji Mictorox®, test przeżywalności larw owadów Chaoborus sp. oraz fitotest z wykorzystaniem rzęsy drobnej Lemna minor. Badania wstępne obejmowały charakterystykę ekotoksykologiczną popłuczyn poddanych procesom napowietrzania oraz dechloracji. W badaniach zasadniczych analizowano wpływ czasu napowietrzania na jakość popłuczyn. Wyniki badań wstępnych wskazywały, że popłuczyny surowe, jak również po 30-minutowym napowietrzaniu nie mogły być bezpośrednio odprowadzone do środowiska naturalnego ze względu na wysoką toksyczność w stosunku do organizmów żywych. Zastosowanie dłuższego czasu napowietrzania (160 minut) przyczyniło się do znacznej poprawy jakości popłuczyn i eliminacji ich właściwości toksycznych w stosunku do organizmów wskaźnikowych. Zróżnicowane efekty uzyskano po procesie chemicznej dechloracji. Odnotowano stymulację bioluminescencji bakterii (testu Microtox®), ale równocześnie zaobserwowano śmierć pojedynczych osobników larw owadów. Pomimo wysokiego przyrostu biomasy w teście z Lemna minor, zaobserwowano stopniowe odbarwienie frondów pod wpływem popłuczyn. Ze względu na zmienność jakości popłuczyn, obecność w nich ubocznych produktów dezynfekcji i koagulacji oraz toksyczne oddziaływanie na organizmy niezbędne jest rozszerzenie badań w zakresie metod umożliwiających ich recykling.
This study discusses the physical and chemical analysis as well as toxicological evaluation of backwashings samples collected after rising raw filter beds, following aeration and dechlorination process. The tested washings were collected at facilities located in two indoor swimming pools. Toxicological evaluation included Mictorox® bioluminescence inhibition assay, Chaoborus sp. larvae survivability test as well as Lemna minor duckweed fito test. The initial stage of the research was focused on eco-toxicological properties of backwashings, subject to aeration and dechlorination processes. The main stage of the research involved additional analysis of the impact of aeration duration on the quality of washings in terms of physical and chemical parameters. The results of the initial stage clearly suggest that both raw washings as well as washings after 30 minutes of aeration are not suitable for direct disposal in the environment due to biohazards resulting from high toxicity of washings. On the other hand extension of the aeration process (160 minutes) contributed to significant improvement of washings quality and removal of toxic properties in relation to the indicator species used in the research. Chemical dechlorination ended with varying results. Microtox® bioluminescence assay resulted in bacteria bioluminescence with simultaneous observation of death of individual larvae. Despite high increase of biomass in Lemna minor test, some gradual decolouration of shoots as the result of washings used. In further solutions for recycling must be sought which will provide reduced water consumption and sewage.
Źródło:
Proceedings of ECOpole; 2018, 12, 1; 185-193
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Treatment of Pool Water Installation Washings in A Flocculation/Ultrafiltration Integrated System
Autorzy:
Łaskawiec, E.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/123294.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
pressure driven membrane processes
washings
flocculation
waste streams treatment
ultrafiltration
Opis:
The article presents the possibilities of employing an integrated flocculation/ultrafiltration system in the treatment of washings generated upon the rinsing of filter beds in pool water installations. Single ultrafiltration process was used as a comparator. Flocculation was carried out using commercial dialuminium pentahydroxychloride solution widely used at pool facilities for the removal of contaminants in flocculation processes. The studies consisted in determination of correlations between the conditions of the flocculation process (variable doses of Al3+ ions: from 4 to 280 mg/L) and the transport/separation characteristics of ultrafiltration membranes. Flocculation was performed at different temperatures of washings i.e. 8, 21, and 30°C for each of the pre-defined doses. Ultrafiltration was highly capable of reducing the turbidity of washings and removing a large group of contaminants as determined by turbidimetry and UV254 absorbance measurements. The studies revealed that the best transport/ separation characteristics of ultrafiltration membranes were obtained in a system in which ultrafiltration was performed following flocculation of washings carried out at 21°C using a 40 mgAl3+/L solution. The turbidity was reduced by ca. 99% and UV absorption was reduced by ca. 94% while the relative volumetric stream of the permeate increased by more than 35% (as compared to the filtration of washings in a single-process system). Membrane ultrafiltration significantly increased the quality of the waste stream consisting of washings from the pool water installation. Pre-processing of washings is required before ultrafiltration in order to limit the blocking of membrane pores. Flocculation may be one of such pre-processing methods.
Źródło:
Journal of Ecological Engineering; 2017, 18, 5; 96-103
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kinetyka fotokatalitycznego rozkładu wybranych mikrozanieczyszczeń organicznych w środowisku wodnym
Kinetics of the photocatalytic degradation of selected organic micropollutants in the water environment
Autorzy:
Kudlek, E.
Dudziak, M.
Kamińska, G.
Bohdziewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/399772.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
fotokataliza
mikrozanieczyszczenia organiczne
kinetyka procesu
photocatalysis
organic micropollutants
process kinetics
Opis:
W pracy przedstawiono ocenę stopnia usunięcia wybranych wielopierścieniowych węglowodorów aromatycznych (antracen, benzo(a)piren), ksenoestrogenów (oktylofenol, pentachlorofenol) oraz związków farmaceutycznych (diklofenak) w procesie heterogenicznej fotokatalizy z ich roztworów wodnych sporządzonych na bazie wody zdejonizowanej. Jako fotokatalizator procesu zastosowano ditlenek tytanu w dawce 100 mg/dm3. Kinetykę procesu wyznaczono w oparciu o równanie Langmuira- Hinsherlwooda, przy założeniu pseudo-pierwszorzędowego przebiegu reakcji rozkładu mikrozanieczyszczeń. Ponadto wykonano analizę toksykologiczną próbek roztworów wodnych badanych związków po procesie ich naświetlania przy użyciu testu Microtox®. Stwierdzono, że wraz ze wzrostem czasu prowadzenia procesu obniżało się stężenie badanych mikrozanieczyszczeń, a stopień ich usunięcia po 60 minutach przekraczał 90%. Analiza kinetyki procesu wykazała, że utlenianie związków zachodziło najintensywniej w pierwszej fazie prowadzenia procesu naświetlania tj. do 10 minuty. Wykonana ocena toksykologiczna potwierdziła niecałkowity rozkład zanieczyszczeń i generowanie ubocznych produktów wpływających na wzrost toksyczności oczyszczanych roztworów wodnych.
The paper presents an assessment of the removal degree of selected polycyclic aromatic hydrocarbons (anthracene, benzo(a)pyrene), xenoestrogens (octylphenol, pentachlorophenol) and pharmaceutical compounds (diclofenac) in the process of heterogeneous photocatalysis of their water solutions, which were prepared on the base of deionized water. Titanium dioxide at a dose of 100 mg/dm3 was used as a photocatalyst of the process. The kinetics of the process was determined based on the Langmuir-Hinsherlwood equation, assuming the pseudo-first-order reaction of micropollutants decomposition. Furthermore a toxicological analysis of water samples of test compounds was performed by the use of the Microtox® test. It has been found that the micropollutant concentrations decreased with the increase of process time and their removal degree after 60 minutes exceeds 90%. The analysis of the proces kinetic showed that the oxidation of the compounds occurred with the greatest intensity in the first stage of the process up to 10 min. The preformed toxicological assessment confirmed the incomplete decomposition of pollutants and the generation of by-products, which contribute to the increase of the toxicity of treated water solutions.
Źródło:
Inżynieria Ekologiczna; 2017, 18, 2; 75-82
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Usuwanie mikrozanieczyszczeń w laboratoryjnym wielofunkcyjnym reaktorze membranowym
Removal of micropollutants in the laboratory multifunctional membrane reactor
Autorzy:
Kudlek, E.
Dudziak, M.
Bohdziewicz, J.
Kamińska, G.
Powiązania:
https://bibliotekanauki.pl/articles/126021.pdf
Data publikacji:
2017
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
reaktor membranowy
promieniowanie UV
ścieki oczyszczone
mikrozanieczyszczenia
membrane reactor
UV irradiation
wastewater effluent
micropollutants
Opis:
Hybrydowe układy oczyszczania ścieków oparte o zaawansowane procesy utleniania i techniki membranowe stanowią alternatywę nie tylko do konwencjonalnych układów oczyszczania strumieni wodnych, ale również do układów sekwencyjnych bazujących na pogłębionych procesach oczyszczania. W pracy przedstawiono ocenę stopnia usunięcia mikrozanieczyszczeń organicznych z grupy wielopierścieniowych węglowodorów aromatycznych - antracenu i bezno(a)pirenu - oraz domieszek przemysłowych, tj. pentachlorofenolu i oktylofenolu, jak również związków farmaceutycznych - diklofenaku z oczyszczonych ścieków bytowo-gospodarczych na poszczególnych etapach cyklu pracy fotokatalitycznego laboratoryjnego wielofunkcyjnego reaktora membranowego. Proces oczyszczania realizowano bez i z dodatkiem katalizatora w postaci komercyjnego ditlenku tytanu. Dobrane parametry pracy reaktora umożliwiły ponad 73% usunięcie badanych mikrozanieczyszczeń w procesie prowadzonym bez dodatku katalizatora. Wprowadzenie półprzewodnika do oczyszczanego roztworu wodnego pozwoliło na kompletne usunięcie pentachlorofenolu, oktylofenolu, bezno(a)pirenu oraz diklofenaku. Wykazano, że zastosowana membrana ultrafiltracyjna pełniła nie tylko rolę przegrody separującej cząsteczki stosowanego katalizatora, ale również pozwalała na zatrzymanie mikrozanieczyszczeń, których współczynniki retencji mieściły się w zakresie od 9% dla pentachlorofenolu do 98% dla bezno(a)pirenu.
Hybrid wastewater treatment systems based on advanced oxidation processes and membrane techniques are an alternative both to conventional water treatment systems and sequential systems based on deep-treatment processes. The paper presents the estimation of the removal rate of organic micropollutants from wastewater effluent at various phases of the photocatalytic laboratory multifunctional membrane reactor. The tested compounds belong to the group of polycyclic aromatic hydrocarbons - anthracene and benzo(a)pyrene, industrial additives i.e. pentachlorophenol and octylphenol, as well as pharmaceuticals - diclofenac. The treatment process was carried out without or with the addition of a catalyst in the form of commercial titanium dioxide. Reactor’s selected operating parameters allowed to remove over 73% of the tested micropollutants in the process carried out without catalyst. The addition of the semiconductor to the treated water solution allowed to remove completely pentachlorophenol, octylphenol, benzo(a)pyrene and diclofenac. It has been shown that the ultrafiltration membrane acts not only as a separation barrier of the catalyst, but also allows for the retention of micropollutants, which removal rate ranged from 9% for pentachlorophenol to 98% for benzo(a)pyrene.
Źródło:
Proceedings of ECOpole; 2017, 11, 2; 525-532
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Usuwanie WWA i ich zachowanie w trakcie mechaniczno-biologicznego oczyszczania ścieków
Removal and fate of PAHs during mechanical-biological wastewater treatment
Autorzy:
Kamińska, G.
Kudlek, E.
Dudziak, M.
Bohdziewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/126459.pdf
Data publikacji:
2016
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
WWA
monitoring
oczyszczanie ścieków
PAHs
wastewater treatment
micropollutants
Opis:
Przedstawiono wyniki monitoringu wielopierścieniowych węglowodorów aromatycznych w ściekach surowych, wstępnie oczyszczonych na stopniu mechanicznym oraz odprowadzanych do środowiska. Obiektem badań były 3 komunalne oczyszczalnie ścieków zlokalizowane w województwie śląskim. Procedura oznaczenia związków obejmowała wydzielenie badanych substancji z próbek ścieków za pomocą ekstrakcji do fazy stałej, a następnie analizę chromatograficzną GC-MS. Przeprowadzone badania pozwoliły również ocenić skuteczność ich usuwania na poszczególnych stopniach oczyszczenia. Spośród 16 badanych WWA największe stężenie w ściekach surowych odnotowano dla pirenu. Tendencja ta została zaobserwowana dla wszystkich trzech badanych oczyszczalni. Stwierdzono również, że w ściekach z oczyszczalni o największej przepustowości zawartość mikrozanieczyszczeń była około 2 razy większa w stosunku do ścieków pobieranych z mniejszych obiektów. Skuteczność usuwania badanych związków podczas mechaniczno-biologicznego oczyszczania ścieków kształtowała się w zakresie od 65 do 97%.
This study presents results of the monitoring of 16 polycyclic aromatic hydrocarbons in raw, primary treated and secondary treated wastewater from 3 WWTPs located in Silesia. The assay procedure of the compounds included the separation of substances from sewage samples by solid phase extraction and chromatographic analysis with GC-MS. Based on calculated concentration of given PAHs in wastewater we determined their removal degree at various stages of treatment. Among 16 studied PAHs the highest concentration in raw sewage was reported for pyrene. This trend was observed for all three studied WWTPs. It was also found that wastewater from the WWTPs with the highest capacity was about 2 times higher in relation to the wastewater collected from smaller objects. The removal efficiency of the studied compounds during mechanical - biological treatment was in the range of 65 to 97%.
Źródło:
Proceedings of ECOpole; 2016, 10, 2; 653-660
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania efektu toksykologicznego fotokatalizatorów
Study of toxicological effect of photocatalysts
Autorzy:
Kudlek, E.
Dudziak, M.
Bohdziewicz, J.
Kamińska, G.
Powiązania:
https://bibliotekanauki.pl/articles/126720.pdf
Data publikacji:
2017
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
TiO2
ZnO
promieniowanie UV
toksyczność roztworu
UV irradiation
toxicity of solution
Opis:
Efektywność rozkładu zanieczyszczeń organicznych w procesie fotokatalizy zależy od szeregu czynników, wśród których decydującą rolę odgrywają zarówno, dobór rodzaju, jak i dawki fotokatalizatora. Do najczęściej opisywanych w literaturze półprzewodników stosowanych w procesach oczyszczania strumieni wodnych zalicza się tlenek tytanu(IV) i tlenek cynku. W pracy przedstawiono zmiany toksyczności wodnych mieszanin fotokatalizatorów bez i w trakcie ich naświetlania promieniami UV o długości fali przekraczającej 300 nm. Badania prowadzono z użyciem czterech półprzewodników, tj. TiO2 jako mieszaniny anatazu i rutylu, TiO2 w postaci czystego anatazu, ZnO oraz ZnO farmaceutycznego w dawce 25, 50, 100 i 200 mg/dm3. Efekt toksyczny oceniono z użyciem biotestu Microtox®. Wykazano, że wraz ze wzrostem czasu napromieniowania mieszaniny ZnO oraz ZnO farmaceutycznego wzrasta odpowiedź toksykologiczna organizmów testowych. Świadczy to o braku stabilności fotochemicznej obu tych półprzewodników oraz dyskwalifikuje ich użycie w przypadku oczyszczania strumieni wodnych odprowadzanych do środowiska naturalnego. Zmiany efektu toksykologicznego nie obserwowano w przypadku mieszanin wodnych z półprzewodnikami, które nie były naświetlane promieniami UV. Również naświetlanie mieszanin zawierających TiO2 bez względu na formę nie wpłynęło na zmianę ich toksyczności.
The efficiency of decomposition of organic pollutants during photocatalytic oxidation process depends on several factors, among which the type and dose of photocatalyst plays a significant role. According to literature, the most commonly used semiconductors in processes of water streams treatment are titanium dioxide and zinc oxide. The paper presents the change in toxicity of aqueous mixtures of photocatalysts unirradiated and irradiated with UV light with wavelength greater than 300 nm. Studies were carried out by the use of four semiconductor i.e. TiO2 as a mixture of anatase and rutile, TiO2 as a pure form of anatase, ZnO and pharmaceutical ZnO at a dose of 25, 50, 100 and 200 mg/dm3. Toxic effects were evaluated using the Microtox® bioassay. It has been demonstrated that the toxic response of the test organisms increases with the increase of the irradiation time of mixtures containing ZnO and ZnO pharmaceutical. That fact indicates a lack of photochemical stability of both semiconductors and disqualifies their use during the treatment of water streams which will be discharged into the environment. Changes in toxicological effects were not observed for semiconductors water mixtures, which were not irradiated with UV light. Also, the UV exposure of mixtures containing TiO2 did not affect any change of their toxicity.
Źródło:
Proceedings of ECOpole; 2017, 11, 1; 201-209
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena skuteczności usuwania wybranych substancji aktywnych biologicznie w procesie nanofiltracji
Effectivness of removal of selected biologically active micropollutants in nanofiltration
Autorzy:
Kamińska, G.
Dudziak, M.
Bohdziewicz, J.
Kudlek, E.
Powiązania:
https://bibliotekanauki.pl/articles/126779.pdf
Data publikacji:
2016
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
substancje aktywne biologicznie
nanofiltracja
nanofiltration
biologically active compounds
Opis:
W pracy podjęto badania nad oceną skuteczności usuwania pięciu różnych związków należących do grupy substancji aktywnych biologicznie, tj. benzo(a)pirenu (BaP), antracenu (ANT), diklofenaku (DCL), pentachlorofenolu (PCP) i oktylofenolu (OP), w procesie nanofiltracji. Przedmiotem badań były modelowe roztwory tych substancji o stężeniu 500 μg/dm3, wykonane na bazie wody zdejonizowanej. Uzyskane wyniki badań porównano pod kątem skuteczności usuwania wybranych związków z syntetycznych i rzeczywistych odpływów z komunalnej oczyszczalni ścieków. Wykazano, że na skuteczność procesu nanofiltracji istotny wpływ ma rodzaj membrany nanofiltracyjnej, właściwości fizykochemiczne usuwanych związków, jak również rodzaj matrycy środowiskowej poddawanej oczyszczaniu. Najwyższą efektywność usuwania zaobserwowano dla benzopirenu w trakcie nanofiltracji wody zdejonizowanej. Współczynniki retencji wynosiły wówczas od 99,82 do 99,94%, co oznacza praktycznie jego całkowite usunięcie. Z kolei dla pozostałych związków z wyjątkiem oktylofenolu zaobserwowano odwrotną tendencję, wyższe współczynniki retencji uzyskano, gdy filtrowanym medium były ścieki syntetyczne lub rzeczywiste. Przeprowadzone badania udokumentowały złożony mechanizm separacji małocząsteczkowych mikrozanieczyszczeń organicznych w procesie nanofiltracji wynikający m.in. z oddziaływań międzycząsteczkowych, efektu sitowego, jak również adsorpcji.
This study addressed the removal efficiency of five different compounds classified as biologically active compounds ie benzo(a)pyrene (BaP), anthracene (ANT), diclofenac (DCL), pentachlorophenol (PCP), octylphenol (OP) in nanofiltration. They were removed from deionized water solution of 500 μg/dm3 and comparatively from synthetic and municipal effluent. It was found that the efficiency of the nanofiltration depends significantly both on type of membrane and the environmental matrix and physic-chemical properties of the compounds present in the treated waste feed. The highest retention was observed for benzo(a)pyrene removed from deionized water. In this case, the retention of BaP varied from 99.82 do 99.94%. For other compounds (excluding octylphenol) we observed an inverse trend, higher retention degrees were obtained when the synthetic or real effluent were filtered. Studies documented a complex mechanism of separation of low molecular weight organic micropollutants in nanofiltration, which could be a result of intermolecular interactions, sieve effect and adsorption.
Źródło:
Proceedings of ECOpole; 2016, 10, 1; 155-164
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of Inorganic Compounds on the Process of Photocatalysis of Biologically Active Compounds
Autorzy:
Kudlek, E.
Dudziak, M.
Bohdziewicz, J.
Kamińska, G.
Powiązania:
https://bibliotekanauki.pl/articles/124427.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
water environment
organic micropollutants
photocatalysis
cations
anions
Opis:
Constant increase in concentration of organic micropollutants in the water environment influences the development of methods for their effective elimination from various matrices released into aquatic ecosystems. One of widely described in literature processes for the decomposition of hardly-biodegradable pollutants is the process of heterogeneous photocatalysis. The paper presents the influence of inorganic substances on the decomposition of polycyclic aromatic hydrocarbons (anthracene and benzo[a]pyrene), industrial admixtures – octylphenol and pharmaceutical compounds – diclofenac in the photocatalysis process conducted in the presence of TiO2. It has been shown that the presence of Cl ions did not affect the photochemical reaction of the micropollutant decomposition. Whereas, the presence of CO32–, SO42– and HPO42– ions inhibited the decolonization of octylphenol and diclofenac, while the degradation efficiency of anthracene and benzo[a]pyrene was reduced only by the presence of CO32– and HCO3 anions. The photooxidation of micropollutants in solutions containing Al3+ oraz Fe3+ cations proceeded with a much lower efficiency than that for solution without inorganic compounds. The analysis of the kinetics of the photocatalytic decomposition of selected micropollutants show a decrease in the reaction rate constant and an increase in their half-life due to the blocking of theactive semiconductor centers by inorganic compounds. In addition,the toxicological analysis inducated the generation of micropollutant oxidation by-products, which aggravate the quality of treated aqueous solutions.
Źródło:
Journal of Ecological Engineering; 2017, 18, 4; 123-129
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ultrafiltracyjne doczyszczanie odpływów z oczyszczalni ścieków komunalnych
The municipal sewage treatment plant effluent polishing in ultrafiltration
Autorzy:
Dudziak, M.
Kudlek, E.
Łaskawiec, E.
Felis, E.
Kowalska, K.
Garbaczewski, L.
Powiązania:
https://bibliotekanauki.pl/articles/400811.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
ultrafiltracja
oczyszczanie ścieków
efektywność procesu
ultrafiltration
wastewater treatment
efficiency of the process
Opis:
Odpływ z oczyszczalni ścieków komunalnych poddano porównawczo oczyszczaniu w procesie ultrafiltracji z wykorzystaniem membrany ceramicznej i polimerowej. Filtrację prowadzono w systemie cross-flow w warunkach ciśnienia transmembranowego procesu 0,1 MPa – membrana ceramiczna i 0,2 MPa – membrana polimerowa oraz w temperaturze 20°C. Skuteczność procesu oceniono wykonując różne analizy fizyko-chemiczne (m.in. pH, mętność, barwa, absorbancja, OWO i indeks fenolowy). Włączono również ocenę toksykologiczną (stosując jako organizm wskaźnikowy bakterie bioluminescencyjne Aliivibrio fischeri) oraz mikrobiologiczną badanych próbek wodnych. Podczas filtracji badano wydajność hydrauliczną membran. Określono, że skuteczność procesu zależy od warunków prowadzenia filtracji membranowej, przy czym lepsze efekty usunięcia zanieczyszczeń organicznych odnotowano w przypadku membrany polimerowej niż ceramicznej. Jednak membrana polimerowa w porównaniu do membrany ceramicznej była bardziej podatna na zjawisko blokowania porów powodujące obniżenie wydajności hydraulicznej. Bez względu na rodzaj membrany permeaty nie były toksyczne jak i nie zawierały mikroorganizmów.
The effluent from the municipal sewage treatment plant was comparatively treated in the ultrafiltration process using ceramic and polymer membranes. Filtration was carried out in the cross-flow system under the conditions of the transmembrane process pressure of 0.1 MPa in the case of the ceramic membrane and 0.2 MPa with the polymer membrane, at a temperature of 20°C. The effectiveness of the process has been assessed by means of various physical and chemical analyses (pH, turbidity, color, absorbance, TOC and phenol index). The toxicological assessment (by applying the bioluminescent bacteria Aliivibrio fischeri as an indicator organism) and microbiological assessment of tested samples were included. The hydraulic efficiency of membranes was studied during filtration. Is was specified that the efficiency of the process depends on the conditions of membrane filtration, wherein the better effects of the removal of organic pollutants have been noted in the case of polymer membrane than with the ceramic membrane. However, the polymer membrane, in comparison to the ceramic membrane, was more susceptible to pore blocking, which caused the reduction of hydraulic efficiency. Regardless of the type of membrane, the permeates were not toxic and did not contain microorganisms.
Źródło:
Inżynieria Ekologiczna; 2017, 18, 4; 40-46
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elimination of Bisphenol A from Wastewater through Membrane Filtration Processes
Autorzy:
Dudziak, M.
Kudlek, E.
Łaskawiec, E.
Felis, E.
Kowalska, K.
Garbaczewski, L.
Powiązania:
https://bibliotekanauki.pl/articles/123664.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
wastewater treatment
bisphenol A
ultrafiltration
reverse osmosis
complex purification process
Opis:
New priorities for the environment have resulted in a reassessment of modern technology for treatment of urban wastewater. Urban wastewater treatment mainly involves the elimination or reduction of anthropogenic organic micropollutants in the aquatic environment. In this paper, the effectiveness of bisphenol A elimination from wastewater, after biological treatment, through a complex ultrafiltration/reverse osmosis purification process was evaluated. The effectiveness of the wastewater treatment process in the tested system was also evaluated with a number of other physical and chemical analyses for pH, turbidity, colour, absorbance, TOC, phenol index, conductivity and the concentration of selected heavy metals. Within this study, the change in the hydraulic performance of the membranes was also investigated. The effectiveness of the reduction of bisphenol A concentrations during the process of ultrafiltration was small, due to the significant difference between the size of the pores of the membrane and the size of eliminated micropollutants. In the process of reverse osmosis, the wastewater treatment system reported that the concentration of bisphenol A was reduced by 68%. In the tested treatment system, the ultrafiltration/reverse osmosis completely removed colour, lead and chromium. Other contaminants were eliminated by more than 31%. In both membrane processes, there was evidence that the membrane pores were blocked, but this occurred to a greater extent during the process of reverse osmosis.
Źródło:
Journal of Ecological Engineering; 2018, 19, 1; 69-74
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oznaczanie wybranych niesteroidowych leków przeciwbólowych i przeciwzapalnych w środowisku wodnym
Determination of selected nonsteroidal anti-inflammatory drugs in the aquatic environment
Autorzy:
Kudlek, E.
Bohdziewicz, J.
Dudziak, M.
Grübel, K.
Powiązania:
https://bibliotekanauki.pl/articles/960235.pdf
Data publikacji:
2015
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
diklofenak
ibuprofen
ekstrakcja SPE
GC-MS (EI)
diclofenac
SPE
Opis:
Obecność związków farmaceutycznych w środowisku wodnym wymusza opracowanie skutecznej metody ich monitoringu. W pracy przedstawiono opracowany sposób oznaczenia wybranych związków farmaceutycznych z grupy niesteroidowych leków przeciwbólowych i przeciwzapalnych, tj. ibuprofenu i diklofenaku. Do wydzielenia analitów zastosowano ekstrakcję do fazy stałej (SPE), a do analizy jakościowo-ilościową chromatografię gazową sprzężoną z detektorem masowym (GC-MS). Opracowana procedura analityczna umożliwia rozdział i oznaczenie ilościowe mieszaniny związków farmaceutycznych z zadowalającą powtarzalnością i dokładnością. Wyznaczone wartości stopni odzysku dają możliwość pełnej kontroli ilościowego oznaczenia badanych farmaceutyków w próbkach wodnych. Powyższa metoda może znaleźć zastosowanie do kontroli analitycznej przebiegu procesów uzdatniania wód naturalnych i doczyszczania ścieków pod kątem eliminacji związków farmaceutycznych.
The presence of pharmaceutical compounds in the aquatic environment requires the development of an effective monitoring method. The paper presents the developed procedure of determination of pharmaceutical compounds selected from the group of nonsteroidal anti-inflammatory drugs - ibuprofen and diclofenac. To isolate selected compounds from the tested water the solid phase extraction (SPE) was employed. The quantitative and qualitative analysis was carried out by gas chromatography coupled with mass spectrometry (GC-MS). Described analytical procedure allows to separate and quantificat pharmaceutical mixtures with a satisfactory reproducibility and accuracy. The values of the recovery degree confer the possibility of the complete quantitative control of tested pharmaceuticals in water samples. The described method can be used to control the analytical processes of natural water purification and wastewater treatment from pharmaceutical compounds.
Źródło:
Proceedings of ECOpole; 2015, 9, 2; 641-648
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Toksykologiczna ocena procesu fotolitycznego oczyszczania strumieni wodnych zawierających wybrane substancje priorytetowe oraz związki farmaceutyczne
Toxicological evaluation of treatment process of water streams containing selected priority substances and pharmaceutical compounds
Autorzy:
Bohdziewicz, J.
Dudziak, M.
Kudlek, E.
Kamińska, G.
Powiązania:
https://bibliotekanauki.pl/articles/2073077.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
mikrozanieczyszczenia organiczne
fotoliza
test Microtox
organic micropollutants
photolysis
Microtox test
Opis:
W pracy zaproponowano zastosowanie testu Microtox® do oceny toksykologicznej wody zawierającej wybrane substancje priorytetowe i związki farmaceutyczne, poddanej procesowi fotolizy. Wykazano, że w trakcie napromieniowania UV dochodzi do generowania toksycznych ubocznych produktów rozkładu związków pogarszających jakość oczyszczanej wody. Ponadto stwierdzono, że stopień rozkładu badanych mikrozanieczyszczeń w procesie fotolizy zależał od rodzaju związku i czasu naświetlania.
The use of the Microtox® test for toxicological evaluation of water samples containing selected priority substances and pharmaceutical compounds subjected to the photolysis process is proposed in the paper. The results indicated that during UV irradiation toxic byproducts of their reduction were generated. Those products deteriorated the quality of treated water. It was also found that a degree of removal of tested compounds depended on the compound nature and time of UV irradiation.
Źródło:
Inżynieria i Aparatura Chemiczna; 2015, 3; 67--68
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effectivness of Removal of Selected Biologically Active Micropollutants in Nanofiltration
Ocena skuteczności usuwania wybranych substancji aktywnych biologicznie w procesie nanofiltracji
Autorzy:
Kamińska, G.
Dudziak, M.
Bohdziewicz, J.
Kudlek, E.
Powiązania:
https://bibliotekanauki.pl/articles/389054.pdf
Data publikacji:
2016
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
biologically active compounds
nanofiltration
związki aktywne biologicznie
nanofiltracja
Opis:
This study addressed the removal efficiency of five different compounds classified as biologically active compounds ie benzo(a)pyrene (BaP), anthracene (ANT), diclofenac (DCL), pentachlorophenol (PCP), octylphenol (OP) in nanofiltration. They were removed from deionized water solution (500 µg/dm3) and comparatively from synthetic and municipal effluent. It was found that the efficiency of the nanofiltration depends on significantly both on type of membrane and the environmental matrix and physic-chemical properties of the compounds contained in the treated feed. The highest retention was observed for benzo(a)pyrene removed from deionized water. In this case, the retention of BaP varied from 99.82% to 99.94%. For other compounds (excluding octylphenol) we observed an inverse trend, higher retention degrees were obtained when the synthetic or real effluent were filtered. This study documented a complex mechanism of separation of low molecular weight organic micropollutants in nanofiltration, which could be a result of intermolecular interactions, sieve effect and adsorption. In addition, in the last part we compare our experimental data with predicted retention coefficients, which were computed from models for predicting retention of micropollutants in nanofiltration.
W ramach pracy podjęto badania nad oceną skuteczności usuwania pięciu różnych związków nale żących do grupy substancji aktywnych biologicznie, tj. benzo(a)piren (BaP), antracen (ANT), diklofenak Effectivness of Removal of Selected Biologically Active Micropollutants in Nanofiltration 197 (DCL), pentachlorofenol (PCP) i oktylofenol (OP) w procesie nanofiltracji. Przedmiotem badań były modelowe roztwory tych substancji o stężeniu 500 µg/dm3 wykonane na bazie wody zdejonizowanej. Uzyskane wyniki badań porównano pod kątem skuteczności usuwania wybranych związków z syntetycznych i rzeczywistych odpływów z komunalnej oczyszczalni ścieków. Wykazano, że na skuteczność procesu nanofiltracji istotny wpływ ma rodzaj membrany nanofiltracyjnej, właściwości fizykochemiczne usuwanych związków, jak również rodzaj matrycy środowiskowej poddawanej oczyszczaniu. Najwyższą efektywność usuwania zaobserwowano dla benzopirenu w trakcie nanofiltracji wody zdejonizowanej. Współczynniki retencji wynosiły wówczas od 99,82% do 99,94%, co oznacza praktycznie jego całkowite usunięcie. Z kolei dla pozostałych związków z wyjątkiem oktylofenolu zaobserwowano odwrotną tendencję, wyższe współczynniki retencji uzyskano, gdy filtrowanym medium były ścieki syntetyczne lub rzeczywiste. Przeprowadzone badania udokumentowa ły złożony mechanizm separacji małocząsteczkowych mikrozanieczyszczeń organicznych w procesie nanofiltracji wynikający m.in. z oddziaływań międzycząsteczkowych, efektu sitowego, jak i adsorpcji. Dodatkowo, w ostatniej części pracy porównano uzyskane dane doświadczalne z przewidywanymi współczynnikami retencji, które zostały obliczone z modeli dotyczących przewidywania retencji mikrozanieczyszczeń w procesie nanofiltracji.
Źródło:
Ecological Chemistry and Engineering. A; 2016, 23, 2; 185-198
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Usuwanie antropogenicznych mikrozanieczyszczeń organicznych z różnych strumieni wodnych w procesie sekwencyjnym FK/UF/NF
Removal of antropogenic organic micropollutants from different water streams in the FK/UF/NF sequential system
Autorzy:
Kudlek, E.
Dudziak, M.
Bohdziewicz, J.
Kamińska, G.
Powiązania:
https://bibliotekanauki.pl/articles/399864.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
mikrozanieczyszczenia organiczne
środowisko wodne
układ sekwencyjny
fotokataliza
ultrafiltracja
nanofiltracja
organic micropollutants
water environment
sequential system
photocatalysis
ultrafiltration
nanofiltration
Opis:
Znaczna liczba mikrozanieczyszczeń organicznych pochodzenia antropogenicznego zaliczana jest do związków trudno- lub niebiodegradowalnych, mogących negatywnie oddziaływać na organizmy żywe, w tym również na zdrowie człowieka. Za główne źródło tego rodzaju zanieczyszczeń uznawane są ścieki bytowo-gospodarcze oraz ścieki z różnych gałęzi przemysłu. Celem pojętych badań było opracowanie metody pozwalającej na usunięcie z różnych strumieni wodnych wybranych mikrozanieczyszczeń tj. diklofenaku, oktylofenolu, antracenu oraz bezno[a]pirenu w oparciu o zawansowane procesy utleniania oraz techniki filtracji membranowej. Badania prowadzono na roztworach sporządzonych na bazie wody zdejonizowanej oraz modelowych i rzeczywistych ściekach zawierających mikrozanieczyszczenia o stężeniu 0,5 mg/dm3. Zastosowano fotokatalityczne utlenianie w obecności TiO2 prowadzone w reaktorze porcjowym wyposażonym w lampę UV o mocy 150 W. Uzyskane roztwóry poprocesowe poddano procesowi ultrafiltracji mającej na celu odseparowanie cząsteczek katalizatora jak i zatrzymanie wysokocząsteczkowych związków organicznych wchodzących w skład oczyszczanych strumieni wodnych. Proces realizowano w układzie filtracji jednokierunkowej przy ciśnieniu transmembranowym wynoszącym 0,2 MPa. Wykonana analiza chromatograficzna mająca na celu określenie stopnia usunięcia badanych mikrozanieczyszczeń w roztworach podprocesowych wskazała na ich niecałkowity rozkład w procesie fotokatalizy oraz na generowanie znacznej liczby ubocznych produktów ich utleniania. W celu ich kompletnej eliminacji zastosowano drugi etap filtracji membranowej przy użyciu membrany nanofiltracyjnej. Zaproponowany układ łączący fotokatalizę z dwustopniową filtracją membranową pozwolił na ponad 91% usunięcie mikrozanieczyszczeń z roztworów wodnych sporządzonych na bazie wody zdejonizowanej oraz na całkowite usunięcie związków oraz ubocznych produktów ich utleniania ze ścieków modelowych jak i rzeczywistych.
A significant number of anthropogenic organic micropollutants are classified as hardly- or non-biodegradable compounds, which may adversely affect the living organisms, including human health. Municipal wastewater and wastewater from various industry sectors are considered as the main source of this type of pollutants. The aim of the conducted study was to develop a method for the removal of selected micropollutants such as diclofenac, octylphenol, anthracene and benzo[a]pyrene from various water streams, based on advanced oxidation processes and membrane filtration techniques. The research was carried out on solutions prepared on the basis of deionised water as well as a model and actual effluent from a mechanical-biological wastewater treatment line. The concentration of micropollutions was 0.5 mg/dm3. Photocatalytic oxidation was applied in the presence of TiO2 in a batch reactor equipped with a 150 W UV lamp. The post-processing solutions ware subjected to the ultrafiltration process, which allowed for the separation of catalyst particles and retention of high molecular weight organic compounds occurring in the treated water streams. The membrane filtration process was operated in a dead-end mode at a transmembrane pressure of 0.2 MPa. For their complete elimination, the second stage of membrane filtration using a nanofiltration membrane was applied. The chromatographic analysis, performed to determine the removal degree of tested micropollutants in the post-processing solutions, indicated their incomplete decomposition in the photocatalysis process and the generation of a significant number of their oxidation by-products. The proposed sequential system that combines photocatalysis with two-stage membrane filtration, allowed for over 91% removal of micropollutants from water solutions prepared on the basis of deionised water as well as for a complete removal of the compounds and their oxidation by-products from model and actual wastewater effluents.
Źródło:
Inżynieria Ekologiczna; 2017, 18, 4; 116-124
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena wpływu systemu cyrkulacji na poziom stężeń mikrozanieczyszczeń w układzie oczyszczania wody basenowej
The impact of the circulation system on the concentration levels of micropollutants in the swimming pool water treatment system
Autorzy:
Lempart, A.
Kudlek, E.
Dudziak, M.
Szyguła, A.
Powiązania:
https://bibliotekanauki.pl/articles/399926.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
system oczyszczania
woda basenowa
cyrkulacja wody
PPCPs
mikrozanieczyszczenia
pool water
treatment system
water circulation
micropollutants
Opis:
Każda instalacja basenowa powinna zapewniać prawidłową i stałą cyrkulację wody w systemie obiegu zamkniętego, która umożliwia przedłużenie czasu całkowitej wymiany wody nawet do 1 roku. Praca takiego systemu może jednak potencjalnie powodować podwyższenie stężenia małocząsteczkowych mikrozanieczyszczeń w układzie oczyszczania wody basenowej. Celem niniejszej pracy jest potwierdzenie lub odrzucenie niniejszej tezy. W ramach badań wstępnych przeprowadzono analizę zawartości substancji organicznych i nieorganicznych w wodzie basenowej na podstawie wskaźników ogólnych takich jak OWO, absorbancja UV254 i przewodność właściwa. W zasadniczym etapie badań, próbki wody basenowej pobierane z czterech różnych punktów instalacji zostały poddane analizie chromatograficznej w celu oznaczenia małocząsteczkowych mikrozanieczyszczeń organicznych. Badaniu poddano także wodę wodociągową stosowaną do napełnienia niecki i regularnego uzupełniania strat objętości. Badanie to miało na celu wykluczenie wody wodociągowej jako potencjalnie możliwego źródła pochodzenia zanieczyszczeń w wodzie basenowej. Przeprowadzone badania wstępne wykazały niemal dwukrotny wzrost zawartości ogólnego węgla organicznego oraz absorbancji UV254 po sześciu miesiącach, co niewątpliwie świadczy o możliwości gromadzenia się zanieczyszczeń organicznych w systemach cyrkulacji wody basenowej. Tego zjawiska nie zaobserwowano w przypadku związków nieorganicznych. W wyniku analiz chromatograficznych w wodzie basenowej oznaczono farmaceutyki i pozostałości kosmetyków. Stwierdzono, że w układzie oczyszczania wody basenowej miejscem największego gromadzenia się farmaceutyków jest zbiornik przelewowy, a pozostałości kosmetyków niecka basenowa. Na omawiane zjawisko ma wpływ czas trwania filtrocyklu.
Each pool installation should ensure proper and constant circulation of water in a closed circuit system. However, the operation of such a system can potentially cause the accumulation of small -molecule micropollutants in the pool water treatment system. The aim of this work is to confirm or reject this argument. As part of preliminary tests, the content of organic and inorganic substances in swimming pool water was analyzed based on general indicators such as TOC, UV254 absorbance and conductivity. In the main stage of the research, pool water samples collected from four different points of the swimming pool installation were subjected to chromatographic analysis to determine the small-molecule micropollutants. The tap water used to fill the basin and regular replenishment of volume losses was also tested. This study was intended to exclude the tap water as a potential source of contamination in the pool water. Preliminary studies have shown almost a two-fold increase in the total organic carbon content and absorbance UV254 at the turn of six months, which undoubtedly indicates the accumulation of organic pollutants in pool water circulation systems. It was not observed in the case of inorganic compounds. As a result of the chromatographic analyzes of the pool water, the content of pharmaceuticals and personal care product was determined. It was found that the compensation tank is the place of the highest accumulation of the tested pharmaceuticals in the pool water treatment system , while the cosmetics component accumulated in the pool basin to the greatest degree. It was affected by the duration of the filter cycle.
Źródło:
Inżynieria Ekologiczna; 2018, 19, 2; 23-31
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Skuteczność usuwania wybrancyh substancji aktywnych biologicznie podczas mechaniczno-biologicznego oczyszczania ścieków
Removal of biologically active substances during mechanical-biological wastewater treatment
Autorzy:
Kamińska, G.
Kudlek, E.
Dudziak, M.
Bohdziewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/950002.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
substancje aktywne biologicznie
oczyszczanie ścieków
eliminacja mikrozanieczyszczeń
priority emerging micropollutants
wastewater treatment
Opis:
W pracy przedstawiono wyniki monitoringu stężeń wybranych mikrozanieczyszczeń organicznych (antracen, benzo[a]piren, oktylofenol, nonylofenol, karbamazepina) w ściekach surowych, wstępnie oczyszczonych na stopniu mechanicznym oraz w odpływie odprowadzanym do środowiska. Obiektem badań były 3 komunalne oczyszczalnie ścieków zlokalizowane w województwie śląskim. Procedura oznaczenia związków obejmowała wydzielenie badanych substancji z próbek ścieków za pomocą ekstrakcji do fazy stałej, a następnie analizę chromatograficzną GC-MS. Przeprowadzone badania pozwoliły również ocenić skuteczność ich usuwania w trakcie konwencjonalnego oczyszczania ścieków. Spośród badanych substancji największe stężenia w ściekach surowych odnotowano dla antracenu i benzo[a]pirenu, natomiast zawartość nonylofenolu i oktylofenolu była około 15 krotnie niższa. Tendencję tą zaobserwowano dla wszystkich trzech badanych oczyszczalni. Stwierdzono również, że w ściekach z oczyszczalni o największej przepustowości zawartość mikrozanieczyszczeń była około 2 razy wiesza w stosunku do ścieków pobieranych z mniejszych obiektów. Skuteczność usuwania badanych związków podczas mechaniczno-biologicznego oczyszczania ścieków kształtowała się w zakresie od ponad 17 do 100%.
This study presents the results of monitoring some of the priority emerging substances (anthracene, benzo[a]pyrene, octylphenol, nonylphenol) in raw, primary treated and secondary treated wastewater from 3 WWTPs located in Silesia. The assay procedure of the compounds included the separation of substances from sewage samples by solid phase extraction and chromatographic analysis with GC-MS. Based on calculated concentration of given compounds, their total removal degree was determined. Among studied compounds the highest concentration in raw sewage was reported for anthracene and benzo[a]pyrene, while concentration of nonylphenol and octylphenol was 15 times lower. This trend was observed for all three studied WWTPs. It was also found that wastewater from the WWTPs of highest capacity was about 2 times higher in relation to the wastewater collected from smaller plants. The total removal efficiency of the studied compounds during two stage treatment was in the range of 17.5 to 100%.
Źródło:
Inżynieria Ekologiczna; 2016, 50; 201-209
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Presence of Compounds from the Personal Care Products Group in Swimming Pool Water
Autorzy:
Lempart, A.
Kudlek, E.
Lempart, M.
Dudziak, M
Powiązania:
https://bibliotekanauki.pl/articles/123464.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
swimming pools
personal care products
cosmetics
micropollutants
parabens
UV filters
Opis:
The global production of several thousands of Personal Care Products (PCPs) every year makes the release of PCPs to the environment an unavoidable by-product of a modernized lifestyle. Multiple studies have detected PCPs worldwide in various aquatic environments, including swimming pools. In the presented work, the concentrations of three selected compounds from the PCPs group were examined in 15 swimming pools with different functions. The aim of the study was to show the influence of various factors on the concentration levels of selected micropollutants. Two UV filters: BP-3 (oxybenzone), BP-8 (dioxybenzone) and one antioxidant BTH (dibutylhydroxytoluene) were selected for the research. The extraction of micropollutants from the swimming pool water matrix was carried out by Solid Phase Extraction (SPE). The extracts were analyzed using a gas chromatograph (GC) coupled to the mass detector (MS). BHT was the most common compound. Its concentration ranged from 3.8 ng/L to 5.5 ng/L. The most rarely occurring compound was BP-3. The concentration of this compound varied the most, from 18.5 ng/L to 1178.6 ng/L. BP-8 was present in 10 from 15 tested pools at the concentration level of 49.9–226.9 ng/L. The frequency of occurrence characterizing different micropollutants from PCPs group was higher in recreational pools than in sports pools. It was also observed that the applied water treatment technology may affect the presence of Personal Care Products in the swimming pool water. No impact of basic water quality parameters on the levels of tested pharmaceuticals has been shown in this research.
Źródło:
Journal of Ecological Engineering; 2018, 19, 3; 29-37
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowe sposoby otrzymywania surowic antyglobulinowych przydatnych w serodiagnostyce
The new methods of obtaining of the antiglobulin sera used in serodiagnostocs
Autorzy:
Dudziak, Z.
Feluś, E.
Panek, G.
Szaflarski, J.
Powiązania:
https://bibliotekanauki.pl/articles/2189768.pdf
Data publikacji:
1970
Wydawca:
Polskie Towarzystwo Diagnostyki Laboratoryjnej
Źródło:
Diagnostyka Laboratoryjna; 1970, 06, 2; 117-125
0867-4043
Pojawia się w:
Diagnostyka Laboratoryjna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Swerodiagnostyczna przydatność reumatoidalnego lateksu krajowego w świetle odczynu Waaler-Rosea
Serodiagnosticheskaja prigodnost' revmatoidal'nogo lateksa otechestvennogo proizvodstva po otnosheniju k reakcii Vaalera-Roza
Suitableness of the Polish make rheumatoid latex for sero-diagnostic purposes, in the light of the Waaler-Rose test
Autorzy:
Dudziak, Z.
Kośmiderski, S.
Panek, G.
Feluś, E.
Powiązania:
https://bibliotekanauki.pl/articles/2191236.pdf
Data publikacji:
1967
Wydawca:
Polskie Towarzystwo Diagnostyki Laboratoryjnej
Źródło:
Diagnostyka Laboratoryjna; 1967, 03, 4; 311-315
0867-4043
Pojawia się w:
Diagnostyka Laboratoryjna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The use of Membrane Techniques in Swimming Pool Water Treatment
Autorzy:
Łaskawiec, E.
Madej, M.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/952481.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
pressure membrane processes
ultrafiltration
nanofiltration
toxicological assessment
Opis:
The paper has determined the suitability of membrane processes (UF ultrafiltration, UF, and nanofiltration, NF) for the purification of waste streams, so-called backwash water, obtained from washing filtration beds in a swimming pool water system. The backwash water samples were taken from the circuits located in two indoor facilities with a different purpose of the basins. Moreover, the samples were characterized by varying quality, as described by selected physicochemical parameters (such as turbidity and ultraviolet absorbance UV254). Commercial membranes were used for the tests. The transport-separation properties of the membranes were determined based on the volumetric flux of the permeate. In addition, backwash water samples before and after the membrane process were subjected to toxicological assessment using the Microtox® screening test. The performed processes contributed to a significant reduction in turbidity and the value of UV254 ultraviolet absorbance, both in the ultrafiltration and nanofiltration processes. Whereas, significant differences in transport properties were noted within individual processes. A great influence of backwash water quality, including physicochemical parameters, on the course and results of the membrane filtration processes was demonstrated. In all of the nanofiltration cycles carried out, the removal of the toxic properties of the backwash water with respect to bacteria in the Microtox® test was found. Nevertheless, samples with high values of resultant physicochemical parameters after the ultrafiltration process were still characterized by high toxicity. Pressure membrane processes show high effectiveness in the removal of contaminants from backwash water. However, it is necessary to introduce supporting processes aimed at reducing membrane pore blocking by deposits and organic compounds, and in the case of ultrafiltration, assuring the safety of the purified stream in terms of the toxicological effect.
Źródło:
Journal of Ecological Engineering; 2017, 18, 4; 130-136
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Interpretacja odczynów aglutynacyjnych z lateksem opłaszczonym ludzką gamma-globuliną G
Autorzy:
Dudziak, Z.
Kośmiderski, S.
Panek, G.
Feluś, E.
Hendryk, S.
Powiązania:
https://bibliotekanauki.pl/articles/2189254.pdf
Data publikacji:
1975
Wydawca:
Polskie Towarzystwo Diagnostyki Laboratoryjnej
Źródło:
Diagnostyka Laboratoryjna; 1975, 11, 5-6; 399-403
0867-4043
Pojawia się w:
Diagnostyka Laboratoryjna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Clustering of Staphylococcus aureus bovine mastitis strains from regions of Central-Eastern Poland based on their biochemical and genetic characteristics
Autorzy:
Puacz, E.
Ilczyszyn, W.M.
Kosecka, M.
Buda, A.
Dudziak, W.
Polakowska, K.
Panz, T.
Bialecka, A.
Kasprowicz, A.
Lisowski, A.
Krukowski, H.
Cuteri, V.
Miedzobrodzki, J.
Powiązania:
https://bibliotekanauki.pl/articles/31348.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Opis:
Staphylococcus aureus strains were isolated from mastitic milk of cows with infected mammary glands. The animals were living in 12 different farms near Lublin, in Central-Eastern Poland. A biochemical identification method based on enzymatic assay was performed, followed by haemolytic and proteolytic tests. PCR-RFLP targeted on the gap gene allowed the genetic identification of strains at the species level and verified phenotypic identification results. A molecular typing method using triplex PCR was performed to recognize the genetic similarity of the analyzed strains. DNA microar-ray hybridization (StaphyType, Alere Technologies) was used for detection of antibiotic resistance and virulence associated markers. The results obtained indicate high genetic similarity in strains isolated from the same sites. High genetic similarities were also detected between strains isolated from cows from different farms of the same region. A slightly lower similarity was noted however, in strains from various regions indicating that the strains are herd specific and that the cow's infections caused by S. aureus were of a clonal character. In 21 representative isolates selected for DNA-microarray testing, only fosfomycin (fosB) and penicillin resistance markers (blaZ, blaI, blaR) were detected. The presence of genes coding for haemolysins (lukF, lukS, hlgA, hla, hld, hlb), proteases (aur, sspA, sspB, sspP), enterotoxins (entA, entD, entG, entI, entJ, entM, entN, entO, entR entU, egc-cluster), adhesins (icaA, icaC, icaD, bbp, clfA, clfB, fib, fnbA, map, vwb) or immune evasion proteins (scn, chp, sak) was common and, with exceptions, matched triplex PCR-defined clusters.
Źródło:
Polish Journal of Veterinary Sciences; 2015, 18, 2
1505-1773
Pojawia się w:
Polish Journal of Veterinary Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-59 z 59

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies