Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "low cost" wg kryterium: Wszystkie pola


Wyświetlanie 1-12 z 12
Tytuł:
Low-cost Monitoring System of a Sitting Posture
Autorzy:
Sieniawski, M.
Dimitrova-Grekov, T.
Klimowicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/114379.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
sitting position monitoring
RaspberryPi
graphical user interface
database
Opis:
The article presents a description of sitting posture monitoring system, built on Raspberry_Pi_3b, Tact Switch buttons, a prototype board and a rubber mat. RaspberryPi connected to the sensors communicated with a personal computer. This allows on the one hand to immediately inform the seated about the appearance of no symmetry of the position on the chair and managing the time of sitting and breaks on the other. The proposed system ensures identification of the degree of incorrect seating during work and gives the opportunity to improve the user's posture, which affects many topics related to health and work efficiency. System possesses a graphical user interface. During system operation, monitoring data is collected and can be used for further research towards an optimal impact on the user to get rid of the faulty sitting habits.
Źródło:
Measurement Automation Monitoring; 2018, 64, 1; 11-13
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Low-cost IR system for thermal characterization of electronic devices
Autorzy:
Kopeć, M.
Więcek, B.
Powiązania:
https://bibliotekanauki.pl/articles/114060.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
thermal impedance
Foster network
thermal time constants
temperature measurement
Opis:
In this article, a Low-cost measurement Infra-Red (IR) system for dynamic thermal testing of electronic devices is described. The element is powered by a step-function current and simultaneously temperature is measured by a fast single-detector IR head. The thermal impedance Zth(jω) is calculated using the Laplace transform and the Foster network is to get thermal time constants distribution.
Źródło:
Measurement Automation Monitoring; 2018, 64, 4; 103-107
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Low-cost, low-resolution IR system with super-resolution interpolation of thermal images for industrial applications
Autorzy:
Więcek, P.
Sankowski, D.
Powiązania:
https://bibliotekanauki.pl/articles/114076.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
Super-resolution
residual deep neural networks
image interpolation
Opis:
In this paper authors present application of deep neural networks for super-resolution interpolation of infrared images. A residual neural network with reduced number of layers was used. The transfer learning using RGB visual images was applied in this research. The validation of the network was performed for 32×24 and 160×120 pixels infrared images, with the up-sampling scale factors 2, 3, 4, 5 and 6. Monitoring of high temperature industrial processes like inductive heating and thermal hardening is the main application of proposed methods.
Źródło:
Measurement Automation Monitoring; 2018, 64, 4; 108-111
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Low-cost thermal scanner image enhancement by merging thermal and visual data
Autorzy:
Olbrycht, R.
Militowski, S.
Powiązania:
https://bibliotekanauki.pl/articles/114113.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
thermal scanner
multispectral
edge detection
thermal camera
image processing
Opis:
This paper demonstrates the application of different image processing techniques to process high resolution visual images and merge it with low resolution thermograms to improve its level of detail. The same idea is applied in commercially available thermal cameras (e.g. FLIR with MSX® technology). Low resolution thermograms considered in this paper were obtained from a thermal scanner with point infrared detector (Fig. 1) sensitive to long wavelength infrared spectral range. The proposed algorithms are Laplacian, Sobel operator, embossing and Gaussian differential blur (described in section 3). The authors processed 6 different thermograms to qualitatively assess obtained results. It was done in a statistical manner through a survey and revealed that both Sobel operator and embossing provided the most clear, detailed and unambiguous results (Fig. 5). Such algorithms may be applied for processing more channels in a multispectral, cost-effective system.
Źródło:
Measurement Automation Monitoring; 2015, 61, 6; 184-186
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A low cost depth sensor-based computer control system for the disabled people
Autorzy:
Połok, B.
Bilski, P.
Powiązania:
https://bibliotekanauki.pl/articles/114142.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
disabled people
human-computer interaction
Kinect
infrared sensors
Opis:
The paper presents the system for support interaction of disabled people using a low-cost computer module. The system is based on the Microsoft Kinect device. Its usability strongly depends on the designed software. The architecture of both software and hardware part of the system is discussed. The tests performed on human volunteers are presented as well. The conducted research confirms the usability of the system, showing its disadvantages and limitations.
Źródło:
Measurement Automation Monitoring; 2016, 62, 9; 292-296
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A low-cost embedded inertial measurement system for the monitoring of human movement
Autorzy:
Łazoryszczak, M.
Peryt, S.
Powiązania:
https://bibliotekanauki.pl/articles/114182.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
inertial measurement unit
embedded systems
human movement monitoring
sensor networks
Opis:
The paper presents a part of a prototype system for the monitoring of selected vital functions of humans and some preliminary results obtained from the device using implemented algorithm. The system consists of such essential modules like a microcontroller board, an inertial measurement unit and additional sensors. The main task of the device is human movement monitoring and detecting selected anomalies, e.g. fall or fainting. At the first stage, the movement classification was considered. The main movement type are walking, running and selected variants of transitions between different phases like standing up or going downstairs. The determining of the movement is based on the intuitive algorithm using raw data from accelerometers complemented by sensors like barometer and heart rate monitor. The algorithm utilizes automated multiscale-based peak detection and wavelet transform energy calculations. Finally, some further work directions and development possibilities are discussed.
Źródło:
Measurement Automation Monitoring; 2015, 61, 12; 542-544
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Niskokosztowe sensory MEMS w systemach nawigacji inercyjnej
Low-cost MEMS sensors for inertial navigation systems
Autorzy:
Sawicki, M.
Sondej, T.
Powiązania:
https://bibliotekanauki.pl/articles/158117.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
systemy pozycjonowania
nawigacja inercyjna
sensory MEMS
filtracja Kalmana
position systems
inertial navigation
MEMS sensors
Kalman filtering
Opis:
W artykule zaprezentowano system pozycjonowania zbudowany przy użyciu sensorów nawigacji inercyjnej (INS) oraz odbiornika GPS. Jako czujniki inercyjne zastosowano niskokosztowe, powszechnie dostępne akcelerometry i żyroskopy wykonane w technologii MEMS. Omówiono sposób kalibracji akcelerometru oraz metody przetwarzania sygnałów z sensorów MEMS. Przedstawiono również wyniki przeprowadzonych badań eksperymentalnych.
The paper presents a positioning system with GPS and inertial sensors. The system is based on commercial solutions described in [1, 3]. The designed system consists of a GPS receiver, a MEMS accelerometer, a MEMS gyroscope, an electronic compass and a pressure sensor. Data processing was carried out by use of a microcontroller with ARM Cortex-M3 core. Designated positions are recorded on a microSD memory card and transmitted by the UART interface according to the NMEA standard. The experimental tests consisting in driving on city roads were performed. The measurement results were recorded directly from the GPS receiver and the system output. Characteristic places such as a tunnel or railway traction were analysed. The results obtained show that MEMS sensors improve the accuracy of determining the position during short-term GPS signal outages. They allow setting the positions more accurately in difficult terrain such as dense urban areas and underground tunnels. In addition, application of low-cost sensors gives a possibility to use the system in popular car navigation systems or mobile phones.
Źródło:
Pomiary Automatyka Kontrola; 2012, R. 58, nr 8, 8; 701-703
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Methodology of Low Cost Rapid Manufacturing of Anatomical Models with Material Imitation of Soft Tissues
Autorzy:
Żukowska, Magdalena
Górski, Filip
Wichniarek, Radosław
Kuczko, Wiesław
Powiązania:
https://bibliotekanauki.pl/articles/103031.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
3D Printing
pre-operative support
biomedical engineering
druk 3D
wsparcie przedoperacyjne
inżynieria biomedyczna
Opis:
The pre-operative preparation of a surgeon is increasingly often extended to individual patient’s anatomical models depicting the affected organ and the existing lesion in relation to the surrounding structures (e.g. blood vessels). Among the models, there are models of the skeletal system, in which the FFF technology is used. The models of parenchymal organs are more difficult to reproduce due to the material limitations in the FFF technology, which is why alternative technologies such as PolyJet and SLA are used. Due to the high price of models, they are employed less frequently, especially in the Polish hospitals. The research presented in the article deals with the modification of the existing methodology of rapid pre-operative models production with the use of various low-budget rapid manufacturing techniques, which use materials of low hardness, similar to the human soft tissues. The aim was to create a methodology and determine the parameters of materials that allow for the cheap production of functional pre-operational aids.
Źródło:
Advances in Science and Technology. Research Journal; 2019, 13, 4; 120-128
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Low cost environment for rapid prototyping of control algorithms for mechatronic plants based on Microsoft Office Excel application
Autorzy:
Tutaj, A.
Augustyn, J.
Powiązania:
https://bibliotekanauki.pl/articles/114573.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
rapid prototyping
mechatronic system
Microsoft Office Excel
VBA
soft real time
Opis:
The paper presents a low cost rapid prototyping environment for control algorithm development based on Microsoft Excel program and a measurement and control board built on an ARM Cortex M core microcontroller. The solution is intended mainly for mechatronic devices. It provides tools for computer simulations and soft real time closed loop control experiments. An application to a fast and unstable mechatronic plant of an inverted pendulum on a cart is presented to show system capabilities.
Źródło:
Measurement Automation Monitoring; 2015, 61, 2; 43-46
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Niskobudżetowe metody skanowania 3D w tworzeniu wirtualnych ekspozycji muzealnych
Low-cost 3D scanning methods as tools for virtual heritage expositions
Autorzy:
Kęsik, J.
Montusiewicz, J.
Żyła, K.
Powiązania:
https://bibliotekanauki.pl/articles/158040.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
skanowanie 3D
światło strukturalne
obiekty muzealne
wirtualne ekspozycje muzealne
3D scanning
structured light
museum exhibits
virtual museum exhibitions
Opis:
W artykule przedstawiono propozycje zastosowania niskobudżetowych metod skanowania 3D do generowania wirtualnych ekspozycji muzealnych. Ekspozycja obejmuje modele eksponatów umieszczone w wizualizacji 3D ich naturalnego otoczenia. Wykorzystano metody bazujące na świetle strukturalnym (nie laserowe), bazujące na łatwo dostępnych sensorach (Microsoft Kinect, projektor kamera cyfrowa) i gotowych rozwiązaniach programistycznych. Metody dobrano pod kątem niskiego skomplikowania procedury skanowania oraz przydatności do realizowania przewidywanych zadań skanowania. Możliwość uzyskania zadowalającego wizualnie rezultatu została sprawdzona eksperymentalnie i oceniona pod kątem możliwości samodzielnego wykorzystania przez placówki muzealne.
The paper presents proposals for the use of low cost 3D scanning methods to generate virtual museum exhibitions. The exhibition includes models of exhibits placed in the 3D visualization of their natural environment. For the 3D scanning, methods based on structured light (not laser) were used, utilizing easy available sensors (Microsoft Kinect, projector, digital camera) and ready programming solutions. Two main scanning tasks were proposed: scanning of the exhibition environment and scanning of the exhibits themselves. For the first task there was chosen a method 1 which allowed for quick scanning of vast regions by utilization of Microsoft Kinect (Fig. 1.). For the second task there was selected a slower and more accurate method 2, utilizing a standard camera and projector with the aid of dedicated software David Laserscanner (Fig. 2.). The methods were chosen with regard to low complexity of the scanning procedure and the suitability to carry out the expected tasks of scanning (Fig. 3.). The possibility of obtaining a satisfactory result was experimentally verified (Fig. 4.) and evaluated in terms of the possibility of independent use by museums.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 8, 8; 664-667
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Low air consumption control in pneumatic positioning system
Energio-oszczędne sterowanie w pneumatycznych układach pozycjonujących
Autorzy:
Janiszowski, K.
Kuczyński, M.
Powiązania:
https://bibliotekanauki.pl/articles/154494.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
adaptacyjne sterowanie w torze otwartym
pozycjonowanie pneumatyczne
uklady ekonomiczne
adaptive open-loop control
low cost systems
pneumatic positioning
Opis:
The paper presents an idea of an open-loop control of a pneumatic positioning system consisting of a pneumatic cylinder, inexpensive measurement system and lour on-off switching valves. A strategy of two or three pulses on-off control trajectory for implementation of a determined piston displacement w ithout an overshoot is presented. Parameters for the control are determined by the application of an artificial neural nets that have to be trained before the application. A control error resultin g from open-loop control method can be removed in an adaptive way, proposed in the paper. The strategy is nearly time-optimum one and results in a short control time, quiet valves action and significant reduction of the compressed air consumption in comparison to other pneumatic positioning systems. The idea of this way of control was tested in many simulation experiments and in tests performed in a laboratory. It can be a basis for attractive, low-cost, economic positioning systems.
W pracy przedstawiona została metoda pozycjonowania w układzie złożonym z siłownika pneumatycznego, prostego układu pomiarowego oraz zespotu 4 zaworów przekaczających. Zasada sterowania w trybie otwartym ukladu opiera się na wypracowaniu sekwencji 2-3 pulsów sterujących zaworami, która prowadzi do przemieszczenia tłoka bez przeregulowania. Parametry określajace czas trwania pulsów są wyliczane za pomocą sztucznych sieci neuronowych. Powstająca odchyłka pozycjonowania jest usuwana poprzez adaptacyjne dopasowanie sekwencji sterowania. Metoda jest zbliżona do czaso-optymalnego sterowania i prowadzi do minimalnego zużycia powietrza oraz cichej pracy zaworów. Proponowana metoda została przebadana drogą symulacyjną oraz przeprowadzono pierwsze udane próby na stanowisku hadawczym.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 3, 3; 183-185
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Integrating coagulation and Fenton’s oxidation for pharmaceutical effluents treatment
Koagulacja połączona z utlenianiem Fentona w oczyszczaniu ścieków farmaceutycznych
Autorzy:
Martins, R. C.
Oliveira, A. C.
Quinta-Ferreira, R. M.
Powiązania:
https://bibliotekanauki.pl/articles/2073214.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pharmaceutical wastewater
heterogeneous Fenton's process
photo-Fenton process
low cost catalysts
biodegradability
ścieki farmaceutyczne
heterogeniczny proces Fentona
reakcja foto-Fentona
kataliza nisko-kosztowa
biodegradowalność
Opis:
Pharmaceutical industry produces complex and bio-refractory wastewater whose discharge throughout water courses constitutes an environmental danger. Although several works can be found handling with simulated pharmaceutical effluents, data reporting results gathered using actual wastewater is still scarce. This work reveals that Fe-Ce-O and red volcanic rock are interesting catalysts for dark and photo-Fenton. Furthermore, the light/H2O2 system showed interesting results and it is now being explored at the pilot scale by the pharmaceutical industry that provided the effluent.
Przemysł farmaceutyczny wytwarza złożone i bioodporne ścieki, których zrzut zwykła drogą stwarza zagrożenie dla środowiska. Pomimo tego, że kilka prac zajmuje się transportem symulowanych ciekłych odpadów farmaceutycznych, dane dotyczące rzeczywistych ścieków są wciąż skąpe. W prezentowanej pracy stwierdzono, że Fe-Ce-O i czerwona skała wulkaniczna są ciekawymi katalizatorami w reakcji foto-Fentona. Ponadto układ światło/H2O2 wykazał się interesującymi właściwościami i obecnie jest badany w skali pilotowej przy obróbce ścieków w przemyśle farmaceutycznym.
Źródło:
Inżynieria i Aparatura Chemiczna; 2015, 4; 174--177
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-12 z 12

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies