Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "nusselt number" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Optimization of geometric and flow parameters of solar air heater roughened with artificial roughness by Taguchi method
Autorzy:
Sahu, Mukesh Kumar
Mishra, Shivam
Kumar, Avinash
Powiązania:
https://bibliotekanauki.pl/articles/27312207.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
roughness
nusselt number
friction factor
Taguchi method
optimization
Opis:
The paper presents the investigation of the optimum design parameters of a solar air heater (SAH) having wire ribs as artificial roughness by using the Taguchi method. The solar air heater has arc shape roughness geometry with apex upstream flow on the absorber plate. The objective of this paper is to obtain a set of parameters that deliver maximum thermo-hydraulic performance. For this objective, a new parameter the thermo-hydraulic improvement parameter (ηTHIP), has been introduced. For the present analysis, the effects of Reynolds number (Re), relative roughness pitch (P/e), angle of attack (α), and relative roughness height (e/Dh), denoted by A, B, C, and D, respectively, have been considered. An (L18 = 61 · 3 2 ) orthogonal array (OA) was chosen as an experimental plan for applying the Taguchi method. The set of control factors for the solar air heater SAH which delivers the maximum Nusselt number (Nu), and minimum friction factor (fr) – are A6B2C2, and A1B1C3 respectively. To obtain the maximum THIP the experimental set-up requires only one single run using the parameter A6B2C2, hence there is no need to run it all 54 times.
Źródło:
Archives of Thermodynamics; 2023, 44, 3; 3--33
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Heat transfer and friction factor correlation for inclined spherical ball roughened solar air heater
Autorzy:
Murmu, Ramesh
Kumar, Parmanand
Singh, Hari N.
Powiązania:
https://bibliotekanauki.pl/articles/240765.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
renewable energy
spherical ball
relative roughness pitch
relative roughness height
nusselt number
friction factor
angle of attack
Opis:
Flow mechanism under roughened solar air heater is quite complex. This paper is an effort towards determining the governing equations for heat transfer and friction factor for inclined spherical balls roughened ducts. With the availability of these equations, it is easier to predict the thermal and thermohydraulic performance of such roughened solar air heaters. The governing equations are derived based on the experimental data generated under actual outdoor condition at the test rig designed and fabricated at the terrace of the Mechanical Engineering Department, the National Institute of Technology Jamshedpur in India, in terms of roughness and flow parameters. Maximum augmentation in Nusselt number and friction factor for varying relative roughness pitch, relative roughness height, spherical ball height to diameter ratio, and angle of attack was respectively found to be of the order of 2.1 to 3.54 times, 1.87 to 3.21 times, 2.89 to 3.27 times and 1.74 to 3.56 times for Nusselt number and 0.84 to 1.79 times, 1.46 to 1.91 times, 1.67 to 2.34 times and 1.21 to 2.67 times for friction factor in comparison to non-roughened duct. The optimum roughness parameters under present investigation have been found.
Źródło:
Archives of Thermodynamics; 2020, 41, 2; 3-34
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Augmentation in heat transfer and friction of three sides over one side dimple roughened solar duct
Autorzy:
Kumar, Vikash
Powiązania:
https://bibliotekanauki.pl/articles/240256.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
dimple roughened
relative roughness pitch
relative roughness height
dimple depth to diameter ratio
nusselt number
friction factor
Opis:
Providing roughness is an effective method to heat fluids to high temperature. Present paper make use of concave dimple roughness on one and three sides of roughened ducts aimed at determining rise in heat transfer and friction of three sides over one side roughened duct. Three sides roughened duct produces high heat transfer compared to one side roughened. Results are shown as a rise in Nusselt number and friction factor of three sides over one side roughened duct. Experimental investigation was conducted under actual outdoor condition at National Institute of Technology Jamshedpur, India to test various sets of roughened collectors. Roughness parameter varied as relative roughness pitch 8–15, relative roughness height 0.018–0.045, dimple depth to diameter ratio 1–2, Reynolds number 2500– 13500 at fixed aspect ratio (width/hight) 8. Highest enhancement in Nusselt number for varying relative roughness pitch, height, and diameter ratio was respectively found as 2.6 to 3.55 times, 1.91 to 3.42 times and 3.09 to 3.94 times compared to one side dimple roughened duct. Highest rise in friction for three sides over one side roughened duct for these varying parameters was respectively found as 1.62 to 2.79 times, 1.52 to 2.34 times and 2.21 to 2.56 times. To visualize the effect of roughness parameter on heat transfer and friction factor, variation in Nusselt number and friction factor for varying roughness parameters with Reynolds number is shown.
Źródło:
Archives of Thermodynamics; 2020, 41, 3; 57-89
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies