Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Nowak, R." wg kryterium: Wszystkie pola


Tytuł:
Fatty acids composition in fruits of wild rose species
Autorzy:
Nowak, R
Powiązania:
https://bibliotekanauki.pl/articles/57682.pdf
Data publikacji:
2005
Wydawca:
Polskie Towarzystwo Botaniczne
Tematy:
Rosa rugosa
Rosaceae
wild rose
Rosa rubiginosa
rose
fatty acid
rose species
oil content
composition
fruit
Rosa dumalis
Opis:
The oil content and fatty acids profile of a number of Polish wild species of rose fruits were examined by GC. The total fatty acid contents ranged from 6.5% to 12.9% of dry mass in fruits. The composition of oils was similar in the investigated species. 17 components were identified. An average composition was estimated as follows: linoleic acid (44.4-55.7%), a-linolenic acid (18.6-31.4%), oleic acid (13.5-20.3%), palmitic acid (2.3-3.3%), stearic acid (1-2.5%), octadecenoic acid (0.38-0.72%), eicosenoic acid (0.3-0.7%), eicosadienoic acid (0-0.16%), erucic acid (0.03-0.17%) and minor fatty acids. The results indicate that rose fruits are a rich source of unsaturated fatty acids, especially in R. rubiginosa, R. rugosa and R. dumalis. There were statistically significant (p<0.05) differences in fatty acid compositions of some species. Fatty acids were suggested to have a potential chemotaxonomic value in this genus.
Źródło:
Acta Societatis Botanicorum Poloniae; 2005, 74, 3
0001-6977
2083-9480
Pojawia się w:
Acta Societatis Botanicorum Poloniae
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wybrane algorytmy sterowania silnikami z magnesami trwałymi
Selected control algorithms of permanent magnet motors
Autorzy:
Nowak, R.
Powiązania:
https://bibliotekanauki.pl/articles/304870.pdf
Data publikacji:
2018
Wydawca:
Wydawnictwo Druk-Art
Tematy:
silniki synchroniczne z magnesami trwałymi PMSM
silniki bezszczotkowe prądu stałego BLDC
sterowanie wektorowe
permanent magnet synchronous motors PMSM
brushless direct-current motors BLDC
vector control
Opis:
W artykule przedstawiono wybrane algorytmy sterowania silnikami z magnesami trwałymi: silnikami bezszczotkowymi prądu stałego BLDC oraz silnikami synchronicznymi z magnesami trwałymi PMSM. Maszyny takie, pomimo zbliżonej konstrukcji mechanicznej, diametralnie różnią się pod względem opisu modelu matematycznego, a co za tym idzie – sposób ich sterowania jest inny. W publikacji ukazano analogię opisywanych metod do strategii sterowania komutatorowego silnika prądu stałego. Zaprezentowano wyniki badań symulacyjnych opisywanych algorytmów. Omówiono kwestię dwustrefowego sterowania prędkością kątową wału. Podano wytyczne dla konstruktorów układów sterowania ułatwiające podejmowanie decyzji dotyczących wyboru danego rozwiązania, jak i jego późniejszej implementacji. Omówiono wybrane aspekty konstrukcji przekształtników energoelektronicznych wykorzystywanych do sterowania silników z magnesami trwałymi.
The paper presents the selected control algorithms of permanent magnet motors: brushless direct-current motors BLDC and permanent magnet synchronous motors PMSM. Such machines despite their similar mechanical structure have an entirely different mathematical model and therefore their control algorithms are different. The publication shows the analogy between the described methods and the control strategy of a brushed DC motor. The results of the simulation tests of the described algorithms were presented. The issue of two-zone control angular velocity of the shaft is discussed. The article provides guidance for designers of control systems to facilitate decision-making regarding the selection of the solution and its subsequent implementation. It discusses some selected aspects of the construction of power converters used to control permanent magnet motors.
Źródło:
Napędy i Sterowanie; 2018, 20, 6; 86-90
1507-7764
Pojawia się w:
Napędy i Sterowanie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wybrane algorytmy sterowania silnikami z magnesami trwałymi
Selected control algorithms of permanent magnet motors
Autorzy:
Nowak, R.
Powiązania:
https://bibliotekanauki.pl/articles/1199656.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
silniki synchroniczne z magnesami trwałymi PMSM
silniki bezszczotkowe prądu stałego BLDC
sterowanie wektorowe
permanent magnet synchronous motors PMSM
brushless direct-current motors BLDC
vector control
Opis:
The paper presents the selected control algorithms of permanent magnet motors: brushless directcurrent motors BLDC and permanent magnet synchronous motors PMSM. Such machines despite their similar mechanical structure have an entirely different mathematical model and therefore their control algorithms are different. The publication shows the analogy between the described methods and the control strategy of a brushed DC motor. The results of the simulation tests of the described algorithms were presented. The issue of two-zone control angular velocity of the shaft is discussed. The article provides guidance for designers of control systems to facilitate decision-making regarding the selection of the solution and its subsequent implementation. It discusses some selected aspects of the construction of power converters used to control permanent magnet motors.
W artykule przedstawiono wybrane algorytmy sterowania silnikami z magnesami trwałymi: silnikami bezszczotkowymi prądu stałego BLDC oraz silnikami synchronicznymi z magnesami trwałymi PMSM. Maszyny takie pomimo zbliżonej konstrukcji mechanicznej diametralnie różnią się pod względem opisu modelu matematycznego, co za tym idzie sposób ich sterowania jest inny. W publikacji ukazano analogię opisywanych metod do strategii sterowania komutatorowego silnika prądu stałego. Zaprezentowano wyniki badań symulacyjnych opisywanych algorytmów. Omówiono kwestię dwustrefowego sterowania prędkością kątową wału. Podano wytyczne dla konstruktorów układów sterowania ułatwiające podejmowanie decyzji dotyczących wyboru danego rozwiązania, jak i jego późniejszej implementacji. Omówiono wybrane aspekty konstrukcji przekształtników energoelektronicznych wykorzystywanych do sterowania silników z magnesami trwałymi.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2017, 1, 113; 123-128
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ wybranych składników uzdatnianej wody na skuteczność jej odmanganiania w obecności mas aktywnych
Influence of the selected components of treated water on the effectiveness of manganese removal in the presence of the active masses
Autorzy:
Nowak, R.
Powiązania:
https://bibliotekanauki.pl/articles/1818751.pdf
Data publikacji:
2013
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
masy aktywne
wpływ wybranych składników
uzdatnianie wody
impact of selected components
water treatment
Opis:
This paper presents the results of research the process of manganese removal from water involving five selected active masses, different in physical and chemical structure. Attempt was made to determine the effect of selected factors (humic acids and iron concentration, pH level) on the efficiency of manganese removal from water in the presence of the active masses. The studies clearly showed that the efficiency of the process of manganese removal from water in the presence of active masses depends inter alia on quality parameters of the treated water. Depending on the presence of other constituents in water, removal of manganese from water may be more or less effective. The results showed that humic acids have a negative impact on the removal of manganese from water in the presence of each of the examined active masses. A very important factor in the process of manganese removal from water was its pH. In the water containing no humic acids removal efficiency of manganese in the presence of examined active masses increased with increasing pH. In particular, manganese removal of water characterized by typical groundwater pH (pH 7) proceeded most efficiently in the presence of masses G-1 and Purolite MZ-10. On the opposite other examined active masses (Birm, Hydrocleanit, Defeman) showed a low effectiveness at neutral pH. The biggest impact of pH of water on the effectiveness of manganese removal was noticed for Birm mass. Results of this part of of the showed that the negative effect of pH on the effectiveness of manganese removal from water containing humic acids (recorded for the masses Purolite MZ-10, G-1 and Birm) may have resulted from the chemical structure of humic acids and their solubility, which increased with increasing pH of water. Effect of the presence of iron in the water on the effectiveness of removal of manganese is not so clear. The negative impact of the presence of iron occurs when in the treated water it is present in dissolved form (divalent ions). Then oxidation of manganese ions takes place only afer the oxidation of iron ions. Presented results of studies the process of manganese removal in the presence of active masses clearly indicate the need of continuation and verification under dynamic conditions.
Źródło:
Rocznik Ochrona Środowiska; 2013, Tom 15, cz. 1; 714-728
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ prędkości filtracji na usuwanie manganu i żelaza z wody na wybranych złożach filtracyjnych
The effect of flow rate on the manganese and iron removal from water
Autorzy:
Nowak, R.
Powiązania:
https://bibliotekanauki.pl/articles/908541.pdf
Data publikacji:
2013
Wydawca:
Fundacja Ekonomistów Środowiska i Zasobów Naturalnych
Tematy:
filtration
manganese and iron removal from water
active masses
water flow rate
filtracja
usuwanie manganu i żelaza z wody
masy aktywne
przepływ wody
Opis:
W ramach niniejszej pracy wykonano badania zmierzające do określenia odżelaziania z udziałem wybranych mas aktywnych. Dodatkowo, w celu dokładniejszej interpretacji uzyskanych wyników badań procesu filtracji, przeprowadzono analizę sitową zastosowanych mas oraz określono porowatość złóż filtracyjnych. Do badań przyjęto cztery dostępne na rynku masy aktywne, czyli Birm, G-1, Purolite MZ-10 oraz Defeman. W skład Birmu wchodzi ditlenek manganu, amorficzna i krystaliczna krzemionka oraz składniki wiążące. Purolite MZ-10 jest naturalnym zeolitem, składającym się głównie ze związków SiO2 i Al2O3. Masy G-1 oraz Defeman to materiały naturalne, składające się (podobnie jak Birm) między innymi z ditlenku manganu. Badania dynamiczne były prowadzone po okresie wpracowania się złóż, zaś w przypadku masy Purolite MZ-10 (zgodnie z zaleceniem producenta) złoże było poddawane regeneracji roztworem KMnO.
In the paper the results of research on manganese and iron removal process are presented. The study was carried out on Laboratory-scale columns experiments filters with variable water flow rate: 5, 7.5, 10, 12, 15 and 18 m/h and four types of materials were studied. The results of the research allowed comparing and estimating the effect of various water flow rate for effectiveness of tested filter materials. Among activated filtrating masses G-1, Purolite MZ-10 and Bir showed satisfying effects. However, activated mass Defeman shows worsen effectiveness in manganese and iron removal with higher filtrating speed. Research result shows, that selecting particular filter bed and setting up the parameters of filtering process should be done basing on the qualitative and quantitive of treated water and preliminary research done in laboratory scale or semi-technical scale.
Źródło:
Ekonomia i Środowisko; 2013, 2; 160-168
0867-8898
Pojawia się w:
Ekonomia i Środowisko
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The impact of the structure of the active mass to changes in selected parameters of water
Autorzy:
Nowak, R.
Powiązania:
https://bibliotekanauki.pl/articles/123404.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
chemical structure
active mass
water
Opis:
The paper presents the results from studies upon the influence of chemical structure of filtration masses used for the treatment of groundwater on the values of selected physicochemical parameters of water. The pH value of treated water and the redox potential are important in process the oxidation of iron and manganese compounds. These values may change as a result of water contact with filter materials. The value of zeta potential of filtration masses characterizing the surface charge of particles and their affinity to counter-ions, is also important. The study tested masses of different chemical structure, i.e. manganese ores and de-acidifying masses. Experiments were carried out at two different pH values of the model water. The results showed that the filtration masses affected the water quality and water treatment processes, and the type and magnitude of changes in physicochemical parameters are closely related to, among others, the chemical structure of the filter bed.
Źródło:
Journal of Ecological Engineering; 2016, 17, 5; 155-162
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stan gospodarki ściekowej na terenach wiejskich na przykładzie powiatu koszalińskiego
Wastewater management status in rural areas presented on the example of Koszalin County
Autorzy:
Nowak, R.
Powiązania:
https://bibliotekanauki.pl/articles/1215645.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Przemysłu Chemicznego. Zakład Wydawniczy CHEMPRESS-SITPChem
Tematy:
gospodarka ściekowa
infrastruktura techniczna
powiat koszaliński
wastewater management
technical infrastructure
Koszalin District
Opis:
Artykuł przedstawia rozwój oraz stan sieci kanalizacyjnej na terenie ośmiu gmin wiejskich powiatu koszalińskiego w latach 004–2013. Podstawą analizy były dane z roczników statystycznych GUS – Ochrona Środowiska oraz Banku Danych Lokalnych, a także z raportów z wdrażania Krajowego Programu Oczyszczania Ścieków Komunalnych. Przeprowadzona analiza wykazała niejednorodny stopień uzbrojenia gmin powiatu koszalińskiego w sieć kanalizacyjną i oczyszczalnie ścieków, różny przyrost sieci kanalizacyjnej w czasie, a także różnice w udziale ludności powiatu, korzystającej z sieci i oczyszczalni ścieków. W ostatnich latach widoczny jest wyraźny przyrost ludności powiatu, korzystających z oczyszczalni ścieków oraz z sieci kanalizacyjnej. Obserwuje się przy tym tendencje do wzrostu ilości ścieków, oczyszczanych w wysokosprawnych technologiach.
The article presents the development and condition of the sewage system in eight rural communities in the Koszalin County in the years 2004 – 2013. The basis for the analysis was data from Statistical Yearbook from Central Statistical Office – Environment Protection and Local Data Bank, and from National Programme for Municipal Waste Water Treatment implementation reports. The study showed a heterogeneous state of development of the sewage network and wastewater treatment plant (WWTP), different growth of network, as well as variability in the share of the county population using the sewage network and WWTP. In last years the increase of Mount of people who use the WWTP and sewage network is clearly seen. Moreover, the tendency for increasing amount of sewage treated in high performance technologies is observed.
Źródło:
Chemik; 2014, 68, 10; 856-861
0009-2886
Pojawia się w:
Chemik
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mechanizmy uszkodzeń ceglanych nadproży łukowych
Mechanisms of brick arched lintels damage
Autorzy:
Orłowicz, R.
Nowak, R.
Powiązania:
https://bibliotekanauki.pl/articles/217733.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Konserwatorów Zabytków
Tematy:
uszkodzenie
nadproże łukowe
arched lintel
damage
Opis:
Niniejszy artykuł zawiera aktualną wiedzę o budowie łukowych nadproży. Zostało udowodnione, że dobrze znana teoria różni się od faktycznych prac budowlanych i że sprawdza się tylko w sporadycznych przypadkach. Dokonano analizy danych typowych typów morfologicznych pęknięć i rys. Wydział Inżynierii lądowej i Architektury Zachodu pomorskiej Politechniki rozpoczął badanie nad opisanym zagadnieniem.
The following article contains the current knowledge about construction of arched lintels. It had been proved that well - known theory differs from actual construction work and it proves correct only in occasional cases. There was made statistic analysis of typical morphological types of cracks and scratches. Department of Civil Engineering and Architecture in The West Pomeranian University of Technology has started research on the described issue.
Źródło:
Wiadomości Konserwatorskie; 2009, 26; 253-259
0860-2395
2544-8870
Pojawia się w:
Wiadomości Konserwatorskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania efektywności usuwania azotu amonowego na wybranych materiałach sorbcyjnych
Study on ammonia nitrogen removal efficiency on selected sorbents
Autorzy:
Piaskowski, K.
Nowak, R.
Powiązania:
https://bibliotekanauki.pl/articles/1819352.pdf
Data publikacji:
2012
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
azot amonowy
materiał sorbcyjny
Opis:
In this paper the authors present the impact study on the electrokinetic potential of ammonium nitrogen removal capabilities using various sorption materials. The study included an analysis of the electrokinetic potential zeta of the selected sorbents and their suitability to determine the removal efficiency of ammonium ions from the model solution and a liquid sludge from the sludge digestion process. Used materials were both natural and modified in the form of dust: activated carbon, natural zeolite, bentonite, sepiolite and ferric sludge from water treatment. Tested materials had a negative electrokinetic potential. The lowest potential of activated carbon had a value of zeta = -20.4 mV and the highest value zeta = -12.1 mV obtained for sepiolite. The results showed a clear dependence of ammonia nitrogen removal on the value of the electrokinetic potential. Sorbents with the most negative zeta potential values had a highest removal efficiency of ammonium ions (carbon, zeolite). The maximum value of the individual removal of ammonium ions was 10 mg N-NH4/g of activated carbon, which is characterized by the most negative value of the electrokinetic potential zeta. The results from this study suggest that, the usefulness of knowledge of the electrokinetic potential, as one of the key parameters of evaluating the physicochemical properties of sorbents.
Źródło:
Rocznik Ochrona Środowiska; 2012, Tom 14; 563-571
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Architektura a statyka ceglanych nadproży łukowych
Architecture and statics of bricks curve lintel
Autorzy:
Pawłowski, W.
Nowak, R.
Powiązania:
https://bibliotekanauki.pl/articles/369749.pdf
Data publikacji:
2009
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
ceglane nadproża łukowe
rodzaje łuków w architekturze
bricks curve lintel
kind of arches in architecture
Opis:
Zwieńczenia łukowe stanowią istotny element zarówno konstrukcyjny jak również architektoniczny w całej formie przestrzennej obiektów w których występowały, jednakże należy stwierdzić iż wiedza o pracy łuków powstała dopiero w XVIII wieku, a co za tym idzie w pełni świadomego ich stosowania przyczyniło się do prawidłowego ich wykorzystania w budownictwie na przestrzeni minionych wieków.
Bricks curve LINTEL are important architectural and cnstructional elements in whole spatial form of object, however, it belongs to ascertain that knowledge emerge about work of arch in XVIII century. It has effected correction of safety building structure.
Źródło:
Przestrzeń i Forma; 2009, 12; 115-122
1895-3247
2391-7725
Pojawia się w:
Przestrzeń i Forma
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena wybranych właściwości modyfikowanych kompozytów PVC stosowanych na spody obuwia ochronnego
Evaluation of some properties of modified composites used PVC soles of safety footwear
Autorzy:
Nowak, R.
Żurowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/254093.pdf
Data publikacji:
2015
Wydawca:
Instytut Naukowo-Wydawniczy TTS
Tematy:
PVC
obuwie ochronne
safety footwear
Opis:
W pracy przedstawiono wyniki badań właściwości fizykomechanicznych i użytkowych kompozytów PVC modyfikowanych kauczukami, stosowanych na spody obuwia ochronnego. Do badań zastosowano polskie kauczuki typu KPN-124 i KPN-140 oraz dla porównania z importu firmy Goodyear typu Chemigum: P-8B-A, P-83 i PFC. Badania zostały wykonane w Spółce "Pol-Plast" w Pionkach. Stwierdzono, że dodatek Chemigumów wpływa korzystnie na właściwości kompozytów stosowanych na spody obuwia ochronnego.
The paper presents the results of physical and mechanical properties and performance rubbers modified PVC composites used on the soles of safety footwear. The study used the type rubbers Polish KPN-124 and KPN-140 and for comparison with imports Goodyear Chemigum type: P-8B-A, P-83 and PFC. The study was carried out in the Company 'PolPlast "in Pionki. It was found that the addition of Chemigumów positive effect on the properties of composites used on the soles of safety footwear.
Źródło:
TTS Technika Transportu Szynowego; 2015, 12; 1127-1131, CD
1232-3829
2543-5728
Pojawia się w:
TTS Technika Transportu Szynowego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza nośności ceglanych nadproży klinowych
Analysis of load bearing capacity for brick-laid wedge-type lintels
Autorzy:
Nowak, R.
Orłowicz, R.
Powiązania:
https://bibliotekanauki.pl/articles/161243.pdf
Data publikacji:
2017
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
konstrukcja ceglana
nadproże klinowe
nośność
analiza nośności
modelowanie
badanie doświadczalne
brick structure
wedge lintel
load bearing capacity
capacity analysis
modelling
experimental investigation
Opis:
Przytoczono zarys typowych uszkodzeń ceglanych płaskich nadproży klinowych, jakie występują w budynkach murowych. Podjęto próbę analizy nośności przedmiotowych konstrukcji na podstawie obserwacji własnych. Omówiono wyniki badań doświadczalnych.
The article outlines the typical damage applicable in case of the flat brick-laid wedged lintels, present in case of brick buildings. An attempt has been made to analyze the load-bearing capacity for the structures covered within the text, on the basis of own observations. Results of the experimental research have also been thoroughly discussed.
Źródło:
Przegląd Budowlany; 2017, 88, 2; 21-23
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nośność ceglanych nadproży łukowych o kształtach półkolistych
Carrying capacity of arched brick lintels of semi-circular shape
Autorzy:
Nowak, R.
Orłowicz, R.
Powiązania:
https://bibliotekanauki.pl/articles/161465.pdf
Data publikacji:
2016
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
nadproże łukowe
kształt półkolisty
konstrukcja ceglana
nośność
badanie modelowe
arched lintel
semi-circular shape
brick structure
load bearing capacity
model testing
Opis:
W artykule omówiono najważniejsze wyniki z badań prowadzonych na nadprożach murowanych półkolistych. Wykazano wzrost nośności dla nadproży z warstwami muru ponad łukiem. Zaprezentowano otrzymane wyniki z symulacji numerycznych oraz badań doświadczalnych.
The article discusses the most important research results referring to brick laid lintels of semi-circular shape. Increased carrying capacity has been proven for lintels with bricklaid layers above the arch. Moreover, the obtained numerical simulation and experimental research results are also presented within the article content.
Źródło:
Przegląd Budowlany; 2016, R. 87, nr 11, 11; 53-55
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmodernizowany iskrobezpieczny zespół sterowania ZKL-2 o strukturze modułowej
Modernized intrinsically safe control unit ZKL-2 of a module structure
Autorzy:
Berkowicz, M.
Nowak, R.
Powiązania:
https://bibliotekanauki.pl/articles/185949.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technik Innowacyjnych EMAG
Tematy:
iskrobezpieczny zespół sterowania ZKL-2
intrinsically safe control unit ZKL-2
Opis:
W artykule przedstawiono budowę i własności funkcjonalne iskrobezpiecznego zespołu sterowania ZKL-2. Zespół sterowania ZKL-2 jest zmodernizowaną wersją ze-społu sterowania ZKL-1, eksploatowanego w kopalnianych układach sterowania kołowrotów i kolejek o napędzie elektrycznym lub hydraulicznym oraz kruszarek i pomp w pomieszczeniach "a", "b" i "c" niebezpieczeństwa wybuchu metanu. W pracach modernizacyjnych uwzględnione zostały aktualne normy i przepisy oraz dotychczasowe doświadczenia eksploatacyjne, a wprowadzenie budowy modułowej umożliwiło łatwiejszą adaptację do aktualnych potrzeb użytkowników, zwiększając równocześnie możliwości jego zastosowań.
A structure and functional properties of an intrinsically safe control unit ZKL-2 has been presented in the paper. The control unit ZKL-2 is an upgraded version of the control unit ZKL-1 which has been used in the mining control systems of winches and trains with electric or hydraulic drives as well as crushers and pumps operated in methane explosive "a", "b" and "c" classified hazardous areas. The recent standards and regulations as well as operating experiences had been taken into consideration when the upgrading was made. The module structure allowed an easier adaptation for current needs of users and increased in potential of applications.
Źródło:
Mechanizacja i Automatyzacja Górnictwa; 2009, R. 47, nr 3, 3; 39-46
0208-7448
Pojawia się w:
Mechanizacja i Automatyzacja Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ położenia i kształtu elementu piezoelektrycznego na pozyskiwaną energię elektryczną
Influence of the piezoelectric element position and shape on energy harvesting
Autorzy:
Nowak, R.
Pietrzakowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/404174.pdf
Data publikacji:
2012
Wydawca:
Polskie Towarzystwo Symulacji Komputerowej
Tematy:
piezoelektryk
belka
MES
pozyskiwanie energii elektrycznej
piezoelectric
beam
FEM
energy harvesting
Opis:
W niniejszej pracy skupiono się na zbadaniu wpływu kształtu i położenia generatora piezoelektrycznego na pozyskiwane napięcie. Rozważono układ mechaniczny w postaci belki wysięgnikowej z przyklejonym przetwornikiem piezoelektrycznym, spolaryzowanym poprzecznie. Zastosowano generator w kształcie prostokątnym i trójkątnym. Na podstawie obliczeń analitycznych dokonano wyboru możliwie efektywnego generatora. Wyznaczono charakterystyki amplitudowo-częstotliwościowe wytwarzanego napięcia w przypadku drgań belki w zakresie pierwszej i drugiej częstotliwości rezonansowej. Do obliczeń porównawczych, przeprowadzonych metodą elementów skończonych (MES), wybrano generator prostokątny, rozłożony na dwóch trzecich długości powierzchni belki. Wykazano zadowalającą zgodność wyników uzyskanych metodą analityczną i MES.
This study focuses on examining the influence of the shape and position of the piezoelectric generator on the harvested voltage. The considered mechanical system is the cantilever beam with the glued transversely polarized piezoelectric transducer. Both rectangular and triangular generators were used. Using analytical calculations, the generator's shape was selected as efficiently as possible. Amplitude-frequency characteristics were determined in the first and second resonant frequency range. The rectangular generator covering two-thirds of the upper surface of the beam was selected for comparative calculations. The results of both methods were compared with acceptable agreement.
Źródło:
Symulacja w Badaniach i Rozwoju; 2012, 3, 3; 131-140
2081-6154
Pojawia się w:
Symulacja w Badaniach i Rozwoju
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ lunet na stan naprężeń sklepień kolebkowych historycznych budynków
The influence of lunets on the state of stresses of barrel vaults of historical buildings
Autorzy:
Orłowicz, R.
Nowak, R.
Powiązania:
https://bibliotekanauki.pl/articles/162787.pdf
Data publikacji:
2018
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
budynek zabytkowy
sklepienie murowane
sklepienie kolebkowe
luneta
rozkład naprężeń
historic building
masonry vault
barrel vault
lunette
stress distribution
Opis:
Ceglane sklepienia w obiektach historycznych po wieloletniej eksploatacji często budzą obawy odnośnie ich nośności i możliwości dalszego bezpiecznego użytkowania. Dotyczy to zwłaszcza sklepień w remontowanych obiektach zabytkowych lub obiektach poddanych modernizacji ze względu na zmianę sposobu użytkowania. Uszkodzenie lub stan awaryjny sklepień występuje najczęściej z uwagi na poziome przemieszczenia wezgłowi sklepień, co z kolei powodowane jest przez niezrównoważone siły rozporu lub nierównomierne pionowe osiadanie ścian czy filarów nośnych.
After many years of exploitation, brick vaults in historical buildings often raise concerns about their loadbearing capacity and the possibility of further safe use of those facilities. This applies especially to vaults in renovated historical buildings or facilities which undergo modernization due to a change in the way of exploitation. The damage or emergency condition of the vaults occurs most often due to horizontal displacement of the vault abutments, which in turn is caused by unbalanced expansion forces or uneven vertical settlement of walls or load-bearing pillars.
Źródło:
Przegląd Budowlany; 2018, 89, 3; 35-37
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania symulacyjne piezoelektrycznego dwubelkowego układu pozyskiwania energii elektrycznej
Simulation investigations of the double beam piezoelectric energy harvester
Autorzy:
Nowak, R.
Pietrzakowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/404101.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Symulacji Komputerowej
Tematy:
generator piezoelektryczny
MES
metoda elementów skończonych
pozyskiwanie energii elektrycznej
układ dwubelkowy
piezoelectric generator
FEM
finite element method
energy harvesting
double cantilever beam
Opis:
Zaproponowany układ dwubelkowy składa się z generatora z warstwami piezoelektrycznymi i wzmacniacza drgań. Wymuszenie kinematyczne zrealizowano jako harmoniczny poprzeczny ruch podpory. W pracy skupiono się na wpływie parametrów geometrycznych i materiałowych wzmacniacza na efektywność zamiany energii mechanicznej w energię elektryczną. Wyniki otrzymane metodą analityczną i metodą elementów skończonych przedstawiono w postaci charakterystyk amplitudowo-częstotliwościowych generowanego napięcia. Porównano wybrane maksymalne wartości amplitudy napięcia i częstości drgań własnych, zestawiając je w tabelach. Na podstawie oszacowanych błędów względnych stwierdzono poprawność zastosowanego modelu MES.
In this paper the double beam system, which consists of generator (with piezoelectric layers) and resonator, was presented. Excitation was realized by the transverse harmonic movement of the support. The influence of geometrical and material properties of the resonator on the efficiency of conversion from mechanical energy into electrical energy were investigated. Results obtained by the analytical and the finite element method were shown as amplitude-frequency characteristics of the generated voltage. Comparison of the maximum voltage amplitude and the natural frequencies was summarized in the tables. On the basis of relative errors the correctness of the FEM model was confirmed.
Źródło:
Symulacja w Badaniach i Rozwoju; 2015, 6, 3; 185-192
2081-6154
Pojawia się w:
Symulacja w Badaniach i Rozwoju
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Założenia integracji baz danych ewidencji gruntów i budynków oraz rejestru planów miejscowych dla gminy
The assumptions of the integration of cadastral and planning databases and the communes register of area development plans
Autorzy:
Dzikowska, T.
Nowak, R.
Powiązania:
https://bibliotekanauki.pl/articles/131284.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
baza danych
ewidencja gruntów
plan miejscowy
rejestr planów
wypis z planu
database
cadastre
area development plan
register of plans
extract of plan
Opis:
Aktualny rozwój systemów informacji przestrzennej stwarza warunki do wykorzystania tych systemów i integrowania z innymi bazami danych, dla których jednostką bazową mogłaby być podstawowa informacja o działkach ewidencyjnych. Bazy zintegrowane powinny posiadać ten sam albo podobny poziom szczegółowości i skali opracowania. Wydzieloną bazą informacji o jednostkach przestrzennych stanowią miejscowe plany zagospodarowania przestrzennego wraz z rejestrami tych planów dla każdej gminy. Mimo wzajemnej niezależności tych baz, w procesie inwestycyjnym następuje konieczność ich scalenia, w celu jednoznacznego zdefiniowania przedmiotu, podmiotu i formalnych zapisów w planie miejscowym. Niniejsza praca podzielona została na następujące części: Część 1 – teoretyczna, w której dokonano analizy określenia powiązań relacyjnych pomiędzy atrybutami poszczególnych elementów ewidencji gruntów i budynków oraz planów miejscowych. Część 2 – obejmująca zagadnienia związane z dostępem online do informacji oraz przykładowe zastosowania. Część 3 – analiza korzyści i usprawnień w pracach urzędów lokalnych w związku z dostosowaniem techniki rysunku planu miejscowego do wymagań opracowań GIS.
Present land information system (LIS) development creates new possibilities of using those systems and integrating them with other databases, where a parcel is the basic information record. The integrated databases should have the same or similar detailing level and scale of map. A separate database is the collection of area development plans for each commune. Although those databases are mutually independent, they need to become integrated in the course of the investment process, in order to explicitly define the subject, the object, and formal records in the local area development plan. This papers contains following sections: Section 1: Theoretical analysis, describing relations between attributes of the cadastre and area development plans. Section 2: Online access to cadastral and planning information, as well as exemplary applications. Section 3: Benefits and improvements in the work of local government agencies resulting from the adjustment of area development plan drawing technology to GIS requirements.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2009, 19; 81-89
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evolutionary Algorithm that Designs the DNA Synthesis Procedure
Autorzy:
Michalak, M.
Nowak, R.
Powiązania:
https://bibliotekanauki.pl/articles/308431.pdf
Data publikacji:
2011
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
bioinformatics
gene synthesis
optimum searching
Opis:
Chemical synthesis of nucleotide chains is very erroneous for long sequences. Often a gene is constructed from short fragments joined with the use of complementary helper chains. The number of possible potential solutions for a long gene synthesis is very large, therefore a fast automated search is required. In the presented approach a modified method of long DNA construction is proposed. A computer program that searches for an optimal solution in the space of potential synthesis methods has been developed. This software uses an evolutionary algorithm for global optimization and a hillclimbing algorithm for local optimization. The long DNA construction method was tested on random sequences. The results are very promising. The next step is to perform experiments in a biotechnological wet laboratory involving DNA strand synthesis using the method designed by the presented software.
Źródło:
Journal of Telecommunications and Information Technology; 2011, 4; 50-54
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dopant-Based Charge Sensing Utilizing P-I-N Nanojunction
Autorzy:
Nowak, R.
Jabłoński, R.
Powiązania:
https://bibliotekanauki.pl/articles/220915.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
nanosensor
silicon
p-i-n junction
dopant
Kelvin Probe Force Microscope
Opis:
We studied lateral silicon p-i-n junctions, doped with phosphorus and boron, regarding charge sensing feasibility. In order to examine the detection capabilities and underlying mechanism, we used in a complementary way two measurement techniques. First, we employed a semiconductor parameter analyzer to measure I−V characteristics at a low temperature, for reverse and forward bias conditions. In both regimes, we systematically detected Random Telegraph Signal. Secondly, using a Low Temperature Kelvin Probe Force Microscope, we measured surface electronic potentials. Both p-i-n junction interfaces, p-i and i-n, were observed as regions of a dynamic behaviour, with characteristic time-dependent electronic potential fluctuations. Those fluctuations are due to single charge capture/emission events. We found analytically that the obtained data could be explained by a model of two-dimensional p-n junction and phosphorus-boron interaction at the edge of depletion region. The results of complementary measurements and analysis presented in this research, supported also by the previous reports, provide fundamental insight into the charge sensing mechanism utilizing emergence of individual dopants.
Źródło:
Metrology and Measurement Systems; 2017, 24, 2; 391-399
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania ceglanych sklepień balkonów
Studies of brick vaults of balkonies
Autorzy:
Nowak, R.
Orłowicz, R.
Powiązania:
https://bibliotekanauki.pl/articles/162138.pdf
Data publikacji:
2018
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
balkon
sklepienie ceglane
badanie
naprawa
metoda naprawy
balcony
brick vault
testing
repair method
Opis:
Balkon stanowi istotny element konstrukcyjny budynku, pozostający pod wpływem bezpośrednich oddziaływań czynników atmosferycznych. Cykliczne zmiany temperatury i wilgotności, deszcze, obciążenia nawisem śniegowym i bezpośrednie opady śniegu, a także obciążenia składowanymi często na balkonie materiałami określają trudne warunki jego eksploatacji, sprzyjające uszkodzeniom zwłaszcza płyty balkonowej. Podstawowa przyczyna jej uszkodzenia jest związana z przedostawaniem się wody do wnętrza. Ocena stanu technicznego balkonu nie powinna być zatem traktowana drugorzędnie, a jej przeprowadzenie wymaga usunięcia fragmentu warstwy wierzchniej płyty, określenia stanu izolacji wodochronnej i elementów konstrukcyjnych płyty.
The balcony constitutes an important structural element of the building, which is influenced by the direct impact of atmospheric factors. Cyclical changes in temperature and humidity, rains, snow overhang loads and direct snowfall, as well as loads with materials often stored on the balcony determine the difficult conditions of its exploitation, which contribute to damage especially to the balcony slab. The main cause of its damage is related to the water entering the interior. The assessment of the technical condition of the balcony should therefore not be treated as secondary and its implementation requires removal of a fragment of the surface layer of the balcony, determination of the waterproofing layer and structural elements of the slab.
Źródło:
Przegląd Budowlany; 2018, 89, 5; 34-35
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of Phase Transformations on Incipient Plasticity of Si-Nanospheres
Autorzy:
Chrobak, D.
Nowak, R.
Powiązania:
https://bibliotekanauki.pl/articles/1033040.pdf
Data publikacji:
2017-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
62.20.-x
62.50.-p
64.70.kg
Opis:
Our finding of the current spike effect highlighted for the first time in 2009 offers an enhanced understanding of the link between nanoscale mechanical deformation and electrical behavior, and ultimately suggests key advances in unique phase-change applications in future electronics. Certainly, crystal imperfections affect the properties of the nanoparticles themselves, e.g., their biocompatibility and biodegradability. The potential role of dislocations having a profound impact on the use of Si nanoparticles was largely overlooked, since plastic deformation of bulk Si is dominated by amorphization and phase transformations. Here we show an effect of bulk → nanoparticle transition (deconfinement) on incipient plasticity of Si-nanovolume. Our results provide a fresh insight into the dilemma concerning dislocation or phase transformation origin of nanoscale plastic deformation of semiconductor nanoobjects.
Źródło:
Acta Physica Polonica A; 2017, 131, 5; 1318-1331
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykonanie otworów w ceglanych sklepieniach walcowych
Drilling holes in the barrel vaults
Autorzy:
Orłowicz, R.
Nowak, R.
Powiązania:
https://bibliotekanauki.pl/articles/161995.pdf
Data publikacji:
2017
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
konstrukcja murowa
sklepienie walcowe
otwór
rozkład naprężeń
Abaqus
masonry structure
cylindrical vault
opening
stress distribution
ABAQUS
Opis:
Zaprezentowano wybrane zagadnienia wykonania otworów w sklepieniach ceglanych dla przewodów inżynierii sanitarnej. Sklepienie zostało przebadane za pomocą symulacji MES w celu określenia jego stanu naprężeń. Został określony optymalny, czyli najmniej inwazyjny sposób kreowania otworów w sklepieniu. Otwór powinien przecinać sklepienie równolegle do trajektorii głównych naprężeń ściskających, minimalizując kierunek poprzeczny do tych linii.
The article presents selected hole drilling concepts in case of barrel vaults for sanitary engineering. The vault was tested using the finite element method (FEM simulation) to determine its stress state. We determined optimal, the least invasive way of creating holes in the vault. The opening should intersect the vault parallel to the trajectory of the major compressive stresses, minimizing the transverse direction to these lines.
Źródło:
Przegląd Budowlany; 2017, 88, 12; 30-31
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transformacje odcieków jako rezultat technicznych zabiegów na składowiskach odpadów komunalnych
Transformations of leachate as a result of technical treatment at municipal waste landfills
Autorzy:
Szymański, K.
Nowak, R.
Powiązania:
https://bibliotekanauki.pl/articles/1819399.pdf
Data publikacji:
2012
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
odcieki
odpady komunalne
skład chemiczny
Opis:
Research on landfill leachate proves that technical activities conducted on the site of the landfill of municipal waste: permanent compaction of waste, making strata between individual layers of waste, landfill degassing, partial reclamation of landfill quarters and landfilling of partially segregated waste, had a significant impact on change of physico-chemical composition of leachates over 32 years of its operation. It was found that there was a noticeable increase of pH which favours processes of elimination of certain mineral impurities including heavy metals. Concentration of phosphorus compounds occurring mainly in the form of phosphates decreased which can be explained by processes of precipitation and sedimentation of those compounds in leachates. There was a substantial increase in the concentration of ammonia nitrogen in individual years of the operation of the landfill in relation to the initial period, which shows the clear nature of reduction conditions in the generated leachate. Maximum concentrations of this parameter was noted after the fourth and fifth year of operation of the object. This promotes generation of landfill gas, which is used on the landfill site to produce electricity. There is still a high level of concentration of chlorides in landfill leachates. However, in relation to the 1983 and 1984 years, much lower concentrations of those pollutants in the evaluated medium is observed in the recent years. Presence of mineral impurities impacts on the sustaining increased parameters of dry residue and high conductivity. It should be noted that all forms of technical activities undertaken in the issue of landfill method of municipal waste disposal have a positive effect in generation of leachates containing currently far less pollutants than in previous years. It is necessary to conduct field monitoring of landfill leachates, permitting effective decisions regarding their treatment.
Źródło:
Rocznik Ochrona Środowiska; 2012, Tom 14; 337-350
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nośność stref podporowych wybranych sklepień ceglanych
Load bearing capacity of support zones of selected brick vaults
Autorzy:
Nowak, R.
Orłowicz, R.
Powiązania:
https://bibliotekanauki.pl/articles/161074.pdf
Data publikacji:
2018
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
obiekt zabytkowy
sklepienie ceglane
zmiana konstrukcyjna
strefa podporowa
nośność
historical building
brick vault
structural change
support zone
load bearing capacity
Opis:
W wielu budynkach historycznych podstawowymi konstrukcjami stropów i przekryć są sklepienia ceglane, które ze względu na walory dekoracyjne stanowią jedno z ważniejszych osiągnięć architektury gotyckiej. Stosowane w architekturze romańskiej sklepienia kolebkowe o kształcie połowy walca zastąpiono lżejszym sklepieniem krzyżowym. Po wieloletniej eksploatacji sklepienia te często budzą obawy odnośnie ich nośności i możliwości dalszego bezpiecznego użytkowania.
In many historical buildings, basic structures of ceilings and covers are brick vaults, which owing to their decorative qualities constitute one of the most important achievements of gothic architecture. The barrel vaults used in Romanesque architecture, which had a shape of a half-roller, were replaced with lighter cross vaults. After many years of exploitation, these vaults often raise concerns about their load-bearing capacity and the possibility of further safe use.
Źródło:
Przegląd Budowlany; 2018, 89, 11; 38-40
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Szczególny przypadek uszkodzenia ceglanych nadproży łukowych
A special case of damage to brick arch lintels
Autorzy:
Orłowicz, R.
Nowak, R.
Powiązania:
https://bibliotekanauki.pl/articles/163227.pdf
Data publikacji:
2010
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
budynek murowany
nadproże ceglane
nadproże łukowe
ściana szczytowa
uszkodzenie
przyczyna uszkodzeń
masonry building
brick header
arch header
gable wall
damage
damage cause
Opis:
Podano mechanizmy i przyczyny uszkodzeń ceglanych nadproży łukowych w istniejących budynkach. Szczególnym przypadkiem tych uszkodzeń są spękania nadproży usytuowanych w sąsiedztwie ścian szczytowych. Z uwagi na działanie niezrównoważonego rozporu w tej strefie mogą powstać spękania pionowe pasm międzyokiennych. Skutkiem tego może być utrata stateczności ściany szczytowej i zmniejszenie sztywności budynku jako układu przestrzennego.
This article describes the mechanisms and reasons for damage to brick arch lintels in existing buildings. A special case of such damage involves cracking of lintels situated in the vicinity of gable walls. Due to the action of unbalanced thrust in this zone, there may occur vertical cracks in the bands between windows. This may lead to loss of stability of the gable wall and a reduction in the building's rigidity as a three-dimensional structure.
Źródło:
Przegląd Budowlany; 2010, R. 81, nr 4, 4; 30-32
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza kosztów funkcjonowania przydomowych oczyszczalni ścieków
Analysis of Operating Costs of Domestic Sewage Treatment Plants
Autorzy:
Nowak, R.
Wawryca, M.
Powiązania:
https://bibliotekanauki.pl/articles/1818125.pdf
Data publikacji:
2015
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
oczyszczanie ścieków
przydomowe oczyszczalnie ścieków
ocena ekonomiczna
wastewater treatment
domestic sewage treatment plants
economic analysis
Opis:
The economics aspects of the operation of household wastewater treatment plants are discussed in the paper. Three selected individual wastewater treatment systems offered by HABA are presented, such as (1) system with drainage tunnel (HABA DT), (2) treatment plant of SBR type (HABA SBR PRIMO) and (3) constructed wetland wastewater treatment plant (HABA ORS). In the work the analytical procedures for determining the costs are presented. Next, a comparative economics analysis of these systems is carried out. The level of annual costs as well as unit costs of wastewater disposal and treatment are determined for these systems. The annual unit cost in presented small sewage treatment facilities ranged from 4.83 to 6.00 zł per m3. The calculations showed that the lowest annual cost of wastewater treatment is characterized by a system with drainage tunnel. Of the three systems included in the work of the highest costs of wastewater treatment plant generates system HABA ORS.
Źródło:
Rocznik Ochrona Środowiska; 2015, Tom 17, cz. 1; 680-691
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Obliczenia osiowego strumienia magnetycznego w maszynie indukcyjnej metodą elementów skończonych
Smoothing of the flux operating characteristic in electrical drives with field weakening
Autorzy:
Dębowski, A.
Nowak, R.
Powiązania:
https://bibliotekanauki.pl/articles/1369623.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
napędy elektryczne
osłabianie pola
wygładzanie charakterystyki zadawania strumienia
Opis:
The paper presents a particular problem with determining the permissible boundaries of the working area for two-zone asynchronous traction drive with high dynamic requirements, designed to work in a very broad range of motor rotational speed. A result of the procedure of maximizing the internal motor torque, based on an analysis of equations for drive steady-state model, is the family of nonlinear characteristics of the main magnetic flux values desired by the control system, expressed as a function of shaft rotational speed and parameterized with the selected values of the overhead line voltage. On the border between two areas - the first one, at low rotation of the motor shaft, when the magnetic flux remains constant, and the second one, when the magnetic flux is significantly weakened with the increase in shaft speed, these characteristics have asignificant discontinuity in the first derivative, ie. "edge". It can cause quite often unwanted oscillations in the driver control system operation during the dynamic transitions of a drive working point from one zone to another. The paper contains a proposal to reduce this phenomenon by applying a suitable technique of spline functions to smooth the characteristics of the magnetic flux reference values.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2012, 3, 96; 147-152
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ degradacji połączenia generatora piezoelektrycznego z belką na pozyskiwaną energię elektryczną
Influence of the piezoelectric generator-beam coupling degradation on energy harvesting
Autorzy:
Nowak, R.
Pietrzakowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/404246.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Symulacji Komputerowej
Tematy:
piezoelektryk
MES
ANSYS
pozyskiwanie energii elektrycznej
degradacja kleju
piezoelectric
FEM
energy harvesting
glue degradation
Opis:
Efektywność odzysku energii elektrycznej z energii drgań mechanicznych zależy między innymi od jakości połączenia pomiędzy generatorem piezoelektrycznym a belką. W niniejszym artykule przeprowadzono obliczenia belki wysięgnikowej wymuszonej ruchem harmonicznym podpory. Porównano wyniki otrzymane metodą analityczną i metodą elementów skończonych. Skupiono się na wpływie degradacji połączenia na charakterystyki dynamiczne układu i odzyskiwane napięcie. Porównano charakterystyki amplitudowo-częstotliwościowe w przypadku uszkodzonej i nieuszkodzonej warstwy kleju. Przeprowadzono badania w zależności od położenia obszaru degradacji i stopnia zniszczenia warstwy kleju.
Efficiency of energy harvesting depends on the coupling of the piezoelectric generator and the beam. Calculations of the cantilever beam excited by harmonic movement of the support has been executed in this article. Comparison of the results performed by analytical method and finite element method has been done. Influence on dynamic behavior of the system and generated voltage caused by glue layer degradation was made. Amplitude-frequency characteristics has been compared for damaged and undamaged glue layer. Placement and degree of damage of the glue layer was researched in case of effect onto generated voltage.
Źródło:
Symulacja w Badaniach i Rozwoju; 2013, 4, 4; 185-192
2081-6154
Pojawia się w:
Symulacja w Badaniach i Rozwoju
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metale ciężkie jako niepożądane składniki wód popłucznych pochodzących z uzdatniania wód podziemnych
Heavy metals as unwanted components of backwash water derived from groundwater treatment
Autorzy:
Nowak, R.
Imperowicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/400833.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
metale ciężkie
uzdatnianie wody
wody popłuczne
heavy metals
water treatment
backwash water
Opis:
W artykule przedstawiono wybrane aspekty problemu występowania metali ciężkich w ściekach i osadach, będących produktami odpadowymi w procesach uzdatniania wody. W pierwszej części pracy omówiono zagadnienia jakości powstających ścieków i osadów oraz działania, zmierzające do unieszkodliwiania takich odpadów. W dalszej części pracy, na przykładzie 12 stacji uzdatniania wód podziemnych w konkretnej gminie, przedstawiono problem jakości wód popłucznych, w szczególności występowania w nich metali ciężkich. Analiza obejmowała okres trzech lat: 2013, 2014 i 2015. Autorzy na przykładzie przedstawionych obiektów wykazali, że w wodach popłucznych z uzdatniania wód podziemnych, poza uwodnionymi tlenkami żelaza i manganu, mogą występować inne, toksyczne zanieczyszczenia. W szczególności analiza jakościowa popłuczyn wykazała obecność metali ciężkich, głównie cynku. Wyniki badań wód popłucznych porównano z wynikami oceny jakościowej filtratu, w którym metali ciężkich nie stwierdzono. Fakt ten wskazywał na zatrzymanie metali w złożu filtracyjnym i jednocześnie nietrwałe ich w nim umocowanie, czego skutkiem było przedostawanie się metali ciężkich ze złoża do wód popłucznych wraz z innymi zanieczyszczeniami, głównie tlenkami żelaza i manganu. Zasadniczym wnioskiem, płynącym z pracy, jest wykazanie konieczności stałego monitorowania jakości popłuczyn, w tym pod kątem obecności toksycznych metali ciężkich. Jest to istotne także ze względu na wymóg maksymalnego ograniczenia negatywnego oddziaływania na środowisko odpadów, wytwarzanych w procesie uzdatniania wody.
The paper presents some aspects of the problem of heavy metals presence in wastewater and sewage sludge from water treatment. In the first part, issues on quality of wastewaters and sludge produced during water treatment along with actions aimed at the neutralization of such wastes, were discussed. Subsequent parts of the work present the example of 12 groundwater treatment stations in a particular municipality, and the problem of backwash water quality, in particular, heavy metals contents. The analysis covered a period of three years: 2013, 2014, and 2015. The authors, using the discussed examples, have shown that besides hydrated iron and manganese oxides, also other toxic contaminants can be present in backwash water from groundwater treatment. In particular, the qualitative analysis of the backwash water revealed the presence of heavy metals, mainly zinc. The test results for backwash water were compared with those of filtrate qualitative assessment, wherein the heavy metals were not found. This fact indicated the metal retention in the filter bed and their unsustainable immobilization resulting in penetration of heavy metals from deposit to the backwash water along with other impurities, mainly iron and manganese oxides. The main conclusion from the study is to demonstrate the need for constant monitoring of the backwash water quality, including the presence of toxic heavy metals. This is also important because of the requirement to minimize the negative environmental impact of wastes generated during the water treatment process.
Źródło:
Inżynieria Ekologiczna; 2016, 48; 166-173
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Symulacyjne badanie efektywności belkowego generatora piezoelektrycznego
Simulation investigation of the piezoelectric beam generator efficiency
Autorzy:
Nowak, R.
Pietrzakowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/404007.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Symulacji Komputerowej
Tematy:
pozyskiwanie energii elektrycznej
generator piezoelektryczny
efektywność
dobór parametrów
płaski i bryłowy model MES
energy harvesting
piezoelectric generator
efficiency
parameter selection
plane and solid FEM models
Opis:
Rozważania dotyczą układu pozyskiwania energii elektrycznej w postaci trójwarstwowej belki wysięgnikowej, składającej się ze stalowej warstwy środkowej i zewnętrznych warstw piezoelektrycznych. Odkształcenie belki wywołano przemieszczeniem jej swobodnego końca o ustalonej wartości. W pracy zbadano wpływ parametrów geometrycznych i materiałowych generatora belkowego na pozyskiwane napięcie i energię elektryczną. W porównawczych obliczeniach metodą elementów skończonych, przeprowadzonych przy zastosowaniu modeli płaskich i bryłowych, wykazano dostateczną dokładność modeli płaskich. Wyniki otrzymane uproszczoną metodą analityczną i metodą elementów skończonych przedstawiono graficznie w postaci zależności napięcia lub energii od stosunku grubości warstw. Dla wybranych sztywności warstw wyznaczono wartości stosunku ich grubości, którym odpowiada największa efektywność generatora. Zbliżone wyniki uzyskano w przypadku obu metod obliczeniowych.
The cantilever beam energy harvester consists of three layers, steel in the middle and the two outer piezoelectric layers, was considered. The strain of the beam was caused by the free end static deflection. The influence of the material and the geometry parameters of the beam generator on the generated voltage and the electrical energy was investigated. Sufficient accuracy of the plain and the solid FEM models were proved. The results obtained in the analytical and the FEM ways was compared and shown graphically as the relationship between the generated voltage or energy and the layer thickness ratio. The most effective, from the energy harvesting point of view, thickness and stiffness ratio of the layers was founded. The similar results from both calculation methods were obtained.
Źródło:
Symulacja w Badaniach i Rozwoju; 2015, 6, 4; 265-272
2081-6154
Pojawia się w:
Symulacja w Badaniach i Rozwoju
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nieczystości płynne ze zbiorników bezodpływowych jako źródło zanieczyszczeń mikrobiologicznych wód podziemnych
Liquid waste from septic tanks as a source of microbiological pollution of groundwater
Autorzy:
Nowak, R.
Imperowicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/400687.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
kanalizacja bezodpływowa
zanieczyszczenia mikrobiologiczne
jakość wód podziemnych
sewage holding tank system
microbiological pollutions
groundwater quality
Opis:
W Polsce ogromnym problemem jest zanieczyszczenie środowiska gruntowo-wodnego przez nieczystości płynne, pochodzące ze zbiorników bezodpływowych. Dotyczy to szczególnie terenów wiejskich. Negatywne zmiany stwierdzane są zarówno w sąsiedztwie nieszczelnych zbiorników, z których zagęszczone i zagniłe ścieki infiltrują do gruntu, jak i w wodach powierzchniowych i gruntach ornych, do których trafiają nieczystości z opróżnianych zbiorników. W pracy, na przykładzie wybranej gminy, przedstawiono skalę występowania procederu niekontrolowanego odprowadzania ścieków bytowych do środowiska. Zaprezentowane dane porównano z wynikami oceny jakościowej wód podziemnych, ujmowanych w tej samej gminie do celów wodociągowych. W znaczącej części studni woda nie była bezpieczna pod względem sanitarnym, bowiem stwierdzono w niej obecność m.in. zanieczyszczeń mikrobiologicznych. Wśród oznaczonych mikroorganizmów dominowały organizmy wskaźnikowe zanieczyszczenia wód ściekami bytowymi. Problemy z jakością wody zostały odnotowane na ujęciach, zlokalizowanych w pobliżu posesji, wyposażonych w zbiorniki bezodpływowe lub w miejscach, do których w niekontrolowany sposób trafiały ścieki z opróżnianych zbiorników. W ten sposób wykazano, że istnieje związek między niewłaściwie prowadzoną gospodarką ściekową a jakością wód podziemnych, ujmowanych do celów wodociągowych.
Pollution of soil and water environment by liquid waste originating from septic tanks is a huge problem in Poland. This applies especially to rural areas. Negative changes are observed both in the vicinity of the leaking tanks, from which concentrated and rotten sewage infiltrates into the ground, and in surface water as well as arable land, to which impurities from the emptied tanks are discharged. The paper presents the scale of the practice of uncontrolled domestic sewage discharge into the environment on the example of selected municipality. Presented data were compared with the results of the qualitative assessment of groundwater, which is collected in the same municipality for waterworks. In a significant number of wells, water was not safe in sanitary terms, as the presence of microbiological contamination was recorded. Among determined microorganisms, the indicator organisms of domestic waste pollution prevailed. Water quality problems have been reported at intake points located near the properties equipped with septic tanks or in places, to which sewage from emptying septic tanks were transferred in an uncontrolled manner. In this way it has been shown that there is a relationship between improperly maintained wastewater management and groundwater quality collected for the purpose of water supply.
Źródło:
Inżynieria Ekologiczna; 2016, 47; 60-67
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Frakcje chemiczne metali ciężkich w osadach ściekowych i w stałej pozostałości po ich spaleniu
Chemical fractions of heavy metals in sewage sludge and in residue after incineration of sewage sludge
Autorzy:
Dąbrowska, L.
Nowak, R.
Powiązania:
https://bibliotekanauki.pl/articles/297150.pdf
Data publikacji:
2014
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
osady ściekowe
spalanie
metale ciężkie
ekstrakcja sekwencyjna
sewage sludge
incineration
heavy metals
sequential extraction
Opis:
Spalanie osadów ściekowych powoduje, że stężenie metali ciężkich w powstałych stałych pozostałościach jest wyższe niż w osadach, z drugiej jednak strony może przyczynić się do przemian chemicznych w mniej mobilne formy metali. Celem badań było wykazanie, w jakich formach chemicznych występują metale w wybranych osadach ściekowych oraz w stałej pozostałości otrzymanej po ich spaleniu w temperaturze 800°C. Frakcjonowanie metali (Cu, Zn, Cd, Ni, Pb, Cr) w osadach ściekowych i w pozostałości po spaleniu osadów przeprowadzono zgodnie z procedurą ekstrakcji sekwencyjnej BCR. Wykazano, że w osadach ściekowych metale związane były głównie z frakcją organiczno-siarczkową (52÷90% całkowitej ilości). W znaczących ilościach cynk i kadm występowały również we frakcji tlenków żelaza i manganu, nikiel we frakcji wymienno-węglanowej, natomiast ołów we frakcji rezydualnej, uważanej za trudno dostępną i chemicznie stabilną (metale znajdujące się w siatce krystalograficznej minerałów). Potwierdzono, że w stałych pozostałościach po spaleniu osadów stężenia metali we frakcjach rezydualnych były wyższe w odniesieniu do stężeń w tych frakcjach w osadach. Najwyższą zawartość w tej frakcji uzyskano dla chromu (98%), cynku (91÷95%), ołowiu (85÷96%), niklu (82÷92%), miedzi (74÷85%).
Sewage sludge combustion results in increase of heavy metal concentration in obtained ash, however it may contribute to chemical transitions into less mobile forms (heavy metals bond to residual fraction). The aim of this research was to determine whether sewage sludge combustion at temperature of 800°C results in formation of non-mobile forms of heavy metals in obtained ash. Dried sewage sludge samples were collected at two different mechanical-biological wastewater treatment plants. For sewage sludge and residue on ignition (ash) heavy metal speciation analysis according to BCR procedure was conducted. It is shown that in sewage sludge heavy metals are mainly associated with the organic sulfide fraction. The significant amounts of zinc were also present in the fraction of iron and manganese oxides, of nickel and cadmium in the exchangeable-carbonate fraction, and of lead in the residual fraction. In ash obtained after incineration in temperature of 800°C there occurred mainly metal enrichment of nearly insoluble compound fraction (residual fraction). The content of chromium in this fraction was 98%. The residual fraction is considered to be chemically stable and biologically inactive. For other metals: zinc, lead, and nickel, their content in the residual fraction was 91÷95; 85÷96; 82÷92%, respectively. The accumulation of the metals in the residual fraction is beneficial from the perspective of groundwater protection.
Źródło:
Inżynieria i Ochrona Środowiska; 2014, 17, 3; 403-414
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of products of adhesive wastewater oxidation with Fentons reagent on biological treatment in SBR
Autorzy:
Piaskowski, K.
Nowak, R.
Powiązania:
https://bibliotekanauki.pl/articles/207366.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
bioremediacja
oczyszczanie ścieków
procesy utleniania
oczyszczanie biologiczne
utlenianie chemiczne
oczyszczanie ścieków przemysłowych
ścieki przemysłowe
bioremediation
wastewater treatment
oxidation processes
biological purification
biological treatment
chemical oxidation
industrial wastewater treatment
industrial wastewaters
Opis:
The advanced oxidation process with Fenton’s reagent can be used in industrial wastewater treatment, especially for the degradation of not easily biodegradable contaminations. Chemical oxidation of industrial wastewater or other substances as a pre-treatment before biological purification is the most effective method of wastewater treatment. However the Fenton process requires low pH of wastewater and final neutralization with a big amount of iron-containing precipitate. Thes paper presents laboratory experiments dealing with the treatment of adhesive wastewater in an sequencing batch reactor following the Fenton process without final neutralization.
Źródło:
Environment Protection Engineering; 2013, 39, 4; 51-62
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie złóż tarczowych do usuwania azotu amonowego w warunkach ograniczonego dostępu tlenu
Removal of ammonium nitrogen under low oxygen concentration using rotating contactor
Autorzy:
Nowak, R.
Włodarczyk-Makuła, M.
Powiązania:
https://bibliotekanauki.pl/articles/372117.pdf
Data publikacji:
2015
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
azot amonowy
stężenie tlenu
złoża tarczowe
ammonium nitrogen
oxygen concentration
rotating contactor
Opis:
W artykule przedstawiono wyniki badań dotyczące skuteczności usuwania azotu amonowego na złożach tarczowych w warunkach deficytu tlenowego. Badania prowadzono z wykorzystaniem ścieków syntetycznych przy dwóch różnych stężeniach azotu amonowego (średnio 250 i 500 mg N-NH4 +/dm3) na złożach tarczowych. Utlenianie azotu amonowego zawartego w ściekach prowadzono w dwóch układach: pracującym w warunkach tlenowych (układ kontrolny) oraz w warunkach ograniczonego dostępu tlenu (układ badawczy). Wykazano, że w warunkach deficytu tlenowego efektywność usuwania azotu amonowego z oczyszczanych ścieków sięgała 85%.
The article presents results of research on ammonia nitrogen removal efficiency under low oxygen concentration using rotating contractor. Synthetic wastewater with an increasing level of ammonium nitrogen (250 and 500 mg N-NH4 +/dm3) and rotating contactors inhabited by nitrifying bacteria were used during the study. Ammonium nitrogen oxidation was carried out in two simultaneously working laboratory installations: under aerobic conditions (control system) and under low oxygen concentration (research system). The experiment showed that despite the oxygen deficit it was possible to achieve more than 85% ammonium nitrogen removal from the treated wastewater.
Źródło:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski; 2015, 159 (39); 75-88
1895-7323
Pojawia się w:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An experimental analysis of the flow structure in various configurations of a circular-planar SOFC fuel channel
Analiza eksperymentalna struktury przepływu gazu w zróżnicowanychprzepływu gazu w zróżnicowanych geometriach kanału paliwowego ogniwa paliwowego typu SOFC
Autorzy:
Nowak, R.
Szmyd, J. S.
Powiązania:
https://bibliotekanauki.pl/articles/281000.pdf
Data publikacji:
2011
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
particle image velocimetry
error analysis
flow distribution
SOFC
Opis:
In the presented paper, the authors focus on the analysis of flow structure in various configurations of a circular-planar SOFC fuel channel. The research was carried out on the premise that a proper channel design would help minimize the thermal stress in the cell, which is affected by the heat generated and consumed by the reforming, water gas-shift and hydrogen consumption reactions. For the measurement process, PIV method was used to calculate the velocity fields, and an extensive error analysis was done to evaluate the accuracy of the calculated velocities.
W zaprezentowanym artykule, tematem realizowanych badań jest analiza eksperymentalna struktury przepływu gazu w trzech modelach kanałów transportowych ogniwa paliwowego typu SOFC (Solid Oxide Fuel Cell). Celem badań było zaproponowanie geometrii kanału, która pozwoliłaby utrzymać jednorodny rozkład pola prędkości na powierzchniach elektrod w rzeczywistych warunkach pracy ogniwa. Dobór odpowiedniej geometrii kanałów transportowych jest istotny z punktu widzenia wydajności oraz bezpieczeństwa pracy ogniwa, ponieważ bezpośrednio wpływa na wydajność reakcji elektrochemicznych zachodzących w ogniwie oraz na rozkład temperatury w jego wnętrzu, uwarunkowany silnie egzotermicznymi reakcjami elektrodowymi oraz w przypadku wykorzystania paliwa węglowodorowego dodatkową, endotermiczną reakcją reformingu i egzotermiczną reakcją tlenku węgla z parą wodną. Na potrzeby eksperymentu zaprojektowano oraz wykonano z pleksi trzy przykładowe geometrie kanałów przepływowych. Badania eksperymentalne przeprowadzono w temperaturze pokojowej. Gazem wykorzystanym w badaniach było powietrze. Bazując na teorii podobieństwa ustalono wartości liczby Reynoldsa na poziomie odpowiadającym wielkościomliteraturowym, dzięki czemu otrzymane wyniki można traktować jako wiarygodne i oddające charakter przepływu paliwa w rzeczywistym ogniwie paliwowym. Profile prędkości wyznaczono wykorzystując bezinwazyjną metodę Particle Image Velocimetry. Ponadto, na podstawie analizy błędów określono zestaw parametrów obliczeniowych, dla których wyznaczone pole wektorowe charakteryzowało się największą dokładnością.
Źródło:
Journal of Theoretical and Applied Mechanics; 2011, 49, 2; 541-564
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nanoscale deformation of GaAs affected by silicon doping
Autorzy:
Majtyka, A.
Nowak, R.
Chrobak, D.
Powiązania:
https://bibliotekanauki.pl/articles/1112264.pdf
Data publikacji:
2016-10
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
64.70.kg
61.72.J-
Opis:
Effect of silicon doping on the elastic-plastic transition of GaAs crystal is demonstrated by results of nanoindentations and ab initio simulations. The performed experiments show that an increase of silicon concentration causes a decrease of the contact pressure at the onset of permanent nanodeformation of GaAs crystal. Ab initio calculations demonstrate that presence of Si atoms in the crystal lattice suppresses the shear modulus as well as the pressure of equilibrium between zinc-blende and rock-salt phases of GaAs. Furthermore, it is argued that the effect of dislocations pinning to Si dopants is essential for clarification of GaAs yielding.
Źródło:
Acta Physica Polonica A; 2016, 130, 4; 1127-1130
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Control and visualisation of illumination and irrigation processes
Autorzy:
Nowak, R.
Pietrasz, A.
Trzmiel, G.
Powiązania:
https://bibliotekanauki.pl/articles/97529.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
control
visualisation
SCADA system
integrated control system
Opis:
The paper presents the design of the integrated illumination and irrigation system using a PLC and its visualisation. In the introduction, the history of PLCs and the SCADA software was briefly described. It was followed by the presentation of the design intent, the description of its operation and components. The control algorithm created especially for this design, the programme for the selected controller and visualisation prepared in VijeoCitect software were also described. The last part of the paper contains the summary of the design and the trends for its development.
Źródło:
Computer Applications in Electrical Engineering; 2016, 14; 469-484
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sterowanie i wizualizacja w instalacjach budynku inteligentnego
Control and visualization in intelligent building installations
Autorzy:
Nowak, R.
Pietrasz, A.
Trzmiel, G.
Powiązania:
https://bibliotekanauki.pl/articles/376667.pdf
Data publikacji:
2018
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
budynek inteligentny
sterowanie
wizualizacja
Opis:
W pracy odniesiono się do przedstawienia projektu systemu sterowania komfortem i bezpieczeństwem w budynku oraz wizualizacji systemów współpracujących w ramach tego układu. We wstępie przedstawiono definicję budynku inteligentnego oraz opis sterowników PLC i oprogramowania typu SCADA. W dalszej części zaprezentowane zostały założenia projektowe wraz z opisem działania zaprojektowanego układu. Opisane zostały również opracowane algorytmy sterowania procesami, program sterownika, a także stworzona wizualizacja. Praca zwieńczona została podsumowaniem.
The paper presents of the project of comfort and security management in a building and its visualization. In the introduction, the definition of intelligent building, PLC controllers and SCADA software were briefly portrayed. The following is a presentation of the design intent and operations description. The control algorithms, program for the selected controller and SCADA visualization were also described. The last part of the paper contains the summary.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2018, 96; 185-196
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elastic constants and analytic bond order potential for atomistic simulations of simple cubic tungsten trioxide
Autorzy:
Dendzik, Z.
Chrobak, D.
Nowak, R.
Powiązania:
https://bibliotekanauki.pl/articles/1943224.pdf
Data publikacji:
2009
Wydawca:
Politechnika Gdańska
Tematy:
tungsten trioxide
DFT
elastic constans
bond-order potential
Opis:
A set of elastic constants was calculated and a parametrization of the potential was derived for simple cubic tungsten trioxide based on an analytical bond-order scheme. It was show that the obtained parametrization provided a good description of interatomic forces and such properties as the lattice constant, the bulk modulus and the elastic constants.
Źródło:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk; 2009, 13, 1-2; 93-98
1428-6394
Pojawia się w:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sterowanie i wizualizacja procesów oświetlenia i nawodnienia ogrodu – część 1
Control and visualisation of illumination and irrigation processes
Autorzy:
Nowak, R.
Pietrasz, A.
Trzmiel, G.
Powiązania:
https://bibliotekanauki.pl/articles/377304.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
sterowanie
wizualizacja
system SCADA
sterownik PLC
Opis:
W pracy odniesiono się do przedstawienia projektu zintegrowanego systemu oświetlenia i nawadniania ogrodowego z wykorzystaniem sterownika PLC i jego wizualizacji. We wstępie wspomniano pokrótce historię sterowników oraz opisano oprogramowanie SCADA. W dalszej części przedstawiono założenia projektowe, opis działania oraz elementy składowe. Opisano także wykonany na potrzeby projektu algorytm sterowania, program dla wybranego sterownika oraz wizualizację przygotowaną w programie VijeoCitect. Na końcu podsumowano projekt oraz opisano możliwości jego rozwoju.
The paper presents of the project of integrated illumination and irrigation system using a PLC controller ant its visualisation. In the introduction, the history PLC controllers and SCADA software were briefly portrayed. The following is a presentation of the design intent, operations description and included components. The control algorithm created specially for the project, programme for the selected controller and visualisation prepared in Vijeo Citect programme were also described. The last part contains project summary and its development trends.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2016, 88; 387-398
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania laboratoryjne superkondensatorowego zasobnika energii przeznaczonego do ograniczania strat w sieciach trakcyjnych
Laboratory Tests of Supercapacitor Energy Storage Designed for Energy Loss Reduction in Traction Networks
Autorzy:
Chudzik, P.
Radecki, A.
Nowak, R.
Powiązania:
https://bibliotekanauki.pl/articles/1368482.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
straty energii
napęd trakcyjny
zasobnik superkondensatorowy
energy losses
electric vehicle traction drive
ultracapacitor energy-storage device
Opis:
In this article a laboratory test-stand designed for development and study of traction power losses optimization algorithms of ultracapacitor control was presented. Described in article a laboratory test-stand allows to model a traction power grid with motor drive load and controlled super-capacitor energy storage. It was proposed to use real measurements recorded in traction vehicles on their typical working profiles to use for identification of traction power grid parameters and drive load. Waveforms showing a working state of modeled grid traction with drive load was included in article.
W artykule przedstawiono strukturę stanowiska badawczego przeznaczonego do prowadzenia badań nad algorytmami sterowania superkondensatorowymi zasobnikami energii, stosowanymi w pojazdach trakcyjnych dla podniesienia sprawności energetycznej ich układów napędowych. Opisano problematykę ograniczania strat przesyłowych i strat powstających na skutek braku możliwości oddania do sieci energii odzyskanej podczas hamowania dynamicznego układu napędowego. Zaproponowano wykorzystanie do badań nad algorytmami sterowania zasobnikiem rzeczywistych danych pomiarowych, zarejestrowanych podczas jazdy tramwajów i trolejbusów w kilku polskich miastach. Przedstawiono metodę identyfikacji parametrów sieci trakcyjnej i zamieszczono przykładowe wyniki obrazujące zmienność parametrów układów zasilania pojazdu w funkcji czasu na skutek obecności na tym samym odcinku zasilania innych pojazdów. Opisano budowę stanowiska badawczego oraz omówiono zasady działania poszczególnych jego części składowych. W artykule został przedstawiony zakres badań możliwych do wykonania z wykorzystaniem opracowanego stanowiska laboratoryjnego oraz zamieszczono przebiegi wybranych prądów i napięć obrazujące działanie urządzenia.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 2, 99; 173-177
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przyczyny uszkodzeń i naprawa wybranych zabytkowych sklepień ceglanych
Causes of damages and repairsin antique brick vaults
Autorzy:
Rzeszotarski, A.
Orłowicz, R.
Nowak, R.
Powiązania:
https://bibliotekanauki.pl/articles/217735.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Konserwatorów Zabytków
Tematy:
sklepienie ceglane
uszkodzenie
brick vault
damage
Opis:
W referacie omówiono dwa przykłady zastosowania szkła o dużych rozpiętościach, pełniącego funkcje konstrukcyjne, do ekspozycji elementów zabytkowych w budynkach. Szkło, ze względu na swą przezierność i neutralność architektoniczną pozwala na zachowanie cennych elementów zabytkowych tak, że pozostają one wbudowane tam, gdzie je odkryto, mogą być elegancko wyeksponowane, a jednocześnie funkcja budynku nie jest w żadnym stopniu zaburzona. To rozwiązanie jakże częstych dylematów przy pracy z budynkami historycznymi: funkcjonalność nowoczesności - czy zachowanie historycznych wartości? Co poświęcić kosztem czego? Omówiona technologia w wielu przypadkach będzie rozwiązaniem zaspokajającym obie te potrzeby. A kluczowym argumentem może być jej łatwa dostępność i możliwość realizacji tu w Polsce.
The lecture describes two examples of the application, where a wide range glass is being used, as a structural component, in order to expose historic parts of the building. Glass, being transparent and architectural neutral allows preserving valuable historic elements especially that they remain integrated just as they were discovered, yet elegantly displayed, while at the same time none of the building's function is impaired. It is a solution for common dilemmas when working with a historic building: functionality of modern ways or rather preserving its historic value? Which will be scarified as a cost? The described technology in many cases will fulfils both of those needs equally. And the key argument could be its availability and capability for its realization here in Poland.
Źródło:
Wiadomości Konserwatorskie; 2009, 26; 260-269
0860-2395
2544-8870
Pojawia się w:
Wiadomości Konserwatorskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sterowanie i wizualizacja procesów oświetlenia i nawodnienia ogrodu – część 2
Control and visualisation of illumination and irrigation processes
Autorzy:
Nowak, R.
Pietrasz, A.
Trzmiel, G.
Powiązania:
https://bibliotekanauki.pl/articles/378110.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
sterowanie
wizualizacja
system SCADA
sterowniki PLC
Opis:
W pracy odniesiono się do przedstawienia projektu zintegrowanego systemu oświetlenia i nawadniania ogrodowego z wykorzystaniem sterownika PLC i jego wizualizacji. We wstępie wspomniano pokrótce historię sterowników oraz opisano oprogramowanie SCADA. W dalszej części przedstawiono założenia projektowe, opis działania oraz elementy składowe. Opisano także wykonany na potrzeby projektu algorytm sterowania, program dla wybranego sterownika oraz wizualizację przygotowaną w programie VijeoCitect. Na końcu podsumowano projekt oraz opisano możliwości jego rozwoju.
The paper presents of the project of integrated illumination and irrigation system using a PLC controller ant its visualisation. In the introduction, the history PLC controllers and SCADA software were briefly portrayed. The following is a presentation of the design intent, operations description and included components. The control algorithm created specially for the project, programme for the selected controller and visualisation prepared in Vijeo Citect programme were also described. The last part contains project summary and its development trends.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2016, 88; 399-409
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Symulacyjne badanie skutków degradacji połączenia piezoaktuatora z belką
Simulation investigation of degradation effects of the piezoactuator-beam coupling
Autorzy:
Hoffman, G
Nowak, R.
Pietrzakowski, M
Powiązania:
https://bibliotekanauki.pl/articles/404212.pdf
Data publikacji:
2012
Wydawca:
Polskie Towarzystwo Symulacji Komputerowej
Tematy:
aktuator piezoelektryczny
belka
degradacja połączenia
MES (metoda elementów skończonych)
metoda elementów skończonych
model MES
piezoelectric actuator
beam
coupling degradation
FEM
finite element method
FEM model
Opis:
Efektywność współpracy piezoelektrycznego aktuatora z układem głównym zależy między innymi od jakości połączenia. Dlatego też degradacja warstwy łączącej jest ważnym aspektem badawczym. W niniejszej pracy przedmiotem badań jest belka swobodnie podparta z przyklejonym na jej powierzchni piezoelektrycznym aktuatorem, którego działanie wywołuje zginanie belki. Uszkodzenie zamodelowano jako zmianę sztywności ścinania warstwy kleju w ustalonym, zdegradowanym obszarze wzdłuż brzegu aktuatora. W celu weryfikacji modeli MES (opracowanych w dwóch programach ABAQUS i ANSYS) porównano wyniki symulacji z wynikami uzyskanymi metodą analityczną. Skupiono się na porównaniu rozkładów naprężeń stycznych w warstwie kleju w części uszkodzonej i nieuszkodzonej, ugięć belki oraz charakterystyk amplitudowo-częstotliwościowych w przypadku różnych sztywności warstwy. Uzyskana dostateczna zgodność wyników uzasadnia poprawność zastosowanych modeli MES.
Efficiency of a piezoelectric actuator-beam interaction depends on the coupling quality. That is why glue layer degradation is one of the important research problems. Consideration of a simply supported beam with a surface mounted piezoelectric patch, which operates in bending mode, has been presented in this article. The glue degradation has been modeled as a modification of shear stiffness within the assumed area along the actuator edge. Verification of the FEM models (built using two programs ANSYS and ABAQUS) was performed comparing results with those obtained applying the analytical method. The comparison is focused on the results such as shear stresses distributions within the damaged and undamaged glue layer, beam deflections and amplitude-frequency characteristics calculated for different shear stiffness values. The results are in quite good agreement and prove correctness of the applied FEM models.
Źródło:
Symulacja w Badaniach i Rozwoju; 2012, 3, 1; 19-28
2081-6154
Pojawia się w:
Symulacja w Badaniach i Rozwoju
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wektorowy falownik napięciowy z pomiarem rzeczywistego napięcia wyjściowego
Voltage Inverter with True Output Voltage Measurement System
Autorzy:
Nowak, R.
Chudzik, P.
Sobieraj, T.
Powiązania:
https://bibliotekanauki.pl/articles/1368427.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
mikrokontroler z rdzeniem ARM
układ programowalny FPGA
falownik tranzystorowy
modulacja wektorowa
silnik synchroniczny z magnesami trwałymi
ARM microcontroller
field programmable gate array (FPGA)
transistor inverter
vector modulation
PMSM motor
Opis:
The paper presents a power converter designed in the Institute of Automatic Control Lodz University of Technology intended for laboratory tests PMSM motors. The main feature of the presented device is the ability to flexibly configure the control unit that contains both the ARM microcontroller core and the reconfigurable FPGA system. Thanks to this solution one has possibility of testing the drive control algorithms intended for use in both the sequential circuits (MCUs), as well as programmable circuits (FPGA). Advantage is the possibility of synergistic implementation of the algorithm, the division between the two currently most widely used computing architectures. Describes the specially designed true output voltage measurement system. This proprietary solution allows not only to reduce the demands on the performance of analog components used in the construction of the measuring circuit, but also significantly relieve the unit of account by the control system. The paper contains a discussion of the assumptions and algorithms design performance. It also provides selected waveforms in typical operating conditions of the system.
W artykule przedstawiono wektorowy falownik napięciowy zaprojektowany w Instytucie Automatyki Politechniki Łódzkiej przeznaczony do badań laboratoryjnych silników synchronicznych z magnesami trwałymi. Główną cechą prezentowanego urządzenia jest możliwość elastycznej konfiguracji jednostki sterującej wyposażonej zarówno w mikrokontroler z rdzeniem ARM, jak również układ rekonfigurowalny FPGA. Dzięki takiemu rozwiązaniu uzyskano możliwość testowania algorytmów sterowania implementowanych zarówno w układach sekwencyjnych (mikrokontrolery), jak również w układach programowalnych (FPGA). Zaletą urządzenia jest możliwość synergicznego podziału realizacji algorytmu pomiędzy te dwie obecnie najpowszechniej wykorzystywane architektury obliczeniowe. Opisano specjalnie zaprojektowany układ pomiarowy napięcia wyjściowego falownika. To autorskie rozwiązanie pozwala nie tylko zmniejszyć wymagania co do parametrów podzespołów analogowych użytych do budowy toru pomiarowego, ale również w znaczący sposób odciążyć jednostkę obliczeniową układu sterującego. W artykule omówiono przyjęte założenia projektowe oraz algorytmy działania urządzenia. Zamieszczono również wybrane przebiegi w charakterystycznych stanach pracy układu.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 2, 99; 179-183
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimizing data transmission in communication systems which use magnetic couplings
Optymalizacja transmisji danych w systemach łączności wykorzystujących „sprzężenia magnetyczne”
Autorzy:
Jackiewicz, T.
Nowak, R.
Wiśniewski, G.
Powiązania:
https://bibliotekanauki.pl/articles/1361932.pdf
Data publikacji:
2015
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
optymalizacja transmisji danych
sprzężenia magnetyczne
propagacja fal elektromagnetycznych
propagacja sygnału w szybie kopalnianym
górniczy system łączności
optimizing data transmission
magnetic couplings
propagation of electromagnetic waves
signal propagation in a shaft
mining communication system
Opis:
Communication systems which make use of magnetic couplings are systems in which the transformation of signals is conducted through induction elements. These elements transfer and receive energy from the transportation unit. A good example of such a solution is a shaft communication and signal system which sends a transmission signal through ferromagnetic couplers by means of head ropes or balancing ropes. This type of communication has, undoubtedly, some advantages, such as high reliability and uncomplicated exploitation. Yet, there are some limitations related to the employed bandwidth. The article discusses important issues related to shaft communication and presents methods which allow to make maximum use of available transmission channels.
Mianem łączności wykorzystującej sprzężenia magnetyczne przyjęto nazywać systemy, w których transformacja sygnału odbywa się poprzez elementy indukcyjne, które przekazują i odbierają energię z ośrodka transportującego. Dobrym przykładem takiego rozwiązania jest system łączności i sygnalizacji szybowej, który poprzez sprzęgacze ferromagnetyczne przesyła za pomocą lin nośnych bądź wyrównawczych sygnał transmisyjny. Tego typu łączność oprócz swych niewątpliwych zalet, jakimi są duża niezawodność i prostota eksploatacji, posiada również swoje ograniczenia związane z zastosowanym pasmem przenoszenia. W artykule przedstawione zostaną rozważania i pokazane metody pozwalające na maksymalne wykorzystanie dostępnych kanałów transmisyjnych.
Źródło:
Mining – Informatics, Automation and Electrical Engineering; 2015, 53, 3; 25-30
2450-7326
2449-6421
Pojawia się w:
Mining – Informatics, Automation and Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cechy morfologiczne w fazie wegetatywnej androgenicznych linii marchwi pokolenia R1
Morphological traits of R1 androgenic carrot plants at vegetative stage
Autorzy:
Kozik, E.U.
Nowak, R.
Nowakowska, M.
Powiązania:
https://bibliotekanauki.pl/articles/796608.pdf
Data publikacji:
2004
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Opis:
Zróżnicowanie między androgenicznymi liniami R₁ oraz ich węwnątrzliniowę wyrównanie pod względem cech morfologicznych w fazie wegetatywnej oceniono w doświadczeniu założonym na początku maja w 2002 roku na polu doświadczalnym Instytutu Warzywnictwa. Obiektem badań były rośliny pokolenia R₁ pochodzące z trzech odmian donorowych (55, 62, 67) i reprezentowane odpowiednio przez 4, 8 i 3 linie. Rośliny z odmiany 62 pochodziły z różnych zarodków (z wyjątkiem 2 linii), natomiast z odmian 55 i 67 z tego samego zarodka. W czasie wegetacji dokonano obserwacji najważniejszych cech morfologicznych liści (długość i szerokość, długość ogonka liściowego, wrębność blaszki liściowej) i korzeni (masa, długość, szerokość, kształt ramion, głowy i zakończenia oraz kolor i gładkość skórki). Stwierdzono istotny wpływ odmiany donorowej na większość cech morfologicznych liścia i korzenia. Linie pochodzące z różnych odmian donorowych nie różniły się istotnie długością ogonka liściowego i szerokością liścia oraz długością, szerokością i masą korzenia. Cechy morfologiczne liścia w mniejszym stopniu niż korzenia różnicowały między sobą linie pochodzące z różnych odmian donorowych. Największe zróżnicowanie obserwowano pomiędzy liniami z odmiany 62, co mogło być spowodowane pochodzeniem tych linii z różnych zarodków. Natomiast niewielkie różnice wystąpiły między liniami z odmian 55 i 67. Mogło to wynikać z faktu, że linie zarówno w obrębie odmiany 55, jak i 67 pochodziły z tych samych zarodków. Niskie współczynniki zmienności u wszystkich badanych linii dla wszystkich cech (z wyjątkiem masy korzenia) świadczą o dużym wewnętrznym wyrównaniu badanych populacji.
Phenotypic variation of androgenic lines of R₁ population of carrot at vegetative phase was conducted in 2002 at the Research Institute of Vegetable Crops in Skierniewice. Plants of R₁ generation originating from 3 donor varieties (No. 55, 62, 67) were represented by 4, 8 and 3 lines, respectively. Plants of variety 62 were obtained initially from different embryos (excluding 2 lines), from two others they were developed within the same embryo. Several morphological traits of leaf (length and width, petiole length, leaf division) and root (weight, length and width, smoothness, shape of crown, arms and root, tip, cortex color) were established. There was a significant influence of the donor variety in most of the morphological features. Differences in petiole length, leaf width and differences in length, width and root weight between lines obtained from different donor varieties were insignificant. Leaf morphological traits rather than root characteristics differentiated lines within the same donor variety. The largest variation was recorded among lines of the variety 62, which could resulted from the fact that almost all of them originated from different embryos. On the other hand, low diversity observed among lines from the other two varieties 55 and 67, might resulted from the same embryos from which they were developed. Low values of the variation coefficient for all traits (except root weight) reflect high uniformity of each tested line.
Źródło:
Zeszyty Problemowe Postępów Nauk Rolniczych; 2004, 497, 2
0084-5477
Pojawia się w:
Zeszyty Problemowe Postępów Nauk Rolniczych
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies