Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "water treatment sludge" wg kryterium: Wszystkie pola


Tytuł:
Recovery of Alum from Surabaya Water Treatment Sludge using Electrolysis with Carbon-Silver Electrodes
Autorzy:
Barakwan, Rizkiy Amaliyah
Hardina, Tyta Try
Trihadiningrum, Yulinah
Bagastyo, Arseto Yekti
Powiązania:
https://bibliotekanauki.pl/articles/123042.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
alum
drinking water
electrolysis
recovery
sludge
Opis:
Untreated alum sludge from Surabaya water treatment plant (WTP), which contained high concentration of alum was directly discharged into Surabaya River. It might cause problems because of the accumulation of aluminum in the lower part of the river. Alum could be recovered from the drinking water sludge using the electrolysis method. Aims of this study were to determine the optimum pH and electrical current for electrolysis using carbon-silver electrodes to recover aluminum coagulant from the sludge, and to determine the amount of the recovered alum. The sludge was acidified prior to electrolysis. Acidification was done by adding sulfuric acid at pH 3 and 4. Polarization test was conducted at 100, 200, and 300 mA, in order to determine the optimum electrical current. The electrolysis was performed in one compartment batch recirculation reactor, using silver as cathode and carbon as anode for 10 hours. Values of pH were measured every hour. The precipitated matter in the cathode was weighed, and analysed by means of Inductively Coupled Plasma. The optimum conditions of the electrolysis were achieved at initial pH 3 and electrical current 300 mA. The electrolysis resulted in the highest precipitate of 2.6112 g in the cathode.
Źródło:
Journal of Ecological Engineering; 2019, 20, 7; 126-133
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Use of nanofiltration membranes to concentrate and recover leached aluminum from acidified water treatment sludge
Autorzy:
Cheng, W. P.
Chen, P. H.
Tian, D. R.
Yu, R. F.
Fu, C. H.
Powiązania:
https://bibliotekanauki.pl/articles/208030.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
water purification
nanofiltration
acidic solutions
leaching
roztwory kwaśne
oczyszczanie wody
nanofiltracja
ługowanie
glin
Opis:
The recovery of aluminum from water purification sludge is usually performed by making the solution acidic or basic. However, for economic reasons and reasons of safety, excessive doses of acid or base should not be utilized. Accordingly, the aluminum concentration in the leached solution is typically limited, thus the recovered aluminum cannot be directly reused as a coagulant. A nanofiltration (NF) membrane can be used in the acidic solution to concentrate high-valence metal ions. There-fore, in this work, H2SO4 was utilized to leach Al3+ ions from water purification sludge. Then, the Al3+ ion solution was concentrated using a low-price NF membrane. The effect of natural organic matter on the Al3+ ion concentrating efficiency in the filtration process has been elucidated. Experimental results reveal that Al3+ ions were effectively prevented from passing through the NF membrane, enabling a highly concentrated aluminum solution to be obtained. However, the presence of organic compounds may reduce the efficiency of the concentration of Al3+ ions in the solution.
Źródło:
Environment Protection Engineering; 2016, 42, 3; 19-32
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Próba oceny możliwości wykorzystania osadów z procesów klarowania wody do strącania związków fosforu w oczyszczalniach ścieków komunalnych
An attempt at assessment of possibilities for utilization of sludge produced during water clarification for phosphorus precipitation in municipal wastewater treatment plants
Autorzy:
Balcerzak, W.
Łuszczek, B.
Powiązania:
https://bibliotekanauki.pl/articles/236614.pdf
Data publikacji:
2015
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
osady z oczyszczania wody
koagulanty
oczyszczanie ścieków
usuwanie fosforu
water treatment sludge
coagulants
wastewater treatment
phosphorus removal
Opis:
Przedstawiono wyniki badań laboratoryjnych mających na celu ocenę możliwości zagospodarowania osadów powstających w zakładach wodociągowych w oczyszczalniach ścieków komunalnych. W tym celu wykonano analizę składu osadów pochodzących z układów oczyszczania wód powierzchniowych w Krakowie, z uwzględnieniem specyfiki osadów pokoagulacyjnych i osadów z wód popłucznych. Próbki tych osadów wykorzystano w testach laboratoryjnych do strącania związków fosforu w ściekach komunalnych i przefermentowanych osadach ściekowych pochodzących z krakowskich oczyszczalni. Wyznaczone dawki badanych osadów wskazują na znacznie większe możliwości praktycznego wykorzystania osadów pokoagulacyjnych niż osadów z wód popłucznych. Uzyskane w tym zakresie rezultaty były korzystne zwłaszcza w przypadku ścieków komunalnych i wskazują na możliwość ograniczenia zużycia klasycznych koagulantów stosowanych do strącania związków fosforu. W badaniach stwierdzono także usuwanie siarczków ze ścieków. Uzyskane wyniki wskazują na celowość rozważenia możliwości wykorzystania osadów z klarowania wody zarówno w samych oczyszczalniach ścieków, jak i przez ich wprowadzenie bezpośrednio do strumienia ścieków w sieci kanalizacyjnej. Dalsze prace w tym zakresie, oprócz pogłębienia wiedzy o mechanizmach badanego procesu, powinny koncentrować się na ocenie ewentualnych negatywnych skutków związanych na przykład ze zwiększeniem masy osadów kierowanych do dalszej przeróbki, a także na ocenie aspektów ekonomicznych i eksploatacyjnych tego procesu.
The results of laboratory studies aimed at an assessment of possibilities for utilization of water treatment sludge produced in municipal plants were presented. For this purpose, content analysis was performed for the sludge coming from surface water treatment systems of Krakow, taking account of post-coagulation sludge and filter backwash sludge specifics. The sludge samples were used in the laboratory tests for phosphorus precipitation in municipal sewage and digested sewage sludge from Krakow treatment plants. The amounts of sludge tested indicated much wider possibilities for management of the post-coagulation compared to the backwash sludge. The results were clearly beneficial especially in case of the municipal sludge and pointed to a possible reduction in the amount of commercial coagulants applied to phosphorus precipitation. Additionally, sulfide removal from the sludge was noted. The study results indicate that it is purposeful to consider the possibility of utilization of sludge from water clarification, both in treatment plants alone and by introducing it directly into the sludge stream in a sewer system. Further studies should, beside extending the knowledge on the mechanisms of studied processes, focus on the evaluation of potential adverse effects related to e.g. increase in the amount of sludge directed for further processing as well as on the assessment of economic and operating aspects of the process.
Źródło:
Ochrona Środowiska; 2015, 37, 3; 57-60
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza możliwości poprawy parametrów transportu hydraulicznego osadów z oczyszczania wody
Analyzing the possibility of improving the parameters of hydraulic transport for sludge generated during water treatment
Autorzy:
Janik, M.
Kuś, K.
Powiązania:
https://bibliotekanauki.pl/articles/237385.pdf
Data publikacji:
2011
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
osady z oczyszczania wody
właściwości reologiczne
dezintegracja mechaniczna
mieszanie osadów
water treatment sludge
rheological properties
mechanical disintegration
sludge mixing
Opis:
W zakładach oczyszczania wody powstają znaczne ilości osadów, które wymagają zagęszczenia przed końcową utylizacją. Proces mieszania nadaje się do wykorzystania w ciągu przeróbki osadów, pozwalając na rozdrobnienie cząstek zagęszczonych mechanicznie osadów i zmieniając istotnie ich właściwości reologiczne. W badaniach określono właściwości reologiczne osadu pokoagulacyjnego mechanicznie zagęszczonego (sucha masa 3,5÷4,5%) oraz poddanego dodatkowo procesowi dezintegracji mechanicznej. Parametry reologiczne wyznaczono w badaniach wiskozymetrycznych wykorzystując dopasowany model potęgowy Ostwalda-de Waele'a. Pomiary wykonano w reometrze rotacyjnym stosując metodykę dopasowaną do osadów kłaczkowatych o właściwościach tiksotropowych. Wykazano, że na kształt krzywej płynięcia osadu znaczący wpływ miała zawartość suchej masy oraz warunki mieszania. Dezintegracja osadu istotnie ograniczyła straty podczas przepływu w rurociągach. Ze względu na zmienność właściwości oraz warunków mieszania osadów, wskazuje się na konieczność indywidualnego podejścia do procesu dezintegracji osadów z oczyszczania wody oraz obliczeń przepływu zagęszczonych osadów w rurociągach.
Water treatment plants produce large volumes of sludge that requires thickening prior to utilization. The use of mixing is recommendable during sludge processing, since this causes the particles of the mechanically thickened sludge to disintegrate, and consequently changes favorably its rheological properties. Within the scope of the study reported on in this paper determined were the rheological properties of coagulation sludge, which was mechanically thickened (3.5-4.5% of dry solids content) and additionally subjected to mechanical disintegration. Rheological parameters were determined by viscosimetry, using the Ostwald-de Waele model. Measurements were performed in a rotational rheometer, using methods adapted to flocculated sludge with thixotropic properties. It has been demonstrated that the flow curve of the sludge was strongly influenced by the dry solids content and mixing conditions. The disintegration of the sludge significantly reduced friction losses during flow in the pipeline. The variable properties of the sludge, as well as the equally variable mixing conditions, substantiate the necessity of an individual approach to the disintegration process and to the computation of thickened sludge flow in the pipeline.
Źródło:
Ochrona Środowiska; 2011, 33, 3; 53-57
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Organic Compounds of Natural Origin in Sludge from Waste-Water Treatment Plant
Związki organiczne pochodzenia naturalnego w osadach z oczyszczalni ścieków
Autorzy:
Kucharova, J.
Raclavska, H.
Raclavsky, K.
Powiązania:
https://bibliotekanauki.pl/articles/319169.pdf
Data publikacji:
2014
Wydawca:
Polskie Towarzystwo Przeróbki Kopalin
Tematy:
waste–water treatment sludge
organic compounds
humification
mineralization
Py-GC/MS
przeróbka ścieków i osadów
związki organiczne
humifikacja
mineralizacja
Opis:
Organic compounds of natural origin were analyzed in three types of sludge produced by waste water treatment plant – limed sludge with 12 % of CaO, limed sludge with 6% of CaO and sludge without processing. Analysis was performed by pyrolytic gas chromatography with mass spectrometry detection (Py-GC/MS). The main component pf natural origin in waste-water treatment sludge were determined. They comprise compounds form the following groups: fatty acids and their methylesters, steroids, substances derived from polysaccharides, substances derived from lignin, compounds with nitrogen (both heterocyclic and aliphatic), substances with so called non-specific origin (toluene, styrene, acetic acid, methylphenols and phenols). Interpretation was attempted for identification of organic compounds sources as well as determination of humification and mineralization degree. The ratio benzene/toluene was used as the criterion for humification in waste-water treatment sludge. Benzene is derived from degradation of condensed aromatic structure, toluene is derived from both condensed aromatic structures and pseudostable organic matter. The ratio furfural/pyrolle was used of expression of mineralization degree of organic matter. Furfural is a product of labile organic matter (saccharides) while pyrolle originates from stable organic matter (humified components containing nitrogen). Compared with non-limed sludges, limed sludges have higher rate of decomposition of organic matter as well as subsequent mineralization. Limed sludges accumulate more compounds derived from lignine which is caused by more intensive decomposition of polysaccharides. From the point of view of utilization in agriculture, limed sludge is the most suitable sludge produced by waste-water treatment.
Przeanalizowano związki organiczne pochodzenia naturalnego w trzech typach osadów wytwarzanych przez oczyszczalnie ścieków - szlam wapnowany zawierający 12% CaO, szlam wapnowany z 6% CaO i osady nieprzetworzone. Analizę przeprowadzono za pomocą pirolitycznej chromatografii gazowej ze spektrometrią masową (Py-GC / MS). Określono główne składniki pochodzenia naturalnego w osadach z oczyszczalni ścieków. Stanowią one związki z następujących grup: kwasy tłuszczowe oraz ich estry metylowe, steroidy, substancje pochodzących z polisacharydów, substancje pochodzące z ligniny, związki z azotem (zarówno heterocyklicze i alifatyczne), substancje o tzw. niespecyficznym pochodzeniu (toluen, styren, kwas octowy, metylofenole i fenole). Przedstawiono próbę identyfikacji źródeł związków organicznych, a także określenia stopnia humifikacji i mineralizacji. Stosunek benzenu do toluenu stosuje się w osadach z oczyszczalni ścieków jako kryterium humifikacji. Benzen jest pochodną z degradacji skondensowanej struktury aromatycznej, toluen pochodzi zarówno ze skondensowanych struktur aromatycznych jak i z pseudostabilnej materii organicznej. Stosunek furfural/pyrol użyto w celu ekspresji stopnia mineralizacji materii organicznej. Furfural jest produktem nietrwałej substancji organicznej (sacharydy), a pyrol pochodzi ze stabilnej materii organicznej (nawilżonych składników zawierających azot). W porównaniu z niewapnowanymi osadami, osady wapnowane mają wyższy wskaźnik rozkładu materii organicznej, jak i późniejszej mineralizacji. Wapnowane osady gromadzą więcej związków pochodzących z ligniny co jest spowodowane bardziej intensywnym rozkładem polisacharydów. Z punktu widzenia wykorzystania w rolnictwie, szlam wapnowany jest najbardziej odpowiednim osadem wytwarzanym przez oczyszczalnie ścieków.
Źródło:
Inżynieria Mineralna; 2014, R. 15, nr 2, 2; 61-66
1640-4920
Pojawia się w:
Inżynieria Mineralna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Water and sewage sludge co-digestion : characteristic of the process and its possible applications
Współfermentacja osadów ściekowych i z uzdatniania wody : charakterystyka procesu i możliwości zastosowania
Autorzy:
Górka, Justyna Łucja
Cimochowicz-Rybicka, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/204961.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
water treatment sludge
sewage sludge
co-fermentation
biogas
disintegration
dewatering
uzdatnianie wody
osad ściekowy
ko-fermentacja
biogaz
rozpad
odwadnianie
Opis:
The article describes problems related to intensification of energy production at a sewage treatment plant. The authors analyze anaerobic co-digestion of sludge from a water treatment plant and sewage treatment plant. The authors proposed a methodology of the research and analyzed the preliminary results, which showed that co-digestion of sewage and water sludge enhanced biogas production. The authors hope that the results of the study will provide a basis for development of methodology for sludge control and disposal.
Badania zaprezentowane w niniejszej publikacji, prowadziły do określenia możliwości wykorzystania osadów z uzdatniania wody jako substrat w procesie fermentacji metanowej osadów ściekowych. Autorzy zaproponowali metodologię badań i przeanalizowali wstępne wyniki, które wykazały, że dodanie osadów z uzdatniania wody do osadów ściekowych spowodowało zwiększoną produkcję biogazu. Zaproponowana technologia stanowi zintegrowany system gospodarki komunalnej, oparty na współpracy dwóch przedsiębiorstw: oczyszczalni ścieków i stacji uzdatniania, działających w systemie gospodarki cyrkulacyjnej. Rezultatem takiego rozwiązania są korzyści w zakresie odzysku biogazu, możliwego do wykorzystania w procesie kogeneracji.
Źródło:
Archives of Environmental Protection; 2019, 45, 1; 84-91
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary study of hot mix asphalt containing water treatment and sewage sludge
Autorzy:
Bastidas-Martínez, J. G.
Camapum de Carvalho, J.
Lucena, L. C.
Farias, M. M.
Rondón-Quintana, H. A.
Powiązania:
https://bibliotekanauki.pl/articles/230585.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
osad
uzdatnianie wody
osad ściekowy
wypełniacz mineralny
mieszanka asfaltowa gorąca
water treatment
sludge
sewage sludge
mineral filler
hot mix asphalt
Opis:
Throughout the world, considerable quantities of water treatment sludge (WTS) and sewage sludge (SS) are produced as waste. This study assessed in the laboratory, the possibility to use both waste products when they are incorporated as filler at 1% with relation to the total mass of a hot mix asphalt - HMA. To this end, both waste products were initially reduced to ash through a calcination process. Resistance tests under monotonic load (Marshall and indirect tension tests), and cyclic load (resilient modulus test) were applied on mixes that contained WTS and SS. Besides, moisture damage (modified Lotmman test), and abrasion (Cantabro) resistance were assessed. An analysis of variance (ANOVA) test was performed in order to verify if the results are statically equal or not to those of the control HMA. As a general conclusion, it is reported that both materials show a resistance increase under monotonic load and higher stiffness under cyclic load (cohesion) when they are incorporated into the mix as filler despite the fact that the asphalt content used was less than the control mix. However, some problems are observed associated with moisture damage resistance, and friction wear (adherence).
Źródło:
Archives of Civil Engineering; 2020, 66, 1; 225-240
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metale ciężkie w osadach powstających przy uzdatnianiu wody
Heavy metals in post-coagulation sludge from water treatment
Autorzy:
Płonka, I.
Pieczykolan, B.
Amalio-Kosel, M.
Loska, K.
Powiązania:
https://bibliotekanauki.pl/articles/126867.pdf
Data publikacji:
2012
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
metale ciężkie
osady pokoagulacyjne
oczyszczanie wody
heavy metals
post-coagulation sludge
water treatment
Opis:
Głównym źródłem zaopatrywania w wodę przeznaczoną do spożycia są wody powierzchniowe. Szacuje się, że w Polsce ok. 50% wody jest pobierane z ujęć powierzchniowych, tj. rzek, jezior i zbiorników zaporowych, z czego ok. 15% stanowią wody infiltracyjne. Aby woda mogła trafić do odbiorców, musi zostać poddana odpowiednim procesom oczyszczania. Do najczęściej stosowanych jednostkowych procesów oczyszczania wody powierzchniowej należą koagulacja i filtracja. Z tego względu w zakładach uzdatniania wody powstają głównie osady pokoagulacyjne. Osady te zawierają wszystkie zanieczyszczenia usuwane z wody surowej pobieranej do oczyszczania, w tym również metale ciężkie. W pracy przedstawiono wyniki badań zawartości metali ciężkich w osadach pokoagulacyjnych powstających w dwóch zakładach uzdatniania wody: Zakładzie Produkcji Wody I (ZPW I) i Zakładzie Produkcji Wody II (ZPW II). Zakłady te różnią się stosowaną technologią oczyszczania wody oraz charakterem zbiorników wody powierzchniowej. Osady do badań pobierano w ciągu całego roku w celu określenia wpływu zmian jakości wody surowej na zawartość metali ciężkich w osadach. Oznaczenie zawartości metali ciężkich: niklu, miedzi, chromu, cynku, kadmu, ołowiu i rtęci wykonano dla zmineralizowanych próbek metodą AAS.
The main sources of water supply for human consumption are the surface water. It is estimated that in Poland about 50% of water is collected from surface water intakes, rivers, lakes and reservoirs, of which about 15% are water infiltration. Raw water must be subjected to appropriate treatment processes before it is directed to human consumption. The most commonly treatment processes used of surface water are coagulation and filtration. Therefore, water treatment plants are precipitated post-coagulation sludge. This post-coagulation sludge contains all the pollution which is removed from treated raw water, including heavy metals. The paper presents the results of researches of contents heavy metals in post-coagulation sludge collected from two water treatment plants: Water Treatment Plant I (WTP I) and Water Treatment Plant II (WTP II). These plants differ in used water treatment technology and the nature of surface water reservoirs. Post-coagulation sludge were taken throughout the year to determine the impact of raw water quality changes on the content of heavy metals in the sludge. Determination of heavy metals: nickel, copper, chromium, zinc, cadmium, lead, mercury was made for the mineralized samples by AAS method.
Źródło:
Proceedings of ECOpole; 2012, 6, 1; 337-342
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Current stage of knowledge relating to the use ferruginous sludge from water treatment plants – a preliminary review of the literature
Autorzy:
Wołowiec, Magdalena
Bajda, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/127615.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Mineralogiczne
Tematy:
water treatment residuals
reuse
water treatment
plant sludge management
Opis:
In water treatment plants, a large amount of wastewater and sludge is generated during the processing of drinking water. The composition of the sludge is determined by the type and raw water chemistry, as well as the methods and materials used for purification. The major components of the sludge are iron and manganese oxyhydroxides. In the past, the sludge was landfilled, but for environmental reasons it became necessary to find uses for the sludge. The aim of this study was to identify examples of using this sludge. Nowadays, the sludge is applied in the treatment of municipal wastewater, agriculture, and the production of cement and bricks, among others. Attention was also paid to the possibility of using the water processing sludge in different sorption applications.
Źródło:
Mineralogia; 2017, 48, 1/4; 39-45
1899-8291
1899-8526
Pojawia się w:
Mineralogia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Post-coagulation sludge management for water and wastewater treatment with focus on limiting its impact on the environment
Zagospodarowanie osadów po procesie koagulacji wody, celem ograniczenia ich wpływu na środowisko
Autorzy:
Łukasiewicz, Ewelina
Powiązania:
https://bibliotekanauki.pl/articles/434998.pdf
Data publikacji:
2016-12-15
Wydawca:
Uniwersytet Opolski
Tematy:
post-coagulation sludge
sludge management
water treatment
osad pokoagulacyjny
gospodarka osadowa
oczyszczanie wody
Opis:
Water treatment process produces great amount of sludge. According to growing interest in sustainable development and environment protection, sludge management problem should be taken into consideration. Accordingly, its recovery, recycling and reuse are optimal solutions for Water Treatment Sludge(WTS) management. The conventional Water Treatment Plants (WTP) produce even up to 100 000 ton/year of sludge. The coagulation process produces a huge amount of sludge. This contamination may be recovered and reused. Some amount of coagulants may be recovered and reused during the wastewater treatment process. The Water Treatment Sludge with e.g. iron or alum content, may be also used as a coagulant at a wastewater treatment plant. In the course of this paper, few methods for post-coagulation sludge management are presented.
Proces oczyszczania wody skutkuje powstaniem dużej ilości osadów. Polityka zrównoważonego rozwoju, wymaga bezpiecznych dla środowiska działań proekologicznych, związanych z gospodarką wodno-ściekową. Zgodnie z tym stosuje się metody odzysku, recyklingu oraz ponownego użycia w stosunku do osadów powstających podczas uzdatniania wody.Proces koagulacji wód powierzchniowych i podziemnych powoduje powstanie dużej ilości osadów. Konwencjonalna stacja uzdatniania wody może produkować nawet do 100000 ton osadu rocznie. W niniejszej pracy przedstawiono metody stosowane w gospodarce osadowej, takie jak między innymi odzysk koagulantów z osadów, użycie osadu jako koagulantu na stacjach uzdatniania oraz oczyszczalniach ścieków, zastosowanie osadów jako kompozytu w budownictwie, stabilizację tlenową osadu celem zmniejszenia jego ilości, poprzez redukcję materiału organicznego.
Źródło:
Economic and Environmental Studies; 2016, 16, 4(40); 831-841
1642-2597
2081-8319
Pojawia się w:
Economic and Environmental Studies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Usuwanie fosforanów z wykorzystaniem osadów potechnologicznych pochodzących ze stacji uzdatniania wody
Removal of Phosphates with Post-technological Sludge from Water Treatment Plant
Autorzy:
Totczyk, G.
Klugiewicz, I.
Pasela, R.
Górski, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/1818613.pdf
Data publikacji:
2015
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
osady z uzdatniania wody
osady pokoagulacyjne zawierające glin
defosfatacja
TZB
oczyszczalnia ścieków
water processing sludge
alumina water processing sludge
dephosphatation
RBC
sewage treatment plant
Opis:
With the treatment of water, especially surface waters, there is produced a high amount of sewage and sludge. They make up a serious ecology problem that due to a high volume and the content of sludge of iron or aluminium oxide-hydroxide or, pollution which occur in the intaken water (mineral and organic substances, algae, protozoa and bacteria) as well as the chemicals added. The environmental protection requires limiting materials as well as it makes you search for effective waste management problem-solving methods. The waste generated at present during water treatment most often undergo dehydration and drying and then they are deposited at the landfill site. The currently binding environmental protection law makes you look for the possibilities of the use of sludge as recycled materials, e.g. in brick factories, cement factories or with sewage treatment. Sludge containing aluminium or iron can be used e.g. in the process of municipal sewage treatment. The application of sludge containing aluminium for dephosphatation has the advantage of protecting the system from secondary release of precipitated phosphates in the environment deprived of dissolved oxygen. The possibilities of sludge application to remove phosphates differ, depend not only on the sludge characteristics but also on the sewage treatment process. The article demonstrates the results of research into using sludge derived from water treatment station in Lubicz to remove phosphates from sewage. At present the sludge after sedimentation and mechanical dehydration with the filtration press finally reaches the municipal landfill site. The sludge, applied for research, concentrated in settling vessels, is a mixture of post-coagulation sludge and washings from anthracite-sand and carbon filters. Its hydration accounting for 98,7% shows a high colour, above 80 mg Pt/dm3, it contains about 2,6 g/dm3 of aluminium as well as organic compounds expressed with BOD5 value equal 170 mg O2/dm3. The sludge shows a high COD of 3990 mg O2/dm3, and organic substance – for 31,6% of dry weight. The study of effectiveness of the removal of phosphates was made with the vessel test method. The sludge was dispensed at a changing volume from 0,5 to 100 cm3 per 1 dm3 of prepared water and then sewage. Both in water and in sewage there was recorded a 90% removal of phosphates by applying 80 cm3 of sludge per 1 dm3 of the sample. Additionally there was investigated the effect of dispensed sludge on the effectiveness of sewage treatment with the model of the treatment plant with rotating biological contactors. Applying the rate of 40 cm3 of sludge per 1 dm3 produced 96,0% elimination of COD, 97,7% removal of organic compounds characterised with the values of COD and BOD5 as well as 100% removal of phosphates. Finally it was found that it is possible to use the sludge to remove phosphates from sludge. During dephosphatation there was reported no use-up of the natural alkalinity of sewage. Sludge dispensing did not result in a decrease in the effectiveness of sewage treatment with the method of rotating biological contactors. The research is preliminary in nature and it needs to be continued.
Źródło:
Rocznik Ochrona Środowiska; 2015, Tom 17, cz. 2; 1660-1673
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie osadów potechnologicznych z uzdatniania wody do poprawy właściwości sedymentacyjnych osadu czynnego
Use of Post-technological Sludge from Water Treatment to Improve Sedimentation Properties of Activated Sludge
Autorzy:
Masłoń, A.
Opaliński, I.
Powiązania:
https://bibliotekanauki.pl/articles/1813892.pdf
Data publikacji:
2017
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
osad pokoagulacyjny
popłuczyny
osad czynny
osad spęczniały
post-coagulation sludge
backwash water
activated sludge
sludge bulking
Opis:
Przedmiotem opracowania jest określenie wpływu osadów potechnologicznych z uzdatniania wody na właściwości sedymentacyjne osadu czynnego. Przetestowane zostały popłuczyny z uzdatniania wód podziemnych oraz osad pokoagulacyjny z uzdatniania wód powierzchniowych. Badania przeprowadzono w warunkach laboratoryjnych na podstawie obserwacji opadalności osadu czynnego z dodatkiem zróżnicowanych objętości materiałów. Do oceny efektywności zastosowanych osadów potechnologicznych określono opadalność V30 i V60 (objętość osadu odpowiednio po 30 i 60 min. sedymentacji), indeks osadu czynnego, indeksu Donaldsona (indeksu gęstości osadu) oraz prędkość sedymentacji vs. Dodatkowo w celu weryfikacji poprawy opadalności z dodatkiem reagentów wprowadzono wskaźnik opadalności Wo będący ilorazem V30/V60. Badania wykazały przydatność zastosowania osadów potechnologicznych z uzdatniania wody do poprawy właściwości sedymentacyjnych osadu czynnego. Popłuczyny z uzdatniania wód podziemnych osiągnęły najwyższe efekty wspomagania osadu czynnego. Odnotowano maksymalnie 21,6% oraz 26,4% zmniejszenie indeksu osadu czynnego odpowiednio przy dawkowaniu osadu pokoagulacyjnego i popłuczyn. Maksymalny stopień poprawy prędkości sedymentacji osiągnięto przy najwyższych dawkach osadów technologicznych, odpowiednio 58,1% (OP) oraz 75,3% (PP). Mechanizm poprawy sedymentacji osadu czynnego z dodatkiem osadów potechnologicznych jest trudny do określenia, bowiem z jednej strony osad pokoagulacyjny i popłuczyny stanowią zawiesinę, w której obecne są cząstki mineralne o wielkości poniżej 200 µm będące obciążnikiem kłaczków osadu czynnego. Z drugiej jednak strony obecność żelaza w popłuczynach i glinu w osadach pokoagulacyjnych może wpływać na proces opadalności w analogiczny sposób jak koagulanty chemiczne PIX i PAX.
The aim of the paper is the evaluation of post-technological sludge from Water Treatment Plant on improvement of sedimentation properties of activated sludge. The post-coagulation sludge from surface water treatment (OP) and backwash water from groundwater treatment (PP) were used in this study. The studies were performed in the laboratory scale by observing the settleability of activated sludge with the addition of different volume of post-technological sludge. The activated sludge quality used in this study was characterised by a strong sludge bulking and a wide range of sludge volume index. For the evaluation of the efficiency of tested materials in activated sludge the settleability after 30 V30 and V60 minutes, the sludge volume index SVI, the Donaldson index SDI (Sludge Density Index) and value settling velocity vs were determined. Additionally, in order to verify of activated sludge settleability with the addition of post-technological sludge was appointed a sludge settling ratio (Wo) which is a quotient of V30 and V60. Studies showed the usefulness of the application of post-technological sludge from water treatment to improve of sedimentation properties of the activated sludge. Settling tests showed different efficiencies in the activated sludge settleability, depending on the type and amount of post-technological sludge. At a dosage of post-coagulation sludge and backwash water was observed up to 21.6% and 26.4% reduction of sludge volume index. The maximum level of improvement of settling velocity at the highest doses of post-technological sludge amounted to 58.1% (OP) and 75.3% (PP). Better effects of improvement of activated sludge sedimentation were obtained using backwash water than post-coagulation sludge. The mechanism of improvement of sedimentation properties of the activated sludge containing post-technological sludge is difficult to determine. On the one hand the post-coagulation sludge and backwash water are a suspension, wherein the mineral particles are present, which is a weight of activated sludge flocs. The incorporation of particles into flocs of activated sludge increases its relative density On the other hand, the presence of iron ions in backwash water and aluminum ions in post-coagulation sludge may affect the sedimentation activated sludge in the same manner as the chemical coagulant. The backwash water or post-coagulation sludge may be a new effective reagent in activated sludge technology.
Źródło:
Rocznik Ochrona Środowiska; 2017, Tom 19; 745-759
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Jakość wód osadowych odpływających podczas mechanicznego odwadniania osadów z gospodarstw rybackich
Effectiveness of treatment of the water sludge in the process of conditioning and dewatering of the sludge from a fish farm
Autorzy:
Rynkiewicz, M. R.
Powiązania:
https://bibliotekanauki.pl/articles/125985.pdf
Data publikacji:
2014
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
kondycjonowanie osadów
odwadnianie osadów
wody osadowe
zanieczyszczenia
związki fosforu
ortofosforany
conditioning of sludge
dewatering of sludge
water from sludge
leachate
pollution
phosphorus compounds
orthophosphate
Opis:
Wody osadowe odpływające podczas mechanicznego odwadniania osadów ściekowych charakteryzują się najczęściej wysoką zawartością związków biogennych, dlatego podjęto badania, których celem było określenie jakości wód osadowych uzyskiwanych podczas odwadniania osadów kondycjonowanych siarczanem żelaza(III), siarczanem glinu lub tlenkiem wapnia. Każdy z przebadanych związków miał inny wpływ na jakość odcieków uzależniony głównie od zastosowanej dawki, jak i właściwości osadów. Siarczan żelaza i siarczan glinu zatrzymywał związki fosforu tylko w określonym zakresie pH. Wprowadzenie do osadów siarczanu żelaza w ilości powyżej 15,5% s.m. oraz powyżej 5,0% s.m. w przypadku siarczanu glinu skutkowało znacznym obniżeniem odczynu i wzrostem zawartości ortofosforanów w wodach osadowych. Zastosowany do kondycjonowania osadów tlenek wapnia wykazywał się skutecznością w zatrzymywaniu ortofosforanów w całym przebadanym zakresie dawek. Jednocześnie odcieki odpływające podczas stosowania tego związku charakteryzowały się wzrastającą wartością pH i ChZT.
During mechanical sludge dewatering the filtrate is produced. Filtrate is usually characterized by a high content of nutrients. In order to determine the possibility of simultaneous process of dewatering and retention of phosphorus compounds in the sludge, the studies have been carried out using organic and inorganic coagulant in the process of conditioning. These treatments have an impact both on the efficiency of the dewatering process and the characteristics of water flowing from the sludge. The studies was conducted in the laboratory using the sludge from a fish farm applying an industrial the fattening of the rainbow trout. For the conditioning of the sludge inorganic metal salts were used: iron sulfate, aluminum sulfate and calcium oxide. The sludge used in the studies characterized a high content of phosphorus, which had an impact on the concentration of these components in the water from the sludge. The use of coagulants in the process of conditioning influenced both positively and negatively on the quality of the effluent leachate. It was dependent on the type of conditioning agent, the size of the dose and the sludge characteristics. High doses of ferrous sulfate and aluminum sulfate resulted in a reduction to a value of pH of the sludge at which phosphorus compounds did not precipitated. In these conditions an increase of the contents of these compounds in the sludge water was observed. With the increase of the dose of the calcium oxide used for the conditioning of the sludge the efficiency of the phosphorus compounds removal was increased. This water from the sludge also characterized by a high pH value, which contributed to their hygenization.
Źródło:
Proceedings of ECOpole; 2014, 8, 1; 274-278
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermodynamic Analysis and Mathematic Modeling of Waste Sludge from Drinking Water Treatment Plants
Autorzy:
Azeddine, Fantasse
El Khadir, Lakhal
Ali, Idlimam
Powiązania:
https://bibliotekanauki.pl/articles/2026746.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
drinking water sludge
sludge valorization
wastewater management
thermodynamic analysis
isosteric heat
Opis:
Water treatment annually produces a huge amount of Drinking Water Treatment Sludge (DWTS) wastes. The latter causes environmental problems in Morocco in terms of energy and pollution. Therefore, cost-effective and eco-friendly solutions for managing them should be proposed in order to reduce the frequency of storage along with transportation costs. In this paper, a thermodynamic analysis of DWTS wastes was conducted based on the isosteric heat and compensation theory. Different results concerning the mineralogical identification of sludges were established. Findings revealed that the by-product of water purification was mainly composed of aluminum, silica and iron hydroxides, with pH varying between 6.23 and 6.85. The suspended matter was between 18.3 and 19.6 m/l. The volatile matter of the three sludge samples was between 18 and 21%. The measured dry matter content was between 13.41 and 15.23%. The experimental tests were performed under temperatures from 45 and 60 °C, the experimental data of the sorption curves were fitted by using several models of correlation. Furthermore, the analysis showed that the Peleg’s model perfectly described the isotherm curves in the activities ranging from 0 to 90%. The net isosteric heats of sorption of the three hydroxide sludge from the Moroccan treatment station: $S_k$, $S_m$ and $S_s$, were determined for desorption and adsorption. Moreover, it was revealed that the equilibrium water content rising lead contributed to the reduction of the net isosteric heat and the entropy of sorption. Finally, the enthalpy-entropy compensation showed that the sorption mechanism involved was enthalpy driven.
Źródło:
Journal of Ecological Engineering; 2022, 23, 2; 140-149
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of SS-VF Bed for the Treatment of High Concentrated Reject Water from Autothermal Termophilic Aerobic Sewage Sludge Digestion
Autorzy:
Dąbrowski, W.
Malinowski, P.
Karolinczak, B.
Powiązania:
https://bibliotekanauki.pl/articles/123643.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
autothermal thermophilic aerobic digestion
ATAD
reject water
vertical flow constructed wetland
SS VF
Opis:
The autothermal termophilic aerobic digestion (ATAD) technology is used in the municipal and industrial wastewater treatment plants (WWTPs) with personal equivalent up to 30.000. The process provides a high level of sewage sludge stabilization and its hygienization. The main operation problems are caused by the high concentration of nitrogen and phosphorus in the reject water from sewage sludge treatment and air purification (odor removal). Reject water usually is returned to the main sewage treatment, which has a negative impact, especially on the sewage treatment systems based on the sequence batch reactors (SBR). Applying high-performance and expensive separate reject water treatment methods such as SHARON, Anammox or CANON in small facilities is not justified economically. The article presents the research results concerning the effectiveness of applying subsurface vertical flow constructed wetlands (SS VF) for reject water treatment from the ATAD process. An innovative type of bed filling was used, which was produced from waste (ash from a heat and power plant). The efficiency of reject water treatment during the research period was on average at 45.6% for ammonia nitrogen, 32.3% for total phosphorus and 85.1% for BOD5. Applying SS VF beds for separate reject water treatment might ensure a stable and effective functioning of municipal WWTPs by decreasing the load of biological part of a WWTP.
Źródło:
Journal of Ecological Engineering; 2018, 19, 4; 103-110
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies