Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "air humidity" wg kryterium: Temat


Tytuł:
Examining technical solutions for a prototype of a solar-air collector
Autorzy:
Leśny, J.
Panfil, M.
Urbaniak, M
Schefke, R.
Powiązania:
https://bibliotekanauki.pl/articles/298008.pdf
Data publikacji:
2015
Wydawca:
Uniwersytet Warmińsko-Mazurski w Olsztynie
Tematy:
solar air collector
air humidity
evaporation potential
Opis:
The research was conducted in the framework of the project known as „Coupon for innovations - support for the smallest companies”, endorsed by the Polish Agency for the Development of Business, and it had the following objectives: to assess the efficiency of the collector and reliability of the applied parameters such as the force of warm air blast, temperature increase depending on the intensity of solar radiation and the angle of the collector setup, influence of ambient temperature on the collector’s efficiency and heat loss, the quantity of relative humidity reduction correlative with the heating up of the flowing air. Collector in a standard installation position - on a vertical wall. The assessed solar air collector was exposed to solar radiation and the following parameters were measured in the course of study: intensity of solar radiation falling on a vertical surface and on the collector’s surface (the collector was installed in vertical position, which is a standard installation method), temperature and velocity of air flowing into the collector as well as temperature and velocity of air flowing out of the device. The studies indicate that already at the radiation value of 100 W m-2 the collector worked efficiently and heated up the flowing air by about 5oC. This temperature increased together with radiation and reached the value of 20oC at the radiation of 800 W m-2. The analysis of the collector’s efficiency showed that during its work (proper temperature and radiation) the efficiency remained at a satisfactory level from 42 to 46%.
Źródło:
Technical Sciences / University of Warmia and Mazury in Olsztyn; 2015, 18(2); 125-135
1505-4675
2083-4527
Pojawia się w:
Technical Sciences / University of Warmia and Mazury in Olsztyn
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Variations in weather on the East and West coasts of South Spitsbergen, Svalbard
Autorzy:
Maciejowski, Wojciech
Michniewski, Adam
Powiązania:
https://bibliotekanauki.pl/articles/2051847.pdf
Data publikacji:
2007
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Arctic
Spitsbergen
air temperature
air humidity
foehn effects
Źródło:
Polish Polar Research; 2007, 2; 123-136
0138-0338
2081-8262
Pojawia się w:
Polish Polar Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przebieg roczny wilgotności względnej w Arktyce Norweskiej w okresie 1971-2000
Annual course of relative air humidity in the Norwegian Arctic from 1971 to 2000
Autorzy:
Araźny, A.
Powiązania:
https://bibliotekanauki.pl/articles/260941.pdf
Data publikacji:
2003
Wydawca:
Stowarzyszenie Klimatologów Polskich
Tematy:
wilgotność powietrza
Arktyka Norweska
air humidity
Norwegian Arctic
Opis:
The paper presents the analysis of the spatial variability of relative humidity in the Norwegian Arctic during the year (Fig.1, Table 2) for 6 meteorological stations (Table 1). We determined the frequency of relative humidity according intervals (Fig. 2) and examined its connection with atmospheric circulation indices (Table 3, Fig. 3). In the Norwegian Arctic 3 types of courses of the relative humidity have been distinguished on the basis of mean monthly values, amplitudes and occurrence frequency in distinguished intervals: 1) very wet - characterised by monthly and annual mean values of the relative humidity higher than 80%, small annual amplitudes up to 10%. This type includes the stations Bjornoya, Hopen i Jan Mayen. During the year at these stations very wet air dominates (236, 218 and 175 days, respectively). 2) wet - characterised by large annual amplitudes over 10%. Mean monthly values exceeding 80% occur only in summer and early autumn. This type occurs at the stations Hornsund and Ny-Alesund. At these stations wet air is the most frequent: 181 and 141 days during the year, respectively. 3) moderately wet - characterised by even level in every month below 80%, very small annual amplitude up to 5%. This type occurs at Svalbard Lufthavn where wet (171 days) and moderately dry (135 days) air is the most frequent.
Źródło:
Problemy Klimatologii Polarnej; 2003, 13; 107-115
1234-0715
Pojawia się w:
Problemy Klimatologii Polarnej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Relative air humidity and saturation deficit in Leba
Charakterystyka wilgotności względnej powietrza oraz niedosytu wilgotności w Łebie
Autorzy:
Baranowski, D.
Powiązania:
https://bibliotekanauki.pl/articles/85179.pdf
Data publikacji:
2010
Wydawca:
Akademia Pomorska w Słupsku
Tematy:
air humidity
saturation deficit
Leba town
atmosphere
moisture deficit
Opis:
The main aim of the paper was to determine the most important features of air humidity in Łeba in the years 1976-2005. The average daily values of relative air humidity (RH) and saturation deficit (SD) from the meteorological station in Łeba were used as basic data for the survey. After initial estimation of dispersion parameters and asymmetry of distribution, these values were calculated for annual and multi-annual periods. The survey findings showed that in Łeba the humidity of air in the analysed period was relatively high (with mean annual RH and SD values – 82.8% and 2.1 hPa respectively). The highest mean air humidity is normally reported in winter months (with maximum in December), while relatively low humidity values are recorded in the warm half-year (Apr.-Sep.). The provided analysis of long-term variability in monthly and annual averages has shown a decreasing trend of air humidity in the region of Łeba. Such conclusion is proved by statistically significant tendencies: growing of moisture deficit and dropping of relative air humidity. The greatest fall in air humidity within the 30-yr period was found in April; while rise was noted only in May. The greatest diversification of mean monthly air humidity values are typical for the period between April and July; the most stable higric conditions are usually recorded in December.
Opracowanie prezentuje charakterystykę warunków wilgotnościowych w Łebie na podstawie analizy średnich miesięcznych i rocznych wartości wilgotności względnej powietrza oraz niedosytu wilgotności w latach 1976-2005. Przeprowadzona analiza zmienności warunków wilgotnościowych w badanym okresie wskazuje na stopniowe wysuszanie powietrza w rejonie Łeby. Świadczą o tym statystycznie istotne tendencje: spadkowa wilgotności względnej oraz wzrostowa niedosytu wilgotności. Największy spadek wilgotności powietrza w Łebie na przestrzeni 30 lat odnotowano w lutym, kwietniu, sierpniu oraz wrześniu przy jednoczesnym małym wzroście nasycenia powietrza parą wodną w miesiącach wiosennych. Największą zmiennością wilgotności powietrza z roku na rok wyróżnia się okres zimowy (z maksimum w lutym); najbardziej stabilne warunki higryczne występują najczęściej późną jesienią.
Źródło:
Baltic Coastal Zone. Journal of Ecology and Protection of the Coastline; 2010, 14
1643-0115
Pojawia się w:
Baltic Coastal Zone. Journal of Ecology and Protection of the Coastline
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Temperatura i wilgotność powietrza w warstwie przygruntowej w okresie wegetacyjnym w różnie uwilgotnionych siedliskach łąkowych
Air temeperature and air humidity in the above-ground layer in the growing season in differently moistured meadow sites
Autorzy:
Roguski, W.
Kasperska-Wołowicz, W.
Łabędzki, L.
Smarzyńska, K.
Powiązania:
https://bibliotekanauki.pl/articles/337697.pdf
Data publikacji:
2005
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
siedlisko łąkowe
temperatura i wilgotność powietrza
air humidity
air temperature
meadow site
Opis:
Badania prowadzono w rejonie Bydgoszczy w trzech zróżnicowanych siedliskach łąkowych: wilgotnym na madzie średniej w dolinie Wisły (Grabowo), wilgotnym okresowo suchym na glebie torfowo-murszowej (Frydrychowo) oraz suchym na glebie murszowej (Prądki) - oba w dolinie Noteci. Wyniki badań porównywano z uzyskanymi w Bydgoszczy w siedlisku suchym na glebie brunatnej. Pionowy rozkład i przebieg dzienny badanych elementów meteorologicznych były różne w badanych siedliskach. Średnie dobowe wartości ciśnienia pary wodnej i niedosytu wilgotności powietrza obliczane z trzech terminów pomiarów różniły się od obliczanych na podstawie czterech terminów, zwłaszcza w siedliskach łąkowych. Średnia dobowa wartość niedosytu wilgotności powietrza zależała od metody obliczania; dotyczy to szczególnie częstości i terminów wykonywania poszczególnych pomiarów meteorologicznych w ciągu doby. Zróżnicowanie dobowego przebiegu temperatury i wilgotności powietrza oraz ich pionowego rozkładu powoduje, że relacje między parowaniem z odkrytego lustra wody i średnią dobową wilgotnością powietrza są różne w badanych siedliskach. Zróżnicowane wartości dobowe, ich przebieg oraz rozkład pionowy określany różnymi metodami powodują, że współczynnik higrometryczny (stosunek parowania z odkrytego lustra wody do niedosytu wilgotności powietrza) osiąga różne wartości. Współczynnik ten w zależności liniowej osiąga najmniejsze wartości w siedlisku suchym na glebie brunatnej, zaś największe w siedlisku wilgotnym okresowo suchym na glebie torfowo-murszowej.
Studies were carried out in three different grassland sites near Bydgoszcz: wet site in fluvial soil in the Vistula River valley (Grabowo), wet periodically dry site in peat-moorsh soil (Frydrychowo) and dry site in mineral-moorsh soil (Prądki), both in the Noteć River valley. Measurements carried out in the dry site in mineral soil (Bydgoszcz) were used for comparison. Vertical distribution and daily course of examined meteorological factors were different in the examined sites. Mean daily water vapour pressure and water vapour pressure deficit calculated from three measurements at 7 a.m., 1 p.m. and 7 p.m. CET differed from those calculated from four measurements, especially in dry sites. It appeared necessary to include also a measurement at 1 a.m. or to use data from automatic stations. Mean daily water vapour pressure deficit depended on adopted calculation method, especially on the frequency and on terms of particular measurements during twenty-four hours. Differentiation of the daily courses of temperature and air humidity and their vertical distribution caused that relationships between water evaporation and mean daily air humidity were different in the examined sites. The values, daily courses and vertical distribution diversity of water vapour pressure deficit resulted in differences of the higrometric coefficient (the ratio of water evaporation to vapour pressure deficit). The coefficient, in the linear relationship, was the lowest in the dry site in mineral soil, and the highest in wet periodically dry one in peat-moorsh soil.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2005, 5, 2; 111-130
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Raschetnyjj metod opredelenija rezhimov oroshenija s ispolzovaniem klimaticheskikh pokazatelejj
Calculating method for defining irrigation modes using climatic indices
Autorzy:
Karaiev, A.
Susho, S.
Gorbach, N.
Powiązania:
https://bibliotekanauki.pl/articles/76631.pdf
Data publikacji:
2015
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
calculation method
watering
irrigation
air temperature
relative air humidity
precipitation
climate index
Źródło:
Motrol. Motoryzacja i Energetyka Rolnictwa; 2015, 17, 9
1730-8658
Pojawia się w:
Motrol. Motoryzacja i Energetyka Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Correlation between sunshine duration and global solar radiation in South-Eastern Romania
Autorzy:
Paltineanu, C.
Mihailescu, I.F.
Torica, V.
Albu, A.N.
Powiązania:
https://bibliotekanauki.pl/articles/24665.pdf
Data publikacji:
2002
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
global solar radiation
Romania
air temperature
air humidity
sunshine duration
extra-terrestrial radiation
Źródło:
International Agrophysics; 2002, 16, 2
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dobowa zmienność temperatury i wilgotności powietrza na wysokości 2,0 i 0,5 m w siedlisku wilgotnym w dolinie Noteci i siedlisku suchym w Bydgoszczy
Daily variability of air temperature and humidity at a height of 2.0 m and 0.5 m in the wet site of the Noteć river valley and the dry site in Bydgoszcz
Autorzy:
Roguski, W.
Łabędzki, L.
Kasperska-Wołowicz, W.
Powiązania:
https://bibliotekanauki.pl/articles/338647.pdf
Data publikacji:
2004
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
siedlisko glebowo-wodne
temperatura powietrza
wilgotność powietrza
air humidity
air temperature
soil-water site
Opis:
W pracy przestawiono analizę dobowej zmienności temperatury i wilgotności powietrza w okresie wegetacyjnym w dwóch siedliskach w rejonie Bydgoszczy. Wykazano duże zróżnicowanie wartości, przebiegu w ciągu doby i rozkładu pionowego w przyziemnej warstwie atmosfery: temperatury, wilgotności względnej, ciśnienia pary wodnej i niedosytu wilgotności powietrza. Przyczyną tego zróżnicowania jest uwilgotnienie siedliska glebowo-wodnego oraz pokrywa roślinna. Zmienność temperatury i wilgotności powietrza w ciągu doby i ich pionowy rozkład powodują, że zależności parowania wody od średniego dobowego niedosytu wilgotności powietrza są różne w badanych siedliskach.
The paper presents analyses of the variability of air temperature and humidity in the growing season at two sites in the Bydgoszcz region. The values, daily course and vertical distribution of air temperature, relative humidity, vapour pressure and vapour pressure deficit were different in the near ground layer of atmosphere. The moisture of soil-water site and plant cover are the reasons of this variability. Daily variability of air temperature and humidity and their vertical distribution are responsible for different relationships between evapotranspiration and vapour pressure deficit in the studied sites.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2004, T. 4, z. 2a; 137-156
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowanie wilgotności względnej powietrza w budynkach - możliwości i ograniczenia programu CONTAMW 3.0
Modeling of relative humidity in buildings-potential and limitations OF CONTAMW 3.0 software
Autorzy:
Mijakowski, M
Sowa, J
Powiązania:
https://bibliotekanauki.pl/articles/362406.pdf
Data publikacji:
2011
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
wilgotność powietrza wewnętrznego
obliczenia przepływów powietrza
CONTAM
inside air humidity
calculation of air flow
Opis:
W artykule przedstawiono możliwości wykorzystania programu CONTAMW 3.0 do modelowania procesów kształtujących wilgotność względną powietrza w pomieszczeniach. Wykazano, że program stworzony do modelowania procesów migracji zanieczyszczeń w wielostrefowych budynkach może być z powodzeniem wykorzystany do modelowania następujących procesów: emisji pary wodnej, transportu adwekcyjnego, kondensacji oraz sorpcji pary wodnej w materiałach wyposażenia wnętrz. Omówiono także ograniczenia programu związane przede wszystkim z brakiem modułu obliczeń cieplnych. Jako ilustrację możliwości programu CONTAMW 3.0 wykonano przykładowe obliczenia wilgotności względnej powietrza w wybranych pomieszczeniach budynku wielorodzinnego dla dwóch systemów wentylacji mechanicznej wywiewnej (ze stałym strumieniem powietrza oraz ze strumieniem sterowanym wilgotnością powietrza).
The paper presents the possibilities of utilisation computer programme CONTAMW 3.0 for modelling the processes creating the relative humidity indoors. It has been presented that software developed originally for modelling migration of pollutants in multizone buildings can be successfully used for modelling following processes: water vapour emission, advective transport of water vapour with air, condensation and moisture sorption in building materials. Limitations of the software, mainly lack of module responsible for thermal analysis, have also been discussed. As an illustration of CONTAM 3.0 capabilities, the example calculations of relative humidity in selected spaces of multifamily residential building for two options of mechanical exhaust ventilation systems (with constant air volume and with humidity driven control) have been performed.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2011, T. 6, nr 1, 1; 79-84
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowanie sterowania optymalnego temperaturą i wilgotnością powietrza w pomieszczeniu budynku i klimatyzacją
Modeling of optimal simultaneus control of indoor air temperature and humidity inside air-conditioned buildings
Autorzy:
Dzieniszewski, W.
Powiązania:
https://bibliotekanauki.pl/articles/363062.pdf
Data publikacji:
2005
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
klimatyzacja
sterowanie temperaturą powietrza
sterowanie wilgotnościa powietrza
air-condition
air humidity control
temperature control
Opis:
Przedstawiono sformułowanie i ogólne rozwiązanie zadania optymalnego sterowania temperaturą i wilgotnością powietrza wewnętrznego, zilustrowane przykładem liczbowym. Sterowanie obejmuje określony przedział czasu użytkowania pomieszczenia, w którym występuje intensyfikacja oddziaływań cieplnych i wilgotnościowych pochodzących od wewnętrznych i zewnętrznych źródeł środowiska.
Formulation and solution of the optimal control of indoor air temperature and humidity is presented, A room with air-conditioning system is subjected to combinedheat and moisture effect arising from disturbances of various intemal and extemal environrnental sources.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2005, T. 1; 39-54
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Temperature gradients as a main cause of Ixodes tick emergence from the litter
Autorzy:
Alekseev, A.N.
Dubinina, H.V.
Powiązania:
https://bibliotekanauki.pl/articles/840470.pdf
Data publikacji:
1998
Wydawca:
Polskie Towarzystwo Parazytologiczne
Tematy:
temperature
Ixodes
litter
air humidity
light
Ixodes persulcatus
soil temperature
Ixodes ricinus
tick
Źródło:
Annals of Parasitology; 1998, 44, 3
0043-5163
Pojawia się w:
Annals of Parasitology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rola cyrkulacji atmosferycznej w kształtowaniu warunków higrycznych w dorzeczu górnej Wisły
Air humidity conditions in the upper Vistula river dasin in relation to atmospheric circulation
Autorzy:
Wypych, A.
Czekierda, D.
Powiązania:
https://bibliotekanauki.pl/articles/338286.pdf
Data publikacji:
2012
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
cyrkulacja atmosferyczna
dorzecze górnej Wisły
wilgotność powietrza
air humidity
atmospheric circulation
southern Poland
Opis:
Wilgotność powietrza, charakteryzująca zawartość pary wodnej w powietrzu, jest elementem odgrywającym istotną rolę w procesach meteorologicznych zachodzących w atmosferze. Głównym celem opracowania jest ocena zróżnicowania warunków higrycznych w dorzeczu górnej Wisły na tle cyrkulacji atmosferycznej. Wykorzystano dane dobowe z lat 1981-2010, pochodzące z 9 stacji synoptycznych. Przedstawiono zróżnicowanie w czasie i przestrzeni wilgotności właściwej i niedosytu wilgotności powietrza. Oddziaływanie czynnika cyrkulacyjnego określono wykorzystując kalendarz sytuacji synoptycznych w dorzeczu górnej Wisły T. Niedźwiedzia. Z przeprowadzonej analizy wynika istotna zależność zawartości pary wodnej w powietrzu, zwłaszcza w ujęciu sezonowym, od aktualnej sytuacji synoptycznej. Stwierdzono również duże zróżnicowanie przestrzenne warunków higrycznych w określonych warunkach cyrkulacyjnych. Najbardziej niekorzystne warunki higryczne, prowadzące m.in. do wysuszenia przypowierzchniowych warstw gleby, panują w sytuacji antycyklonalnej z napływem mas powietrza z południowego zachodu. Dobra zależność warunków wilgotnościowych od cyrkulacji atmosferycznej jest widoczna przede wszystkim w chłodnej połowie roku. W miesiącach letnich sytuacja jest bardziej skomplikowana, co może również świadczyć o istotnym wpływie czynnika radiacyjnego oraz lokalnych warunków środowiskowych.
Air humidity, describing the amount of water vapour in the atmosphere, is an element which plays an important role among the meteorological processes which are taking place within the atmosphere. The principal aim of this study is to examine the atmospheric circulation conditionings of air humidity differentiation in the upper Vistula river basin (southern Poland). Research was based on data for the period 1981-2010 coming from 9 meteorological stations. The temporal and spatial differentiation of air humidity in relation to atmospheric circulation patterns was examined by analysis of specific humidity and saturation deficit values. The circulation factor was determined by the synoptic situation types classification by T. Niedźwiedź. Analysis conducted to confirm the impact of atmospheric circulation over Southern Poland on humidity conditions and their spatial differentiation showed the significant relationship seasonally dependant. The most difficult hygric conditions, leading to drying up of subsurface soils, are connected with south-west air mass advection and the high pressure system over southern Poland. The relationship is much stronger in the cool half of the year whereas during summer months also radiation and local, environmental conditions play an important role and modify air humidity.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2012, 12, 2; 351-364
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Environmental factors-induced stomatal signalling
Autorzy:
Merilo, E.
Laanemets, K.
Xue, S.
Margna, L.
Schroeder, J.
Brosche, M.
Kollist, H.
Powiązania:
https://bibliotekanauki.pl/articles/80937.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
conference
environmental factor
stomatal signalling
signal transduction
stomatal conductance
carbon dioxide
air humidity
Źródło:
BioTechnologia. Journal of Biotechnology Computational Biology and Bionanotechnology; 2013, 94, 2
0860-7796
Pojawia się w:
BioTechnologia. Journal of Biotechnology Computational Biology and Bionanotechnology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie warunków wilgotnościowych w ogrzewanych tuczarniach między sezonami przejściowymi wiosennym i jesiennym
Comparison of air humidity conditions in heated fattening houses between the transitional seasons of spring and autumn
Autorzy:
Żelazny, H.
Powiązania:
https://bibliotekanauki.pl/articles/239013.pdf
Data publikacji:
2008
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
wilgotność powietrza
pomieszczenie
tuczarnia
budynek inwentarski
livestock building
piggeries
fattened pig
air humidity
Opis:
Celem badań było porównanie między sezonami przejściowymi, to jest wiosennym i jesiennym, warunków wilgotnościowych występujących w ogrzewanych pomieszczeniach przeznaczonych do produkcji żywca wieprzowego. W pięciu identycznych tuczarniach raz w każdym z trzech miesięcy okresów przejściowych mierzono temperaturę i wilgotność względną powietrza. Na podstawie tych parametrów oraz temperatury i wilgotności względnej powietrza zewnętrznego obliczano różnicę ciśnień pary wodnej po obu stronach przegród zewnętrznych. Zarówno wilgotność względna powietrza wewnętrznego, jak i różnica ciśnień pary wodnej były większe jesienią, stąd sezon ten uznano za bardziej niekorzystny z uwagi na możliwość wystąpienia zagrożenia wynikającego z zawilgocenia materiałów budowlanych.
The study aimed at comparing the conditions of air humidity in the heated piggeries for fatteners during two transitional periods, i.e. the spring and autumn seasons. In five identical pig fattening buildings the air temperature and relative humidity were measured once in each of the three months during transitional seasons. On the basis of measured air parameters as well as the temperature and relative humidity of the ambient air, the differences in water vapour pressure on both sides of the external building partitions were determined. Both, the relative humidity of inside air, and the difference in water vapour pressure, were higher in autumn. Thus, this season was acknowledged as more unfavorable because of the possible potential threat resulted from the moistening of building materials.
Źródło:
Problemy Inżynierii Rolniczej; 2008, R. 16, nr 1, 1; 167-174
1231-0093
Pojawia się w:
Problemy Inżynierii Rolniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie charakterystyk przepływowych higrosterowalnych nawiewników powietrza montowanych w przegrodach zewnętrznych
Testing the flow characteristics of externally mounted humidity controlled air transfer devices
Autorzy:
Owczarek, Z.
Powiązania:
https://bibliotekanauki.pl/articles/182843.pdf
Data publikacji:
2008
Wydawca:
Instytut Techniki Budowlanej
Tematy:
nawiewnik powietrza
nawiewnik higrosterowany
nawiewnik okienny
przepływ powietrza
metoda badań
wilgotność powietrza
wyniki badań
humidity controlled air transfer device
air flow
flow characteristics
air humidity
Opis:
Ponieważ w Polsce nie ma zorganizowanego stanowiska do badania charakterystyk przepływowych nawiewników higrosterowalnych odpowiadającego wymaganiom PN-EN 13141-9, w artykule zaproponowano metodę badania w warunkach izotermicznych z wykorzystaniem istniejących stanowisk Laboratorium Izolacji Termicznych ITB. Metoda ta różni się od opisanej w PN-EN 13141-9 tym, iż najpierw określa się stopień otwarcia nawiewników w komorze klimatycznej w zależności od wilgotności względnej powietrza, a następnie mierzy strumień przepływającego powietrza przy wyznaczonych wcześniej stopniach otwarcia i ustalonej różnicy ciśnienia. W artykule przedstawiono wyniki badań nawiewników higrosterowalnych i dokonano ich oceny z uwzględnieniem krajowych wymagań.
In Poland there is lack of organized station for testing the flow characteristics of humidity controlled air transfer devices according to prEN 13141-9. Therefore, the method of testing in isothermal conditions, using facilities being on equipment of ITB Thermal Insulation Laboratory is presented in paper. This method is different than the method described in prEN 13141-9. At first, the degree of devices opening is determined in dependence on relative air humidity, then the air flow for assigned degrees of opening and for established difference of pressure is measured. Test resuts of humidity controlled air transfer devices are presented in paper, as well as their assessment with regard to the national requirements.
Źródło:
Prace Instytutu Techniki Budowlanej; 2008, R. 37, nr 4, 4; 3-15
0138-0796
Pojawia się w:
Prace Instytutu Techniki Budowlanej
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies