Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "impact on power" wg kryterium: Wszystkie pola


Tytuł:
‘Empowerment in Practice and Its Impact on Political Participation’: A Study Among Working Women of South Kolkata
Autorzy:
Chatterjee, Anasua
Powiązania:
https://bibliotekanauki.pl/articles/2194835.pdf
Data publikacji:
2020-12-30
Wydawca:
Uniwersytet im. Adama Mickiewicza w Poznaniu
Tematy:
women
empowerment
decisionmaking power
civil society
political participation
partisan preference
Opis:
The main purpose of the present study is to understand ‘empowerment’ as observed in theory and in actual practice in the society where women are still regarded as second-class citizens inspite of achieving success in their chosen fields. Her freedom in choice of decision-making within the family and civil society plays an important part in influencing her participation in politics and her voting behaviour. By political activism of the respondent we primarily mean her cognitive orientation (i.e. her knowledge about political parties, symbols, their stay in power and their judgements about political system), evaluative orientation on how political system works including her voting behaviour and partisan preference. Survey was carried by the researcher on 1000 women working in both the organised and unorganised sectors of the economy mainly among street vendors and domestic workers and bank employees and teachers in Kolkata. Results: Women working in both the sectors play dual role looking after their children, elders in the family, husbands and also contribute to the  expenditure but lack effective power in decision-making. They consult their husbands, elder members of the family or the community before casting their vote and are notguided by individual preference or choice.
Źródło:
Kultura-Społeczeństwo-Edukacja; 2020, 18, 2; 187-206
2300-0422
Pojawia się w:
Kultura-Społeczeństwo-Edukacja
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Study of the Impact of Power Supply Parameters on Metal Flow Velocity in the Channel of a Device for Washing out Precious Metals from of the Automotive Catalytic Converters
Badanie wpływu parametrów zasilania na prędkość przepływu metalu w kanale urządzenia do wypłukiwania metali szlachetnych z katalizatorów samochodowych
Autorzy:
Fornalczyk, A.
Golak, S.
Przyłucki, R.
Willner, J.
Powiązania:
https://bibliotekanauki.pl/articles/354082.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
PGM recovery
HHD pump
metal-collector method
odzyskiwanie metali
pompa
metoda metal-zbieracz
Opis:
The lifetime of a catalytic converters is limited. Today’s environmental regulations require that used converters should be properly recycled as a valuable source of precious metals, Al2O3 and steel scrap. The precious metals used in the devices perform catalytic functions. They are suspended in a ceramic or metal carrier. This paper deals with the recovery of precious metals from automotive converters using a metal-collector method. In order to speed up the washout of the precious metals from the capillary structure of the converter, the movement of the liquid metal-collector was forced by the electromagnetic field. The research was aimed at improving the effective velocity of the liquid metal flow through the carrier by means of a device with a double windings. Various ways of power supply were considered. The calculation experiment was performed as a weakly coupled analysis of the electromagnetic field and flow field.
Czas życia katalizatorów samochodowych jest ograniczony. Dzisiejsze przepisy środowiskowe wymagają aby były one poddawane procesowi recyklingu jako cenne źródło platynowców, AI2O3 i złomu stalowego. Metale szlachetne stosowane w tych urządzeniach pełnią funkcje katalityczne, naniesione są na ceramiczny lub metalowy nośnik. Artykuł ten dotyczy procesu odzyskiwania metali szlachetnych ze zużytych katalizatorów samochodowych przy wykorzystaniu metody metalu-zbieracza. W celu przyspieszenia procesu wymywania metali szlachetnych ze struktury kapilarnej katalizatora, przepływ ciekłego metalu-zbieracza zmuszony został przez pole elektromagnetyczne. W pracy przedstawiono wyniki modelowania mające na celu poprawę skuteczności przepływu ciekłego metalu przez nośniki katalizatora za pomocą urządzenia z podwójnym uzwojeniem. Przeanalizowano także różne sposoby zasilania urządzenia. Eksperyment obliczeniowy został zrealizowany jako słabosprzężona analiza pola elektromagnetycznego i pola przepływu.
Źródło:
Archives of Metallurgy and Materials; 2014, 59, 2; 779-783
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Algorytm nigdy nie mruga. Wpływ algorytmu zarządzającego portalem YouTube na rzeczywistość społeczną
The algorithm never blinks. The impact of the YouTube algorithm on social reality
Autorzy:
Kosińska, Olga
Powiązania:
https://bibliotekanauki.pl/articles/1856739.pdf
Data publikacji:
2019
Wydawca:
Narodowe Centrum Kultury
Tematy:
youtube
algorytm
tożsamość
władza
kontrola
algorithm
identity
power
control
Opis:
With the ever-growing importance of images in modern times, online visibility management systems, such as the YouTube content organizing algorithm, have a significant influence on social reality. While it is necessary to ensure the proper functioning of the website, the scope of its power and the way in which it is exercised inspire a lot of controversy. By deciding what is to be promoted to the users or removed from their sight, it also has an impact on such seemingly unrelated concepts as “power”, “knowledge”, “authority” or “identity”.
Źródło:
Kultura Współczesna. Teoria. Interpretacje. Praktyka; 2019, 104, 1; 99-111
1230-4808
Pojawia się w:
Kultura Współczesna. Teoria. Interpretacje. Praktyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza oddziaływania odbiorników na jakość energii – możliwości badawcze PTIwIE
Analysis of the impact of receivers on electric power quality – research opportunities of PTIwIE
Autorzy:
BARTMAN, Jacek
KOZIOROWSKA, Anna
Powiązania:
https://bibliotekanauki.pl/articles/455862.pdf
Data publikacji:
2014
Wydawca:
Uniwersytet Rzeszowski
Tematy:
jakość energii
oddziaływanie odbiorników nieliniowych
power quality
the impact of non-linear receivers
Opis:
Wpływ nieliniowych odbiorników energii na jej jakość jest zagadnieniem bardzo aktualnym i szeroko dyskutowanym w literaturze. Autorzy większości opracowań swoje prace badawcze prowadzą analizując wpływ odbiorników na sieć energetyczną i koncentrując się na samej jakości energii. Przedstawione w pracy stanowiska laboratoryjne umożliwią badanie wpływu konkretnych urządzeń nieliniowych na sygnały napięciowe i prądowe oraz pozwolą zebrać materiał do weryfikacji modeli matematycznych tychże urządzeń.
The influence of non-linear receiver of energy to its quality is very actual and widely discussed issue in the literature. The authors of most of research studies analyzing the impact of electrical receiver to the electricity quality and focusing mainly on the quality of energy. Discussed laboratory positions will allow examination of the impact of specific nonlinear devices for voltage and current signals and to gather material for the verification of mathematical models of these devices
Źródło:
Edukacja-Technika-Informatyka; 2014, 5, 1; 573-580
2080-9069
Pojawia się w:
Edukacja-Technika-Informatyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza oddziaływania stopnia zawilgocenia oraz temperatury na parametry schematu zastępczego izolacji papierowo-olejowej wyznaczonego w oparciu o model Cola-Cola
Analysis of the impact of the degree of moisture and temperature on the parameters substitute schema paper-oil insulation on the basis of the Cole-Cole model
Autorzy:
Wolny, S.
Adamowicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/158804.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
izolacja papierowo-olejowa
spektroskopia częstotliwościowa dielektryków
model Cola-Cola
transformatory energetyczne
paper-oil insulation
frequency dielectric spectroscopy
Cole-Cole model
power transformers
Opis:
Transformatory dużej mocy należą do najważniejszej grupy urządzeń układów sieci elektroenergetycznych, których stan izolacji papierowo-olejowej transformatora w bardzo dużym stopniu decyduje o ich prawidłowej pracy. Pomimo rozwoju produkcji nowych materiałów elektroizolacyjnych, np. papierów syntetycznych, nadal w większości urządzeń dominuje izolacja oparta na bazie celulozy w połączeniu z olejem mineralnym. Obecnie metody diagnozowania stanu izolacji pozwalają przedsiębiorstwom energetycznym bezpiecznie wydłużać czas eksploatacji transformatorów energetycznych przy akceptowalnie niskim ryzyku wystąpienia awarii. W artykule opisano jedną z metod wykorzystywanych w diagnostyce izolacji papierowo–olejowej, tzn. spektroskopię częstotliwościową dielektryków – określoną skrótem FDS (Frequency Dielectric Spectroscopy). Na podstawie uzyskanych pomiarów obliczono wartości parametrów modelu Cola-Cola (εs, ε∞, α, τ). Przedstawiono możliwość wykorzystania parametrów modelu Cola-Cola, pod kątem ich przydatności do symulacji oddziaływania stopnia zawilgocenia oraz temperatury na parametry schematu zastępczego izolacji papierowo-olejowej.
Transformers belong to the most important group of devices of power networks systems the state of paper-oil insulated transformer to a large extent decides their correct operation. Despite the development of production of new materials, electrical insulation, for example, synthetic papers, most devices still dominate the insulation based on cellulose in combination with mineral oil. Currently, methods for diagnosis of insulation allow energy companies to safely extend the life of power transformers at acceptably low risk of failure.The article describes one of the methods used in the diagnosis insulation paper-oil, ie frequency dielectric spectroscopy – defined abbreviation FDS (Frequency Dielectric Spectroscopy). Based on the measurements was calculated parameters of the Cole-Cole model (εs, ε∞, α, τ). Presents the possibility of using Cole-Cole model parameters, under their suitability to simulate the impact of the degree of moisture and temperature the substitute schema parameters insulation of paper and oil.
Źródło:
Prace Instytutu Elektrotechniki; 2012, 259; 107-108
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu długości linii elektroenergetycznej SN na pochodzące od prądów odkształconych jednostkowe straty mocy czynnej
Analysis the impact of length the medium power transmission line on the unitary active power losses derived from distorted currents
Autorzy:
Plikunas, E.
Powiązania:
https://bibliotekanauki.pl/articles/377411.pdf
Data publikacji:
2017
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
straty mocy czynnej
wyższe harmoniczne
linie średniego napięcia
Opis:
W referacie podjęto dyskusję nad wpływem budowy linii elektroenergetycznej SN na jednostkowe straty mocy czynnej w liniach SN, wywołane przepływem prądów odkształconych, pochodzących od odbiorców wiejskich. Analizie poddano linię SN zasilającą stację transformatorową SN/nn, do której przyłączony jest odbiorca wpływający na jakość energii elektrycznej, wprowadzający do sieci prądy elektryczne wyższych harmonicznych. Modelowany w programie symulacyjnym fragment rozpatrywanego systemu elektroenergetycznego, analizowany w dziedzinie częstotliwości, wykorzystano do numerycznego obliczenia strat mocy czynnej w linii SN o różnej długości, lecz stałych parametrach skupionych.
In the paper was discussed the impact of the construction of a medium voltage power line on unit active power losses in the medium voltage power lines, caused by the flow of distorted currents coming from rural customers. Analysed the medium voltage power line supply transformer station MV/LV, connected with receiver affects the quality of the electricity, introducing to network higher harmonics currents. Modelled in the simulation fragment of the power system, analysed in the frequency domain was used to calculate active power losses in line MV of different length but permanent concentrated parameters.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2017, 90; 255-263
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu Dyrektywy MIFID II na rynek energii elektrycznej w Europie
Analysis of the impact of MiFID II on the electricity market in Europe
Autorzy:
Hawranek, Paweł
Michalski, Dariusz
Powiązania:
https://bibliotekanauki.pl/articles/507832.pdf
Data publikacji:
2015-05-31
Wydawca:
Uniwersytet Warszawski. Wydawnictwo Naukowe Wydziału Zarządzania
Tematy:
MiFID II
EMIR; rynek energii
struktura przedsiębiorstw energetycznych
ryzyko
hedging
prop-trading
EMIR
power market
structure of the power companies
risk
Opis:
W artykule poruszono kwestię wpływu Dyrektywy MiFID II na rynek energii oraz na strukturę przedsiębiorstw elektroenergetycznych. Omówiono także cele tej regulacji, a także wskazano, które z instrumentów szeroko rozumianego rynku energii zostaną objęte nową regulacją oraz przedstawiono wątpliwości i konsekwencje skutków tak ukształtowanego zakresu przedmiotowego regulacji. Poruszono również kwestię zakresu podmiotowego nowej dyrektywy, jej relację do zakresu stosowania rozporządzenia EMIR oraz wynikające z tego konsekwencję dla przedsiębiorstw elektroenergetycznych. Zasygnalizowano także zagadnienia związane z planowanym harmonogramem wdrażania dyrektywy i związane z tym wyzwania dla podmiotów działających na rynku energii.
This paper presents the impact of Directive MiFID II on the energy market and the structure of electricity companies. It also discusses the objectives of the new provisions and indicates which instruments of the energy market are to be covered by the scope of its application. The Authors elaborate on the subjective scope of the new Directive, its relation to the EMIR Regulation, and the consequences resulting from MiFID II for electricity companies. The schedule of the Directive’s implementation is outlined and the associated challenges noted created by MiFID II for the European energy industry.
Źródło:
internetowy Kwartalnik Antymonopolowy i Regulacyjny; 2015, 4, 3; 79-92
2299-5749
Pojawia się w:
internetowy Kwartalnik Antymonopolowy i Regulacyjny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu ładowania pojazdów elektrycznych na dynamikę zmian dobowego obciążenia systemu elektroenergetycznego
Analysis of impact of charging electric cars on dynamics of load changes of the power system
Autorzy:
Stahl, Wiktoria
Bućko, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/266752.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
V2G
G2V
gradient obciążenia
load gradient
Opis:
W artykule dokonano analizy możliwego wpływu ładowania samochodów elektrycznych na dynamikę zmian obciążenia dobowego systemu elektroenergetycznego. Oceniono możliwe zmiany kształt wykresu dobowego, w przypadku gdyby 5% użytkowanych samochodów zastąpić samochodami elektrycznymi. Analizie zostały poddane dwa warianty współpracy samochodów z systemem: G2V (proste ładowanie samochodów) oraz V2G (wykorzystanie możliwości oddawania energii do sieci). W artykule zaprezentowano wpływ samochodów na tzw. gradienty obciążeń, czyli szybkość narastania lub spadku obciążenia na granicach stref czasowych.
In this article there were presented an analysis of the impact of charging electric cars on daily load curve of the power system. There were shown three variants of daily load curve – a curve of actual load, curve that takes into account impact of electric cars by G2V scenario and curve that takes into account impact of electric cars by V2G strategy. As part of analysis, there were calculated and presented values of load gradients. Load gradient is a factor that indicates the dynamics of load changes. There were also shown parts of curves, that were analysed. On graphs there were applied trend lines and its equations. Load gradients were calculated in both ways – as a derivative of trend line equation and as the ratio of load increase to the time in which it lasted. Low values of gradients shows that, the increases (or decreases) of power demand were not sudden and proceeded in a sustainable manner. High values of gradients were not desirable, because it means that power demand increases (or decreases)in sudden and quick way in short time. It is easier for power system to cover power demand that not changes suddenly. Depending on the chosen strategy, there were different values of gradients. Based on calculations, the best for power system is V2G variant. V2G solution guarantees a higher demand during night valley and reduction of peak demands. That means power increases from night valley to morning peak and decreases from evening peak to night valley more fluently. This is shown by low gradients values.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 62; 29-32
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu niesymetrii obciążeń odbiorców wiejskich na jakość energii elektrycznej w linii niskiego napięcia
Analysis of the impact of asymmetric loads of rural subscribers on the quality of electric power in lv lines
Autorzy:
Kolber, P.
Piechocki, J.
Powiązania:
https://bibliotekanauki.pl/articles/287267.pdf
Data publikacji:
2005
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
niesymetria obciążeń
parametry jakościowe
energia elektryczna
asymmetry of loads
quality parameters
electric energy
Opis:
W artykule przedstawiono wpływ stopnia niesymetrii obciążeń odbiorców wiejskich na wartości wybranych parametrów jakościowych energii elektrycznej w linii niskiego napięcia. Zrealizowano to poprzez badania za pomocą programu symulacyjnego wykorzystującego m.in. wyniki pomiarów obciążeń u odbiorców dla linii o ustalonej długości, topografii, przekroju przewodów i wartości pobieranej mocy.
The paper describes how the asymmetry of loads of rural subscribers affects the values of selected electric energy quality indicators in low voltage line. This has been achieved by the study performed with the aid of a simulation program, using, among others, values of load measured on the premises of subscribers using supply line of fixed length, topography, conductors gauge and power drawn.
Źródło:
Inżynieria Rolnicza; 2005, R. 9, nr 6, 6; 345-353
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu stopnia zawilgocenia oraz zestarzenia próbek izolacji aramidowo-olejowej na charakterystyki prądu depolaryzacji
Impact analysis of the degree of moisture and aging samples aramid-oil insulation on the depolarization current characteristics
Autorzy:
Wolny, S.
Lepich, M.
Powiązania:
https://bibliotekanauki.pl/articles/154205.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
transformator mocy
ocena stopnia zawilgocenia
ocena stopnia starzenia
polaryzacja
izolacja aramidowo-olejowa
power transformer
assess the degree of moisture
assess the degree of aging
polarization
oil-aramid insulation
Opis:
W artykule zaprezentowano wyniki badań laboratoryjnych wpływu zestarzenia i zawilgocenia izolacji aramidowo-olejowej na prąd depolaryzacji, z uwzględnieniem oddziaływania temperatury na podstawie bezinwazyjnej metody PDC (Polaryzation and Depolaryzation Current). Ponadto w celu wskazania przydatności zastosowanej metody do oszacowania powyższych wskaźników przedstawiono wyniki badań statystycznych odtwarzalności i powtarzalności wykonanych pomiarów.
Results of laboratory research into the influence of ageing and moistness degree of aramid-oil insulation samples on the depolarisation current considering temperature effects are presented. Also the possibilities to apply the non-invasive PDC (Polarisation and Depolarisation Current) diagnostic method to analyse depolarisation currents of the new type of synthetic insulation based on aramid are described. The method of preparation of samples, which differ – in a controlled manner – as to the moistness and ageing degree, is also described. Because of the resulting high repeatability and reproducibility of obtained measurements, this method seems to be appropriate for the diagnosis of solid insulation of power transformers.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 11, 11; 1006-1009
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu wewnętrznego wymiennika ciepła na moc cieplną górniczych chłodziarek powietrza
The analysis of impact of internal heat exchanger on thermal power of mining air refrigerators
Autorzy:
Życzkowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/349035.pdf
Data publikacji:
2010
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
wewnętrzny wymiennik ciepła
chłodziarki
klimatyzacja
internal heat exchanger
refrigerators
air-conditioning
Opis:
Zastosowanie wewnętrznego wymiennika ciepła (internal heat exchanger - IHX) w układzie chłodniczym pozwala na zwiększenie wydajności chłodniczej urządzeń chłodniczych. W artykule przedstawiono analizę zmian mocy cieplnej i współczynników wydajności chłodniczej górniczych chłodziarek powietrza typu TS-300 oraz TS-450P przez instalację wewnętrznego wymiennika ciepła.
An use of internal heat exchanger (IHX) in refrigerating system allows increasing the refrigerating capacity of refrigerators. The analysis of the changes of thermal power and refrigerating capacity of TS-300 and TS-450P mining refrigerators types with internal heat exchanger were described in this article.
Źródło:
Górnictwo i Geoinżynieria; 2010, 34, 3/1; 187-200
1732-6702
Pojawia się w:
Górnictwo i Geoinżynieria
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu wybranych odnawialnych źródeł energii na straty mocy czynnej i biernej w systemie elektroenergetycznym
Impact of the selected renewable energy sources on active and reactive power losses in a power system
Autorzy:
Tarakan, B.
Tarakan, K.
Zajczyk, R.
Czapp, S.
Sarnicki, M.
Powiązania:
https://bibliotekanauki.pl/articles/266608.pdf
Data publikacji:
2016
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
odnawialne źródła energii
OZE
farma fotowoltaiczna
farmy wiatrowe
straty mocy czynnej
straty mocy biernej
renewable energy sources
photovoltaic farm
wind farms
loss of active power
loss of reactive power
Opis:
Moc zainstalowana oraz produkcja energii elektrycznej z odnawialnych źródeł energii od kilkunastu lat systematycznie w Polsce wzrasta. Należy spodziewać się, że tendencja ta w najbliższych latach zostanie utrzymana. Dość dużym zainteresowaniem cieszą się źródła wiatrowe oraz źródła fotowoltaiczne, co sprawia, że przy znacznych ich mocach zainstalowanych konieczne staje się badanie wpływu tych źródeł na system elektroenergetyczny. W artykule przedstawiono analizę wpływu farmy fotowoltaicznej i farmy wiatrowej na poziom strat mocy czynnej i biernej w systemie elektroenergetycznym. Obliczenia wykonano z wykorzystaniem programu DIgSILENT PowerFactory.
The rated power and the production of energy from renewable energy sources for several years steadily increases in Poland. It is expected that this trend will be continued in the coming years. Wind and photovoltaic sources are very popular and in consequence it becomes necessary to study the impact of these sources on the power system. The article presents an analysis of the impact of photovoltaic farm and wind farm on the level of loss of active and reactive power in the power system. Calculations were performed with the use of DIgSILENT PowerFactory software.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2016, 51; 27-30
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu wybranych profili łopat wirnika na generowaną moc przez mini siłownię wiatrową
Analysis of the impact of the selected profiles of rotor blades on the power generated by mini power wind plant
Autorzy:
Dębowski, M.
Romański, L.
Komarnicki, P.
Bieniek, J.
Powiązania:
https://bibliotekanauki.pl/articles/290747.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
siłownia wiatrowa
energetyka
profil łopaty
wind power plant
power industry
blades profiles
Opis:
W artykule przedstawiono wyniki badań mocy generowanej przez elektrownię wiatrową wyposażaną zamiennie w trzy różne wirniki. Testowanie przeprowadzono na mini siłowni wiatrowej JSW 750-12 produkowanej przez firmę KOMEL. W trakcie badań przeanalizowano pracę wirnika dostarczanego wraz z siłownią oraz dwóch nowych wirników o łopatach dwu profilowych. Do zaprojektowania łopat pierwszego wirnika zastosowano profile z rodziny NACA a w drugim profile z rodziny GOE. Testowanie przeprowadzono w tunelu aerodynamicznym, umożliwiającym analizę pracy siłowni wiatrowej w zakresie prędkości od 5 do 16 m·s-1. Dodatkowo w trakcie badań zmieniano również kąty zaklinowania łopat wirnika. W efekcie wykreślono 15 charakterystyk mocy (moc generowana przez siłownię wiatrową w funkcji prędkości wiatru). Zastosowanie nowych wirnikow silowni umożliwiło generowanie przez mini siłownię wiatrową większych mocy niż przy stosowaniu oryginalnych wirników fabrycznych i to w całym zakresie badanych prędkości wiatru. Efektem dodatkowym badań jest propozycja nowego kierunek badań, który pozwoli usprawnić konstrukcję generatora prądu elektrycznego, a tym samym prowadzić do bezawaryjnej pracy elektrowni wiatrowej.
The article presents the research results of the power generated by the wind power plant equipped interchangeably with three different rotors. Testing was carried out on the mini power wind plant JSW 750-12 produced by KOMEL company. Operation of the rotor provided with the power plant and two new rotors of two-profile blades were analysed during the research. Profiles of NACA family were used for design of the first rotor's blades and GOE family profiles were used for designing the second rotor's blades. Testing was carried out in the aerodynamic tunnel, enabling the wind power plant analysis within the speed of 5 to 16 m·s-1. Additionally, during the research, wedge angles of rotor blades were modified. As a result, 15 characteristics of power were determined (power generated by the wind power plant as a function of wind speed). The use of new rotors of the power plant, enabled wind power plant to generate higher power than at the use of original factory rotors in the whole scope of wind speed. Suggestion of a new research direction, which would allow improvement of electric current generator structure and therefore lead failure-free operation of the electric power plant, is an additional effect.
Źródło:
Inżynieria Rolnicza; 2013, R. 17, nr 3, t. 1, 3, t. 1; 25-34
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the Impact of Charging Electric Cars on the Power System Load
Analiza wpływu ładowania samochodów elektrycznych na obciążenia systemu elektroenergetycznego
Autorzy:
Stahl, Wiktoria Weronika
Bućko, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/952887.pdf
Data publikacji:
2019
Wydawca:
ENERGA
Tematy:
electric power system
electric car
V2G
G2V
system elektroenergetyczny
samochód elektryczny
Opis:
The paper presents ways of integrating electric cars with the power system. In connection with this, daily load curves in the average working day have been developed in the G2V (Grid-to- Vehicle) and V2G (Vehicle-to-Grid) variants. The G2V solution consists in unidirectional energy flow from the power system to a vehicle’s battery. The V2G solution consists in bi-directional energy exchange between the power system and electric car’s battery. Each of these options may have a different impact on the system’s load. The paper presents the impact of charging a large number of electric cars on the dynamics of load changes in the period of increasing demand from the night valley to the morning peak and during its fall from the evening peak to the night valley. Also, indicators characterizing the shape of the daily load curve were analysed. The actual system load curve was compared with the G2V and V2G based on original calculations.
W artykule zaprezentowano sposoby integracji samochodów elektrycznych z systemem elektroenergetycznym. W związku z tym opracowane zostały krzywe obciążenia dobowego średniego dnia roboczego w wariancie G2V (ang. Grid-to-Vehicle) oraz V2G (ang. Vehicle-to-Grid). Rozwiązanie G2V uwzględnia jednokierunkowy przepływ energii z systemu elektroenergetycznego do baterii pojazdu. Rozwiązanie V2G oznacza dwukierunkową wymianę energii pomiędzy systemem a baterią samochodu elektrycznego. Każda z przedstawionych opcji może w inny sposób wpłynąć na kształtowanie się obciążeń systemu. W artykule przedstawiono wpływ ładowania się dużej liczby samochodów elektrycznych na dynamikę zmian obciążenia w okresie zwiększania się zapotrzebowania z doliny nocnej do szczytu porannego oraz podczas jego spadku ze szczytu wieczornego do doliny nocnej. Wykonano również analizę wskaźników charakteryzujących kształt krzywej obciążenia dobowego. Na podstawie przeprowadzonych obliczeń porównano krzywą rzeczywistego obciążenia systemu z wariantami G2V oraz V2G.
Źródło:
Acta Energetica; 2019, 1; 95-101
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Approach to Impact Assessment of the Rated Power Uprate of NPP Unit on the Service Life of the Turbine Critical Elements
Autorzy:
Chernousenko, Olga
Nikulenkova, Tetyana
Peshko, Vitaliy
Nikulenkov, Anatolii
Powiązania:
https://bibliotekanauki.pl/articles/1811575.pdf
Data publikacji:
2020
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
nuclear power plant
reliability
turbine
steam flow
computational fluid dynamics
high pressure rotor
service life
long-term strength
low cycle fatigue
Opis:
Nuclear power plants play an important role in power systems of many countries. Ability to reasonable increase installed capacity of nuclear power units allow to reduce the cost for building of new power plants. When increasing NPP capacity to 104% there is a need to estimate the residual life of plant’s typical elements and continue their operation. The mathematical model of estimation of service life indicators of steam turbine K-1000-60/3000 is developed. The effect of increasing the capacity of a nuclear reactor on the heat transfer coefficients of a steam in the nozzle segments of high-pressure cylinder was established by using CFD modeling. The thermal and stress-strain state of the high-pressure rotor for the most typical operating modes are calculated. Using the correlation dependences of low-cycle fatigue, the rate of accumulation of cyclic damage of the base metal is established. The resistance of the metal to the exhaustion of long-term strength is also determined. On the example of the high pressure rotor of the 3rd power unit of Rivne NPP the service life indicators are calculated. The validity of increasing the installed capacity of the power unit was also confirmed.
Źródło:
Rocznik Ochrona Środowiska; 2020, Tom 22, cz. 1; 105-116
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies