Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "stainless steel" wg kryterium: Temat


Tytuł:
Electropolymerized polymer coatings for stainless steel
Autorzy:
Trzaskowska, P.
Piechna, M.
Ciach, T.
Powiązania:
https://bibliotekanauki.pl/articles/283988.pdf
Data publikacji:
2016
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
polymers
stainless steel
electropolymerization
Źródło:
Engineering of Biomaterials; 2016, 19, 138; 98
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the differentiation of structural and physicochemical properties of orthodontic wires of AISI 304 stainless steel
Autorzy:
Grygier, D.
Hoppe, V.
Zięty, A.
Rutkowska-Gorczyca, M.
Powiązania:
https://bibliotekanauki.pl/articles/284164.pdf
Data publikacji:
2018
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
stainless steel
orthodontics wire
microstructure
Opis:
Wires used for orthodontic arches play a very important role in the process of orthodontic treatment. In combination with the lock attached to the tooth, they move and align the teeth along the set trajectories. Wires of stainless steel are commonly used in orthodontics for several reasons: they are characterised by high resistance to corrosion, high strength and elasticity, formability and a possibility of obtaining defined properties through cold working and annealing during production process. The purpose of the research presented in the work is the analysis of differences of the selected structural properties in the context of corrosion resistance of the orthodontic wire material. The object of the research was edge arches of the 0.016”x0.022” size made of the stainless steel type AISI 304, provided by two different producers: G&H Orthodontics and Adenta. The research methodology involved analysis of chemical and phase composition of the tested alloy, microscopic tests with application of the light and electron microscopy methods, as well as electrochemical direct current measurements. The research presented in the work has shown significant differences in structural and physical-chemical properties of the orthodontic wires made of AISI 304 type stainless steel. Despite the fact, that the tested arches were manufactured of the theoretically the same materials, but by different producers, they significantly differ in chemical composition, metallurgical purity, phase composition and corrosion resistance. In addition, it is worth noticing that the tested materials, in terms of structure, do not meet the normative requirements obligatory for biomaterials.
Źródło:
Engineering of Biomaterials; 2018, 21, 146; 8-13
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Annealing behaviour of plastically deformed stainless steel 1.4307 studied by positron annihilation methods
Autorzy:
Dryzek, E.
Sarnek, M.
Siemek, K.
Powiązania:
https://bibliotekanauki.pl/articles/148014.pdf
Data publikacji:
2013
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
plastic deformation
positron annihilation
stainless steel
Opis:
Isochronal and isothermal annealing of stainless steel 1.4307 samples deformed by compression were investigated using Doppler broadening measurements of the annihilation line. We made an attempt to describe the obtained dependencies in terms of vacancy migration and sinking to the grain boundaries. The model assumed spherical grains with a homogeneous initial distribution of vacancies. The model was capable of following the isochronal annealing data quite accurately. However, the obtained activation energy of vacancy migration equal to 0.44 plus or minus 0.05 eV seemed too low. The isothermal annealing dependency was reproduced less precisely. The reason for this may be the presence of the alfa'-martensite particles in the samples, which can introduce additional defects seen by positrons in the temperature range in which the martensite reversion takes place.
Źródło:
Nukleonika; 2013, 58, 1; 215-219
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bactericidal properties of Cu doped TiO2 films deposited on medical stainless steel
Autorzy:
Sobczyk-Guzenda, A.
Owczarek, S.
Jakubowski, W.
Jędrzejczak, A.
Gazicki-Lipman, M.
Szymanowski, H.
Powiązania:
https://bibliotekanauki.pl/articles/284706.pdf
Data publikacji:
2017
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
stainless steel
RF PECVD technique
biomaterials
Źródło:
Engineering of Biomaterials; 2017, 20, no. 143 spec. iss.; 75
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Corrosion Resistance, EIS and Wettability of the Implants Made of 316 LVM Steel Used in Chest Deformation Treatment
Autorzy:
Kajzer, A.
Kajzer, W.
Gołombek, K.
Knol, M.
Dzielicki, J.
Walke, W.
Powiązania:
https://bibliotekanauki.pl/articles/355260.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
stainless steel
corrosion resistance
wettability
plate
Opis:
The paper presents the influence of mechanical surface damage on the physicochemical properties of plates after implantation made of CrNiMo stainless steel, used in the treatment of anterior surface deformity of the chest. Analysis of the data allowed us to investigate the effect of implant design and condition of their surface on the results of chest deformation treatment. Results of electrochemical, impedance and surface wettability tests and SEM observations were compared with clinical observations. When removing the plates we found only slight inflammatory-periosteal reactions. On the basis of obtained results, it can be stated that plates, in spite of mechanical damage of the surface, were characterized by good corrosion resistance, a fact which is confirmed by the results of clinical evaluation.
Źródło:
Archives of Metallurgy and Materials; 2016, 61, 2A; 767-770
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Studies of stainless steel exposed to sandblasting
Autorzy:
Horodek, P.
Eseev, M. K.
Kobets, A. G.
Powiązania:
https://bibliotekanauki.pl/articles/147075.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
stainless steel
sandblasting
defects
positron beam
Opis:
The influence of sandblasting on surface and subsurface of stainless steel is investigated using variable energy positron beam (VEP), positron annihilation spectroscopy (PAS), scanning electron microscopy (SEM), and atomic force microscopy (AFM). Samples of stainless steel were blasted using 110 μm particles of Al2O3 under different pressure and time duration. In the case of sandblasting for 90 s, the reduction of positron diffusion length depending on the applied pressure was observed. Sandblasting during 30 s leads only to the reduction of positron diffusion length to about 60 nm for all samples. Positron lifetimes close to 170 ps measured using positrons emitted directly from the source point to the presence of vacancies on the dislocation lines. SEM and AFM images show that surface roughness depends rather on pressure of sandblasting than time of exposition.
Źródło:
Nukleonika; 2015, 60, No. 4, part 1; 721-724
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of Initial Wear Period of Differently Coated Carbide Cutting Tools
Autorzy:
Bartoszuk, M.
Grzesik, W.
Powiązania:
https://bibliotekanauki.pl/articles/99561.pdf
Data publikacji:
2015
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
orthogonal cutting
coatings
tool wear
stainless steel
Opis:
In this paper the results of experimental studies concerning the phenomenon of initial period of the wear of differently coated sintered carbide tools when dry orthogonal cutting of an AISI 321 austenitic stainless steel are presented. The motivation for this study results from the lack of technological guides concerning the optimal choice of coated cutting tools for machining of corrosion resistant austenitic stainless steels. A number of cutting tool inserts with the plane rake face made of a fine H10F sintered carbide substrate with specially deposited TiN, including TiCN, TiAlN, AlTiN and AlCrN single layers were used in wear tests. Both rake and flank faces of the cutting inserts were examined by optical and confocal microscopy after controlled tool wear. The possible wear mechanisms in terms of changes of the tool-chip contact were investigated.
Źródło:
Journal of Machine Engineering; 2015, 15, 4; 37-45
1895-7595
2391-8071
Pojawia się w:
Journal of Machine Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of treatment conditions on cutting forces and surface roughness
Autorzy:
Labuda, W.
Powiązania:
https://bibliotekanauki.pl/articles/241665.pdf
Data publikacji:
2016
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
turning dynamometer
surface roughness parameter
stainless steel
Opis:
One of the greatest problems of modern production techniques is the achievement of an appropriate quality at minimal costs and accompanied by the production efficiency increase. Therefore, while designing the production process, the technology used should have a considerable influence on the durability and reliability of machine parts to be produced. During finish treatment, the final dimensions as well as functional properties are imparted to a given element by application of proper treatment type. The engineer has a range of production techniques to choose for the proper surface layer formation. It is crucial to find a suitable solution which will meet the requirements as well as the work conditions of a given machine part. The article presents the results of influence of treatment conditions during turning of shafts on the cutting forces and surface roughness parameter. A roller made of S235JR steel was used for the research. The cutting process was carried out on a universal CDS 6250 BX-1000 and CU500MRD centre lathes. Measurement of cutting forces during lathing process used DKM 2010 and Kistler turning dynamometers. The turning process was conducted by a cutting tool with CCMT09T304 PF removable plate. During the turning, the following machining parameters were used: cutting speed Vc = 150 m/min, feed f=0.106 mm/rev and cutting depth ap = 0.5, 0.75, 1.0, 1.25, 1.5, 1.75 mm. The surface roughness was measured by T8000 profilometer.
Źródło:
Journal of KONES; 2016, 23, 1; 207-213
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Finishing treatment of marine pump shafts made of X5CRNI18-10 steel
Autorzy:
Labuda, W.
Powiązania:
https://bibliotekanauki.pl/articles/244602.pdf
Data publikacji:
2018
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
turning dynamometer
temperature
cutting forces
stainless steel
Opis:
One of the greatest problems of modern production techniques is the achievement of an appropriate quality at minimal costs and accompanied by the production efficiency increase. Therefore, while designing the production process, the technology used should have a considerable influence on the durability and reliability of machine parts to be produced. During finish treatment, the final dimensions as well as functional properties are imparted to a given element by application of proper treatment type. The engineer has a range of production techniques to choose for the proper surface layer formation. It is crucial to find a suitable solution which will meet the requirements as well as the work conditions of a given machine part. The article presents the results of influence of cutting parameters change on temperature and cutting forces during turning process of stainless steel. A shaft made of 304L stainless steel was used for the research. The cutting process was carried out on a universal CDS 6250 BX-1000 centre lathe. Measurement of cutting forces during lathing process used DKM 2010 turning dynamometer. The turning process was conducted by a cutting tool with CCET09T302R-MF insert by DIJET. During the turning, the following machining parameters were used: cutting speed Vc = 152, 219, 304 m/min, feed f = 0.044, 0.062, 0.083 mm/rev and cutting depth ap = 0.4, 0.8, 1.2, 1.6 mm. The view of the nose radius of cutting tool before and after the turning process was made by the Smartzoom 5 microscope.
Źródło:
Journal of KONES; 2018, 25, 2; 215-222
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Corrosion Resistance of Some Stainless Steels in Chloride Solutions
Autorzy:
Kasprzyk, D.
Stypuła, B.
Powiązania:
https://bibliotekanauki.pl/articles/352719.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
stainless steel
chemical composition
corrosion
Ringer solution
Opis:
The present work compares corrosion behaviour of four types of S30403, S31603, S32615 austenitic and S32404 austeniticferritic stainless steels in chloride solutions (1%, 3% NaCl) and in Ringer solution, at 37°C temperature. Corrosion resistance was determined by potentiodynamic polarization measurements and a thirty day immersion test conducted in Ringer solution. The immersion test was performed in term of biomedical application. These alloy were spontaneously passivated in all electrolytes, wherein S30403, S31603 and S32404 undergo pitting corrosion. Only S32615 containing 5.5% Si shows resistance to pitting corrosion.
Źródło:
Archives of Metallurgy and Materials; 2017, 62, 2A; 711-714
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improvement of the stainless steel electropolishing process by organic additives
Autorzy:
Lochynski, P.
Kowalski, M.
Szczygiel, B.
Kuczewski, K.
Powiązania:
https://bibliotekanauki.pl/articles/779206.pdf
Data publikacji:
2016
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
electropolishing
organic additives
surface roughness
stainless steel
Opis:
The influence of organic additives on the process of surface electropolishing of AISI 304 type steel was determined. Additives were selected in initial potentiodynamic tests pursuant to the plateau analysis on the current/potential curves. The assessment of the operational effectiveness of additives consisted in determining the relationship between surface gloss after electropolishing and the mass loss of the sample and in determining surface roughness. The applied electropolishing bath consisted of a mixture of concentrated acids: H3PO4  and H2SO4 and the following organic additives were used: triethylamine, ethanolamine, diethanolamine, triethanolamine, diethylene glycol monobutyl ether and glycerol. The best electropolishing result, i.e. low roughness and high gloss of stainless steel surface with a relatively low mass loss of the sample at the same time were obtained for baths containing triethanolamine.
Źródło:
Polish Journal of Chemical Technology; 2016, 18, 4; 76-81
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Corrosion Reactivity in the Pre-Clinical Study of 316L and 321 Stainless Steel for Dentistry Applications
Autorzy:
Neaga, V.
Benea, Lidia
Powiązania:
https://bibliotekanauki.pl/articles/2048753.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
corrosion
electrochemical methods
stainless steel
human saliva
Opis:
Now, the use of any medical device based on metals or alloys, especially intended for dentistry applications, is impossible without preclinical evaluation of its anticorrosion properties. Today, the use of stainless steels with AISI standardization, with predilection 316L and 321, are preferred for ergonomic reasons due to their high operational reliability and optimal mechanical properties for functionality over time. In this regard, 316L and 321 stainless steels are tested for comparison in the solution that simulates human saliva with different pH. Stainless steel samples were subjected to corrosion in Fusayama-Meyer and Carter-Brugirard saliva. In-situ electrochemical measurements were applied, such as the open circuit potential (OCP) and electrochemical impedance spectroscopy (EIS). The results show that the corrosion resistance of 316L is superior to 321 in saliva solution at both pH values.
Źródło:
Archives of Metallurgy and Materials; 2022, 67, 1; 371-376
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of changing of cutting parameters on temperature and cutting forces during turning process of stainless steel with CCET09T302R-MF insert
Autorzy:
Labuda, W.
Powiązania:
https://bibliotekanauki.pl/articles/243223.pdf
Data publikacji:
2017
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
turning dynamometer
temperature
cutting forces
stainless steel
Opis:
One of the greatest problems of modern production techniques is the achievement of an appropriate quality at minimal costs and accompanied by the production efficiency increase. Therefore, while designing the production process, the technology used should have a considerable influence on the durability and reliability of machine parts to be produced. During finish treatment, the final dimensions as well as functional properties are imparted to a given element by application of proper treatment type. The engineer has a range of production techniques to choose for the proper surface layer formation. It is crucial to find a suitable solution which will meet the requirements as well as the work conditions of a given machine part. The article presents the results of influence of change of cutting parameters on temperature and cutting forces during turning process of stainless steel. A shaft made of 304L stainless steel was used for the research. The cutting process was carried out on a universal CDS 6250 BX-1000 centre lathes. Measurement of cutting forces during lathing process used DKM 2010 turning dynamometer. The turning process was conducted by a cutting tool with CCET09T302R-MF insert by DIJET. During the turning, the following machining parameters were used: cutting speed Vc = 226 m/min, feed f = 0.044, 0.062, 0.083, 0.106 mm/rev and cutting depth ap = 0.25, 0.5, 0.75, 1.0 mm. The chemical composition of steel was measured by Solaris-ccd plus optical spectrometer.
Źródło:
Journal of KONES; 2017, 24, 4; 133-140
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Study on the Electrical Characteristics and Oxidation Resistance of the STS434L-High Chrome Powder Green Compact at the High-Temperature
Autorzy:
Park, J. W.
Jung, W. Y.
Park, D. K.
Ahn, I. S.
Powiązania:
https://bibliotekanauki.pl/articles/354543.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
stainless steel
fecraloy
oxidation resistance
metallic oxide
Opis:
Metallic oxide layer of heat resistant element contributes to the high-temperature oxidation resistance by delaying the oxidation, and also has positive effect on the electrical resistivity increase. In this study, the green compacts of Fe-Cr-Al powder mixed with STS434L were oxidized at 950°C up to 210 hrs in order to consider the effect of metal oxide on the oxidation and electrical resistance. It exhibited the low oxidation resistance in case of 434L only, however it increased as the amount of Fe-Cr-Al powder in the 434L compact. The higher electrical resistivity was observed at the Fe-Cr-Al compact with and 434L powder. The metal oxides of (Fe0.6C0.4)2O3, Cr2O3, and Fe2O3 contributed to the electrical resistivity, whereas Al2O2 took a role of oxidation resistance.
Źródło:
Archives of Metallurgy and Materials; 2018, 63, 1; 431-435
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of intermetallic phases on corrosion behavior and mechanical properties of duplex stainless steel and super-duplex stainless steel
Autorzy:
Paulraj, P
Garg, R.
Powiązania:
https://bibliotekanauki.pl/articles/102625.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
stainless steel
intermetallic phases
corrosion
mechanical properties
welding
Opis:
Duplex Stainless Steels (DSS) and Super Duplex Stainless Steel (SDSS) have excellent integration of mechanical and corrosion properties. However, the formation of intermetallic phases is a major problem in their usage. The mechanical and corrosion properties are deteriorated due to the presence of intermetallic phases. These phases are induced during welding, prolonged exposure to high temperatures, and improper heat treatments. The main emphasis of this review article is on intermetallic phases and their effects on corrosion and mechanical properties. First the effect of various alloying elements on DSS and SDSS has been discussed followed by formation of various intermetallic phases. The intermetallic phases affect impact toughness and corrosion resistance significantly. Their deleterious effect on weldments has also been reviewed.
Źródło:
Advances in Science and Technology. Research Journal; 2015, 9, 27; 87-105
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies