Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "ion" wg kryterium: Temat


Tytuł:
New Approach to Non-Volatile Metal Ion Production Using Plasma Ion Source with Internal Evaporator
Autorzy:
Turek, Marcin
Droździel, Andrzej
Pyszniak, Krzysztof
Filiks, Janusz
Węgierek, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/2206283.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
ion sources
ion implantation
ion beams
Opis:
A new approach to application the internal evaporator in an arc discharge ion source is presented, namely a crucible with a plug made of feeding substance. This solution is suitable especially for high-melting point metallic feeding substances. The ion source was tested using Ni and Cr. Basic ion source characteristics, i.e. dependences of ion current and discharge voltage on discharge and filament currents as well as on the external magnetic field flux density are shown and discussed in order to find optimal working conditions. The maximal ion currents were 18 μA for Ni+ and 38μA for Cr+. The stability of the ion current was also tested. It was proven that ion source is able to provide intense ion beam current long enough to perform irradiations with the fluence of ~5×1015 cm-2 confirming the usefulness of the design for ion implantation purposes.
Źródło:
Advances in Science and Technology. Research Journal; 2022, 16, 5; 20--27
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Suppressing of Co-Extracted Electrons in a Negative Ion Source-Numerical Simulation
Autorzy:
Turek, Marcin
Węgierek, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/2201879.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
particle-in-cell simulations
negative ion source
ion beam extraction
Opis:
Electron co-extraction and suppression by a transverse magnetic fields is studied within a two dimensional particle-in-cell numerical model of surface ionisation ion source with beveled extraction opening. A novel approach of data presentation is proposed, based on the fact that dependences of co-extracted current on the filter strength could be approximated by four parameters only, describing e.g. initial electron current value and cut-off B value. In the paper the influence of extraction system geometry is considered – it is shown that the cut-off B value increases with the size of the opening in the extraction electrode, while the inclination of the extraction opening walls does not play any significant role. It is demostrated that the most of electron is eliminated by hiting the extraction electrode walls, however up to 30 % of electrons were lost by encountering the extraction channel walls due to the modification of their trajectories by the filter field. The influence of the magnetic filter field placement is also investigated – the center of the filter field has to be no further than 2 mm form the extraction channel orifice in order to achieve minimal values of the cut-off field (~20 mT). The possibly low extraction voltages are preferable, as the ammount of co-extracted electrons grows rapidly with Vext resulting in e.g. threefold increase of cut-off parameter value when extraction voltage is changed from 1 kV up to 10 kV. Within the considered model the filter field does not have any significant influecne on extracted H- current.
Źródło:
Advances in Science and Technology. Research Journal; 2022, 16, 5; 1--10
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Usuwanie jonów ołowiu(II) z modelowych roztworów wodnych metodą wymiany jonowej
Removal of Pb2+ ions from model aqueous solutions using the exchange method
Autorzy:
Bożęcka, A.
Bożęcki, P.
Kasprzyk, P.
Sanak-Rydlewska, S.
Powiązania:
https://bibliotekanauki.pl/articles/2072508.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
jonity
wymiana jonowa
jony ołowiu
ion-exchange resins
ion exchange
lead ions
Opis:
W pracy podano wyniki badań usuwania jonów Pb2+ z modelowych roztworów wodnych z wykorzystaniem procesu wymiany jonowej na jonicie C 160 firmy Purolite. Porównano trzy sposoby wykonywania procesu wymiany jonowej: metodę przepływową w biurecie, metodę dynamiczną z wykorzystaniem mieszadła mechanicznego oraz metodę dynamiczną z zastosowaniem wytrząsarki. Zakres badanych stężeń wyjściowych jonów ołowiu wynosił od 6 do 110 mg/dm3.
Results of Pb2+ ions removal from model aqueous solutions are presented in the paper. Ion exchange resins C 160 made by Purolite were used in research. Three different methods of ion exchange process, i.e. flow method in the burette, dynamic method using a mechanical stirrer and dynamic method using a shaker are compared. Scope of initial concentrations of lead ions was 6-M10 mg/L.
Źródło:
Inżynieria i Aparatura Chemiczna; 2013, 3; 152--154
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
0 niepewnościach stężenia wzorców stosowanych podczas kalibracji potencjometrycznych elektrod jonoselektywnych
About the uncertainty of concentration standards applied in the calibration of potentiometric ion-selective electrodes
Autorzy:
Wiora, J.
Powiązania:
https://bibliotekanauki.pl/articles/152458.pdf
Data publikacji:
2008
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
elektroda jonoselektywna
niepewność
stężenie
aktywność jonów
ion-selective electrode
uncertainty
concentration
ion activity
Opis:
W artykule przedstawiono relacje pomiedzy potencjałem elektrody jonoselektywnej a stężeniem jonów w roztworze. Przedstawiono przykład wykonania wzorca aktywności. Przeanalizowano niepewność stężenia jonów we wzorcach przygotowywanych poprzez rozpuszczanie soli, we wzorcach powstałych poprzez rozcieńczenia oraz we wzorcach otrzymanych automatycznie metodą wielokrotnego rozcieńczania wzorca.
The relationship between the potential E of the ion-selective electrode and ion concentration c are presented in the paper - eqs. (1)-5). The operations needed to prepare an activity standard, basing on eqs. (7) - (10), are listed and an example is given, haw to make it. Basing on eq. (11), linking concentration c, mass of salt m* and volume of solution V, the relative concentration uncertainty ur(c) is derived - eq. (12), and using a scale and non-ideal salt not having 100% content (cont) of substance of interest, the eq. (14) is obtained. After dilutions - eq. (15), concentration uncertainty changes - eq. (17). The next example is placed illustrating the change. The concentration uncertainties of standards obtained using multiple dilution method implemented on the automatic system SAWCEJS [5] are calculated in sec. 4.
Źródło:
Pomiary Automatyka Kontrola; 2008, R. 54, nr 5, 5; 318-321
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal Desorption of Argon Implanted into Gallium Arsenide
Autorzy:
Turek, Marcin
Droździel, Andrzej
Pyszniak, Krzysztof
Węgierek, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/2201837.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
thermal desorption spectroscopy
gallium arsenide
ion implantation
Opis:
Thermal desorption of Ar implanted with energies 150 keV and 100 keV with fluence 1×10^16 cm^-2 into GaAs is considered. A sudden release of Ar is observed in temperature range 1100 -1180 K as a single narrow peak in TDS (Thermal Desorption Spectroscopy) spectra. This is accompanied by a strong background signal from atmospheric Ar trapped in various parts of the spectrometer. Desorption peak shift analysis allows estimation of desorption activation energy values - these are 3.6 eV and 2.5 eV for implantation energies 150 keV and 100 keV, respectively. These results are comparable to that measured for Ar implanted into germanium target.
Źródło:
Advances in Science and Technology. Research Journal; 2022, 16, 4; 318--326
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Testing the cobalt ion emission on the stand for different angles of positioning the components of the metal–metal hip joint endoprosthesis
Stanowiskowe badania emisji jonów kobaltu dla różnych kątów osadzenia komponentów endoprotezy stawu biodrowego typu metal –metal
Autorzy:
Wiśniewski, Tomasz
Libera, Michał
Powiązania:
https://bibliotekanauki.pl/articles/2055619.pdf
Data publikacji:
2021
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
endoprostheses
wear
ion emission
endoprotezy
zużycie
emisja jonów
Opis:
The paper deals with the subject related to the assessment of the influence of the axis angle of the metal components of the hip joint on the emission of cobalt ions. The tribological tests were carried out with the use of a simulator for the examination of hip joint endoprostheses, the structure of which enables the fixation of endoprosthesis components in accordance with the anatomical structure of the human hip joint. During the tests, the simulator performs flexion and extension movements as well as loads occurring in the human hip joint while walking. Loss-wear tests were carried out for nine variants of the “head–cup” system settings. These settings were determined on the basis of CT images obtained from patients after arthroplasty. After the tribological tests were completed, samples of the lubricating fluid with the wear products suspended in it were collected in order to determine the concentration of cobalt ions, which was carried out using the atomic absorption spectrometry method. As a result, the influence of the head antetorsion angle (α) and the acetabular anteversion angle (β) on the concentration of cobalt ions was analysed.
W pracy poruszono problematykę związaną z oceną wpływu kątów elementów endoprotezy stawu biodrowego na emisję jonów kobaltu. Badania tribologiczne przeprowadzono przy użyciu symulatora do badania endoprotez stawu biodrowego, którego konstrukcja umożliwia mocowanie elementów endoprotezy zgodnie z budową anatomiczną stawu biodrowego człowieka. Podczas testów symulator wykonuje ruchy zgięcia i wyprostu oraz obciążenia występujące w stawie biodrowym człowieka podczas chodzenia. Testy zużycia przeprowadzono dla dziewięciu wariantów ustawień układu „głowa–panewka”. Ustawienia te zostały określone na podstawie obrazów CT uzyskanych od pacjentów po endoprotezoplastyce. Po zakończeniu badań tribologicznych pobrano próbki cieczy smarującej z pozostałymi w niej produktami zużycia w celu oznaczenia stężenia jonów kobaltu, co przeprowadzono metodą atomowej spektrometrii absorpcyjnej. W rezultacie przeanalizowano wpływ kąta antetorsji głowy (α) i kąta antewersji panewki (β) na stężenie jonów kobaltu.
Źródło:
Tribologia; 2021, 297, 3; 57--64
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modification of Optical, Electronic and Microstructural Properties of PET by 150 keV Cs+ Irradiation
Autorzy:
Musiatowicz, Michał
Turek, Marcin
Droździel, Andrzej
Pyszniak, Krzysztof
Grudziński, Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/2206284.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
polymer modification
PET
ion implantation
FTIR spectroscopy
Raman spectroscopy
conducting layer
Opis:
Thick (0.125 mm) sheet samples of PET were irradiated with 150 keV Cs+ ion beam with fluences in the range from 10^13 cm^-2 up to 10^16 cm^-2). Raman and UV-VIS spectroscopy measurements shown destruction of numerous bonds within the polymer – this effect intensifies with fluence. Raman spectroscopy shows the presence of amorphous graphitelike structures as the broad G band appears in the collected spectrum. The analysis of absorbance spectra also confirms formation of numerous carbon clusters leading to a formation of vast conducting structures in the modified layer of the polymer. One can observe the decrease of optical bandgap from 3.85 eV (typical for pristine PET) to 1.05 eV for the sample implanted with the highest fluence, the effect is weaker than for lighter alkali metal ions. The estimated average number of C atom in a clusters reaches in such case values close to 1100. The changes in the polymer structure lead to intense reduction of electrical sheet resistivity of the modified samples by ~ 8 orders of magnitude in the case of severely modified sample. The dependence of resistivity on temperature has also been measured. The plots of ln(σ) vs 1/T show that band conductivity or nearest neighbor hopping between conducting structures prevail in the considered case
Źródło:
Advances in Science and Technology. Research Journal; 2022, 16, 5; 11-19
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rozróżnianie aminokwasów z wykorzystaniem elektronicznego języka
Discrimination of amino acids by electronic tongue
Autorzy:
Jańczyk, M.
Wróblewski, W.
Ciosek, P.
Powiązania:
https://bibliotekanauki.pl/articles/155667.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
elektroniczny język
aminokwasy
elektrody jonoselektywne
PLS
electronic tongue
amino acids
ion-selective electrodes
Opis:
Obecnie potrzebne są metody szybkiego, dokładnego, a przede wszystkim taniego oznaczania aminokwasów w próbkach biologicznych. Do takich technik należy potencjometryczny elektroniczny język, który pozwala na rozróżnianie próbek ciekłych. W pracy przedstawiono zastosowanie potencjometrycznego elektronicznego języka do klasyfikowania 5 aminokwasów. Sprawdzono możliwość rozpoznania poszczególnych analitów w roztworach o różnych pH, a następnie wykorzystując metodę częściowych najmniejszych kwadratów (PLS) rozróżniono poszczególne aminokwasy.
In the last few years medical discoveries showed that presence of amino acids can be associated with many diseases. Usually, these compounds are determined using HPLC method (high performance liquid chromatography), however, due to its noxiousness, new methods are investigated. Application of electronic tongue system can be an alternative method for fast, accurate, affordable determination of amino acids in biological samples. This device is used for analysis and classification of complex liquid samples. Its main advantage is the ability to distinguish between samples containing various components on-line, without prior sample preparation and modification. In this paper there are presented preliminary studies on the recognition of 5 amino acids (glutamic acid, alanine, serine, arginine, aspartic acid) with use of a sensor array composed of ion-selective electrodes of various selectivity. Chemical images of the samples were obtained by measuring the electrode signals in solutions of amino acids for various pH ranging from 2.5 to 11.5. The possibility of identification of individual analytes in solutions of different pH was examined with use of the Partial Least Squares Analysis.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 6, 6; 535-537
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparing of Microhardness of the Stellite 6 Cobalt Alloy Implanted with 175 keV Mn+ Ions and 120 keV N+ Ions
Autorzy:
Kamiński, Mariusz
Budzyński, Piotr
Szala, Mirosław
Turek, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/103323.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
ion implantation
Stellite 6
microhardness
cobalt alloy
implantacja jonów
Stellit 6
mikrotwardość
stop kobaltu
Opis:
Nowadays, high-precision machines require lightweight materials with very high strength. Ion implantation is used to improve the mechanical strength of the material. A further paper presents the influence of manganese and nitrogen ion implantation on changes of microhardness of the surface layer of cobalt alloy. Samples were analyzed with the SEM-EDS Phenom ProX microscope. Microhardness was assessed with the Vickers method, and the loads of 1 gf (0.00981 N) and 5 gf (0.049 N) was applied using a FM-800 from Future-Tech microhardness meter. At a load of 1 gf, the penetration depth of the implanted specimens was reached not exceeding 0.5 um. At this depth, all samples showed an increase in microhardness compared to the unimplanted sample. The highest increase in microhardness was achieved after implantation of Mn ions with dose D=1∙1017 Mn+/cm2 and energy E=175 keV. The increased load on the indenter to 5 gf reduced the microhardness differences between implanted and unimplanted samples.
Źródło:
Advances in Science and Technology. Research Journal; 2019, 13, 3; 179-185
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania wstępne kinetyki flotacji jonowej i precypitacyjnej glinu
Preliminary kinetic investigations of aluminium ion and precipitate flotation
Autorzy:
Kawalec-Pietrenko, B.
Rybarczyk, P.
Powiązania:
https://bibliotekanauki.pl/articles/2071929.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
flotacja jonowa
flotacja precypitacyjna
glin
stała szybkości
ion flotation
precipitate flotation
aluminum
rate constant
Opis:
Zbadano wpływ pH surówki, stężenia kolektora oraz prędkości przepływu powietrza na przebieg flotacji jonowej i precypitacyjnej Al(III). Stwierdzono, że pH surówki ma istotny wpływ na szybkość flotacji. Stwierdzono, że dla tych samych stężeń kolektora i prędkości przepływu powietrza stałe szybkości flotacji przyjmują wyższe wartości w warunkach flotacji precypitacyjnej niż jonowej.
An influence of the initial solution pH, collector concentration and air flow velocity on a course of Al(III) ion and precipitate flotation was investigated. It was found that the flotation course distinctly depended on the initial solution pH. It was also found that flotation rate constant values were higher in case of precipitate flotation than those for ion flotation, provided that both flotations occured under the same process conditions of collector concentration and air flow velocity.
Źródło:
Inżynieria i Aparatura Chemiczna; 2012, 6; 336-337
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oczyszczanie 1,3-propanodiolu z brzeczki fermentacyjnej z zastosowaniem ekskluzji jonów
Separation of 1,3-propanediol from fermentation broth by ion exclusion
Autorzy:
Rukowicz, B
Miesiąc, I.
Alejski, K.
Powiązania:
https://bibliotekanauki.pl/articles/2072900.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
1,3-propanodiol
brzeczka fermentacyjna
ekskluzja jonów
1,3-propanediol
fermentation broth
ion exclusion
Opis:
W pracy przedstawiono możliwość zastosowania ekskluzji jonów w procesie oczyszczania 1,3-propanodiolu z brzeczki fermentacyjnej. Badania przeprowadzono na kationicie w formie sodowej. Wstępnie odsoloną frakcję produktu uzyskano z ok. 50% wydajnością separacji 1,3-propanodiolu. Stopień odsolenia brzeczki wyniósł 80÷90%, a końcowe oczyszczenie i odbarwienie 1,3-propanodiolu przeprowadzono stosując wymianę jonową. W wyniku procesu otrzymano oczyszczony roztwór 1,3-propanodiolu o stężeniu 16,5 g/L.
Application of ion exclusion for the separation of 1,3-propanediol from fermentation broth was examined. The study was carried out on a cation exchange resin in the sodium form. The product fraction with the desalination degree of 80-90% and 50% separation yield of 1,3-propanediol we obtained. The final purification of 1,3-propanediol was carried out using the ion exchange. As a result of this process the purified solution of 1,3-propanediol (16.5 g/L) was obtained.
Źródło:
Inżynieria i Aparatura Chemiczna; 2014, 4; 288--289
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody zadawania skokowej zmiany aktywności jonów na membranie elektrody jonoselektywnej
Methods of realizations the ion activity step at the membrane of an ion-selective electrode
Autorzy:
Wiora, A.
Powiązania:
https://bibliotekanauki.pl/articles/152460.pdf
Data publikacji:
2008
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
elektroda jonoselektywna
dynamika
czas odpowiedzi
celka pomiarowa
ion-selective electrode
dynamic
response time
measuring setup
Opis:
Celem artykulu jest przedstawienie metod realizacji skokowej zmiany aktywności jonów na membranie elektrody jonoselektywnej. Opisano metodę z wirującym naczyniem i zmodyfikowaną metodę wstrzykową, które opracowano na potrzeby Laboratorium Miernictwa Przemysłowego, metody z elektrodami w układzie równoległym i szeregowym do jednoczesnego pomiaru za pomocą kilku elektrod jonoselektywnych oraz metody z jedną elektrodą pomiarową w układzie, w tym najnowszą celkę pomiarową z dwoma dyszami, która po wstępnych badaniach wydaje się być najlepszym rozwiąniem spośród wczesniej prezentowanych.
The work presents realizations of the ion activity steps at the membrane of ion-selective electrodes (ISEs). The most important elements in properly conducted experiments are exclusions of opening the (ISE - probe solution - reference electrode) measuring circuit and exclusions of mixing two different solutions before the contact with ISE's membrane. The rotating beaker methods and modified injection methods elaborated for didactic purpose used in frame or the Industry Measurement are described. The parallel and serial methods designed for simultaneous measuring using several ISEs have important drawbacks impossible to eliminate. The methods using only one ISE, including a measuring set-up with two jets, appear to be the best solution among presented methods.
Źródło:
Pomiary Automatyka Kontrola; 2008, R. 54, nr 5, 5; 314-317
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tribological Tests of the Ceramic Cutting Tools after Yttrium (Y+) and Rhenium (Re+) Ion Implantation
Badania tribologiczne ceramicznych narzędzi skrawających po implantacji jonami ITRU (y+) i RENU (re+)
Autorzy:
Morozow, Dmitrij
Rucki, Mirosław
Siemiątkowski, Zbigniew
Gutsalenko, Yuriy
Powiązania:
https://bibliotekanauki.pl/articles/190309.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
ion implantation
tribological test
wear
friction
cutting tool
implantacja jonów
test tribologiczny
zużycie
tarcie
narzędzie skrawające
Opis:
The paper presents the results of investigations on the tribological properties of cutting tools after ion implantation. The research focused on the inserts made out of nitride ceramics IS9 (Si3N4 with additives) and combined ceramics IN22 (Al2O3 + TiCN) available on the market. The inserts rake surfaces were covered with yttrium and rhenium coatings by means of ion implantation with different dozes. Both unimplanted and coated surfaces underwent tribological tests of the block-on ring type. The experiments demonstrated that, in general, ion implantation with rhenium (Re+) and yttrium (Y+) provided a decrease in surface friction forces. In the case of IN22 ceramics, both rhenium and yttrium ions improved wear resistance of cutting inserts. On the other hand, Re+ implantation provided the best wear resistance of the IS9 ceramics.
Artykuł opisuje wyniki badań właściwości tribologicznych narzędzi skrawających po implantacji jonów. Badania dotyczyły narzędzi wykonanych z ceramiki azotkowej IS9 (Si3N4 + dodatki) i ceramiki mieszanej IN22 (Al2O3 + TiCN), dostępnych na rynku. Na powierzchnie natarcia naniesiono powłoki itru i renu metodą implantacji jonów o różnych dawkach. Pokryte i niepokryte powierzchnie zostały poddane testom tribologicznym w parach typu rolka–klocek. Badania wykazały, że generalnie implantacja jonów renu (Re+) i itru (Y+) zmniejsza siły tarcia na powierzchni. W przypadku ceramiki IN22 iony zarówno renu, jak i itru zwiększyły odporność płytek skrawających na zużycie. Z drugiej strony, najlepszą odporność na zużycie ceramiki IS9 zapewniły jony renu.
Źródło:
Tribologia; 2019, 285, 3; 71-77
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efektywność flotacji jonowej i precypitacyjnej mieszaniny jonów cynku i glinu
Effectiveness of ion and precipitate flotation of zinc and aluminum ions mixture
Autorzy:
Kawalec-Pietrenko, B.
Rybarczyk, P.
Powiązania:
https://bibliotekanauki.pl/articles/2071933.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
cynk
glin
flotacja jonowa
flotacja precypitacyjna
stopień wyflotowania
aluminum
zinc
ion flotation
precipitate flotation
removal ratio
Opis:
Zbadano wpływ pH surówki oraz stężenia kolektora na efektywność półpe riodycznych flotacji jonowej i precypitacyjnej, zachodzących w roztworach zawierających mieszaniny jonów Zn(II) i Al(III). Stwierdzono, iż w warunkach flotacji jonowej zachodzącej w roztworach kwaśnych występuje konkurencja pomiędzy flotowanymi kationami w tworzeniu związków z kolektorem. W obecności kolektora kationowego bromku cetylotrimetyloamonio- wego możliwa jest selektywna flotacja cynku z roztworów zawierających mieszaninę jonów Zn(II) i Al(III), dla wartości pH wyższych niż 11.
An influence of the initial solution pH and collector concentration on the effectiveness of semi-batch ion and precipitate flotations occurring in solutions containing mixtures of Zn(II) and Al(III) ions was investigated. It was found that a competition between Zn(II) and Al(III) ions in creation of compounds with the collector took place. The zinc selective flotation from the solution containing mixture of Zn(II) and Al(III) ions was possible for pH value higher than 11.
Źródło:
Inżynieria i Aparatura Chemiczna; 2012, 6; 338-339
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Możliwości sterowania kinetyką wydzielania z roztworu pojedynczych jonów w procesie jednoczesnej flotacji kilku jonów metali
Possibilities of ion separation kinetics control during simultaneous flotation of several metalions
Autorzy:
Kawalec-Pietrenko, B.
Rybarczyk, P.
Powiązania:
https://bibliotekanauki.pl/articles/2072227.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
flotacja jonowa
flotacja precypitacyjna
stała szybkości
jony metali
ion flotation
precipitate flotation
rate constant
metal ions
Opis:
Zbadano wpływ pH surówki flotacyjnej, stężenia kolektora i prędkości przepływu powietrza na przebieg flotacji jonowej i precypitacyjnej mieszaniny Al(III), Cu(II) i Zn(lI). Najwyższe wartości stałych szybkości flotacji badanych metali uzyskano dla procesów prowadzonych dla pH około 8, tj. w warunkach flotacji precypitacyjnej. Wykazano, że stałe szybkości flotacji badanych metali są proporcjonalne do prędkości przepływu powietrza flotującego w potędze około 0,8.
Influence of the initial solution pH, collector concentration and air velocity on the course of Al(III), Cu(II) and Zn(II) ion and precipitate flotation was investigated. The highest values of flotation rate constants for aluminum, copper and zinc were observed for the precipitate flotation when a value of the initial solution pH was about 8. It was concluded that flotation rate constants for investigated metals were proportional to air velocity in the power of about 0.8.
Źródło:
Inżynieria i Aparatura Chemiczna; 2013, 5; 433--434
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies