Tytuł:
The impact of the method of anchoring the façade texture layer on the durability of is fixing
Autorzy:
Tomaszewski, D.
Powiązania:
https://bibliotekanauki.pl/articles/111035.pdf
Data publikacji:
2018
Wydawca:
Centrum Rzeczoznawstwa Budowlanego Sp. z o.o.
Tematy:
anchorage
façade
texture layer
durability
fastening
zamocowanie
fasada
trwałość
Opis:
The subject of this article is to test the shear strength of the anchorage, based on diagonal brackets. The tests were carried out on six three-layer samples with a size of 40 x 20 x 17 cm. The samples have been designed to represent a section of a three-layer wall in large-plate buildings and made on an adequate scale with wire mesh reinforcement of Ø 3 mm and a mesh size of 3 x 3 cm. In three samples Ø 6 mm Ø hangers with a diagonal support arm were concreted, and in three others with a „V” shape. The hangers were interlocked with Ø 6 mm anchoring rods to stabilize the mesh embedded in the texture layer. The samples were made of concrete of class C 12/15, while the inner layer was thermal insulation in the form of expanded polystyrene. Tests of the resistance of the pull-out anchors were carried out using Hydrajaws 2008 Pull-out Tester. Each anchor was tested individually. Bonded anchors M 12 were used. The results were summarized in 15 tests (9 diagonal anchors and 6 points). The tests were carried out until the anchor fixings were destroyed. The increase in force during a single attempt was determined on the basis of a video recording in relation to each attempted extraction. When attempts were made to remove the diagonal anchors, steel brackets and angular wooden washers were used to achieve the effect of axial removal of anchors. The role of diagonal anchors in the work of the three-layer element has been discussed.
Źródło:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych; 2018, 1-2; 23-26
2450-1859
2450-8721
Pojawia się w:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania na rozciąganie splotów sprężających w Laboratorium Badań Wytrzymałościowych ITB
Experimental tensile test of strands for prestressing of concrete in Strength Testing Laboratory of BRI
Autorzy:
Szwaranowicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/183266.pdf
Data publikacji:
2004
Wydawca:
Instytut Techniki Budowlanej
Tematy:
splot sprężający
rozciąganie
badanie
metoda pomiaru
maszyna wytrzymałościowa
zamocowanie
automatyzacja
SOLARTRON
odkształcenie
Opis:
Przedstawiono metodę przeprowadzenia badań wytrzymałościowych na rozciąganie splotów do konstrukcji sprężonych zgodnie z normami europejskimi. Opisano sposób dostosowania maszyny wytrzymałościowej do przeprowadzenia badań oraz metodę określenia E, R0,1 i Agt.
This paper deals with the tensile test methods of strands for prestressing of concrete according to the European standards. Adaptation of testing machine and other equipment is described as well as the method of determination of E, R0,1 i Agt.
Źródło:
Prace Instytutu Techniki Budowlanej; 2004, R. 33, nr 4, 4; 45-54
0138-0796
Pojawia się w:
Prace Instytutu Techniki Budowlanej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the retention characteristics of various stud attachment systems for implant retained overdenture
Autorzy:
Gonuldas, F.
Tokar, E.
Ozturk, C.
Powiązania:
https://bibliotekanauki.pl/articles/306253.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
implant
zamocowanie
proteza
retencja
overdenture
implant-supported dental prosthesis
denture precision attachment
retention
Opis:
The purpose of the study was to analyze and compare retention characteristics of different stud attachments including a standard and two low profile attachments on two implant embedded test models. Methods: Three different stud attachment systems (Ball attachment and two different low profile stud attachments – Equator and Locator) were used in this study. Two dental implants were placed vertically into a custom-made acrylic resin block within a 22 mm distance. Strong and soft nylon inserts of each attachment system were tested using cyclic dislodgement test for 24 months simulation. Maximum forces during the test were recorded and 10 consecutive data at baseline, 1st to 24th months were analyzed. Repeated measures ANOVA and post-hoc Tukey’s test ( p 0.05) were used for statistical analysis. Results: Retentive forces of the tested attachments varied from 30.7 to 93.75 N at the baseline. The highest initial mean retention (93.75 N) was observed in Group LC (locator attachment with clear nylon inserts) and the lowest initial mean retention (30.7 N) was detected in both Group BO (ball attachment with orange nylon inserts) and Group EY (equator with yellow nylon inserts). After the 24 months simulation, locator groups illustrated more light retention than other tested attachment systems. Conclusions: All tested attachment systems showed a significant decrease in retention value at the end of the simulated period. The locator attachment had significantly higher reduction in retention values compared to other low profile stud attachment equator and ball attachment.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 4; 135-141
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ warunków brzegowych na formę odkształceń drgań własnych i wymuszonych stojana silnika BLDC. Analiza numeryczna
Influence of boundary conditions on shape of deformation of free and forced vibrations of the stator structure of BLDC motor - numerical analysis
Autorzy:
Podhajecki, J.
Szymaniec, S.
Powiązania:
https://bibliotekanauki.pl/articles/1813570.pdf
Data publikacji:
2012
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
silnik bezszczotkowy prądu stałego z magnesami trwałymi
drgania
siły magnetyczne
metoda elementów skończonych
warunki brzegowe
zamocowanie
Opis:
This article presents research on the influence of the mounting on shape of deformation for free and forced vibrations in Brushless Direct Current Motor (BLDC) with permanent magnets. The status of the problem and numerical study of calculations for free and forced vibrations for different boundary conditions are shown.
Źródło:
Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych Politechniki Wrocławskiej. Studia i Materiały; 2012, 66, 32; 279-284
1733-0718
Pojawia się w:
Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych Politechniki Wrocławskiej. Studia i Materiały
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ niektórych błędów montażowych i rozwiązań materiałowych na jakość zamocowań w konstrukcjach betonowych
The impact of certain assembly errors and material solutions on the quality of fixtures in concrete constructions
Autorzy:
Konieczny, K.
Dudek, D.
Powiązania:
https://bibliotekanauki.pl/articles/160328.pdf
Data publikacji:
2018
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
konstrukcja betonowa
zamocowanie
jakość
błąd montażowy
rozwiązanie materiałowe
concrete structure
fixing
quality
assembly error
material solution
Opis:
Obecnie stosowane systemy zamocowań w konstrukcjach betonowych można podzielić na te, które są wykonane w trakcie betonowania konstrukcji, oraz na zamocowania w gotowych podłożach. Najczęściej stosowane są łączniki rozporowe, tworzywowo-metalowe oraz wklejane. Ich konstrukcja umożliwia przenoszenie obciążeń rozciągających, ścinających i złożonych. Łączniki te są tak zaprojektowane, by przez cały zamierzony czas użytkowania spełniały swoje zadania w zakresie użytkowalności, nośności i stateczności, bez istotnego obniżenia swojej przydatności oraz nadmiernych, nieprzewidzianych kosztów eksploatacji.
Currently used fixture systems in concrete constructions can be divided into fixtures performed during concreting of construction and fixtures in finished substrates. The most common are universal sleeve anchors, plastic-and-metal anchors as well as inserted anchors. Their construction makes it possible to transfer tensile, cut and complex loads. These connectors are designed in such a way so as to fulfil their tasks in the scope of usability, load-bearing capacity and stability, without significant reduction of their usefulness and excessive unforeseen costs of exploitation during the entire intended period of use.
Źródło:
Przegląd Budowlany; 2018, 89, 12; 41-46
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Niezamierzony efekt częściowego zamocowania stropów ze sprężonych płyt kanałowych
Autorzy:
Derkowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/162629.pdf
Data publikacji:
2014
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
strop
płyta strunobetonowa
płyta kanałowa
podparcie
zamocowanie
nośność na ścinanie
floor
prestressed concrete slab
hollow core slab
support
fixing
shear load capacity
Źródło:
Przegląd Budowlany; 2014, R. 85, nr 1, 1; 24-27
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ temperatury na nośność zamocowań tworzywowo-metalowych łączników rozporowych w betonie
Effect of temperature on the load-bearing capacity of plastic-and-metal anchors in concrete
Autorzy:
Knap, P.
Powiązania:
https://bibliotekanauki.pl/articles/162202.pdf
Data publikacji:
2011
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
łącznik rozporowy
łącznik tworzywowo-metalowy
nośność
temperatura
podłoże betonowe
badanie laboratoryjne
zamocowanie
ETAG 020
shield anchor
plastic-and-metal anchor
bearing capacity
temperature
substrate
Opis:
Stosowane obecnie w budownictwie nowoczesne rozporowe łączniki tworzywowo-metalowe przeznaczone są do pracy w rożnych podłożach oraz w różnych warunkach środowiskowych. Wymagania, jakie powinny zostać spełnione przez łączniki tworzywowo-metalowe zostały m.in. opisane w dokumencie Europejskiej Organizacji ds. Aprobat Technicznych (EOTA) "Wytyczne dla europejskich aprobat technicznych - ETAG 020".
The modern plastic-and-metal anchors currently used in the construction industry are intended to function in a variety of bases and environmental conditions. Requirements with which they are expected to comply are set out, among others, in the European Organization for Technical Approvals (EOTA) document "Guidelines for European Technical Approval - ETAG 020".
Źródło:
Przegląd Budowlany; 2011, R. 82, nr 11, 11; 30-33
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of support closed section ribs on the critical moment for lateral torsional buckling of steel beams
Wpływ żeber podporowych o przekroju zamkniętym na moment krytyczny zwichrzenia belek stalowych
Autorzy:
Piotrowski, R.
Szychowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/402434.pdf
Data publikacji:
2018
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
critical moment for lateral torsional buckling
closed section ribs
elastic restraint against warping
moment krytyczny zwichrzenia
żebra o przekroju zamkniętym
sprężyste zamocowanie przeciw spaczeniu
Opis:
The study presents the results of theoretical investigations into the effect produced by support closed section ribs on the critical moment for lateral torsional buckling (Mcr) of bisymmetric I-beams. Elastic restraint against warping, at the site of support, was provided by closed section ribs made from selected rolled profiles (longitudinally cut circular tubes, angles, and channels). Detailed calculations were made for beams under uniform load applied to the top flange of the section. The results obtained in the investigations were compared with the values obtained for beams with end plate. The analysis was conducted of the impact of ribs on the increase in the critical resistance of beams. Analytically estimated critical moments for lateral torsional buckling were verified using FEM tools (LTBeamN, Abaqus).
W pracy przedstawiono wyniki badań teoretycznych wpływu podporowych żeber zamkniętych na moment krytyczny zwichrzenia (Mcr) belek o bisymetrycznym przekroju dwuteowym. Sprężyste zamocowanie przeciw spaczeniu w miejscu podparcia stanowiły żebra o przekroju zamkniętym, które wykonano z wybranych profili walcowanych (podłużnie rozcięte rury, kątowniki, ceowniki). Obliczenia szczegółowe wykonano dla belek obciążonych równomiernie obciążeniem przyłożonym do półki górnej przekroju. Uzyskane wyniki porównano z wartościami otrzymanymi dla belek z żebrowaniem w postaci blachy czołowej. Przeprowadzono analizę wpływu żeber na zwiększenie nośności krytycznej belek. Oszacowane analitycznie momenty krytyczne zwichrzenia zweryfikowano za pomocą MES (LTBeamN, Abaqus).
Źródło:
Structure and Environment; 2018, 10, 1; 5-18
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Local buckling of one-side elastically restrained thin-walled cross-section wall under longitudinal stress variation
Wyboczenie lokalne jednostronnie sprężyście zamocowanej ścianki przekroju cienkościennego przy wzdłużnej zmienności naprężeń
Autorzy:
Szychowski, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/27322569.pdf
Data publikacji:
2023
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
thin-walled member
critical stress of local buckling
elastic restraint
longitudinal stress variation
approximation formulas
element cienkościenny
naprężenie krytyczne wyboczenia lokalnego
sprężyste zamocowanie
wzdłużna zmienność naprężeń
wzory aproksymacyjne
Opis:
In cold-formed thin-walled cross-sections, complex phenomena, related to local and distortional buckling of slender walls containing edge fold stiffeners, occur. In order to determine the design resistance of such a cross-section in the post-buckling range, it is necessary to determine the critical stress of local buckling for individual walls. On this basis, the corresponding effective widths are determined. Subsequently, the distortional buckling effect is taken into account, typically by reducing the thickness of the substitute cross-section of the stiffener. The paper presents approximation formulas of plate buckling coefficients (k*) that are used to calculate critical local buckling stress for technically crucial stress distributions. The full range of variation of the index of elastic fixity of the longitudinal edge of the thin-walled cross-section was considered. The coefficients were determined for a more accurate, relative to Eurocode 3, computational model. Both the effect of reciprocal elastic restraint of component walls of the cross-section and the effect of longitudinal stress variation, which occurs in transversely bent beams, were taken into account.
W profilowanych na zimno przekrojach cienkościennych występują złożone zjawiska związane z wyboczeniem lokalnym i dystorsyjnym smukłych ścianek zawierających krawędziowe odgięcia usztywniające. W celu wyznaczenia nośności obliczeniowej takiego przekroju w zakresie nadkrytycznym należy wyznaczyć naprężenia krytyczne wyboczenia lokalnego dla poszczególnych ścianek. Na tej podstawie wyznacza się odpowiednie szerokości efektywne. W kolejnym kroku uwzględnia się efekt wyboczenia dystorsyjnego, najczęściej poprzez redukcję grubości tzw. zastępczego przekroju usztywnienia. W pracy przedstawiono wzory aproksymacyjne płytowych współczynników wyboczeniowych (k*) służące do obliczania naprężeń krytycznych wyboczenia lokalnego dla technicznie ważnych rozkładów naprężeń. Uwzględniono pełny zakres zmienności wskaźnika sprężystego utwierdzenia krawędzi podłużnej półki przekroju cienkościennego. Współczynniki wyznaczono dla dokładniejszego, w stosunku do Eurokodu 3, modelu obliczeniowego. Uwzględniono zarówno efekt wzajemnego sprężystego zamocowania ścianek składowych przekroju, jak również występujący w poprzecznie zginanych belkach efekt wzdłużnej zmienności naprężeń.
Źródło:
Structure and Environment; 2023, 15, 4; 244--252
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Lokalne wyboczenie ścianki wspornikowej elementu cienkościennego przy wzdłużnej i poprzecznej zmienności naprężeń
Local buckling of cantilever wall of thin-walled member with longitudinal and transverse stress variation
Autorzy:
Szychowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/390180.pdf
Data publikacji:
2015
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
pręty cienkościenne
przekrój otwarty
ścianki wspornikowe
sprężyste zamocowanie
wzdłużna zmienność naprężeń
poprzeczna zmienność naprężeń
thin-walled bars
open cross section
cantilever wall
elastically restrained
longitudinal stress variation
transverse stress variation
Opis:
W pracy przedstawiono wyniki badań stateczności sprężyście zamocowanych ścianek (płyt) wspornikowych przy wzdłużnej i poprzecznej zmienności naprężeń. Przyjęto liniowy rozkład naprężeń w kierunku szerokości ścianki (płyty) oraz liniowy lub nieliniowy (wg paraboli 2. stopnia) rozkład naprężeń na jej długości. Wyznaczono wykresy współczynników wyboczeniowych (k) dla różnie podpartych i różnie obciążonych płyt wspornikowych, których nie znaleziono w literaturze.
The paper presents results of the investigation into the stability of elastically restrained cantilever walls (plates) with longitudinal and transverse stress variation. A linear distribution of stresses in the direction of the wall (plate) width and the linear or nonlinear (in accordance with parabola 20) distribution of stresses along the wall length were assumed. Plots of plate buckling coefficients (k) for variously supported and variously loaded cantilever plates, which are not found in the literature, were determined.
Źródło:
Budownictwo i Architektura; 2015, 14, 2; 113-121
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza pracy balustrady zamocowanej w zawilgoconej konstrukcji murowej budynków z początku lat 80. XX w.
Analysis of the work of the fixed railing in a damp structure masonry of buildings from the beginning of the years 1980s
Autorzy:
Ksit, Barbara
Powiązania:
https://bibliotekanauki.pl/articles/2160677.pdf
Data publikacji:
2022
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
balustrada
zamocowanie
loggia
konstrukcja murowa
zawilgocenie
awaria
budynek wielkopłytowy
błąd wykonawstwa
błąd projektowania
model obliczeniowy
analiza statyczna
balustrade
fastening
masonry structure
moisture content
failure
large-panel building
execution fault
design fault
calculation model
static analysis
Opis:
Materiały budowlane absorbują kapilarnie wilgoć, gdy mają z nią bezpośrednią styczność. W artykule przedstawiono analizę statyczną mocowania zabezpieczających barier w uszkodzonych loggiach budynków 5-kondygnacyjnych, wykonanych w technologii uprzemysłowionej z elementami technologii tradycyjnej, zrealizowanych w latach osiemdziesiątych XX w. Źle wyprofilowane zabezpieczenie połączenia elementów stalowych balustrad z konstrukcją murową wielokrotnie jest głównym transporterem wody w strukturę muru, a co za tym idzie powoduje pogorszenie parametrów wytrzymałościowych i statycznych zaprojektowanych połączeń. W analizie wytrzymałościowej przedstawiono wykorzystanie programów MES oraz role poprawnie przeprowadzonych badań in situ.
Building materials absorb moisture by capillary action when in direct contact with it. The article presents a static analysis of fastening of protective barriers in damaged logs of 5-storey buildings, made in industrialized technology with elements of traditional technology, implemented in the 1980s. Badly profiled protection of the connection of steel railings with the masonry structure, many times it is the main transport of water into the wall structure and thus causes deterioration of the strength and static parameters of the designed connections. The use of MES programs and the roles of correctly conducted In situ tests were presented in the strength analysis.
Źródło:
Przegląd Budowlany; 2022, 93, 7-8; 107--109
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Computation of thin-walled cross-section resistance to local buckling with the use of the critical plate method
Obliczanie nośności przekroju cienkościennego na wyboczenie lokalne metodą "płyty krytycznej"
Autorzy:
Szychowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/962308.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
element cienkościenny
zamocowanie sprężyste
metoda płyty krytycznej
wyboczenie lokalne
zmienność naprężeń wzdłużna
nośność krytyczna
nośność lokalna
nośność obliczeniowa
nośność graniczna
przekrój
thin-walled member
elastic restraint
critical plate method
local buckling
longitudinal stress variation
local resistance
critical resistance
design resistance
ultimate resistance
cross-section
Opis:
Thin-walled bars currently applied in metal construction engineering belong to a group of members, the cross-section resistance of which is affected by the phenomena of local or distortional stability loss. This results from the fact that the cross-section of such a bar consists of slender-plate elements. The study presents the method of calculating the resistance of the cross-section susceptible to local buckling which is based on the loss of stability of the weakest plate (wall). The "Critical Plate" (CP) was identified by comparing critical stress in cross-section component plates under a given stress condition. Then, the CP showing the lowest critical stress was modelled, depending on boundary conditions, as an internal or cantilever element elastically restrained in the restraining plate (RP). Longitudinal stress distribution was accounted for by means of a constant, linear or non-linear (acc. the second degree parabola) function. For the critical buckling stress, as calculated above, the local critical resistance of the cross-section was determined, which sets a limit on the validity of the Vlasov theory. In order to determine the design ultimate resistance of the cross-section, the effective width theory was applied, while taking into consideration the assumptions specified in the study. The application of the Critical Plate Method (CPM) was presented in the examples. Analytical calculation results were compared with selected experimental findings. lt was demonstrated that taking into consideration the CP elastic restraint and longitudinal stress variation results in a more accurate representation of thin-walled element behaviour in the engineering computational model.
Stosowane obecnie w budownictwie metalowym pręty cienkościenne należą do grupy elementów, których nośność przekroju jest warunkowana zjawiskami lokalnej lub dystorsyjnej utraty stateczności. Przekrój poprzeczny klasy 4. jest na ogół złożony ze smukło – płytowych ścianek, które w analizie można modelować wprost jako płyty. W aktualnie obowiązującej normie europejskiej EC3, zjawiska wyboczenia lokalnego i wyboczenia dystorsyjnego, pomimo różnic w długościach wyboczeniowych, uwzględnia się poprzez redukcję nośności przekroju. Stosuje się tutaj metodę szerokości efektywnej (dla wyboczenia lokalnego) oraz grubości zredukowanej (dla wyboczenia dystorsyjnego). Po uwzględnieniu obu zjawisk, otrzymujemy przekrój efektywny służący do obliczania odpowiednich charakterystyk geometrycznych (np. Aeff, Weff). Natomiast ogólną utratę stateczności pręta uwzględnia się za pomocą współczynnika redukcyjnego obliczanego na podstawie smukłości względnej ogólnej utraty stateczności. W związku z tym, poprawne wyznaczenie naprężeń krytycznych wyboczenia lokalnego (w zakresie sprężystym) nabiera szczególnego znaczenia. Stanowi bowiem podstawę do wyznaczenia: 1) szerokości efektywnych poszczególnych płyt (ścianek), 2) naprężeń krytycznych wyboczenia dystorsyjnego (zastępczy przekrój poprzeczny usztywnienia składa się z odpowiednich szerokości efektywnych), oraz 3) ogólnej smukłości względnej elementu. W normach EC3 dotyczących projektowania elementów cienkościennych (o przekroju klasy 4.) przyjęto koncepcję separacji płyt składowych przekroju przy założeniu ich swobodnego podparcia na podłużnych krawędziach łączenia. Ponadto pominięto, często występujący w praktyce, efekt wzdłużnej zmienności naprężeń. Takie założenia upraszczające odbiegają od rzeczywistego zachowania się elementu cienkościennego pod obciążeniem. Liczne badania doświadczalne oraz symulacje numeryczne (np. MES) wykazują, że w rzeczywistych przekrojach cienkościennych występuje wzajemne sprężyste zamocowanie ścianek składowych. Ponadto, w wielu technicznie ważnych przypadkach, występuje wzdłużna zmienność naprężeń. W pracy przedstawiono metodę obliczeń nośności przekroju cienkościennego wrażliwego na wyboczenie lokalne na podstawie utraty stateczności najsłabszej płyty (ścianki). Punktem wyjścia jest założenie, że w przekroju cienkościennym można wyróżnić ściankę „najsłabszą”, która jest sprężyście zamocowana w sąsiedniej ściance usztywniającej (RP). „Płytą krytyczną” (CP) nazwano tę ściankę kształtownika cienkościennego, która w danym stanie naprężenia charakteryzuje się najniższymi naprężeniami krytycznymi. Założono, że połączenie płyty krytycznej z płytą podpierającą jest sztywne, tzn. na podłużnej krawędzi ich łączenia zachowane są warunki ciągłości przemieszczeń (kątów obrotu) i sił (momentów zginających). Dalej ściankę krytyczną modelowano, w zależności od warunków brzegowych, jako sprężyście zamocowaną przeciw obrotowi płytę przęsłową lub wspornikową. Oznacza to, że naprężenia krytyczne dla płyty krytycznej są wyższe niż przy normowym założeniu jej swobodnego podparcia. Stopień sprężystego zamocowania opisano za pomocą wskaźnika utwierdzenia κ, zmieniającego się od 0 dla swobodnego podparcia, do 1 dla pełnego utwierdzenia. Wskaźnik ten oszacowano w oparciu o założoną postać wymuszonego odkształcenia płyty usztywniającej, przy uwzględnieniu wpływu naprężeń ściskających w jej płaszczyźnie. Współczynniki wyboczeniowe (k) dla tak sprężyście zamocowanych i zmiennie obciążonych na długości płyt krytycznych zamieszczono w cyklu artykułów autora [31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42]. W pracach tych uwzględniono wzdłużny rozkład naprężeń wg funkcji stałej, liniowej lub nieliniowej (wg paraboli 2. stopnia). Dla tak obliczonych naprężeń krytycznych wyznaczono „lokalną” nośność krytyczną przekroju, która ogranicza zakres ważności teorii prętów cienkościennych Własowa (o nieodkształcalnym konturze przekroju). Przekroje, w których (dla określonych proporcji geometrycznych) ścianki ściskane ulegają jednoczesnej utracie stateczności (pod danym rozkładem naprężeń), nazwano przekrojami „zerowymi”. W ich przypadku nie występuje wzajemne sprężyste zamocowanie płyt sąsiednich i spełnione jest normowe założenie separacji przegubowo podpartych płyt składowych przekroju pręta.
Źródło:
Archives of Civil Engineering; 2016, 62, 2; 229-264
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-12 z 12

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies