Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "zwarcia zwojowe" wg kryterium: Temat


Wyświetlanie 1-9 z 9
Tytuł:
Model polowo–obwodowy silnika indukcyjnego ze zwarciami zwojowymi
Field-circuit mathematical model of the induction motor with shorted turns in the stator winding
Autorzy:
Ewert, P.
Kowalski, C. T.
Wolkiewicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/1813810.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
silnik indukcyjny
model polowo-obwodowy
zwarcia zwojowe
Opis:
In the paper a filed-circuit mathematical model of the induction motor is presented, which enables a simulation of short-circuits turns in the stator winding. The classical field-circuit model has been analyzed first, and next its modification was proposed. The extension of basic model was realized in Ansoft Maxwell Circuit Editor software. The developed model enables simulation of 12 short-circuit turns in each stator winding phase. Hodographs of the stator current vector in α–β plane as well as results of spectral analysis of the stator phase current and modulus of stator current vector are presented in the paper. The simulation results are verified by experimental tests.
Źródło:
Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych Politechniki Wrocławskiej. Studia i Materiały; 2013, 69, 33; 194--206
1733-0718
Pojawia się w:
Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych Politechniki Wrocławskiej. Studia i Materiały
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania skutków cieplnych zwarć zwojowych w uzwojeniach stojana silnika indukcyjnego
Effects of inter-turns short-circuits in stator winding of squirrel-cage induction motor
Autorzy:
Antal, L.
Gwoździewicz, M.
Marciniak, T.
Antal, M.
Powiązania:
https://bibliotekanauki.pl/articles/1812151.pdf
Data publikacji:
2012
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
silnik indukcyjny
zwarcia zwojowe uzwojenia stojana
badania cieplne
Opis:
Phenomena associated with inter-turn short-circuit in stator winding of low power squirrel-cage motor were investigated. Investigations were realized with physical model of the motor with adapted stator winding coil with terminals to make inter-turns short-circuit. During laboratory tests 4, 12, 22 and 51 turns of the 306 phase stator winding were short-circuited. Thermal phenomena during 30 seconds shortcircuits were investigated. After short-circuits thermograms of the stator winding were recorded.
Źródło:
Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych Politechniki Wrocławskiej. Studia i Materiały; 2012, 66, 32; 316-324
1733-0718
Pojawia się w:
Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych Politechniki Wrocławskiej. Studia i Materiały
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie strumienia unipolarnego w diagnostyce maszyn prądu przemiennego
Applicaton of Unipolar Fluxi in Diagnosing ac Machines
Autorzy:
Petryna, J.
Sułowicz, M.
Duda, A.
Guziec, K.
Powiązania:
https://bibliotekanauki.pl/articles/1368421.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
strumień unipolarny
zwarcia zwojowe
uszkodzenie klatki
unipolar flux
short circuits
cage damage
Opis:
The article contains the results of research within the project to use unipolar (axial) flux coil to obtain diagnostic signal carrying the information of: electrical asymmetries of machinery (inter-turn stator short-circuits, cage damages); rotational speed of the rotor. Inter-turn stator short-circuits can be detected both at starting process time (when they appear most often), as well as in steady states. Detection of rotor cage defects in steady states has a character of a comparative study, and over time, as the defects develop. For standard drives that are powered from the network and work in open systems, by measuring the voltage following a unipolar flux, it is possible as necessary to make measurement and recording of motor speed, which usually is almost never provided under industrial conditions, also for the purpose of measurement of dynamic states and variability of rotation. The study shows that a simple in its construction, cheap coil can be a very useful diagnostic tool. Diagnosing machines using this method can be a valuable supplement, as well as confirmation of the results of studies carried out by other means.
Artykuł zawiera wyniki badań w ramach projektu wykorzystania cewki do pomiaru strumienia unipolarnego dla uzyskania sygnału diagnostycznego niosącego informacje: o niesymetriach elektrycznych maszyny (zwarcia zwojowe, defekty klatki); o prędkości obrotowej wirnika. Zwarcia zwojowe mogą być wykrywane zarówno w czasie rozruchu (kiedy to ujawniają się najczęściej), jak i w stanie ustalonym. Wykrywanie defektów klatki w stanie ustalonym ma charakter badania porównawczego oraz w miarę rozwoju defektu klatki. Dla napędów standardowych, które są zasilane z sieci i pracują w układach otwartych można poprzez pomiar napięcia odwzorowującego strumień unipolarny dokonywać w razie potrzeby pomiaru i rejestracji prędkości obrotowej, co przeważnie prawie nigdy nie jest zapewniane w warunkach przemysłowych, również dla potrzeb pomiaru stanów dynamicznych i zmienności obrotów. W pracy pokazano, że prosta w swej konstrukcji, tania cewka może być bardzo przydatnym narzędziem diagnostycznym. Diagnozowanie maszyn tą metodą stanowić może cenne uzupełnienie, jak również potwierdzenie wyników badań zrealizowanych przy użyciu innych środków.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 2, 99; 85-90
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykrywanie i lokalizacja zwarć zwojowych silnika indukcyjnego przy wykorzystaniu analizy składowych głównych hodografu wektora przestrzennego prądu stojana
Detection and localization of induction motor stator windings fault using principal components analysis of stator current space vector hodograph
Autorzy:
Wolkiewicz, M.
Kowalski, C. T.
Powiązania:
https://bibliotekanauki.pl/articles/1807704.pdf
Data publikacji:
2011
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
silnik indukcyjny
monitorowanie
zwarcia zwojowe
model matematyczny silnika uszkodzonego
analiza składowych głównych
Opis:
In this paper analysis of stator vector currents hodograph changes for detection and localization shorted turns in induction motor is presented. Attention has been paid to distortion of stator vector currents hodograph caused by shorted-turns in one motor winding phase. Method based on principal components analysis is used for detection and condition evaluation of the stator windings. The mathematical model of induction motor in the case of stator fault is proposed. The fault level is modeled by changing number of shorted winding turns in one phase. Change of fault localizations is realized by modeling of turn to turn faults in each phase sequentially.
Źródło:
Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych Politechniki Wrocławskiej. Studia i Materiały; 2011, 65, 31; 179-191
1733-0718
Pojawia się w:
Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych Politechniki Wrocławskiej. Studia i Materiały
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka uszkodzeń uzwojeń stojana silnika indukcyjnego z wykorzystaniem dyskretnej transformaty falkowej obwiedni prądu stojana
Diagnosis of induction motor stator winding fault using discrete wavelet analysis of the stator current envelope
Autorzy:
Wolkiewicz, M.
Kowalski, C.
Powiązania:
https://bibliotekanauki.pl/articles/1367714.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
silnik indukcyjny
zwarcia zwojowe
obwiednia prądu stojana
dyskretna transformata falkowa
induction motor
inter-turn fault
envelope of stator current
discrete wavelet transforms
Opis:
This paper deals with the application of stator current envelope analysis in the incipient diagnosis of the stator winding short circuits. To separate of the characteristic symptoms of stator damage Discrete Wavelet Transform were used. Based on this analysis the energy coefficients of the stator current envelope for the chosen decomposition levels were calculated. The proposed method was implemented for a small power induction motor (with special physical modeling of shorted turns in the stator phases) supplied by voltage source inverter in open control loop. The virtual measurement-diagnostic device, developed in the LabVIEW environment includes algorithms: data acquisition, Hilbert transform for the determination of stator current envelope and wavelet transform to extract the failure symptoms. Experimental results presented In this paper show that changes of the proposed energy factor constitutes a very efficient index for the evaluation of the stator winding state.
W artykule przedstawiono analizę możliwości wykorzystania sygnału obwiedni prądu fazowego stojana do wykrywania zwarć zwojowych, w możliwie wczesnej fazie powstania uszkodzenia. Do wyodrębnienie charakterystycznych dla uszkodzenia stojana symptomów wykorzystano dyskretną transformatę falkową oraz obliczony na jej podstawie współczynnik zmian energii sygnału dla wybranych poziomów dekompozycji. Badania eksperymentalne zrealizowano dla silnika indukcyjnego małej mocy zasilanego z przemiennika częstotliwości w otwartej pętli sterowania (sterowanie skalarne U/f=const). Środowisko LabVIEW posłużyło do zaprojektowania oraz przetestowania aplikacji przyrządu pomiarowo-diagnostycznego. Aplikacja zawierała algorytmy: akwizycji danych, transformaty Hilberta do wyznaczenia obwiedni sygnału oraz transformaty falkowej sygnału do wyodrębnienia symptomów uszkodzenia. Zmiany wartości współczynnika zmian energii dla obwiedni prądu stojana dla poszczególnych poziomów dekompozycji okazały się bardzo dobrym kryterium oceny stanu uzwojenia stojana.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2015, 3, 107; 13-18
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie dyskretnej analizy falkowej do wykrywania zwarć zwojowych w silniku indukcyjnym
Application of Discrete Wavelet Analysis to Detect Interturn Faults in the Induction Motor
Autorzy:
Wolkiewicz, M.
Kowalski, C. T.
Powiązania:
https://bibliotekanauki.pl/articles/1368669.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
silnik indukcyjny
zwarcia zwojowe
wektor przestrzenny prądu stojana
dyskretna transformata falkowa
induction motor
inter-turn fault
stator current space vector
discrete wavelet transform
Opis:
This paper deals with the application of space current vector analysis combined with Wavelet Transform in the incipient diagnosis of the stator winding short circuits. The proposed method was implemented for a small power induction motor (with special physical modeling of shorted turns in the stator phases) supplied by ideal sinusoidal-voltage-source. The data acquisition and analysis was realized using virtual measurement-diagnostic device developed in the LabVIEW environment. Wavelet Transform was done up to the third decomposition level of the measured current signal to enable the observation of the fault symptoms In the frequency range (64÷128) Hz. Based on this analysis the energy coefficient of the signal |is|E for the chosen decomposition level was calculated. Changes of this factor constitutes a very efficient index for the evaluation of the stator winding state.
W artykule przedstawiono analizę możliwości wykorzystania sygnału wektora przestrzennego prądu stojana, uzupełnioną o dyskretną transformatę falkową do wykrywania zwarć zwojowych, w możliwie wczesnej fazie powstania uszkodzenia. Badania eksperymentalne zrealizowano dla silnika indukcyjnego małej mocy (specjalna konstrukcja umożliwiająca badanie zwarć zwojowych w każdej fazie silnika) zasilanego z programowalnego idealnego źródła napięcia. Akwizycja oraz analiza danych została przeprowadzona z wykorzystaniem wirtualnego przyrządu pomiarowo-diagnostycznego zaprojektowanego w środowisku LabVIEW. Analiza falkowa została przeprowadzona do trzeciego poziomu dekompozycji sygnału tak, aby uzyskać możliwość badania w zakresie częstotliwości od 64 do 128Hz, gdyż w tym przedziale częstotliwości znajduje się harmoniczna charakterystyczna dla zwarć zwojowych. Na podstawie wyników analizy falkowej został obliczony współczynnik zmian energii sygnału |is|E dla wybranego poziomu dekompozycji. Zmiany wartości współczynnika zmian energii dla detalu na trzecim stopniu dekompozycji okazały się bardzo dobrym kryterium oceny stanu uzwojenia stojana.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 4, 100/2; 191-196
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the features of application of vibration diagnostic methods of induction motors of transportation infrastructure using mathematical modeling
Autorzy:
Gubarevych, Oleg
Gerlici, Juraj
Gorobchenko, Oleksandr
Kravchenko, Kateryna
Zaika, Denys
Powiązania:
https://bibliotekanauki.pl/articles/2174469.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
vibration diagnostics
simulation modelling
induction motor
stator field asymmetry
turn-to-turn short circuits
diagnostyka drgań
modelowanie symulacyjne
silnik indukcyjny
uzwojenie stojana
zwarcia zwojowe
Opis:
In the work, studies were carried out on the use of vibration diagnostic methods for monitoring the state of induction motors with a squirrel-cage rotor, operated in electric drives of transport equipment. The most common and difficult-todiagnose damage to an induction motor is turn-to-turn short circuits in the stator winding, which require timely determination and establishment of the degree of damage to prevent an emergency shutdown of the equipment. The main purpose of the study is to establish the most effective areas of application of vibration diagnostic methods in determining the technical condition of the stator of induction motors under load. The experiments were carried out using simulation modeling for cases of turn-to-turn short circuits in one and two phases simultaneously, as well as with the influence of a low-quality supply voltage system on vibration parameters. The results of the work are relevant for further improvement of systems for diagnostic control of drives of transport equipment to increase the efficiency and reliability of their work.
Źródło:
Diagnostyka; 2023, 24, 1; art. no. 2023111
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie strumienia poosiowego do oceny stanu technicznego silnika klatkowego w trakcie rozruchu. Część II: zwarcia zwojowe, łączna asymetria obwodu stojana i wirnika
Application of the axial flux to the assessment of the induction motor during the start-up process. Part II: turn-toturn short-circuit, combined asymmetry of stator and rotor
Autorzy:
Tulicki, J.
Sułowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/1201908.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
strumień poosiowy
diagnostyka silnika indukcyjnego
stan przejściowy
uszkodzenie wirnika
zwarcia zwojowe
axial flux
diagnosis induction motor
transient state
rotor cage damage
turn-to-turn short circuits
Opis:
The article presents the research results of the unipolar flux application in the diagnostic of the stator winding and rotor cage of the induction motor. The waveforms of the voltage signals proportional to the axial flux, registered during the starting process, were analyzed. The detailed assessment of the effectiveness of failure distinction for chosen diagnostic signal is made. The application possibility of this algorithm on the testing station and laboratory test bench is shown. The research object is the Sg112M-4 motor of modified construction with built-in measurement coil and changeable rotors of different degree of the cage asymmetry. This motor contains also the terminal with chosen coil turns of the stator phase used to realize the turn-to-turn short circuit. The investigated squirrel cage motor was loaded by the separately excited DC generator allowing to modify the mechanical torque in the whole range of the motor torque characteristic. The paper consists of two parts. The first concerns the detection process of the rotor asymmetry. The second part presents the measurement results and its analysis for the case of stator asymmetry caused by the turn short circuit and the stator and rotor failure at the same time.
W artykule przedstawiono wyniki badań nad zastosowaniem strumienia unipolarnego w diagnostyce uzwojeń stojana oraz klatki wirnika silnika indukcyjnego. Analizowano przebiegi sygnałów napięciowych, proporcjonalne do strumienia poosiowego zarejestrowane podczas rozruchu. Dokonano szczegółowej oceny skuteczności rozróżniania uszkodzeń dl wybranego sygnału diagnostycznego oraz możliwości zastosowania proponowanych algorytmów na stanowisku laboratoryjnym lub stacji prób. Obiektem analiz diagnostycznych był zmodyfikowany konstrukcyjnie silnik Sg112M-4 z zabudowaną cewką pomiarową i wymiennymi wirnikami o różnym stopniu niesymetrii klatki. Silnik ten miał również wyprowadzone odczepy, z wybranych zwojów dwóch cewek faz stojana, umożliwiające wykonanie symulowanych zwarć międzyzwojowych. Badany silnik klatkowy został obciążony prądnicą obcowzbudną, umożliwiającą zmianę momentu mechanicznego w całym zakresie charakterystyki. Artykuł podzielono na dwie części. Pierwsza część dotyczy wykrywania niesymetrii wirnika. W części drugiej przedstawiono wyniki pomiarów i analiz dla niesymetrii stojana spowodowanej zwarciami zwojowymi oraz uszkodzeń stojana i wirnika występujących łącznie.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2016, 2, 110; 155-162
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykrywanie zwarć zwojowych w maszynach elektrycznych na stacji prób z wykorzystaniem cewki do pomiaru strumienia poosiowego
Detection of inter-turn short circuits in electrical machines at a testing station using a coil for measuring the axial flux
Autorzy:
Petryna, J.
Sułowicz, M.
Puzio, Ł.
Dziechciarz, A.
Powiązania:
https://bibliotekanauki.pl/articles/1367752.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
strumień poosiowy
badanie uzwojeń
zwarcia zwojowe
diagnostyka uszkodzeń
modelowanie zwarć
obliczenia polowe
axial flux
winding testing
inter-turn short circuits
diagnosing damages
modeling faults
field calculations
Opis:
The paper presented the results of an AC machine stator tests at the testing station using the coil for measuring the axial flux. The study was conducted for the 75 kW generator for which the replacement of the winding was performed and before impregnating the winding the stator was subjected to testing. At the testing station during interop tests using conventional methods, there was no symptoms of damage to the machine detected. However, a surge test method used later, pointed a winding inter-turn short circuit. Similarly, the inter-turn short circuit of the winding was pointed by proposed and applied by the authors diagnostic method to use a testing coil to measure the axial flux. In the article the method of measurement and interpretation of the results are described in details, and the results of analyzes and field calculations confirming the change in the diagnostic symptoms for a sound machine and the machine with the winding coil inter-turn short circuits are published as well. In conclusion, the article presents a proposal on how to use this method of stator damage detection at a testing station.
W artykule przedstawiono wyniki badań stojana maszyny prądu przemiennego na stacji prób z wykorzystaniem cewki do pomiaru strumienia poosiowego. Badania przeprowadzono dla generatora 75 kW, dla którego wykonano proces wymiany uzwojenia i przed zaimpregnowaniem uzwojeń poddano stojan maszyny testom. Na stacji prób podczas badań międzyoperacyjnych przy stosowaniu tradycyjnych metod nie stwierdzono uszkodzenia maszyny. Jednak na występowanie zwarć zwojowych wskazywała użyta później metoda surge test. Podobnie na występowanie zwarć zwojowych wskazywała zaproponowana przez autorów i zastosowana metoda diagnostyczna z wykorzystaniem cewki do pomiaru strumienia poosiowego. W artykule opisano metodę pomiarów, interpretację uzyskanych wyników oraz zamieszczono wyniki analiz i obliczeń polowych potwierdzających zmianę symptomów diagnostycznych dla maszyny zdrowej i maszyny, w uzwojeniach której występują zwarcia zwojowe. W podsumowaniu artykułu przedstawiono propozycję, w jaki sposób stosować tę metodę badań do wykrywania uszkodzeń stojana na stacji prób.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2015, 2, 106; 185-190
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-9 z 9

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies