Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "T1 relaxation" wg kryterium: Wszystkie pola


Wyświetlanie 1-7 z 7
Tytuł:
Cross Relaxation and Energy Transfer in Cs$\text{}_{2}$NaSm$\text{}_{x}$Eu$\text{}_{y}$Y$\text{}_{1-x-y}$Cl$\text{}_{6}$
Autorzy:
Luxbacher, T.
Fritzer, H. P.
Flint, C. D.
Powiązania:
https://bibliotekanauki.pl/articles/1945499.pdf
Data publikacji:
1996-07
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
33.5.-j
34.50.Gb
78.55.Hx
Opis:
Luminescence decay curves have been measured for the Sm$\text{}^{3+}$ $\text{}^{4}$G $\text{}_{5}\text{}_{/}\text{}_{2}$ → $\text{}^{6}$H $\text{}_{7}\text{}_{/}\text{}_{2}$ emission in the cubic crystal Cs$\text{}_{2}$NaSm$\text{}_{x}$Eu$\text{}_{y}$Y$\text{}_{1-x-y}$Cl$\text{}_{6}$ (x = 0.005 to x = 1, y = 0 to y = 0.99) over the temperature range 10 K to 300 K using pulsed laser excitation into the $\text{}^{4}$G $\text{}_{5}\text{}_{/}\text{}_{2}$ state of Sm$\text{}^{3+}$. The luminescence from the $\text{}^{4}$G $\text{}_{5}\text{}_{/}\text{}_{2}$ state of Sm$\text{}^{3+}$ is strongly quenched by both, cross relaxation to nearest-neighbour Sm$\text{}^{3+}$ ions and energy transfer to the $\text{}^{5}$D$\text{}_{0}$ state of Eu$\text{}^{3+}$. We interpret these processes in terms of a recently developed discrete shell model. The dependence of energy transfer from the Sm$\text{}^{3+}$ donor ion to Eu$\text{}^{3+}$ acceptor ions on y is readily studied and modelled. The temperature dependence shows that the cross relaxation occurs mainly by electric dipole vibronic-electric dipole vibronic interaction while in the energy-transfer process magnetic dipole allowed electronic contributions are also involved.
Źródło:
Acta Physica Polonica A; 1996, 90, 1; 161-168
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Lattice Parameter Relaxation during MBE of ZnTe/Cd$\text{}_{1-x}$Zn$\text{}_{x}$Te/Cd$\text{}_{0.5}$Zn$\text{}_{0.5}$Te Buffer Layers by RHLED and HRTEM
Autorzy:
Kret, S.
Karczewski, G.
Zakrzewski, A.
Dłużewski, P.
Dubon, A.
Wojtowicz, T.
Kossut, J.
Delamarre, C.
Laval, J. Y.
Powiązania:
https://bibliotekanauki.pl/articles/1933838.pdf
Data publikacji:
1995-10
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
61.16.Bg
61.14.Hg
68.35.-p
Opis:
The dynamics of the lattice relaxation processes were investigated using a reflection of a high energy electron diffraction analysis system during growth by molecular beam epitaxy of ZnTe/Cd$\text{}_{1-x}$Ζn$\text{}_{x}$Te/Cd$\text{}_{0.5}$Mn$\text{}_{0.5}$Te buffers on GaAs substrates. The variation of the lattice parameter recorded by the high energy electron diffraction during the growth was later confirmed by an analysis of high resolution transmission electron microscopy images. We report also on an observation of oscillations of the lattice parameter during the deposition of several first layers of ZnTe on CdTe.
Źródło:
Acta Physica Polonica A; 1995, 88, 4; 795-798
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Lycopene activity on lung and kidney cancer cells by T2 relaxation time 1 H Magnetic Resonance Imaging in vitro
Autorzy:
Pogoda, Katarzyna
Pucka, Maria
Tabarkiewicz, Jacek
Bober, Zuzanna
Aebisher, David
Galiniak, Sabina
Bartusik-Aebisher, Dorota
Powiązania:
https://bibliotekanauki.pl/articles/454731.pdf
Data publikacji:
2020-03-30
Wydawca:
Uniwersytet Rzeszowski. Wydawnictwo Uniwersytetu Rzeszowskiego
Tematy:
cell cultures
lung cancer
lycopene
kidney cancer
magnetic resonance imaging relaxation times
Opis:
Introduction. The paper presents the results of a study of cell cultures of lung cancer and kidney cancer using lycopene performed using clinical magnetic resonance imaging. Aim. The aim of the study was to evaluate lycopene activity on tumor cell cultures. Material and methods. For this purpose, MR tests were performed using the technique of determining transverse relaxation. Results. Described here studies demonstrated that lycopene may inhibit the growth of A549 and ACHN cell lines. Conclusion. We determine changes in spin lattice relaxavity T2 to monitor treatment of lung cancer cell line A549 and kidney cancer cell line ACHN cells treatment with lycopene.
Źródło:
European Journal of Clinical and Experimental Medicine; 2020, 1; 5-9
2544-2406
2544-1361
Pojawia się w:
European Journal of Clinical and Experimental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Składowe ośrodka jako czynnik zakłócający wynik pomiaru czasu relaksacji T1
The influence of medium components as a factor disturbing the result of the measurement of the relaxation time T1
Autorzy:
Truszkiewicz, Adrian
Aebisher, David
Bartusik-Aebisher, Dorota
Powiązania:
https://bibliotekanauki.pl/articles/2146785.pdf
Data publikacji:
2020
Wydawca:
Indygo Zahir Media
Tematy:
rezonans magnetyczny
relaksacja podłużna
relaksacja poprzeczna
czas relaksacji
magnetic resonance imaging
longitudinal relaxation
lateral relaxation
relaxation times
Opis:
Niniejsza praca ukazuje jedno z wybranych źródeł błędów, jakie znacznie powiększają niepewność wyniku określania czasu T1. Autorzy skupili się na wpływie ośrodka, w którym znajduje się badany obszar, na wartość czasu relaksacji. Pokazano na przykładzie fantomu, jak może się zmieniać wartość mierzonego parametru w zależności od właściwości składowych ośrodka. Założeniem każdej tomografii pozwalającej na obrazowanie dowolnych obiektów ze skończoną rozdzielczością przestrzenną jest to, iż piksel na całej swej powierzchni ma jednakową gęstość czy też skład chemiczny. W znakomitej większości przypadków jest to daleko posunięte uproszczenie, które pominięte w czasie analizy może doprowadzić do bardzo poważnych błędów interpretacji wyników prowadzonej diagnostyki czy też bardziej ogólnie badań.
This paper shows one of the selected sources of errors that significantly increase the uncertainty of the result of determining the time T1. The authors focused on the influence of the center in which the studied area is located on the value of the relaxation time. It was shown on the example of a phantom how the value of the measured parameter can change depending on the properties of the medium components. The assumption of each tomography that allows imaging of any objects with finite spatial resolution is that the pixel has the same density or chemical composition on its entire surface. In the vast majority of cases, it is a far-reaching simplification which, omitted during the analysis, may lead to very serious errors in the interpretation of the results of the diagnostics or, more generally, tests.
Źródło:
Inżynier i Fizyk Medyczny; 2020, 9, 6; 391--395
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
T1 and T2 Relaxation Times from Substantia Nigra in Parkinsons Disease and Control
Autorzy:
Kuliński, R.
Szlachta, K.
Gałązka-Friedman, J.
Friedman, A.
Powiązania:
https://bibliotekanauki.pl/articles/1360221.pdf
Data publikacji:
2014-04
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
87.19.L-
Opis:
The diagnosis of Parkinson's disease, and also other neurodegenerative disorders, is based on clinical examination. Many attempts are undertaken to find a test that could confirm this clinical diagnosis. Many hopes were attributed to magnetic resonance imaging but its importance remains obscure. The aim of this study was to compare T1 and T2 relaxation times from substantia nigra of patients with clinical diagnosis of Parkinson's disease and age-matched controls. A decrease of T2 (54.5 ± 1.4 ms vs. 58.0 ± 1.5 ms) in Parkinson's disease vs. control was found with confidence level of 5%. T1 did not differ significantly between Parkinson's disease and control (624 ± 17 ms vs. 614 ± 21 ms).
Źródło:
Acta Physica Polonica A; 2014, 125, 4; 869-871
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The usefulness of relaxation time using MRI measurements
Autorzy:
Bober, Zuzanna
Aebisher, David
Truszkiewicz, Adrian
Ożóg, Łukasz
Bartusik-Aebisher, Dorota
Powiązania:
https://bibliotekanauki.pl/articles/454698.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet Rzeszowski. Wydawnictwo Uniwersytetu Rzeszowskiego
Tematy:
Magnetic Resonance Imaging
T1 relaxation
field strength 1.5 Tesla
Opis:
Introduction. Magnetic Resonance Imaging methods are now frequently used for the analysis of the diseased tissue. These methods are based on the fact that the spin-lattice, T1 , and the spin-spin, T2 , relaxation times are different in diseased tissue as compared to that of normal tissue. Aim. Here we present measurements of spin-lattice relaxation time T1 on a Magnetic Resonance Imaging scaner with field strength 1.5 Tesla. Material and methods. Measurements of T1 relaxation time and analysis of literature. Results. We provide procedure for measurements of T1 relaxation time with field strength 1.5 Tesla and present a discussion of current applications.
Źródło:
European Journal of Clinical and Experimental Medicine; 2018, 3; 224-227
2544-2406
2544-1361
Pojawia się w:
European Journal of Clinical and Experimental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie metody magnetycznego rezonansu jądrowego do jakościowej oceny zwilżalności skał
Application of nuclear magnetic resonance method for qualitative assessment of rock wettability
Autorzy:
Klaja, Jolanta
Kulinowski, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/31343909.pdf
Data publikacji:
2023
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
skała hydrofilowa
skała hydrofobowa
zwilżalność mieszana
czas relaksacji podłużnej T1
przesunięcie czasu relaksacji
hydrophilic rock
hydrophobic rock
mixed wettability
longitudinal relaxation time T1
relaxation time shift
Opis:
Znajomość zwilżalności skał jest bardzo istotna, gdyż zjawisko to wpływa na ważne właściwości złoża, takie jak: nasycenie resztkowe ropą, względna przepuszczalność i ciśnienie kapilarne. Zrozumienie zwilżalności złoża ma kluczowe znaczenie dla określenia najbardziej efektywnych sposobów wydobycia ropy naftowej. W artykule przedstawiono metodę jakościowej oceny rodzaju zwilżalności skał, w której zasadniczą rolę odgrywają pomiary magnetycznego rezonansu jądrowego. Wykorzystuje się tutaj zróżnicowanie czasów relaksacji podłużnej T1, uwarunkowane rozkładem płynów w skale. Wykonanie badań wymagało użycia jednorodnego materiału skalnego. Badania zostały przeprowadzone na dwóch seriach próbek pobranych z dwóch bloków piaskowca: A (piaskowiec szydłowiecki biały) i B (piaskowiec szydłowiecki czerwony). Obydwa piaskowce charakteryzują się dużą jednorodnością, co potwierdzono pomiarami gęstości właściwej, gęstości objętościowej, porowatości helowej oraz badaniami na porozymetrze rtęciowym. Wykonano również standardowe pomiary czasów relaksacji poprzecznej T2 oraz wyznaczono skład mineralny dla reprezentatywnej próbki z piaskowca A i piaskowca B. Piaskowce te cechuje różny typ zwilżalności, co potwierdzono pomiarami współczynnika zwilżalności n standardową metodą elektryczną. W badaniach zastosowano dwa rodzaje płynów złożowych: solankę o mineralizacji 50 g/l oraz ropę naftową. W przypadku badania oddziaływania piaskowców z ropą naftową użyto dwóch rodzajów ropy o różnej lepkości dynamicznej: 7,43 mPa ·s i 1,12 mPa·s. Skały nasycone ropą były przechowywane przez kilka dni w temperaturze około 65°C celem doprowadzenia ich do stanu zwilżenia ropą. Pomiary czasu relaksacji podłużnej T1 wykonano zarówno dla obu serii próbek skał, jak też dla zastosowanych płynów złożowych. Skały badano w stanie pełnego nasycenia, w stanie resztkowego nasycenia oraz po nasiąkaniu (ang. imbibition). Wykonane badania wykazały, że dystrybucja czasów relaksacji podłużnej T1 dobrze obrazuje rozkłady wody i ropy w skałach i może być wykorzystana do jakościowego opisu rodzaju zwilżalności.
Knowledge of rock wettability is very important, as this phenomenon affects important reservoir properties such as residual oil saturation, relative permeability and capillary pressure. Understanding reservoir wettability is crucial for determining the most efficient ways to extract oil. This paper presents a method for qualitatively assessing the type of rock wettability in which nuclear magnetic resonance measurements play an essential role. The variation in longitudinal T1 relaxation times conditioned by the distribution of fluids in the rock was considered here. Performing the tests required the use of homogeneous rock material. The tests were carried out on two series of samples taken from two sandstone blocks: A (Szydłowiec white sandstone) and B (Szydłowiec red sandstone). Both sandstones are characterised by strong homogeneity, as confirmed by measurements of skeletal and bulk density, helium porosity and tests performed on a mercury porosimeter. Standard measurements of T2 transverse relaxation times were also made, and the mineral composition was determined for a representative sample from sandstone A and sandstone B. These sandstones have different types of wettability, as confirmed by measurements of the wettability coefficient n by the standard electrical method. Two types of reservoir fluids were used in the study: brine with 50 g/l mineralization and crude oil. Two types of oil with different dynamic viscosities, 7.43 and 1.12 mPa·s, were used to study the interaction of sandstones with crude oil. The oil-saturated rocks were stored for several days at a temperature of about 65ºC to bring them to a state of oil wetting. Longitudinal relaxation time T1 was measured for both series of rock samples and for the fluids used. The rocks were tested in the fully saturated state, in the residual saturated state and after imbibition. The performed tests showed that the distribution of T1 longitudinal relaxation times effectively illustrates the distributions of water and oil in rocks and can be used to qualitatively describe the type of wettability.
Źródło:
Nafta-Gaz; 2023, 79, 5; 291-299
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies