Reliability of a Collective Wastewater Treatment Plant
Autorzy:
Bugajski, P.
Chmielowski, K.
Kaczor, G.
Powiązania:
https://bibliotekanauki.pl/articles/125059.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
wastewater treatment plant
technological reliability
Weibull theory
Opis:
The paper discusses technological reliability of a collective wastewater treatment plant (WTP). The WTP capacity expressed as population equivalents (PE) was 22,500. The research was conducted in 2013 and 2014 and it involved the collection and physical and chemical analysis of 101 samples of raw and treated sewage. Reliability analysis was based on Weibull reliability theory. Reliability of retaining organic compounds defined as BOD5 was 68%, and for biogenic compounds, such as total nitrogen and total phosphorus, it was 92% and 88%, respectively.
Źródło:
Journal of Ecological Engineering; 2016, 17, 4; 143-147
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of extraneous waters on the proportion of sewage pollution indices regarding its biological treatment
Autorzy:
Kaczor, G.
Bergel, T.
Bugajski, P.
Powiązania:
https://bibliotekanauki.pl/articles/59684.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
extraneous water
proportion
sewage
pollution index
biological treatment
denitrification
dephosphatation
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2015, IV/3
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Compositional analysis of the sewage incoming to and discharged from the sewage treatment plant in Kolbuszowa Dolna
Autorzy:
Chmielowski, K.
Bugajski, P.
Kaczor, G.
Powiązania:
https://bibliotekanauki.pl/articles/123438.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
sewage biodegradation
wastewater treatment plant
sewage composition
Opis:
The paper presents the compositional analysis of sewage supplied to and discharged from the wastewater treatment plant in Kolbuszowa Dolna in the Subcarpathian region. The analysis was based on three basic indicators of sewage pollution (BOD5, CODCr, total suspended solids) and two biogenic indicators (total nitrogen and total phosphorus). The composition of sewage was studied in the years 2010–2015. Basic descriptive statistics for the values of the analyzed indicators of sewage pollution were summarized and the obtained results were interpreted. The study showed that the sewage was susceptible to biological treatment. Descriptive statistics for the relationship between the following indicators were presented: CODCr/BOD5, BOD5/Ntot, BOD5/Ptot. The collected results indicate high variability of the composition of sewage entering the studied facility. The coefficients of variation for the values of basic indicators (BOD5, CODCr, total suspended solids) in the raw sewage were similar and amounted to Wn = 0.45 while for total nitrogen it was Wn = 0.33 and for total phosphorus Wn = 0.40. The analysis of the collected material showed that sewage entering the treatment plant was readily biodegradable. On the other hand, the treated sewage was characterized by low values of the analyzed indicators, much below the permissible values provided by the water permit. The raw sewage was divided into five groups depending on the concentration of each pollution indicator. The number of raw sewage samples was determined for each group of the analyzed pollution indicator concentrations.
Źródło:
Journal of Ecological Engineering; 2016, 17, 5; 9-16
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the structure of water consumption in rural households in terms of design guidelines water and sewage systems
Autorzy:
Bergel, T.
Kaczor, G.
Bugajski, P.
Powiązania:
https://bibliotekanauki.pl/articles/100995.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
rural household
water consumption
structure of water consumption
Opis:
The aim of the paper was an analysis of the structure of tap water consumption by rural households considering the use of its results for designing the elements of water supply and sewer systems. The analysis of this structure was based on direct measurements of water consumption conducted in 2011-2014 in 30 households located in Przeginia Duchowna village (Czernichów commune, Malopolskie province). Double measurement of water consumption (water supply connection or water draw off point outside a residential building) enabled the separation water consumption for household and additional purposes from the total water consumption per household. Analysis of the collected data revealed considerable disproportions between the real water consumption and stated in the design guidelines. Calculated on the basis of the study, averaging 85.6 dm3 I-1·d-1, accounted for only 57% of the value of 150 dm3 I-1·d-1 most commonly used in design. Because of the possible determining the water consumption structure it was demonstrated, that the divergences concerned also the volume of domestic sewage discharged from rural households. Obtained results revealed also that application of the principle, where the volume of sewage equals the volume of water consumption by rural households, for designing sewer systems is usually incorrect. In the analyzed household in fact, only 83.1% of the volume of waste water was discharged in the form of waste water to the sewage system. The remainder was called. non-returnable water consumption for additional purposes.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2016, IV/4; 1899-1910
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Struktura zużycia zimnej i ciepłej wody w gospodarstwie jednorodzinnym
Structure of expenditure of cold and hot water in one-family apartment
Autorzy:
Bugajski, P.
Kaczor, G.
Powiązania:
https://bibliotekanauki.pl/articles/59652.pdf
Data publikacji:
2005
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
gospodarstwa domowe
woda ciepla
woda zimna
zuzycie wody
struktura zuzycia
Opis:
W artykule przedstawiono strukturę zużycia zimnej i ciepłej wody w lokalu zamieszkanym przez 3-osobową rodzinę. W omawianym mieszkaniu zainstalowano 2 wodomierze wody zimnej i ciepłej w łazience oraz 2 wodomierze wody zimnej i ciepłej w kuchni. Zimna i ciepła woda w kuchni zużywana jest w trakcie przygotowywania posiłków oraz zmywania naczyń, natomiast w łazience woda zimna zużywana jest w celu spłukiwania miski ustępowej oraz na pranie, natomiast woda ciepła zużywana jest w celu utrzymania higieny osobistej mieszkańców. W kuchni występuje jeden punkt czerpalny wody zimnej i ciepłej (bateria nad zlewozmywakiem), natomiast w łazience cztery punkty czerpalne wody zimnej oraz dwa punkty czerpalne wody ciepłej. Celem pracy jest określenie struktury zużycia wody zimnej i ciepłej w wybranym gospodarstwie domowym. Szczegółowe cele to określenie faktycznej objętości wody zimnej, a także ciepłej zużywanej w łazience oraz w kuchni w badanym okresie. Woda zimna dostarczana jest z sieci wodociągowej, natomiast woda ciepła z elektrociepłowni MPEC S.A. w Krakowie. W roku badawczym 2004 mieszkańcy zużyli łącznie 96,08 m3 wody. Średnie zużycie jednostkowe wyniosło 101,0 dm3*M-1*d-1. Analiza zużycia wody w poszczególnych miesiącach roku 2004 wykazała, że najwyższe pobory wody wystąpiły w sierpniu, natomiast najniższe w kwietniu. Największa nierównomierność dobowa zużycia wody wystąpiła w maju (Ndmax = 2,4), a najmniejsza we wrześniu i grudniu (Ndmax = 1,4). W badanym okresie zużycie wody ciepłej stanowiło 38% całości zużywanej wody. Średnio w badanym okresie zużycie wody ciepłej wyniosło 38,6 dm3*M-1*d-1, natomiast wody zimnej 62,4 dm3*M-1*d-1. Przeprowadzone badania i wynikające z nich wnioski mogą posłużyć do nowelizacji obowiązujących wytycznych w zakresie zużycia wody oraz objętości wytwarzanych ścieków, które w świetle najnowszych doniesień literaturowych są zdecydowanie zawyżone.
The article presents a structure consumption cold and hot water in apartment with family with 3 people. In analyze apartment install 2 water meters cold and hot water in bathroom and 2 water meters cold and hot water in kitchen. Cold and hot water in kitchen consumption is to prepare meal and to wash dishes. Cold water in bathroom consumption is to rinse off toilet bowl and laundry. Hot water in bathroom consumption is for people in target to keep personal hygiene. In kitchen is one point to draw cold and hot water (sink). In bathroom are for points to draw cold water and two points to draw hot water. The aim of this paper is to describe structure of consumption cold and hot water in to discuss apartment. The detail aims is describe actual parts cold water consumption in bathroom and kitchen and actual parts hot water consumption in bathroom and kitchen. Cold water is deliver with water supply, however hot water with heat and power plant MPEC S.A. in Krakow. In 2004 persons consumed 96,08 m3 water. Medium consumption on one person was 101,0 dm3∙M-1∙d1. Analysis consumption in months in 2004 year showed the highest consumption was in august, but the slowest in april. The highest irregular day consumption water was in may (Ndmax = 2,4), the slowest in september and december (Ndmax = 1,4). In analysis period consumption hot water was 38% all water. In analysis period medium of consumption hot water was 38,6 dm3∙M-1∙d-1, however cold water 62,4 dm3∙M-1∙d-1. In consequently to study and them interpretation can to expect to update current regulation in extent of consumption of water and capacity of production sewage.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2005, 2
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ wybranych czynników na temperaturę ścieków w bioreaktorze przepływowym
Influence of chosen factors on sewage temperature in the flow of biological reactor
Autorzy:
Bugajski, P.
Kaczor, G.
Powiązania:
https://bibliotekanauki.pl/articles/60736.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
kanalizacja
scieki doplywajace
temperatura powietrza
reaktory biologiczne
temperatura sciekow
Opis:
Badania miały na celu określenie wpływu temperatury ścieków dopływają-cych z kanalizacji oraz wpływu temperatury powietrza atmosferycznego na tempe-raturę ścieków w otwartym - przepływowym reaktorze biologicznym. Do badań wytypowano mały system kanalizacyjny, wraz z oczyszczalnią ścieków, zakwalifi-kowany do grupy systemów do 2000 RLM, zlokalizowany na terenie gminy wiej-skiej w województwie małopolskim. W okresie badań do analizowanego systemu kanalizacyjnego odprowadzano ścieki z 250 budynków. Średni dobowy przepływ ścieków w badanym roku wynosił 115 m3•d-1. Badania objęły okres 12 miesięcy od 1 stycznia do 31 grudnia 2010 roku. Aby wykazać wpływ omawia-nych czynników na temperaturę ścieków w bioreaktorze posłużono się analizą re-gresji wielokrotnej, która pozwala liczbowo określić wpływ poszczególnych zmiennych niezależnych, którymi są temperatura ścieków w kanalizacji oraz tem-peratura powietrza atmosferycznego na zmienną zależną, którą jest temperatura ścieków w bioreaktorze. W rocznym okresie badań stwierdzono dużą zmienność średniej dobowej temperatury ścieków odpływających z kanalizacji oraz średniej dobowej temperatury powietrza atmosferycznego. Średnia dobowa temperatura ścieków dopływających do reaktora wyniosła 11,0oC. Najniższa odnotowana tem-peratura ścieków dopływających wynosiła 4,9 oC, natomiast najwyższa 20,5oC. W badanym roku średnia dobowa temperatura powietrza atmosferycznego wyniosła 8,3oC. Na podstawie wyników korelacji cząstkowej stwierdzono, iż większy wpływ na temperaturę ścieków w bioreaktorze miała temperatura ścieków dopływających z kanalizacji niż temperatura powietrza. Współczynnik korelacji cząstkowej dla temperatury ścieków surowych wyniósł Rc=0,95, natomiast dla temperatury powietrza atmosferycznego Rc=0,73. Średnia dobowa temperatura ścieków w bioreaktorze w okresie rocznych pomiarów wyniosła 12,2oC, natomiast amplituda jej zmian wahała się od 5,3 do 20,5oC. W badanym okresie wynoszącym 365 dni tylko w 15 przypadkach stwierdzono występowanie temperatury ścieków w bioreaktorze wyższej od 18oC, czyli temperatury określonej w literaturze jako optymalnej dla prawidłowego metabolizmu mikroorganizmów osadu czynnego. Przedstawione wyniki badań, dotyczące zakresu zmian temperatury ścieków w małym wiejskim systemie kanalizacyjnym, zaliczanym do grupy do 2000 RLM, odbiegają od charakterystyki temperatury, opisywanej w literaturze, dotyczącej du-żych miejskich systemów odprowadzania i unieszkodliwia ścieków zaliczanych do grupy obiektów powyżej 100 000 RLM.
The aim of the research was defining influence temperature of the sewage flow from sewage system and the temperature of the atmospheric air on temperature sewage in open biological reactor of flow. To research one chose the small sewerage system with the sewage treatment plant serving to 2000 PE (Population Equivalents) situated on the village-commune in the malopolska voivodeship. Within a period of research the sewerage accompanied sewage from 250 buildings. The average flow of sewage in the investigated year was from 110 to 120 m3·d-1. The research embraced the period of 12 months from 1 January to 31 December the year 2010. To describe this relationship used of the multiple regression of analysis. In the period of research ascertained the large variability of the average temperature of sewage flow from sewage system and large variability of average of the temperature of the atmospheric air. The average of mean daily temperature of sewage flow was 11.0 oC. The lowest of temperature of sewage flow was 4.9 oC and the highest was 20.5 oC. In the investigated year of mean daily of the temperature of the atmospheric air was 8.3 oC. The research of concerning of multiple regression of analysis proved, that the greater influence on the temperature of sewage in biological reactor has the temperature of sewage flow from sewage system. The coefficient of correlation for these variable carried Rc=0.95. The .instead smaller relationship was noted of influence of the temperature of the atmospheric air on the temperature of sewage in biological reactor. The coefficient of correlation for these dependence carried Rc=0.73. The average of mean daily temperature of sewage in biological reactor in 2010 year was 12.2 oC, and the amplitude of changes was from 5.3 to 20.5 oC. In the investigated period of 365 days only in 15 days mean daily temperature in biological reactor was above 18 oC. The described result of research of concerning sizes and the range of changes of the temperature of sewage in small villages sewage system in the group to 2000 PE can differ from the information in the literature concerning large municipal sewage systems above 100 000 PE.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2012, 2/I
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of sewage susceptibility to biodegradation on an example of sewage treatment plant in Wodzisław Śląski
Autorzy:
Chmielowski, K.
Wąsik, E.
Operacz, A.
Bugajski, P.
Kaczor, G.
Jurik, L.
Powiązania:
https://bibliotekanauki.pl/articles/101267.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
sewage biodegradation
sewage composition
sewage treatment plant
Opis:
The paper presents an analysis of sewage susceptibility to biodegradation on an example of sewage treatment plant in Wodzisław Śląski in the Śląskie province. For this purpose, dependencies between selected indices of domestic sewage pollution were applied. Descriptive statistics of the respective indices rations COD/BOD5 , BOD5 /TN, BOD5 /TPwere presented. Moreover, an analysis was conducted on the composition of raw sewage flowing into the treatment plant, pre-treated sewage and sewage leaving the studied treatment plant. The analysis was carried out on the basis of three basic indices of sewage pollution (BOD5 , COD and total suspended solids) and two biogenic indices (total nitrogen and total phosphorus). Tests on the sewage composition were conducted in the years 2010-2015. Basic descriptive statistics were compiled for the values of the studied indices of sewage pollution and the obtained results were interpreted. On the basis of collected material it may be said that sewage reaching the treatment plant in Wodzisław Śląski revealed a good susceptibility to biodegradation, whereas the BOD5 /TN and BOD5 /TP ratios were below the optimum value.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2017, IV/1; 1427-1443
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ lokalizacji oczyszczalni na temperaturę dopływających do niej ścieków
Influence of treatment plant location on temperature of inflowing sewage
Autorzy:
Kaczor, G.
Bugajski, P.
Chmielowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/101199.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
oczyszczalnia ścieków
ścieki
kanalizacja
temperatura ścieków
wastewater treatment plant
wastewater
sewage system
wastewater temperature
Opis:
Celem przeprowadzonych badań było uzyskanie wiedzy, jak umiejscowienie oczyszczalni względem zlewni kanalizacyjnej wpływa na temperaturę dopływających do niej ścieków. Analizą objęto cztery systemy kanalizacyjne, różniące się długością kolektora tranzytowego pomiędzy oczyszczalnią a zabudowaniami mieszkalnymi, w których wytwarzane były ścieki bytowe. W badanych systemach kanalizacyjnych ścieki odprowadzane były do oczyszczalni o przepustowości hydraulicznej od 100 do 300 m3·d-1, charakteryzujących się liczbą RLM nie większą niż 2000. Pomiary temperatury ścieków odpływających z kanalizacji oraz powietrza atmosferycznego, w analizowanym roku 2012, prowadzono w sposób ciągły, z interwałem 1 godzinnym, za pomocą czujników rezystancyjnych połączonych z rejestratorami danych. Przeprowadzone badania wykazały, że odległość oczyszczalni od zlewni kanalizacyjnej wywiera istotny wpływ na temperaturę ścieków odpływających z sieci kanalizacyjnej. W okresie zimowym średnia dobowa temperatura ścieków odpływających z kolektorów tranzytowych o długości od 300 do 600 m była niższa nawet o blisko 3ºC, natomiast w okresie letnim aż o 8ºC, w porównaniu do kolektorów tranzytowych o długości nieprzekraczającej 10 m. Wykazano ponadto, że na temperaturę ścieków dopływających do oczyszczalni, oprócz długości kolektora tranzytowego, istotnie wpływa także natężenie przepływu ścieków. Przy wzroście natężenia odpływu ścieków z kanalizacji o 100%, ich temperatura może wzrosnąć w okresie zimowym o 1ºC, natomiast w letnim o 3ºC. W przypadku sieci kanalizacyjnych zakończonych długimi kolektorami tranzytowymi, niekorzystnemu skróceniu ulega czas trwania temperatury ścieków optymalnej w aspekcie usuwania związków biogennych, a przy tym jednocześnie wydłuża się czas trwania temperatury ścieków niekorzystnej dla ich biologicznego oczyszczania.
The aim of the research was to get the expertise, how location of wastewater treatment plant to basin of sewage system influences the temperature of inflowing wastewater. The analysis included four sewage systems, which are different for the sake of length of transit canal between treatment plant and residential buildings, in which domestic sewage was produced. In analysed systems sewage flew into the treatment plants with hydraulic capacity range from 100 to 300 m3·d-1, and with population equivalent less than 2000. Measurements of temperature of air and wastewater outflowing from sewage system, in analysed year 2012, were conducted continuously, with 1 hour interval, with use resistance sensors connected with data recorder. The research showed, that the distance of treatment plant to basin of sewage system has a significant impact on wastewater temperature outflowing from sewage system. In winter period mean daily wastewater temperature outflowing from transit manifolds with length from 300 to 600 m was lower even about 3ºC, but in summer period up to 8ºC, in comparison to transit manifolds with length less than 10 m. Moreover, it was proved that, apart from length of transit manifold, also intensity of wastewater flow has a significant impact on wastewater temperature flowing into the treatment plant. With increase of intensity of wastewater flow about 100%, its temperature can increase in winter period about 1ºC, and about 3ºC in summer period. In case of sewage systems ended with long transit manifold, the duration time of optimal sewage temperature in terms of biogenic compounds removal is unfavourable reduced, and at the same time the duration time of wastewater temperature unfavourable for its biological treatment is extended.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2016, II/2; 615-626
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Skuteczność eliminacji azotu w przydomowych oczyszczalniach z osadem czynnym
Effectiveness of elimination of nitrogen in domestic sewage treatment plants with activated sludge
Autorzy:
Bugajski, P.
Kaczor, G.
Bergel, T.
Powiązania:
https://bibliotekanauki.pl/articles/61685.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
oczyszczalnie sciekow przydomowe
osady czynne
azot ogolny
temperatura sciekow
usuwanie azotu
skutecznosc oczyszczania
Opis:
Celem badań było określenie skuteczności usuwania związków azotu w dwóch przydomowych oczyszczalniach ścieków działających w oparciu o technologię osadu czynnego. Ponadto określono wpływ temperatury ścieków w reaktorach biologicznych na skuteczność eliminacji analizowanego wskaźnika. Analizowane obiekty to oczyszczalnia ścieków Turbojet EP-2 o przepustowości projektowanej od 1,2 do 1,8 m3·d-1, oraz oczyszczalnia Turbojet EP-4 o przepustowości projektowanej 3,5÷5,0 m3·d-1. W okresie badań oba obiekty były niedociążone hydraulicznie. Na podstawie badań prowadzonych w latach 2008-2010 stwierdzono, że średnie stężenia azotu ogólnego w ściekach surowych wynosiły 82,6 mgNog·dm-3 w oczyszczalni Turbojet EP-2 oraz 102,0 mgNog·dm-3 w oczyszczalni Turbojet EP-4, natomiast średnie stężenia azotu ogólnego w ściekach oczyszczonych wynosiły 30,2 mgNog·dm-3 w oczyszczalni Turbojet EP-2 i 65,5 mgNog·dm-3 w oczyszczalni Turbojet EP-4. W okresie badań stwierdzono duże wahania stężeń azotu ogólnego w ściekach oczyszczonych, które wynosiły od 12,2 do 77,1 mgNog·dm-3 w oczyszczalni Turbojet EP-2 i od 15,3 do 130,7 mgNog ·dm-3 w oczyszczalni Turbojet EP-4. Świadczy to o niestabilnie zachodzących procesach nitryfikacji i denitryfikacji. Duży wpływ na skuteczność procesów unieszkodliwiających azot miała temperatura ścieków w reaktorach biologicznych. Wpływ ten potwierdzono zależnością korelacyjną, która w oczyszczalni Turbojet EP-2 była wysoka (rxy=0,67) a w oczyszczalni Turbojet EP-4 bardzo wysoka (rxy=0,72). Skuteczność usuwania azotu ogólnego w oczyszczalni Turbojet EP-2 wyniosła średnio w okresie badań 61,3%, natomiast w oczyszczalni Turbojet EP-4 36,2%. W obu analizowanych obiektach w reaktorach biologicznych zaobserwowano duże wahania temperatury ścieków. Najniższe temperatury ścieków oscylujące w granicach 6÷8oC występowały w okresie 3 miesięcy w okresie rocznym, co przekładało się na niską skuteczność oczyszczania w tym okresie.
The aim of the study was to determine the effectiveness of the removal of nitrogen compounds in two domestic sewage treatment plants operate based on activated sludge technology. In addition, the effect of sewage temperature in the bioreactors analyzed the effectiveness of the elimination rate. Also analyzed the treatment Turbojet EP-2 with a capacity designed from 1.2 to 1.8 m3·d-1, and treatment Turbojet EP-4 with a capacity of 3.5÷5.0 designed m3·d-1. During the study period the two objects were hydraulically underloaded. Based on studies conducted in 2008-2010 found that the average concentration of total nitrogen in raw sewage were 82.6 mgNog·dm-3 in the treatment plant Turbojet EP-2 and 102.0 mgNog·dm-3 in the treatment Turbojet EP-4, the mean concentration of total nitrogen in treated wastewater were 30.2 mgNog·dm-3 in the treatment Turbojet EP-2 and 65.5 mgNog·dm-3 in the treatment Turbojet EP-4. During the study found large fluctuations in the concentrations of total nitrogen in treated wastewater, which ranged from 12.2 to 77.1 mgNog·dm-3 in the treatment Turbojet EP-2 and from 15.3 to 130.7 mgNog·dm-3 in the treatment Turbojet EP-4. This demonstrates the instability occurring processes of nitrification and denitrification. High impact on the percentage of disposal process was nitrogen temperature treatment in bioreactors. This effect was confirmed correlations, which in sewage Turbojet EP-2 was high (rxy=0.67) and treatment Turbojet EP-4 very high (rxy=0.72). The removal efficiency of total nitrogen in wastewater Turbojet EP-2 was on average 61.3% during the study period, while in treatment Turbojet EP-4 36.2%. In both study sites in the bioreactors seen large fluctuations in water temperature. The lowest sewage temperature is oscillating in the range of 6÷8°C occurred during the three months in the year, which translates into a low efficiency of treatment during this period.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2013, 3/IV
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative analysis of the quality of sewage discharged from selected agglomeration sewerage systems
Analiza porównawcza jakości ścieków odpływających z wybranych aglomeracji kanalizacyjnych
Autorzy:
Chmielowski, K.
Bugajski, P.
Kaczor, G. B.
Powiązania:
https://bibliotekanauki.pl/articles/947134.pdf
Data publikacji:
2016
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
agglomeration
domestic sewage
sewage composition
sewerage system
aglomeracja
skład ścieków
system kanalizacyjny
ścieki bytowe
Opis:
The study provides a comparative analysis of the quality of sewage discharged from selected sewerage systems. The analyzed data were collected from 10 agglomeration sewerage systems discharging sewage into collective wastewater treatment plants (WTP). The investigated pollution indicators included BOD5, CODCr, total suspended solids and biogenic indicators such as total nitrogen and total phosphorus. These results were compared with the outcomes reported in commonly available research papers on sewage disposal. Considering the concentration of individual pollution indicators, more detailed categories of sewage pollution were adopted in this work. The sewage was divided into five basic groups: I – highly concentrated, II – concentrated, III – moderately concentrated, IV – diluted, and V – highly diluted. The sewage categories accounted for the following pollution indicators: BOD5, CODCr, total suspended solids, total phosphorus and total nitrogen. Mean BOD5, CODCr and total suspended solids in raw sewage were higher than average values reported in the referenced literature. Contrary to that, concentration of total phosphorus in raw sewage was significantly lower than reported by other authors. The outcomes of this study suggest that the predictions concerning pollution degree of raw sewage made at WTP design stage should not be based exclusively on general values provided in literature reports.
W pracy przedstawiono analizę porównawczą jakości ścieków odpływających wybranymi systemami kanalizacyjnymi. Badania przeprowadzono w dziesięciu wybranych aglomeracjach kanalizacyjnych odprowadzających ścieki do oczyszczalni zbiorczych. Analizie poddano podstawowe wskaźniki zanieczyszczenia ścieków (BZT5, ChZTCr, zawiesina ogólna) oraz biogenne (azot ogólny i fosfor ogólny). Porównano średnie wartości poszczególnych wskaźników zanieczyszczenia ścieków odpływających z wybranych aglomeracji kanalizacyjnych. Uzyskane wyniki porównano z wartościami zestawionymi w ogólnodostępnej literaturze związanej z tematyką unieszkodliwiania ścieków. Do badań przyjęto podział ścieków ze względu na koncentrację poszczególnych wskaźników zanieczyszczenia. Ścieki podzielono na pięć zasadniczych grup (I – ścieki bardzo stężone, II – ścieki stężone, III – ścieki średnio stężone, IV – ścieki rozcieńczone, V – ścieki bardzo rozcieńczone). Uzyskane średnie wartości BZT5, ChZTCr i zawiesiny ogólnej w ściekach surowych były większe od wartości średnich przedstawianych w analizowanej literaturze. Natomiast stężenie fosforu ogólnego w ściekach surowych było zdecydowanie mniejsze niż podają inni autorzy. Wyniki przeprowadzonych badań wskazują, że podczas projektowania oczyszczalni ścieków należy zachować pewną ostrożność w prognozowaniu stężeń zanieczyszczeń w ściekach surowych wyłącznie na podstawie uogólnionych wartości podawanych w literaturze.
Źródło:
Journal of Water and Land Development; 2016, 30; 35-42
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stan techniczny sieci wodociągowych w małych wodociągach województwa małopolskiego i podkarpackiego
Technical conditions of water supply networks in small waterworks of the Malopolska and Podkarpackie voivodeships
Autorzy:
Bergel, T.
Kaczor, G.
Bugajski, P.
Powiązania:
https://bibliotekanauki.pl/articles/62152.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
woj.malopolskie
woj.podkarpackie
wodociagi
gminy wiejskie
gminy miejsko-wiejskie
siec wodociagowa
stan techniczny
Opis:
W pracy dokonano oceny stanu technicznego 70 sieci wodociągowych zlokalizowanych na terenach gmin wiejskich i miejsko-wiejskich w województwie małopolskim i podkarpackim. Z uwagi na duże zróżnicowanie wodociągów pod względem wielkości, podzielono je na pięć grup w zależności od liczby mieszkańców obsługiwanych przez wodociąg. Na podstawie danych na koniec 2009 r., pochodzących z dokumentacji eksploatacyjnych poszczególnych wodociągów, dokonano charakterystyki wieku i struktury materiałowej sieci wodociągowych, a następnie oceny ich stanu technicznego. W analizie poszczególnych wskaźników sieci wodociągowych, uwzględniono ich podział strukturalny tzn. analizowano przewody tranzytowe i magistralne, przewody rozdzielcze oraz przyłącza wodociągowe. Dodatkowym elementem analizy było zbadanie struktury uszkodzeń przewodów. Na podstawie przeprowadzonej analizy stwierdzono, iż w strukturze wiekowej sieci wodociągowych dominowały przewody w wieku do 25 lat, co po uwzględnieniu materiału z którego zostały wykonane pozwala stwierdzić, że w większości przypadków znajdowały się one na półmetku okresu trwałości technicznej. Analizowane sieci wodociągowe w zdecydowanej większości wybudowano z tworzyw termoplastycznych oraz w znacznie mniejszym procencie ze stali. W strukturze materiałowej przewodów, z kilkuprocentowym udziałem występowało również żeliwo i azbestocement. Intensywność uszkodzeń przewodów wodociągowych w woj. podkarpackim, w większości przypadków była nieco niższa niż w woj. małopolskim, co świadczy o lepszym ich stanie technicznym. Średnia intensywność uszkodzeń poszczególnych rodzajów przewodów wodociągowych w woj. podkarpackim, w przeciwieństwie do woj. małopolskiego, kształtowała się na podobnym poziomie jak obliczona dla małych wodociągów średnia krajowa. Awaryjność analizowanych przewodów (z wyjątkiem tranzytowych i magistralnych w woj. małopolskim), spełniała wymagania standardów europejskich Występuje ścisła zależność pomiędzy rodzajem uszkodzeń przewodów a ich strukturą materiałową. Przewody tranzytowe, magistralne i rozdzielcze zbudowane głównie z tworzyw termoplastycznych najbardziej podatne były na pęknięcia i złamania, natomiast przyłącza wodociągowe (w dużym procencie stalowe) na uszkodzenia korozyjne.
The paper evaluates the technical condition of 70 water supply networks situated in rural and urban-rural communes in Lesser Poland and Subcarpathian voivodeships. Because of large variation of the considered waterworks in terms of their size, they were divided into five groups according to the number of residents served by the waterworks. The age and material structure of the water supply system was characterized, followed by the evaluation of their technical condition based on data from the end of 2009, derived from the operational records of individual waterworks. The analysis of each water supply indicator included their structural division, i.e. the transit, main and distribution pipes as well as water supply connections were analyzed. Another aspect of the analysis was to examine the structure of damage to the pipes. The conducted analysis revealed that the pipes at the age of 25 years dominated in the age structure of the water supply networks, which, given the material they were made of, shows that in most cases they were halfway through their technical timeline. The vast majority of the analyzed water supply networks was constructed of thermoplastic materials and to a much lesser extent – of steel. Cast iron and asbestos cement constituted a few percent share of the material structure of pipes. The damage intensity to water pipes in the Subcarpathian voivodeship was in most cases somewhat lower than in the Lesser Poland voivodeship, reflecting their better technical condition. Unlike in the Lesser Poland voivodeship, the average failure rate of various types of water pipes in the Subcarpathian voivodeship, was at similar level as the national average calculated for small waterworks. Failure rate of the analyzed pipes (with the exception of transit and main pipes in the Lesser Poland voivodeship), meets the requirements of the European standards. There is a close correlation between the type of damage to the pipes and their material structure. Transit, main and distribution pipes, predominantly built of thermoplastic materials were the most susceptible to cracks and fractures, while water supply connections (largely made of steel) were the most susceptible to corrosion damage.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2013, 3/IV
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie metody trójkąta do obliczenia objętości wód infiltracyjnych i przypadkowych w kanalizacji sanitarnej
Application of the triangle method for the calculation of the infiltration and inflow volume in a sanitary sewer system
Autorzy:
Kaczor, G.
Bugajski, P.
Bergel, T.
Powiązania:
https://bibliotekanauki.pl/articles/61348.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
kanalizacja sanitarna
woda infiltracyjna
scieki
wody przypadkowe
metoda trojkatowa
Opis:
Celem badań było wykorzystanie metody trójkąta do obliczenia objętości wód infiltracyjnych i przypadkowych dopływających do kanalizacji sanitarnej, funkcjonującej w powiecie krakowskim (województwo małopolskie). Analizowana kanalizacja, o długości 10 km, wykonana jest z rur kamionkowych o średnicach 200, 250 i 300 mm. Wody infiltracyjne i przypadkowe, nazywane także wodami obcymi wpływają niekorzystnie na funkcjonowanie kanalizacji oraz oczyszczalni ścieków, co w konsekwencji może przekładać się na zanieczyszczenie wód odbiornika. Ich ilość w dopływach do kanalizacji powinna być szacowana za pomocą dostępnych metod obliczeniowych, a przyczyny występowania na bieżąco eliminowane. Przeprowadzone badania wykazały alarmujące objętości wód obcych dopływających do analizowanej kanalizacji, w roku 2010 stanowiły one 41,1%, w roku 2011 – 28,7%, a w roku 2012 – 23,4% łącznej rocznej objętości wód zanieczyszczonych. Objętość wód infiltracyjnych i przypadkowych dopływająca do badanej kanalizacji uzależniona była przede wszystkim od częstości występowania opadów, natomiast w mniejszym stopniu od ich sumy rocznej. Główną przyczyną dopływu wód przypadkowych do analizowanego systemu kanalizacyjnego, ustaloną na podstawie wizji terenowych oraz przeprowadzonych przez przedsiębiorstwo wodociągowe testów dymnych, są nielegalne podłączenia do przykanalików ściekowych wylotów rynien dachowych lub wpustów podwórzowych.
The aim of this study was the application of the triangle method for the calculation of the infiltration and inflow volume entering the sanitary sewer system operating in the Cracow County (Lesser Poland Voivodeship). The analyzed, 10 km long, sewer system is made of vitrified clay pipes with diameters of 200, 250 and 300 mm. Infiltration and inflow, also called extraneous water, adversely affect the operation of sewer systems and sewage treatment plants, what in turn may result in water contamination in the receiver. Amount of extraneous water in the inflows to sewer systems should be estimated using the available computational methods and their causes should be eliminated on an ongoing basis. The conducted study showed an alarming amount of extraneous water flowing into the analyzed sewer system, i.e. in 2010 it accounted for 41.1% (40033 m3), in 2011 – 28.7% (22224 m3), while in 2012 – 23.4% (16848 m3) of the total annual volume of polluted water. The volume of infiltration and inflow entering the examined sewer system depended primarily on the frequency of precipitation, and – to a lesser extent – on its annual total amount. Illegal connections of yard inlets or gutters to the sewage drains are the main cause of extraneous water inflow to the analyzed sewer system, as determined based on field inspections and smoke tests, conducted by the water supply company.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2013, 3/IV
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ wybranych miąższości filtrów piaskowych o przepływie pionowym na jakość oczyszczonych ścieków bytowych
Impact of Selected Thicknesses of Vertical Sand Filters on the Quality of Treated Domestic Wastewater
Autorzy:
Dacewicz, E.
Kaczor, G.
Bugajski, P.
Powiązania:
https://bibliotekanauki.pl/articles/1813764.pdf
Data publikacji:
2018
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
filtr piaskowy o przepływie pionowym
miąższość
ścieki bytowe
vertical sand filter
thickness
domestic wastewater
Opis:
W artykule przedstawiono wpływ miąższości warstwy filtracyjnej w filtrze piaskowym o przepływie pionowym na jakość oczyszczonych ścieków bytowych. Miąższość warstw w poszczególnych kolumnach wyniosła 15 cm, 30 cm, 45 cm, 60 cm oraz 90 cm. Badania efektywności usuwania związków organicznych oraz zawiesiny ogólnej wykonywano w warunkach zwiększającego się obciążenia hydraulicznego w zakresie od 20 dm3.m-2.d-1 do 80 dm3.m-2.d-1. Stwierdzono, że oczyszczanie ścieków bytowych w filtrze piaskowym o wysokości warstwy filtracyjnej 15 cm pozwoliło na uzyskanie bardzo niskich wartości BZT5 (średnio 8,7 mg O2.dm-3). Skuteczność zmniejszenia BZT5 w tym filtrze ukształtowała się na poziomie 96,4%. W przypadku ChZTCr zauważono wraz ze zmniejszaniem się wysokości złoża filtracyjnego wyraźny wzrost jego średniej wartości od 54,7 mg O2.dm-3do 175,9 mg O2.dm-3. Dla miąższości warstwy filtracyjnej równej 90 cm średnie usunięcie ChZTCr wyniosło 85,5%, natomiast zastosowanie złoża o miąższości 15 cm pozwoliło na średnie zmniejszenie ChZTCr o ponad 53%. Zawiesina ogólna była usuwana w zakresie od 25,7 mg. dm-3 do 29,6 mg. dm-3 niezależnie od wysokości złoża filtracyjnego. Średnia skuteczność zmniejszenia tego wskaźnika wyniosła 72,9%.
The paper presents the influence of the thickness of the filtration layer in the vertical flow sand filter on the quality of treated domestic wastewater. The thickness of the layers in individual columns was 15 cm, 30 cm, 45 cm, 60 cm and 90 cm. Studies on the removal efficiency of organic compounds and total suspended solids were carried out in the conditions of increasing hydraulic load within the range from 20 dm-3.m-2.d-1 to 80 dm-3.m-2.d-1. It was found that the treatment of domestic sewage in the sand filter with the height of filtration layer of 15 cm, allowed to obtain very low BOD5 (on average 8.7 mg O2.dm-3). The efficiency of reducing BOD5 in this filter was at the level of 96.4%. In the case of CODCr, a significant increase in its mean value – from 54.7 mg O2.dm-3to 175.9 mg O2.dm-3– was observed with the decreased height of the filter bed. For the thickness of the filtration layer equal to 90 cm, the average removal of CODCr was 85.5%, whereas the use of 15 cm thick filtration bed allowed for an average reduction of CODCr by over 53%. The total suspended solids were removed in the range from 25.7 mg. dm-3 to 29.6 mg. dm-3 regardless of the height of the filter bed. The mean reduction effectiveness of this indicator was 72.9%.
Źródło:
Rocznik Ochrona Środowiska; 2018, Tom 20, cz. 2; 1546-1563
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie metody ruchomego minimum do obliczenia objętości wód infiltracyjnych i przypadkowych w kanalizacji sanitarnej
The calculation of infiltration and inflow volume within sanitary sewer systems by using the moving minimum method
Autorzy:
Kaczor, G.
Bugajski, P.
Powiązania:
https://bibliotekanauki.pl/articles/60908.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
scieki
kanalizacja sanitarna
wody infiltracyjne
wody przypadkowe
doplyw wody
metody obliczen
metoda ruchomego minimum
Opis:
Celem badań było ustalenie wielkości dopływu wód infiltracyjnych oraz przypadkowych do wybranej kanalizacji sanitarnej przy wykorzystaniu metody ruchomego minimum. Poddany badaniom system kanalizacyjny zlokalizowany jest w powiecie krakowskim w województwie małopolskim. Dopływ wód obcych do ka-nalizacji badano w wieloleciu 2008-2011. Na podstawie analizy wyników badań, uzyskanych metodą ruchomego minimum ustalono, że udział wód infiltracyjnych w rocznych dopływach wód zanieczyszczonych do kanalizacji wynosił od 19,0 do 20,7%, natomiast udział wód przypadkowych od 19,5 do 31,4%. Największe do-pływy wód przypadkowych w analizowanym wieloleciu wystąpiły w roku 2010 (30 210 m3). Był to rok, który ze względu na roczną sumę opadów oceniany był jako bardzo wilgotny. Najniższe dopływy do kanalizacji wód przypadkowych (15 053 m3) wystąpiły w roku 2011 (rok bardzo suchy). Najwyższe dopływy wód infiltracyjnych (20 675 m3) wystąpiły natomiast w roku 2009 (rok suchy), a najniższe (14 805 m3) w roku 2011. Na podstawie przeprowadzonych badań wykazano, że w przypadku analizowanego systemu kanalizacyjnego występuje silna zależność pomiędzy roczną sumą opadów atmosferycznych i roczną objętością wód obcych dopływających do kolektorów ściekowych. Przeprowadzone badania wykazały, że metoda ruchomego minimum może być z powodzeniem stosowana do ustalania objętości wód infiltracyjnych i przypadkowych dopływających do kanalizacji sanitarnej.
The aim of the study was to determine the volume of infiltration and inflow within a selected sanitary sewer system by using the moving minimum method. The examined sewer system is located in Kraków County, Lesser Poland Voivodeship. Parasite water inflow into the sewer system was studied in the multiannual period of 2008–2011. Based on the analysis of the research results, obtained using the moving minimum method, it was determined that the infiltration fraction in the annual inflow of contaminated water into the sewer system was from 19.0 to 20.7%, while the fraction of extraneous water - from 19.5 to 31.4%. The largest inflows of extraneous water in the analyzed multiannual period occurred in 2010 (30 210 m3). Due to high total annual precipitation this year was evaluated as very wet. The lowest inflows of extraneous water to the sewer system (15 053 m3) were observed in 2011 (extreme dry year). On the other hand, the largest inflow of infiltration water (20 675 m3) occurred in 2009 (dry year) and the lowest (14 805 m3) - in 2011. The performed research demonstrated a strong correlation between the annual amount of precipitation and the annual volume of parasite water flowing into sewer interceptors in the analyzed sewer system. The study showed that the moving minimum method can be successfully applied to determine the volume of infiltration and inflow within sanitary sewer systems.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2012, 2/I
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ sumy rocznej opadów atmosferycznych na objętość wód przypadkowych dopływających do kanalizacji sanitarnej
The Effect of Total Annual Precipitation on the Volume of Accidental Water Entering Sanitary Sewage System
Autorzy:
Kaczor, G.
Chmielowski, K.
Bugajski, P.
Powiązania:
https://bibliotekanauki.pl/articles/1813833.pdf
Data publikacji:
2017
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
kanalizacja
ścieki
wody przypadkowe
opady
oczyszczalnia ścieków
sewerage system
sewage
accidental waters
precipitation
sewage treatment plant
Opis:
Celem badań była ocena siły korelacji pomiędzy roczną sumą opadów atmosferycznych i roczną objętością wód przypadkowych dopływających do 3 wybranych sieci kanalizacyjnych. Wody przypadkowe to najczęściej wody opadowe lub roztopowe przedostające się do wnętrza kanałów sanitarnych przez włazy studni kanalizacyjnych oraz nielegalnie wykonywane włączenia do przykanalików wylotów rynien dachowych, wpustów podwórzowych lub wylotów drenaży służących do odwodnienia posesji. Analizę oparto na 12 letnich ciągach pomiarowych, obejmujących sumy roczne opadów atmosferycznych dla Krakowa oraz roczne objętości wód przypadkowych dopływających do 3 rozdzielczych sieci kanalizacyjnych, odprowadzających ścieki bytowe z osiedli mieszkaniowych w latach 2004-2015. Przeprowadzone badania wykazały istotną statystycznie, bardzo wysoka korelację pomiędzy roczną sumą opadów atmosferycznych i roczną objętością wód przypadkowych dopływających do badanych sieci kanalizacyjnych. Na podstawie równań funkcji regresji obliczono, że wzrost sumy rocznej opadów o 100 mm spowoduje wzrost rocznej objętości wód przypadkowych dopływających do analizowanych kanalizacji od 2 305 aż do 14 866 m3. Uzyskane wyniki badań, powinny być sygnałem do podjęcia przez eksploatatorów sieci kanalizacyjnych intensywnych i skutecznych działań mających na celu wyeliminowanie nielegalnych podłączeń rynien dachowych lub wpustów podwórzowych do kolektorów sanitarnych.
The aim of the study was to find out the strength of the correlation between total annual precipitation and annual volume of accidental water entering three selected sewerage systems. Accidental water is usually precipitation or melt water entering the sanitary sewers via manhole wells or the outlets of rain gutters, yard gullies or local drainage systems illegally connected to the drains. The analysis included 12-year measurement series covering total annual precipitation for Kraków and annual volume of accidental water entering three distribution sewerage networks discharging domestic sewage from residential areas in the years 2004-2005. The study revealed a significant and very strong correlation between total annual precipitation and annual volume of accidental water entering the investigated sewerage systems. Results if regression equations showed that a 100 mm increase in total annual precipitation would enhance will the annual volume of accidental water supplied to the analyzed sewerage systems from 2 305 up to 14 866 m3. This clearly indicates the need to intensify the efforts aimed at elimination of illegal connections of rain gutters and yard gullies to the investigated sewerage systems.
Źródło:
Rocznik Ochrona Środowiska; 2017, Tom 19; 668-681
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies