Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "common mode" wg kryterium: Wszystkie pola


Wyświetlanie 1-20 z 20
Tytuł:
Differential and Common Mode Noise Waves and Correlation Matrices
Autorzy:
Dobrowolski, J. A.
Powiązania:
https://bibliotekanauki.pl/articles/226394.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
differential and common mode noise waves
mixed-mode noise wave correlation matrices
generalized multiport mixed-mode noise wave correlation matrice
Opis:
This paper presents an innovative extention of the noise wave definition to mixed mode, differential – and common-mode noise waves which can be used for noise analysis of differential microwave networks. Mixed mode noise waves are used next to define generalized mixed mode noise wave correlation matrices of microwave multiport networks. Presented approach may be used for noise analysis of microwave differential networks with differential ports as well as with conventional single ended ports.
Źródło:
International Journal of Electronics and Telecommunications; 2014, 60, 2; 133-141
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Common mode behavior in grid connected DC and AC decoupled PV Inverter topologies
Autorzy:
Sundar, D.J.
Kumaran, M.S.
Powiązania:
https://bibliotekanauki.pl/articles/141723.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
distributed generation
common mode leakage current
solar PV systems
transformerless PV inverters
Opis:
The transformer-less grid connected inverters are gaining more popularity due to their high efficiency, very low ground leakage current and economic feasibility especially in photovoltaic systems. The major issue which surfaces these systems is that of common mode leakage current which arises due to the absence of an electrical transformer connected between the inverter and the utility grid. Several topologies have evolved to reduce the impact of common mode leakage current and a majority of them have succeeded in eliminating the impacts and have well kept them within the limits of grid standards. This paper compares and analyses the impact of the common mode leakage current for four popular inverter configurations through simulation of the topologies such as H5, H6, HERIC and FBZVR inverters.
Źródło:
Archives of Electrical Engineering; 2016, 65, 3; 481-493
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Three-level modulation techniques to reduce instantaneous common mode voltage in induction machines
Autorzy:
Cusidó, J.
Luna, A.
Busquets, S.
Bordonau, J.
Rodríguez, P.
Romeral, L.
Powiązania:
https://bibliotekanauki.pl/articles/262817.pdf
Data publikacji:
2007
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
common mode voltages
multilevel inverter
drive systems
Opis:
Problems on inverter motor drives such as bearing currents are introduced due to common mode voltages. Different solutions are proposed on literature, for two-level or multilevel inverter. Instantaneous zero common mode voltage by using a three-level inverted could be achieved. This paper proposes a commutation strategy that allows zero common mode voltage by using medium vectors, and also a new representation as a plane on the commutation space is defined which is called zero common mode voltage plane. On this defined plane, every turning vector fulfil this property. Simulations and experimental results clearly show method's efficiency.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2007, 13, 2; 33-38
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An improved space vector modulation strategy for common-mode voltage reduction in matrix rectifier
Autorzy:
Liu, X.
Zhang, Q.
Hou, D.
Powiązania:
https://bibliotekanauki.pl/articles/950664.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
matrix converter
space vector modulation
common-mode voltage
Opis:
The matrix rectifier modulated by the classical space vector modulation (SVM) strategy generates common-mode voltage (CMV). The high magnitude and high du/dt of the CMV causes serious problems such as motor damage, electromagnetic noise and many others. In this paper, an improved SVM strategy is proposed by replacing the zero vectors with suitable couple of active ones that substantially eliminate the CMV. Theoretical analysis proves that the proposed strategy can reduce the amplitude of the CMV to half of the original value. In addition, the quality of the input and output waveforms is not affected by extra active vectors. Simulation and experimental results demonstrate the feasibility and effectiveness of the proposed strategy are shown.
Źródło:
Archives of Electrical Engineering; 2014, 63, 1; 93-106
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of reducing common mode noise of conducted emission in a switching power converter considering parasitic effects
Autorzy:
Aswini, G. V.
Chenthurpandian, S.
Powiązania:
https://bibliotekanauki.pl/articles/27315702.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Elektryków Polskich
Tematy:
conducted emission
radiated emission
electromagnetic interference
electromagnetic compatibility
EMI filter
Opis:
Most automotive electronic components can cause electromagnetic interference, that can cause power electronic circuits to become unstable. As per electromagnetic compatibility (EMC) standards, these electronic circuits should meet the specifications which are not achieved under some conditions. In this paper, the conducted emissions (CEs) are generated due to the switching of a buck converter, which often occurs in automotive electronics. The noise source was found to be due to the presence of common mode currents which largely affects the performance of EMC. Two types of filtering techniques were analysed and designed, and the results were compared to find an effective filtering solution to mitigate the effects of CE due to a common mode noise for the frequency range from 150 kHz to 108 MHz according to the International Special Committee on Radio Interference (CISPR25) standard. The capacitive and parasitic impedance were calculated and then used in the simulation. Finally, the simulated and measured results are presented. The noise level can be minimized by as much as 50 dB, which is an efficient noise reduction value.
Źródło:
Opto-Electronics Review; 2023, 31, 3; art. no. e147039
1230-3402
Pojawia się w:
Opto-Electronics Review
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ground leakage current caused by Common-Mode Voltage of PWM inverter
Prądy upływu doziemnego generowane napięciem wspólnym falownika MSI
Autorzy:
Szymański, Jerzy Ryszard
Żurek-Mortka, Marta
Powiązania:
https://bibliotekanauki.pl/articles/106701.pdf
Data publikacji:
2019
Wydawca:
Uniwersytet Technologiczno-Humanistyczny im. Kazimierza Pułaskiego w Radomiu
Tematy:
common-mode voltage
differential-mode voltage
PWM modulation
three-phase traction voltage inverter
two-level PWM inverter
dwupoziomowy falownik MSI
napięcie różnicowe
napięcie wspólne
modulacja MSI
trójfazowy trakcyjny falownik napięciowy
Opis:
In railway tractive vehicles, three-phase PWM (Pulse Width Modulation) inverters generate parasitic Differential-Mode Voltages (DMV) and Common-Mode Voltages (CMV). Parasitic voltages are a side effect of using the width modulation to shape the phase-to-phase inverter’s voltage. In this article, the authors present a mathematical description of the DM and CM voltages and carry out their spectral analysis. Based on the spectral harmonics analysis, the authors present a method for filtration of harmonics of DM and CM voltages aimed at limiting the capacitance parasitic currents: due to DM voltage – phase-to-phase parasitic current and CM voltage – ground parasitic currents. As the final result of the tests, almost complete elimination of leakage parasitic current form PE shock protection system was achieved.
W kolejowych pojazdach trakcyjnych trójfazowe falowniki MSI (Modulacja Szerokości Impulsów) wytwarzają pasożytnicze napięcia różnicowe (Differential Mode Voltage) i wspólne (Common Mode Voltage). Pasożytnicze napięcia są skutkiem ubocznym stosowania modulacji szerokościowej do kształtowania napięć międzyfazowych falownika. W artykule autorzy przedstawiają opis matematyczny napięć DM oraz CM i przeprowadzają ich analizę widmową. Na podstawie przeprowadzanej analizy autorzy przedstawiają metodę filtracji wybranych harmonicznych napięcia DM i CM dla ograniczania wytwarzanych przez nie prądów pasożytniczych: (DM) - międzyfazowych i (CM) – doziemnych. W wyniku badań osiągnięto prawie całkowitą eliminację pasożytniczego prądu upływu doziemnego z systemu ochrony przeciwporażeniowej PE.
Źródło:
Journal of Civil Engineering and Transport; 2019, 1, 1; 15-25
2658-1698
2658-2120
Pojawia się w:
Journal of Civil Engineering and Transport
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Decomposition of EMI Noise into Common and Differential Modes in PWM Inverter Drive System
Autorzy:
Kempski, A.
Smoleński, R.
Powiązania:
https://bibliotekanauki.pl/articles/262576.pdf
Data publikacji:
2006
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
electromagnetic compatibility
common mode
differential mode
PWM inverter drive system
Opis:
In this paper [20] an analytical approach to decomposition of total phase EMI noises through algebraic calculations and the Fourier transform has been presented. Separating conducted EMI noise into different, common and differential mode (CM and DM) HF current components is important for a proper spectral analysis and application of EMI mitigation techniques. The results of calculations have been compared to EMI currents measured on the motor side of the PWM drive system. The proposed approach can be useful in comparative analysis of the influence of inverter control algorithms on spectra of CM currents in a given drive system.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2006, 12, 1; 53-58
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A novel high-swing high-speed with 187 µW power consumption Common-Mode Feedback Block (CMFB) based on rail-to-rail technique
Autorzy:
Mahdavi, S.
Noruzpur, F.
Ghadimi, E.
Khanshan, T. M.
Powiązania:
https://bibliotekanauki.pl/articles/397734.pdf
Data publikacji:
2017
Wydawca:
Politechnika Łódzka. Wydział Mikroelektroniki i Informatyki
Tematy:
common-mode feedback
high-speed
low voltage
folded cascode
high swing
sprzężenie zwrotne dla sygnału wspólnego
niskie napięcie
kaskoda odwrócona
Opis:
This paper presents a new high-swing, high-speed and low power continuous-time Common-Mode Feedback Block (CMFB) based on rail-to-rail technique. The main purposes of the proposed idea are to achieve high-speed, low settling time error, large output swing, and low power as well. Moreover, applying the worst case simulation (initial condition 0 and 1.8 volts) on the proposed CMFB circuit, the output voltage can be settled in the desired level just after 1.18ns noticeably. The settling time error and the power consumption of the suggested common-mode feedback circuit are just 103|iV and 187µW with the power supply of 1.8 volts respectively. Meanwhile, DC gain and phase margin of the amplifier are 74dB and 67 degree correspondingly, and 0.5pF capacitor load is applied to the output nodes of the amplifier. It is noteworthy that, the proposed idea is a good candidate for low voltage applications too. Because it just needs 2 overdrive voltage (AV) to start its performance. Applying the proposed idea on the folded cascode amplifier it achieves SNDR of 68.68dB with the Effective Number of Bits (ENOB) 11.15 bits respectively. The proposed CMFB occupies an active area of 155.58µm2 (10.56µm*14.73µm). Finally, the proposed structure is simulated in whole process corner condition and different temperatures from -70°C to +70°C. Simulation results are performed using the HSPICE BSIM3 model of a 0.18µm CMOS technology.
Źródło:
International Journal of Microelectronics and Computer Science; 2017, 8, 2; 50-56
2080-8755
2353-9607
Pojawia się w:
International Journal of Microelectronics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improved virtual space vector modulation for neutral point voltage oscillation and common-mode voltage reduction in neutral point clamped three-level inverter
Autorzy:
Fang, Junlong
Wang, Guangya
Li, Ran
Liu, Siyuan
Wang, Shuyu
Powiązania:
https://bibliotekanauki.pl/articles/1841339.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
three-level inverter
vector conversion
virtual space vector modulation
falownik trójpoziomowy
konwersja wektorowa
modulacja wektora przestrzeni wirtualnej
Opis:
The neutral point clamped (NPC) three-level inverter is widely used in high-voltage and high-power applications. However, neutral point voltage oscillation (NPVO) and common-mode voltage (CMV) problems exist in the NPC three-level inverter. In this paper, an improved virtual space vector modulation (VSVM) is proposed based on the reconstruction of a virtual small vector and a virtual medium vector. Compared with the traditional VSVM, an improved VSVM can effectively reduce the CMV. On this basis, a vector conversion method is proposed to further reduce the NPVO in the whole range. Simulation results verify the effectiveness and superiority of the improved VSVM.
Źródło:
Archives of Electrical Engineering; 2021, 70, 1; 203-218
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ograniczanie odkształceń napięcia sieci górniczych wytwarzanych przez napięcie zaburzeń wspólnych falowników
Voltages distortions in mining power supply systems caused by inverters common mode voltage
Autorzy:
Szymański, J.
Powiązania:
https://bibliotekanauki.pl/articles/187102.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technik Innowacyjnych EMAG
Tematy:
układy sieciowe typu IT
napędy elektryczne
górnictwo
mining power sypply systems
electrical drives
mining
Opis:
Do zasilania napędów elektrycznych w górnictwie odkrywkowym stosuje się nieuziemione układy sieciowe typu IT. Wytworzone w falowniku napięcie zaburzeń doziemnych jest przyczyną odkształceń napięcia zasilania. Odkształcone fazowe napięcie zasilania przemiennika częstotliwości może spowodować jego uszkodzenie. Badania przeprowadzone przez autora wykazały, że zastosowanie dodatkowej sztucznej pojemności na zasilaniu przemiennika częstotliwości mocno ogranicza odkształcenia fazowych napięć zasilania.
Mining electrical drives are supplied from ungrounded IT power networks. Common mode voltage generated in an inverter is a major cause of power supply voltage deformation. Phase voltage distortions can be the reason of the inverter damage. The author's research shows that voltage distortions can be eliminated by additional artificial capacitances connected between a PE wire and power inputs of VFD.
Źródło:
Mechanizacja i Automatyzacja Górnictwa; 2012, R. 50, nr 8, 8; 5-10
0208-7448
Pojawia się w:
Mechanizacja i Automatyzacja Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Układ do pomiaru zespolonego tłumienia napięcia współbieżnego (CMRR) wzmacniaczy operacyjnych
A circuit for measuring the complex common mode rejection ratio (CMRR) of operational amplifiers
Autorzy:
Wiśniewski, J.
Powiązania:
https://bibliotekanauki.pl/articles/152332.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
miernictwo układów scalonych
układy scalone
wzmacniacze operacyjne
integrated circuits
measurements of integrated circuits
operational amplifiers
Opis:
W pracy rozważono zagadnienie precyzyjnego pomiaru, przy prądzie przemiennym i zamkniętej pętli sprzężenia zwrotnego, współczynnika tłumienia napięcia współbieżnego CMRR (z ang.: Common Mode Rejection Ratio) o dużej wartości rzędu 1∙104 ÷ 1∙108 (tj. (80 ÷ 160)dB) scalonych wzmacniaczy operacyjnych. W wyniku dokonanej analizy teoretycznej właściwości metrologicznych układu pomiarowego ustalono związek między mierzonym w układzie stosunkiem napięć zależnym od współczynnika CMRR a innymi parametrami badanego wzmacniacza, w tym zwłaszcza wzmocnieniem napięcia różnicowego, stanowiący podstawę ilościowej oceny błędu metody pomiarowej. Bazując na tych wynikach, zaproponowano całkowicie nowe techniczne rozwiązanie układu pomiarowego wyposażonego w specjalny transformator pomiarowy napięcia przemiennego z wtórnymi uzwojeniami o nawoju trifilarnym, co przyczyniło się do wyeliminowania wpływu skończonej wartości wzmocnienia różnicowego badanego wzmacniacza operacyjnego na mierzoną wartość współczynnika CMRR. Zastosowana metoda synchronicznej (fazoczułej, homodynowej) detekcji napięcia przemiennego pozwala na pomiar zarówno stałoprądowej wartości tego współczynnika (CMRR0), jak i trzydecybelowej częstotliwości załamania jego modułu (ƒ0,CMRR). Ponadto przyczynia się do wyeliminowania wpływu zarówno temperaturowych, jak i czasowych, dryftów stałoprądowych parametrów (napięcie offsetu, prądy polaryzacji, prąd offsetu) badanego wzmacniacza oraz jego własnych szumów (termicznych i strukturalnych), a także zakłóceń zewnętrznych na mierzoną wartość współczynnika CMRR.
This paper deals with the problem of a precise measurement of the common mode rejection ratio (CMRR) coefficient of high value from the range 1∙104 ÷ 1∙108 (i.e. 80dB to 160dB) of integrated operational amplifiers at alternating current and closed-loop feedback There was performed the theoretical analysis of metrological parameters of a measuring circuit. As a result there was established the relationship between the voltage ratio (measured in the system) dependent on the CMRR coefficient and the other parameters of the tested amplifier, in particular the differential voltage gain (Kr) (Eq. (13)). This relationship is the basis of quantitative evaluation of the measurement method error. Based on these results, a completely new technical solution of the measurement circuit equipped with a special measuring voltage transformer (Tr) with the secondary trifilar windings was proposed (Figs. 4 and 5). It caused elimination of the effect of the differential open-loop voltage gain (Kr) finite value of the tested operational amplifier on the measured value of the CMRR coefficient (Fig. 3). The applied method of synchronous (phase sensitive, homodyne) detection of the alternating output voltage Uwy (Figs. 4 and 5) allows measurement of both the direct current (DC) value of this coefficient (CMRR0) and the three-decibel break-down frequency (ƒ0,CMRR) of the absolute value CMRR. Moreover, it contributes to elimination of the influence of temperature and time dependent drift DC parameters (offset voltage, input bias currents, input offset current) of the tested amplifier as well as its own intrinsic noise (thermal and structural) and external disturbances on the measured value of CMRR. There were made measurements of randomly selected amplifiers of the same type LM741 but from different producers in the number of 100 units. As a result a large scattering value of this factor of up to 10000:1 (from 75dB to 155dB) was found. Three-decibel break-down frequency ƒ0,CMRR of the absolute value CMRR took the values from the range: 10Hz ÷ 3kHz. The measurement results confirmed the hypothesis posed by the author in the second section of the work that the CMRR coefficient has an indefinite sign. The advantage of the proposed by the author measurement circuit is its technical simplicity, easy reproducibility and low price. For these reasons, it may have wide practical application.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 1, 1; 9-15
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analytical models synthesis of power electronic converters
Autorzy:
Ales, A.
Cheurfi-Belhadj, M. A.
Schanen, J. L.
Moussaoui, D.
Roudet, J.
Powiązania:
https://bibliotekanauki.pl/articles/136182.pdf
Data publikacji:
2017
Wydawca:
EEEIC International Barbara Leonowicz Szabłowska
Tematy:
EMC modelling
differential mode
common mode
EMC filter
LISN
EMI
conducted noise
noise source
Opis:
In this paper we proposes a synthesis of different mathematical models of power electronic converters based on Thevenin/Norton equivalent circuits. Those models, composed by impedances and harmonic noise sources, are helpful to predict the conducted ElectroMagnetic Interferences (EMI) generated by converters connected to the electrical network. Moreover, the extracted impedances are determining for sizing EMC filters. The proposed analytical model is tested with PSpice simulations and validated by experimental measurements, from DC frequency until 30MHz.
Źródło:
Transactions on Environment and Electrical Engineering; 2017, 2, 1; 52-59
2450-5730
Pojawia się w:
Transactions on Environment and Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Technique to improve CMRR at high frequencies in CMOS OTA-C filters
Autorzy:
Blakiewicz, G.
Powiązania:
https://bibliotekanauki.pl/articles/200504.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
common-mode rejection ratio
CMRR
CMOS
OTA
differential pair
OTA-C filters
component mismatch
Opis:
In this paper a technique to improve the common-mode rejection ratio (CMRR) at high frequencies in the OTA-C filters is proposed. The technique is applicable to most OTA-C filters using CMOS operational transconductance amplifiers (OTA) based on differential pairs. The presented analysis shows that a significant broadening of CMRR bandwidth can be achieved by using a differential pair with the bodies of transistors connected to AC ground, instead of using a pair with the bodies connected to the sources. The key advantages of the technique are: no increase in power consumption (except for an optional tuning circuit), a small increase of a chip area, a slight modification of the original filter. The simulation results for exemplary OTAs and a low-pass filter, designed in a 0.35 μm CMOS process, show the possibility of broadening the CMRR bandwidth several times.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2013, 61, 3; 697-703
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Układ do pomiaru tłumienia napięcia współbieżnego precyzyjnych komparatorów napięcia typu LM111
Circuit for measuring of common mode rejection ratio of precise voltage comparators type LM111
Autorzy:
Wiśniewski, J.
Powiązania:
https://bibliotekanauki.pl/articles/158333.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
komparatory napięcia
miernictwo układów scalonych
układy scalone
integrated circuits
measurement of integrated circuits
voltage comparators
Opis:
W pracy rozważono zagadnienie pomiaru, przy prądzie przemiennym i zamkniętej pętli sprzężenia zwrotnego, współczynnika tłumienia napięcia współbieżnego (CMRR) o wartości rzędu 1•105 ÷ 1•107 (tj. (100 ÷ 140) dB) scalonych komparatorów napięcia typu LM111. W wyniku przeprowadzonej analizy teoretycznej właściwości metrologicznych układu pomiarowego ustalono istotny związek między stosunkiem mierzonych w układzie napięć, zależnym od współczynnika CMRR, a innymi parametrami badanego komparatora napięcia, w tym zwłaszcza wzmocnieniem napięcia różnicowego, stanowiący podstawę ilościowej oceny błędu metody pomiarowej. Zaproponowano nowe techniczne rozwiązanie układu pomiarowego zawierające specjalny transformator pomiarowy napięcia przemiennego wyposażony we wtórne uzwojenia o nawoju bifilarnym, co przyczyniło się do wyeliminowania wpływu skończonej wartości wzmocnienia różnicowego badanego komparatora napięcia na mierzoną wartość współczynnika CMRR.
The comparator open-loop common-mode rejection ratio (CMRR) is a measure of the comparator's ability to reject common signals present in equal measure at both inputs. CMRR according to the definition is the ratio of the differential-mode gain to common-mode gain. Often, manufacturer data sheets only give DC CMRR value and CMRR curve over frequency while no measurement methods are given. The present work deals with measurements of common mode rejection ratio of values of the order 1•105 ÷ 1•107 (i.e. (100 ÷ 140) dB) of the voltage comparators type LM111. The present investigation concerns the method of measurement of coefficient CMRR with closed loop feedback of voltage comparator at alternating current. Important relationship between measured output voltage (Uwy) and finite values of parameters of comparator and others parameters of measuring circuit has been discovered by means of detailed analysis (see equations (12) and (17)). This relationship is the basis for quantitative analysis of the error of measuring method. Finally proposed - by author - a new solution of measuring circuit different from others existing up to date offer significant improvements over previous methods and is capable of accurate measurements on high-performance analogue comparators. It is based on special precise inductive voltage transformer with bifilar windings (Tr, Fig. 4). Such the error of measuring method is independent from finite value of differential open loop voltage gain and the output voltage is directly related to CMRR. The unity gain differential amplifier (buffer) which is implemented at input device under test (DUT: KB, Fig. 2÷4) eliminates differential and common-mode input resistances of DUT on measuring output voltage and thereby CMRR.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 10, 10; 1238-1242
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Resonant DC link inverters for AC motor drive systems – critical evaluation
Autorzy:
Turzyński, Marek
Chrzan, P. J.
Powiązania:
https://bibliotekanauki.pl/articles/200688.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
soft-switching
resonant DC link inverter
quasiresonant DC link inverter
common-mode voltage
voltage gradient
zero voltage switching
przekształtnik quasirezonansowy DC
gradient napięcia
przekształtnik rezonansowy DC/DC
Opis:
In this survey paper, resonant and quasiresonant DC link inverters are reexamined for AC motor drive applications. Critical evaluation of representative topologies is based on simulation and waveform analysis to characterize current/voltage stress of components, control timing constraints and feasibility. A special concern over inverter common-mode voltage and voltage gradient du/dt limitation capacity is discussed for motor bearing and winding insulation safety. Experimental records of the laboratory developed parallel quasiresonant DC link inverter feeding induction motor confirm results of analysis. Comparative tables and simulation results demonstrate characteristic features of various schemes.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2019, 67, 2; 241-252
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Napięcia wałowe i prądy łożyskowe w silnikach prądu stałego dużej mocy – stosowanych w maszynach wyciągowych
Shaft voltages and bearing currents in high-power DC motors – applied on hoist machines
Autorzy:
Pocztowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/2056379.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
maszyny elektryczne prądu stałego
maszyny wyciągowe
przekształtniki tyrystorowe
napięcia wałowe
prądy łożyskowe
zaburzenia przewodzone
zaburzenia wspólne
DC electric machines
hoisting machines
thyristor converters
shaft voltages
bearing currents
conducted disturbance
common mode
Opis:
Artykuł opisuje przyczyny, skutki oraz propozycje minimalizacji skutków występowania napięć wałowych i prądów łożyskowych w dużych silnikach prądu stałego zasilanych z przekształtników tyrystorowych stosowanych w maszynach wyciągowych. W pierwszej części przedstawiono podstawowe przyczyny występowania napięć wałowych oraz prądów łożyskowych w silnikach prądu stałego zasilanych z przekształtników tyrystorowych stosowanych w maszynach wyciągowych. W dalszej części opisano sposoby pomiaru napięć wałowych oraz prądów łożyskowych wykorzystywanych przez autora artykułu, przedstawiono wady i zalety ww. metody. W artykule opisano przykład nieprawidłowego działania układu sterowania maszyny wyciągowej spowodowanej występowaniem napięć wałowych. Przedstawiono jedną z metod minimalizacji skutków występowania napięć wałowych i prądów łożyskowych w łożyskach głównych maszyn wyciągowych, zapewniającą zwiększenie bezpieczeństwa i niezawodność ww. układu. W artykule przedstawiono wyniki pomiarów układów napędowych wykorzystujących kilka typów silników prądu stałego.
This short document describes the causes, effects and proposals for minimizing the effects of shaft and bearing currents in large DC motors powered by thyristor converters used in hoisting machines. The article describes an incorrect operation of the winding machine control system caused by the occurrence of shaft voltages generated by the common mode (asymmetric). It presents one of the ways to minimize the effects of the occurrence of shaft voltages and bearing currents in the main bearings hoisting machines, providing increased safety and reliability of the system.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2018, 2, 118; 125-128
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A 1.67 pJ/Conversion-step 8-bit SAR-Flash ADC Architecture in 90-nm CMOS Technology
Autorzy:
Khatak, Anil
Kumar, Manoj
Dhull, Sanjeev
Powiązania:
https://bibliotekanauki.pl/articles/1844527.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
analog to digital converter
ADC
successive approximation register (SAR)
common mode current feedback gain boosting
CMFD-GB
residue amplifier
RA
spurious free dynamic range
SFDR
integral nonlinearity
INL
differential nonlinearity
DNL
Opis:
A novice advanced architecture of 8-bit analog to digital converter is introduced and analyzed in this paper. The structure of proposed ADC is based on the sub-ranging ADC architecture in which a 4-bit resolution flash-ADC is utilized. The proposed ADC architecture is designed by employing a comparator which is equipped with common mode current feedback and gain boosting technique (CMFD-GB) and a residue amplifier. The proposed 8 bits ADC structure can achieve the speed of 140 mega-samples per second. The proposed ADC architecture is designed at a resolution of 8 bits at 10 MHz sampling frequency. DNL and INL values of the proposed design are -0.94/1.22 and -1.19/1.19 respectively. The ADC design dissipates a power of 1.24 mW with the conversion speed of 0.98 ns. The magnitude of SFDR and SNR from the simulations at Nyquist input is 39.77 and 35.62 decibel respectively. Simulations are performed on a SPICE based tool in 90 nm CMOS technology. The comparison shows better performance for this proposed ADC design in comparison to other ADC architectures regarding speed, resolution and power consumption.
Źródło:
International Journal of Electronics and Telecommunications; 2021, 67, 3; 347-354
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Napięcia wałowe i prądy łożyskowe w silnikach prądu stałego dużej mocy stosowanych w maszynach wyciągowych
Shaft voltages and bearing currents in high-power DC motors – applied on hoist machines
Autorzy:
Pocztowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/304736.pdf
Data publikacji:
2018
Wydawca:
Wydawnictwo Druk-Art
Tematy:
maszyny elektryczne prądu stałego
maszyny wyciągowe
przekształtniki tyrystorowe
napięcia wałowe
prądy łożyskowe
zaburzenia przewodzone
zaburzenia wspólne
DC electric machines
hoisting machines
thyristor converters
shaft voltages
bearing currents
conducted disturbance
common mode
Opis:
Artykuł opisuje przyczyny, skutki oraz propozycje minimalizacji skutków występowania napięć wałowych i prądów łożyskowych w dużych silnikach prądu stałego zasilanych z przekształtników tyrystorowych, stosowanych w maszynach wyciągowych.W pierwszej części przedstawiono podstawowe przyczyny występowania napięć wałowych oraz prądów łożyskowych w silnikach prądu stałego zasilanych z przekształtników tyrystorowych, stosowanych w maszynach wyciągowych. W dalszej części opisano sposoby pomiaru napięć wałowych oraz prądów łożyskowych wykorzystywanych przez autora artykułu, przedstawiono wady i zalety ww. metody. W artykule opisano przykład nieprawidłowego działania układu sterowania maszyny wyciągowej, spowodowanego występowaniem napięć wałowych. Przedstawiono jedną z metod minimalizacji skutków występowania napięć wałowych i prądów łożyskowych w łożyskach głównych maszyn wyciągowych, zapewniającą zwiększenie bezpieczeństwa i niezawodność ww. układu. W artykule przedstawiono wyniki pomiarów układów napędowych wykorzystujących kilka typów silników prądu stałego.
This short document describes the causes, effects and proposals for minimizing the effects of shaft and bearing currents in large DC motors powered by thyristor converters used in hoisting machines. The article describes an incorrect operation of the winding machine control system caused by the occurrence of shaft voltages generated by the common mode (asymmetric). It presents one of the ways to minimize the effects of the occurrence of shaft voltages and bearing currents in the main bearings hoisting machines, providing increased safety and reliability of the system.
Źródło:
Napędy i Sterowanie; 2018, 20, 12; 96-99
1507-7764
Pojawia się w:
Napędy i Sterowanie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Review and comparison of methods for limiting leakage currents in single-phase transformerless PV inverter topologies
Autorzy:
Kołodziejski, Wojciech
Jasielski, Jacek
Kuta, Stanisław W.
Szerszeń, Grzegorz
Machowski, Witold
Powiązania:
https://bibliotekanauki.pl/articles/29521110.pdf
Data publikacji:
2022
Wydawca:
Akademia Tarnowska
Tematy:
Differential Mode (DM) voltage
Common Mode (CM) voltage
grid-tied inverter
leakage current
parasitic capacity
photovoltaic (PV) systems
transformerless inverter
napięcie trybu różnicowego (DM).
napięcie trybu wspólnego (CM).
falownik podłączony do sieci
prąd upływowy
pojemność pasożytnicza
systemy fotowoltaiczne (PV).
falownik beztransformatorowy
Opis:
Transformerless inverters are widely used in different photovoltaic nonisolated ac module applications, mainly in grid-tied photovoltaic (PV) generation systems, due to the benefits of achieving high efficiency over a wide load range, and low cost. Various transformerless inverter topologies have been proposed to meet the safety requirement of low ground leakage currents, such as specified in the VDE-4105 standard and low-output ac-current distortion. Topology modifications of transformerless full bridge inverters are designed to balance and maintain a constant common mode output voltage, thereby eliminating or reducing leakage currents. This article reviews and compares the different methods for limiting leakage currents in known topologies of the full-bridge transformerless inverters, such as: H4, H5, H6, HERIC, and their improvements. The main topologies and strategies used to reduce the leakage current in transformerless schemes are summarized, highlighting advantages and disadvantages and establishing points of comparison with similar topologies. To compare the properties of different medium to high power inverters, PV inverter topologies were implemented using IGBTs and tested with the same components, same simulation parameters in PSPICE to evaluate their performance in terms of energy efficiency and leakage current characteristics. The detailed power stage operating principles, extended PWM modulator, and integrated universal gate driver with galvanic isolation in the transmission path of control signal for all IGBTs of the inverter, as well isolated and floating bias power supply for gate drivers are described.
Źródło:
Science, Technology and Innovation; 2022, 16, 3-4; 1-19
2544-9125
Pojawia się w:
Science, Technology and Innovation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
CIM in Smart Grid implementation – usage scenarios
Wspólny mode informacyjny CIM w realizacji sieci intelignetnych - scenariusze zastosowań
Autorzy:
Czerwonka, P.
Powiązania:
https://bibliotekanauki.pl/articles/397653.pdf
Data publikacji:
2012
Wydawca:
ENERGA
Tematy:
smart grid
CIM
sieci inteligentne
common information model
Opis:
The paper consists of three parts: general presentation of Common Information Model (CIM), it’s application in solving selected power system problems and conclusions. CIM is an independent data model platform described in IEC 61970/61968 recommended for Smart Grid architectures. In current version it contains about 900 classes and 2650 native attributes, describing diff erent aspects of energy domain. In general, CIM provides basis for modeling topologies of the power grid for transmission and power grid, exchange of messages among diff erent stakeholders and standardized interface specifi cation between diff erent systems. Changing power infrastructure needs a  new approach to  Information and Communication Technologies. A lot of new services, utilities and use cases arrive and stakeholders within Smart Grid have to deal with interoperability and integration issues. Amount and kind of data exchanged between diff erent systems will rise in result of increasing number of systems in Smart Grid. There is a need for international standardized semantic data model for data exchange between systems from diff erent vendors. Such elegant solution would reduce cost of Smart Grid interoperability connected with integration eff orts. The use of CIM can be the answer for this need. As a potential international standard it has wide acceptance of energy sector and is mentioned in many national standardization roadmaps for Smart Grid. It can be used to describe and exchange data about power grid topology, which is very important in building common map of energy infrastructure provided by many small and medium power vendors and power islands. The necessity of measurement data exchange, energy scheduling and reservation as a source for decision making and forecasting system is also a factor that can be described and solved by CIM usage.
Artykuł ten składa się z trzech części: z ogólnej prezentacji wspólnego modelu informacyjnego (CIM, Common Information Model), jego zastosowania w rozwiązywaniu wybranych problemów systemu elektroenergetycznego i z wniosków. CIM jest niezależną platformą modelu danych opisaną w normach PN-EN (IEC) 61970/61968 i zalecaną dla architektury sieci inteligentnych (Smart Grid). W obecnej wersji zawiera ok. 900 klas i 2650 rodzimych atrybutów opisujących różne aspekty dziedziny energetyki. CIM stanowi podstawę do modelowania topologii elektroenergetycznej sieci przesyłowej oraz systemu elektroenergetycznego, wymiany wiadomości między różnymi zainteresowanymi stronami oraz znormalizowanej specyfikacji interfejsu pomiędzy różnymi systemami.
Źródło:
Acta Energetica; 2012, 2; 4-12
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-20 z 20

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies