Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "wymiana jonowa" wg kryterium: Temat


Tytuł:
Low waste technology for the removal of nitrates from water
Autorzy:
Trus, Inna
Gomelya, Mukola
Halysh, Vita
Tverdokhlib, Mariia
Makarenko, Iryna
Pylypenko, Tetiana
Chuprinov, Yevhen
Benatov, Daniel
Zaitsev, Hennadii
Powiązania:
https://bibliotekanauki.pl/articles/27311550.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
mineral fertilizers
ion exchange
nitrates
low-waste technologies
anionite
nawozy mineralne
wymiana jonowa
azotany
technologia niskoodpadowa
jonity
Opis:
As a rule, nitrates are present in all natural water bodies. Their increased concentrations are connected with the discharge of insufficiently treated wastewater from industrial and communal enterprises, agricultural and livestock complexes. Recent scientific publications concerning treatment methods for nitrates removal from natural water and wastewater were analyzed in order to create effective and low-waste technology for obtaining high quality water. It has been established that the ion exchange method is quite effective for removing nitrates from water. In the paper, the processes of ion exchange removal of nitrates from water on low-axis anionite in DOWEX Marathon WBA in Сl- form were investigated. During the sorption of nitrates with a concentration of 186, 205, 223 and 2200 mg/dm3, it was established that the full exchangeable dynamic capacity was 1.075, 1.103, and 1.195, 1.698 g-eq/dm3, respectively. To regenerate anionite, solutions of ammonia as well as potassium chloride, ammonium chloride and potassium carbonate were used in this work. The choice of potassium and ammonium compounds is due to the prospect of further use of regeneration solutions for the production of liquid fertilizers.
Źródło:
Archives of Environmental Protection; 2023, 49, 1; 74--78
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of the properties of HAp micropowders after ion exchange process in silver nitrate solution
Autorzy:
Głuszek, Marta
Świrska, Zuzanna
Kaczorowski, Witold
Januszewicz, Bartłomiej
Wrotniak, Maciej
Powiązania:
https://bibliotekanauki.pl/articles/2058388.pdf
Data publikacji:
2021
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
hydroxyapatite
ion exchange
silver nitrate (V)
annealing
XRD
Raman spectroscopy
hydroksyapatyt
wymiana jonowa
spektroskopia
Opis:
Bioceramic materials, such as hydroxyapatite (HAp), are characterized by high biocompatibility in the presence of tissues and body fluids without causing toxic or allergic reactions. Hydroxyapatite, due to its similarity to structures found in bones, is used both in the form of powders, e.g. as additives to bone cements, and implants coatings. However, this material is not characterized by antimicrobial properties, therefore attempts are made to improve its properties by introducing additional elements into the hydroxyapatite structure. Thanks to HAp’s high ion-exchange ability, silver can be introduced into its structure. The calcium ions present in the HAp structure can be easily replaced by silver ions to create a material endowed with high biocompatibility and antibacterial properties. The presented study is based on the analysis of the morphology of the modified powders via scanning electron microscopy (SEM), their chemical composition via X-ray energy dispersive spectroscopy (EDS) and chemical structure via X-ray diffraction (XRD) and Raman spectroscopy. The powders obtained through the ion exchange were mixtures of silver phosphates Ag3PO4 and HAp. The highest silver content was found in the sample modified with a 1M concentration of AgNO3 in the aqueous solution. It was also determined that the annealing of the obtained powders under vacuum at 800°C resulted in the formation of metallic silver and a change in the structure of HAp to β-TCP.
Źródło:
Engineering of Biomaterials; 2021, 24, 161; 15--20
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Promising method of ion exchange separation of anions before reverse osmosis
Obiecująca metoda jonowymiennej separacji anionów przed odwróconą osmozą odsalania wód zmineralizowanych
Autorzy:
Trus, Inna
Gomelya, Mukola
Vorobyova, Viсtoria
Skіba, Margarita
Powiązania:
https://bibliotekanauki.pl/articles/2073807.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ion exchange
nitrates
sulfates
highly mineralized waters
low-waste desalination technology
wymiana jonowa
azotany
siarczany
wody wysokozmineralizowane
niskoodpadowa technologia odsalania
Opis:
A method to improve the quality of purified water, reduce the cost of reagents for the regeneration of resin and create low-waste processes have been developed. This paper presents the results of ion exchange separation of sulfates and nitrates using AV-17-8 anion exchange resin in NO3 form. The efficiency of anion separation on the highly basic anion exchange resin AV-17-8 depends on the magnitude and ratio of their concentrations in water. Separation on the AV-17-8 anion exchange resin has been shown to be effective at concentrations of sulfates up to 800 mg/dm3 and nitrates up to 100 mg/dm3. Conditions for regeneration of 10% NaNO3 anion exchange resin were determined. Reagent precipitation of sulfates from the used regeneration solution in the form of calcium sulfate was carried out. Calcium sulfate precipitate can be used in the manufacturing of building materials. The regeneration solution is suitable for reuse. The developed results will allow to introduce low-waste desalination technology of highly mineralized waters.
Celem pracy było opracowano metody poprawy jakości oczyszczonej wody, obniżenia kosztów odczynników do regeneracji żywicy i stworzenia procesów niskoodpadowych. W pracy przedstawiono wyniki rozdziału jonowymiennego siarczanów i azotanów z użyciem żywicy anionowymiennej AB-17-8 w postaci NO3. Skuteczność separacji anionów na wysoce zasadowej żywicy anionowymiennej AB-17-8 zależy od wielkości i stosunku ich stężeń w wodzie. Wykazano, że rozdział na żywicy anionowymiennej AB-17-8 jest skuteczny przy stężeniach siarczanów do 800 mg/dm3 i azotanów do 100 mg/dm3. Określono warunki regeneracji 10% żywicy anionowymiennej NaNO3. Przeprowadzono odczynnikowe wytrącanie siarczanów z zużytego roztworu regeneracyjnego w postaci siarczanu wapnia. Osad siarczanu wapnia może być wykorzystany do produkcji materiałów budowlanych. Roztwór do regeneracji nadaje się do ponownego użycia. Opracowane wyniki pozwolą na wprowadzenie niskoodpadowej technologii odsalania wód wysokozmineralizowanych.
Źródło:
Archives of Environmental Protection; 2021, 47, 4; 93--97
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ammonia-Ca-K competitive ion-exchange on zeolites in mining wastewater treatment: batch regeneration and column performance
Autorzy:
Chartrand, Zachary G.
Narbaitz, Roberto M.
Sartaj, Majid
Downey, Jason
Powiązania:
https://bibliotekanauki.pl/articles/1839041.pdf
Data publikacji:
2020
Wydawca:
Główny Instytut Górnictwa
Tematy:
ion exchange
ammonia
clinoptilolite
mining wastewater
competitive ion exchange
potassium
wymiana jonowa
amoniak
klinoptylolit
ścieki kopalniane
potas
Opis:
This manuscript addresses the treatment of explosives-impacted mining wastewaters (EIMWW) using ion-exchange to remove elevated levels of ammonia. Repeated batch loading-regeneration cycles were conducted for two commercially available zeolite media used in the treatment of ammonia-laden EIMWW to establish the effects of competing ions and regeneration solution composition. The Northern Ontario EIMWW tested contained 3.87 meq/L total ammonia (TA) as well as 2.85 mg/L K+ and 3.9 meq/L Ca2+. The media studied were a natural clinoptilolite and a modified clinoptilolite (SIR-600). Five regenerant solutions with different NaCl and KCl concentrations were evaluated using batch tests. The presence of potassium in the regenerant was found to hinder the TA exchange capacity of both zeolites. The SIR-600 and the natural clinoptilolite used in conjunction with the 10% NaCl solution featured the best TA exchange capacities, 0.46 ± 0.02 meq TA/g and 0.36 ± 0.05 meq TA/g, respectively. The batch tests showed that both media had a slight preference for K+ over TA. The continuous flow column tests performed using SIR-600 media greatly accentuated the selectivity of K+ over TA. In reaching the same 0.55 meq TA/L breakthrough level, the same modified zeolite column was able to treat five times more volume of a synthetic TA solution than EIMWW.
Źródło:
Journal of Sustainable Mining; 2020, 19, 2; 58-71
2300-1364
2300-3960
Pojawia się w:
Journal of Sustainable Mining
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cooper removal and recovery from aqueous solutions by using selected synthetic ion exchange resins (part I)
Usuwanie i odzysk miedzi z roztworów wodnych przy użyciu wybranych syntetycznych żywic jonowymiennych (część I)
Autorzy:
Orlof-Naturalna, Monika
Bożęcka, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/1841489.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Przeróbki Kopalin
Tematy:
copper ions
ion exchange
ion exchanger resins
microstructural research
jony miedzi
wymiana jonowa
jonity
badania mikrostrukturalne
Opis:
The paper presents results of research on removal of Cu2+ ions from aqueous solutions by ion exchange method in concentration range of 10–1000 mg/L. For this purpose, following Purolite synthetic ion exchange resins were used: S 910, S 930, S 940, S 950 and C 160. The obtained results were interpreted based on the degree of solution purification and microstructural investigations. The regeneration possibility of used ion exchangers with a 10% hydrochloric acid solution was also investigated. Based on obtained results, it was determined that studied ion exchangers efficiently removed copper(II) ions from aqueous solutions, especially in low concentrations. Microstructural investigation made for tested materials after the sorption process clearly indicate that Cu2+ ions removal process was in accordance with ion exchange mechanism, which was confirmed by recorded SEM images. All ion exchangers except S 910, purified solutions from Cu2+ ions with an efficiency greater than 90% up to a concentration of 100 mg/L. In case of S 930 and S 940 ion exchangers, their efficiency was close to 100%. For higher concentrations, efficiency of studied ion exchangers decreased significantly. The lowest decrease in degree of copper(II) S 910 chelating resin with amidoxime groups was the least efficient. All studied ion exchangers can be regenerated with a 10% hydrochloric acid solution. The efficiency of this process varies from 53.1% to 80.5% depending on the used resins.
W pracy przedstawiono wyniki badań dotyczące usuwania jonów Cu2+ z roztworów wodnych metodą wymiany jonowej w zakresie stężeń 10–1000 mg/L. W tym celu zastosowano żywice jonowymienne firmy Purolite: S 910, S 930, S 940, S 950 i C 160. Otrzymane wyniki zinterpretowano w oparciu o stopień oczyszczenia roztworu i badania mikrostrukturalne. Zbadano również możliwość rege¬neracji użytych jonitów za pomocą 10% roztworu kwasu solnego. Na podstawie otrzymanych wyników stwierdzono, że badane jonity skutecznie usuwały jony miedzi(II) z roztworów wodnych, szcze¬gólnie w niskich stężeniach. Badania mikrostrukturalne wykonane dla badanych materiałów po procesie sorpcji wyraźnie wskazują, że proces usuwania jonów Cu2+ zachodził zgodnie z mechanizmem wymiany jonowej, co potwierdzają zarejestrowane obrazy SEM. Na powierzchni badanych jonitów nie zaobserwowano mikrostrąceń. Wszystkie wymieniacze jonowe z wyjątkiem S 910 oczyszczały roztwory z jonów Cu2+ z wydajnością większą niż 90% do stężenia 100 mg/L. W przypadku jonitów S 930 i S 940 ich skuteczność było bliska 100%. W przypadku większych stężeń wydajność badanych jonitów znacząco malała. Najmniejszy spadek stopnia wydzielenia jonów miedzi(II) zaobserwowano dla kationitu C 160 zawierają¬cego grupy sulfonowe. Najmniej skuteczny okazał się jonit chelatujący S 910 z grupami amidoksymowymi. Wszystkie badane jonity można regenerować za pomocą 10% roztworu kwasu solnego. Wydajność tego procesu waha się od 53,1% do 80,5% w zależności od użytej żywicy jonowymiennej.
Źródło:
Inżynieria Mineralna; 2020, 2, 2; 7-14
1640-4920
Pojawia się w:
Inżynieria Mineralna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The removal of sulphate ions from model solutions and their influence on ion exchange resins
Autorzy:
Demcak, Stefan
Balintova, Magdalena
Holub, Marian
Powiązania:
https://bibliotekanauki.pl/articles/96354.pdf
Data publikacji:
2020
Wydawca:
Fundacja Ekonomistów Środowiska i Zasobów Naturalnych
Tematy:
ion exchange
resin
sulphate
water treatment
wymiana jonowa
żywica
siarczan
uzdatnianie wody
Opis:
There is a growing tendency for industries around the globe to diminish the contents of pollutants in industrial wastewaters to an acceptable level. Conventional methods are unfavourable and economically unacceptable, especially for large volumes of wastewaters with a high content of undesirable compounds. In contrast, ion–exchange is a very powerful technology capable of removing contamination from water. This paper analyses a study of ion exchange in Amberlite MB20 and Purolite MB400 resins after sulphate removal from a model solution. For the characterisation of ion exchange in resins, infrared spectroscopy was used. The IR spectra of both ion exchange resins show a similar composition after adsorption. Experiments that are due to this same used matrix in producing. The efficiency of sulphate ion removal and pH changes were also measured. Amberlite MB20 has proven to be a suitable ion exchange resin due to its high effi ciency (about 86%) for the removal of sulphates from solutions with initial concentrations of 100 and 500 mg.L-1, respectively.
Źródło:
Ekonomia i Środowisko; 2020, 2; 59-70
0867-8898
Pojawia się w:
Ekonomia i Środowisko
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mathematical modeling singularly perturbed processes of water softening on sodium-cationite filters
Modelowanie matematyczne syngularnego zaburzonego procesu zmiękczania wody w filtrach sodowo-kationowych
Autorzy:
Safonyk, Andrii
Prysiazhniuk, Ihor
Prysiazhniuk, Olena
Naumchuk, Oleksandr
Powiązania:
https://bibliotekanauki.pl/articles/952722.pdf
Data publikacji:
2019
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
mathematical modelling
ion exchange
adsorption
modelowanie matematyczne
wymiana jonowa
absorpcja
Opis:
Mathematical model of the process of water softening using ion exchange pre-treatment of waters to desalination, with a view to removal of scale forming components, such as calcium and magnesium, are formed in the paper. In this process, no additional chemicals, except for brines formed during desalination, are required for regeneration of ion-exchanger in operation cycles. An asymptotic approximation of a solution of a corresponding model problem is constructed. Theoretical description and modelling assumptions included the set of differential equations of mass balance, initial, boundary and operational conditions. The paper deals with the development of a computer model for description and prediction of the performance of ion exchange columns.
W pracy opracowano matematyczny model procesu zmiękczania wody przy użyciu wstępnej obróbki wody poprzez wymianę jonową do odsalania w celu usunięcia składników tworzących kamień, takich jak wapń i magnez. W procesie tym dla regeneracji wymiennika jonowego w cyklach roboczych nie trzeba wykorzystywać dodatkowych chemicznych czynników za wyjątkiem solanek, które powstają podczas odsalania. Opracowano asymptotyczne przybliżenie odpowiedniego rozwiązania z modelem. Opis teoretyczny i założenia modelu obejmują szereg równań różniczkowych bilansu masy, warunków początkowych, granicznych i eksploatacyjnych. Rozpatrzono opracowanie modelu komputerowego dla opisu i prognozowania działania kolumn wymiany jonowej.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2019, 9, 1; 37-40
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Removal of chromium(VI) from wastewater through ion exchange. Kinetic and scale up studies
Autorzy:
Ahmad, Syed Waqas
Zafar, Muhammad Shahzad
Ahmad, Sajjad
Zia-Ul-Haq, M.
Ashraf, Muhammad
Rabbani, Javed
Ullah, Sami
Powiązania:
https://bibliotekanauki.pl/articles/208034.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
ion exchange
industrial wastewater
anion resin
heavy metals
cadmium
wymiana jonowa
ścieki przemysłowe
żywica anionowa
metale ciężkie
kadm
Opis:
Chromium(VI) ions were removed from industrial wastewater. In this regard, a rig was fabricated carrying alkaline anion resin. Various experiments were carried out by varying pH, temperature and volumetric flow rate of solution by employing a rig to study the kinetics of the ion exchange process. The rate constant (k) and maximum solid phase concentration of exchanged solute (q0) were calculated using the Thomson equation to scale up the purification process of industrial runoff of chromium(VI) from the tanning, photography and ceramic industry. Experimental optimization revealed that developed setup will remove chromium(VI) to a level of 5 mg/dm3 from 300 mg/dm3 in 40 000 dm3 of wastewater. To achieve the best results for the flow rate of 10 000 3 3/day, 12.03 kg of anionic resin were recommended by fixing the pH of the setup at 7.4 while maintaining the treatment temperature at 20 °C.
Źródło:
Environment Protection Engineering; 2019, 45, 1; 17-29
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Synthesis of zeolite A using the waste of iron mine tailings dam and its application for industrial effluent treatment
Autorzy:
Izidoro, Juliana de Carvalho
Kim, Michelle Caroline
Bellelli, Valentina Ferraraccio
Pane, Mara Cristina
Botelho Junior, Amilton Barbosa
Espinosa, Denise Crocce Romano
Tenório, Jorge Alberto Soares
Powiązania:
https://bibliotekanauki.pl/articles/1839010.pdf
Data publikacji:
2019
Wydawca:
Główny Instytut Górnictwa
Tematy:
Fundao dam
Brumadinho
mining tailings
Mariana
ion exchange
zapora Fundao
odpady wydobywcze
wymiana jonowa
Opis:
In November 2015, a dam from iron mining collapsed, which is considered as the largest environmental accident in Brazil. Over than 50 million m³ were released reaching the Doce River and killed 20 people in Mariana. The literature review shows that the mining tailings can be used as raw material to the synthesis of zeolites, which can be used for the wastewater treatment. The aim of this work was the synthesis of zeolites from the Samarco tailings and its application for the treatment of electroplating effluent. The residue was characterized which identified high-iron content for the synthesis of zeolites. The residue was mixed with NaOH (1:1) and the reaction temperature was evaluated from 350 °C to 650 °C. Then, the material was mixed with aluminum source and the effect of time was evaluated. The zeolite was applied to the wastewater treatment from electroplating industry. Results showed that the synthesis of zeolite A was carried out with a fusion step at 450 °C for 1 h using RAS: NaOH ratio 1:1, and further hydrothermal treatment at 100 °C during 4 h. The zinc removal from the wastewater was up to 98% using 50 mL of the solution, 2.5 g zeolite A, 60min and pH 6.4. The main metals presented in the solution were adsorbed up to 90% by the zeolite synthesized. Zinc adsorption by the zeolite fitted better on Langmuir isotherm. The zeolite was used four times in a row and zinc removal declined 98-68%.
Źródło:
Journal of Sustainable Mining; 2019, 18, 4; 277-286
2300-1364
2300-3960
Pojawia się w:
Journal of Sustainable Mining
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Proposal and Testing of Multi-Step Process for Acid Mine Drainage Treatment
Wieloetapowy proces oczyszczania kwaśnych wód z drenażu kopalni – propozycja i weryfikacja
Autorzy:
Holub, M.
Balintova, M.
Pavlikova, P.
Powiązania:
https://bibliotekanauki.pl/articles/318689.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Przeróbki Kopalin
Tematy:
sorpcja
strącanie
wymiana jonowa
metale ciężkie
siarczany
Kwaśny Drenaż Kopalniany (AMD)
sorption
precipitation
ion-exchange
heavy metals
sulphates
acid mine drainage
Opis:
The mining represents one the most common human activities that fundamentally impact not only the country itself but also have adverse effects on the fauna, flora and human beings. The negative impacts also include acid mine drainage which is formed by the dissolution of products resulting from the oxidation (chemically and microbiologically mediated) of sulphide minerals, mainly pyrite or iron disulphide. According to stringent European Union effluent discharge regulations it is necessary to look into innovative technologies to remove considerable amount of effluent rather than discharging into surface water. Resulting from previous partial achievements, the article is focused on the combination of chemical precipitation, ion exchange and biosorption techniques for the acid mine drainage treatment. Concentrations of four different metal cations (copper, iron, manganese, aluminium) and sulphates were observed. First stage of treatment included chemical precipitation by combination of oxidation using 31% hydrogen peroxide and subsequent precipitation with 0.1 M sodium hydroxide. After the first stage, the ion exchange using two different exchangers (PUROLITE MB400 resin and AMBERLITE MB20 resin) took place. The last stage of the experiments was focused of the biosorption study. Low – cost sorbents included in this case natural non – modified peat “PEATSORB” and hemp shives in modified state. Overall, the best results were observed after combination of MB20 resin in the second stage and subsequent using of modified hemp shives in the third stage of the treatment.
Górnictwo jest jedną z działalności człowieka, która ma zasadniczy wpływ na środowisko - faunę, florę i ludzi. Negatywne oddziaływania obejmują także kwaśne wody z drenażu kopalnianego, który powstaje w wyniku rozpuszczania produktów powstałych w wyniku utleniania (chemicznego i mikrobiologicznego) minerałów siarczkowych, głównie pirytu lub dwusiarczku żelaza. Zgodnie z rygorystycznymi przepisami Unii Europejskiej dotyczącymi zrzutu ścieków konieczne jest przyjrzenie się innowacyjnym technologiom, które pozwalają na usunięcie znacznych ilości ścieków, aby uniknąć odprowadzania ich do wód powierzchniowych. W artykule Autorzy skoncentrowali się na kombinacji technik wytrącania chemicznego, wymiany jonowej i biosorpcji. Badano stężenia czterech różnych kationów metali (miedzi, żelaza, manganu, glinu) i siarczanów. Pierwszy etap ługowania obejmował wytrącanie chemiczne przez połączenie utleniania przy użyciu 31% nadtlenku wodoru i następnie wytrącanie 0,1 M wodorotlenkiem sodu. Po pierwszym etapie prowadzono wymianę jonową za pomocą dwóch różnych wymienników (żywica PUROLITE MB400 i żywica AMBERLITE MB20). Ostatni etap eksperymentów skoncentrowano na badaniu biosorpcji. Niskokosztowe sorbenty obejmują w tym przypadku naturalne torfy niezmodyfikowane „PEATSORB” i zmodyfikowane łupiny konopi. Ogólnie najlepsze wyniki zaobserwowano po połączeniu żywicy MB20 w drugim etapie i zastosowaniu zmodyfikowanych łupin konopi w trzecim etapie.
Źródło:
Inżynieria Mineralna; 2018, R. 20, nr 2, 2; 201-206
1640-4920
Pojawia się w:
Inżynieria Mineralna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research of Co2+ ions removal from water solution by using ion exchangers
Badania nad usuwaniem jonów Co2+ z roztworów wodnych przy użyciu wymieniaczy jonowych
Autorzy:
Bożęcka, A.
Sanak-Rydlewska, S.
Powiązania:
https://bibliotekanauki.pl/articles/216689.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
jonit
wymiana jonowa
ścieki
jony kobaltu
ion exchange resin
ion exchange
wastewater
cobalt ions
Opis:
At present, industrial development is increasing pollution of soils, air and natural waters. These pollutants have a negative effect on the health and life of living organisms. Metals which interfere with the natural biological balance and inhibit self-cleaning processes in water bodies have particularly toxic effects. Cobalt, which gets into the environment from industrial sewage from electrochemical plants and the metallurgical industry, also belong to this group. This is also relatively rare and precious element, so it is important to look for additional sources of its recovery. Chemical and physicochemical methods such as: precipitation, extraction, membrane processes – nanofiltration, reverse osmosis, sorption and ion exchange are used to recover cobalt. The choice of method depends on: the kind and composition of wastewaters as well as on form and concentration of the pollutants. Ion exchange resins produced by Purolite which were used to remove cobalt ions from solutions with concentrations corresponding to its contents in galvanic wastewater was the subject of the study. It has been shown that the C 160 ion exchange resin has the best the sorption properties for Co2+ ions (54.7 mg/g). In case of this ion exchange resin, after sorption process carried out in one 50 minute cycle, cobalt concentration decreased from about 30 g/L to about 9 g/L. The values of the sorption capacity do not depend on the method of introducing the solution into an ion exchange column (pouring or dropping). Each of the tested ion exchange resins is characterized by a high degree of cobalt concentration after regeneration using mineral acids, which can be advantageous in selecting the recovery method for this metal.
Współcześnie rozwój przemysłu przyczynia się do wzrostu zanieczyszczenia gleb, powietrza i wód naturalnych. Zanieczyszczenia te negatywnie wpływają na zdrowie i życie organizmów żywych. Toksyczne działanie wykazują zwłaszcza metale, które zakłócają naturalną równowagę biologiczną oraz hamują procesy samooczyszczania w zbiornikach wodnych. W tej grupie jest również kobalt, który dostaje się do środowiska naturalnego ze ścieków przemysłowych pochodzących z zakładów elektrochemicznych oraz z przemysłu metalurgicznego. Jest to również stosunkowo rzadki i cenny pierwiastek, dlatego ważne jest poszukiwanie dodatkowych źródeł jego odzysku. Do pozyskiwania kobaltu stosuje się metody chemiczne i fizykochemiczne, takie jak: strącanie; ekstrakcja; procesy membranowe – nanofiltracja, odwrócona osmoza, sorpcja i wymiana jonowa. Wybór metody zależy od rodzaju i składu ścieków oraz postaci i stężenia usuwanych form zanieczyszczeń. Przedmiotem badań były jonity firmy Purolite, które zastosowano do usuwania jonów Co2+ z roztworów o stężeniach odpowiadających zawartościom tego metalu w ściekach galwanicznych. Wykazano, że najlepsze właściwości sorpcyjne w stosunku do badanych jonów ma kationit C 160 (54,7 mg/g). W przypadku tego jonitu po jednym, 50-minutowym cyklu, stężenie kobaltu obniża się z około 30 do około 9 g/dm3. Wartości pojemności sorpcyjnej nie zależą od sposobu wprowadzania roztworu do kolumny jonitowej (wlanie lub wkraplanie). Każdy z badanych jonitów charakteryzuje się wysokim stopniem koncentrowania kobaltu w wyniku regeneracji przy użyciu kwasów mineralnych, co może być korzystne przy wyborze metody odzysku tego metalu.
Źródło:
Gospodarka Surowcami Mineralnymi; 2018, 34, 3; 85-98
0860-0953
Pojawia się w:
Gospodarka Surowcami Mineralnymi
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wydzielenie jonów cynku(II) z roztworów siarczanowych i chlorkowych za pomocą żywicy Lewatit MonoPlus SP112
Removal of zinc(II) ions from sulphate and chloride solutions using Lewatit MonoPlus SP112 ion-exchange resin
Autorzy:
Chrapek, M.
Gęga, J.
Powiązania:
https://bibliotekanauki.pl/articles/410314.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet Humanistyczno-Przyrodniczy im. Jana Długosza w Częstochowie. Wydawnictwo Uczelniane
Tematy:
wymiana jonowa
cynk
kinetyka
izotermy adsorpcji
ion exchange
zinc
kinetics
adsorption isotherms
Opis:
W prezentowanej pracy przedstawiono wyniki badań wpływu parametrów operacyjnych na szybkość i równowagę wymiany jonów Zn(II) zachodzącej na kwaśnej żywicy Lewatit MonoPlus SP 112. Badania prowadzono z roztworów siarczanowych(VI) i chlorkowych w zakresie stężenia początkowego Zn 2+ od 0,0001 do 0,1 mol/dm3 i pH zmienianego w zakresie od 0 do 6. Stwierdzono, że możliwa jest sorpcja jonów cynku na zastosowanej żywicy, a kinetyka procesu może być opisana za pomocą modelu reakcji pseudo II rzędu. Ponadto zaobserwowano, że ze wzrostem stężenia początkowego Zn2+ wzrasta ilość zaadsorbowanych jonów cynku.
The paper presents the results of research on the influence of operating parameters on kinetics and equilibria of Zn(II) ion exchange on the acidic Lewatit MonoPlus SP 112 resin. The tests were carried out from sulphate(VI) and chloride solutions at the initial Zn2+ concentration ranged from 0.0001 to 0.1 mol/dm3 and pH ranged from 0 to 6. It was found that the sorption of zinc ions on the resin used is possible, and the kinetics of the process can be described by means of a pseudo secondary order equation. In addition, it was observed that the amount of adsorbed zinc ions increased with increasing of Zn2+ initial concentration.
Źródło:
Chemistry, Environment, Biotechnology; 2018, 21; 46-51
2083-7097
Pojawia się w:
Chemistry, Environment, Biotechnology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania spektralne (FTIR, UV-Vis) montmorylonitu modyfikowanego ultradźwiękami i kationami potasu
Spectral study (FTIR, UV-Vis) of montmorillonite modified by ultrasound and potassium cations
Autorzy:
Grabowska, B.
Kurleto-Kozioł, Ż.
Powiązania:
https://bibliotekanauki.pl/articles/391444.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Odlewnictwa
Tematy:
montmorylonit
modyfikacja montmorylonitu
wymiana jonowa
CEC
pole ultradźwięków
montmorillonite
montmorillonite modification
ion exchange
ultrasound field
Opis:
W pracy przedstawiono wyniki badań spektralnych (FTIR, UV-Vis) przeprowadzonych dla próbek nieaktywowanego bentonitu (wapniowego) posiadającego w swym składzie główny składnik mineralny montmorylonit (MMT). MMT, jako składnik bentonitu zawierający jony wapnia (Ca-MMT), poddano modyfikacji na drodze fizycznej i chemicznej. Proces aktywacji fizycznej zainicjowano działaniem pola ultradźwięków (40 kHz). Modyfikację chemiczną Ca-MMT, poprzez wymianę jonową kationów wapnia na kationy potasu, przeprowadzono z udziałem modyfikatora w postaci węglanu potasu, przy czasie aktywacji równym 1 h. W celu określenia efektywności przeprowadzonej modyfikacji dla zmodyfikowanych fizycznie i chemicznie próbek montmorylonitu (K-MMT) w bentonicie przeprowadzono cykl badań analitycznych, w tym strukturalnych (FTIR) oraz spektrofotometrycznych (UV-Vis). Stwierdzono, że rodzaj i sposób prowadzenia modyfikacji, w tym zmiana czasu działania czynnika fizycznego na nieaktywowany bentonit, wpływa na zdolność do wymiany jonowej montmorylonitu (CEC). Zarówno zmodyfikowany fizycznie (ultradźwięki), jak i chemicznie (kationy potasu) MMT w bentonicie wapniowym wykazuje CEC na nieco niższym poziomie od CEC wyznaczonego dla stosowanego w technologii mas formierskich bentonitu sodowego. Zmodyfikowany MMT może więc stanowić alternatywny materiał wiążący do zastosowania w masach klasycznych.
This paper presented the spectral study (FTIR, UV-Vis) for samples of non-activated bentonite (calcium) which has in its composition a main mineral resource, montmorillonite (MMT). MMT, as a component which contains calcium ions (Ca-MMT, was modified physically and chemically. The process of physical activations was initiated by an ultrasound field (40 kHz) with the use of a modificator in the form of potassium carbonate with an activation time of 1 h. To measure the efficiency of the modification for modified physically and chemically samples of montmorillonite (K-MMT) in bentonite there was performed a cycle of test including structural (FITR) and spectrofotometric (UV-Vis) analysis. It was stated that the type and method of making the modification including change of time in which physical factors are influencing the non-activated bentonite influences on the change of ion exchange of montmorillonite (CEC). Both modified physically (ultrasound) and chemically (potassium cations) MMT in calcium bentonite exhibits CEC on a slightly lower level than CEC used in the moulding sand technology of sodium bentonite. Modified MMT can be therefore used as an alternative material for green sand.
Źródło:
Prace Instytutu Odlewnictwa; 2017, 57, 2; 125-136
1899-2439
Pojawia się w:
Prace Instytutu Odlewnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elimination of selected anions and cations from water by means of the Donnan dialysis
Autorzy:
Wiśniewski, J. A.
Kabsch-Korbutowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/207743.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
wymiana jonowa
właściwości membrany
stężenie soli
ion exchange
Donnan dialysis
membrane properties
salt concentration
Opis:
The usefulness of the Donnan dialysis has been assessed for the elimination of harmful (bromide, bromate and nitrate) or troublesome (calcium and magnesium) ions from water. The rate and efficiency of ion exchange were examined. For anion removal Selemion AM V or Neosepta ACS membranes were used while for cation removal - Neosepta CMX or Selemion CMV ones. The influence of membrane properties and salt concentration in the receiver was investigated.
Źródło:
Environment Protection Engineering; 2017, 43, 3; 189-205
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Potential of pumice modified with iron(III) for copper removal from aqueous solutions
Autorzy:
Guler, U. A.
Cebeci, M. S.
Powiązania:
https://bibliotekanauki.pl/articles/207939.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
adsorption capacities
copper concentration
ion exchange
iron oxides
water treatment
zdolność adsorpcji
stężenie miedzi
wymiana jonowa
tlenki żelaza
uzdatnianie wody
Opis:
Iron-modified pumice (Fe-P) was prepared by the ion-exchange method using natural pumice from Kayseri, Turkey at room temperature without calcination. SEM, FTIR, XRD, and S-BET measurement were used to investigate the copper removal mechanism. The results show that the SBET of the pumice increased from 11.88 m2/g to 21.01 m2/g after iron modification. The effects of pH, contact time, initial copper concentration, temperature, and various cations (Na+, K+, Ca2+, Mg2+ and Al3+) at various pH were investigated in batch experiments. More than 92% of Cu(II) was removed after 180 min. Langmuir, Freundlich, Dubinin-Radushkevich and Temkin isotherm models were applied to the equilibrium data at 298, 308 and 318 K. The maximum adsorption capacity at 298, 308 and 318 K was found to be 21.52, 19.48, and 19.67 mg/g, respectively. The kinetics of copper on Fe-P was best described by the pseudo-second order kinetic model. The negative values of free energy change and enthalpy change indicated that the adsorption process was feasible, spontaneous and exothermic.
Źródło:
Environment Protection Engineering; 2017, 43, 3; 165-180
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies