Wyszukujesz frazę "overvoltage" wg kryterium: Temat


Wyświetlanie 1-14 z 14
Tytuł:
Transients under energizing multiple power filter circuits
Autorzy:
Warecki, J.
Gajdzica, M.
Powiązania:
https://bibliotekanauki.pl/articles/97327.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
capacitor
reactor
harmonic filter
C–type filter
Static Var Compensator
transient overcurrent
transient overvoltage
dynamic overcurrent
dynamic overvoltage
switching transients
Opis:
The practice of operating reactive power compensation systems involving passive multiple filter circuits (FC) configured by single–tuned filters has shown, that it’s energizing can cause damage of the filter components. Impact of feasible FC configurations, including FC with a C–type filter, on switching overvoltages and overcurrents under the harmonic filters energizing were analyzed. Influence of the filters tuning on transient behavior has been shown. The transient analysis has been carried out by simulating of the FC within Matlab/Simulink software.
Źródło:
Computer Applications in Electrical Engineering; 2016, 14; 89-100
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling transients in MV resonantly grounded industrial grid during single line to ground faults
Autorzy:
Warecki, Jurij
Gajdzica, Michał
Powiązania:
https://bibliotekanauki.pl/articles/377060.pdf
Data publikacji:
2019
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
electrical grid
grounding methods
transients overvoltage
transient intermittent faults
Opis:
Medium voltage distribution power grids mostly operate with ungrounded neutral points of transformer. The philosophy about these power supply systems based on the assumption that the electrical grid is more reliable. However the practice of operation showed that currents of single phase or multiple faults to ground depend mostly on the earth capacitances of cables connected to power grid and configuration and structure in relation to the main substation buses. Moreover, this kind of arcing ground faults on the ungrounded system causes transient overvoltages several times than nominal value. In the consequence, it may be dangerous for the electrical devices connected to the power system. The article focuses on the transient impact the equipment insulation due to faults in the middle voltage industrial grid with adjustable speed drives. The examination results of transient voltages across the system was presented. The Matlab/ Simulink Software was used to modeling system behavior during intermittent faults.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2019, 98; 65-75
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modifying the Transient Overvoltages in Mixed Power Networks by Inserting Cable Sections
Autorzy:
Saied, M. M.
Powiązania:
https://bibliotekanauki.pl/articles/262837.pdf
Data publikacji:
2015
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
cable
overvoltage
transformer
veutral treatment
transient model
lightning
mixed power networks
Opis:
The paper deals with the analysis of the electromagnetic transients in mixed power net-works. Special emphasis is made on assessing the effectiveness of using cable sections in reducing the transients in the power network components such as transformer substations. A distributed parameter modeling of the overhead lines, underground cables and transformer windings is applied in the Laplace domain. The simulation can handle the different time waveforms of the sources initiating the transients, the lengths of the cable sections as well as the transformers’ neutral treatment. The direct analytical s-domain solution is numerically inverted in order to get the corresponding time domain results. The affecting parameters such as the line and cable surge impedances, the length of the cable section (or its time delay) and the transformer data, are investigated. A case involving multiple-pulse lightning surges is also addressed. The results of four case studies of known solutions are presented in order to validate the developed mathematical model and computer program.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2015, 18, 1; 7-14
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Vacuum circuit breaker switching in medium voltage networks with photovoltaic panels at low voltage side working as a supply source
Operacje łączeniowe wyłącznikiem próżniowym w sieciach średniego napięcia z uwzględnieniem paneli fotowoltaicznych pracujących po stronie niskiego napięcia jako źródło zasilania
Autorzy:
Kuczek, T.
Florkowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/268833.pdf
Data publikacji:
2012
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
panel fotowoltaiczny
wyłącznik próżniowy
przepięcia
PV cell
vacuum circuit breaker
overvoltage
Opis:
Breaking of inductive currents with use of vacuum circuit breaker is related to a problem of current chopping before its natural zero crossing. Due to the energy trapped in oscillatory circuit consisting of transformer's inductance and capacitance, the voltage across circuit breaker contacts starts to oscillate. Breaking of dielectric withstand can lead to multiple arc re-ignitions, which can result in generation of waveforms with high steepness and overvoltage peak values. In the present article, the principle of those phenomena was explained. Simulation results of circuit breakers opening operation in medium voltage network consisting of transformer with photovoltaic panels connected at low voltage side was also presented.
Wyłączniki próżniowe stosowane w elektroenergetyce średnich napięć charakteryzują się efektem tzw. ucięcia prądu przed jego naturalnym przejściem przez zero. Z powodu energii zmagazynowanej w indukcyjności oraz pojemności transformatora, podczas operacji otwierania napięcie powrotne pomiędzy zaciskami wyłącznika zaczyna oscylować. W momencie przekroczenia wytrzymałości dielektrycznej pomiędzy zaciskami, następuje ponowny zapłon łuku elektrycznego. Zjawisko to może doprowadzić to powstania przepięć o wysokiej stromości oraz wartościach szczytowych. W pracy zaprezentowano wyniki symulacji procesu otwierania wyłącznika próżniowego w sieci z transformatorem zasilanym ze strony niskiego napięcia poprzez panele fotowoltaiczne.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2012, 31; 85-88
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of transient overvoltages in high voltage gas insulated substations
Analiza przepięć szybkozmiennych w stacjach wysokiego napięcia izolowanych gazem SF6
Autorzy:
Kuczek, T.
Florkowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/266478.pdf
Data publikacji:
2011
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
odłącznik
operacje łączeniowe
przepięcia
stacja izolowana gazem SF6
switching
transient overvoltage
GIS
disconnector
Opis:
Gas Insulated Substations (GIS) are broadly used for transmission and distribution of electric power. Due to the interactions with a network and various environmental phenomena like lightning the GIS are subjected to the very fast transients (VFT). Such VFT can be also created within GIS mainly by the disconnector operations. Paper will present an approach towards modeling of transient phenomena in GIS. The equivalent parameters along with basic models considered in substation and high voltage network modeling will be described. The difference between low and high frequency modeling will be highlighted. The simulation of transients in exemplary high voltage substation will be shown.
Stacje izolowane gazem SF6 (GIS) są szeroko wykorzystywane w elektroenergetycznych systemach przesyłowych i dystrybucyjnych. W wyniku zjawisk przejściowych takich jak operacje łączeniowe oraz wyładowania atmosferyczne, stacje GIS narażone są na występowanie przepięć bardzo szybko zmiennych, tzw. Very Fast Transients (VFT). Przepięcia te mogą być również efektem operacji łączeniowych dokonywanych odłącznikiem. Artykuł przedstawi zasady modelowania zjawisk przejściowych w stacjach GIS. W pracy zostanie ponadto pokazana przykładowa analiza przepięć generowanych poprzez operowanie odłącznikiem w stacji GIS.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2011, 30; 77-80
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transients impact on power filter circuit sizing
Autorzy:
Warecki, J.
Gajdzica, M.
Powiązania:
https://bibliotekanauki.pl/articles/97523.pdf
Data publikacji:
2015
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
capacitor
reactor
harmonic filter
transient and dynamic overvoltage
transient and dynamic overcurrent
equipment ratings
Opis:
The practice of operating multiple single-tuned filters in AC electrical arc furnace power supply systems has shown, that frequent energizing unloaded furnace transformer can cause damage of the filters. To examination of supply and filter system configuration impact on switching transient and dynamic overvoltages and overcurrents, an example of 50 MVA arc furnace unit was chosen. The transient analysis has been carried out by simulating within Matlab/Simulink Software. Using ANSI/IEEE Standards paper focuses on the selections of ratings for capacitors and air-core reactors used in multiple single-tuned harmonic filters configurations. Comparison of filter reactor and capacitor bank design based on steady state operation and transformer energizing was shown.
Źródło:
Computer Applications in Electrical Engineering; 2015, 13; 111-119
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of transients in multiple power filter circuit comprising C-type filter
Autorzy:
Warecki, J.
Gajdzica, M.
Powiązania:
https://bibliotekanauki.pl/articles/377600.pdf
Data publikacji:
2018
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
capacitor
reactor
C–type filter
single-tuned passive filter
switching transient
transient overvoltage
transient overcurrent
Opis:
Passive filters are widely used to mitigate the effect of load harmonics on the supply power grid. Topology selection of the filters is based on the frequency bandwidth to be suppressed. Filter topologies comprising single-tuned filters and damped filters are the most popular in industrial power system applications. The article focuses on the influence of the damped C-type 2nd harmonic filter on the transients behavior under arc transformer energization in the arc furnace power supply system compensated by SVC. The examination results of transient currents and voltages across capacitors and reactors of the 3rd and 5th passive filters are compared for two topologies of the SVC filter circuits: with and without C-type filter. The Matlab/Simulink Software was used to modeling filter behavior during unload transformer switching-on.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2018, 95; 105-115
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
On interaction between circuit-breaker and network at small inductive currents switching-offs
O wzajemnym oddziaływaniu wyłącznika i sieci podczas wyłączeń małych prądów indukcyjnych
Autorzy:
Lazimov, T.
Saafan, E.
Powiązania:
https://bibliotekanauki.pl/articles/410577.pdf
Data publikacji:
2011
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
SF6 and vacuum circuit-breakers
dielectric strength restoration
small inductive currents
overvoltage
recovery voltage
Opis:
Results of an investigation of interaction between circuit-breaker against its dielectric strength restoration law and parameters such as chop current and operation time (all conditioned by the circuit-breaker type and arc quenching medium) at small inductive currents' switch-offs are presented in this article. The results include curves of transitional voltages at switching under consideration and also conclusions on dependence of overvoltages and recovery voltages ratios on re-ignitions in inter-contact space. The results concerning investigation of stability are also presented. The analyzed methods were investigated from the point of view of stability in wide range of simulation parameters.
W artykule przedstawiono rezultaty badania wzajemnego powiązania rodzaju wyłącznika oraz prawa odbudowy wytrzymałości dielektrycznej i jego parametrów determinowanych rodzajem wyłącznika oraz zastosowanym medium gaszenia łuku), takich jak prąd ucięcia oraz czas wyłączenia podczas wyłączania małych prądów indukcyjnych. Badania dotyczyły określania napięć przejściowych podczas rozważnych operacji łączeniowych oraz zależności przepięć i napięć powrotu na ponowne zapłony w przestrzeni między biegunami wyłącznika. Przedstawiono również rezultaty badań stabilności obliczeń, przeprowadzonych w szerokim zakresie parametrów symulacji.
Źródło:
Present Problems of Power System Control; 2011, 1; 29-37
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Overvoltage protection of PVmicroinstallations–regulatory requirements and simulation model
Zabezpieczenie nadnapięciowe mikroinstalacji PV–wymagania i model symulacyjny
Autorzy:
Janiga, Klara
Powiązania:
https://bibliotekanauki.pl/articles/2174703.pdf
Data publikacji:
2021
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
overvoltage protection
distributed power generation
photovoltaic systems
power distribution line
zabezpieczenie nadnapięciowe
rozproszona generacja
systemy fotowoltaiczne
elektroenergetyczne sieci niskiego napięcia
Opis:
In low-voltage power networks with a large share of distributed energy sources, the phenomenon of overvoltage is increasingly observed. Although it may be desirable to raise the voltage value downstream of the network, in some cases the upper allowable voltage limit is exceeded.The method of eliminating voltage rises commonly used in the Polish power system is the installation of overvoltage protections, disconnecting the source from the grid. Such action reduces the profitability of prosumer installations, discouraging future potential investors. It turns out, however, that this is not the only disadvantage of such a solution. Sudden and uncoordinated disconnections and reconnections of more energy sources cause abrupt voltage changes that negatively affect the voltage conditions in the network.The aim of the paper is to present the operating algorithms of a standard overvoltage relay used in inverters of photovoltaic microinstallations. These algorithms –described in standards and national regulations –were tested in a typical inverter used in public low-voltage networks and implemented in the created simulation model of the relay. The described tests will be used for further work to demonstrate the need to coordinate the operation of overvoltage protections or replace them with other measures to improve voltage conditionsin the grid with high share of photovoltaic sources.
W sieciach elektroenergetycznych niskiego napięcia z dużym udziałem rozproszonych źródeł energii coraz częściej obserwuje się zjawisko podskoku napięcia. Choć samo podniesienie wartości napięcia w głębi sieci może być pożądane, to jednak w niektórych przypadkach dochodzi do przekroczenia górnej dopuszczalnej granicy napięciowej. Powszechnie stosowanym w polskim systemie elektroenergetycznym sposobem eliminacji podskoków napięcia jest instalowanie zabezpieczeń nadnapięciowych, wyłączających źródło z sieci. Działanie takie obniża opłacalność instalacji prosumenckich, zniechęcając przyszłych potencjalnych inwestorów. Okazuje się jednak, że nie jest to jedyna wada takiego rozwiązania. Nagłe i nieskoordynowane wyłączenia i ponowne załączenia większej liczby źródeł energii powodują skokowe zmiany napięcia, które negatywnie wpływają na warunki napięciowe w sieci. Celem artykułu jest zaprezentowanie algorytmów działania standardowego przekaźnika nadnapięciowego stosowanegow falownikach mikroinstalacji fotowoltaicznych. Algorytmy te – opisane w normach i krajowych przepisach –przetestowano w typowym falowniku stosowanym w publicznych sieciach niskiego napięcia oraz zaimplementowano w utworzonym modelu symulacyjnym przekaźnika. Opisane badania posłużą do dalszych prac, mających wykazać konieczność koordynacji działania zabezpieczeń nadnapięciowych lub zastąpienia ich innymi środkami poprawy warunków napięciowych w sieci z dużym nasyceniem fotowoltaiką.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2021, 11, 2; 40--43
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparision of Buck-Converter parameters quality depending on coil selection
Autorzy:
Pragłowska-Ryłko, N.
Powiązania:
https://bibliotekanauki.pl/articles/105698.pdf
Data publikacji:
2015
Wydawca:
Centrum Badań i Innowacji Pro-Akademia
Tematy:
Buck-Converter
step-down converter
DC-DC power converter
overvoltage
coil selection
przetwornica Buck
step-down konwerter
przekształtniki DC/DC
przepięcie
Opis:
Buck-Converters belong to DC/DC converters group. One of the main problems during the design stage of DC/DC converter is the proper component selection. The aim of this article is to describe selection of the optimal inductor for the Buck-Converter, enabling to minimize the device output overvoltage, while getting possibly high device efficiency. In order to verify the quality parameters, author made an efficiency comparison of the buck converter, depending on used inductor. Conclusions from this paper allow for optimal selection of coils for the Buck-Converter depending on given criteria.
Źródło:
Acta Innovations; 2015, 17; 22-29
2300-5599
Pojawia się w:
Acta Innovations
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Main aspects influencing the evaluation of atmospheric overvoltages in high-voltage networks
Autorzy:
Borecki, Michał
Ciuba, Maciej
Kharchenko, Yevhen
Khanas, Yuriy
Powiązania:
https://bibliotekanauki.pl/articles/2173536.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
overvoltage protection
high voltage networks
reliability of power grids
risk analysis
ochrona przed wysokim napięciem
sieć wysokiego napięcia
niezawodność sieci elektroenergetycznych
ocena ryzyka
Opis:
The effectiveness of lightning protection on the power and distribution grid is a significant factor, which influences the power distribution reliability and the failure rate of system elements. As part of this article, a mathematical model will be presented, taking into account selected parameters that affect the assessment of the lightning hazard of an overhead line. The proposed model will consider the location of the object near the line and the adjustment of line conductor overhangs. Moreover, the mentioned mathematical model allows for analyzing the impact of considered parameters on the protection level of the power system, and transient overvoltages that occur in this system. The article contains also a detailed description of an effective and fast method to assess the lightning discharge impact on the power system with insufficient data. The introduced model was tested to verify the correctness of its operation by comparison of calculation results and functional data. High convergence of calculated and functional data and uncomplicated model structure ensure a wide range of applications for the proposed solution to easily prevent emergency situations in the power system. Furthermore, the described model gives the opportunity to assess the reduction of the range of selectivity zone associated with the power line, in conjunction with the impact of constructional peculiarities and a near object.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 1; art. no. e135838
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Main aspects influencing the evaluation of atmospheric overvoltages in high-voltage networks
Autorzy:
Borecki, Michał
Ciuba, Maciej
Kharchenko, Yevhen
Khanas, Yuriy
Powiązania:
https://bibliotekanauki.pl/articles/2090728.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
overvoltage protection
high voltage networks
reliability of power grids
risk analysis
ochrona przed wysokim napięciem
sieć wysokiego napięcia
niezawodność sieci elektroenergetycznych
ocena ryzyka
Opis:
The effectiveness of lightning protection on the power and distribution grid is a significant factor, which influences the power distribution reliability and the failure rate of system elements. As part of this article, a mathematical model will be presented, taking into account selected parameters that affect the assessment of the lightning hazard of an overhead line. The proposed model will consider the location of the object near the line and the adjustment of line conductor overhangs. Moreover, the mentioned mathematical model allows for analyzing the impact of considered parameters on the protection level of the power system, and transient overvoltages that occur in this system. The article contains also a detailed description of an effective and fast method to assess the lightning discharge impact on the power system with insufficient data. The introduced model was tested to verify the correctness of its operation by comparison of calculation results and functional data. High convergence of calculated and functional data and uncomplicated model structure ensure a wide range of applications for the proposed solution to easily prevent emergency situations in the power system. Furthermore, the described model gives the opportunity to assess the reduction of the range of selectivity zone associated with the power line, in conjunction with the impact of constructional peculiarities and a near object.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 1; e135838, 1--8
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Electric networks of energy-intensive enterprises: the protection of 6–10 kV lines and access ways from overvoltage
Sieci elektryczne przedsiębiorstw energochłonnych: ochrona linii 6–10 kV i miejsc dostępu przed przepięciami
Autorzy:
Dmitrichenko, Viktor I.
Abdimuratov, Zhubanyshbay S.
Kazanina, Irina V.
Omirzakov, Nagym T.
Zhagyparov, Yerkebulan N.
Powiązania:
https://bibliotekanauki.pl/articles/2127482.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
electric networks
energy-intensive enterprises
overvoltage
power lines
protection of electric networks
energy security
sieci elektryczne
przedsiębiorstwa energochłonne
przepięcia
linie elektroenergetyczne
ochrona sieci elektrycznych
bezpieczeństwo energetyczne
Opis:
The purpose of this research work is to study the issues of the protection of 6–10 kV lines and access ways overvoltage in the electrical networks of modern enterprises of high-energy intensity, as well as the search for real technical opportunities to improve the protection of power lines directly in conditions of their operation. The methodology of this scientific research is based on a combination of methods of system analysis of the principles of the functioning of electric networks of energy-intensive enterprises with an analytical study of the fundamental aspects of ensuring the protection of 6 to 10 kV lines and access ways from overvoltage. The results of the conducted scientific research indicate the relevance of the issues of ensuring the protection of lines and electrical networks of energy-intensive enterprises from overvoltage and the need to develop special technical devices to ensure the proper level of such protection in real conditions. The results and conclusions of this research work are of significant importance for developers and designers of electric networks of enterprises with increased energy capacity, as well as for employees of various power supply systems who, by their occupation, face the tasks of servicing electric networks, which include lines and access ways with specified operating voltage parameters and ensuring the proper level of safety and practical use of these electric networks of energy-intensive enterprises.
Celem pracy badawczej jest zbadanie problematyki ochrony linii 6–10 kV i przepięć w miejscach dostępu w sieciach elektroenergetycznych nowoczesnych przedsiębiorstw o dużej energochłonności, a także poszukiwanie realnych technicznych możliwości poprawy ochrony linii elektroenergetycznych bezpośrednio w warunkach ich eksploatacji. Metodologia niniejszych badań naukowych opiera się na połączeniu metod analizy systemowej zasad funkcjonowania sieci elektroenergetycznych przedsiębiorstw energochłonnych z analitycznym badaniem podstawowych aspektów zapewnienia ochrony linii od 6 do 10 kV oraz miejsc dostępu do nich od przepięcia. Wyniki przeprowadzonych badań wskazują na istotność zagadnień zapewnienia ochrony linii i sieci elektrycznych przedsiębiorstw energochłonnych przed przepięciami oraz konieczność opracowania specjalnych urządzeń technicznych zapewniających właściwy poziom tej ochrony w warunkach rzeczywistych. Wyniki i wnioski z tej pracy badawczej mają istotne znaczenie dla wykonawców i projektantów sieci elektrycznych przedsiębiorstw o podwyższonej energochłonności, a także dla pracowników różnych systemów zasilania, którzy z racji wykonywanego zawodu mają do czynienia z zadaniami serwisowania sieci elektrycznych obejmujących linie o określonych parametrach pracy oraz odpowiadają za odpowiedni poziom bezpieczeństwa i praktycznego użytkowania tych sieci elektrycznych przedsiębiorstw energochłonnych.
Źródło:
Polityka Energetyczna; 2022, 25, 3; 51--66
1429-6675
Pojawia się w:
Polityka Energetyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Switching and lightning overvoltages and the required withstand voltage betweeen the open contacts of 245 KV circuit breakers
Przepięcia łączeniowe i piorunowe a wymagany poziom wytrzymałości otwartych styków wyłączników 245 KV
Autorzy:
Bandel, J.
Hejduk, A.
Dzierżyński, A.
Korycki, P.
Sibilski, H.
Powiązania:
https://bibliotekanauki.pl/articles/159303.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
high voltage circuit breakers
switching inductive and capacitive currents
switching and atmospheric overvoltage
lightning arresters
wyłączniki najwyższych napięć
łączenie prądów indukcyjnych i pojemnościowych
przepięcia łączeniowe i atmosferyczne
ogranicznik napięcia
Opis:
Przedstawiono sposób oceny wartości przepięć generowanych w sieci pomiędzy otwartymi stykami wyłącznika podczas operacji łączeniowych i wyładowań piorunowych. Wartości przepięć porównano z wartościami napięć probierczych wyłączników. Zaproponowano sposób doboru ograniczników napięcia. Wyłączanie prądów zwarciowych może powodować osłabienie izolacji komory wyłącznika zmniejszając jego wytrzymałość elektryczną i trwałość łączeniową. W energetyce zgłaszano przypadki zapłonów łuku na otwartych stykach wyłączników, tego rodzaju awarie mogą być bardzo groźne w skutkach. Problem ten dotyczy przede wszystkim wyłączników jednoprzerwowych, w których naprężenia elektryczne izolacji przerwy pomiędzy stykowej wyłącznika są bardzo duże. Z tego powodu pojawiają się postulaty zwiększenia liczby łączeń podczas badań typu wyłącznika, jakie należy wykonywać bez wymiany jakichkolwiek części komory wyłącznika, czy też napędu.
This paper deals with the surges generated in the network during switching operations and lightning surges. The level of both kinds of surge was compared with the required dielectric strength between the open contacts of 245 kV circuit breakers. Overvoltages greater than the electrical withstand voltage of the circuit breaker can cause arc ignition between the circuit breaker’s open contacts and power engineering service s have reported such cases. The results of such failures can be very serious. This is a problem especially for single-break circuit breakers, in which the stresses on the electrical insulation between the open contacts of the breaker are very high. A method for selecting lightning arresters to lower the overvoltages is proposed. The switching of short-circuit currents by a circuit breaker may cause a weakening of the circuit breaker chamber’s insulation and reduce its electrical withstand and durability.
Źródło:
Prace Instytutu Elektrotechniki; 2016, 274; 43-60
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-14 z 14

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies