Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "PM10 concentration" wg kryterium: Wszystkie pola


Wyświetlanie 1-24 z 24
Tytuł:
Determination and evaluation of spatio-temporal trends on the example of PM10 concentration in Poland (2000−2018)
Autorzy:
Jackowska, Malwina
Fiedukowicz, Anna
Gąsiorowski, Jędrzej
Powiązania:
https://bibliotekanauki.pl/articles/1935074.pdf
Data publikacji:
2021
Wydawca:
Oddział Kartograficzny Polskiego Towarzystwa Geograficznego
Tematy:
PM10 concentration
spatio-temporal trends
interpolation
Opis:
Increasing amounts of rapidly growing data are the driving force behind proposing and automating new processing, enabling the extraction of useful information from data. One of such possibilities is determining trends to consider in terms of time and space. Thus far, the analysis of these aspects has been separate and lacked automated tools. Therefore, the authors proposed, implemented, and tested a tool for analyzing spatio-temporal linear trends. The tool was tested on PM10 concentration data in the years 2000-2018. The results, presented as cartographic visualization, were then evaluated, both in terms of time and space. The proposed approach facilitates analyzing spatio-temporal trends and assessing their accuracy; it can be developed using other types of analyzed trends or considering additional factors that influence the trend by using cokriging.
Źródło:
Polish Cartographical Review; 2021, 53; 37-48
2450-6974
Pojawia się w:
Polish Cartographical Review
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
PM10 Concentration Levels in the Żywiec Basin vs. Variable Air Temperatures and Thermal Inversion
Autorzy:
Wierzbińska, Monika
Kozak, Janusz
Powiązania:
https://bibliotekanauki.pl/articles/24201789.pdf
Data publikacji:
2023
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
airborne particulate
PM10
temperature inversion
low emission
Opis:
A number of cities in Poland have been coping with the problem of air pollution levels exceeding the allowable limits, with PM10 airborne particulate considered one of the most hazardous factors for human health. Poland ranks high among European countries with some of the highest levels of airborne particulate pollution, and the Polish cities regularly place high in the EU ranking of those with the highest PM levels (and benzo(a)pyrene, a toxic airborne polycyclic aromatic hydrocarbons, or PAHs). Airborne PM10 concentration levels greatly depend on the prevailing atmospheric and topographic conditions. Temperature inversion represents one of the unfavorable weather conditions and this article attempts to study the effect of thermal conditions prevailing in the Żywiec Basin on airborne PM10 particulate concentrations in immissions. The 2016–2021 winter (heating) seasons were analyzed for pollution emissions, especially those related to heating by the municipal sector and classified as “low emissions”, i.e. emissions from sources not higher than 40 meters. An analysis of the 2016–2021 heating seasons showed the air temperature exerted a significant effect on combustion processes (low emissions) within the Żywiec Basin. The difference between airborne PM10 particulate levels in immissions at temperatures both above and below zero ranged from 86 μg/m3 in the 2016–2017 heating season to 25 μg/m3 in the same period in 2020–2021. Average airborne PM10 particulate concentrations throughout the entire period analyzed stood at 41.3 μg/m3 for the typical temperature distribution in the elevation profile, whereas inversion almost doubled it (72.2 μg/m3).
Źródło:
Journal of Ecological Engineering; 2023, 24, 3; 47--54
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The impact of thermal inversion on the variability of PM10 concentration in winter seasons in Tricity
Autorzy:
Czarnecka, M.
Nidzgorska-Lencewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/207599.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
inversion
PM10
environment pollution
zanieczyszenie środowiska
inwersja
Opis:
The paper concerns the effect of thermal inversions on PM10 concentrations in winter seasons between 2004–2005 and 2012–2013 in Tricity. Temperature inversions were analyzed using aerological measurements timed at 00 UTC and 12 UTC obtained from the aerological station in Łeba. The PM10 concentrations were obtained from five Agency of Regional Air Quality stations in the Gdańsk metropolitan area (ARMAAG). The effect of inversion conditions on the variability of daily PM10 concentrations was assessed using single and multiple linear regressions. The unfavorable conditions of PM10 dispersion in the lower troposphere were mostly determined by elevated inversions, which occurred with comparable frequency, nearly 90%, during the day as well as at night. Surface inversions were recorded at a frequency of 30% at night and only 10% during day-time. The strongest adverse effect on PM10 concentrations and their variability during the period of calendar winter was found to be related to the thickness of surface inversions at night. A significant yet substantially less adverse effect during both day and night, however, was found to be related to the thickness of the lowest layer of upper inversion. The high location of the base of upper inversion, primarily during the day-time, contributed to a decrease in PM10 concentration.
Źródło:
Environment Protection Engineering; 2017, 43, 2; 157-172
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of Cluster Analysis in Defining the Meteorological Conditions Shaping the Variability of PM10 Concentration
Zastosowanie analizy skupień do wytypowania warunków meteorologicznych kształtujących zmienność stężeń pyłu zawieszonego PM10
Autorzy:
Czarnecka, M.
Nidzgorska-Lencewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/1818560.pdf
Data publikacji:
2015
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
cluster analysis
regression
PM10
meteorological conditions
analiza skupień
regresja
warunki meteorologiczne
Opis:
W pracy wykorzystano godzinne wyniki pomiarów stężeń pyłu zawieszonego PM10 oraz podstawowych elementów meteorologicznych rejestrowanych automatycznie w pięciu stacjach funkcjonujących w sieci pomiarowej Agencji Regionalnego Monitoringu Atmosfery Aglomeracji Gdańskiej (ARMAAG). Opracowaniem objęto okres kalendarzowej zimy (grudzień–luty) w latach 2004/2005–2009/2010. Zmienność stężeń zanieczyszczeń w warunkach pogodowych opisanych temperaturą i wilgotnością względną powietrza, ciśnieniem atmosferycznym oraz prędkością i kierunkiem wiatru, oceniono przy zastosowaniu analizy skupień, w tym metody k-średnich, z grupy metod niehierarchicznych. Kompleksowy wpływ warunków meteorologicznych na zmienność imisji pyłu PM10 w wyodrębnionych segmentach określono metodą liniowej regresji wielokrotnej, przy zastosowaniu procedury krokowej postępującej, na poziomie istotności p ≤ 0,05. Udział poszczególnych elementów pogody w kształtowaniu wielkości stężeń określono za pomocą współczynników regresji cząstkowej. Zastosowany algorytm wyodrębnił, w zależności od dzielnicy Trójmiasta, od 4 do 8 optymalnych skupień najwięcej – w Gdyni, odznaczającej się największą imisją pyłu zawieszonego. W większości przypadków głównym czynnikiem zróżnicowania pomiędzy wyodrębnionymi skupieniami był kierunek wiatru. W przeważającej części aglomeracji trójmiejskiej, w Gdyni i w Sopocie, największą imisję pyłu zawieszonego PM10 notowano przy wiatrach SE, podczas gdy w części południowej, w Gdańsku, podwyższone stężenia pyłu notowano przy wiatrach E we Wrzeszczu oraz W w Jasieniu. Skupienia grupujące największe stężenie PM10 charakteryzowały się w większości przypadków najniższą temperaturą powietrza i mniejszą prędkością wiatru, a ponadto często wyższym ciśnieniem i niekiedy nieco mniejszą wilgotnością względną powietrza, czyli warunkami panującymi przy pogodzie antycyklonalnej. Warunki meteorologiczne miały statystycznie istotny wpływ na stężenia PM10 we wszystkich skupieniach, ale zasadniczą rolę odgrywały temperatura powietrza oraz prędkość wiatru. Wiatr, niezależnie od kierunku, był na ogół efektywnym czynnikiem wentylacji przyczyniając się przede wszystkim do zmniejszenia zapylenia powietrza.
Źródło:
Rocznik Ochrona Środowiska; 2015, Tom 17, cz. 1; 40-61
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Próba zastosowania metody krigingu do wykonania map izolinii stężenia pyłu zawieszonego PM10 dla rejonu aglomeracji warszawskiej
Attempt of kriging method application for the creation of isoline maps of particulate matter PM10 concentration for Warsaw agglomeration
Autorzy:
Brandyk, A.
Majewski, G.
Porretta, L.
Powiązania:
https://bibliotekanauki.pl/articles/886740.pdf
Data publikacji:
2007
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
aglomeracja warszawska
interpolacje
kriging
metoda kriningu zob.krining
pyl zawieszony
stezenie pylow
zanieczyszczenia powietrza
zapylenie atmosfery
zmiennosc przestrzenna
Opis:
In this paper an attempt was made to apply kriging method for the creation of isoline maps of particulate matter PM10 concentration for Warsaw agglomeration for the following days: 20.02.2005, 21.02.2006, 22.02.2006, either distinguished by the presence of different meteorological conditions. Obtained empirical variograms of PM10 concentration values were of irregular course on account of a low number of measurement points availability (15 monitoring stations of particulate matter concentration). Those irregular courses of empirical variograms caused the arbitrary selection of theoretical functions for their approximation. Applying the arbitrarily selected functions for particulate matter concentration interpolation done by kriging method resulted in creating approximate PM10 concentration isoline maps. It was stressed that obtaining reliable isoline maps of related concentrations would require the availability of a wide range of measurement points.
Źródło:
Scientific Review Engineering and Environmental Sciences; 2007, 16, 2[36]
1732-9353
Pojawia się w:
Scientific Review Engineering and Environmental Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza zróżnicowania stężeń pyłu zawieszonego PM10 w świetle wyników pomiarów rozbudowanego systemu monitoringu jakości powietrza w Krakowie
AN ANALYSIS OF PM10 CONCENTRATION VARIABILITY IN VIEW OF THE MEASUREMENT RESULTS DERIVED FROM EXTENDED AIR QUALITY MONITORING SYSTEM IN KRAKOW
Autorzy:
Gorzelnik, Tomasz
Oleniacz, Robert
Powiązania:
https://bibliotekanauki.pl/chapters/16728999.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
monitoring jakości powietrza
PM10
zmienność stężeń
analizy porównawcze
rozbudowa systemu monitoringu
Opis:
W ramach niniejszej pracy została przeprowadzona analiza czasowego i przestrzennego zróżnicowania wyników pomiarów stężeń pyłu zawieszonego PM10 w powietrzu prowadzonych na terenie aglomeracji krakowskiej przez Wojewódzki Inspektorat Ochrony Środowiska w Krakowie. Posłużyła ona do oceny przydatności pięciu nowych stacji systemu monitoringu jakości powietrza mierzących tę substancję, uruchomionych w roku 2016 i 2017. Za główne kryterium przydatności przyjęta została wielkość różnic pomiędzy zbiorami danych, uzyskanymi z pomiarów na poszczególnych stacjach tego samego typu z uwzględnieniem także trzech starszych stacji monitoringowych, funkcjonujących przed rokiem 2016. Zaproponowany został wskaźnik obrazujący tempo zmian stężeń pyłu PM10, który obliczono dla różnych stacji i okresów uśredniania wyników. Zróżnicowanie serii danych wyrażone zostało także za pomocą współczynnika korelacji liniowej Pearsona dla stacji tego samego typu. W ocenie użyteczności stacji odniesiono się również do ich położenia względem źródeł emisji potencjalnie wpływających na poziom mierzonego na nich stężenia pyłu PM10.
In the paper an analysis of temporal and spatial diversification of PM10 air concentrations in the urban agglomeration of Krakow was conducted and presented using the measurements results from the air quality monitoring system operated by Voivodeship Inspectorate of Environmental Protection in Krakow. The analysis was a base of the usefulness assessment of five new air quality monitoring stations, launched in 2016 and 2017. The main criterion of usefulness were the differences between considered datasets, observed between each types of stations (traffic, urban background, industrial). In that comparison the three older stations were also taken into account. The pace of change index was proposed and calculated for different stations and periods. The PM10 concentrations’ variability was described by the Pearson correlation coefficient. In the research the location of measuring stations in relation to the main emission sources, potentially affecting the PM10 levels, was also discussed.
Źródło:
Aktualne problemy w inżynierii i ochronie atmosfery; 64-73
9788374930208
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rodzaje przebiegów dobowych stężeń PM 10 na wybranych stacjach monitoringu powietrza
TYPES OF PM10 DIURNAL CONCENTRATION COURSES ON SELECTED AIR MONITORING STATIONS
Autorzy:
Jasiński, Rafał
Borutko, Dariusz
Powiązania:
https://bibliotekanauki.pl/chapters/26917589.pdf
Data publikacji:
2023-04-03
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
PM10
powietrze
przebieg dobowy
zanieczyszczenie
air
diurnal course
pollution
Opis:
Przy pomocy algorytmu grupowania metodą k-średnich utworzono różne, możliwie odmienne skupienia przebiegów dobowych średnich jednogodzinnych wartości stężeń PM10. Przeprowadzono badania nad okresami występowania poszczególnych typów przebiegów dobowych stężeń PM10. Do analizy wybrano dane pochodzące z automatycznych stacji monitoringu powietrza zlokalizowanych w województwie śląskim, na których występowały najwyższe oraz najniższe poziomy stężeń PM10 w latach 2019-2021. Stwierdzono, że w rejonie silnie zurbanizowanym w przebiegach dobowych stężeń PM10 można wyróżnić wyraźne wzrosty stężeń w godzinach nocnych. Na obszarach mniej zanieczyszczonych poziomy stężeń PM10 mają podobny przebieg dobowy w ciągu całego roku kalendarzowego, różnice wynikają głównie z różnych wartości średnich. Do badań wykorzystano dane monitoringowe z lat 2019-2021 pozyskane z krajowej bazy danych jakości powietrza JPOAT2.0, udostępnione przez Główny Inspektorat Ochrony Środowiska.
Using the k-means clustering algorithm, various, possibly different, clusters of daily courses of one-hour mean values of PM10 concentrations were created. Studies have been carried out on the periods of occurrence of particular types of daily courses of PM10 concentrations. Data from automatic air monitoring stations located in the Śląskie Voivodeship with the highest and lowest levels of PM10 concentrations in 2019-2021 were selected for the analysis. It was found that in a highly urbanized area in the diurnal courses of PM10 concentrations, clear increases in night-time concentrations can be distinguished. In less polluted areas, the levels of PM10 concentrations follow a similar diurnal course throughout the calendar year, the differences mainly due to different mean values. The research used monitoring data from 2019-2021 obtained from the national air quality database JPOAT2.0 provided by the Chief Inspectorate for Environmental Protection.
Źródło:
Rozwiązania proekologiczne w inżynierii środowiska; 176-184
9788371939204
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Indoor-Outdoor Relations for PM10 Mass Concentration Based on University Building
Relacja outdoor-indoor dla stężenia masowego PM10 na przykładzie budynku uczelni
Autorzy:
Lenart, M.
Olszowski, T.
Powiązania:
https://bibliotekanauki.pl/articles/388248.pdf
Data publikacji:
2016
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
air contamination
aerosols
public building
PCA
zanieczyszczenia powietrza
aerozole
budynki użyteczności publicznej
Opis:
The determination of the level of pollutants and reciprocal relations “outside-inside” forms an important component in the study involving assessment and control of indoor air quality. This paper reports the results of a study with regard to the mass concentration of PM10 determined concurrently in the outdoor air surrounding a university building and inside the lecture rooms in it. The research project was undertaken in the cold season and registration included 83 independent observations with the duration of 90 minutes. The research applied a reference method involving measurements of PM10 mass concentration using gravimetric technique. The results were analyzed by application of non-parametric tests. For the purposes of classification of variables and assessment of the role of the specific variables, the analysis was based on the use of principal components. It was indicated that the mass concentration of particulate matter in the lecture rooms dśs not differ from the levels measured at the same time in the air surrounding the building only during the periods corresponding to periodic room ventilation. It was also found that the design and usage of the buildings, as well as the number and activity of humans determine the aerosanitary conditions in the enclosed spaces formed by the lecture rooms. It was observed that the mass concentration of particulate matter in the rooms is higher in the cold season. A statement was made that design solutions need to be implemented with the purpose of using intelligent ventilation systems.
Określenie udziału źródeł zanieczyszczeń oraz wzajemnej relacji „outside-inside” jest istotnym problemem w szacowaniu i kontroli jakości powietrza wewnętrznego. Artykuł przedstawia wyniki badań nad stężeniem masowym PM10 określonym jednocześnie w okalającym budynek powietrzu zewnętrznym oraz w salach dydaktycznych uczelni wyższej. Projekt badawczy przeprowadzono w sezonie chłodnym, rejestrując 84 niezależne, 90-minutowe obserwacje. W badaniach wykorzystano, opartą na grawimetrii, referencyjną metodę pomiaru stężenia masowego PM10. Rezultaty badań przeanalizowano przy użyciu testów nieparametrycznych. W badaniach, celem klasyfikacji zmiennych i oszacowania odpowiedzialności poszczególnych czynników, posłużono się analizą składowych głównych. Wykazano, że wartości stężenia masowego pyłu zmierzonego w salach dydaktycznych nie różnią się od poziomów określonych jednocześnie w okalającym budynek powietrzu zewnętrznym wyłącznie podczas okresowego wietrzenia pomieszczeń. Stwierdzono, że konstrukcja oraz sposób użytkowania budynku a także liczba i aktywność osób w znaczący sposób determinują warunki aerosanitarne w pomieszczeniach zamkniętych. Wykazano, że w sezonie chłodnym stężenie masowe pyłu zawieszonego jest wyższe w pomieszczeniach. Złożono postulat przyjęcia rozwiązań polegających na implementacji inteligentnych systemów wentylacyjnych.
Źródło:
Ecological Chemistry and Engineering. A; 2016, 23, 2; 127-137
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ warunków meteorologicznych oraz cyrkulacji atmosferycznej na stężenie PM10 we Wrocławiu
Influence of meteorological conditions and atmospheric circulation on PM10 mass concentration in Wroclaw
Autorzy:
Drzeniecka-Osiadacz, A.
Netzel, P.
Powiązania:
https://bibliotekanauki.pl/articles/126936.pdf
Data publikacji:
2010
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
PM10
warunki meteorologiczne
warstwa graniczna atmosfery
sodar
Wrocław
meteorological conditions
atmospheric boundary layer
Opis:
W ramach Badań Klimatu Miasta w Zakładzie Klimatologii i Ochrony Atmosfery prowadzone są pomiary pyłu zawieszonego, czynników meteorologicznych oraz stanu warstwy granicznej. Do monitoringu pyłu PM10 wykorzystywany był analizator TEOM-1400a. W artykule przedstawiono analizę wpływu warunków meteorologicznych na koncentrację pyłu zawieszonego PM10 ze szczególnym uwzględnieniem struktury warstwy granicznej i jej dynamiki w okresie od grudnia 2008 do maja 2009 r. Dobowa zmienność stężenia PM10 wynikała przede wszystkim z warunków mezoskalowych oraz stanu termodynamicznego najniższej części atmosfery, co w konsekwencji prowadziło do tworzenia się kilkudniowych epizodów. Szczegółowej analizie poddano sytuacje podwyższonych stężeń zanieczyszczeń. W chłodnej porze roku dni z bardzo wysokimi stężeniami pyłu związane były z pogodą antycyklonalną oraz równowagą stałą w dolnej części warstwy granicznej atmosfery. Maksymalne średnie dobowe stężenie, jakie zanotowano w tym czasie, wynosiło około 100 µg·m–3, a 1-godzinne przekroczyło 230 µg·m–3.
In resent years, airborne particulate matter with diameter less than 10 µm is pollutant of large concern due to its adverse effect on human health. Many studies report association between PM10 concentration and mortality. The EU Directive regulate particulate matter concentrations (Directive 1999/30/EC) and encouraged the Member State to promote research and measurement of particulate matter, as well as prepare strategies to improve air quality. The first step to solve these tasks is understanding the mechanisms of dispersion and accumulation of pollutant. Within Urban Climate Researches of The Department Climatology and Atmosphere Protection Wroclaw University (51°07' N, 17°05' E) the continuous monitoring of PM10 mass concentration, meteorological variables and structure of atmospheric boundary layer were conducted. PM10 concentration was measured by TEOM 1400a series. The automatic weather station was used to measure the meteorological variables (air temperature, pressure, wind speed, wind direction, incoming solar radiation). Sodar sounding and vertical profile of temperature obtained from free balloon sounding completed the data. The data were recorded with resolution of 1 min. In this paper temporal variation of PM10 concentration during the period from December 2008 to May 2009 in relation to meteorological conditions are shown. Daily variations of PM10 concentrations were driven particularly by meso-scale conditions and thermodynamic state of the lower part of ABL, which resulted in a few days’ episodes. Some episodes of high level of particulate matter were analysed in detail. The winter episodes were characterize by systematic increase in mass concentration due to stagnation condition. The maximum values of daily average PM10 concentration was about 100 µg·m–3, but the hourly maximum exceeded 230 µg·m–3. The key factor favoured that situations was large high pressure system, with a centre located in eastern Europe, which produced weather of low wind, long-lasting inversion and lack of precipitation. During spring high level of PM10 mass concentration was recorded rather seldom. These short-time situations were caused by strong wind after dry and calm period.
Źródło:
Proceedings of ECOpole; 2010, 4, 2; 343-349
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The concentration level of PM10 in southern Poland (Katowice, Kraków, and Rzeszów) during the year 2018
Autorzy:
Qor-el-aine, Achraf
Béres, András
Géczi, Gábor
Powiązania:
https://bibliotekanauki.pl/articles/2086189.pdf
Data publikacji:
2021
Wydawca:
Państwowa Wyższa Szkoła Zawodowa w Tarnowie
Tematy:
PM10
Coal Mines
HYSPLIT trajectory frequency
analysis
Katowice
Cracow
Rzeszow
kopalnia węgla
częstotliwość trajektorii HYSPLIT
analiza
Kraków
Rzeszów
Opis:
Human health and food quality are greatly affected by the state of the ambient air. In the European Union, Poland is considered as a country that has the most polluted air. The level of PM10 concentration exceeds the EU limit value in almost all the areas of Poland, but higher concentrations are registered in the southern regions, which are considered as the coal heartlands. Katowice, Kraków, and Rzeszów are three big cities in the southern part of Poland and are surrounded by coal mining industries. High PM10 concentrations are usually registered in these three cities, especially in the winter period. In 2018, the peak PM10 daily concentration occurred in the three cities at the same period (04/03/2018 in Rzeszów, 05/03/2018 in Kraków, and 05/03/2018 in Katowice). The aim was to identify the effect of each of the 8 coal mines that exist in Poland on the level PM10 concentration for the first week and March where the highest daily PM10 concentration for the year 2018 was registered. Using HYSPLIT Frequency analysis, the results showed that 100% of the particles coming from Bełchatów, Bolesław Śmiały, Halemba, Jas-Mos, Pniówek and Marcel Coal Mines hit Katowice region, and 10% from Bogdanka. While for Kraków, it was affected by 100% of the particles that are originated from Bolesław Śmiały, Pniówek, Halemba, and Jas-Mos Coal Mines and 10% Bogdanka, Bełchatów, and Marcel Coal Mines. Moreover, Rzeszów was the least affected city by the coal mines, 10% of the particles coming from Bogdanka, Bełchatów, Jas-Mos and Marcel, Halemba, and Pniówek Coal Mines attributed to high PM10 concentration during the first week of March 2018. Katowice and Kraków are more affected by the coal mines industry, Particulate Matter particles originating from the coal mines sites contribute to the high level of PM10 concentration.
Źródło:
Science, Technology and Innovation; 2021, 14, 3; 27--34
2544-9125
Pojawia się w:
Science, Technology and Innovation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie GIS do analizy przestrzennej stężeń pyłu PM2.5 oraz PM10 na terenie województwa dolnośląskiego
Application of GIS technique for pm2.5 and pm10 concentrations spatial analysis in the province of lower silesia
Autorzy:
Sówka, I.
Łągiewka, A.
Zwoździak, A.
Skrętowicz, M.
Nych, A.
Zwoździak, J.
Powiązania:
https://bibliotekanauki.pl/articles/1819452.pdf
Data publikacji:
2011
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
województwo dolnośląskie
GIS
stężenie pyłu PM2.5
stężenie pyłu PM10
Lower Silesia
concentration of PM2.5
concentration of PM10
Opis:
Zmienność w czasie i przestrzeni danych stanowi kluczowy element różnych zjawisk zachodzących w środowisku przyrodniczym. W celu zbadania zmienności buduje się bazy danych, w których jedną z cech jest lokalizacja. W dobie automatyzacji i informatyzacji bazy danych to niezbędny element funkcjonowania wielu instytucji państwowych oraz firm prywatnych. Problematyczne wydaje się być przedstawienie informacji zawartych w bazach w taki sposób, by zmiany przed-stawione za pomocą liczb były łatwe i szybkie w analizowaniu. Z pomocą przychodzą rozwiązania technik GIS (z ang. Geographic Information System), stosowane obecnie na szeroką skalę w wielu branżach m.in. w transporcie, budownictwie, energetyce oraz w inżynierii i ochronie środowiska [1÷8]. Celem niniejszej pracy była wizualizacja i analiza przestrzenna danych dotyczących zanieczyszczenia powietrza atmosferycznego pyłem zawieszonym PM10 i PM2.5 na terenie województwa dolnośląskiego przy zastosowaniu techniki GIS.
Variability of data in time and space is a key element of the different phenomena occurring in the natural environment. In order to investigate the variability a databases in which one of the features is the location are built up. In the era of automation and computerization the databases are an essential element for the functioning of many public institutions and private companies. Problematic seems to be to present the information in databases in such a way as to amendments submitted by the numbers were easy and quick to analyze. In such a case the GIS technique can be helpful. The method of implementation of spatial analysis using ArcGIS soft-ware package was presented. It consisted of obtaining data on concentrations of pollutants, processed for the purposes of the program, the appropriate data management, analysis and graphical presentation of results. There were used functions that were needed to create the area and point type map layers. By use of the area type layers, zones according to which the concentrations classification was conducted. And with a point type layers measurement points used in the study were presented. For each layer is assigned the characteristics of the resource database, which allowed their subsequent interpretation by the spatial analysis. By combining point-type layer with polygons characteristics for the relevant areas was averaged. Ability to set the layer properties has allowed for classification and presentation of data assigned to them. In this study spatial analysis were conducted to show the possibility of using geoinformation techniques in monitoring of concentrations of selected air pollutants (PM10 and PM2.5). Developed data of measurements of concentrations of PM10 and PM2.5 from the beginning of 2009 till September of 2010 were made available by the Regional Inspectorate for Environment Protection in Wroclaw. Using this set of data it was possible to present and to characterize air pollution by particulate matter PM10 and PM2.5 in the Lower Silesia province. It was observed that the zones characterized by the highest levels in selected averaging periods (monthly and annual) were: District Kłodzko, Wałbrzych, the city of Legnica and Wrocław agglomeration. In 2009, the observed average concentrations exceeded the limit of PM10 (40 ?g/m3) in the Kłodzko. The concentrations of PM10 in the range from 30 to 40 ?g/m3 near Legnica, district of Wałbrzych and Wrocław agglomeration were observed. In 2010, the concentrations of PM10 in ambient air over three mentioned areas has been exceeded the limit values. In the case of PM2.5 annual average concentration allowed value (25 ?g/m3) was exceeded in the district of Wałbrzych and Wrocław agglomeration. It was also examined the impact of volcanic eruption of Eyjafjallajökull in Iceland, which took place on April, 14th (2010), on air quality in the Lower Silesia province. The changes in concentrations of PM10 and PM2.5 for 14 and 18 of April 2010 were studied. Prepared maps indicated that the PM 2.5 concentrations four days after the eruption, when the air space for air transportation in most countries in Europe, including Polish, was closed, over most concerned areas were lower compared with April 14th 2010. For a fraction of PM10 there were no significant changes in concentrations in Lower Silesia province.
Źródło:
Rocznik Ochrona Środowiska; 2011, Tom 13; 1667-1678
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
KORELACJA ZMIAN STĘŻEŃ PYŁÓW ZAWIESZONYCH PM10 Z TYPAMI CYRKULACJI ATMOSFERYCZNEJ W KONINIE W LATACH 2012–2016
Autorzy:
Karczewska, Kaja
Kolendowicz, Leszek
Półrolniczak, Marek
Forycka–Ławniczak, Hanna
Powiązania:
https://bibliotekanauki.pl/articles/943775.pdf
Data publikacji:
2018
Wydawca:
Poznańskie Towarzystwo Przyjaciół Nauk
Tematy:
particulate matter PM10
atmospheric circulation
concentration levels analysis
Konin
Polska
Opis:
The subject of the paper is the influence of atmospheric circulation on the content of suspended PM10 in the air in Konin. For this purpose dust concentrations from the period 2012–2016 were generally characterized. PM10 particulate matter concentration average hourly data were obtained from the Main Inspectorate of Environmental Protection website. Based on these data, long-term, seasonal and daily changes in the PM10 concentration in the atmosphere were investigated. The study analysed the daily variability of the PM10 suspended particulate matter concentration to present seasonal differences (in hot and cold seasons). In order to determine the influence of atmospheric circulation on the PM10 particulate matter concentration, the concentration levels data were compared with the types of circulation prevailing on the same day. In this study according to synoptic maps the days with maximum and minimum concentrations PM levels were analysed. It was found which type of meteorological circulation is conducive to higher levels concentrations of particulate matter PM10, and which has a positive effect on the quality of the air in Konin.
Źródło:
Badania Fizjograficzne Seria A - Geografia Fizyczna; 2018, 9(69); 45-64
2081-6014
Pojawia się w:
Badania Fizjograficzne Seria A - Geografia Fizyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przystosowanie laserowego analizatora uziarnienia LAU-11 do pomiarów wielkości PM10 i PM2,5
Adaptation of laser particle size analyzer LAU-11 for measuring the concentration of PM10 and PM2,5 in the dust
Autorzy:
Paprotny, W.
Adamczyk, Z.
Powiązania:
https://bibliotekanauki.pl/articles/392127.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Ceramiki i Materiałów Budowlanych
Tematy:
analiza składu ziarnowego
analizator laserowy
analizator LAU-11
zakres pomiarowy
cząstka pylasta
particle size analysis
laser analyzer
analyzer LAU-11
measuring range
particle matter
Opis:
Laserowy analizator uziarnienia LAU-11 swą historią sięga lat osiemdziesiątych XX w., a dokładniej konstrukcji granulometru laserowego GL-04, opracowanego w Zakładzie Urządzeń i Pomiarów Cieplnych Instytutu Mineralnych Materiałów Budowlanych [1-3]. Granulometr miał zakres pomiarowy od 3 do 90 ?m podzielony na 6 frakcji i obsługiwany był przy pomocy mikrokomputera ZX Spectrum Plus. Pomiar światła w widmie rozproszonym wykonywany był w 10 punktach widma. Kolejne konstrukcje miały na uwadze rozszerzenie zakresu pomiarowego oraz zwiększenie liczby frakcji. W ten sposób powstały konstrukcje laserowego analizatora uziarnienia LAU-11 i LAU-14 mające po 16 detektorów światła i zakres pomiarowy od ok. 1 do 200 ?m. Różnica między LAU-11 i LAU-14 zasadzała się w konstrukcji głowicy pomiarowej. LAU-11 posiada głowicę składającą się z elementów dyskretnych - fototranzystorów, przy czym pierwsze cztery detektory (najbliższe osi optycznej) wyposażone są w światłowody o średnicy wewnętrznej 0,25 mm. Elementem pomiarowym w LAU-14 jest natomiast linijka CCD składająca się z 512 pixeli pomiarowych, z których wykorzystywanych jest 16 elementów.
Laser particle size analyzer LAU-11 began its history in the late 80’s on the design of the instrument GL-04, developed in the Department of Plant and Thermal Measurements IMMB [1] to [3]. GL-04 had a range of 3 to 90 mim divided into 6 factions and was supported by a microcomputer ZX Spectrum Plus. Measurement of scattered light in the spectrum was performed at 10 points in the spectrum. Other structures were the enlargement of measurement range and increasing the number of fractions. In this way, the resulting structures Laser particle size analyzer LAU-11 and LAU-14 to 16-light detectors and range from about 1 micrometer to 200 mim. The difference between the LAU-11 and LAU-14 design was based in the head. LAU-11 has a head composed of discrete components – phototransistors, the first four detectors (closest to the optical axis) are equipped with optical fibers of internal diameter 0,25 mm. Sensing element in the LAU-14 is composed and the CCD line a measurement of 512 pixels, which are used 16 parts. Was produced over a dozen instruments and GL-04 Laser particle size analyzers LAU-11 and LAU-14. In Opole Branch of the Institute’s LAU-11.
Źródło:
Prace Instytutu Ceramiki i Materiałów Budowlanych; 2012, R. 5, nr 11, 11; 76-87
1899-3230
Pojawia się w:
Prace Instytutu Ceramiki i Materiałów Budowlanych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Emisja stałych cząstek z liniowych źródeł zanieczyszczenia jako główny czynnik wpływający na poziom stężenia pyłu zawieszonego PM10, PM2,5, PM1,0 w powietrzu atmosferycznym aglomeracji warszawskiej
Emissions of Solid Particles from Linear Sources of Pollution as a Major Factor in the Level of Concentration of PM10, PM2.5, PM1.0 in Ambient Air of Warsaw Agglomeration
Autorzy:
Dmochowski, D.
Dmochowska, A.
Biedugnis, S.
Powiązania:
https://bibliotekanauki.pl/articles/1818580.pdf
Data publikacji:
2015
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
emisja pyłów ze źródeł liniowych zanieczyszczenia
stężenie pyłu PM10
PM2.5
PM1.0
dust emissions from linear sources of pollution
level concentrations of PM10
Opis:
The paper presents the results of the research into the dust from the linear sources of pollution emitted close to the right-bank Warsaw allotments. The results of dust measurements and its fraction show that the legal limits of the concentration of dusts floating in the atmospheric air for the measurement points are exceeded. The points are located in the nearest distance from Trasa Łazienkowska and alley Waszyngtona – two busy roads in the right-bank Warsaw. The results show that the dust and its fractions can pose the ecological safety hazards and can constitute a significant reduction of health safety of both allotments users and local residents.
Źródło:
Rocznik Ochrona Środowiska; 2015, Tom 17, cz. 2; 1403-1412
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mobilne laboratorium do analizy stanu zanieczyszczenia powietrza pyłem PM10, PM2,5 i PM1 w wybranych lokalizacjach
MOBILE LABORATORY FOR ASSESSMENT OF AMBIENT CONCENTRATION OF PARTICULATE MATTER FRACTIONS PM10, PM2,5 AND PM1 AT SELECTED LOCALIZATIONS
Autorzy:
LICKI, Janusz
LASIEWICZ, Marek
KOWALSKI, Marek
Powiązania:
https://bibliotekanauki.pl/chapters/1965508.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Opis:
W Narodowym Centrum Badań Jądrowych w Świerku uruchomiono mobilne laboratorium do pomiarów jakości powietrza. Skompletowano aparaturę do pomiarów stężeń masowych frakcji PM10 i PM2,5 pyłu zawieszonego oraz liczebności cząstek tworzących frakcję PM1. Do pomiaru stężeń trzech gazowych zanieczyszczeń powietrza: tlenków azotu, tlenku węgla i ozonu użyto zestawu referencyjnego analizatorów firmy Teledyne API wraz z systemem ich kalibracji. Całość ulokowano w dedykowanym klimatyzowanym kontenerze pomiarowym osadzonym na podwoziu jezdnym. Na dachu kontenera zamocowano czerpnie z odpowiednimi głowicami separacyjnymi, którymi transportowane jest powietrze do poszczególnych pyłomierzy wewnątrz kontenera. W czasie trwania pomiarów jakości powietrza rejestrowane są następujące parametry meteorologiczne: prędkość i kierunek wiatru, temperatura i wilgotność powietrza oraz ciśnienie atmosferyczne. Parametry te są określane przy użyciu dwóch stacji meteorologicznych zainstalowanych na dachu kontenera. Mobilne laboratorium zostało użyte do pomiarów jakości powietrza w rejonie węzła drogowego Alei Krakowskiej i Południowej Obwodnicy Warszawy. W czasie tygodniowych pomiarów zarejestrowano 7 razy przekroczenie dopuszczalnego dobowego stężenia PM10 oraz wysokie liczebności ultradrobnych cząstek.
The mobile laboratory has tested air quality in the region of the crossroads of Aleja Krakowska street with South Ring Road of Warsaw. The one week continuous measurements were performed. The high mass concentrations of PM10 and PM2,5 were recorded. In each measuring day the recorded 24-hour mass concentration of PM10 exceeded the limit value for one day (50 μg/m3). In this region, high number concentrations of ultrafine and fine particles were recorded. The average one day number concentration of all ultrafine particles was of 352 629 particles per cubic centimeter and fine particles was 176 277, respectively.
Źródło:
Powietrze atmosferyczne. Jakość – zagrożenia – ochrona; 223-232
9788374939423
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Warunki termiczne a stężenie pyłu zawieszonego w powietrzu atmosferycznym zimą w wybranych miastach Polski
Thermal conditions and concentration of particulate matter in atmospheric air in winter in selected Polish cities
Autorzy:
Rawicki, K.
Powiązania:
https://bibliotekanauki.pl/articles/134837.pdf
Data publikacji:
2016
Wydawca:
ADVSEO
Tematy:
PM10
air temperature
air pollution
Opis:
The aim of the study was to assess the impact of thermal conditions on emission of PM10 in the atmosphere during the winter period in selected Polish cities. The basis of the work were average daily PM10 and air temperature measurement results, which were made in six cities during three of calendar winters (December-February) in 2011–2014. It has been shown that every decrease in temperature during the winter affects the increase in the concentration of PM10 in ambient air in most of the analyzed cities. The greatest role of air temperature in shaping emission of the fraction of particulate matter variability was found in a relatively cool winter 2011/2012, when the number of days with oversize levels of contamination ranged from 7 in Suwałki to even 46 in Nowy Sącz. The smallest impact of this weather element was found during a warm winter 2013/2014.
Źródło:
Technical Issues; 2016, 1; 59-65
2392-3954
Pojawia się w:
Technical Issues
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sezonowa zmienność stężenia pyłu zawieszonego oraz jakości powietrza na terenie miasta Sosnowiec
Seasonal Variability of Concentration and Air Quality of Ambient Particulate Matter in Sosnowiec City
Autorzy:
Cembrzyńska, Jolanta
Krakowiak, Ewa
Brewczyński, Piotr Z.
Powiązania:
https://bibliotekanauki.pl/articles/1177517.pdf
Data publikacji:
2015
Wydawca:
Instytut Medycyny Wsi
Tematy:
"PM10"
"PM2
"indeks jakości powietrza"
"pył zawieszony"
5"
Opis:
Introduction: Exposing the population to more than standard concentration of particulate matter (PM) is a crucial factor shaping the public health on urbanized areas both in Europe and Poland. In most cases, exceeded air quality standards relate to the winter period, in which there has been the greatest amount. Many studies have indicated, that exposure to PM can cause adverse health effects. Human exposure especially to fine particles (with an aerodynamic diameter less than 2.5 µm), causes risk of cardiovascular and respiratory diseases, due to daily mortality and hospital admissions. Various types of epidemiological studies have indicated, that ambient air pollution is responsible for increasing risk of lung cancer. For this reason, in 2013 The International Agency for Research on Cancer (IARC) classified outdoor air pollution and particulate matter as carcinogenic to humans (Group 1). Aim of the study: The purpose of the study was assessment of air pollution (PM10, PM2,5) in the winter and summer season 2013, in relation to limit values specified to protect human health. In addition, was performed a classification of air quality conditions according to the categories of modified air quality index, used in the Silesian Providence, to inform the public about the rate of exposure and the possibility of appearing of potential health effects associated with different levels of air pollution. Results: Statistically significant (p<0.05) higher concentration of PM10 and PM2,5 occurred in the winter season. The average concentration of PM10 was 62 µg/m3 and was twice higher than in the summer season. The mean concentration of PM2,5 was 52 µg/m3 and more than twice exceeded the concentration values obtained during the summer months. For the most part of the winter season (50-70% days) dominated „high index”, provides poor air quality on area city.
Wstęp: Narażenie populacji na ponadnormatywne stężenia pyłu zawieszonego jest istotnym czynnikiem kształtującym zdrowie publiczne na terenach zurbanizowanych zarówno w Polsce, jak i Europie. W większości przypadków, przekroczenia norm jakości powietrza odnoszą się do okresu zimowego, w którym notuje się ich największą częstość. Jak wskazują wyniki licznych badań, z ekspozycją środowiskową na podwyższone stężenia pyłu zawieszonego wiąże się nasilenie negatywnych skutków zdrowotnych. Narażenie człowieka, zwłaszcza na cząstki drobne (o średnicy aerodynamicznej mniejszej niż 2,5 µm), zwiększa ryzyko rozwoju chorób układu krążenia i układu oddechowego, w powiązaniu ze wzrostem hospitalizacji oraz obniżeniem średniej długości życia. Badania epidemiologiczne wykazały ponadto, że zanieczyszczenie powietrza tym czynnikiem zwiększa ryzyko zachorowania na raka płuc. Z tego powodu w 2013 roku Międzynarodowa Agencja Badań nad Rakiem (IARC) zaklasyfikowała pył zawieszony jako czynnik rakotwórczy dla ludzi (Grupa 1). Cel pracy: Celem badań było określenie stopnia zanieczyszczenia powietrza pyłem zawieszonym (PM10, PM2,5) w sezonie zimowym i letnim 2013 roku, w odniesieniu do standardów jakości powietrza ustalonych ze względu na ochronę zdrowia ludzi. Ponadto przeprowadzono klasyfikację stanu aerosanitarnego powietrza w oparciu o zmodyfikowany indeks jakości powietrza, stosowany w województwie śląskim, do informowania społeczeństwa o wskaźniku narażenia oraz możliwości wystąpienia potencjalnych skutków zdrowotnych związanych z różnym poziomem zanieczyszczeń. Wyniki: Istotnie wyższe statystycznie (p<0,05) stężenia pyłu zawieszonego PM10 oraz PM2,5 wystąpiły w sezonie zimowym. Średnie stężenie pyłu PM10 wyniosło 62 µg/m3 i było dwukrotnie wyższe niż w sezonie letnim. Średnie stężenie pyłu PM2,5 wyniosło 52 µg/m3 i ponad dwukrotnie przekraczało wartości stężeń uzyskane w okresie letnim. W przeważającej części sezonu zimowego dominował ponadto „wysoki wskaźnik”, świadczący o złej jakości powietrza na terenie miasta.
Źródło:
Medycyna Środowiskowa - Environmental Medicine; 2015, 18, 4; 27-35
1505-7054
2084-6312
Pojawia się w:
Medycyna Środowiskowa - Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ typów cyrkulacji na stężenie pyłu zawieszonego (PM10) w zimie na wyżynie śląskiej
Impact of circulation types on the concentration of particulate matter (PM10) in winter at the Silesian Upland
Autorzy:
Radomski, J.
Powiązania:
https://bibliotekanauki.pl/articles/272222.pdf
Data publikacji:
2008
Wydawca:
Górnośląska Wyższa Szkoła Pedagogiczna im. Kardynała Augusta Hlonda
Tematy:
cyrkulacja powietrza
pył zawieszony PM10
atmosfera
Śląsk
atmospheric circulation
particulate matter (PM10)
atmosphere
Silesia
Opis:
Wyżyna Śląska jest najlepszym w Polsce przykładem obszaru poddanego całkowitej antropopresji. Rabunkowa gospodarka lat siedemdziesiątych szczególnie mocno znalazła swoje odbicie w poziomie emisji zanieczyszczeń, kiedy następował dynamiczny rozwój przemysłu i urbanizacji. Obecnie, kiedy mamy do czynienia ze znacznie ograniczoną emisją, niezmiernie ważne jest zbadanie wpływu cyrkulacji atmosferycznej na stan sanitarny powietrza. Realizowane zagadnienie jest przykładem tzw. meteorologii i klimatologii synoptycznej, w której dokonuje się oceny relacji pomiędzy elementami środowiska a warunkami cyrkulacyjnymi.
The Silesian Upland is the best example of an area under total anthropopressure in Poland. Wasteful exploitation of the 7O-ties was especially strongly reflected in the pollution emission levels accompanied by a dynamie development of urbanisation and industry. Presently, when the emission is much lower, investigation of the atmospheric circulation impact on the sanitary condition of the air is extremely important. The conducted studies are an example of the so called synoptic meteorology and climatology, in which a relationship between the elements of the environment and the circulation conditions are evaluated.
Źródło:
Problemy Ekologii; 2008, R. 12, nr 4, 4; 207-210
1427-3381
Pojawia się w:
Problemy Ekologii
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ emisji cząstek stałych z liniowych źródeł zanieczyszczenia na poziom stężenia pyłu zawieszonego PM10, PM2,5, PM1,0 w miejskim powietrzu atmosferycznym
The Impact of the Stable Particles Emission from Linear Pollution Sources on the Level of Concentration of the PM10, PM2,5, PM1,0 Dusts in Urban Atmospheric Air
Autorzy:
Dmochowska, A.
Dmochowski, D.
Kuskowska, K.
Wolna, J.
Powiązania:
https://bibliotekanauki.pl/articles/136687.pdf
Data publikacji:
2014
Wydawca:
Szkoła Główna Służby Pożarniczej
Tematy:
pyły
zanieczyszczenia powietrza
emisja liniowa zanieczyszczeń
dust
pollution of air
linear emission of pollution
Opis:
W artykule przedstawiono wyniki badań pyłu zawieszonego, pochodzącego z liniowych źródeł zanieczyszczeń emitowanych w bezpośrednim sąsiedztwie ogródków działkowych prawobrzeżnej Warszawy. Wyniki pomiarów pyłu zawieszonego i jego frakcji wykazały znaczne przekroczenia dopuszczalnych norm w punktach pomiarowych, położonych w najbliższych odległościach od Trasy Łazienkowskiej i alei Waszyngtona. Mogą one powodować nie tylko zagrożenie dla bezpieczeństwa ekologicznego w tym rejonie, ale także mogą wpływać na obniżenie bezpieczeństwa zdrowotnego użytkowników ogródków działkowych oraz okolicznych mieszkańców. Szczególnie niebezpieczna dla zdrowia jest drobna frakcja pyłu zawieszonego PM2,5, powodująca wzrost liczby zgonów wynikających z chorób serca, niedoczynności układu krążenia, niewydolności dróg oddechowych oraz raka płuc.
The paper presents the results of the research into the dust from the linear sources of pollution emitted close to the right-bank Warsaw allotments. The results of dust measurements and its fraction show that the legal limits of the concentration of dusts floating in the atmospheric air for the measurement points are exceeded. The points are located in the nearest distance from Trasa Łazienkowska and aleja Waszyngtona – two busy roads in the right-bank Warsaw. The results show that the dust and its fractions can pose the ecological safety hazards and can constitute a significant reduction of health safety of both allotments users and local residents. The fraction of the PM2.5 dust is especially dangerous for human health. It may cause an increase in the number of deaths resulting from heart disease.
Źródło:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej; 2014, 2, 50; 121-132
0239-5223
Pojawia się w:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Examination of Dust Concentration in the Interior Air of a Teaching Room
Autorzy:
Marczak, H.
Powiązania:
https://bibliotekanauki.pl/articles/123347.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
dust pollution
PM10
respirable fraction
suspended dust fractions
dust concentration in the interior air
Opis:
The issue of indoor air quality is becoming increasingly important. Ensuring optimal air parameters is important for the health of people who are particularly sensitive to impurities contained therein. Finding solutions that improve the quality of indoor air requires a prior detailed recognition of the problem of its pollution. The subject of the research is dust pollution in the air in a teaching laboratory room. The attention was focused on the characteristics of air pollution with the total dust fraction and suspended particulate fractions PM10 and PM2.5. The dust content was measured with a laser meter enabling indirect measurement. It consists in using the phenomenon of damping laser light scattered on the tested air sample at an angle of 90 degrees. As a result of the conducted research, factors influencing the increase of dust concentration in the indoor air were identified. These include the quality of the outdoor air and the source of dust emission in the room. In order to obtain more comprehensive data, it is necessary to continue the research with the possibility of extending the duration of the measurement tests and the test cycle.
Źródło:
Journal of Ecological Engineering; 2018, 19, 5; 99-106
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena zanieczyszczeń metali w pyłach PM10 i PM2,5 emitowanych z procesów przemysłowych sektora materiałów mineralnych
Evaluation of metal pollution in the dust PM10 i PM2,5 emitted from industrial processes of mineral materials sector
Autorzy:
Sładeczek, F.
Głodek-Bucyk, E.
Stec, K.
Powiązania:
https://bibliotekanauki.pl/articles/392164.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Ceramiki i Materiałów Budowlanych
Tematy:
przemysł mineralny
proces przemysłowy
zanieczyszczenie powietrza
pył zawieszony
PM
metal ciężki
stężenie
mineral industry
industrial process
air pollution
suspended particular matter
heavy metal
concentration
Opis:
W artykule omówiono wymagania prawne dotyczące koncentracji pyłu PM10 i PM2,5 oraz metali ciężkich w powietrzu i w emisjach. Przedstawiono stan badań w zakresie identyfikacji wymienionych zanieczyszczeń z instalacji przemysłowych oraz w otoczeniu. Zaprezentowano metodykę otrzymywania próbek pyłów PM10 i PM2,5 emitowanych z procesów przemysłowych oraz analiz metali zawartych w tych pyłach. Omówiono wstępne rezultaty analiz metali dla pyłów PM10 i PM2,5 emitowanych z instalacji cementowych i wapienniczych. Stwierdzono najwyższe zanieczyszczenia dla Zn, Pb oraz Mn, przy czym generalnie zanieczyszczenia z procesu wypalania klinkieru są wyższe niż z wypalania wapna.
The article discusses the legal requirements for particulate matter PM10 and PM2,5 and metal pollution in the air – in emissions and the environment. In addition, research state of pollution of particulate matter and metals from industrial processes and in the environment – in urban and rural areas was presented. The paper presents a methodology for obtaining samples of PM10 and PM2.5 emitted from industrial processes and the analysis of metals in these dusts. The paper shows the preliminary results of the analysis of metals for PM10 i PM2.5 emitted from cement and lime plants. It has been found the highest pollution for Zn, Pb and Mn, and in general greater contaminations from the clinker burning process than from the lime kiln.
Źródło:
Prace Instytutu Ceramiki i Materiałów Budowlanych; 2015, R. 8, nr 20, 20; 68-79
1899-3230
Pojawia się w:
Prace Instytutu Ceramiki i Materiałów Budowlanych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
How to effectively analyse the impact of air quality on society – review of modern measurement techniques and apparatus: particulates
Jak skutecznie analizować wpływ jakości powietrza na społeczeństwo – przegląd nowoczesnych technik i aparatury pomiarowej
Autorzy:
Mach, Tomasz
Bihałowicz, Jan Stefan
Powiązania:
https://bibliotekanauki.pl/articles/24202676.pdf
Data publikacji:
2022
Wydawca:
Szkoła Główna Służby Pożarniczej
Tematy:
particulate matter
PM10
PM2,5
XRF spectrometry
PM concentration
elemental composition
PM automatic measurement
pył zawieszony
PM2.5
spektrometria XRF
stężenie PM
skład pierwiastkowy
pomiar automatyczny PM
Opis:
The article discusses modern measurement techniques and equipment designed for air quality analysis. The problem of the quality of atmospheric and indoor air is strongly related to broadly understood public health. Modern measurement techniques allow faster and more effective assessments of the air quality condition in a given place. The paper discusses the structure, measurement method of solid pollutants and automatic measurement systems deploying the micro-oscillatory balance method, using the interaction of ionizing radiation with mattersuppression of beta radiation and gamma radiation spectrometry, optical methods based on light scattering on particulate matter and systems combining more than one method. Technical solutions introduced by manufacturers of measuring equipment, which allow more precise measurement of gaseous pollutants, were also discussed.
W artykule omówiono nowoczesne techniki pomiarowe i urządzenia do analizy jakości powietrza. Problem jakości powietrza atmosferycznego i wewnętrznego jest silnie związany z szeroko rozumianym zdrowiem publicznym. Nowoczesne techniki pomiarowe pozwalają na szybszą i skuteczniejszą ocenę stanu jakości powietrza w danym miejscu. W artykule omówiono budowę, metodę pomiaru zanieczyszczeń stałych oraz automatyczne systemy pomiarowe wykorzystujące metodę wagi mikrosiłownikowej, wykorzystujące oddziaływanie promieniowania jonizującego z materią – tłumienie promieniowania beta i spektrometrię promieniowania gamma, metody optyczne oparte na rozpraszaniu światła na poszczególnych cząstkach pyłu zawieszonego oraz systemy łączące więcej niż jedną metodę. Omówiono również rozwiązania techniczne wprowadzone przez producentów sprzętu pomiarowego, które pozwalają na bardziej precyzyjny pomiar zanieczyszczeń gazowych.
Źródło:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej; 2022, 84; 55--71
0239-5223
2720-0779
Pojawia się w:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Source apportionment of the PM10 fraction of particulate matter collected in Kraków, Poland
Autorzy:
Samek, L.
Powiązania:
https://bibliotekanauki.pl/articles/146888.pdf
Data publikacji:
2012
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
air pollution
energy dispersive X-ray fluorescence (EDXRF)
elemental concentration
particulate matter
statistical analyses
PCA - principal component factor analysis
MLRA - multilinear regression analysis
Opis:
Samples of PM10 fraction of air particulates were collected during the winter of 2010 at two different sites in the City of Kraków, Poland. One site was located nearby a steel mill (Nowa Huta district) and the second one was situated at a distance of 10 km from the first site (Krowodrza district). The measured mass concentrations of PM10 fraction were in the range of 33 to 358 μg/m3. They exceeded the permissible daily limit value of 50 μg/m3. The Voivodship Inspectorate for Environmental Protection in Kraków was in charge of collecting samples as well as determining mass concentrations. Assessment of elemental concentrations and statistical analyses were performed at the University of Science and Technology in Kraków. Mean concentrations of Ti, Cu, Br and Pb were almost the same at both sites, while those of K, Ca and Zn were two times higher at Nowa Huta than at Krowodrza. Cr, Mn and Fe mass concentrations were also higher at Nowa Huta site; the values were a factor of three higher for Cr and Mn and factor of four for Fe. Factor analysis (FA) and multilinear regression analysis (MLRA) were used to determine source contributions to ambient PM10. The measurements were based on PM10 composition data which included elemental concentrations. Local combustion, industry and other, not identified sources, such as secondary aerosols, were the factors that highly contributed to the pollution of PM10 during winter time. For the site at Nowa Huta 53.1% of pollution was attributable to combustion and traffic, 28.5% was due to industry and wood combustion, and 18.3% were not identified. For the Krowodrza site, industry and wood combustion contributed 46.1%, combustion and traffic 50.4% and other, not identified sources 3.5% of the total PM10. Examination of meteorological data suggested that the concentration of potassium was inversely proportional to ambient air temperature at both sites. A wood combustion was identified as possible source of potassium in PM10.
Źródło:
Nukleonika; 2012, 57, 4; 601-606
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stężenie pyłów zawieszonych PM10 w Polsce w 2015 roku– porównanie danych z serwisu CAMS programu Copernicus z danymi Głównego Inspektoratu Ochrony Środowiska
Concentration of particulate matters PM10 in Poland in 2015– the comparison of Copernicus Programme Services Data with the data published by the Chief Inspectorate for Environmental Protection
Autorzy:
Hys, Agnieszka
Dumańska, Joanna
Tworek, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/952656.pdf
Data publikacji:
2018
Wydawca:
Główny Urząd Miar
Tematy:
modele obliczeniowe
program Copernicus
pomiary stężenia pyłu zawieszonego
computational models
Copernicus Programme
particulate matter measurement
Opis:
W artykule przedstawiono porównanie wyników modeli obliczeniowych Programu Copernicus z danymi publikowanymi przez Główny Inspektorat Ochrony Środowiska, dotyczącymi stężeń pyłów zawieszonych PM10 dla terenu Polski w roku 2015, zarówno w okresie letnim, jak i zimowym. Opisano Program Copernicus oraz zaprezentowano podstawowe modele obliczeniowe, stosowane w analizie zanieczyszczeń powietrza atmosferycznego, które wykorzystują dane satelitarne dostarczane przez serwisy tego Programu. Przedstawiono teoretyczne zagadnienia dotyczące pyłów zawieszonych PM10 i ich udziału w zanieczyszczeniu powietrza atmosferycznego oraz zaprezentowano konkretne dane liczbowe dotyczące tematu opracowania.
The comparison of the Copernicus Programme Services data with the data published by the Chief Inspectorate for Environmental Protection on the concentration of particulate matters PM10 in Poland in 2015, both in summer and winter period, was presented. Program Copernicus was described and main calculation models for air pollution analysis based on Copernicus services satellite data were explained. The environmental aspects of PM10 and theirs impact on air pollution were presented as well as the figures related to the topic of this paper.
Źródło:
Metrologia i Probiernictwo : biuletyn Głównego Urzędu Miar; 2018, 1 (20); 12-19
2300-8806
Pojawia się w:
Metrologia i Probiernictwo : biuletyn Głównego Urzędu Miar
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-24 z 24

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies