Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "chrząstka" wg kryterium: Temat


Wyświetlanie 1-8 z 8
Tytuł:
Physiological and histological conditionings of articular cartilage regeneration techniques and clinical application of these techniques
Fizjologiczne i histologiczne uwarunkowania technik regeneracji chrząstek stawowych oraz ich zastosowania kliniczne
Autorzy:
Włodarski, Krzysztof H.
Szczęsny, Grzegorz
Brodzikowska, Aniela
Powiązania:
https://bibliotekanauki.pl/articles/2152242.pdf
Data publikacji:
2021-08-06
Wydawca:
Fundacja Edukacji Medycznej, Promocji Zdrowia, Sztuki i Kultury Ars Medica
Tematy:
osteoarthritis
articular cartilage
chonrogenesis
choroba zwyrodnieniowa stawów
chrząstka stawowa
chondrogeneza
Opis:
In clinical setting no spectacular treatment results confirmed using histological approaches were noted as compared with these obtained in laboratory research (finding the regeneration built of the hyaline cartilage in the damaged area in the treated patients is very rare since, as a rule the regeneration is built of the fibrous cartilage). Numerous and increasingly frequent procedures aimed at regeneration of the articular cartilage using platelet rich plasma (PRP), isolated autogenous chondrocytes or mesenchymal precursor cells in patients with osteoarthritis provide access to the vast research material for the analysis of the efficacy and safety of the treatment, based on which, no definitely adverse consequences of the applied methods were noted, such as life-threatening consequences due to new tissue formation. However, the knowledge of the underlying mechanisms indicates the necessity of exercising caution in qualifying patients for such procedures and many years long monitoring in order to the fastest possible diagnosing and successful treatment of the complications.
W warunkach klinicznych nie odnotowano spektakularnych, potwierdzanych metodami histologicznymi wyników leczenia jakie są uzyskiwane w badaniach laboratoryjnych (stwierdzenie u leczonych chorych wytworzenia w miejscu ubytku regeneratu zbudowanego z chrząstki szklistej jest rzadkością; regułą jest w zasadzie wytworzenie regeneratu chrząstki włóknistej). Olbrzymia i szybko rosnąca liczba wykonywanych zabiegów mających na celu regenerację chrząstek stawowych, w tym z użyciem osocza bogatopłytkowego, izolowanych autogennych chondrocytów czy mezenchymalnych komórek prekursorowych u chorych leczonych z powodu choroby zwyrodnieniowej stawów, udostępnia olbrzymi materiał badawczy dla analizy skuteczności i bezpieczeństwa terapii, na podstawie którego, jak dotąd, nie stwierdzono jednoznacznie negatywnych skutków stosowanych terapii w postaci groźnych dla życia powikłań wynikających choćby z nowotworzenia. Jednak znajomość mechanizmów ich działania zmusza do zachowania daleko idącej ostrożności w kwalifikowaniu chorych oraz ich stałego i wieloletniego monitorowania w celu jak najszybszego wykrycia i skutecznego wyleczenia powstałych powikłań.
Źródło:
Polish Journal of Sports Medicine; 2021, 37(3); 127-145
1232-406X
2084-431X
Pojawia się w:
Polish Journal of Sports Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania własności ruchowych zdegenerowanych stawów synowialnych
Tribological properties of degenerate synovial joints
Autorzy:
Koziarski, C.
Trzaskacz, T.
Ferenc, Z.
Powiązania:
https://bibliotekanauki.pl/articles/971540.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
biotribologia
tarcie toczno-ślizgowe
chrząstka stawowa
biotribology
rolling-sliding friction
articular cartilage
Opis:
W ludzkim organizmie chrząstka stawowa jest jednym z tych elementów, które są najbardziej narażone na zmiany przeciążeniowo-zwyrodnieniowe. W pracy przedstawiono wyniki badań, które mają na celu określenie własności tribologicznych zdegenerowanych chrząstek stawowych człowieka, a co się z tym wiąże stopnia zużycia biologicznego węzła ciernego. Badania przeprowadzono na drodze doświadczalnej, z wykorzystaniem modeli fizycznych. W badaniach próbka i przeciwpróbka wykonują ruch ślizgowo-toczny, co odpowiada możliwie wiernie ruchowi wzajemnemu powierzchni ciernych w stawie. Pomiary momentu tarcia realizowano dla ruchu wahadłowego, przy zachowaniu warunków płynnego tarcia toczno-ślizgowego. Badania realizowano przy sile nacisku Fn = 0÷105[N] i prędkości poślizgu vs = {0, 3, 6, 9}[mm/s] przy prędkości obrotowej w punkcie pomiarowym ω = 0,33[s-1] Materiał badawczy klasyfikowano pod względem uszkodzeń powierzchni chrząstki stawowej. Pozwoliło to na porównanie kolejnych stadiów degeneracji chrząstki i odniesienie ich do zmian parametrów tribologicznych w postaci momentu tarcia i współczynnika tarcia na badanych powierzchniach.
Joint cartilage in the human body is one of those elements that is most vulnerable to overload and degenerative changes. These changes are influenced by factors such as traffic accidents, lack of physical activates or metabolic disturbances. In this paper, the results of research aimed at the determination of the degeneration rate of the cartilage of a human joint on its tribological properties are presented. This experimental research was carried out using physical models. To carry out this research, a test stand modelling a fundamental scheme of loading and motion for the knee joint had been constructed. The measurements of the friction moment were realised for the fluctuate motion, with the proceeding of the time of rolling- sliding fluid friction. The research was realised for load force Fn = 0÷105[N]. (Sliding velocity vs = {0, 3, 6, 9}[mm/s], and the speed of rotation in measuring point ω = 0.33[s-1]) The specimen and counter specimen used in the testing are in sliding/rolling contact, which reflects, to a maximum degree possible, the relative motion of frictional surfaces in a joint. The results of this research were used for the evaluation of the influence of degenerative changes on tribological changes in the joint cartilage.
Źródło:
Tribologia; 2012, 5; 55-63
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microscopic tribological analysis of the knee joint
Mikroskopowa analiza tribologiczna w stawie kolanowym
Autorzy:
Ryniewicz, A. M.
Ryniewicz, A.
Pukaluk, A.
Pałka, P.
Powiązania:
https://bibliotekanauki.pl/articles/188937.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
knee joint
meniscus
articular cartilage
SEM
AFM
staw kolanowy
łąkotka
chrząstka stawowa
Opis:
The aim of the conducted research was the evaluation of the topography and the structure of the superficial layer of meniscus and articular cartilage. These are surfaces that optimise the friction and lubrication process in the knee joint. The animal samples of the menisci and the articular cartilage were examined. The research was performed using scanning electron microscopes and an atomic force microscope. The structure of the surface of meniscus and articular cartilage is very regular. The collagenous fibres, which are embedded in the ground substance, are parallel to the surface. The undulation of the surface was observed. In the area of the anterior horn on tibia side of both menisci as well as in the anterior area of tibial plateau, the concavity and convexity pattern is evident. The observed cavities enable the accumulation of the synovial fluid. The synovial fluid plays the role of the lubricant in the knee joint, and its presence is highly desired during the load transmission.
Celem przeprowadzonych badań była ocena topografii i struktury łąkotek oraz powierzchni stawowych, które zabezpieczają i optymalizują proces tarcia i smarowania w stawie kolanowym. Materiałem badań były łąkotki pobrane z prawidłowych stawów zwierzęcych oraz tkanka chrzęstna wypreparowana z powierzchni stawowych. Badania były realizowane na mikroskopach skaningowych oraz mikroskopie sił atomowych. Struktura warstwy wierzchniej chrząstki włóknistej oraz szklistej wykazała dużą regularność. Włókna kolagenowe biegnące równolegle do powierzchni i zatopione w substancji podstawnej tworzą łagodnie pofalowaną strukturę. Układ wgłębień i wzniesień jest najbardziej wyraźny na części przedniej plateau kości piszczelowej oraz w obszarze rogu przedniego łąkotek, po stronie kontaktującej się z plateau kości piszczelowej. W zaobserwowanych wgłębieniach może gromadzić się ciecz synowialna, która pełni rolę środka smarnego, i której obecność jest wysoce pożądana podczas przenoszenia obciążeń wewnątrz stawu kolanowego.
Źródło:
Tribologia; 2017, 273, 3; 147-154
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Methodology for Testing a Joint Cartilage
Metodyka badania chrząstek stawowych
Autorzy:
Mańkowska-Snopczyńska, Anita
Piekoszewski, Witold
Szczerek, Marian
Tuszyński, Waldemar
Kotela, Ireneusz
Kotela, Andrzej
Diem, Tadeusz
Powiązania:
https://bibliotekanauki.pl/articles/1857829.pdf
Data publikacji:
2020
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
research methodology
friction tests
articular cartilage
metodyka badań
badanie tarciowe
chrząstka stawowa
Opis:
A research method was developed to analyse the tribological properties of cartilage tissue. Based on the literature data and the possibility of obtaining samples of appropriate dimensions, the frequency and amplitude of friction tests were adopted. Based on the previously conducted preliminary tests, other test parameters were proposed, such as the frictional contact load and the number of test runs. It was assumed that the results of the research will be the friction coefficient and the wear intensity of the tribological system. According to the developed method, a series of verification tests was carried out in which the friction contact was lubricated in various ways with the selected lubricants. The results of tests of animal cartilage in non lubricated contact were used as the reference basis for all the tested associations. The friction tests showed good method resolution and satisfactory repeatability. In the case of wear characteristics, a greater scatter of test results was observed. It is probably related to the varied geometrical structure of the cartilage surface as well as the elastic properties of the bone on which the tissue was placed. The correctness of the obtained results and a relatively good resolution of the tribological test method were found.
Opracowano metodę badań w zakresie analizy właściwości tribologicznych tkanki chrzęstnej. W oparciu o dane literaturowe i możliwości pozyskania próbek o odpowiednich wymiarach przyjęto częstotliwość i amplitudę badań tarciowych. Na podstawie wcześniej prowadzonych badań wstępnych zaproponowano pozostałe parametry badań, takie jak obciążenie styku tarciowego i liczbę cykli biegu badawczego. Przyjęto, że rezultatem badań będą współczynnik tarcia i intensywność zużywania systemu tribologicznego. Zgodnie z opracowaną metodą przeprowadzono serię badań weryfikacyjnych, w których styk tarciowy smarowany był w zróżnicowany sposób wytypowanymi do badań środkami. Jako bazę odniesienia dla wszystkich badanych skojarzeń przyjęto wyniki badań zwierzęcej tkanki chrzęstnej w styku niesmarowanym. Badania tarciowe wykazały dobrą rozdzielczość metody oraz satysfakcjonującą powtarzalność, biorąc pod uwagę charakterystyki tarciowe. W przypadku charakterystyk zużyciowych zaobserwowano większy rozrzut wyników badań. Prawdopodobnie związane jest to ze zróżnicowaną strukturą geometryczną powierzchni tkanki chrzęstnej, jak również z własnościami sprężystymi kości. Stwierdzono poprawność uzyskanych wyników i stosunkowo dobrą rozdzielczość metody badań tribologicznych.
Źródło:
Tribologia; 2020, 294, 6; 29-38
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of acoustic signal processing methods in detecting differences between open and closed kinematic chain movement for the knee joint
Autorzy:
Karpiński, Robert
Machrowska, Anna
Maciejewski, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/118153.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Promocji Wiedzy
Tematy:
knee joint
kinetic chain
signals
articular cartilage
staw kolanowy
łańcuch kinetyczny
sygnały
chrząstka stawowa
Opis:
The paper presents results of preliminary research of analysis of signals recorded for open and closed kinematic chain in one volunteer with chondromalacia in both knees. The preliminary research was conducted in order to establish the accuracy of the proposed method and will be used for formulating further research areas. The aim of the paper is to show how FFT, recurrence plots and recurrence quantification analysis (RQA) can help in bioacoustic signals analysis.
Źródło:
Applied Computer Science; 2019, 15, 1; 36-48
1895-3735
Pojawia się w:
Applied Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of the biomechanical behaviour of articular cartilage in hindfoot joints
Autorzy:
Venturanto, C.
Pavan, P. G.
Forestiero, A.
Carniel, E. L.
Natali, A. N.
Powiązania:
https://bibliotekanauki.pl/articles/307388.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
ankle joint
articular cartilage
constitutive model
numerical analysis
staw skokowy
chrząstka stawowa
analiza numeryczna
Opis:
Numerical models represent a powerful tool for investigating the biomechanical behavior of articular cartilages, in particular in the case of complex conformation of anatomical site. In the literature, there are complex non-linear-multiphase models for investigating the mechanical response of articular cartilages, but seldom implemented for the analysis of high organized structure such as the foot. In the present work, the biomechanical behavior of foot cartilage is investigated by means of a fiber-reinforced hyperelastic constitutive model. The constitutive parameters are obtained through the comparison between in vitro experimental indentation tests on cartilage and numerical analysis data interpreting the specific experimental conditions. A finite element model of the hindfoot region is developed. Particular attention is paid to model cartilage in order to respect its morphometric configuration, including also the synovial capsule. The reliability of the procedure adopted is evaluated by comparing the numerical response of tibio-talar joint model with in vivo experimental tests mimicking the foot response in stance configuration.
Źródło:
Acta of Bioengineering and Biomechanics; 2014, 16, 2; 57-65
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Określanie współczynnika tarcia pary ciernej: chrząstka stawowa – biomateriał
Determination of the friction coefficient of friction pair: cartilage and biomaterial
Autorzy:
Andrzejewska, A.
Mazurkiewicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/99031.pdf
Data publikacji:
2016
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
tarcie
chrząstka stawowa
smarowanie
implant chrząstki stawowej
tribometr
friction
articular cartilage
lubrication
articular cartilage implant
tribometer
Opis:
W pracy przedstawiono wyniki badań współczynnika tarcia pary ciernej chrząstka stawowa – biomateriał. Przeprowadzone badania pozwoliły wyznaczyć współczynnik tarcia tkanki chrzęstnej oraz wzorca (przeciwpróbki), wykonanego z biomateriału szklanego i biopolimeru. W badaniach zaobserwowano wpływ tarcia suchego oraz hydrodynamicznego na zmiany współczynnika tarcia różnych biomateriałów.
This paper presents results of the friction coefficient of friction pair: cartilage and biomaterial. In this investigation was determine friction coefficient of cartilage and counterspecimen made of glass and biopolimer. Also was observed influence of dry and hydrodynamic friction to changes friction coefficient for different biomaterials.
Źródło:
Aktualne Problemy Biomechaniki; 2016, 11; 15-20
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza właściwości tłumiących chrząstki w stawie skokowym
Damping properties of articular cartilage in ankle
Autorzy:
Klekiel, T.
Będziński, R.
Powiązania:
https://bibliotekanauki.pl/articles/261369.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
staw skokowy
chrząstka
naprężenia w chrząstce
kontakt w stawie skokowym
element skończony
nieliniowy model materiału
materiał hipersprężysty
ankle
articular cartilage
stress in cartilage
contact in ankle joint
finite element
nonlinear material model
Opis:
Niniejszy artykuł przedstawia analizę mechanizmu rozpraszania energii przez chrząstkę stawu skokowego człowieka. Wykonano analizę mającą na celu określenie prawdopodobieństwa powstawania urazu powierzchni stawowej pod wpływem obciążenia silnym impulsem. Opracowano model numeryczny stawu uwzględniający kość piszczelową, kość skokową, powierzchnie stawowe oraz więzadła. Sztywność układu uzyskano uwzględniając więzadła w postaci elementów sprężystych. Na podstawie opracowanego modelu, dokonano analizy wpływu zmian właściwości chrząstki i więzadeł na stopień tłumienia energii obciążenia. Wyniki badań numerycznych uwzględniają zarówno zmiany sztywności poszczególnych struktur, jak również zmiany modeli konstytutywnych materiałów użytych w modelu. Wyznaczono zależność pomiędzy strukturą geometryczną chrząstki a jej zdolnością do rozpraszania energii. Na drodze eksperymentów numerycznych wyznaczono warunki, przy których wystąpi uraz powierzchni stawowej.
This article presents an analysis of the energy dissipation in the ankle during impact load. The aim of study was to analyze different material models of cartilage for selected conditions in which the contact of surface is destroyed. The numerical model includes tibia and talus with articular cartilage surfaces and ligaments. Based on the model, the changes in the material properties of cartilage were investigated for research the damping behavior of cartilage under impact load. The damping properties were analyzed based on the reaction force in the support. The differences in the force values were used for comparison of the selected material models. The numerical experiments show mechanism of destruction in the cartilage layer during plastic deformations. This destruction moment was detected by the yield stress of cartilage.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2016, 22, 4; 198-206
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies