Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "full scale experiment" wg kryterium: Wszystkie pola


Wyświetlanie 1-2 z 2
Tytuł:
Distinctive features of water exchange across the Słupsk Sill (a full-scale experiment)
Autorzy:
Paka, V.
Golenko, N.
Korzh, A.
Powiązania:
https://bibliotekanauki.pl/articles/47795.pdf
Data publikacji:
2006
Wydawca:
Polska Akademia Nauk. Instytut Oceanologii PAN
Tematy:
Sopot
water exchange
thermohaline structure
Slupsk Sill
saline water
conference
Baltic Sea
high-resolution transect
inflow water
brackish water
Opis:
The flows of brackish waters in the upper layer and saline waters in the lower layer meet above the Słupsk Sill, which makes this one of the most significant features of the Baltic Sea, controlling as it does the ventilation of the deep basins in its central region. Earlier high-resolution measurements using towed scanning probes conducted here for more than ten years had revealed the complexity and variability of the water dynamics in this area. Mapping surveys repeated in quick succession are needed to study the water exchange in such an area. A survey of this kind was attempted in October 2003 during the 57th cruise of the r/v ‘Professor Shtokman’. Three surveys were carried out in the areas of the Słupsk Sill, the eastern Bornholm Basin, and the western Słupsk Furrow by means of a scanning probe towed along closely-spaced transects. The water structure around the sill was different each time, despite the rather short time gaps between the surveys. As follows from the data analysis, during the first survey, the saline Bornholm waters flowed over the sill as an axially symmetrical jet and entrained the adjacent freshened cold waters of the intermediate layer. In ten days, this joint flow displaced to the southern flank of the sill and propagated in the Słupsk Furrow along its southern border, with the dense core of saline waters gradually moving over the bottom to the northern border. Concurrently, the contrary flow of the main volume of cold freshened waters, originating from northern areas and leaving the Baltic Sea, was pushed away from the southern wall of the furrow and blocked at a significant distance from the sill. In three days, the blocked waters forced their way through towards its northern flank. Just below these waters, waters of elevated salinity were found above the eastern slope of the sill at the depth of its ridge, while waters of a similar salinity occurred below the depth of the ridge above the western slope of the sill. There were no indications of intensive overflow in the central and southern areas of the sill. Accordingly, the return flow of Bornholm waters across the sill became possible.
Źródło:
Oceanologia; 2006, 48, S
0078-3234
Pojawia się w:
Oceanologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental Study of Flow Characteristics of Mobile Fans under Real Operating Conditions (Case Study)
Badania eksperymentalne charakterystyk przepływowych mobilnych wentylatorów w rzeczywistych warunkach pracy (studium przypadku)
Autorzy:
Kaczmarzyk, Piotr
Noske, Rafał
Janik, Paweł
Krawiec, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/35009181.pdf
Data publikacji:
2022
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
Positive Pressure Ventilator
PPV
mobile fan
full scale experiment
open flow
air flow rate
wentylator nadciśnieniowy
wentylator mobilny
eksperyment na pełną skalę
przepływ otwarty
natężenie przepływu powietrza
Opis:
Aim: The aim of this article is to evaluate the effect of selected positioning parameters of the fan (positioning distance and impeller angle) on the ability to pump a volumetric airflow stream through a construction object. Method design: Mobile fans used during rescue operations are an important tool to reduce the spread of smoke during interior fires in buildings. Due to the nature of the use of these devices, the characteristics that determine their performance should be tested using test methodologies with characteristics similar to their actual conditions of use. The article presents the author's method for studying the volumetric flow rate of air. In addition, a flow resisting curtain (FRC) test stand for determining flow characteristics in real building systems was presented. The flow tests were carried out at a facility with a volume of 282 m3, which is a training room of the Scientific and Research Centre for Fire Protection – National Research Institute. Results: As part of the performed research, the flow characteristics for the mobile fan sample were determined. The completed tests showed that the fan pumped a volumetric flow rate ranging from 2471 to 17997 m3/h. It was determined that the most favourable positioning distance of the tested fan calculated from the inlet opening to the room is 5 meters. At this distance, the highest values of volumetric flow rate were obtained for both studied slope angles – 0 and 8° (recorded values are 17298 and 17997 m3/h, respectively). Conclusions: Proper positioning of the mobile fan has a significant impact on the amount of airflow pumped through the building. The positioning parameters of the mobile unit are, respectively, the mechanism for changing the angle of the air supply and its mobility – the ability to move to another location. This article presents the results of a test of the volumetric flow characteristics of an air jet generated by a mobile fan. The test results showed that the parameters of fan positioning have a significant impact on the effectiveness of tactical mechanical ventilation during rescue operations. Observations made during the tests indicate that it is reasonable to implement requirements for the mandatory use of information boards showing the optimal positioning parameters for mobile units to achieve the highest possible expenditure.
Cel: Celem artykułu jest ocena wpływu wybranych parametrów pozycjonowania wentylatora (odległości ustawienia i kąta nachylenia wirnika) na zdolność do przetłaczania objętościowego strumienia przepływu powietrza przez obiekt budowlany. Projekt metody: Mobilne wentylatory wykorzystywane podczas działań ratowniczych stanowią ważne narzędzie pozwalające ograniczyć rozprzestrzenianie się dymu podczas pożarów wewnętrznych obiektów budowlanych. Z uwagi na charakter wykorzystania tych urządzeń, cechy warunkujące ich skuteczność działania powinny być poddane badaniom z wykorzystaniem metodyk badawczych o charakterystyce zbliżonej do ich rzeczywistych warunków stosowania. W artykule przedstawiono autorską metodę badań objętościowego strumienia przepływu powietrza. Ponadto zaprezentowane zostało stanowisko badawcze FRC (ang. flow resisting curtain) przeznaczone do wyznaczania charakterystyk przepływowych w rzeczywistych układach obiektów budowlanych. Badania przepływowe wykonano na terenie obiektu o kubaturze 282 m3 stanowiącego salę szkoleniową Centrum Naukowo- -Badawczego Ochrony Przeciwpożarowej – Państwowego Instytutu Badawczego. Wyniki: W ramach wykonanych badań określona została charakterystyka przepływowa dla próbki mobilnego wentylatora. W wyniku zrealizowanych testów wykazano, że wentylator przetłoczył objętościowy strumień w zakresie od 2471 do 17997 m3/h. Stwierdzono, że najkorzystniejsza odległość pozycjonowania badanego wentylatora liczona od otworu wlotowego do pomieszczenia wynosi 5 metrów. Przy tej odległości uzyskano największe wartości objętościowego strumienia przepływu dla obu zbadanych kątów nachylenia – 0 i 8° (odnotowane wartości to odpowiednio 17298 i 17997 m3/h). Wnioski: Odpowiednie ustawienie mobilnego wentylatora ma znaczący wpływ na wielkość tłoczonego strumienia powietrza przez obiekt budowlany. Parametrami pozycjonowania mobilnej jednostki są odpowiednio mechanizm zmiany kąta nawiewu oraz jego mobilność – możliwość przeniesienia w inne miejsce. W artykule przedstawiono wyniki badań charakterystyki przepływu objętościowego strugi powietrza generowanej przez mobilny wentylator. Uzyskane rezultaty testów wykazały, że parametry pozycjonowania wentylatora mają znaczący wpływ na efektywność działania taktycznej wentylacji mechanicznej podczas działań ratowniczych. Obserwacje przeprowadzone w trakcie testów wskazują na zasadność wdrożenia wymagań dotyczących obowiązku stosowania tablic informacyjnych przedstawiających optymalne parametry pozycjonowania mobilnych jednostek pozwalające osiągnąć możliwie największy wydatek.
Źródło:
Safety and Fire Technology; 2022, 60, 2; 104-117
2657-8808
2658-0810
Pojawia się w:
Safety and Fire Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies