Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Water Distribution Systems" wg kryterium: Wszystkie pola


Tytuł:
A Model of time Variability of Characteristic Parameters of the Water Distribution System as a Base of Information and the Basis of Mathematical Modelling
Autorzy:
Trębicka, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/123351.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
computer simulation
distribution systems
water supply network
mathematical model
dynamic model
computer modelling
Opis:
The subject of the paper is the Bialystok water supply network. The studies on the Bialystok water supply network are aimed at identifying new, more rational ways of operation (decreasing the pressure value) and defining the conditions for expansion and modernization of the water supply network, with the particular system analysis as a part of identifying the most dangerous places on the network. The increase of requirements concerning the quality and the time of realisation in the scope of the design studies requires the introduction of computer technology in calculations. The work presents the processes based on mapping and refinement of specific conservative states of the water distribution system (SDW), using mathematical modelling taking into account the latest available computer techniques.
Źródło:
Journal of Ecological Engineering; 2020, 21, 1; 46-51
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Model-Based Approach to Risk Evaluation and the Assessment of Protection Provided by Water Intake and Treatment Systems
Autorzy:
Wysowska, Ewa
Kicińska, Alicja
Powiązania:
https://bibliotekanauki.pl/articles/2173238.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
health risk
metals
organic compound
microbiological pathogen
water distribution system
Opis:
This study presents an assessment of the protection provided by water intake and treatment systems against potential health risk to water consumers. To perform the assessment a case study was conducted involving modelling and risk assessment based on scenarios of decreasing water quality at the intakes (i.e. emergency situations). The study sites were two continuously operating water treatment plants in Southern Poland (CEE). The study material were the results of tests conducted in the years 2012–2019 on samples of water taken directly at the intakes and samples of treated water. The samples were used to determine the concentration of selected metals (Cd, Cr, Mn, Ni, Pb and Zn), organic pollutants (benzo(a)pyrene, benzene, acrylamide, epichlorohydrin, vinyl chloride and 1,2-dichloroethane) and bacteriological pollutants (Coliform bacteria, Escherichia coli, Enterococcus faecali and Clostridium perfringens). The non-carcinogenic (HI) and carcinogenic (CR) hazard indexes were estimated based on the quality of water at the intake using linear regression models. The risk values obtained were compared with permissible values specified in the US EPA methodology. It was demonstrated that the concentrations of the xenobiotics analysed in treated water would have to increase 11 times in the case of adults and 29 times in the case of children before the risk level related to drinking water exceeded permissible values. In the least favourable exposure scenario modelled, assuming the presence of organic xenobiotics in potable water, the total HI amounts to only 10% of the permissible value in adults and 1.5% in children. The total CR calculated for the 3-times lower water quality did not exceed permissible values, which proves that the water treatment systems are safe.
Źródło:
Journal of Ecological Engineering; 2022, 23, 7; 284--298
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Algorytmy hybrydowe optymalizacji w zastosowaniu do problemu sterowania systemami dystrybucji wody
Hybrid optimization algorithm for control of water distribution systems
Autorzy:
Trawicki, D.
Urbowska, W.
Powiązania:
https://bibliotekanauki.pl/articles/153958.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
systemy dystrybucji wody
zintegrowane sterowanie ilością i jakością
sterowanie optymalne
hierarchiczna struktura sterowania
sterowanie predykcyjne
algorytmy genetyczne
programowanie całkowitoliczbowe
water distribution systems
integrated water quantity and quality
optimal control
hierarchical control structure
genetic algorithms
mixed-integer programming
Opis:
W pracy analizowany jest problem optymalizującego zintegrowanego sterowania ilością i jakością w systemach dystrybucji wody. Proponowane decyzje i sterowania powinny zapewniać optymalizację przyjętego wskaźnika jakości, przy spełnieniu ograniczeń właściwych tej klasie systemów. Ostatecznie do rozwiązania złożonych zadań optymalizacji dynamicznej zaproponowane zostało podejście hybrydowe, wspomagające predykcyjne algorytmy sterowania i wykorzystujące zalety analizowanych w pracy algorytmów: algorytmu bazującego na metodzie podziałów i ograniczeń oraz algorytmów genetycznych.
In this paper an approach to optimizing integrated control of quantity and quality in water distribution systems is presented. The optimizing integrated control meets consumer demand for drinking-quality water and maintains constraints while minimizing the operating costs. In predictive control 24 hours demand prediction and mathematical model of the water distribution system is used. The structure of basic control consists of two layers. To optimizing control at the upper layer hybrid algorithm is used. This algorithm is a combination of branch and bound algorithm and genetic algorithm, presented as well in this paper.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 4, 4; 17-20
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Alokacja urządzeń pomiarowych hydrauliki w systemach wodociągowych w warunkach niepewności
The hydraulic sensor placement under uncertainty conditions in drinking water distribution systems
Autorzy:
Cimiński, A.
Duzinkiewicz, K.
Głowacki, J.
Powiązania:
https://bibliotekanauki.pl/articles/156493.pdf
Data publikacji:
2008
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
alokacja pomiarów
niepewność
systemy wodne
estymacja
sensor allocation
estimation
uncertainty
drinking water distribution systems
Opis:
W artykule zaproponowana została metoda wspomagania decyzji alokacji urządzeń pomiarowych hydrauliki w systemie wodociągowym (SW) rozważana w powiązaniu z zagadnieniem estymacji wielkości niezmierzonych SW oraz w warunkach korzystania z niedokładnych danych pomiarowych. Problem alokacji został sformułowany jako zagadnienie wielokryterialne, w którym składowymi wektora kryteriów są elementy rachunku kosztów tworzenia nowych punktów pomiaru oraz elementy oceny jakości estymat niemierzonych wielkości. Efektywność proponowanej metody została przetestowana symulacyjnie z wykorzystaniem danych sieci wodociągowej miasta Chojnice.
The decision supporting method for hydraulic sensor placement in Drinking Water Distribution System (DWDS) considered together with unmeasured variable estimation problem and under uncertainty conditions is proposed in the paper. The sensor allocation problem was formulated as a multiobjective optimisation problem. The two types of objective functions were considered during solving this problem: quality of estimates of unmeasured variables and cost connected with a new measurement point construction. A new hybrid method which integrates a multiobjective genetic algorithm and a set bounded estimation method to solve the sensor allocation problem is proposed. The proposed method was applied to a real water network (Chojnice DWDS) and its performance was validated by simulations.
Źródło:
Pomiary Automatyka Kontrola; 2008, R. 54, nr 11, 11; 786-790
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An interval estimator for chlorine monitoring in drinking water distribution systems under uncertain system dynamics, inputs and chlorine concentration measurement errors
Autorzy:
Łangowski, R.
Brdys, M. A.
Powiązania:
https://bibliotekanauki.pl/articles/330246.pdf
Data publikacji:
2017
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
observer
bounding method
modelling dynamics
water quality
obserwator
dynamika modelowania
jakość wody
Opis:
The design of an interval observer for estimation of unmeasured state variables with application to drinking water distribution systems is described. In particular, the design process of such an observer is considered for estimation of the water quality described by the concentration of free chlorine. The interval observer is derived to produce the robust interval bounds on the estimated water quality state variables. The stability and robustness of the interval observer are investigated under uncertainty in system dynamics, inputs, initial conditions and measurement errors. The bounds on the estimated variables are generated by solving two systems of first-order ordinary differential equations. For that reason, despite a large scale of the systems, the numerical efficiency is sufficient for the on-line monitoring of the water quality. Finally, in order to validate the performance of the observer, it is applied to the model of a real water distribution network.
Źródło:
International Journal of Applied Mathematics and Computer Science; 2017, 27, 2; 309-322
1641-876X
2083-8492
Pojawia się w:
International Journal of Applied Mathematics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of Multilayer Perceptron for the Calculation of Pressure Losses in Water Supply Lines
Zastosowanie perceptronu wielowarstwowego do obliczeń strat ciśnienia w przewodach wodociągowych
Autorzy:
Czapczuk, A.
Dawidowicz, J.
Piekarski, J.
Powiązania:
https://bibliotekanauki.pl/articles/1813822.pdf
Data publikacji:
2017
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
water distribution systems
artificial intelligence
expert systems
artificial neuronal networks
heuristic methods
calculation of pressure losses
systemy dystrybucji wody
sztuczna inteligencja
systemy ekspertowe
sztuczne sieci neuronowe
metody heurystyczne
obliczenia strat ciśnienia
Opis:
Numerical methods have been widely used for many years in the design and operation of water supply systems. Specialised computer programmes offer more and more facilities, especially for data entry and viewing, but they still function on the basis of predetermined algorithms. At present, however, we strive to create computational programmes with a certain degree of creativity, which should make it easier for users to make decisions at various stages of the task and improve the quality of their solutions. The increasing power of computers will not solve complex problems alone. Only by introducing appropriate calculation methods can we obtain the right results. It seems that classical algorithms with a formalised course can be supplemented, nowadays, with far more advanced computational techniques. This paper presents an literature review on the use of artificial neural networks in the design and operation of water distribution systems. Presented in the second part of the paper, is an overview of the artificial neural network, developed for the calculation of pressure losses in water supply lines. The calculation of hydraulic piping with the EPANET programme for various input parameters resulted in a collection of 16,260 training examples. Input parameters of the neural network include pipe length, measurable flow, absolute roughness coefficient and the nominal diameter. Very high compatibility was obtained between the calculation results for those pressure losses obtained from the EPANET programme and those obtained from the multi-layered perceptron with one hidden layer.
Metody numeryczne stosuje się powszechnie od wielu lat w projektowaniu i eksploatacji systemów zaopatrzenia w wodę. Specjalistyczne programy komputerowe oferują coraz więcej udogodnień, szczególnie w zakresie wprowadzania danych oraz przeglądania wyników, lecz nadal funkcjonują na podstawie z góry określonych algorytmów. Obecnie dąży się jednak do stworzenia programów obliczeniowych, które będzie charakteryzować pewien stopień kreatywności, co powinno ułatwić użytkownikom podejmowanie decyzji na różnych etapach realizacji zadania i poprawić jakość rozwiązań. Zwiększająca się moc obliczeniowa komputerów samoistnie nie rozwiąże złożonych problemów. Dopiero wprowadzanie odpowiednich metod obliczeniowych, pozwala uzyskać właściwe efekty. Wydaje się, że klasyczne algorytmy o sformalizowanym przebiegu, można obecnie uzupełnić znacznie bardziej zaawansowanymi technikami obliczeniowymi. W niniejszej pracy dokonano przeglądu literatury w zakresie zastosowania sztucznych sieci neuronowych w projektowaniu systemów dystrybucji wody. W drugiej części artykułu zamieszczono omówienie sztucznej sieci neuronowej do obliczeń strat ciśnienia w przewodach wodociągowych. W wyniku obliczeń hydraulicznych przewodów wodociągowych za pomocą programu EPANET dla różnych wartości parametrów wejściowych uzyskano zbiór 16260 przykładów uczących. Parametry wejściowe sieci neuronowej to długość przewodu, przepływ miarodajny, współczynnik chropowatości bezwzględnej oraz średnica nominalna. Uzyskano bardzo wysoką zgodność pomiędzy wynikami obliczeń strat ciśnienia z programu EPANET i perceptronu wielowarstwowego z jedną warstwą ukrytą.
Źródło:
Rocznik Ochrona Środowiska; 2017, Tom 19; 200-210
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessing the Diameters of Water Pipes Using the k-Nearest Neighbours Method in the Calculations of Water Distribution Systems
Metoda oceny średnic przewodów wodociągowych za pomocą metody k-Najbliższych Sąsiadów w obliczeniach systemów dystrybucji wody
Autorzy:
Dawidowicz, J.
Kruszyński, W.
Andraka, D.
Czapczuk, A.
Powiązania:
https://bibliotekanauki.pl/articles/1813700.pdf
Data publikacji:
2018
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
water distribution system
hydraulic calculations
k-Nearest Neighbours Method
diameters of water pipes
system dystrybucji wody
obliczenia hydrauliczne
metoda k-Najbliższych Sąsiadów
średnice rurociągów
Opis:
Water distribution systems provide water in cities and in rural areas. The basic element through which water reaches the consumer are the water pipes, hence their correct design is extremely important. The choice of pipe diameter requires hydraulic calculations. Computer programmes may choose diameters, but usually, it is the designer's task. This paper proposes a classifier, based on the k-Nearest Neighbours method, which, on the basis of a reliable flow, will assess the appropriateness of the diameter chosen. In the work 11961 training examples were obtained containing the input variable in the form of a nominal flow, through water supply line Qm, corresponding to the output variable DN. On the basis of the set of training examples, a model was constructed and the diameters of the water pipes were classified using the k-Nearest Neighbours method, using various neighbourhood values. The k-NN method obtained, shows a high accuracy index in the classification of the diameters of the pipes in the k = 5 neighbourhood.
Systemy dystrybucji wody dostarczają wodę w miastach i na terenach wiejskich. Podstawowym elementem, przez który woda dociera do odbiorców są przewody wodociągowe, stąd niezwykle istotne jest ich poprawne zaprojektowanie. Dobór średnic rurociągów wymaga przeprowadzenia obliczeń hydraulicznych. Programy komputerowe mogą automatycznie dobierać średnice, ale najczęściej zadanie to należy do projektanta. Obecnie opracowuje się metody, które wspomagałyby projektantów w realizacji powyższych zadań. W niniejszej pracy zaproponowano klasyfikator oparty na metodzie k-Najbliższych Sąsiadów (k-NN), który na podstawie przepływu miarodajnego Qm będzie oceniał poprawność dobranej średnicy. W tym celu sporządzono 11961 przykładów uczących zawierających zmienną wejściową w postaci przepływu miarodajnego Qm oraz odpowiadającą mu zmienną wyjściową zdefiniowaną jako średnica nominalna DN. Na podstawie zestawu przykładów uczących skonstruowano klasyfikator za pomocą metody k-Najbliższych Sąsiadów, stosując różne wartości sąsiedztwa. Uzyskana metoda k-NN pokazuje wskaźnik wysokiej dokładności w klasyfikacji średnic rur dla wartości sąsiedztwa k = 5.
Źródło:
Rocznik Ochrona Środowiska; 2018, Tom 20, cz. 1; 528-537
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania stabilności biologicznej wody w wybranych systemach wodociągowych
Biological stability of drinking water in selected water distribution systems
Autorzy:
Sokołowska, A.
Jankowska, K.
Kulbat, E.
Olańczuk-Neyman, K.
Powiązania:
https://bibliotekanauki.pl/articles/237884.pdf
Data publikacji:
2015
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
woda powierzchniowa
woda podziemna
woda wodociągowa
ogólna liczba bakterii
surface water
groundwater
tap water
total bacteria number
Opis:
W pracy przedstawiono wyniki badań bakteriologicznych wody powierzchniowej i wód podziemnych (ujmowanych, oczyszczonych i rozprowadzanych siecią wodociągowa w rejonie Trójmiasta), które zasilają system dystrybucji charakteryzujący się małą wartością stosunku powierzchni kontaktu do objętości przesyłanej wody (≈0,65), a także wyniki laboratoryjnych badań ich stabilności biologicznej. Dokonano również oceny skuteczności stosowanych procesów technologicznych w zmniejszaniu ogólnej liczby bakterii, a w badaniach laboratoryjnych określono podatność wody wprowadzanej do systemu dystrybucji na ich wtórny wzrost. Stwierdzono, że w konwencjonalnym systemie oczyszczania wody powierzchniowej miała miejsce wysoka (95%) eliminacja ogólnej liczby bakterii, a proste systemy oczyszczania wód podziemnych były mało skuteczne w ich eliminacji. Wykazano, że możliwy jest wzrost ogólnej liczby bakterii w wodzie (nawet o 20%) na skutek wypłukiwania bakterii z filtrów. W systemach wodociągowych zasilanych zarówno wodą powierzchniową, jak i wodami podziemnymi stwierdzono wzrost wartości ogólnej liczby bakterii, przy czym był on większy w przypadku sieci zasilanej wodą powierzchniową (na odcinku 6 km – 330%) niż w niedezynfekowanej wodzie podziemnej (na 8 km odcinku – 170%). W badaniach laboratoryjnych potwierdzono korzystny wpływ procesów oczyszczania wody na zmniejszenie jej podatności na wtórny wzrost bakterii. W oczyszczonej wodzie podziemnej inkubowanej przez 7 d w temperaturze 5÷10oC szybkość wzrostu ogólnej liczby bakterii była o 80% mniejsza niż w ujmowanej wodzie.
Results of microbiological analysis and biological stability of surface and groundwater (taken, treated and distributed in the Tri-city region) which supply a distribution system with low contact surface to transferred water volume ratio (≈0.65) were presented. Additionally, the effectiveness of technological processes in reduction of the total number of bacteria (TNB) was evaluated and laboratory tests determined the susceptibility of water introduced into the system to the bacterial regrowth. It was established that high elimination (95%) of TNB occurred in the conventional surface water treatment system, while simple groundwater treatment systems were not effective in eliminating these bacteria. TNB was demonstrated to increase (even up to 20%) as a result of periodic leaching of bacteria from filters. In both surface and groundwater supply systems an increase in the TNB was observed. It was higher along the surface water network (330% for a 6-km section) than the non-disinfected groundwater network (170% for a 8-km section). The laboratory studies confirmed the beneficial effect of treatment processes on reduction of water susceptibility to bacterial regrowth. Increase in the total number of bacteria in the treated groundwater after 7-day incubation at temperatures ranging from 5 to 10oC was approximately 80% lower than in the raw water.
Źródło:
Ochrona Środowiska; 2015, 37, 4; 31-37
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania zmienności strat wody w wybranych systemach wodociągowych w latach 1990-2008
Variations in water loss observed in some water distribution systems over the period of 1990-2008
Autorzy:
Hotloś, H.
Powiązania:
https://bibliotekanauki.pl/articles/237321.pdf
Data publikacji:
2010
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
system dystrybucji wody
straty wody
sieć wodociągowa
pobór wody
obciążenie sieci
water distribution system
water losses
water-pipe network
water consumption
load factor
Opis:
Przedstawiono wyniki badań i analizy wartości wskaźników strat wody w dziesięciu miastach w Polsce w latach 1990-2008. Uwzględniono straty wody i jej zużycie na potrzeby technologiczne ujęcia i zakładu oczyszczania wody, całkowite straty wody w sieci wodociągowej, tj. straty wody w sieci wraz ze zużyciem wody na potrzeby własne systemu wodociągowo-kanalizacyjnego oraz straty wody w sieci wodociągowej. Najwięcej uwagi poświęcono stratom wody w sieci, które powstają wskutek wycieków przez nieszczelności w sieci wodociągowej oraz w czasie awarii rurociągów i armatury. W pracy dokonano oceny wpływu czynnika rzadko dotychczas branego pod uwagę w analizie zmian wielkości wycieków, a mianowicie zmniejszającego się w sposób znaczący od początku transformacji gospodarczej w Polsce obciążenia sieci wodociągowej. W latach 1990-2008 w konsekwencji zmniejszenia się (o 50÷70%) jednostkowego natężenia przepływu wody w sieci, wskutek spadku (o 36÷68%) całkowitego poboru wody zmniejszyły się (o 26(55)÷78%) w sposób naturalny straty wody w sieci, wyrażone stratami jednostkowymi. Wykazano, że miało to miejsce we wszystkich analizowanych systemach wodociągowych. Nie oznaczało to jednak, że w każdym z systemów zostały usunięte w jakimś stopniu przyczyny powstawania strat wody. Można o tym wnioskować dopiero na podstawie analizy zmian strat procentowych, która wykazała, że tylko w czterech systemach straty zmniejszyły się, w jednym znacząco wzrosły, a w czterech były prawie stałe w całym czasie obserwacji.
Water distribution systems of ten municipalities in Poland were chosen for the analysis of water loss parameters in the time span of 1990 to 2008. Consideration was focused on the following factors: water loss and water consumption for covering the technological needs of water intake and water treatment plant; water loss in the water-pipe network, and total water loss in the water-pipe net-work, which includes water loss in the network and water consumption for serving the needs of the water-supply and sewerage system. Emphasis was placed on leakage-related water losses, as well as on those observed during failures in the pipelines or plumbings. In this paper special attention is also given to the impact of the load factor, an issue that has seldom been taken into account in the analysis of change in the volume of leachates since 1990 (the year when Poland moved toward a free market economy). Over the period being analyzed, the volume of water loss in the pipelines (expressed in terms of unit loss) decreased by 26(55) to 78% as a natural consequence of the decrease of unit flow rate in the pipelines (by 50 to 70%) and the decrease in total water withdrawal (by 36 to 68%). This pattern was observed in all of the investigated water distribution systems, which does not mean, however, that the underlying causes of water loss in any of them have been rooted out so far. The analysis of the trends of change in water loss (%) has produced the following findings: reduction in water loss was observed only in four of the water distribution systems; one system displayed a decrease in water loss, and in four systems water loss was subject to slight variations.
Źródło:
Ochrona Środowiska; 2010, 32, 4; 21-25
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie wpływu ciśnienia na rozdział wody dla wybranych elementów wylotowych instalacji tryskaczowych.
Testing the Influence of Water Distribution Pressure for Some Outlet Elements Of Sprinkler Systems
Autorzy:
Domżał, A.
Wnęk, W.
Kubica, P.
Boroń, S.
Graba, M.
Powiązania:
https://bibliotekanauki.pl/articles/136803.pdf
Data publikacji:
2014
Wydawca:
Szkoła Główna Służby Pożarniczej
Tematy:
SUG-wodne
tryskacze
rozdział wody
FES-water sprinklers
water distribution
sprinklers
Opis:
W artykule przedstawiono wyniki badań laboratoryjnych dotyczących rozdziału wody poniżej i powyżej deflektora dla wybranych elementów wylotowych instalacji tryskaczowych, tzw. tryskaczy. Badaniom poddano cztery wybrane rodzaje tryskaczy rozpylających. Celem badań było ustalenie, w jaki sposób dla wybranych tryskaczy ciśnienie zmieniające się w zakresie 0,5 – 5,0 bar wpływa na rozdział wody poniżej i powyżej deflektora, a co za tym idzie, jak wiedza o rozdziale wody może wpływać na dobór tryskaczy do konkretnych zastosowań.
The article presents the results of laboratory studies on the distribution of water below and above the deflector for selected elements of the exhaust fixed sprinkler systems - so called sprinklers. The study involved four selected types of spray - fixed outflow of K = 57, K = 80, K = 150. The aim of the study was to determine how, for selected sprinkler pressure variable in the range of 0.5 - 5.0 bar affects the distribution of water below and above the deflector, and, therefore, the knowledge of the distribution of water may affect the selection of a specific application of sprinklers.
Źródło:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej; 2014, 4, 52; 108-115
0239-5223
Pojawia się w:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biological stability of water in water distribution systems. The effect of water treatment trials
Autorzy:
Wolska, M.
Powiązania:
https://bibliotekanauki.pl/articles/206902.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
water treatment
carbon
groundwater
microorganisms
nitrogen removal
organic carbon
surface waters
water aeration
water distribution systems
water supply systems
biological stability
inorganic nitrogen
uzdatnianie wody
węgiel
wody gruntowe
mikroorganizmy
usuwanie azotu
węgiel organiczny
wody powierzchniowe
napowietrzanie wody
systemy dystrybucji wody
wodociągi
stabilność biologiczna
stężenie dwutlenku węgla
azot nieorganiczny
Opis:
Research into the removal efficiency of biogenic substances, necessary for the growth of heterotrophic microorganisms, was carried out for the following water treatment trials: surface water, infiltrative water and mixed surface water after microsieving with aerated underground water. The results have shown that the efficiency of removal of organic substances, independently of the type of treated water, increased along with the organic carbon concentrations in raw water. The average effectiveness of phosphate removal was: 92.1%, 88.8% and 83.7% for surface, infiltrative and mixed water, respectively. In all analyzed systems, presence of phosphates was an limiting factor for the regrowth of microorganisms in the distribution system. In none of the water treatment trials, effective removal of inorganic nitrogen has been recorded.
Źródło:
Environment Protection Engineering; 2015, 41, 2; 147-157
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of various control techniques for motor-pump sets applied in selected water distribution systems
Autorzy:
Popenda, A.
Powiązania:
https://bibliotekanauki.pl/articles/1372738.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
elektrociepłownia
system dystrybucji wody
pompa
thermal-electric power station
water distribution system
pump
Opis:
The water distribution system applied in the thermal-electric power station EC Tychy SA is analyzed. The economical aspects of various control techniques for motor-pump sets in the aforementioned system are presented in the paper on the example of pumps working out of the cold season. The reasons of control losses occurring in the present system are depicted. The way of improvement of control effectiveness is proposed but unprofitability of the investment is also shown. A control of pumps by throttling and control by rotational speed changes are compared in the paper. It is shown that control by rotational speed changes causes similar losses like control by throttling if application of variable-speed technique is not preceded by appropriate adaptation of water distribution system, especially by adjustment of pump rated parameters.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2011, 4, 92; 97-101
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Controlling the distribution of cold water in air cooling systems of underground mines
Regulacja i sterowanie parametrami wody lodowej w instalacjach klimatyzacyjnych kopalń podziemnych
Autorzy:
Szlązak, N.
Obracaj, D.
Swolkień, J.
Piergies, K.
Powiązania:
https://bibliotekanauki.pl/articles/219050.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
klimatyzacja kopalń podziemnych
regulacja
sterowanie
woda lodowa
chłodnice powietrza
underground mines
air cooling systems
water reticulation system
automatic control
Opis:
In Polish underground mines in which excavations are subjected to high heat load, central and group cooling systems based on indirect cooling units are implemented. Chilled water, referred to as cold water and produced in chillers, is distributed through a pipeline network to air coolers located in mining and development districts. The coolers are often moved to other locations and the pipeline network undergoes constant modification. In such a system, parameters of cold water in different branches of the pipeline network need to be controlled. The article presents the principles for controlling the cooling capacity of air coolers installed in an underground mine. Also, the authors propose automatic control of water flow rate in underground pipeline network and in particular coolers, depending on the temporary cooling load in the system. The principles of such a system, controlling cold water distribution, and the functions of its individual components are described. Finally, an example of an automatic control of water flow rate in a central cooling system currently implemented in a mine is presented.
W polskich kopalniach podziemnych o dużym obciążeniu cieplnym wyrobisk stosuje się systemy klimatyzacji grupowej i centralnej, projektowane w oparciu o urządzenia chłodnicze pośredniego działania. Wytwarzana w agregatach chłodniczych woda lodowa rozprowadzana jest siecią rurociągów do chłodnic powietrza w rejonach eksploatacyjnych i przygotowawczych. Chłodnice są często przebudowywane, a sieć rurociągów ulega ciągłej zmianie. Obieg wody w sieci rurociągów wymaga ciągłej regulacji w za kresie wymaganego natężenia przepływu wody lodowej w poszczególnych odgałęzieniach sieci rurociągów. W artykule przedstawiono zasady regulacji wydajności chłodnic powietrza. Zaproponowano układ automatycznego sterowania rozpływem wody lodowej w sieci, jaką tworzą rurociągi i chłodnice powietrza, w zależności od chwilowego zapotrzebowania mocy w chłodnicach. Omówiono zasady takiej regulacji oraz funkcje, jakie muszą spełniać poszczególne elementy układu sterowania rozpływem wody lodowej. Przedstawiono przykład wdrażanego aktualnie sterowania rozpływem wody lodowej w klimatyzacji centralnej.
Źródło:
Archives of Mining Sciences; 2016, 61, 4; 793-807
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Czynniki współdecydujące o potencjale powstawania i rozwoju bio-filmu w systemach dystrybucji wody
Factors in the potential of biofilm formation and growth in water distribution systems
Autorzy:
Świderska-Bróż, M.
Powiązania:
https://bibliotekanauki.pl/articles/236880.pdf
Data publikacji:
2010
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
system wodociągowy
biofilm
stabilność chemiczna
stabilność biologiczna
środek dezynfekcyjny
water distribution system
chemical stability
biological stability
disinfectant
Opis:
Dokonano przeglądu problematyki powstawania biofilmu na wewnętrznej powierzchni rurociągów i instalacji wodociągowych. Omówiono przyczyny i skutki braku stabilności chemicznej i biologicznej wody w systemie wodociągowym. Podkreślono, że biofilm stwarza problemy techniczne i ekonomiczne, a przede wszystkim stanowi poważne zagrożenie jakości sanitarnej wody dostarczanej odbiorcom. Wykazano, że przyczyn współdecydujących o obecności i rozwoju biofilmu w systemach dystrybucji wody jest wiele. Związane są one nie tylko z jakością wody wprowadzanej do sieci wodociągowej, ale również z właściwościami materiałów instalacyjnych, warunkami hydraulicznymi panującymi podczas transportu wody do odbiorców, stanem technicznym i sanitarnym wszystkich elementów systemu dystrybucji oraz zachodzącymi w nim zjawiskami. Z uwagi na interakcje tych uwarunkowań, a przede wszystkim na najczęściej niemożliwą całkowitą ich eliminację, niezbędna jest skuteczna kontrola rozwoju biofilmu. Jest ona równoznaczna z zapewnieniem w całym systemie dystrybucji obecności środka dezynfekcyjnego, którego rodzaj i wymagana ilość mogą być różne w poszczególnych systemach dystrybucji wody. Spełnienie tego wymogu jest szczególnie trudne w przypadku rozległych i wyeksploatowanych systemach wodociągowych oraz tych, w których powstały już obrosty biologiczne.
The paper gives an account of the problems associated with the formation and growth of a biofilm on the internal surfaces of water pipes and water supply systems. Consideration is given to the causes and implications of chemical and biological instability of the water in the distribution system. Biofilms not only create technological and economic problems, but also pose a serious risk of deteriorating the quality of the water supplied to the user. The causes underlying the occurrence and growth of the biofilm in the water distribution system are manifold. Apart from those pertaining to the quality of the water entering the distribution system, they include the properties of the materials from which particular installations have been constructed, the hydraulic conditions that occur during water transport to the user, the technical and sanitary condition of all elements being part of the water distribution system, as well as any of the phenomena involved. Considering all the concomitant interactions - as well as the fact that in most instances they are difficult to eliminate to the extent desired (if at all) - a viable control of the biofilm's growth becomes a must. To efficiently control biofilm growth, it is necessary to provide the water distribution systems with continuous supply of disinfectants. (The type and quantity of the disinfectant may vary from one water distribution system to another.) Such requirement is difficult to fulfil specifically in the case of spacious, obsolete water-supply systems.
Źródło:
Ochrona Środowiska; 2010, 32, 3; 7-13
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detekcja małych wycieków w sieciach wodociągowych z zastosowaniem metody modelowania niepewności
Small leakage detection in water distribution systems with use of the model error modelling metod
Autorzy:
Przystałka, P.
Wyczółkowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/153681.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
sieci wodociągowe
detekcja wycieków bazująca na modelu
odporna detekcja wycieków
modelowanie niepewności
urban water supply networks
model-based leakage detection
robust leakage detection
uncertainty modelling
Opis:
W artykule przedstawiono badania dotyczące detekcji małych wycieków pojawiających się w sieciach wodociągowych. W celu detekcji uszkodzeń zastosowano schemat diagnozowania w oparciu o residua wygenerowane za pomocą przybliżonych modeli obiektu. Część decyzyjną realizującą ocenę wartości chwilowych residuów opracowano na podstawie metody modelowania niepewności. Uzyskane wyniki badań potwierdzają poprawność zastosowanego rozwiązania.
This paper considers the problem of small leakage detection in urban water supply networks. In order to detect leakage, the model-based fault diagnosis scheme was used. Nonlinear autoregressive exogenous models were applied to residual generation. A nonlinear part of the model was worked out with use of a multilayer perceptron neural network. Residual evaluation was realised basing on the model error modelling method. This method was modified to obtain a new scheme for adaptive threshold generation. In the case study reported in this paper the authors present the fault detection experiments with use of the industrial data set. The obtained results of small leakage detection in the considered water supply network confirm the effectiveness of the proposed approach. The paper is organized as follows. The first section deals with the introduction to the study. The second one includes a description of the proposed method. In the next section there are presented the results that were obtained by the authors. Finally, the paper ends with the conclusions.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 11, 11; 1307-1310
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies