Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Piasecki, T." wg kryterium: Wszystkie pola


Tytuł:
Technical problems of mud pumps on ultra deepwater drilling rigs
Autorzy:
Bejger, A.
Piasecki, T.
Powiązania:
https://bibliotekanauki.pl/articles/359900.pdf
Data publikacji:
2013
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
drilling rig
mud pumps
damage to mud pump valves
Opis:
The article presents selected technical issues relating to drilling performed by a drillship, one type of drilling rigs. Basic problems encountered in the main function of such rigs − drilling a well − are failures of mud pumps. The authors investigate these pumps in operational conditions, aiming at development of a system for monitoring the technical condition of these pumps. Work on a diagnostic system is in progress that will permit to predict the condition of mud pump valves well in advance.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2013, 36 (108) z. 2; 13-16
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wybrane zagadnienia sterowania układem mikroprocesorowym DSP-FPGA prądnic przekształtnikowych pracujących równolegle w sieci okrętowej
Selected issues related to DSP-FPGA controlled inverters and electrical generators connected in parallel to ship’s electrical grid
Autorzy:
Kozak, M.
Piasecki, T.
Powiązania:
https://bibliotekanauki.pl/articles/376603.pdf
Data publikacji:
2015
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
prądnice elektryczne
falownik maszynowy
falownik sieciowy
praca równoległa przekształtników
Opis:
W pracy przedstawiono założenia teoretyczne i wyniki działania rzeczywistego układu eksperymentalnego prądnic przekształtnikowych pracujących równolegle w sieci okrętowej. Układ elektromaszynowy składający się z dwóch prądnic asynchronicznej klatkowej i synchronicznej szczotkowej włączony jest do sieci dystrybucyjnej poprzez przekształtniki. W układzie pracującym równolegle realizowany jest proces rozdziału mocy czynnej i biernej po stronie falowników sieciowych poprzez sterowanie układem DSP-FPGA.
The paper covers theoretical background and chosen experimental results for solidstate converters working in parallel with two different kind of electrical generators connected to ship electrical grid. Asynchronous cage generator along with synchronous generator are connected with ships grid throu line side VSC inverters. Appropriate control algorithm of digital signal processor DSP and field-programmable gate array FPGA is used to achieve active and reactive power distribution.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2015, 83; 121-128
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of CpG oligodeoxynucleotide stimulation on percentage of T and B cells in chicken
Autorzy:
Chrzastek, K.
Piasecki, T.
Wieliczko, A.
Powiązania:
https://bibliotekanauki.pl/articles/30568.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Opis:
TLR stimulation in chickens has been shown to play a role in the initiation and regulation of innate and adaptive immune responses. The aim of this study was to use flow cytometry to establish the percentage of T and B subset in blood and lymphoid organs in chicks after CpG oligodeoxynucleotide (ODN) stimulation. It was demonstrated that the percentages of CD3⁺, CD4⁺, TCRγ δ⁺ cells and Bu-1⁺MHC class II⁺ cells in blood 24 h post-injection were significantly higher than in the control groups. It was also shown that the percentages of CD3⁺ and CD4⁺ cells in the spleen at 48 h post-injection were significantly higher than in control groups. The percentage of Bu-1⁺ cells in the bursa of Fabricius after CpG ODN stimulation (98.38 ± 0.84) was significantly higher than that found in the non-CpG ODN control group (94.54 ± 2.51) (p ≤ 0.05). The results indicate that class B CpG ODN increases the percentage of both T (especially CD4⁺ cells) and B cells.
Źródło:
Polish Journal of Veterinary Sciences; 2013, 16, 3
1505-1773
Pojawia się w:
Polish Journal of Veterinary Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The assessment of the operational suitability of mud pumps on deep water drillships depends on maintenance strategy
Autorzy:
Piasecki, T.
Bejger, A.
Kozak, M.
Powiązania:
https://bibliotekanauki.pl/articles/135059.pdf
Data publikacji:
2016
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
drillships
mud pumps
maintenance strategies
valves
suction-discharge valves for mud pumps
drilling process
Opis:
This article examines the differences in the lifetime of mud pumps, which are part of the equipment on (ultra) deep-water drillships, depending on the strategy of maintenance. The authors conducted research on mud pumps to create an efficient diagnostic tool to help pumps operators on daily maintenance routines. We have created drilling process diagrams, one pertaining to the operation of mud pumps for which maintenance is carried out without technical supervision, the other including diagnostic maintenance. The diagrams show differences pump failure frequency.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2016, 46 (118); 49-53
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simple Wide Frequency Range Impedance Meter Based on AD5933 Integrated Circuit
Autorzy:
Chabowski, K.
Piasecki, T.
Dzierka, A.
Nitsch, K.
Powiązania:
https://bibliotekanauki.pl/articles/221804.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
impedance
converter
AD5933
system-on-a-chip
measurement
Opis:
As it contains elements of complete digital impedance meter, the AD5933 integrated circuit is an interesting solution for impedance measurements. However, its use for measurements in a wide range of impedances and frequencies requires an additional digital and analogue circuitry. This paper presents the design and performance of a simple impedance meter based on the AD5933 IC. Apart from the AD5933 IC it consists of a clock generator with a programmable prescaler, a novel DC offset canceller for the excitation signal based on peak detectors and a current to voltage converter with switchable conversion ratios. The authors proposed a simple method for choosing the measurement frequency to minimalize errors resulting from the spectral leakage and distortion caused by a lack of an anti-aliasing filter in the DDS generator. Additionally, a novel method for the AD5933 IC calibration was proposed. It consists in a mathematical compensation of the systematic error occurring in the argument of the value returned from the AD5933 IC as a result. The performance of the whole system is demonstrated in an exemplary measurement.
Źródło:
Metrology and Measurement Systems; 2015, 22, 1; 13-24
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prevalence of internal parasites in hamsters in pet shops in Wroclaw
Autorzy:
Polozowski, A.
Piasecki, T.
Kowalska, M.
Klimiuk, M.
Hormanska, M.
Powiązania:
https://bibliotekanauki.pl/articles/5890.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Parazytologiczne
Tematy:
prevalence
parasite
Giardia
Giardia duodenalis
animal infection
Trichosomoides nasalis
Syphacia
Hymenolepis nana
internal parasite
hamster
pet shop
Wroclaw city
Źródło:
Annals of Parasitology; 2016, 62, Suppl.
0043-5163
Pojawia się w:
Annals of Parasitology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Laboratory evaluation of rubber linings used in flue gas desulphurization plants by the gravimetric method and impedance spectroscopy
Laboratoryjna ocena wykładzin gumowych używanych w instalacjach odsiarczania spalin, metodą grawimetryczną i spektroskopii impedancyjnej
Autorzy:
Drela, I.
Masalski, J.
Nitsch, K.
Piasecki, T.
Szczygieł, B.
Powiązania:
https://bibliotekanauki.pl/articles/172882.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
odsiarczanie spalin
metoda grawimetryczna
metoda spektroskopii impedancyjnej
wykładzina gumowa
materiał powłokowy
flue gases desulphurization
gravimetric method
impedance spectroscopy method
rubber linings
lining material
Opis:
Special cells made of austenitic steel were employed to carry out accelerated tests of lining materials in the autoclave at elevated temperature and at a pressure gradient along the sample’s thickness. The tests were carried out on three kinds of rubber linings: prevulcanized soft two-ply lining based on bromobutyl rubber, selfvulcanizing two-ply lining based on bromobutyl rubber and prevulcanized lining based on chlorobutyl rubber. Distilled water, 1 % aqueous solution of HCl and aqueous solution containing 50 g/dm3 of sulphuric acid and 26 g/dm3 of sodium bisulphate (IV) were used as the working medium in the tests. The temperature of the working medium in the autoclave was kept at 110±2°C and the sample exposure time amounted to 48 hours. The change in the mass of the samples after the proper time of exposure in the autoclave was determined by the gravimetric method. A measuring system made up of an Agilent 4294A high-frequency impedance analyzer and a low-frequency impedance analyzer with a Keithley 428 current/voltage transducer was used to perform measurements in a frequency range from 0.1 mHz to 10 MHz at activation with an voltage amplitude of 1 V[RMS]. The impedance measurement results show that despite the severe corrosive conditions in the autoclave and the gain in the mass of the samples, the tested coating materials did not undergo significant degradation during their exposure and keep good dielectric and protective properties.
Zastosowano specjalne komórki ze stali austenitycznej, umożliwiające przeprowadzenie przyspieszonych badań materiałów powłokowych w autoklawie w warunkach podwyższonej temperatury i gradientu ciśnienia na grubości próbki. Badania wykonano dla trzech rodzajów wykładzin gumowych: wstępnie wulkanizowanej miękkiej wykładziny dwuwarstwowej na bazie kauczuku bromobutylowego, dwuwarstwowej samowulkanizującej się wykładziny na bazie kauczuku bromobutylowego i wstępnie wulkanizowanej wykładziny na bazie kauczuku chlorobutylowego). W badaniach jako medium robocze stosowano wodę destylowaną, 1% roztwór wodny kwasu solnego oraz roztwór wodny zawierający 50 g/dm3 kwasu siarkowego i 26 g/dm3 wodorosiarczanu (IV) sodu. Temperaturę medium roboczego w autoklawie utrzymywano w zakresie 110±2°C, a czas ekspozycji próbek wynosił 48 godz. Metodą grawimetryczną oznaczano zmianę masy próbek po odpowiednim czasie ekspozycji próbek w autoklawie, a wykorzystując system pomiarowy zestawiony z wysokoczęstotliwościowego analizatora impedancji Agilent 4294A oraz niskoczęstotliwościowego analizatora impedancji z przetwornikiem prąd-napięcie Keithley 428 wykonywano pomiary w zakresie częstotliwości od 0,1 mHz do 10 MHz przy pobudzeniu o amplitudzie napięcia przemiennego 1 V[RMS]. Otrzymane wyniki badań impedancyjnych pozwalają stwierdzić, że badane materiały powłokowe, pomimo ostrych warunków korozyjnych w autoklawie i zwiększenia masy próbek, nie uległy znaczącej destrukcji podczas ekspozycji i zachowały dobre właściwości dielektryczne i ochronne.
Źródło:
Archiwum Energetyki; 2012, 42, 2; 27-36
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impedance Sensors Made in PCB and LTCC Technologies for Monitoring Growth and Degradation of Pseudomonal Biofilm
Autorzy:
Chabowski, K.
Junka, A. F.
Piasecki, T.
Nowak, D.
Nitsch, K.
Smutnicka, D.
Bartoszewicz, M.
Moczała, M.
Szymczyk, P.
Powiązania:
https://bibliotekanauki.pl/articles/221326.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Pseudomonas aeruginosa
biofilm
interdigitated sensor
impedance spectroscopy
Opis:
The suitability of low-cost impedance sensors for microbiological purposes and biofilm growth monitoring was evaluated. The sensors with interdigitated electrodes were fabricated in PCB and LTCC technologies. The electrodes were golden (LTCC) or gold-plated (PCB) to provide surface stability. The sensors were used for monitoring growth and degradation of the reference ATCC 15442 Pseudomonas aeruginosa strain biofilm in invitro setting. During the experiment, the impedance spectra of the sensors were measured and analysed using electrical equivalent circuit (EEC) modelling. Additionally, the process of adhesion and growth of bacteria on a sensor’s surface was assessed by means of the optical and SEM microscopy. EEC and SEM microscopic analysis revealed that the gold layer on copper electrodes was not tight, making the PCB sensors susceptible to corrosion while the LTCC sensors had good surface stability. It turned out that the LTCC sensors are suitable for monitoring pseudomonal biofilm and the PCB sensors are good detectors of ongoing stages of biofilm formation.
Źródło:
Metrology and Measurement Systems; 2017, 24, 2; 369-380
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Synthesis of hydroxyapatite in the presence of anionic surfactant
Autorzy:
Kolodziejczak-Radzimska, A.
Samuel, M.
Paukszta, D.
Piasecki, A.
Jesionowski, T.
Powiązania:
https://bibliotekanauki.pl/articles/110560.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
hydroxyapatite
precipitation
anionic surfactant
Opis:
Hydroxyapatite was synthesized by precipitation method using an anionic surfactant (SDS) template, at ambient temperature and normal pressure. Phosphoric acid and disodium phosphate were used as a precursor of phosphorous, whereas calcium hydroxide and chloride were used as a precursor of calcium. The obtained hydroxyapatite was subjected to a wide range of physicochemical analysis using various measurement techniques. In order to get information about the properties of the obtained products, the following analysis of characteristics was performed: dispersion (NIBS), morphological (SEM), adsorptive (BET) and structural (XRD). Energy-dispersive X-ray spectroscopy and elemental analysis were also applied.
Źródło:
Physicochemical Problems of Mineral Processing; 2014, 50, 1; 225-236
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transient recovery voltage analysis for various current breaking mathematical models: shunt reactor and capacitor bank de-energization study
Autorzy:
Oramus, P.
Chmielewski, T.
Kuczek, T.
Piasecki, W.
Szewczyk, M.
Powiązania:
https://bibliotekanauki.pl/articles/140943.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
arc modelling
overvoltages studies
EMTP-ATP program
transients analysis
Opis:
Electric arc is a complex phenomenon occurring during the current interruption process in the power system. Therefore performing digital simulations is often necessary to analyse transient conditions in power system during switching operations. This paper deals with the electric arc modelling and its implementation in simulation software for transient analyses during switching conditions in power system. Cassie, Cassie-Mayr as well as Schwarz-Avdonin equations describing the behaviour of the electric arc during the current interruption process have been implemented in EMTP-ATP simulation software and presented in this paper. The models developed have been used for transient simulations to analyse impact of the particular model and its parameters on Transient Recovery Voltage in different switching scenarios: during shunt reactor switching-off as well as during capacitor bank current switching-off. The selected simulation cases represent typical practical scenarios for inductive and capacitive currents breaking, respectively.
Źródło:
Archives of Electrical Engineering; 2015, 64, 3; 441-458
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Słownik biograficzny lekarzy i farmaceutów -- ofiar drugiej wojny światowej. [T.1]
Autorzy:
Gliński, Jan B.
Data publikacji:
1997
Wydawca:
Wrocław : "Urban & Partner"
Tematy:
Piasecki Józef M. (1894-1944) biografia
Piasecki, Józef M.
Warszawa. Szpital Wolski ul. Płocka 26 biografie
Armia Krajowa. Komenda Główna. Oddział IV Kwatermistrzowski. Służba Zdrowia dowódcy
Armia Krajowa. Komenda Główna. Oddział IV Kwatermistrzowski. Służba Zdrowia dowódcy straty w ludziach słownik
Lekarze
Biografia
Słownik biograficzny
Opis:
Zastępca szefa sanitarnego KG AK. Zginął zastrzelony w Szpitalu Wolskim.
S. 323-325, Piasecki Józef Marian (1894-1944), lekarz chirurg, dyr. Szpitala Wolskiego, czł. ZWZ AK.
Dostawca treści:
Bibliografia CBW
Książka

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies