Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "liquid-liquid extraction" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Determination of chloramphenicol in milk powder using liquid-liquid cartridge extraction (Chem Elut) and liquid chromatography-tandem mass spectrometry
Autorzy:
Zawadzka, I.
Rodziewicz, L.
Powiązania:
https://bibliotekanauki.pl/articles/876762.pdf
Data publikacji:
2014
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
chloramphenicol
determination
milk powder
liquid-liquid extraction
liquid chromatography-tandem mass spectrometry
veterinary drug residue
Opis:
Background. The European Union prohibits the use of chloramphenicol (CAP) as a veterinary drug in food-producing animals. Nevertheless, CAP have been detected in milk products (liquid milk and milk powder). Therefore, it is necessary to develop sensitive methods for determining CAP residues in milk powder. Objective. The aim of this study was to develop and validate a confirmatory method for determination of CAP in milk powder. Material and methods. Chloramphenicol was determined in milk powder using LC-ESI-MS/MS in negative mode. After fat removing milk powder sample was extracted/cleaned-up with a Chem Elut extraction cartridge. Separation was achieved on a Phenomenex Luna C-18 column with acetonitrile-water as a mobile phase. The mass spectrometer was operated in multiple reaction monitoring mode (MRM). Four transitions were monitored m/z 321→152, 321→194, 321→257 (CAP) and 326→157 (IS CAP-d5). Results. Linearity, accuracy, precision, decision limit (CCa), detection capability (CCb) and ruggedness were determined for m/z 321→152. The mean relative recoveries (inter standard-corrected) of CAP from whole milk powder spiked at levels 0.1, 0.2, 0.3 and 0.6 mg/kg were in the range 95 - 103%. Relative standard deviation (RSD%) of recoveries at all spiked levels were less than 14%. RSDs within-laboratory reproducibility calculated at fortification of 0.3 mg/kg was less than 16%. CCa and CCb were below 0.1 mg/kg. Conclusions. The developed LC-MS/MS method allows the determination of CAP in milk powder. The method was validated according to the Commission Decision No. 2002/657/EC requirements. This method can be applied to determination CAP in whole and skim milk powder.
Wprowadzenie. Unia Europejska zabroniła stosowania chloramfenikolu (CAP) jako leku weterynaryjnego u zwierząt, których produkty są przeznaczone do spożycia. Pomimo tego, CAP jest wykrywany w produktach mleczarskich (mleko i mleko w proszku). Cel. Celem badań było opracowanie i zwalidowanie metody pozwalającej na oznaczanie CAP w mleku w proszku. Materiał i metoda. CAP był oznaczany w mleku w proszku metodą LC-ESI-MS/MS w trybie jonizacji ujemnej. Po usunięciu tłuszczu próbka była ekstrahowana/oczyszczana za pomocą ekstrakcyjnych kolumienek Chem Elut. Do rozdziału CAP stosowano kolumnę chromatograficzną Phenomenex Luna C-18. Fazę ruchomą stanowił acetonitryl/woda. Spektrometr masowy pracował w trybie monitorowania wybranych reakcji (MRM). Cztery przejścia były monitorowane m/z 321→152, 321→194, 321→257 (CAP) i 326→157 (IS CAP-d5). Wyniki. Liniowość, odzysk, precyzja, limit decyzyjny (CCa), zdolność wykrywania (CCb) i odporność metody zostały wyznaczone dla 321→152. Średni względny odzysk CAP z mleka pełnego był wyznaczony dla próbek wzbogaconych na poziomach odpowiadających 0.1, 0.2, 0.3 i 0.6 mg/kg i mieściły on się w zakresie 95 - 103%. Względne odchylenie stadardowe (RSD%) dla wszystkich poziomów było mniejsze niż 14%. Powtarzalność wewnątrzlaboratoryjna (RSDs) obliczona dla poziomu wzbogacenia 0.3 mg/kg była mniejsza niż 16%. CCa and CCb były poniżej 0.1 mg/kg. Wnioski. Opracowana metoda LC-ESI-Ms/MS pozwala oznaczyć CAP w mleku w proszku. Metoda została zwalidowana zgodnie z wymaganiami decyzji Komisji nr 2002/657/WE. Metoda może być stosowana do mleka pełnego i odtłuszczonego.
Źródło:
Roczniki Państwowego Zakładu Higieny; 2014, 65, 3
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimisation and validation of the analytical procedure for the determination of acrylamide in coffee by LC-MS/MS with SPE clean up
Autorzy:
Gielecinska, I.
Mojska, H.
Powiązania:
https://bibliotekanauki.pl/articles/875236.pdf
Data publikacji:
2013
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
optimization
validation
analytical procedure
determination
acrylamide
coffee
liquid chromatography
tandem mass spectrometry method
solid-phase extraction
Opis:
Background. Numerous studies have demonstrated acrylamide to be both neurotoxic and carcinogenic. At present it is widely recognised that acrylamide is mainly formed through the Maillard reaction from free asparagine and reducing sugars. The major sources of dietary acrylamide are potato products, processed cereals and coffee. Objective. To optimise and validate an analytical method for determining acrylamide in coffee by liquid chromatography and tandem mass spectrometry analysis (LC/MS/MS) using SPE clean-up. Material and methods. Analytical separation of acrylamide from roasted coffee was performed by liquid chromatography using a Hypercarb column followed by LC/MS/MS analysis, with 2,3,3–d3 acrylamide as an internal standard. The method was based on two purification steps: the first with hexane and Carrez solutions in order to remove of fat and to precipitate proteins, respectively; and the second with a solid-phase extraction (SPE) column which proved to be efficient in the elimination of the main chromatographic interferences. Results. Limit of quantification (LOQ) for measuring acrylamide in coffee was 50 μg/kg. The described method demonstrates satisfactory precision (RSD = 2.5%), repeatability (RSD = 9.2%) and accuracy (mean recovery – 97.4%). Conclusions. Our results confirm that LC-MS/MS with SPE clean-up is selective and suitable for determination of acrylamide in coffee. Indeed, this method meets the criteria of EU Commission Recommendations (No. 2007/331/EC and No. 2010/307/EU), on the monitoring of acrylamide levels in food.
Wprowadzenie. W licznych badaniach wykazano, że akryloamid jest związkiem neurotoksycznym i kancerogennym. Obecnie wiadomo, że akryloamid w żywności powstaje w wyniku reakcji Maillarda pomiędzy wolną asparaginą a cukrami redukującymi. Głównym źródłem akryloamidu w diecie człowieka są produkty ziemniaczane, przetwory zbożowe oraz kawa. Cel. Optymalizacja warunków procedury analitycznej i walidacja metody oznaczania zawartości akryloamidu w różnych rodzajach kawy techniką wysokosprawnej chromatografii cieczowej sprzężonej z tandemową spektrometrią mas (LC-MS/ MS) z wykorzystaniem ekstrakcji do fazy stałej (SPE). Materiał i metody. Akryloamid w kawie palonej oznaczono na kolumnie Hypercarb metodą chromatografii cieczowej sprzężonej z tandemową spektrometrią mas (LC-MS/MS). Jako wzorzec wewnętrzny zastosowano 2,3,3-d3 akryloamid. W metodzie tej zastosowano 2 stopniowy proces oczyszczania próbki: w pierwszej kolejności usunięto tłuszcz heksanem oraz strącono białka poprzez dodanie roztworów Carreza, a następnie wykorzystując ekstrakcję do fazy stałej (SPE) próbkę oczyszczono z pozostałych zanieczyszczeń, które mogłyby mieć wpływ na wynik w czasie analizy chromatograficznej. Wyniki. Granica oznaczalności metody LC-MS/MS oznaczania akryloamidu w kawie wynosi 50 μg/kg. Opracowana metoda charakteryzuje się dobrą precyzją (RSD = 2,5%), powtarzalnością (RSD = 9,2%) oraz dokładnością (średni odzysk = 97,4%). Wnioski. Wyniki walidacji potwierdzają selektywność i przydatność opracowanej metody do oznaczania akryloamidu w kawie. Opracowana metoda LC-MS/MS spełnia wymagania zaleceń Komisji Unii Europejskiej (2007/331/EC i 2010/307/ EU) w sprawie monitorowania poziomów akryloamidu w żywności.
Źródło:
Roczniki Państwowego Zakładu Higieny; 2013, 64, 2
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oznaczanie cukrow typu rafinozy w nasionach roslin straczkowych metoda wysokocisnieniowej chromatografii cieczowej - HPLC
Autorzy:
Kosson, R
Powiązania:
https://bibliotekanauki.pl/articles/875743.pdf
Data publikacji:
1992
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
analiza chemiczna
fasola
chromatografia cieczowa
zywnosc
nasiona
rosliny straczkowe
weglowodory
ekstrakcja
chromatografia cieczowa wysokosprawna
bob
oznaczanie
chemical analysis
bean
liquid chromatography
food
seed
leguminous plant
hydrocarbon
extraction
high performance liquid chromatography
broad bean
determination
Opis:
Opisano metodę ekstrakcji galaktocukrów gazotwórczych z nasion fasoli i bobu oraz ich ilościowego oznaczania techniką HPLC. Określono m.in. skład mieszaniny ekstrakcyjnej, sposób oczyszczania i skład fazy ruchomej.
A method was developed for the determination of galactosugars: raflinose, stachiose and verbas-cose, In bean and broad bean seeds by high-pressune liquid chromatography. The effect of various concentrations of the ethanolic extraction solvent and of other solutions (methanol and acetonitrile) on the effectiveness of sugar extraction from bean was investigated. The optimal composition of the mobile phase was established. It was found that the effectiveness of raflinose and stachiose extraction from bean seeds was highest when 40-60% ethanol was the extraction solvent, and when the proportion of bean to the extraction solvent by weihgt was 2:25. The presented HPLC technique, as compared with gas chromatography, allows for threefold shortening of the duration of one chromatographic analysis.
Źródło:
Roczniki Państwowego Zakładu Higieny; 1992, 43, 2; 179-185
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies