Tytuł:
Energy balancing in modular multilevel converter systems
Autorzy:
Blaszczyk, P.
Koska, K.
Klimczak, P.
Powiązania:
https://bibliotekanauki.pl/articles/201814.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
MMC
multilevel converters
energy balancing
control of power
electronic converters
konwerter
bilans energetyczny
sterowanie elektroniczne
konwerter mocy
Opis:
The modular multilevel converter (MMC) is a well-known solution for medium and high voltage high power converter systems. This paper deals with energy balancing of MMCs. The analysis includes multi-converter systems. In order to provide clear view, the MMC control system is divided into hierarchical levels. Details of control and balancing methods are discussed for each level separately. Finally, experimental results, based on multi-converter test setup, are presented.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2017, 65, 5; 685-694
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Precyzyjny konwerter czasowo-cyfrowy wykorzystujący metodę skracania impulsu zrealizowany w układzie FPGA
Precise time-to-digital converter based on pulse-shrinking implemented in FPGA device
Autorzy:
Szplet, R.
Klepacki, K.
Powiązania:
https://bibliotekanauki.pl/articles/155687.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
precyzyjna metrologia czasu
konwerter czas-liczba
skracanie impulsu
precise time metrology
time-to-digital converter
pulse-shrinking
Opis:
W artykule przedstawione są projekt i wyniki badań konwertera czas-liczba o rozdzielczości 75 ps i zakresie pomiarowym 5.5 ns. Konwerter został zrealizowany w układzie programowalnym Spartan3 firmy Xilinx. Do konwersji czasowo-cyfrowej zastosowano metodę skracania impulsu. W konwerterze wykorzystano cyfrowy detektor zboczy impulsu, który umożliwia kontrolowanie wartości rozdzielczości i uniezależnia mierzony czas trwania impulsu od niekorzystnego wpływu linii transmisyjnych i programowalnych matryc połączeniowych.
This paper describes design and test results of the time-to-digital converter with 75 ps resolution and 5.5 ns measurement range. The converter is implemented in a single programmable device from family Spartan3 (Xilinx). The pulse-shrinking method is used for time-to-digital conversion. Digital pulse-edges detector is applied to control of the conversion resolution and to do measured width time of pulse independent from disadvantageous influence of transmission lines and programmable switch matrixes.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 7, 7; 21-23
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wysokorozdzielczy konwerter czasowo-cyfrowy z próbkowaniem impulsu
A high resolution time-to-digital converter based on pulse sampling
Autorzy:
Szplet, R.
Jarzyński, S.
Powiązania:
https://bibliotekanauki.pl/articles/153993.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
precyzyjna metrologia czasu
konwerter czas-liczba
metoda próbkowania
zegar wielofazowy
układy FPGA
precise time metrology
time-to-digital converter
sampling method
multiphase clock
FPGA devices
Opis:
W artykule opisane są projekt i wyniki badań konwertera czasowo-cyfrowego o rozdzielczości 9 ps i niepewności pomiarowej nie przekraczającej 31 ps. Konwerter został zrealizowany w układzie programowalnym Cyclone firmy Altera. Do konwersji czasowo-cyfrowej użyto nowatorskiej metody, w której informacja o mierzonym odcinku czasu zawarta jest w szerokości impulsu, propagującego się wielokrotnie w zamkniętej pętli opóźniającej i próbkowanego z użyciem wielofazowego zegara o wysokiej częstotliwości. Sterowanie procesem pomiarowym oraz obliczanie i przetwarzanie wyników pomiarów odbywa się z wykorzystaniem dedykowanego interfejsu użytkownika opracowanego w języku C++.W artykule opisane są projekt i wyniki badań konwertera czasowo-cyfrowego o rozdzielczości 9 ps i niepewności pomiarowej nie przekraczającej 31 ps. Konwerter został zrealizowany w układzie programowalnym Cyclone firmy Altera. Do konwersji czasowo-cyfrowej użyto nowatorskiej metody, w której informacja o mierzonym odcinku czasu zawarta jest w szerokości impulsu, propagującego się wielokrotnie w zamkniętej pętli opóźniającej i próbkowanego z użyciem wielofazowego zegara o wysokiej częstotliwości. Sterowanie procesem pomiarowym oraz obliczanie i przetwarzanie wyników pomiarów odbywa się z wykorzystaniem dedykowanego interfejsu użytkownika opracowanego w języku C++.
The paper describes the design and test results of a time-to-digital converter with 9 ps resolution and measurement uncertainty below 31 ps. The converter has been implemented in a programmable device Cyclone manufactured by Altera. The time-to-digital conversion is based on sampling of a periodic square signal. Information about the measured time interval is contained in the width of a pulse that circulates in a closed delay loop and is sampled with the use of a high frequency clock. This method is innovative in the kind of application and it has not been implemented in an integrated circuit so far. In order to achieve both high resolution and high measurement uncertainty the four-phase sampling clock has been used. Such solution allows for fourfold reduction in a number of cycles in the loop and consequently to diminish the measurement error significantly. The four-phase clock has been generated with an embedded PLL functional block. An issue of fundamental importance for the successful implementation of the converter was the use of two short pulses as a representation of the begin and the end of a measured time interval instead of a single long-width pulse. In this way an unpredictable shrinking or stretching of a measured time interval by elements of the delay loop that have different propagation times for rising and falling edges has been avoided. The measurement as well as calculation and processing of obtained results are controlled with the use of dedicated user interface worked out in C++.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 8, 8; 642-644
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowa koncepcja zintegrowanych fotodetektorów półprzewodnikowych
A new concept of integrated semiconductor photodetectors
Autorzy:
Gilewski, M.
Grodzki, L.
Powiązania:
https://bibliotekanauki.pl/articles/160045.pdf
Data publikacji:
2006
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
promieniowanie optyczne
konwerter
fotoelement
Opis:
Stosowane obecnie konstrukcje torów pomiarowych promieniowania optycznego zawierają fotodetektory, najczęściej fotodiody półprzewodnikowe w postaci matrycy elementów. W artykule omówiono parametry konwerterów światło-częstotliwość TSL235R, TSL238. Podano charakterystyki czułości widmowej i zależność częstotliwości wyjściowej od temperatury pracy konwertera.
Designs of measurement chains of optical radiation, used at present include photodetectors, semiconductor photodiodes, in the form of matrices of elements. The paper discusses parameters of the TSL235R and TSL238 light-to-frequency converters. Spectral sensitivity responses and dependence of output frequency on converter operation temperature are presented.
Źródło:
Prace Instytutu Elektrotechniki; 2006, 228; 147-154
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Using braking resistor to improve the performance of neutral point clamped and parallel interleaved DFIG converters
Autorzy:
Okedu, Kenneth
Powiązania:
https://bibliotekanauki.pl/articles/41189302.pdf
Data publikacji:
2023
Wydawca:
Politechnika Warszawska, Instytut Techniki Cieplnej
Tematy:
renewable energy
DFIG
power converters
grid fault
multilevel converters
energia odnawialna
konwerter mocy
usterka sieci
konwerter wielopoziomowy
Opis:
Recently, the use of multilevel converters is on the rise for medium and high voltage applications. Multilevel Converters (MLCs) have the merit of clamping the voltages thereby preventing the need for fast switching, in addition to providing cleaner output waveform for effective switching. As wind turbines are increasing in power ratings, MLCs could be well suited in regards to this application. This paper investigates the performance of a Neutral Point Clamped three-level converter system and a two-level parallel interleaved MLC system in a DFIG variable speed wind turbine during transient. The space vector modulations, switching sequences and strategies of both MLCs were analyzed. The DFIG-based wind turbine system was subjected to a severe grid fault to test the strength of both MLC systems. Furthermore a braking resistor connected to the stator of the DFIG was used to improve the performance of both MLC system. Simulations were run using Power System Computer Aided Design and Electromagnetic Transient Including DC platform. Results obtained using both MLCs were compared based on the performance index of some of the DFIG variables. Also, the responses of the MLCs were compared to the traditional two level DFIG converter topology.
Źródło:
Journal of Power Technologies; 2023, 103, 3; 159-172
1425-1353
Pojawia się w:
Journal of Power Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Scalony konwerter czas-liczba z użyciem metody licznikowej i zegara wielofazowego
Integrated time-to-digital converter with the use of the counter method and a multiphase clock
Autorzy:
Szplet, R.
Gołaszewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/156312.pdf
Data publikacji:
2008
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
precyzyjna metrologia czasu
konwerter czas-liczba
metoda licznikowa
zegar wielofazowy
układy FPGA
precise time metrology
time-to-digital converter
counter method
multiphase clock
FPGA devices
Opis:
W artykule przedstawione są projekt i wyniki badań konwertera czas-liczba o rozdzielczości 78 ps i niepewności pomiarowej poniżej 100 ps. Pomiar czasu realizowany jest z użyciem 32 liczników zliczających okresy szesnastofazowego zegara o częstotliwości 400 MHz. Ponieważ aktywne są obydwa zbocza zegara jest on równoważny pojedynczemu sygnałowi zegarowemu o częstotliwości 12.8 GHz, co umożliwia osiągnięcie średniej rozdzielczości ok. 78 ps przy interpolacji jednostopniowej. Budowa opisanego konwertera czasliczba pozwala na łatwe rozszerzanie zakresu pomiarowego, wynoszącego 164 žs, poprzez zwiększanie pojemności użytych liczników dwójkowych. Sterowanie procesem pomiarowym oraz wyznaczanie i przetwarzanie wyników pomiarów odbywa się z użyciem dwóch procesorów programowych NIOS II zintegrowanych z konwerterem w układzie programowalnym Stratix II firmy Altera.
This paper describes design and test results of the time-to-digital converter with 78 ps resolution and accuracy below 100 ps. The time interval measurement is performed with the use of 32 binary counters counting periods of 16-phase clock of the 400 MHz frequency. Since both edges of the clock are active it is an equivalent of a single clock signal of 12.8 GHz frequency, which provides a mean resolution of about 78 ps in a single interpolation stage. The structure of the converter allows to extend its measurement range (164 žs) easily by increasing the capacity of used binary counters. The measurement as well as calculation and processing of obtained results are controlled by two soft-core processors NIOS II implemented together with the converter in a single programmable device from family Stratix II (Altera).
Źródło:
Pomiary Automatyka Kontrola; 2008, R. 54, nr 8, 8; 591-593
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mathematical model and analysis of single-leg matrix converter
Autorzy:
Dobrucký, B.
Stefanec, P.
Szychta, E.
Spanik, P.
Powiązania:
https://bibliotekanauki.pl/articles/253681.pdf
Data publikacji:
2015
Wydawca:
Instytut Naukowo-Wydawniczy TTS
Tematy:
single-phase supplied
single-leg matrix converter
konwerter matryc jednopiętrowy
Opis:
The paper deals with analysis and modelling of a new type of single-phase supplied AC/AC converter with two phase outputs. It consists of single-leg half-bridge matrix converter loaded by resistive-inductive load in series connection. There are two problems solved in the paper: a) creating of second output phase shifted by 90 degrees against original one, and b) providing of frequency control of both orthogonal phase systems able supplying a two-phase electrical machine. As simulation results are given: harmonic analysis of the voltage of both phases; maximal possible reachable current waveform under R-L load with parametric changes of the time constant of the load. The simulation is resulting to recommendation for fair and right design of the converter, and demands to single- or two phase input supply voltage, respectively, under passive R-L or motoric load.
Źródło:
TTS Technika Transportu Szynowego; 2015, 12; 410-414, CD
1232-3829
2543-5728
Pojawia się w:
TTS Technika Transportu Szynowego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cascaded multilevel converters in recent research and applications
Autorzy:
Malinowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/199898.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
multilevel converters
cascaded converters
modular multilevel converter
modulation
solid state transformer
photovoltaic systems
konwerter
przetwornica
modulacja
transformator
systemy fotowoltaiczne
Opis:
Multilevel converters have been intensively investigated and developed since 1960s and have found successful industrial applications. The aim of this paper is to present state of the art as well as recent research and applications of cascaded multilevel converters, which are a very interesting solution for power distribution systems and renewable energy sources. Cascaded multilevel converters can easily operate at medium and high voltage based on the series connection of power modules (cells), which use standard low-voltage component configurations. Series connections of modules (cells) allow for high quality output voltages and input currents, reduction of passive components and availability of component redundancy. Due to these features the cascaded multilevel converters have been recognized as attractive solutions for high-voltage direct-current (HVDC) transmission, solid state transformers (SST) and photovoltaic (PV) systems.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2017, 65, 5; 567-578
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Model predictive control of multilevel cascaded converter with boosting capability – experimental results
Autorzy:
Wiatr, P.
Kryński, A.
Powiązania:
https://bibliotekanauki.pl/articles/200458.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cascaded H-bridge
CHB
model predictive control
MPC
multilevel converters
mostek H
konwerter
Opis:
The main goal of this paper is to present a five-level converter with the feature of output voltage boosting capability. Thanks to its modular construction and single DC source usage, 5LCHB converter becomes an important alternative for two-level converters operating with DC-DC converters that use bulky inductors. Furthermore, model predictive control (MPC) method is presented, which allows for boosting output voltage of presented converter while providing three-phase load current control and flying capacitor voltage stabilization. The last section describes a 5kVA laboratory model of five-level hybrid converter interfacing RL load and shows experimental results confirming theoretical analysis derived in previous sections.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2017, 65, 5; 589-599
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elektroniczne niemostkowe układy przetwarzania rezystancji i konduktancji na sygnał cyfrowy
The Electronic Non-bridge Circuits for Conversion Resistance and Conductance to the Digital Signal
Autorzy:
Korytkowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/277867.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
sterowane źródło napięcia
sterowane źródło prądu
wzmacniacz monolityczny
monolityczny przetwornik analogowo-cyfrowy
konwerter rezystancji na sygnał cyfrowy
konwerter konduktancji na sygnał cyfrowy
controlled voltage source
controlled current source
monolithic amplifier
monolithic analogue-digital converter
resistance to digital signal converter
conductance to digital signal converter
Opis:
W artykule przedstawiono elektryczne schematy układów konwersji pojedynczej rezystancji i pojedynczej konduktancji na sygnał cyfrowy, możliwe do realizacji przy wykorzystaniu wzmacniaczy monolitycznych oraz przetworników analogowo-cyfrowych. Zaproponowano symbole elementów elektrycznych sterowanych źródeł napięcia i sterowanych źródeł prądu, a także sterowanego napięciowo przetwornika analogowo-cyfrowego. Są to niezbędne elementy elektryczne do tworzenia pełnych końcowych schematów konwerterów rezystancji na sygnał cyfrowy i konwerterów konduktancji na sygnał cyfrowy. Wykazano, że są tylko cztery proste podstawowe schematy tych konwerterów. Omówiono kilka przykładowych schematów elektronicznych układów realizujących funkcje sterowanych źródeł napięcia i sterowanego źródła prądu umożliwiających tworzenie pełnych końcowych schematów elektronicznych konwerterów pojedynczej rezystancji na sygnał cyfrowy i konwerterów pojedynczej konduktancji na sygnał cyfrowy.
The object of paper is description the electronic circuit for conversion the resistance and the conductance to digital signal with using the monolithic amplifies and the monolithic analogue-digital converter. There are shown the electric element symbols of the signal controlled voltage sources and the signal controlled current sources and also the voltage controlled analogue-digital converter, the basic electric elements for construction the schemes of the resistance to digital signal converters and the conductance to digital signal converters. There are only four basic schemes of that converters shown on figures. The paper describes the examples of realization the signal controlled voltage sources and signal controlled current source as the basic elements for construction electronic schemes of the resistance to digital converters and schemes of the conductance to digital converters.
Źródło:
Pomiary Automatyka Robotyka; 2016, 20, 1; 47-55
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Simplified Connection of HEV AC/AC Powertrain
Autorzy:
Dobrucký, B.
Drgoňa, P.
Kaščák, S.
Praženica, M.
Pavlásek, P.
Powiązania:
https://bibliotekanauki.pl/articles/314458.pdf
Data publikacji:
2018
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
hybrid vehicle
converter
powertrain
simulation tests
pojazd hybrydowy
konwerter
układ napędowy
badania symulacyjne
Opis:
The paper deals with a simplified configuration of series HEV hybrid vehicles. Simplification consists of the downsizing of auxiliary 4QC converter needed for hybrid operational modes. Besides, operation in autonomous traction accu-battery modes uses direct 0x5 configuration of traction 3x5 McX matrix converter. Such a configuration can be derived from that main traction converter. Major advantages of simplified connection are beside smaller 4QC converter size – possible little bit better efficiency of the HEV powertrain. Chosen operational modes of modelling and simulation of traction powertrain configuration are focused on start-up and traction drive of HEV powered by ICE, start-up of ICE powered by AB accu-battery using SG as a starter, and traction drive powered by AB accu-battery and braking of traction motor moving energy into accu-battery AB. The results of all simulation experiments are given in the paper.
Artykuł dotyczy uproszczonej konfiguracji pojazdów hybrydowych HEV. Uproszczenie polega na zmniejszeniu konwertera 4QC wymaganego w trybach hybrydowych. Poza tym tryb pracy w trybie autonomicznej trakcji w trybie akumulatorowym wykorzystuje bezpośrednią konfigurację 0x5 trakcyjnego konwertera macierzy 3x5 McX. Taka konfiguracja może być uzyskana z tego głównego konwertera trakcyjnego. Głównymi zaletami uproszczonego połączenia jest mniejsza wielkość konwertera 4QC - możliwa nieco lepsza wydajność układu napędowego HEV. Dostępne są tryby pracy, modelowanie i układ napędowy układu napędowego skoncentrowany na rozruchu i napędzie trakcyjnym HEV napędzanego przez ICE, rozruch ICE zasilany akumulatorem AB z wykorzystaniem SG jako rozrusznika i napęd trakcyjny zasilany przez AB accu - bateria i hamowanie silnika trakcyjnego, które przenosi energię do akumulatora AB. Wyniki wszystkich eksperymentów symulacyjnych podano w pracy.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2018, 19, 6; 831-834, CD
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A design of an acoustic coupler for calibration of hydrophones at low frequencies
Autorzy:
Listewnik, Karol
Powiązania:
https://bibliotekanauki.pl/articles/128000.pdf
Data publikacji:
2019
Wydawca:
Politechnika Poznańska. Instytut Mechaniki Stosowanej
Tematy:
acoustic coupler
calibration of hydrophone
low frequencies
receiving sensitivity
konwerter akustyczny
kalibracja hydrofonu
niskie częstotliwości
czułość odbiorcza
Opis:
The purpose of this article is to present a coupler developed for the calibration of hydrophones at low frequencies in the Central Office of Measures (GUM). Due to the growing demand for marine environment research in the field of underwater noise, implemented in accordance with Directive 2008/56/EC, many models of autonomous underwater noise recorders have been developed. Ensuring the reliability of recorded data begins with the reliable calibration of hydrophones and/or the entire recorder. The choice of the calibration method was made on the basis of a detailed and broad analysis of calibration methods and similar solutions of coupling constructs worldwide. The analysis mainly took into account the documents of the last few years. On the basis of this analysis, the vibrating water column method was chosen and the construction of the coupler was developed. Regular calibration of hydrophones will contribute to reliable underwater noise monitoring in the Baltic region.
Źródło:
Vibrations in Physical Systems; 2019, 30, 1; 1-8
0860-6897
Pojawia się w:
Vibrations in Physical Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of transient states in step-down power converter (BUCK) in continuous and discontinuous conduction mode
Autorzy:
Janke, W.
Walczak, M.
Powiązania:
https://bibliotekanauki.pl/articles/200450.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
step-down converter
BUCK
transient states
CCM
DCM
step-down konwerter
stany przejściowe
Opis:
The object of this paper is a step-down (BUCK) power converter working in the continuous conduction mode (CCM) or discontinuous conduction mode (DCM). Two types of transient states in a converter have been analyzed and observed experimentally: slow transients, described by averaged models of a converter and fast transients, in the course of a single switching period. The averaged models of converter working in CCM, presented in various sources are similar, with some differences concerning only the description of parasitic effects. The averaged models for DCM depend on the adopted modeling method. Models obtained by the switch averaging approach are second-order models (containing two reactive elements in equivalent circuit representation). Models obtained by the separation of variables approach are first-order models. The experimental results given in this paper show the first-order type of transients. Another group of experiments concern fast transients in the course of a single switching period. The oscillations of inductor voltage in the part of a switching period are observed for DCM.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2014, 62, 4; 773-778
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Konwerter TBA20-IŁ do siłowni telekomunikacyjnej
TBA20-IŁ converter for a telecommunication power plant
Autorzy:
Godlewski, P.
Kunert, T.
Powiązania:
https://bibliotekanauki.pl/articles/317512.pdf
Data publikacji:
2004
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
siłownie telekomunikacyjne
utrzymanie akumulatorów
rozładowywanie akumulatorów
telecommunication power plants
battery maintenance
discharge of batteries
Opis:
Zaprezentowano konwerter TBA20-IŁ opracowany w Instytucie Łączności. Jest to urządzenie, które umożliwia automatyczne okresowe kontrolne rozładowywanie i ładowanie akumulatorów zarówno ołowiowych, jak i kadmowo-niklowych zainstalowanych w siłowniach telekomunikacyjnych prądu stałego.
TBA20-IŁ converter developed by the National Institute of Telecommunications has been presented. With this equipment it is possible to discharge and charge automatically, periodically, batteries both of lead-acid and nickel-cadmium type that are installed in direct current telecommunication power plants.
Źródło:
Telekomunikacja i Techniki Informacyjne; 2004, 1-2; 87-93
1640-1549
1899-8933
Pojawia się w:
Telekomunikacja i Techniki Informacyjne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Układ scalony do pomiaru czasu w przepływomierzu ultradźwiękowym
Time measuring circuit for ultrasonic flow-meter
Autorzy:
Zaworski, Ł.
Czoków, J.
Wydźgowski, L.
Powiązania:
https://bibliotekanauki.pl/articles/152190.pdf
Data publikacji:
2008
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
przepływomierz ultradźwiękowy
konwerter czas-cyfra
metrologia czasu
ultrasonic flowmeter
time-to-digital converter
Opis:
Jedną z zasadniczych części przepływomierza ultradźwiękowego jest układ elektroniczny mierzący czas przejścia impulsu pomiędzy przetwornikami ultradźwiękowymi. Minimalna wartość mierzonego strumienia przepływu zależy od rozdzielczości pomiaru czasu. W referacie przedstawiono metody pomiaru czasu w przepływomierzach ultradźwiękowych wykorzystujących metodę pomiaru odcinka czasowego. W szczególności przedstawiono koncepcję układu scalonego CMOS dedykowanego do pomiaru czasu w przepływomierzach ultradźwiękowych, mających zastosowanie w pomiarach małych strumieni przepływu.
One of a most important parts of ultrasonic flowmeter is electronic circuit, which measures transit time of the ultrasonic signals. Minimal value of measured flow rate depends on resolution of time-to-digital converter. In this paper methods of time-interval measurement in ultrasonic flowmeter are described. Implementation of chosen method in CMOS technology is discussed. Expected quantization error of time-to-digital converter is 174 ps and expected resolution of transit - time measurement using sing-around method is 15 ps.
Źródło:
Pomiary Automatyka Kontrola; 2008, R. 54, nr 6, 6; 383-385
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies