Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "zero sequence currents" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Design of new robust backstepping control for three-phase grid-connected fourleg source voltage PWM converters
Autorzy:
Chebabhi, Ali
Kessal, Abdelhalim
Powiązania:
https://bibliotekanauki.pl/articles/2203363.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
three-phase grid-connected four-leg voltage source rectifiers
GC-FLVSR
Robust Backstepping Control
RBSC
parameters uncertainties
harmonic
Zero Sequence Currents
ZSCs
Unit Power Factor
UPF
Opis:
Due to high performance demands of grid-connected pulse-width modulation (PWM) converters in power applications, backstepping control (BSC) has drawn wide research interest for its advantages, including high robustness against parametric variations and external disturbances. In order to guarantee these advantages while providing high static and dynamic responses, in this work, a robust BSC (RBSC) with consideration of grid-connected PWM converter parameter uncertainties is proposed for three-phase grid-connected four-leg voltage source rectifiers (GC-FLVSR). The proposed RBSC for GC-FLVSR is composed of four independent controllers based on the Lyabonov theory that control DC bus voltage and input currents simultaneously. As a result, unit power factor, stable DC-bus voltage, sinusoidal four-leg rectifier input currents with lower harmonics and zero-sequence (ZS), and natural currents can be accurately achieved. Furthermore, the stability and robustness against load, DC capacitor, and filter inductance variations can be tested. The effectiveness and superiority of the proposed RBSC compared to the PI control (PIC) have been validated by processor-in-the-loop (PIL) co-simulation using the STM32F407 discovery-development-board as an experimental study.
Źródło:
Metrology and Measurement Systems; 2023, 30, 1; 65--82
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Control of open-end induction motor by multi-objective GA based selective harmonic elimination PWM to reduce zero sequence currents and torque ripples
Autorzy:
Kumar, K. Kalyan
Anuradha, K.
Suryakalvathi, M.
Powiązania:
https://bibliotekanauki.pl/articles/41179745.pdf
Data publikacji:
2023
Wydawca:
Politechnika Warszawska, Instytut Techniki Cieplnej
Tematy:
open-end winding induction machine
zero sequence currents
torque ripple
selective harmonic elimination
triplen harmonics
maszyna indukcyjna
uzwojenie otwarte
tętnienie momentu obrotowego
selektywna eliminacja harmonicznych
potrójne harmoniczne
Opis:
A double inverter powered induction motor with open stator winding has few benefits, including excessive error forbearance functionality, great flexibility and lesser rating of DC input voltage etc. For this Configuration, two types of Modules can be implemented: they are Non-Isolated DC link and Isolated DC link. In these two, Non-Isolated DC link is a good choice due to effective DC-link utilization and ruggedness, which is very beneficial in many applications. However, this module produces more zero sequence currents (Z-SC) by means of common mode (CMMD) voltage, which flows through DC bus. The circulation of Z-SC must be as little as possible since it merely rises the amplitude of currents in all phases. High ripple frequency of currents and torque, in addition results in extra loss, which not only reduces the efficiency, but influences loading ability and quickens the aging of drive. The Triplen harmonics can be defined as harmonics with integer of three times the frequency at fundamental, when they are in Phase in all Phases forms the Z-SC. In this paper, a novel SHE method is chosen to target Triplen harmonics in Single DC Source Module (Non- Isolated) and holding preferred fundamental quantity, which aids in improving the torque handling ability of the motor. In addition, the investigation of dual inverter fed OEW-IM with both common DC source as well as separate DC sources is also explored in the SHE for different number of switching angles and variable Modulation Index (MI) towards the torque ripples and Z-SC reduction given. The foremost challenge related to the SHE method is resolving a set of higher order nonlinear equations with a number of variables. A Multi-objective GA method is provided for that challenge which effects the reduction in Z-SC so that torque ripples will be minimized. Moreover, the novel SHE method reduces the number of harmonics better than the conventional SHE, which further decreases TH-D with decent fundamental quantity. For validation, the essential mathematical formulations and simulation results are presented.
Źródło:
Journal of Power Technologies; 2023, 103, 1; 72-87
1425-1353
Pojawia się w:
Journal of Power Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of network voltages to insulation monitoring in unearthed AC circuits with rectifiers
Wykorzystanie napięć sieci do kontroli izolacji obwodów AC IT z prostownikami
Autorzy:
Olszowiec, P.
Powiązania:
https://bibliotekanauki.pl/articles/155121.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
unearthed AC networks
rectifiers
earth fault voltages and currents
phase voltage mean value
phase voltages zero sequence component
sieci izolowane AC
prostowniki
napięcia i prądy doziemne
wartość średnia napięcia fazowego
składowa zerowa napięć fazowych
Opis:
Maximum values of possible earth fault currents in low voltage unearthed AC networks supplying DC circuits through diode rectifiers are critical for evaluation of possible electric shock and fire hazards caused by insulation condition deterioration. A method for analytical determination of time functions of earth fault parameters, i.e. wire-to-earth voltages and currents is presented in the paper. Application of two characteristic parameters i.e. the phase voltage mean value and the phase voltages zero sequence component to insulation condition evaluation is discussed. A new method exploiting the phase voltages mean value for insulation resistance monitoring is presented.
Maksymalne wartości prądów zwarć z ziemią w sieciach izolowanych AC zasilających obwody DC przez prostowniki diodowe decydują o ewentualnych ryzykach porażenia osób, pożaru i wybuchu. W artykule przedstawiono metodę analitycznego wyznaczania przebiegów czasowych parametrów ziemnozwarciowych tj. napięć i prądów doziemnych; zagadnienie to było dotychczas pomijane w dostępnej literaturze. Wyznaczono zależności dla charakterystycznego parametru układów AC/DC IT, którym jest wartość średnia napięć fazowych strony AC. Omówiono przydatność tej wielkości dla kontroli izolacji tych sieci oraz lokalizacji doziemień. W oparciu o najczęstsze w praktyce przypadki pokazano, że składowa zerowa napięć fazowych spełnia funkcję sygnalizacji pogorszenia stanu izolacji praktycznie jedynie dla strony AC (rys. 4). Przy uszkodzeniach izolacji po stronie DC napięcie tej składowej w nieznacznym stopniu zależy od rezystancji zwarcia doziemnego. Z użyciem wartości zastępczej rezystancji izolacji całego układu AC/DC IT oszacowano maksymalny poziom prądu upływu decydujący o bezpieczeństwie porażeniowym i pożarowym sieci. W artykule zaproponowano nową metodę wyznaczania wartości zastępczej rezystancji izolacji całego układu. Procedura z użyciem dodatkowego rezystora testowego obejmuje pomiary wartości średniej napięć fazowych, na bazie których oblicza się wartość szukanego parametru. Oprócz prostoty i braku wrażliwości na pojemności doziemne metoda wyróżnia się uniwersalnością, gdyż uwzględnia upływności izolacji całej sieci AC/DC IT.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 12, 12; 1252-1255
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies