Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Frequency Response Analysis" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
Impact of other windings on frequency response of power transformers
Autorzy:
Banaszak, S.
Gawrylczyk, K. M.
Powiązania:
https://bibliotekanauki.pl/articles/378065.pdf
Data publikacji:
2015
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
transformer
frequency response analysis (FRA)
modelling of windings
Opis:
The diagnostics of power transformers is a very fast developing branch. Due to increasing average age of assets and changes in asset management strategies, nowadays companies introduce asset management based on technical condition. One of important methods used for diagnostics of a transformer’s active part is Frequency Response Analysis (FRA). It allows determination of mechanical condition of windings, their displacements, deformations and electric faults, as well as some problems with internal leads and connections, core and bushings. In the FRA measurements of many power transformers there can be observed a first resonance, which position on frequency axis and damping factor seems to be similar for primary and secondary windings. The authors are going to explain this strange phenomenon, not depending on inductance of the winding being measured.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2015, 81; 31-38
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
TLM-method for Computer Modeling of Transformers’ Windings Frequency Response
Autorzy:
Banaszak, S.
Gawrylczyk, K. M.
Powiązania:
https://bibliotekanauki.pl/articles/97469.pdf
Data publikacji:
2012
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
TLM
frequency response analysis (FRA)
FRA
transformer windings
Opis:
The diagnostics of power transformers is a very fast developing branch, due to increasing average age of assets and changes in asset management strategies, nowadays companies introduce asset management based on technical condition. One of important methods used for diagnostics of a transformer’s active part is Frequency Response Analysis (FRA). It allows determination of mechanical condition of windings, their displacements, deformations and electric faults, as well as some problems with internal leads and connections, core and bushings. For the aim of windings impedance modeling the transmission-line models are applied. The idea of TLM was presented in [1]. While the length of transformer wires is comparable to wave length at high frequency, such approach is reasonable. The paper presents examples of models created for simple windings.
Źródło:
Computer Applications in Electrical Engineering; 2012, 10; 137-145
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
TLM-method for computer modeling of transformers’ windings frequency response
Autorzy:
Banaszak, S.
Gawrylczyk, K. M.
Powiązania:
https://bibliotekanauki.pl/articles/376947.pdf
Data publikacji:
2012
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
power transformers
FRA
TLM
frequency response analysis (FRA)
Opis:
The diagnostics of power transformers is a very fast developing branch, due to increasing average age of assets and changes in asset management strategies, nowadays companies introduce asset management based on technical condition. One of important methods used for diagnostics of a transformer’s active part is Frequency Response Analysis (FRA). It allows determination of mechanical condition of windings, their displacements, deformations and electric faults, as well as some problems with internal leads and connections, core and bushings. For the aim of windings impedance modeling the transmission-line models are applied. The idea of TLM was presented in [1], While the length of transformer wires is comparable to wave length at high frequency, such approach is reasonable. The paper presents examples of models created for simple windings.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2012, 69; 41-47
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
RLC-models for computer modeling of transformers’ windings frequency response
Autorzy:
Banaszak, S.
Gawrylczyk, K. M.
Powiązania:
https://bibliotekanauki.pl/articles/376937.pdf
Data publikacji:
2013
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
power transformers
FRA
frequency response analysis (FRA)
RLC models
Opis:
The diagnostics of power transformers is a very fast developing branch, due to increasing average age of assets and changes in asset management strategies, nowadays companies introduce asset management based on technical condition. One of important methods used for diagnostics of a transformer’s active part is Frequency Response Analysis (FRA). It allows determination of mechanical condition of windings, their displacements, deformations and electric faults, as well as some problems with internal leads and connections, core and bushings. For the aim of windings impedance modeling the RLC models are applied. The idea of lumped parameters models was presented in [6]. The new universal model basing on circuit solution is developed in this paper. Lumped parameters used are calculated with finite element method and Maxwell package. The examples of models created for simple windings were compared to real measurements.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2013, 73; 107-113
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Practical use of RLC-models of transformers’ windings for determination of local displacements
Autorzy:
Banaszak, S.
Gawrylczyk, K. M.
Powiązania:
https://bibliotekanauki.pl/articles/97720.pdf
Data publikacji:
2013
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
transformer’s diagnostic
frequency response analysis (FRA)
lumped parameter models
Opis:
The diagnostics of power transformers is a very fast developing branch, due to increasing average age of assets and changes in asset management strategies, nowadays companies introduce asset management based on a real technical condition. One of important methods used for diagnostics of a transformer’s active part is Frequency Response Analysis (FRA). It allows determination of mechanical condition of windings, their displacements, deformations and electric faults, as well as some problems with internal leads and connections, core and bushings. For the aim of windings impedance modeling the RLC models are applied. The idea of lumped parameters models was presented in [6]. The new universal model basing on circuit solution is developed in this paper. Lumped parameters used in calculations are obtained with finite element method and Maxwell package. The examples of models created for simple windings were compared to real measurements.
Źródło:
Computer Applications in Electrical Engineering; 2013, 11; 100-109
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of frequency response of transformer winding with axial deformations
Autorzy:
Gawrylczyk, K. M.
Banaszak, S.
Powiązania:
https://bibliotekanauki.pl/articles/140733.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
transformer
winding
frequency response analysis (FRA)
lumped parameters method
transmission line method
Opis:
One of important methods used for diagnostics of a transformer’s active part is Frequency Response Analysis (FRA). It allows to determine the mechanical condition of windings, their displacements, deformations and electric faults, as well as some problems with internal leads and connections, core and bushings. Still pending problem is interpretation of measurements results. One of approaches is application of computer modeling to simulate various failure modes and connected with them changes in FRA response. The paper presents two types of models, one based on lumped parameters with RLC elements, and one based on distributed parameters with TLM method. Both methods give similar results, comparable to real measurements of simulated coil.
Źródło:
Archives of Electrical Engineering; 2014, 63, 1; 5-17
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies