Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Chmielowski, A." wg kryterium: Autor


Tytuł:
The effect of selected hydromorphological parameters on the state of aquatic vegetation in the Chechło river
Autorzy:
Bedla, D.
Misztal, A.
Krużel, J.
Chmielowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/101313.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
macrophytes
hydromorphological parameters
flowing water
Opis:
The development of vegetation in lotic waters, including macrophytes, is determined by diverse factors, including bottom substrate, flow velocity, and the width and depth of a channel, which are hydromorphological parameters. Macrophytes are higher plants of terrestrial origin which have undergone numerous adaptations enabling them to live in water (Stańczykowska, 1975). The aim of the study was to assess the effect of selected hydromorphological parameters of a watercourse on the species composition of macrophytes. The subject of the study was the Chechło River, a left tributary of the Vistula. The study was carried out in two adjacent segments of the watercourse, according to guidelines in the Macrophyte Index for Rivers (MMOR) and elements of the River Habitat Survey (RHS). The study revealed similar hydromorphological conditions in the two segments of the river, and the variation in the species composition of macrophytes in the two segments seems to be determined by other factors which were not the subject of the study. Among these, significant factors might include regulation works or the high water levels in the Chechło resulting from the construction of an impoundment. The plants identified in the two segments of the watercourse are species occurring commonly in Poland, preferring eutrophic waters and having a wide ecological tolerance.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2016, III/1; 705-714
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ ścieków pochodzących ze zbiorników bezodpływowych na zmienność stężeń zanieczyszczeń w ściekach poddawanych procesom oczyszczania
Influence of sewage from septic tanks on the variability concentration of pollutants in sewage undergoing purification processes
Autorzy:
Bugajski, P.
Chmielowski, K.
Cupak, A.
Wąsik, E.
Powiązania:
https://bibliotekanauki.pl/articles/101205.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
ścieki
zbiornik na nieczystości ciekłe
korelacja
zanieczyszczenia
sewage
septic tank
correlation
pollutants
Opis:
Celem pracy było określenie wpływu udziału ścieków pochodzących ze zbiorników na nieczystości płynne na zmienność stężeń zanieczyszczeń w mieszaninie ścieków poddawanych procesowi oczyszczania w zbiorczej oczyszczalni ścieków. W pracy pomiarem objęto dobową ilość ścieków dopływających oraz dowożonych taborem asenizacyjnym i określono udział procentowy ilość ścieków dowożonych w stosunku do całości ścieków poddawanych procesowi oczyszczania. W okresie 5-cio letnich badań pobrano i poddano analizie 20 próbek ścieków, w których wykonano oznaczenia wskaźników: BZT5, ChZT oraz zawiesina ogólna. Po wykonaniu analizy statystycznej stwierdzono, że wraz ze wzrostem udziału ścieków dowożonych o 1% wzrasta wartość BZT5 o 14,6 mgO2·dm-3, wzrasta wartość ChZT o 40,2 mgO2·dm-3 oraz wzrasta stężenie zawiesiny ogólnej o 21,4 mg·dm-3 w ogólnej mieszaninie ścieków poddawanych procesowi oczyszczania.
The aim of the study was to determine the influence of the percentage of sewage from septic tanks to the variability of pollutant concentrations in the mixture of sewage undergoing treatment process in the collective sewage treatment plant. The study involved measuring the daily amount of wastewater influent and from septic tanks and determined the percentage of the amount of sewage from septic tanks in relation to the total wastewater being purified. During the 5-year study collected and analyzed 20 samples of sewage, which were made markings indicators: BOD5, COD and total suspension. After the statistical analysis, it was found that with the increase of the share of sewage from septic tanks by 1% increased the value of BOD5 14.6 mgO2·dm-3, increases the value of COD 40.2 mgO2·dm-3 and increases the concentration of total suspension of 21,4 mg·dm-3 in the total mixture of the waste water being purified.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2016, II/2; 517-526
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowanie parametrów przepływów w strumieniowym układzie wentylacyjnym napędzanym kolektorem słonecznym
Modelling of the parameters of flow in a sun collector-driven jet pump ventilation system
Autorzy:
Chmielowski, A.
Gedymin, M.
Powiązania:
https://bibliotekanauki.pl/articles/291237.pdf
Data publikacji:
2008
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
solarne urządzenie wentylacyjne
kolektor słoneczny
strumienica
parametry przepływu
ventilation system
sun collector
jet pump
Opis:
Analiza problemu wentylacji naturalnej doprowadziła do rozwiązania kojarzącego strumienicę z kolektorem słonecznym jako źródłem energii napędowej. Połączenie tych dwu urządzeń, prostych konstrukcyjnie lecz we wzajemnych relacjach tworzących specyficzne sprzężenia zwrotne, wymusiło opracowanie metody obliczania ich parametrów roboczych. Specyficzne warunki pracy spowodowały konieczność uzyskania części z nich doświadczalnie na odpowiednim modelu. Implementacja uzyskanych wyników w modelu matematycznym umożliwiła zastosowanie go do budowy modelu funkcjonalnego w skali 1:1. Zbudowany model, obsługując określoną grupę ptaków w kurniku laboratoryjnym, został zweryfikowany pozytywnie. Uzyskane charakterystyki robocze i utrzymywane warunki środowiskowe w pomieszczeniu z kurami są zadowalające.
The analysis of the problem of natural ventilation has resulted in a solution linking a jet pump with a sun collector as a source of driving energy. The combination of these two devices, constructionally simple but forming, due to their interrelations, specific feedback, has forced us to develop a method for calculating their operating parameters. Considering the specific operating conditions, some of them had to be determined experimentally, using a suitable model. The implementation of the results obtained in a mathematical model has made it possible to use it to build a 1:1 scale functional model. The model built, intended for a specified group of birds in a laboratory hen house, has been positively verified. The obtained operating characteristics and the maintained environmental conditions in the hen house are satisfactory.
Źródło:
Inżynieria Rolnicza; 2008, R. 12, nr 4(102), 4(102); 155-161
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ścieranie pazurów kur utrzymywanych w klatkach
Grinding of the claws of hens bred in the cages
Autorzy:
Chmielowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/884076.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Maszyn Rolniczych
Tematy:
utrzymanie zwierzat
utrzymanie klatkowe
klatki wzbogacone
innowacje
urzadzenia scierajace
kury
scieranie pazurow
Opis:
W artykule opisano badania nowego urządzenia realizującego wymaganą przez przepisy funkcję utrzymywania pazurów kur chowanych w klatkach w bezpiecznej dla nich długości. Opisano założenia do rozwiązania problemu, konstrukcję, metodę badań oraz uzyskane wyniki. Stwierdzono spełnienie przez urządzenie założonej funkcji zgodnie z wymaganiami.
In the article there were described the investigations of the new device realizing required by regulations a function of keeping the claws of hens bred in cages in length safe for them. There were described presumptions to solve the main problem, construction, method of investigations and obtained results. It was stated that the device has fulfilled assumed functions in accordance with the requirements.
Źródło:
Technika Rolnicza Ogrodnicza Leśna; 2012, 04
1732-1719
2719-4221
Pojawia się w:
Technika Rolnicza Ogrodnicza Leśna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza zmienności dopływu ścieków do oczyszczalni dla aglomeracji Dębica
Analysis of sewage inflow variability to a sewage treatment plant for the agglomeration of Dębica
Autorzy:
Chmielowski, K.
Bugajski, P.
Wąsik, E.
Cupak, A.
Powiązania:
https://bibliotekanauki.pl/articles/101536.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
ścieki bytowe
dopływ ścieków
oczyszczalnia ścieków
domestic sewage
hydraulic load
sewage treatment plant
Opis:
W pracy dokonano analizy zmienności dopływu ścieków do oczyszczalni w Dębicy. W tym celu określono podstawowe statystyki opisowe dotyczące dopływu ścieków do oczyszczalni: wartość średnia (Qdśr), mediana (Mo), wartość minimalna (Qdmin), wartość maksymalna (Qdmax), odchylenie standardowe, współczynnik zmienności (Vzm), rozstęp (Ro). Określono histogram liczby dopływów ścieków do oczyszczalni dla zadanych przedziałów obserwacji. Zestawiono szczegółowe dobowe dopływy ścieków surowych do oczyszczalni w Dębicy w latach 2019-2015 na tle wartości dopuszczalnej z pozwolenia wodno-prawnego oraz wartości średniej. Zestawiono średnie dobowe wartości przepływów ścieków dla poszczególnych miesięcy roku dla okresu 2009-2015. Dokonano zestawienia średnich dobowych przepływów ścieków w poszczególnych latach badanego okresu. Zestawiono średnie dobowe wartości przepływów ścieków w poszczególnych dniach tygodnia dla okresu 2009-2015. Ponadto pozyskano dane opadowe ze stacji w Tarnowie (najbliższa stacja opadowa od badanego obiektu) i na tej podstawie określono średnie wartości dobowego opadu atmosferycznego dla poszczególnych miesięcy w latach 2009-2015. Następnie dokonano podziału dób okresu badawczego ze względu na wielkość opadów atmosferycznych na 7 zasadniczych grup. Określono wpływ opadów atmosferycznych na ilość ścieków dopływających do badanego obiektu. Stwierdzono znaczący wpływ opadów atmosferycznych na dopływ ścieków do oczyszczalni w Dębicy.
The paper analyzes the variability of sewage inflow to a treatment plant in Dębica. For this purpose, the following basic descriptive statistics of the sewage inflow to the treatment plant were determined: mean value (Qdm), median (Mo), minimum value (Qdmin), maximum value (Qdmax), standard deviation, coefficient of variation (Vzm), range (Ro). Histogram of a number of sewage inflows to the treatment plant for the specified observation intervals was determined. Detailed diurnal raw sewage inflows to the treatment plant in Dębica were summarized for the period of 2009-2015 compared to the limit value specified by the water-legal permit and the to the mean value. Mean diurnal sewage flow values for individual months from the period of 2009-2015 were also summarized. Mean diurnal sewage flows in individual years of the studied period, as well as mean diurnal sewage flow values in each day of the week were compared. Moreover, runoff data were obtained from the Tarnów station (the nearest rainfall station to the studied facility) and on this basis mean values of diurnal precipitation for individual months in the period of 2009-2015 were determined. Subsequently, the days of the study period were divided into 7 major groups based on the amount of atmospheric precipitation. The effect of precipitation on the amount of sewage flowing into the studied facility was examined and it was found that the precipitation has a significant effect on the sewage inflow to the treatment plant in Dębica.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2016, II/2; 589-603
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of sewage susceptibility to biodegradation on an example of sewage treatment plant in Wodzisław Śląski
Autorzy:
Chmielowski, K.
Wąsik, E.
Operacz, A.
Bugajski, P.
Kaczor, G.
Jurik, L.
Powiązania:
https://bibliotekanauki.pl/articles/101267.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
sewage biodegradation
sewage composition
sewage treatment plant
Opis:
The paper presents an analysis of sewage susceptibility to biodegradation on an example of sewage treatment plant in Wodzisław Śląski in the Śląskie province. For this purpose, dependencies between selected indices of domestic sewage pollution were applied. Descriptive statistics of the respective indices rations COD/BOD5 , BOD5 /TN, BOD5 /TPwere presented. Moreover, an analysis was conducted on the composition of raw sewage flowing into the treatment plant, pre-treated sewage and sewage leaving the studied treatment plant. The analysis was carried out on the basis of three basic indices of sewage pollution (BOD5 , COD and total suspended solids) and two biogenic indices (total nitrogen and total phosphorus). Tests on the sewage composition were conducted in the years 2010-2015. Basic descriptive statistics were compiled for the values of the studied indices of sewage pollution and the obtained results were interpreted. On the basis of collected material it may be said that sewage reaching the treatment plant in Wodzisław Śląski revealed a good susceptibility to biodegradation, whereas the BOD5 /TN and BOD5 /TP ratios were below the optimum value.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2017, IV/1; 1427-1443
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efektywność pracy oczyszczalni ścieków w Kołaczycach
Operational efficiency of wastewater treatment plant in Kolaczyce
Autorzy:
Chmielowski, K.
Młyńska, A.
Młyński, D.
Powiązania:
https://bibliotekanauki.pl/articles/400312.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
oczyszczalnia ścieków
BZT5
ChZTCr
zawiesina ogólna
wastewater treatment plant
BOD5
CODCr
total suspended solids
Opis:
W artykule dokonano analizy efektywności pracy oczyszczalni ścieków w Kołaczycach na podstawie wyników badań fizykochemicznych ścieków surowych oraz ścieków oczyszczonych w latach 2010 – 2014. Przeanalizowano zmiany wartości trzech wskaźników zanieczyszczeń – BZT5, ChZTCr i zawiesiny ogólnej. Wyniki badań wskazują na to, iż oczyszczalnia funkcjonuje w sposób prawidłowy. Średnia wartość BZT5 w ściekach oczyszczonych wyniosła 10,9 mg O2 dm-3, ChZTCr – 71,0 mg O2 dm-3, zawiesiny ogólnej – 15,0 mgdm-3, a zatem wielkości te były mniejsze od dopuszczalnych wartości w ściekach odprowadzanych do odbiornika, które reguluje Rozporządzenie Ministra Środowiska z 2014 roku. O zadowalającej efektywności pracy obiektu świadczy również wysoka procentowa średnia redukcja każdego ze wskaźników zanieczyszczeń (dla BZT5 – 97,8%, dla ChZTCr – 93,7%, dla zawiesiny ogólnej – 97,6%), a także wartości współczynników niezawodności oczyszczalni (WNBZT5= 0,44, WNChZTCr= 0,57, WNzaw.og.= 0,43).
In the article the analysis of operational efficiency Wastewater Treatment Plant in Kolaczyce was performed based on the physico-chemical research results of raw sewage and treated sewage between 2010 and 2014. The analysis of values changing of three pollutants indicators – BOD5, CODCr and total suspended solids was performed. Research results indicate that treatment plant works properly. Average value of BOD5 in treated sewage was 10.9 mg O2 dm-3, CODCr – 71.0 mg O2 dm-3, total suspended solids – 15.0 mg dm-3 so these values were lower than permissible pollutants content in sewage discharged to the collector which is determined by the Polish Ministry of Environmental Regulation of 2014. On satisfactory operational efficiency treatment plant indicates also high percentage reduction of each pollutants indicators (for BOD5 – 97.8%, for ChZTCr – 93.7%, for total suspended solids – 97.6%) and treatment plant reliability factors (WNBZT5= 0.44, WNChZTCr= 0.57, WNzaw.og.= 0.43).
Źródło:
Inżynieria Ekologiczna; 2015, 45; 44-50
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Filtry piaskowe o przepływie pionowym jako drugi stopień oczyszczania małych ilości ścieków bytowych
Vertical flow sand filters as the second step of the small amount of living sewage treatment
Autorzy:
Chmielowski, K.
Walega, A.
Powiązania:
https://bibliotekanauki.pl/articles/61463.pdf
Data publikacji:
2009
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
oczyszczalnie sciekow
oczyszczalnie przydomowe
scieki
przeplyw pionowy
filtry piaskowe
rozwiazania konstrukcyjne
warstwy filtracyjne
uziarnienie
blony biologiczne
skutecznosc oczyszczania
Opis:
Celem artykułu było gruntowne przedstawienie rozwiązań konstrukcyjnych stosowanych przy budowie filtrów piaskowych o przepływie pionowym, opisanie materiałów stosowanych do ich budowy oraz przedstawienie skuteczności ich działania. Filtry piaskowe stosowane są głównie jako drugi stopień oczyszczania ścieków po osadnikach gnilnych lub osadnikach Imhoffa, jak również jako trzeci stopień po biologicznych procesach oczyszczania, gdy wymagany jest odpływ ustabilizowany i o wysokiej jakości. Filtry piaskowe zalecane są do oczyszczania ścieków z pojedynczych domów oraz z ich zespołów, jak również mogą być stosowane w większych oczyszczalniach ścieków z obiektów użyteczności publicznej i usługowej. W artykule przedstawiono dodatkowo skuteczności oczyszczania ścieków w filtrach piaskowych o przepływie pionowym. Artykuł kończy się podsumowaniem i wnioskami gdzie stwierdza się, że filtry piaskowe o przepływie pionowy stanowią bardzo dobre rozwiązanie przy budowie przydomowych oczyszczalni ścieków, na terenach gdzie nie można zastosować kanalizacji zbiorczej. Ponadto skuteczność oczyszczania ścieków w tych obiektach jest bardzo wysoka.
The article presents the thorough description of the vertical flow sand filters. The construction of sand filters was also presented and materials used for building filters were described. In the next part, capacities of sewage treatment in the vertical flow sand filters were presented. Vertical flow sand filters are mainly used as the second step of sewage treatment after septic tanks or after Imhoff tanks, as well as the third step after biological treatment processes when the high quality and stable outflow is required. Sand filters are useful for treatment sewage from single households and from the group of houses, but they also can be used in bigger sewage treatment plants for the public utility objects. The article ends with the summary and conclusions where it is ascertained that the vertical flow sand filters are very good solution regarding household sewage treatment plants, in the areas where the combined sewerage system cannot be applied. Moreover the efficiency of sewage treatment in these objects is high.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2009, 06
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena niezawodności działania oczyszczalni ścieków dla gminy Tuchów
Evaluation of the reliability of the sewage treatment plant for the commune of Tuchow
Autorzy:
Chmielowski, K.
Satora, S.
Walega, A.
Powiązania:
https://bibliotekanauki.pl/articles/61814.pdf
Data publikacji:
2009
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
oczyszczalnie sciekow
oczyszczalnie zbiorcze
niezawodnosc
skutecznosc oczyszczania
scieki
wskazniki zanieczyszczen
Biochemiczne Zapotrzebowanie Tlenu
Chemiczne Zapotrzebowanie Tlenu
zawiesina ogolna
Oczyszczalnia Sciekow Tuchow
Opis:
W artykule określono niezawodność działania oczyszczalni ścieków dla gminy Tuchów. Badania przeprowadzono w okresie od stycznia 2005 do grudnia 2006 roku. Analizie fizyko- chemicznej poddano następujące wskaźniki zanieczyszczenia ścieków: BZT5, ChZTCr, zawiesinę ogólną. W celu określenia poprawnej pracy oczyszczalni obliczono współczynnik niezawodności działania oczyszczalni WN dla każdego z badanych wskaźników. Przedstawiono niezawodność empiryczną. Określono liczbę wystąpień przekroczeń dopuszczalnych wartości wskaźników w stosunku do wartości dopuszczalnej przedstawionej w pozwoleniu wodno-prawnym. Określono również skuteczność zmniejszenia wskaźników w badanym okresie. Przeprowadzone badania wykazały wysoką skuteczność zmniejszenia zanieczyszczeń: BZT5 – 90,7%, ChZTCr – 86,6%, zawiesina ogólna – 90,5%. Obliczone współczynniki niezawodności (WN) badanych wskaźników wyniosły odpowiednio: dla BZT5 – 0,52, dla ChZTCr – 0,31 a dla zawiesiny ogólnej 0,62.
The paper presents the reliability of the sewage treatment plant operation for Tuchów commune. The research was carried out from January 2005 to December 2006. The following sewage pollution ratios were physico-chemically analyzed: BOD5, CODCr, total suspended solids. In order to define the proper treatment plant’s operation, the reliability coefficient was calculated (RC) for each of the tested indexes. The empiric reliability was presented. The amount of transgresions of the admissible index values presented in the water-law permission was described. Moreover, the efficiency of the ratios’ decrease in the tested period was defined. The carried out research showed the high efficiency of the pollutants’ amount decrease: BOD5 – 90,7%, CODCr – 86,6%, total suspended solids – 90,5%. The calculated Reliability Coefficients RC of the analyzed indexes amounted respectively: for BOD5 – 0,52, for CODCr – 0,31 and for total suspended solids 0,62.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2009, 09
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Skuteczność oczyszczania ścieków na przykładzie oczyszczalni dla miasta Krynica-Zdrój
The efficiency of the sewage treatment based on the example of the sewage treatment plant for the city of Krynica-Zdroj
Autorzy:
Chmielowski, K.
Satora, S.
Walega, A.
Powiązania:
https://bibliotekanauki.pl/articles/60239.pdf
Data publikacji:
2009
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
oczyszczalnie sciekow
skutecznosc oczyszczania
scieki
wskazniki zanieczyszczen
Biochemiczne Zapotrzebowanie Tlenu
Chemiczne Zapotrzebowanie Tlenu
zawiesina ogolna
azot ogolny
fosfor ogolny
Oczyszczalnia Sciekow Krynica-Zdroj
Opis:
W artykule przedstawiono skuteczność oczyszczania ścieków na przykładzie oczyszczalni dla miasta Krynica-Zdrój. Badania przeprowadzono w okresie od stycznia 2006 do grudnia 2007 roku. Analizie fizykochemicznej poddano następujące wskaźniki zanieczyszczenia ścieków: BZT5, ChZTCr, zawiesinę ogólną, azot ogólny oraz fosfor ogólny. Obliczono współczynnik niezawodności działania oczyszczalni WN dla każdego z badanych wskaźników. Określono liczbę wystąpień przekroczeń dopuszczalnych wartości wskaźników w stosunku do wartości dopuszczalnej przedstawionej w pozwoleniu wodno-prawnym. Zbadano ponadto skuteczność zmniejszenia wskaźników w badanym okresie. Dodatkowo przedstawiono ilość ścieków dopływająca do oczyszczalni w poszczególnych miesiącach badanego okresu. Przeprowadzone badania wykazały znaczną efektywność usuwania zanieczyszczeń. Średnia redukcja opisywanych wskaźników kształtowała się na poziomie: BZT5 – 95,03%, ChZTCr – 90,98%, zawiesina ogólna – 94,76%, azot ogólny – 79,79%, fosfor ogólny – 63,5%.
The paper presents the efficiency of the sewage treatment based on the example of the sewage treatment plant for Krynica-Zdrój. The research was carried out from January 2006 to December 2007. The following sewage pollution indexes were physico-chemically tested: BOD5, CODCr, total suspended solids, general nitrogen and general phosphorus. The reliability coefficient (RC) was calculated for each of the analyzed indexes. The amount of the transgressions of the admissible index values in relation to the water law permission was defined. Moreover, the effectiveness of the indexes’ decrease in the tested period was analyzed. Additionally the amount of sewage flowing into the treatment plant in each months of the tested period was presented. The carried out research showed the high efficiency of the pollutants’ removal. The average reduction of the tested indexes balanced on the level of: BOD5 – 95,03%, CODCr – 90,98%, total suspended solids – 94,76%, general nitrogen - 79,79%, general phosphorus – 63,5%.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2009, 09
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ temperatury powietrza na temperaturę ścieków w przydomowych oczyszczalniach z filtrem piaskowym o przepływie pionowym
Influence of air temperature on the sewage temperature in the household sewage treatment plants with vertical flow sand filters
Autorzy:
Chmielowski, K.
Walega, A.
Miernik, W.
Powiązania:
https://bibliotekanauki.pl/articles/59917.pdf
Data publikacji:
2009
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
oczyszczalnie sciekow
oczyszczalnie przydomowe
temperatura powietrza
filtry piaskowe
scieki bytowe
scieki surowe
scieki wstepnie oczyszczone
scieki oczyszczone
temperatura sciekow
Opis:
W artykule przedstawiono wyniki badań dotyczących wpływu temperatury otoczenia na temperaturę ścieków w przydomowej oczyszczalni ścieków. Przedmiotowe oczyszczalnie (4 szt.) składały się z osadnika gnilnego i filtra piaskowego o przepływie pionowym każda. Badania przeprowadzono od marca 2003 roku do maja 2006 roku. Pomierzono temperaturę powietrza, ścieków surowych (dopływających do osadnika gnilnego), ścieków wstępnie oczyszczonych (po osadniku gnilnym) oraz ścieków oczyszczonych (na odpływie z filtra piaskowego). Zbadano statystycznie czy, temperatura otoczenia istotnie wpływa na temperaturę ścieków surowych, wstępnie oczyszczonych i oczyszczonych. Na podstawie przeprowadzonych badań stwierdzono, że temperatura powietrza ma istotny wpływ na temperaturę ścieków surowych wstępnie oczyszczonych i oczyszczonych.
The article presents results of analyses concerning the influence of air temperature on the sewage temperature in the household sewage treatment plant. Each of the objective treatment plants (4 of them) consisted of the septic tank and vertical flow sand filter. The research was carried out from March 2003 to May 2006. Air temperature, raw sewage temperature (flowing into the septic tank), primarily treated sewage (after the septic tank) and treated sewage (on the outflow from the septic tank) temperature was measured. The influence of the surrounding temperature on the raw sewage, primarily treated sewage and treated sewage temperature was statistically analyzed. On the basis of the research it was ascertained, that the temperature of the raw, primarily treated and treated sewage is influenced by the air temperature.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2009, 06
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmienność jednostkowego zużycia wody przez mieszkańców Mszany Dolnej
Variability of the unitary average daily water consumption by Mszanian man
Autorzy:
Chmielowski, K.
Satora, S.
Walega, A.
Powiązania:
https://bibliotekanauki.pl/articles/60025.pdf
Data publikacji:
2009
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
miasta
Mszana Dolna
wodociagi
mieszkancy
zuzycie wody
wodomierze
jednostkowe zuzycie wody
zmiany zuzycia wody
Opis:
Wielkość oraz zmienność zużycia wody przez mieszkańców Mszany Dolnej określono na podstawie analizy odczytów z wodomierzy w 35 budynkach w wieloleciu 2001–2007. Przeprowadzona analiza danych wykazała, że jednostkowe średnie dobowe zużycia wody w Mszanie Dolnej wynoszące 78,79 dm3.d-1·M-1 w budynkach jednorodzinnych oraz 83,80 dm3.d-1..M-1 w budynkach wielorodzinnych były zbliżone do zużyć wody występujących w innych miejscowościach Polski południowej. W badanych obiektach odnotowano ciągły spadek zużycia wody, który w okresie badawczym sięgał 25% w budynkach jednorodzinnych oraz 15,5% w wielorodzinnych. Jednostkowe zużycie wody w budynkach jednorodzinnych maleje również wraz ze wzrostem liczby mieszkańców. Największe jednostkowe średnie dobowe zużycie wody w budynkach jednorodzinnych występowało w miesiącach letnich, natomiast minimalne odnotowano jesienią. Różnice w wielkościach zużycia wody w poszczególnych porach roku w budynkach wielorodzinnych są nieznaczne. Średnie jednostkowe zużycie w gospodarstwach domowych było o 21,2% niższe od zużycia normowego, natomiast w budynkach wielorodzinnych różnica ta wynosiła 47,6%.
The volume and variability of water consumption by inhabitants of town of Mszana Dolna was defined on the basis of readings from meters in 35 buildings in the period 2001–2007. The analysis performed showed that the average daily water consumption in Mszana Dolna totalled 78,79 dm3.d-1.M-1 in single family houses and 83,80 dm3.d-1.M-1 in block of apartments, which is similar to water consumption in other places across southern Poland. In the buildings analyzed, a continuous drop in water consumption was recorded, which in the period analyzed reached 25% in houses and 15,5% in blocks of apartments. The number of units of water consumed in houses also decreased despite the increase in the number of inhabitants. Average daily water consumption in single family houses reached a peak in summer, while lowest water consumption levels were recorded in autumn. Differences in water consumption volumes in particular seasons in blocks of apartments are marginal. Average household consumption was by 21,2% lower than the consumption levels specified in the standard, while the difference in block of apartments amounted to 47,6%.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2009, 05
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowe rozwiązania w konstrukcji gum strzykowych
New solutions concerning the construction of teat gums
Autorzy:
Gedymin, M.
Chmielowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/291155.pdf
Data publikacji:
2008
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
trzon wielokątny
guma strzykowa
masaż strzyków
laboratoryjna ocena jakości
polygonal stem
teat gum
teat massage
laboratory assessment
teat
massage quality
Opis:
Porównano zmiany wymiarów pod wpływem naciągu oraz szczelność (dokładność) zamykania się nowych typów gum strzykowych o kwadratowym i trójkątnym przekroju trzonu a także kołowym z pierścieniami usztywniającymi. Przeanalizowano celowość i spodziewane korzyści z wprowadzonych zmian konstrukcyjnych (także w stosunku do innych typów gum strzykowych opisanych w najnowszej literaturze (Internecie)). Wielokierunkowy sposób zamykania się niektórych nowych gum strzykowych wymaga opracowania nowej metodyki oceny nacisków masujących. Zaproponowano nową formułę do teoretycznego obliczenia tych nacisków jako sumę sił nacisku od zakrzywionej ścianki gumy strzykowej oraz od jej swobodnego odcinka pod strzykiem.
Changes in the dimensions under the influence of tension, as well as leaktightness (closure) of new types of teat gums with a square or triangular stem section, and with a circular stem section with stiffening rings, were compared. The purposefulness and the expected benefits resulting from the introduced constructional changes (also in relation to other types of teat gums described in the latest literature (Internet)) were analyzed. The multidirectional way of closing certain new types of teat gums needs the development of new methodology of massage pressure estimation. A new formula was proposed so as to calculate theoretically these pressures as a sum of pressure forces from the curved wall of the teat gum and from its unbounded section under the teat.
Źródło:
Inżynieria Rolnicza; 2008, R. 12, nr 4(102), 4(102); 289-297
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Freshwater biodiversity crisis: macroinvertebrates’ response along the downstream gradient to receiving effluent from a wastewater treatment plant
Autorzy:
Kędzior, R.
Dacewicz, E.
Ziernicka-Wojtaszek, A.
Chmielowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/53639055.pdf
Data publikacji:
2023
Wydawca:
Uniwersytet Warmińsko-Mazurski w Olsztynie / Polskie Towarzystwo Magnezologiczne im. Prof. Juliana Aleksandrowicza
Opis:
Suburban watercourses receiving sewage effluents often are low-flow and not modified, unlike large rivers to which wastewater is discharged. The impact of chemical pollutants on biodiversity as well as the effectiveness of ecosystem recovery and self-purification are worth careful attention. The aim was to assess the macroinvertebrates’ responses to receiving an input from a wastewater treatment plant (WWTP) along the downstream gradient. We studied the variability and recovery pattern of macroinvertebrates in six sections located along a sewage receiving stream continuum. The comparison of chemical parameters showed significant differences in the pH, BOD5, N-NH4+ and PO43-. At sites 100, 300 and 500 m downstream of the WWTP, the persistently high amount of pathogenic coliform bacteria testified to the high impact of bacteriological pollution of sewage on the receiver. Based on 18013 macroinvertebrates, nonmetric multidimensional scaling showed differences between the assemblages at the sections upstream of the WWTP, and located downstream. Effluent discharge affected the macroinvertebrate, causing a decrease of its quantitative index (abundance) by 7% and qualitative index (EPT) by 26% at the site of the sewage discharge. The recovery pattern was manifested by the gradual increase in macoinvertebrate indices at the sites located downstream from the WWTP, which at distances of 300 m and 500 m from the discharge site attained comparable values to those at the reference sites upstream of the WWTP. The populations of the most sensitive taxa were not fully restored with increasing distance from the WWTP, even at a distance of 500 meters, but instead were replaced by more resistant taxa. More attention should be paid to the impact of wastewater discharge from suburban wastewater treatment plants on receiving watercourse biodiversity and ecological water conditions, especially in the case of small and lowflow sewage receivers, where self-purification processes are difficult.
Źródło:
Journal of Elementology; 2023, 28, 4; 1311-1328
1644-2296
Pojawia się w:
Journal of Elementology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie systemu METRONIX do pomiaru zużycia paliwa oraz detekcji pozaeksploatacyjnych ubytków paliwa w lokomotywach spalinowych
Using the Metronix system for the measurement of the fuel consumption and the detection non-exploitation of losses of fuel in diesel engines
Autorzy:
Kowalik, L.
Chmielowski, W.
Szastok, A.
Powiązania:
https://bibliotekanauki.pl/articles/250136.pdf
Data publikacji:
2008
Wydawca:
Instytut Naukowo-Wydawniczy TTS
Tematy:
lokomotywy spalinowe
METRONIX
transport kolejowy
zużycie paliwa
diesel engine
fuel consumption
railway transport
Opis:
Osiąganie przez cenę ropy kolejnych rekordów na świato.wych giełdach paliwowych powoduje, że koszt paliwa staje się w jeszcze większym stopniu kluczowym składnikiem kosztowym eksploatacji lokomotyw spalinowych. Tendencje te wymuszają na przewoźnikach kolejowych prowadzenie świadomej i efektywnej gospodarki paliwowej, mającej na celu zmniejszenie kosztów utrzymania lokomotyw. Wiąże się to z koniecznością pomiaru zużycia paliwa przez lokomotywę, pomiaru ilości tankowanego paliwa oraz detekcji pozaeksploatacyjnych ubytków paliwa, w tym i wykrywanie nadużyć. Jest to szczególnie ważne w lokomotywach eksploatowanych od wielu lat, które doposażane są w układy pomiaru zużycia paliwa, podczas ich modernizacji czy remontów. Nowe typy loko.motyw z reguły wyposażone są w nowoczesne układy pomiarowe, umożliwiające dokładny pomiar zużycia paliwa na cele trakcyjne, z reguły bazujące na pomiarze ilości paliwa podawanego na wtryski silnika.
Źródło:
TTS Technika Transportu Szynowego; 2008, 9; 43-47
1232-3829
2543-5728
Pojawia się w:
TTS Technika Transportu Szynowego
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies