Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "zuzycie srednie" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Average fuel consumption by a ship on a sales line in statistical weather conditions
Autorzy:
Szelangiewicz, T.
Żelazny, K.
Powiązania:
https://bibliotekanauki.pl/articles/27315961.pdf
Data publikacji:
2018
Wydawca:
STE GROUP
Tematy:
zużycie paliwa
prędkość statku
moc napędowa
linie żeglugowe
średnie statystyczne parametry pogodowe
fuel consumption
ship speed
propulsion power
shipping lines
average statistical weather parameters
Opis:
During operation of the ship, fuel consumption and associated emissions are very important for economic and ecological reasons. The fuel consumption is greatly influenced by the choice of shipping route, weather conditions on these routes and engine control criteria. The article presents its own algorithm for forecasting ship operation parameters, including fuel consumption on selected shipping routes for average, statistical (seasonal) weather parameters occurring on these routes. It shows what factors have the main impact on fuel consumption and how you can affect fuel consumption during the cruise in changing weather conditions.
Źródło:
New Trends in Production Engineering; 2018, 1, 1; 573-579
2545-2843
Pojawia się w:
New Trends in Production Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Średnie zużycie zimnej i ciepłej wody w budynkach wielorodzinnych
Average consumption of water cold and warm in the multifamily buildings
Autorzy:
Bugajski, P.
Powiązania:
https://bibliotekanauki.pl/articles/59984.pdf
Data publikacji:
2009
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
budynki wielorodzinne
zuzycie wody
woda ciepla
woda zimna
jednostkowe zuzycie wody
zuzycie srednie
zuzycie rzeczywiste
Opis:
W artykule przedstawiono wyniki badań dotyczących zużycia wody w czterech budynkach wielorodzinnych w wieloleciu 2004–2008. Do badań wytypowano budynki mieszkalne o różnej liczbie lokali mieszkalnych oraz o różnej liczbie zameldowanych mieszkańców. Wszystkie mieszkania w poszczególnych blokach są w pełni i komfortowo wyposażone w wewnętrzną instalację wodociągowo- kanalizacyjną. Woda zimna do mieszkań doprowadzana jest z Miejskiego Przedsiębiorstwa Wodociągów i Kanalizacji S.A. w Krakowie. Natomiast woda ciepła dostarczana jest z Miejskiego Przedsiębiorstwa Energetyki Cieplnej S.A. w Krakowie. W każdym lokalu mieszkalnym zainstalowane były wodomierze wody zimnej i ciepłej. Zainstalowane wodomierze mają klasę dokładności metrologicznej B, a błąd ich pomiaru wynosi ± 2%. Celem badań było określenie wielkości jednostkowego zużycia wody zimnej i ciepłej w czterech budynkach wielorodzinnych zlokalizowanych na osiedlu Kurdwanów w Krakowie. Ilość zużywanej wody zimnej i ciepłej odczytywano z wodomierzy skrzydełkowych z częstotliwością raz na trzy miesiące, a następnie obliczano zużycie w przeliczeniu na mieszkańca w ciągu doby. W okresie tym przeanalizowano wielkość zużycia całkowitego i porównano do aktualnie obowiązujących wytycznych zawartych w Rozporządzeniu z dnia 14 stycznia 2002 roku, dotyczącym przeciętnych norm zużycia wody przez mieszkańców. Porównanie miało na celu wykazanie, czy faktyczne zużycie wody jest porównywalne ze zużyciem przyjmowanym w wytycznych. We wszystkich analizowanych budynkach wielorodzinnych odnotowano dużo mniejsze zużycie wody od wartości podawanych w aktualnie obowiązujących wytycznych. W okresie 5. lat pomiarów zużycia wody zimnej i ciepłej stwierdzono, iż średnio jeden mieszkaniec w ciągu doby zużywał od 54,7 dm3 w bloku „A” do 72,4 dm3 w bloku „C”. Różnica pomiędzy rzeczywistym zużyciem wody a przyjmowanym w obowiązujących wytycznych wynosiła od 63,5% do 51,7%. Jest to kolejny przykład, jak dalece aktualne wytyczne dotyczące zużycia wody przez ludzi odbiegają od rzeczywistości. Wyniki analizy zużycia wody przedstawione w niniejszym artykule potwierdzają doniesienia literaturowe o niskim zużyciu wody przez mieszkańców zamieszkujących mieszkania mające wodę zimną, ciepłą oraz system odprowadzania ścieków.
The paper presents the results of the research on the water usage in four multifamily buildings in the multi-year period of 2004–2008. The objects of the research were the residential buildings with different amounts of premises and different amounts of tenants. All the flats in each block are fully and comfortably equipped with the internal water supply and sewerage systems. The cold water is delivered to the flats from The Municipal Water Supply and Sewerage Company in Krakow. On the other hand, warm water is delivered from The Municipal District Heating Enterprise in Krakow. In each flat cold and warm water-meters were installed. The water-meters’ metrological accuracy class is B and their measurement error is ± 2%. The aim of the research was to define the amount of the unitary cold and warm water usage in four multifamily buildings located in Kurdwanow district in Krakow. The amount of the consumed cold and warm water was read from the vane - wheel water-meters once in three months and then the usage was calculated for one tenant per day. In this period the amount of the total water usage was analyzed and compared to the current directives from the Regulation from 14th January 2002 concerning the average standards of the water usage for tenants. The comparison aimed at showing if the actual water usage is comparable to the water usage from the directives. In all analyzed buildings the water usage was much lower in comparison to the amounts given by the current directives. In the 5 year period of the water usage analyzes, it was ascertained that on average one tenant used from 54,7 dm3 in building „A” to 72,4 dm3 of water in building „C” per one day. The difference between the actual water usage and the one accepted by the directives was from 63,5% to 51,7%. This can be another example of how the regulations on water usage are different from the reality. The results of the analyses on the water usage by the tenants who live in the comfortable flats, fully equipped with the water supply and sewerage systems, presented in this article confirmed the literature data concerning the low water usage.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2009, 09
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wstępna analiza średniego zużycia wody w jednorodzinnych gospodarstwach domowych
A preliminary analysis of the average consumption of cold water in single-family houshold
Autorzy:
Paweska, K.
Bawiec, A.
Wlodek, S.
Smaga, E.
Powiązania:
https://bibliotekanauki.pl/articles/62184.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
gospodarstwa domowe
zuzycie wody
zuzycie jednostkowe
woda pitna
zuzycie srednie
Opis:
W pracy przedstawiono średnie zużycie zimnej wody w gospodarstwach domowych zlokalizowanych w miejscowości Gorlice (woj. małopolskie) w ujęciu miesięcznym oraz dobowy rozkład zużycia wody w gospodarstwie domowym zlokalizowanym w Ząbkowicach Śląskich (woj. dolnośląskie). Gospodarstwa domowe objęte analizą zużycia wody umieszczone były w budynkach jednorodzinnych z poddaszem użytkowym. Wszystkie budynki były obiektami zabudowy niskiej do 12 metrów nad poziom terenu wyposażone w V klasę instalacji wodociągowo – kanalizacyjnych. Dla każdego z obiektu wyznaczono średnie dobowe zużycie wody, które kształtowało się w przedziale 0,11 – 0,18 m3 ×M-1 ×d-1. Najwyższe średnie dobowe zużycie wody obserwowano w budynku zlokalizowanym w Ząbkowicach Śląskich.
This paper presents the average consumption of cold water in households located in the town of Gorlice (southern Poland) on a monthly basis and daily distribution of water consumption in households located in the Ząbkowice Śląskie (Lower Silesia). Households included in the analysis of water use were placed in single-family houses with attic. All the buildings were objects that were built low (about 12 meters above ground level) with a V class of water supply installations. For each building average daily water consumption was determined which ranged in the range of 0.11 – 0.18 m3 × M-1 × d-1. The highest average daily water consumption was observed in the building located in the Ząbkowice Śląskie.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2013, 1/IV
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies