Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "regulator" wg kryterium: Temat


Tytuł:
An efficient microgrid model based on Markov fuzzy demand-side management
Autorzy:
Jabash Samuel, G. K.
Sivagama Sundari, M. S.
Bhavani, R.
Jasmine Gnanamalar, A.
Powiązania:
https://bibliotekanauki.pl/articles/27311444.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
smart grid
fuzzy Markov decision process
power scheduling
operating cost
nonlinear model predictive control
inteligentna sieć
planowanie mocy
koszt operacyjny
proces decyzyjny Markowa rozmyty
regulator predykcyjny nieliniowego modelu
Opis:
Today’s electricity management mainly focuses on smart grid implementation for better power utilization. Supply-demand balancing, and high operating costs are still considered the most challenging factors in the smart grid. To overcome this drawback, a Markov fuzzy real-time demand-side manager (MARKOV FRDSM) is proposed to reduce the operating cost of the smart grid system and maintain a supply-demand balance in an uncertain environment. In addition, a non-linear model predictive controller (NMPC) is designed to give a global solution to the non-linear optimization problem with real-time requirements based on the uncertainties over the forecasted load demands and current load status. The proposed MARKOV FRDSM provides a faster scale power allocation concerning fuzzy optimization and deals with uncertainties and imprecision. The implemented results show the proposed MARKOV FRDSM model reduces the cost of operation of the microgrid by 1.95%, 1.16%, and 1.09% than the existing method such as differential evolution and real coded genetic algorithm and maintains the supply-demand balance in the microgrid.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2023, 71, 3; art. no. e145569
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sterowanie przepływem towarów w magazynie z wykorzystaniem predyktora Smitha
Inventory goods flow control system using Smith predictor
Autorzy:
Chołodowicz, E.
Orłowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/276163.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
układ niestacjonarny
matematyczny model magazynu
systemy dyskretne
układ sterowania
predyktor Smitha
regulator PID
inventory control
inventory system
variable delay
discrete-time systems
Smith predictor
control systems
PID controller
Opis:
W pracy przedstawiono wyniki analizy literaturowej zagadnień związanych ze sterowaniem przepływem materiałów w systemach magazynowych. Na podstawie zaproponowanego dyskretnego, niestacjonarnego, dynamicznego modelu systemu magazynowego ze zmiennym w czasie opóźnieniem stworzono układ sterowania. Przedstawiona koncepcja usprawnienia przepływu towarów wykorzystuje predyktor Smitha z regulatorem PID. Do doboru optymalnych nastaw parametrów układu regulacji zastosowany został algorytm genetyczny. Wskaźnik jakości skonstruowano na bazie: kosztów tworzenia i utrzymania zapasów oraz utraconych zysków, tj. różnic między zapotrzebowaniem a sprzedażą produktów. Wskaźnik ten odzwierciedla, jak system sterowania zamówieniami nadąża za zmieniającymi się potrzebami rynku. Problem ten jest istotny w przedsiębiorstwach produkcyjnych i handlowych, które dążą do minimalizacji czasu realizacji operacji magazynowych i maksymalizacji przepustowości magazynu przy zapewnieniu ciągłości procesu produkcyjnego i sprzedaży. Sformułowano opis matematyczny systemu sterowania oraz problemu optymalizacji. Dokonano jego implementacji stosując algorytm genetyczny. Przedstawione zostały wyniki badań symulacyjnych ukazujące jakość zaproponowanego układu regulacji w środowisku MATLAB/Simulink.
There are a number of theorems and techniques that view inventory management from variant perspectives. The recent progress in research has resulted in innovative and more general techniques that can reduce the supply chain costs fundamentally. Modern inventory control is anchored in vastly advanced and complex models, which require considerable computational efforts. In this paper, we use a mathematical model of a warehouse system with time-varying delivery delay and adapt control system in order to apply it to the problem of goods flow in inventory systems. On the basis of the analysis of the inventory system, we propose a control system, then made its initial verification in the way of computer simulation in MATLAB/Simulink. The concept of improving the flow of materials is based on the structure of the Smith predictor and the PID controller. We perform optimization studies using genetic algorithm. Two quality indicators are subjected to minimization: the total costs of creating and maintaining inventories and differences between the demand and sales of products – the value of providing on whether the storage system keep up with the changing needs of the market (avoid stoppages). In this article, we mainly want to show that our idea of control system is able to achieve a high service level with maintaining a given inventory capacity to avoid redundancy.
Źródło:
Pomiary Automatyka Robotyka; 2015, 19, 3; 55-60
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of GA3 and the standard preservative on keeping qualities of cut LA hybrid lily ‘Richmond
Wpływ GA3 i pożywki standardowej na pozbiorczą trwałość ciętych kwiatów lilii mieszańca LA ‘Richmond’
Autorzy:
Rabiza-Świder, J.
Skutnik, E.
Jędrzejuk, A.
Łukaszewska, A.
Lewandowska, K.
Powiązania:
https://bibliotekanauki.pl/articles/11543000.pdf
Data publikacji:
2015
Wydawca:
Uniwersytet Przyrodniczy w Lublinie. Wydawnictwo Uniwersytetu Przyrodniczego w Lublinie
Tematy:
gibberellic acid zob.tez gibberellin A3
gibberellin A3
GA3 zob.gibberellin A3
growth regulator
flower longevity
cut
hybrid
lily
Richmond cultivar
postharvest treatment
sucrose
Opis:
The aim of the experiment was to evaluate effects of gibberellic acid and the standard preservative (composed of 8HQC and sucrose) on keeping qualities of cut lily flowering shoots (L. longiflorum × Asiatic hybrid, ‘Richmond’). These effects were tested in several experimental variants: the complete leafy shoot with the inflorescence (flowering shoot), inflorescence on a leafless shoot, decapitated leafy shoot, detached inflorescence and single leaves, in order to see how the components of a holding solution affect the particular plant organs on a lily flowering shoot. An experimental variant affected flower bud opening but less so the flower longevity. Keeping qualities such as vase life of lily flower and inflorescence, rate of bud opening and flower diameter were improved by the preservative only on a complete flowering shoot. Gibberellic acid as well the mixture of GA3 plus the standard preservative prolonged longevity of flowers in all the experimental variants. Gibberellic acid delayed leaf yellowing which was in turn hastened by the preservative except in leaves on decapitated shoots. Leaf senescence was the earliest in detached single leaves.
Celem badań było określenie wpływu kwasu giberelinowego i pożywki standardowej (zawierającej 8HQC i cukier) na trwałość ciętych kwiatów mieszańca LA lilii ‘Richmond’ (mieszaniec L. longiflorum z lilią azjatycką). Wykorzystano kilka warian tów: kompletny ulistniony pęd kwiatostanowy, kwiatostan na pędzie pozbawionym liści, ulistniony pęd pozbawiony kwiatostanu, odcięty kwiatostan i pojedyncze liście, by sprawdzić, jak składniki pożywki wpływają na poszczególne elementy pędu kwiatostanowego lilii. Wykazano, iż doświadczalny wariant ciętej lilii wpłynął na trwałość kwiatów w kwiatostanie i w mniejszym stopniu na ich rozwój. Pożywka standardowa przedłużyła trwałość kwiatów tylko w przypadku kompletnego pędu kwiatostanowego. Zastosowanie GA3 – samego bądź w połączeniu z pożywką standardową – przedłużyło trwałość kwiatów, bez względu na rodzaj modelu kwiatu. GA3 opóźnił również starzenie liści, które było wyraźnie szybsze po zastosowaniu roztworu 8HQC z 2% sacharozą, z wyjątkiem kombinacji, gdzie usunięto kwiatostan. Szybkość starzenia się liści uzależniona była od zastosowanego wariantu – najszybciej dekoracyjność traciły odcięte, pojedyncze liście.
Źródło:
Acta Scientiarum Polonorum. Hortorum Cultus; 2015, 14, 4; 51-64
1644-0692
Pojawia się w:
Acta Scientiarum Polonorum. Hortorum Cultus
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Propagation of endemic and endangered Sternbergia lutea with a high ornamental value by bulb chipping and plant growth regulators
Autorzy:
Nazari, F.
Powiązania:
https://bibliotekanauki.pl/articles/12301785.pdf
Data publikacji:
2019
Wydawca:
Uniwersytet Przyrodniczy w Lublinie. Wydawnictwo Uniwersytetu Przyrodniczego w Lublinie
Tematy:
Iran
wild plant
winter daffodil
Sternbergia lutea
endemic plant
endangered plant
rare plant
ornamental plant
bulbous plant
plant growth regulator
plant propagation
bulb chipping
bulb
bulblet
plant regeneration
Opis:
Autumn daffodil (Sternbergia lutea) is a rare and endangered bulbous plant with yellow flowers grown naturally in Iran and unfortunately for different reasons this plant is at the risk of eradication. Natural multiplication rate of S. lutea is low, thus propagation by chipping method is one inexpensive and simple way to overcome this problem. This research was therefore performed to investigate the propagation method in two experiments. In the first experiment, the effects of some plant growth regulators (PGRs) on induction and regeneration of bulblets from bulb chips (propagules) were evaluated. The propagules were prepared by chipping method and treated with indole butyric acid (IBA), gibberellic acid (GA3), benzyl adenine (BA), kinetin (Kin) and cycocel (CCC) at 100 and 200 mg L–1 concentrations for 2 h and then incubated for two months at 20 ±1°C. At the end of incubation, the results showed the highest percentage of concurrent bulblet + root regeneration (CBRR), number and fresh weight of bulblets related to 100 mg L–1 GA3. The highest percentage of only bulblet regeneration (OBR), only root regeneration (ORR) and non-regeneration were obtained at 200 mg L–1 IBA, 100 mg L–1 Kin and control (distillated water: DW) treatments, respectively. In the second experiment, the bulblets that had rooted from each treatment of the first experiment were planted and the produced bulbs were compared. The results indicated that the highest percentage of bulblet sprouting, bulb number and diameter were found at 100 mg L–1 GA3. Therefore, the application of GA3 with mentioned concentration is appropriate for vegetative propagation of this plant by bulb chipping.
Źródło:
Acta Scientiarum Polonorum. Hortorum Cultus; 2019, 18, 2; 123-131
1644-0692
Pojawia się w:
Acta Scientiarum Polonorum. Hortorum Cultus
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of growth regulators on dahlia propagation in tissue culture and acclimatization of plants in ex vitro conditions
Autorzy:
Marcinek, B.
Parzymies, M.
Poniewozik, M.
Kozak, D.
Durlak, W.
Powiązania:
https://bibliotekanauki.pl/articles/12307379.pdf
Data publikacji:
2019
Wydawca:
Uniwersytet Przyrodniczy w Lublinie. Wydawnictwo Uniwersytetu Przyrodniczego w Lublinie
Tematy:
plant cultivation
Dahlia
Dahlia x cultorum
dahlia
ornamental plant
flowering plant
tuberous plant
tuberous root
plant acclimatization
growth regulator
cytokinin
gibberellic acid
micropropagation
tissue culture
ex vitro method
microcutting
Opis:
The aim of the work was to evaluate the influence of cytokinins on in vitro propagated dahlia and their consequent effect on acclimatization. Plant material consisted of shoot tips and nodes. Among the three cytokinins, benzyladenine, kinetin and 2-isopentenyl-adenine, only BA effectively stimulated the shoot multiplication from axiliary buds. The highest multiplication rate was obtained from nodes in the presence of 0.25– 0.5 mg·dm–3 BA. Higher concentrations shortened the internodes and decreased the leaf blades and growth of callus. 1 mg·dm–3 of KIN and 2iP positively influenced the shoot growth and size of leaves. Gibberellic acid (GA3) used with BA increased the number of auxillary shoots. The best quality shoots and the highest multiplication rate were obtained when 2 mg·dm–3 BA was used with 5 mg·dm–3 GA3. Cytokinins affected the rooting and acclimatization ex vitro. Dahlia shoots multiplicated in the presence of 1 mg·dm–3 KIN or 2iP rooted faster in the soil and 100% survived in field, while those from 1 mg·dm–3 BA media rooted slowly, had shorter shoots and only 60% of them survived. Plants bloomed after 11–12 weeks in the field. Dahlia plants that had been multiplicated in the presence of KIN had larger diameter and fresh weight in the field. BA and 2iP positively influenced the flower diameter, length of flower stalk and a number of the first-order shoots.
Źródło:
Acta Scientiarum Polonorum. Hortorum Cultus; 2019, 18, 5; 49-61
1644-0692
Pojawia się w:
Acta Scientiarum Polonorum. Hortorum Cultus
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of melatonin, GA3 and NAA on vegetative growth, yield and quality of ‘Canino’ apricot fruits
Autorzy:
Abd El-Naby, S.K.M.
Abdelkhalek Ahmed Mohamed, M.
El-Naggar, Y.I.M.
Powiązania:
https://bibliotekanauki.pl/articles/12684291.pdf
Data publikacji:
2019
Wydawca:
Uniwersytet Przyrodniczy w Lublinie. Wydawnictwo Uniwersytetu Przyrodniczego w Lublinie
Tematy:
plant cultivar
apricot
Canino cultivar
fruit tree
fruit quality
fruit yield
vegetative growth
field experiment
gibberellic acid
melatonin
plant growth regulator
naphthaleneacetic acid
titratable acidity
total soluble solid
Opis:
A field experiment was carried out during 2017–2018 in the Horticulture Research Station farm in El Kanater El Khayreia, El Kalubeia Governorate, Egypt, to find out the response of foliar application of melatonin, GA3 and NAA on vegetative and fruit attributes of ‘Canino’ apricot. Different plant growth regulators influenced all variable parameters related to vegetative growth and fruit. Results revealed that between all growth regulators, the foliar application of melatonin following by GA3 there was the highest vegetative growth as compared to other treatments, while GA3 gave the highest yield following by melatonin as compared to other treatments. Treatment with NAA improved vegetative growth, yield and fruit quality to a lesser extent as compared to the control.
Źródło:
Acta Scientiarum Polonorum. Hortorum Cultus; 2019, 18, 3; 167-178
1644-0692
Pojawia się w:
Acta Scientiarum Polonorum. Hortorum Cultus
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A fuzzy logic approach to shunt active power filter and hybrid active power filter
Autorzy:
Sahoo, Nirjharini
Panda, Gayadhar
Subudhi, B. D.
Powiązania:
https://bibliotekanauki.pl/articles/41189662.pdf
Data publikacji:
2023
Wydawca:
Politechnika Warszawska, Instytut Techniki Cieplnej
Tematy:
Index terms
shunt active power filter
hybrid active power filter
hysteresis current controller
total harmonic distortion (THD)
indirect current controller
filtr mocy czynnej
filtr hybrydowy
zniekształcenie harmoniczne
regulator prądu
Opis:
This paper describes a Fuzzy Logic approach to Shunt Active power filter (SAPF) versus Hybrid Active Power Filter (HAPF) using Simulink. Here hysteresis controlled PWM method is applied to the SAPF and HAPF as a current controller and Fuzzy logic controller as a inverter dc voltage controller. To reduce harmonics, Shunt Active Power Filters (SAPFs) are used with various control schemes, but Hybrid Active power filter is a power electronic device which has both the characteristics of passive power filters and active power filters, which helps in cancelation of the harmonics by producing compensating signal. The fuzzy-hysteresis controller is designed and its simulation results are presented for both the filter types, showing acceptable THD results for the word length used in the fixed-point computations involved in the switching sequence generation. The results of the above controller are compared with the Indirect current controller.
Źródło:
Journal of Power Technologies; 2023, 103, 4; 209-217
1425-1353
Pojawia się w:
Journal of Power Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metoda doboru nastaw regulatora PID dla liniowych obiektów z opóźnieniem rzeczywistym i o monotonicznie rosnącej charakterystyce skokowej
The method of seting of PID - controller for linear plants with real delay and monotonically growing step response
Autorzy:
Żuchowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/152053.pdf
Data publikacji:
2005
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
metoda doboru nastaw regulatora PID
obiekty liniowe
opóźnienie rzeczywiste
monotonicznie rosnąca charakterystyka skokowa
regulator PID
methods of setting of PID
PID controller
linear plants with real delay
monotonically growing step response
Opis:
Wśród wielu metod doboru nastaw regulatora PID na wyróżnienie zasługuje metoda S. Skoczowskiego dostosowana do obiektów z opóźnieniem rzeczywistym i inercją drugiego rzędu. Zaproponowano rozszerzenie tej metody dla obiektów o bardziej złożonych modelach dynamiki.
The Skoczowski`s method of setting of PID - controller deserves to be the favorable one. The method is adjusted to plants represented by second order interia models with real delays. The pfroposal of adopting of this method to more complicated models of plant dynamic is presented.
Źródło:
Pomiary Automatyka Kontrola; 2005, R. 51, nr 7-8, 7-8; 9-11
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biorational control of arthropod pests with emphasis on the use of the chitin synthesis inhibitor novaluron
Autorzy:
Ishaaya, I.
Lebedev, G.
Ghanim, M.
Horowitz, A.R.
Powiązania:
https://bibliotekanauki.pl/articles/55215.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Przemysłu Organicznego
Tematy:
biorational control
arthropod
pest
chitin synthesis
novaluron
insecticide
insect
growth regulator
buprofezin
diflubenzuron
chlorfluazuron
pyriproxyfen
tebufenozide
methoxyphenozide
neonicotinoid
imidacloprid
acetamiprid
thiamethoxam
glutamate receptor
gamma-aminobutyric acid
abamectin
Spinosad preparation
novel insecticide
Opis:
Efforts have been made during the past three decades to develop insecticides with selective properties that act specifically on biochemical sites present in a particular insect group, but whose properties differ from those present in mammals. This approach has led to the discovery of compounds that affect the hormonal regulation of molting and developmental processes in insects such as ecdysone agonists, juvenile hormone (JH) mimics and chitin synthesis inhibitors. The search for potent acylureas has led to the development of novaluron (Rimon) developed by Makhteshim Chemical Works. The LC-50 value of novaluron on 3rd-instar Spodoptera littoralis fed on treated leaves is approximately 0.1 mg a.i./liter. This value resembles that of chlorfluazuron and is tenfold lower than that of teflubenzuron. Novaluron affects nymphs of Bemisia tabaci more than chlorfluazuron and teflubenzuron. Artificial rain, at a rate of 40 mm/h applied 5 and 24 h after treatment in a cotton field had no appreciable effect on the potency of novaluron on both S. littoralis larvae and B. tabaci nymphs. Hence, novaluron can be used in tropical areas and during rainy seasons. In general, benzoylphenyl ureas had no direct effect on parasitoids and phytoseiids and are considered mildly affect other natural enemies. Novaluron has no cross-resistance with conventional insecticides, the JH mimics pyriproxyfen and neonicotinoids. As such, it is considered an important compound in pest management programs.
Źródło:
Pestycydy; 2011, 1-4
0208-8703
Pojawia się w:
Pestycydy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improved cut flower and corm production by exogenous moringa leaf extract application on gladiolus cultivars
Autorzy:
Younis, A.
Akhtar, M.S.
Riaz, A.
Zulfiqar, F.
Qasim, M.
Farooq, A.
Tariq, U.
Ahsan, M.
Bhatti, Z.M.
Powiązania:
https://bibliotekanauki.pl/articles/11855333.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet Przyrodniczy w Lublinie. Wydawnictwo Uniwersytetu Przyrodniczego w Lublinie
Tematy:
Pakistan
Faisalabad city
ornamental plant
Gladiolus
Gladiolus grandiflorus
Rose Supreme cultivar
White Prosperity cultivar
cut flower
corm
corm size
spike length
vase life
growth regulator
Moringa oleifera
leaf extract
climate condition
Opis:
Bio-stimulants are in excessive demand for the sustainable production of floriculture crops. The current investigation was designed to find out the effect of naturally occurring growth stimulant moringa leaf extract (MLE) on the growth, flowering, post-harvest life and corm production of two gladiolus cultivars (cvs.) ‘Rose Supreme’ and ‘White Prosperity’. The research trial was laid out in the factorial arrangement under randomized complete block design. Corms were grown in the open field under local climatic conditions of Faisalabad, Pakistan. Potential of exogenously applied (MLE; 30 times diluted) was evaluated. Treatments including spraying MLE at 3 leaves, 5 leaves, floral bud stage, one combination of these three stages relative to control with no foliar application. Application of natural bio-stimulant produced maximum height in both cvs. against T4. Both cvs. gave maximum stalk length in response to T4. The number of florets spike–1 found the maximum (13) in T1 compared to control T0 which yield (9) florets. Maximum vase life in sucrose solution (13.33 days) was exhibited by T1 for both cvs. while minimum (10 days) in T0. In cultivar comparison earlier spike emergence was observed in ‘White Prosperity’. In ‘Rose Supreme’ maximum corm weight was attained in response to T3 (43.43 g) while minimum (30.33 g) in T0.‘White Prosperity’ produced maximum weight (40.33 g) against T4 whereas minimum by control. The cultivar mean comparison showed the superiority of cormel diameter in ‘Rose Supreme’ (10.93 mm) than ‘White Prosperity’ (9.13 mm). In treatment comparison, T4 produced maximum diameter (12.04 mm) in ‘Rose Supreme’ moreover, T2 induced maximum (9.57 mm) diameter in ‘White Prosperity’.
Źródło:
Acta Scientiarum Polonorum. Hortorum Cultus; 2018, 17, 4; 25-38
1644-0692
Pojawia się w:
Acta Scientiarum Polonorum. Hortorum Cultus
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ mikroinstalacji fotowoltaicznych na wybrane parametry jakości energii elektrycznej oraz pracę agregatów w sieci dystrybucyjnej niskiego napięcia
The impact of photovoltaic micro-installations on selected power quality parameters and the operation of the mobile power generation units in a low-voltage distribution network
Autorzy:
Topolski, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/2069859.pdf
Data publikacji:
2021
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
mikroinstalacje fotowoltaiczne
wzrosty i asymetria napięć
agregat prądotwórczy
transformator symetryzujący
szeregowy transformator dodawczy
photovoltaic micro-installations
voltage swells and unbalance
mobile power generation unit
balancing transformer
series automatic voltage regulator
Opis:
Duża koncentracja jednofazowych mikroinstalacji fotowoltaicznych w nisko obciążonej sieci dystrybucyjnej niskiego napięcia często ma negatywny wpływ na parametry jakości energii elektrycznej, co skutkuje automatycznym wyłączaniem się falowników oraz utrudnia służbom energetycznym prowadzenie prac eksploatacyjnych z wykorzystaniem agregatów prądotwórczych. W artykule wyjaśniono i przedstawiono wpływ jednofazowych mikroinstalacji fotowoltaicznych o mocy 2 kW na wartość skuteczną napięcia i asymetrię prądową i napięciową oraz omówiono współpracę agregatu prądotwórczego z mikroinstalacjami. W artykule zaprezentowano również wyniki pomiarów skuteczności łagodzenia negatywnego wpływu mikroinstalacji na parametry napięcia za pomocą transformatora symetryzującego oraz szeregowego transformatora dodawczego, z niezależną regulacją napięcia w poszczególnych fazach.
High concentration of single-phase photovoltaic micro-installations on a low-loaded low-voltage distribution feeder often has a negative impact on power quality parameters which leads to automatic photovoltaic inverters shutdown and obstructs distribution network maintenance using mobile power generation units. The paper presents the impact of 2 kW single-phase micro-installations on voltage profile and voltage and current unbalance in a low-voltage distribution network. The paper also discusses cooperation of a mobile power generation unit with micro-installations and presents the results of measurements of mitigation effectiveness of the negative impact of micro-installations on voltage quality using a balancing transformer and a series automatic voltage regulator with independent phase voltage regulation.
Źródło:
Energetyka Rozproszona; 2021, 4; 41--62
2720-0973
Pojawia się w:
Energetyka Rozproszona
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie TKEO w procesie automatycznego wyważania wirnika
Application of TKEO in the process of automatic balancing of the rotor
Autorzy:
Blaut, Jędrzej
Rumin, Rafał
Cieślik, Jacek
Hyla, Paweł
Szpytko, Janusz
Powiązania:
https://bibliotekanauki.pl/articles/314574.pdf
Data publikacji:
2019
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
TKEO
Teager-Kaiser
operator energetyczny Teagera-Kaisera
aktywna kontrola drgań
maszyny wirnikowe
wyważanie wirników
regulator
dynamika wirnika
Teager-Kaiser energy operator
active vibration control
rotating machinery
rotor balancing
controller
rotor dynamics
Opis:
W artykule zaprezentowano przykład zastosowania Operatora Energetycznego Teagera-Kaisera w automatycznym wyważaniu wirnika. Operator Energetyczny Teagera-Kaisera jest metodą analizy sygnału, która pozwala w dla niektórych obiektów mechanicznych oszacować zmiany energii w ujęciu newtonowski za pomocą sygnału przemieszczenia. Wirniki są elementem konstrukcyjnym wykonującym obrót wokół osi. Tradycyjne wyważanie wirników polega na wprowadzaniu mas korekcyjnych, których celem jest zmniejszenie drgań i hałasu podczas pracy maszyn. Możliwe jest również nadążne wyważania rotorów. Może ono być realizowane przez system mas korekcyjnych o zmiennej odległości od osi obrotu. Zmiana odległości masy korekcyjnej od osi obrotu wpływa na zmianę bezwładności obiektu a tym samym zmniejsza niewyważenie. W zależności od konstrukcji urządzenia modernizacja może zakładać rozbudowę lub wymianę poszczególnych elementów. Poprawa pracy urządzenia wymaga selekcji elementów w zależności od całościowej ingerencji w pracę maszyny oraz wpływu na prace całego urządzenia. Przedstawiona autorska metoda sterowania automatycznego niewyważeniem z wykorzystaniem Operatora Energetycznego z doborem parametrów została wykonana na rzeczywistym stanowisku laboratoryjnym.
The article presents an example of application of the Teager-Kaiser Energy Operator in automatic rotor balancing. The Teager-Kaiser Energy Operator is a signal analysis method, which allows for some mechanical objects to estimate energy changes in Newtonian terms by means of a displacement signal. Rotors are a structural element that rotates around an axis. Traditional balancing of the rotors is based on the introduction of correction masses, the aim of which is to reduce vibrations and noise during machine operation. Traditional balancing of the rotors is also possible. It can be realized by a system of correction masses with variable distance from the axis of rotation. The change of the correction mass distance from the axis of rotation influences the change of inertia of the object and thus reduces the unbalance. Depending on the design of the device, the modernization may assume extension or replacement of individual elements. Improvement of the operation of the device requires selection of elements depending on the overall interference in the operation of the machine and the impact on the operation of the entire device. The presented original method of automatic unbalance control with the use of the Energy Operator with the selection of parameters has been performed on a real laboratory stand.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2019, 20, 1-2; 161-166
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reparation of voltage disturbance using PR controller-based DVR in Modern power systems
Autorzy:
Danalakshmi, D.
Prathiba, Srividya
Ettappan, M.
Krishna, Mohan D.
Powiązania:
https://bibliotekanauki.pl/articles/1839555.pdf
Data publikacji:
2021
Wydawca:
Stowarzyszenie Menedżerów Jakości i Produkcji
Tematy:
smart grid
jakość energii elektrycznej
regulator PI i PR
ewolucja
DVR
współczynnik zawartości harmonicznych
power quality
PI and PR controller
self balanced differential
evolution
dynamic voltage restorer
total harmonic distortion
Opis:
The Smart Grid environment gives more benefits for the consumers, whereas the power quality is one of the challenging factors in the smart grid environment. To protect the system equipment and increase the reliability, different filter technologies are used. Even though, consumers’ expectations towards the power quality are not fulfilled. To overcome these drawbacks and enhance the system reliability, a new Custom Power Devices (CPD) are introduced in the system. Among different CPDs, the Dynamic Voltage Restorer (DVR) is one of the voltage compensating devices that is used to improve the power quality during distortions. When the distortions such as voltage swell and sag occur in the distribution system, the control strategy in the DVR plays a significant role. In this article, the DVR performance using Proportional Integral (PI), Proportional Resonant (PR) controllers are analyzed. A robust optimization algorithm called Self Balanced Differential Evolution (SBDE) is used to find the optimal gain values of the controllers in order to reach the target of global minimum error and obtain fast response. Then, a comparative analysis is performed between different controllers and verified that the performance of PR controller is superior than the other controllers. It has been found that the proposed PR controller strategy reduces the Total Harmonic Distortion (THD) values for all types of faults. The proposed SBDE optimized DVR with PR controller reduces the THD value less than 4% under voltage distoration condition. The DVR topology is validated in MATLAB/SIMULINK in order to detect the disturbance and inject the voltage to compensate the load voltage.
Źródło:
Production Engineering Archives; 2021, 27, 1; 16-29
2353-5156
2353-7779
Pojawia się w:
Production Engineering Archives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Regulatory roslinne - ich rola i wykorzystanie w uprawie ziemniaka
Autorzy:
Erlichowski, T
Powiązania:
https://bibliotekanauki.pl/articles/834942.pdf
Data publikacji:
1999
Wydawca:
Instytut Hodowli i Aklimatyzacji Roślin
Tematy:
cytokininy
auksyny
kwas abscysynowy
triakontanol
ziemniaki
retardanty
kwas jasmonowy
brasinosteroidy
gibereliny
inhibitory wzrostu
regulatory wzrostu
cytokinin
auxin
abscisic acid
triacontanol
potato
retardant
jasmonic acid
brassinosteroid
gibberellin
growth inhibitor
growth regulator
Źródło:
Ziemniak Polski; 1999, 2; 14-18
1425-4263
Pojawia się w:
Ziemniak Polski
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The implementation of a coefficient diagram method based polynomial controller for a non-linear process with a distributed control system in a chlorine scrubber system
Implementacja wielomianowego regulatora opartego na metodzie diagramu współczynników dla procesu nieliniowego z rozproszonym systemem sterowania w systemie płuczki chloru
Autorzy:
Murugan, T. Maris
Shankar, T.R. Kiruba
Powiązania:
https://bibliotekanauki.pl/articles/2173816.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
chlorination scrubber system
PID controller
distributed control system
DCS
coefficient diagram method
CDM
interacting conical tank
system oczyszczania chloru
regulator PID
rozproszony system sterowania
metoda diagramu współczynników
współpracujący zbiornik stożkowy
Opis:
The seawater desalination process is emerging as a substantial source of fresh water by removing salt and minerals from an infinite supply of seawater effectively. The first stage in a desalination plant is the use of chlorine gas to sterilize the microorganisms in the water. During excess chlorine leakage, an alert is activated, employees are relocated away from the site for a specific period, and dampers will be manually opened. This will cause unsafe working conditions and a waste of time. To overcome this problem, this paper proposes a coefficient diagram method based proportional integral derivative (CDM-PID) control strategy for the tune the control parameter with the distributed control system (DCS) interfaced conical tank. During operation, a 10% NaOH solution is injected into the top of the scrubber column using an ethylene-ter-polymer (ETA) designed distributor to ensure that the solution is evenly distributed across the packing surface. The three control strategies are compared to tune the control parameter with the DCS interfaced conical tank. Instead of the sodium hydroxide tank in the chlorine scrubber system, this work presents the pilot plant of DCS interfaced with two conical tank interacting systems with different liquid level heights. Here, the proposed CDM-PID controller is compared with the standard Ziegler-Nichols (ZN)-ultimate cycling method, and the internal model control (IMC) method. The results demonstrated that the proposed CDM-PID approach is superior to existing approaches in terms of low oscillation, settling period, and high robustness.
Proces odsalania wody morskiej staje się znaczącym źródłem świeżej wody dzięki skutecznemu usuwaniu soli i minerałów z nieskończonych zasobów wody morskiej. Pierwszym etapem w zakładzie odsalania jest użycie chloru gazowego do sterylizacji mikroorganizmów w wodzie. Podczas nadmiernego wycieku chloru zostanie aktywowany alarm, pracownicy zostaną na pewien czas przeniesieni z terenu zakładu, a klapy zostaną ręcznie otwarte. Spowoduje to niebezpieczne warunki pracy i stratę czasu. Aby rozwiązać ten problem, w niniejszym artykule zaproponowano strategię sterowania opartą na metodzie wykresu współczynników proporcjonalno-całkująco-różniczkujących (Coefficient Diagram Method-Proportional Integral Derivative – CDM-PID) w celu dostrojenia parametru sterowania za pomocą zbiornika stożkowego połączonego z rozproszonym systemem sterowania (Distributed Control System – DCS). Podczas pracy do góry płuczki wstrzykuje się 10% roztwór NaOH za pomocą dystrybutora zaprojektowanego z etylenu-ter-polimeru (Ethylene-Ter-Polymer – ETA), aby zapewnić równomierne rozprowadzenie roztworu na powierzchni wypełnienia. Trzy strategie sterowania są porównywane w celu dostrojenia parametru kontrolnego za pomocą zbiornika stożkowego połączonego z DCS. Zamiast zbiornika wodorotlenku sodu w systemie płuczki chloru, w niniejszej pracy przedstawiono Instalację Pilotażową DCS połączoną z dwoma współpracującymi ze sobą stożkowymi układami zbiorników o różnych wysokościach poziomu cieczy. Tutaj, proponowany regulator CDM-PID jest porównywany ze standardową metodą Zieglera-Nicholsa (ZN)-Ultimate Cycling oraz metodą kontroli modelu wewnętrznego (Internal Model Control – IMC). Wyniki pokazały, że proponowane podejście CDM-PID przewyższa istniejące podejścia pod względem niskich oscylacji, okresu osiadania i wysokiej odporności.
Źródło:
Gospodarka Surowcami Mineralnymi; 2022, 38, 4; 231--255
0860-0953
Pojawia się w:
Gospodarka Surowcami Mineralnymi
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies