Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "zero-sequence voltage" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Influence of magnetic saturation effects on the fault detection of induction motors
Autorzy:
Drozdowski, P.
Duda, A.
Powiązania:
https://bibliotekanauki.pl/articles/141384.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
induction motors
fault detection
saturation
zero-sequence voltage
Opis:
In this paper, the influence of impact damage to the induction motors on the zero-sequence voltage and its spectrum is presented. The signals detecting the damages result from a detailed analysis of the formula describing this voltage component which is induced in the stator windings due to core magnetic saturation and the discrete displacement of windings. Its course is affected by the operation of both the stator and the rotor. Other fault detection methods, are known and widely applied by analysing the spectrum of stator currents. The presented method may be a complement to other methods because of the ease of measurements of the zero voltage for star connected motors. Additionally, for converter fed motors the zero sequence voltage eliminates higher time harmonics displaced by 120 degrees. The results of the method application are presented through measurements and explained by the use of a mathematical model of the slip-ring induction motor.
Źródło:
Archives of Electrical Engineering; 2014, 63, 3; 489-506
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena parametrów asymetrii dla składowej zerowej w sieci średniego napięcia
Assessment of asymmetry parameters for zero sequence component in the medium voltage network
Autorzy:
Marciniak, Lubomir
Powiązania:
https://bibliotekanauki.pl/articles/266760.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
sieci SN
sieci średniego napięcia
składowe symetryczne zerowe
ocena asymetrii
MV networks
medium voltage networks
zero-sequence component
asymmetry assessment
Opis:
W pracy wyprowadzono parametryczne zależności pozwalające szacować wielkości charakteryzujące asymetrię napięcia, prądów, mocy i admitancji dla podstawowej i wyższych harmonicznych składowych symetrycznych zerowych. Przeprowadzono analizę porównawczą wyników otrzymanych z wyrażeń analitycznych z wynikami otrzymanymi z symulacji pracy sieci SN i wykazano wystarczającą ich zbieżność. Wyprowadzone wzory mogą być stosowane przy określaniu nastaw zabezpieczeń ziemnozwarciowych.
In medium voltage networks there is an asymmetry of the capacitance and conductance parameters for the zero sequence symmetrical component, which leads to the appearance of the asymmetry voltage for the zero sequence component, earth currents, asymmetry power and asymmetry admittance for zero sequence components occurring in the normal state of network operation and affecting earth fault protection settings and limiting their sensitivity. In order to ensure a sensitive setting of earth fault protections, it is necessary to properly estimate the mentioned quantities. Parametric relationships were derived in the paper, allowing to estimate the quantities characterizing the asymmetry for fundamental and higher harmonics. The resulting formulas contain all relevant network parameters: rated voltage Un, share of the specified harmonic kh, compensation detuning s, network and line capacitances for zero sequence component C0, C01 and their maximum deviations ΔC0, ΔC01, damping d0, system inductance Ls. A comparative analysis of the results obtained from analytical expressions with the results obtained from the simulation of the MV network was carried out. The sufficient convergence of results indicating the possibility of using the formulas when determining the settings of earth fault protections was demonstrated.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 67; 39-42
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design of new robust backstepping control for three-phase grid-connected fourleg source voltage PWM converters
Autorzy:
Chebabhi, Ali
Kessal, Abdelhalim
Powiązania:
https://bibliotekanauki.pl/articles/2203363.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
three-phase grid-connected four-leg voltage source rectifiers
GC-FLVSR
Robust Backstepping Control
RBSC
parameters uncertainties
harmonic
Zero Sequence Currents
ZSCs
Unit Power Factor
UPF
Opis:
Due to high performance demands of grid-connected pulse-width modulation (PWM) converters in power applications, backstepping control (BSC) has drawn wide research interest for its advantages, including high robustness against parametric variations and external disturbances. In order to guarantee these advantages while providing high static and dynamic responses, in this work, a robust BSC (RBSC) with consideration of grid-connected PWM converter parameter uncertainties is proposed for three-phase grid-connected four-leg voltage source rectifiers (GC-FLVSR). The proposed RBSC for GC-FLVSR is composed of four independent controllers based on the Lyabonov theory that control DC bus voltage and input currents simultaneously. As a result, unit power factor, stable DC-bus voltage, sinusoidal four-leg rectifier input currents with lower harmonics and zero-sequence (ZS), and natural currents can be accurately achieved. Furthermore, the stability and robustness against load, DC capacitor, and filter inductance variations can be tested. The effectiveness and superiority of the proposed RBSC compared to the PI control (PIC) have been validated by processor-in-the-loop (PIL) co-simulation using the STM32F407 discovery-development-board as an experimental study.
Źródło:
Metrology and Measurement Systems; 2023, 30, 1; 65--82
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of network voltages to insulation monitoring in unearthed AC circuits with rectifiers
Wykorzystanie napięć sieci do kontroli izolacji obwodów AC IT z prostownikami
Autorzy:
Olszowiec, P.
Powiązania:
https://bibliotekanauki.pl/articles/155121.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
unearthed AC networks
rectifiers
earth fault voltages and currents
phase voltage mean value
phase voltages zero sequence component
sieci izolowane AC
prostowniki
napięcia i prądy doziemne
wartość średnia napięcia fazowego
składowa zerowa napięć fazowych
Opis:
Maximum values of possible earth fault currents in low voltage unearthed AC networks supplying DC circuits through diode rectifiers are critical for evaluation of possible electric shock and fire hazards caused by insulation condition deterioration. A method for analytical determination of time functions of earth fault parameters, i.e. wire-to-earth voltages and currents is presented in the paper. Application of two characteristic parameters i.e. the phase voltage mean value and the phase voltages zero sequence component to insulation condition evaluation is discussed. A new method exploiting the phase voltages mean value for insulation resistance monitoring is presented.
Maksymalne wartości prądów zwarć z ziemią w sieciach izolowanych AC zasilających obwody DC przez prostowniki diodowe decydują o ewentualnych ryzykach porażenia osób, pożaru i wybuchu. W artykule przedstawiono metodę analitycznego wyznaczania przebiegów czasowych parametrów ziemnozwarciowych tj. napięć i prądów doziemnych; zagadnienie to było dotychczas pomijane w dostępnej literaturze. Wyznaczono zależności dla charakterystycznego parametru układów AC/DC IT, którym jest wartość średnia napięć fazowych strony AC. Omówiono przydatność tej wielkości dla kontroli izolacji tych sieci oraz lokalizacji doziemień. W oparciu o najczęstsze w praktyce przypadki pokazano, że składowa zerowa napięć fazowych spełnia funkcję sygnalizacji pogorszenia stanu izolacji praktycznie jedynie dla strony AC (rys. 4). Przy uszkodzeniach izolacji po stronie DC napięcie tej składowej w nieznacznym stopniu zależy od rezystancji zwarcia doziemnego. Z użyciem wartości zastępczej rezystancji izolacji całego układu AC/DC IT oszacowano maksymalny poziom prądu upływu decydujący o bezpieczeństwie porażeniowym i pożarowym sieci. W artykule zaproponowano nową metodę wyznaczania wartości zastępczej rezystancji izolacji całego układu. Procedura z użyciem dodatkowego rezystora testowego obejmuje pomiary wartości średniej napięć fazowych, na bazie których oblicza się wartość szukanego parametru. Oprócz prostoty i braku wrażliwości na pojemności doziemne metoda wyróżnia się uniwersalnością, gdyż uwzględnia upływności izolacji całej sieci AC/DC IT.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 12, 12; 1252-1255
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies