Flow mechanism under roughened solar air heater is quite
complex. This paper is an effort towards determining the governing equations for heat transfer and friction factor for inclined spherical balls roughened ducts. With the availability of these equations, it is easier to predict
the thermal and thermohydraulic performance of such roughened solar air
heaters. The governing equations are derived based on the experimental
data generated under actual outdoor condition at the test rig designed and
fabricated at the terrace of the Mechanical Engineering Department, the
National Institute of Technology Jamshedpur in India, in terms of roughness and flow parameters. Maximum augmentation in Nusselt number and
friction factor for varying relative roughness pitch, relative roughness height,
spherical ball height to diameter ratio, and angle of attack was respectively
found to be of the order of 2.1 to 3.54 times, 1.87 to 3.21 times, 2.89 to 3.27
times and 1.74 to 3.56 times for Nusselt number and 0.84 to 1.79 times, 1.46
to 1.91 times, 1.67 to 2.34 times and 1.21 to 2.67 times for friction factor
in comparison to non-roughened duct. The optimum roughness parameters
under present investigation have been found.
Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies