Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "POWER" wg kryterium: Temat


Tytuł:
Currents physical components theory and p-q power theory in the control of the three-phase shunt active power filter
Teoria składowych fizycznych prądu oraz teoria mocy p-q w zastosowaniu do sterowania równoległym energetycznym filtrem aktywnym
Autorzy:
Firlit, A.
Powiązania:
https://bibliotekanauki.pl/articles/154209.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
energetyczny filtr aktywny
teorie mocy
jakość energii elektrycznej
active power filter
power theories
electric power quality
Opis:
This paper presents the comparison of the control algorithms for a three phase, three wire shunt active power filter. The control algorithms are based on: the current's physical components theory and the p-q power theory. The active power filter operation under the distorted supply voltage at the point of common coupling condition is considered. The comparison concerns the aspects of: filtering current harmonics, reactive power compensation (defined in the fundamental harmonic domain), supply current balancing and dynamic performance. The results of the laboratory investigation, using the fast prototyping system dSPACE, are given in the paper.
W artykule przedstawiono porównanie algorytmów sterowania trójfazowym, trójprzewodowym równoległym energetycznym filtrem aktywnym. Algorytmy sterowania opracowano na podstawie dwóch teorii mocy: teorii składowych fizycznych prądu oraz teorii mocy p-q. Badaniom podlegała praca energetycznego filtru aktywnego w warunkach odkształconego napięcia zasilającego w punkcie wspólnego przyłączenia. Za kryterium porównania przyjęto: filtrację wyższych harmonicznych prądu odbiornika, kompensację mocy biernej (zdefiniowanej w dziedzinie podstawowej harmonicznej), symetryzację asymetrycznych prądów linii zasilającej odbiornik oraz dynamikę energetycznego filtru aktywnego. W artykule zamieszczono wyniki pomiarów i badań otrzymane na zbudowanym stanowisku laboratoryjnym trójfazowego, trójprzewodowego równoległego energetycznego filtru aktywnego z wykorzystaniem systemu szybkiego prototypowania dSPACE.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 3, 3; 110-115
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyznaczanie składowych mocy z wykorzystaniem funkcji korelacji
Determination of power components with the use of correlation functions
Autorzy:
Górniak, M.
Powiązania:
https://bibliotekanauki.pl/articles/156934.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
moc chwilowa
funkcja korelacji
teorie mocy
wyznaczanie składowych mocy
pomiar mocy
DSP
instantaneous power
correlation function
power theories
calculation of power components
power measurement
Opis:
W artykule przedstawiono sposób wyznaczania składowych mocy według podejścia zaproponowanego przez Hashada i Hartmana. Dla porównania wyników uzyskanych tym sposobem, zastosowano definicje mocy zalecane przez standard IEEE 1459-2000. Badania były wykonywane pod kątem wykorzystania cyfrowego przetwarzania sygnałów do określania parametrów mocy. Przeprowadzono je dla przebiegów sinusoidalnych i okresowych niesinusoidalnych. Zastosowano wyznaczanie mocy zgodne ze standardem IEEE: na podstawie wartości chwilowych, według Budeanu oraz Depenbrocka. Do wyznaczania mocy według podejścia Hashada i Hartmana napisany został program w języku C++ "Funkcje" oraz arkusz obliczeniowy w programie Excel. W pracy przedstawiono wyniki badań symulacyjnych.
A comparison of determination methods of power parameters by Hashad and Hartman way and by recommendation of IEEE 1459?2000 standard, in order to make the use digital signal proc-essing for describing the power components there are presented in the paper. Hashad and Hartman power functions properties are described in Chapter 2. In the paper a determination of power according to IEEE standard was applied: on the basis of instantane-ous values, by Budeanu way and by Depenbrock way. The formulas are described in Chapter 3. For calculation of power by Hashad and Hartman way program in C++ language called "Funkcje" and spread-sheet of Excel program were created. Thanks to the written software the comparison and evaluation of Hashad and Hartman way with actually valid IEEE 1459-2000 standard methods were carried out. The comparison and evaluation with use of sinusoidal and periodic non-sinusoidal waveforms were made up. The examples of voltage and current simulation waveforms are shown on Figures 2, 4 and on Figures 3, 5 appropriate to them functions of power waveforms. The most important results of re-search and intermediate conclusions are presented in Chapter 5, in Tables 1 to 6 and on Figures 6 to 8. The main conclusions and future direction of the work are pointed out in Chapter 6.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 5, 5; 464-470
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of Selected Parameters of Coal Burned in a Combined Heat and Power Plant
Autorzy:
Paśnikowska-Łukaszuk, Magdalena
Powiązania:
https://bibliotekanauki.pl/articles/2023979.pdf
Data publikacji:
2021
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
coal
heat and power plant
energy
combined heat and power
Opis:
The paper discusses the use of fossil fuels and the process of their extraction in Poland. Hard coal used on a daily basis in one of the Polish combined heat and power plants was described, followed by monthly measurements of coal parameters. Daily and total analyzes of the obtained measurement results of hard coal were carried out in accordance with the applicable standards. The differences in the values of coal from the same source but imported at different time intervals are shown, which result from the weather conditions and the method of hard coal storage. Negative correlations occurred between ash content and calorific value, heat of combustion and volatile matter, as detailed in the work conclusions.
Źródło:
Advances in Science and Technology. Research Journal; 2021, 15, 2; 108-115
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania mieszalnika z przegrodami niestandardowymi własnej konstrukcji
Studies of mixer equipped with non-standard baffles of own construction
Autorzy:
Szaferski, W.
Broniarz-Press, L.
Powiązania:
https://bibliotekanauki.pl/articles/2070897.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
moc mieszania
przegrody niestandardowe
zapotrzebowanie energii
power consumption
non-standard baffles
power requirements
Opis:
W pracy przedstawiono wyniki badań wpływu kształtu niestandardowych przegród własnej konstrukcji, rodzaju mieszanej cieczy oraz wysokości zawieszenia mieszadła na nakłady energetyczne w procesie mieszania w zbiorniku ze standardową turbiną Rushtona. Pomiary wykonano w wodnych roztworach wysokocząsteczkowego poliakryloamidu (Rokrysol WF1) oraz w wodzie destylowanej.
This paper reports the results of effect of the geometry of non-standard baffles of own construction, kind of liquid agitated and height of agitator mounting on the mixing energy consumption in a mixer equipped with the standard Rushton disc turbine. Aqueous solutions of high-molecular poly-acrylamide (Rokrysol WF1) and distilled water were used as liquid phase.
Źródło:
Inżynieria i Aparatura Chemiczna; 2010, 2; 117-118
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Low-Power Autonomous Sensor Module for Biomedical Applications
Autorzy:
Sondej, T.
Maciejewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/114430.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
low-power
sensor
biomedical application
Opis:
The paper presents the construction of an energy-efficient, stand-alone measurement module, designed for use in biomedical applications. The paper discusses the use of an algorithm implementing the acquisition and processing of data, whose main objective was to minimize energy consumption. For the construction of the measuring module, there are used a microcontroller with Cortex-M4F core and two external digital sensor systems: (1) analog-front-end circuit, designed to measure the ECG signal, and (2) a 3-axis system of an integrated accelerometer, gyroscope and magnetometer, made in MEMS technology. In order to minimize the energy consumption, the solutions proposed include dynamic frequency management, the introduction of sleep modes, and the use of selected hardware features of the microcontroller. The proposed techniques and algorithms are implemented to measure the ECG signal at a sampling rate of 250 Hz. Experimental studies of the sensor module constructed were carried out. As a result of the energy saving techniques used, the working time of the device was extended by more than 6 times.
Źródło:
Measurement Automation Monitoring; 2016, 62, 6; 206-208
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Model częstotliwościowy metody detekcji wyższych harmonicznych wykorzystującej przekształcenie Parka
A frequency model of the harmonics detection method based on Park transformation
Autorzy:
Buła, D.
Pasko, M.
Powiązania:
https://bibliotekanauki.pl/articles/152216.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
energetyczne filtry aktywne
jakość energii
wyższe harmoniczne
active power filters
power quality
higher harmonics
Opis:
W artykule przedstawiono model w dziedzinie częstotliwości metody detekcji wyższych harmonicznych wykorzystującej przekształcenie Parka.Omawiana metoda jest stosowana w algorytmach sterowania trójfazowych energetycznych filtrów aktywnych. Algorytmy te realizowane są natomiast w dziedzinie czasu. Przedstawiony model pozwala na opracowanie modelu częstotliwościowego całego układu oraz ocenę wpływu parametrów układu na jego charakterystyki filtracyjne.
The model in the frequency domain of the harmonics detection method using Park transformation is presented in the paper. This method is usually used in control algorithms of three-phase active power filters which are implemented in the time domain. The presented model allows obtaining the active power filter model in frequency domain and assess the impact of system parameters on the characteristics of the filter. The study shows the model derivation of the base detection method (Fig. 1), but it can be applied to other similar methods for detection of selected harmonic components or its positive and negative components. The transformation of the derived model into symmetrical components (Fig. 3) allows determining the independent transmittance for positive and negative components. This enables obtaining the frequency responses of the analyzed systems (Fig. 4). For example, the model can be used to analyze the harmonic attenuation factor in a hybrid active power filter with a single tuned passive filter. Some examples of frequency responses are shown in Fig 5. In a similar way it is possible to analyze the filter stability or sensitivity in the frequency domain.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 10, 10; 1109-1111
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Measurement and Analysis of Harmonics and Interharmonics in Output Waveforms of Frequency Inverter. Part II
Autorzy:
Bartman, J.
Powiązania:
https://bibliotekanauki.pl/articles/114230.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
interharmonics
inverter
power quality analyzer
measurements
Opis:
The paper discusses the measurement and analysis of the voltage and output power distortions of frequency inverter that supplies an induction motor. It covers basic information regarding frequency inverters and norms with definitions and descriptions of terms related to the measurement of harmonics and interharmonics. Moreover, it describes the problems that can occur while analyzing the signal when the inter-harmonics are present during the measurement. Exemplary results of measurements done with power quality analyzer in the laboratory have been presented.
Źródło:
Measurement Automation Monitoring; 2016, 62, 10; 325-328
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rozwój wzorców parametrów sieci energetycznej
Development of power network parameters standards
Autorzy:
Olencki, A.
Powiązania:
https://bibliotekanauki.pl/articles/151262.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
kalibrator mocy
wymuszalnik
parametry jakości energii
three phase power calibrator
phantom load
power quality parameters
Opis:
Omówiono fizyczne modele trójfazowej sieci energetycznej - wzorce parametrów sieci sinusoidalnej i niesinusoidalnej, spokojnej i niespokojnej. Przedstawiono rozwój wzorców parametrów sieci energetycznej i ich koncepcje, od pierwszego ROTEK 800 do najnowszego krajowego CALMET C300, oraz perspektywy ich dalszego rozwoju.
This article presents an idea of a physical models of three phase network - standards of sinusoidal and nonsinusoidal, stable and variable power network parameters named as the Power Calibrators or Electrical Power Standards. Terminology problems are discussed in section 1. Pyramid of standards for calibration of power network parameters meters and power quality analysers (Fig.1) and actual model power network with description of quantity and quality of energy (section 3) are described. There is presented progress of power network parameters standards and their concepts, from the first standards of sinusoidal and stable power network parameters ROTEK 800 [8] from USA and LUMEL SQ33 [9] from Poland to the newest standards of nonsinusoidal and variable power network parameters ROTEK 8100 [14] and FLUKE 6100A [15] from USA and CALMET C300 [20] from Poland. Progress analysis in construction of multiphase relay testers (section 5), advantages of their physical realisations and philosophy of their programming makes possible to design and introduce modern medium accuracy 0,05 and portable the C300 three phase power calibrator. Idea and construction of the new generation stationary single position meter test bench model LS3, as example of using the C300 calibrators is presented (Fig.6). The C300 calibrators, similar to SQ33 calibrators 20-ty years ago, are keeping our good position in the world market in medium accuracy power network parameters standards.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 12, 12; 993-996
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Measurement and Analysis of Harmonics and Interharmonics in Output Waveforms of Frequency Inverter. Part I
Autorzy:
Bartman, J.
Powiązania:
https://bibliotekanauki.pl/articles/114413.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
interharmonics
inverter
power quality analyzer
measurements
Opis:
The paper discusses the measurement and analysis of the voltage and output power distortions of frequency inverter that supplies an induction motor. It covers basic information regarding frequency inverters and norms with definitions and descriptions of terms related to the measurement of harmonics and interharmonics. Moreover, it describes the problems that can occur while analyzing the signal when the inter-harmonics are present during the measurement. Exemplary results of measurements done with power quality analyzer in the laboratory have been presented.
Źródło:
Measurement Automation Monitoring; 2016, 62, 10; 322-324
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Low power BIST
Autorzy:
Puczko, M.
Powiązania:
https://bibliotekanauki.pl/articles/114375.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
low power
BIST
test pattern generator
signature analyzer
test-per-scan
test-per-clock
power consumption
Opis:
In the last years designers have mainly concentrated on low power consumption in mobile computing devices and cellular phones. In this paper, new solutions for reducing the switching activity of BIST environment for the scan-organized Built-In Self-Test (BIST) architectures is presented. The key idea behind this technique is based on the design of a new structure of LFSR to generate more than one pseudo random bit per one clock pulse. Theoretical calculations were hardware verified in two digital system design environments: WebPACK ISE by Xilinx and Quartus II by Altera. Power consumption measure tools were Xilinx XPower and Altera PowerPlay Power Analyzer Tool. The practical verification covers the power consumption of the Test Pattern Generator (TPG) as well as the complete BIST. The obtained results are over a dozen percent better compared to similar works.
Źródło:
Measurement Automation Monitoring; 2015, 61, 7; 323-326
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Aspekty energetyczne monitorowania technologii spożywczej
Energetic aspects of food technology monitoring
Autorzy:
Bieliński, K. S.
Powiązania:
https://bibliotekanauki.pl/articles/2071439.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
bilansowanie
monitorowanie
media energetyczne
zarządzanie energią
efektywność energetyczna
balancing
monitoring
power media
power management
energy efficiency
Opis:
W artykule przedstawiono wybrane zagadnienia związane z wykorzystaniem monitorowania technologii spożywczych do wspomagania zarządzających w działaniu na rzecz podwyższania efektywności energetycznej, ekonomicznej i ekologicznej swoich technologii. W wyniku ciągłej kontroli wskaźników efektywnościowych i uzyskaniu szybkiej diagnozy stanu procesu technologicznego, zarządzający przedsiębiorstwami mogą planować szereg działań innowacyjnych i pro-oszczędnościowych, a także mogą dynamicznie weryfikować uzyskane efekty.
The paper discusses selected issues related to the use of food technolog monitoring to support the management acting for the increase of energ economic and ecological efficiency. As a result of continuous monitoring i efficiency indicators leading to rapid diagnosis of process technology, tł management can plan a series of innovative and pro-saving actions and ce also dynamically verify the results achieved.
Źródło:
Inżynieria i Aparatura Chemiczna; 2011, 3; 12-13
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sterowanie falownikiem napięcia w układzie cewek sprzężonych do zasilania pojazdów elektrycznych
Control of inverter for inductively powered electric vehicles
Autorzy:
Judek, S.
Karwowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/154075.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pojazd elektryczny
bezstykowy przesył energii
cewki sprzężone
rezonans
electric vehicle
contactless power transfer
inductive coupling
power converter
Opis:
Artykuł przedstawia analizę pracy oraz wybrane wyniki badania modelu laboratoryjnego układu bezstykowego przekazywania energii elektrycznej do pojazdów elektrycznych z wykorzystaniem cewek o słabym sprzężeniu magnetycznym. W szczególności omówiono warunki pracy układu w stanie rezonansu, dobór parametrów układu i metodę sterowania przekształtnika tranzystorowego w przypadku zmiany wielkości szczeliny powietrznej pomiędzy cewkami.
Most electrical equipment in common use is connected to the supply via plugs, flexible cables, slip rings, pantograph, etc. It can be useless in moist or explosion-endangered environment. This paper describes a technique, the contactless electrical energy transfer system, by which electrical energy may be transmitted through the large air gap. The transfer system is attractive especially for automatic battery charging stations and for energy supply of inductively powered electric vehicles and other movable consumers. In this case energy is transmitted via ironless transformer. Coupling between the windings is variables and depend on dimensions of air gap. The efficiency of system with large air gap (about 100 mm) can be considerably improved by using higher transmission frequencies in the range approximately 100 kHz. Large leakage inductances may be compensated also in resonance condition by adding capacitances to the windings. Paper presented analysis of power electronics converter with variable voltage frequency. These theoretical developments are compared with practical measurements from a prototype contactless system.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 4, 4; 60-63
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Weryfikacja doświadczalna analizatora jakości energii elektrycznej na statku m/s "Horyzont II"
Experimental verification of electrical power quality analyser on the ship m/s "Horyzont II"
Autorzy:
Tarasiuk, T.
Mindykowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/157618.pdf
Data publikacji:
2003
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
weryfikacja doświadczalna analizatora jakości
analizator jakości energii elektrycznej
experimental verification of electrical power
electrical power quality analyser
Opis:
W pracy przedstawiono strukturę i model fizyczny analizatora jakości energii elektrycznej opracowanego dla potrzeb energetyki okrętowej. Wspomniany model zrealizowany został z wykorzystaniem procesorów sygnałowych i przeszedł z wynikiem pozytywnym badania swoich właściwości w warunkach laboratoryjnych.Ostatecznej weryfikacji walorów użytkowych modelu dokonano na statku szkolno-badawczym Akademii Morskiej w Gdyni m/s "Horyzont II". W pracy przedstawiono wybrane przykłady przeprowadzonych badań.
Ii the paper the structure and physical model of the ships electrical power quality analyser has been presented. The above - mentioned model is based on the digital signals processing and it has been positively tested under the laboratoty conditions. The final verification of the operational properties of this device has been carried out on Gdynia Maritime University training ship m/v "Horizont II".
Źródło:
Pomiary Automatyka Kontrola; 2003, R. 49, nr 1, 1; 31-36
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of equivalent power system impedance in normal conditions
Wyznaczanie impedancji zastępczej systemu elektroenergetycznego w warunkach normalnych
Autorzy:
Małyszko, O.
Nowakowski, R.
Zeńczak, M.
Powiązania:
https://bibliotekanauki.pl/articles/156976.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
system elektroenergetyczny
moc zwarciowa
impedancja zastępcza
monitoring
power system
short-circuit power
equivalent impedance
on-line control
Opis:
The paper presents method of estimation of equivalent power system impedance. The method based on the correlation method which uses natural variability of the voltage level in the network nodes. To find the value of equivalent power system resistance and reactance the Lyapunov exponents were used. Equivalent impedance of power system is the base to determination of short-circuit currents and short-circuit power. On-line control over the short-circuit power in key nodes of power system might provide system dispatchers with an important piece of information.
Ważnym parametrem systemu elektroenergetycznego (SEE) jest poziom mocy zwarciowej w poszczególnych węzłach. Znajomość wartości mocy zwarciowej pozwala na określenie wartości spodziewanych prądów zwarciowych. Jest to niezbędne do prawidłowego doboru urządzeń w fazie projektowania systemu oraz do doboru nastaw automatyki zabezpieczeniowej. Moc zwarciowa zależy od impedancji zastępczej SEE. Wartość tej impedancji zależy od liczby generatorów, transformatorów, linii elektroenergetycznych oraz ich mocy, impedancji i układu połączeń między nimi. Wartość tej impedancji nie jest wielkością stałą w czasie. Zmiany mogą wynikać zarówno ze zmiany układu połączeń w systemie (zmiany krótkookresowe) jak też z rozwoju SEE (zmiany długookresowe). W artykule przedstawiono koncepcję wyznaczania impedancji zastępczej SEE w warunkach ruchowych. Przedstawiona metoda bazuje na zmienności poziomu napięcia w węzłach pomiarowych SEE spowodowanej przez losowe zmiany prądu obciążenia wynikające z losowej zmiany obciążenia. Zgodnie z proponowaną metodą do wyznaczenia impedancji systemu konieczny jest pomiar wartości skutecznej prądu, napięcia, mocy czynnej i dodatkowo wyznaczenie sumy wykładników Lapunowa.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 6, 6; 11-13
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energy and recycling forecasting. Part II. Resources for the secure life
Prognozowanie energii i recyklingu. Część II. Zasoby dla bezpiecznego życia
Autorzy:
Flizikowski, J.
Bieliński, K.
Powiązania:
https://bibliotekanauki.pl/articles/2071925.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
forecasting
waste
power engineering
prognozowanie
odpady
energetyka
Opis:
Both parts of the paper (I and II) show the assumptions, bases and models of recycling and energy development of society. The main premise is to organize knowledge focused on energy processors modelling, role of biological, fibrous and plastic wastes as energy, recycling and emission potential. On the one hand, the arrangement lies on steps' formalization in engineering prediction of energy and recycling: characteristics of utilities - idea and choice of technical specifications, on the other - on formalisms, models, calculations and simulations.
W obu częściach pracy przedstawiono założenia, podstawy i modele rozwoju energetycznego i recyklingowego społeczeństwa. Głównym założeniem jest uporządkowanie wiedzy w kierunku modelowania procesorów energii, roli odpadów biologicznych, włóknistych i plastikowych jako potencjałów energetycznych, recyklingu i emisji. Uporządkowanie polega z jednej strony na sformalizowaniu etapów inżynierii prognozowania energetyki i recyklingu: charakterystyki użytkowe - idea i dobór warunków technicznych. Z drugiej - na formalizmach, modelach, obliczeniach, symulacjach.
Źródło:
Inżynieria i Aparatura Chemiczna; 2014, 2; 67--68
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies