Tytuł:
Improving the operation of a surface water intake with exceeded redundant capacity using reliability analysis and life cycle costing
Autorzy:
Zimoch, I.
Szymik-Gralewska, J
Powiązania:
https://bibliotekanauki.pl/articles/207949.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
decision support systems
life cycle
water intakes
reliability indicators
System Wspomagania Decyzji
ocena cyklu życia
wskaźnik niezawodności
ujęcie wody
Opis:
Integrated procedures of analysis have been presented combining both reliability and economical aspects of operation of a water supply system (WSS). The method presented is a practical application of the reliability analysis and life-cycle costing which is a part of a decision support system (DSS) for WSS. It focuses on undisturbed operation of systems with exceeded redundant capacity minding system's reliable and lower possible operational costs. The proposed analytical approach is shown on the example of the surface water intake which is the first subsystem of WSS influencing operation of a whole system. As a part of the study, reliability and economic assessments of various variants of future operation of water intake have been carried out as a basis for choosing most advantageous solution. The authors indicate how exceeded redundant capacity affects applied maintenance method of the system. All calculations of the reliability indicators are based on operating data contained in exploitation logs (2001-2012). The costs have been estimated based on the obtained financial documentation.
Źródło:
Environment Protection Engineering; 2016, 42, 2; 41-53
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Niezawodnościowa interpretacja wyników monitoringu jakości wody w sieci wodociągowej
Monitoring of the quality of the water in water-pipe networks: Reliability interpretation of the results
Autorzy:
Zimoch, I.
Powiązania:
https://bibliotekanauki.pl/articles/236538.pdf
Data publikacji:
2009
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
jakość wody
monitoring
system dystrybucji wody
niezawodność
wskaźnik gotowości
wskaźnik intensywności
water quality
water distribution system
reliability
availability index
efficiency index
Opis:
Obecny poziom technik komputerowych pozwala na ich skuteczne wykorzystanie w procesie monitorowania działania systemów wodociągowych oraz do analizy ich krytycznych elementów, w aspekcie jakości dostarczanej wody. W pracy przedstawiono analizę niezawodnościową funkcjonowania monitoringu jakości wody, na przykładzie systemu zaopatrzenia Wrocławia w wodę. Przeprowadzona analiza obejmowała wyznaczenie intensywności występowania jakości wody niezgodnej ze standardami, średniego czasu trwania nieodpowiedniej i odpowiedniej jakości wody w sieci wodociągowej, prawdopodobieństwa dostarczenia wody o wymaganej jakości, a także wartości wskaźników gotowości i niezawodności dostawy wody o wymaganej jakości. Ponadto omówiono algorytm i program komputerowy Jakość Wody, stanowiący podstawowe narzędzie analityczne w badaniu niezawodności funkcjonowania monitoringu jakości wody w systemach wodociągowych. Wykazano, że informacje uzyskane w procesie monitoringu dają możliwość przeprowadzenia kompleksowej oceny poziomu świadczonych usług wodociągowych w funkcji ryzyka przekroczenia wartości dopuszczalnych stężeń wskaźników jakości wody.
The available state-of-the-art computer techniques offer the possibility of monitoring how the water supply system functions, as well as analyzing the critical elements of the system, such as the quality of the water being supplied. This paper contains a reliability analysis of the functioning of the water quality monitoring process in a large water supply system (using the municipal water supply system of the city of Wroclaw as an example). Assessments were carried out for the following parameters: rate of occurrence of water quality below standard; average duration of the occurrence of up-to-standard and below-standard water quality in the water-pipe network; probability of supplying water of required quality; availability index and efficiency index of supplying water of required quality. The paper also includes the relevant algorithm and computer program ('Jakosc Wody' - Water Quality), the basic analytical tools for examining the reliability of the functioning of water quality monitoring in the water distribution system. It has been demonstrated that the information obtained from monitoring enables a complex assessment of the quality of the services provided by the waterworks, as it incorporates the risk that the admissible values of the water quality parameters can be exceeded. słowa kluczowe polskie: Jakość wody, monitoring, system dystrybucji wody, niezawodność, ryzyko, wskaźnik gotowości, wskaźnik intensywności.
Źródło:
Ochrona Środowiska; 2009, 31, 4; 51-56
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Możliwości zastosowania wskaźnika chlorkowo-bromkowego w identyfikacji zanieczyszczenia wód płynami po szczelinowaniu hydraulicznym
Possibilities of using chloride-bromide ratio in the identification of fracturing fluids contamination water
Autorzy:
Winid, B.
Powiązania:
https://bibliotekanauki.pl/articles/299117.pdf
Data publikacji:
2012
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
wskaźnik chlorkowo-bromkowy
zanieczyszczenie wód
wody zasolone
chloride-bromide ratio
contaminated water
saline water
Opis:
Jednym z problemów rozważanych w dyskusji na temat eksploatacji gazu łupkowego jest wpływ procesu szczelinowania hydraulicznego na stan środowiska wodnego. Wobec braku doświadczeń w tej dziedzinie musimy odwoływać się do prac i propozycji krajów, które już te działania podejmują. W pracy przeanalizowano możliwość zastosowania wskaźnika chlorkowo-bromkowego (równowagowego ilorazu zawartości jonów chlorkowych i bromkowych) do oceny stanu środowiska w aspekcie zanieczyszczenia płynami po szczelinowaniu hydraulicznym. Zwrócono uwagę na możliwości innych ognisk zanieczyszczeń, które mogą skutkować podobnym zakresem wartości tego wskaźnika, a także na niewielką ilość danych dotyczących wartości tego wskaźnika w wodach aktywnej strefy wymiany w warunkach Polski.
The impact of the hydraulic fracturing process on the water environment is one of the problems considered in the discussion on the exploiation of shale gas. In the absence of experience in this field we refer to the work and proposals for countries that already take these actions. The paper analyzes the possibility of using chloride-bromide ratio (the equilibrium ratio of chloride and bromide ion content) to assess the state of the environment in terms of contamination by hydraulic fracturing fluids. Attention was drawn to the possibility of other pollution sources, which may result in a similar range of values of this index. As well a small amount of data on the value of this ratio in the waters of an active exchange zone in the area of Poland.
Źródło:
AGH Drilling, Oil, Gas; 2012, 29, 1; 313-321
2299-4157
2300-7052
Pojawia się w:
AGH Drilling, Oil, Gas
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka hydrogeochemiczna wód leczniczych Rabki-Zdroju
The hydrogeochemical characteristics of therapeutic waters in Rabka Spa
Autorzy:
Wiktorowicz, B.
Karwacka, K.
Powiązania:
https://bibliotekanauki.pl/articles/2062901.pdf
Data publikacji:
2009
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
wody lecznicze
wskaźnik nasycenia
równowaga hydrogeochemiczna
therapeutic waters
saturation index
hydrogeochemical equilibrium
Opis:
Wody lecznicze Rabki-Zdroju są znane i cenione już od dawna. Są to wody mineralne, głównie typu chlorkowo-sodowego, jodkowe oraz zawierające brom. Geneza wód chlorkowych występujących w obrębie utworów fliszu Karpat jest skomplikowana i ciągle dyskusyjna. Niniejszy artykuł przedstawia wstępne wyniki obliczeń równowagi hydrogeochemicznej wód leczniczych Rabki-Zdroju. Do realizacji pracy wykorzystano modelowanie hydrogeochemiczne, które przeprowadzono przy użyciu programu komputerowy WATEQ4F. Stwierdzono, że minerałami decydującymi o równowadze hydrogeochemicznej wód leczniczych Rabki-Zdroju są chalcedon, grupa skaleni i illit.
In Rabka Spa, within the Magura nappe, occurrences of springs with therapeutic waters have been known from historical records. All drillings recorded Cl-Na type waters with iodine and bromine. The origin of chloride waters in the Polish Flysch Carpathians is complicated and discussed. This paper contains the preliminary results of research on hydrogeochemical equilibrium in therapeutic waters in Rabka Spa. The modelling study was carried out with the use of WATEQ4F software. Minerals regulating the hydrogeochemical equilibrium in therapeutic waters in Rabka Spa are principally chalcedony, feldspar group and illite.
Źródło:
Biuletyn Państwowego Instytutu Geologicznego; 2009, 436, z. 9/2; 529-534
0867-6143
Pojawia się w:
Biuletyn Państwowego Instytutu Geologicznego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza hydrologiczno-środowiskowa lokalizacji małej elektrowni wodnej na rzece Budkowiczanka w miejscowości Krzywa Góra
Hydrological and environmental analysis of the location of a small hydropower plant on the Budkowiczanka River in the village of Krzywa Góra
Autorzy:
Wiatkowski, M.
Gruss, Ł.
Tomczyk, P.
Powiązania:
https://bibliotekanauki.pl/articles/399920.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
małe elektrownie wodne
odnawialne źródła energii
moc teoretyczna elektrowni
hydrologia
wskaźnik względnego opadu
odpływ
jakość wody
rzeka Budkowiczanka
small hydro power
renewable energy sources
mechanical power
hydrology
relative precipitation index
outflow
water quality
Budkowiczanka River
Opis:
W niniejszym artykule Autorzy przedstawili analizę warunków hydrologiczno-środowiskowych w aspekcie lokalizacji małej elektrowni wodnej na rzece Budkowiczance. Zlewnia rzeki Budkowiczanki wynosi A=232 km2 i znajduje się w południowo–zachodniej Polsce w województwie opolskim. Długość rzeki Budkowiczanki wynosi ok. 60 km. Autorzy zaproponowali lokalizację małej elektrowni wodnej na jazie w km 20,142 jej biegu w miejscowości Okoły-Kupi Las w gminie Murów. Badany przekrój należy zaliczyć do jednolitej części wód powierzchniowych „Budkowiczanka od Wiszni do Stobrawy”. Planowany na cele małej energetyki wodnej jaz zlokalizowany jest w odległości około 1,7 km powyżej wodowskazu Krzywa Góra. Przeanalizowano warunki hydrologiczne w rzece Budkowiczance dla profilu wodowskazowego Krzywa Góra. Na potrzeby hydrotechniki, dla rzeki Budkowiczanka, w przekroju wodowskazowym Krzywa Góra, wyznaczono stany i przepływy charakterystyczne obejmujące okres 1981-2015. Dla poszczególnych rocznych sum opadów z wielolecia 1981-2015, dla stacji Opole zlokalizowanej w pobliżu zlewni rzeki Budkowiczanki wyznaczono lata bardzo suche i suche. Dla tych lat wyznaczono miary odpływu takie jak: współczynnik odpływu, wysokość warstwy odpływu, objętość odpływu. Wyznaczono również moc teoretyczną elektrowni, w oparciu o przepływ średni w wybranych latach oraz przepływ najdłużej trwający. W badanym cieku stwierdzono występowanie ośmiu gatunków ryb. Po względem elementów: biologicznych, hydromorfologicznych i fizykochemicznych z lat 2012 i 2015, potencjał ekologiczny JCWP jest jedynie umiarkowany, a tym samym stan jednolitej części wód – zły.
In this article, the Authors presented an analysis of hydrological and environmental conditions in the aspect of the location of a small hydropower plant on the Budkowiczanka River. The catchment of the Budkowiczanka River is A = 232 km2 and it’s located in south-western Poland in the Opolskie Province. The length of the Budkowiczanka River is about 60 km. The authors proposed the location of a small hydropower at 20,142 km of its run in Okoły-Kupi Las in the Murów commune. The analyzed cross-section should be included in the body of surface water „Budkowiczanka from Wisznia to Stobrawa”. The weir planned for the purposes of small hydropower is located approximately 1.7 km above the Krzywa Góra gauging station. Hydrological conditions were analyzed in the Budkowiczanka River for the Krzywa Góra profile. For the hydrotechnic purposes states and discharges were determined. Based on the annual sums of precipitations for the Opole station, from the multi-year period of 1981–2015, very dry and dry years have been designated. This station is located near the Budkowiczanka River catchment. For these years, outflow measures were determined such as: outflow coefficient, height of the outflow layer, outflow volume. The theoretically available power of the hydropower plant was also determined, based on the average flow and the longest running flow in the selected years. In the studied river, eight species of fish were found. In terms of biological, hydromorphological and physicochemical elements from year 2012 and 2015, the ecological potential of surface water body is only moderate, and thus the status of water body is bad.
Źródło:
Inżynieria Ekologiczna; 2018, 19, 6; 103-113
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie wskaźników makrofitowych w ocenie presji wód kopalnianych na wody rzeczne
Use of macrophyte indices in evaluation of the mine waters pressure on river waters
Autorzy:
Staniszewski, R.
Jusik, S.
Powiązania:
https://bibliotekanauki.pl/articles/61563.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
wody kopalniane
oddzialywanie na srodowisko
wody rzeczne
trofia
makrofity
indeks IBMR
indeks MTR
wskaznik makrofitowy RI
indeks RMNI
Opis:
Wskaźniki makrofitowe, takie jak Mean Trophic Rank (MTR), Macrophyte Biological Index for Rivers (IBMR), River Macrophyte Nutrient Index (RMNI), Reference Index (RI) i inne są z powodzeniem wykorzystywane w ocenie jakości ekosystemów rzecznych. Opierają się one głównie na tolerancji poszczególnych taksonów roślin naczyniowych, mszaków, wątrobowców i makroglonów na trofię wody. Oceniany odcinek rzeki Noteć znajdujący się powyżej jeziora Gopło odbiera zrzuty wód kopalnianych z odkrywki węgla brunatnego Tomisławice. W 2012 roku przeprowadzono badania dotyczące wpływu wód kopalnianych z odkrywki węgla brunatnego na trofię wód Noteci. Wykorzystano w tym celu kilka wskaźników makrofitowych oraz przeprowadzono analizy wskaźników troficznych na wybranych stanowiskach. Dla wybranych stanowisk dysponowano także wynikami badań z 2008 roku, które wykorzystano w celach porównawczych. Na podstawie uzyskanych wyników można stwierdzić, że wpływ charakterystyki troficznej wód kopalnianych na wielkości wskaźników makrofitowych oraz wskaźników jakości wody był nieznaczny. Wynika to z małych różnic trofii wód rzecznych i wód kopalnianych oraz braku wrażliwości wykorzystanych wskaźników makrofitowych na wypadnięcie pojedynczych gatunków wskaźnikowych z grupy roślin wodnych. Rośliną, która wypadła z listy makrofitów poniżej dopływu rzeki Pichny był grążel żółty, a niektóre wykazywały znaczny spadek pokrycia bez istotnego wpływu na wartości wskaźników makrofitowych. Świadczy to o niezbyt wysokiej czułości tego typu wskaźników w sygnalizowaniu nieznacznych zmian w środowisku wodnym.
Macrophyte indices, as like Mean Trophic Rank (MTR), Macrophyte Biological Index for Rivers (IBMR), River Macrophyte Nutrient Index (RMNI), Reference Index (RI) and other are successfully used in evaluation of river ecosystems. They based on tolerance of particular vascular plants, mosses, liverworts and macroalgea on water trophy. Studied part of Noteć River was situated above Gopło Lake and accept mine waters discharge from open-pit mine Tomisławice. In the year 2012 the analyses of the impact of brown coal mine waters on Noteć River trophy were carried out. Several macrophyte indices were used and supported by chemical analyses in selected sites. For all sites earlier data were accessible and were used to comparisons. On the base of obtained results it was concluded, that the impact of mine waters trophic characteristics on macrophyte indices and water trophy was generally negligible. It was due to the small differences of trophy between river and mine waters and lack of sensitivity of macrophyte indices on lack of individual indicator species from the group of aquatic vascular plants. Yellow Water-lily was the wasted species and significant decrease of cover was found for other species without changes of macrophyte indices values. It showed to some extent lack of sensitivity of macrophyte indices in detecting of slight changes of aquatic environment.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2014, III/1
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An analysis of flooding coverage using remote sensing within the context of risk assessment
Autorzy:
Solovey, Tatiana
Powiązania:
https://bibliotekanauki.pl/articles/94266.pdf
Data publikacji:
2019
Wydawca:
Uniwersytet im. Adama Mickiewicza w Poznaniu
Tematy:
Sentinel-2
Remote Sensing
flood mapping
Water Indexes
teledetekcja
mapowanie powodzi
wskaźnik wody
Opis:
Results of research of the identification of flooding as a result of groundwater table fluctuations on the example of the valley of the River Vistula, with the use of multi-spectral Sentinel-2 images from the years 2017-2018 are presented. An analysis of indexes of water use, calculated on the basis of green, red and shortwave infrared (SWIR) bands, for extraction of water objects and flooded areas was carried out. Based on the analyses conducted, a mapping method was developed, using three water indexes (MNDWI Modified Normalised Difference Water Index, NDTI Normalised Difference Index and NDPI Normalised Difference Pond Index). Results show that the 10 metre false colour composite RNDTIGNDPIBMNDWI obtained significantly improved submerged extractions more than did individual water indexes. Moreover, the 10-m-images of MNDWI and NDPI, obtained by the sharpening High Pass Filter (HPF), may represent more detailed spatial information on floods than the 20-m-MNDWI and NDPI, obtained from original images.
Źródło:
Geologos; 2019, 25, 3; 241-248
1426-8981
2080-6574
Pojawia się w:
Geologos
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ napowietrzania na zmianę agresywności korozyjnej wody podziemnej w stosunku do betonu i stali
The influence of aeration on the change of corrosive aggressiveness of groundwater in relation to concrete and steel
Autorzy:
Siwiec, T.
Michel, M.M.
Reczek, L.
Powiązania:
https://bibliotekanauki.pl/articles/40515.pdf
Data publikacji:
2016
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
woda
wody podziemne
napowietrzanie wody
odkwaszanie wody
agresywnosc korozyjna
indeks agresywnosci
wskaznik intensywnosci kwasowo-weglanowej
indeks nasycenia Langeliera
indeks Larsona-Skolda
indeks stabilnosci Ryznara
beton
stal
water
ground water
water aeration
deacidifaction
corrosive aggressiveness
aggressiveness index
Langelier Saturation index
Larson-Skold index
Ryznar Stability index
concrete
steel
Opis:
W pracy przedstawiono wyniki badań nad zmianami własności korozyjnych wody podczas jej napowietrzania. Zmiennymi niezależnymi były czas napowietrzania wody oraz natężenie przepływu powietrza, jak również wysokość warstwy wody. Mierzono parametry fizyczno-chemiczne wody, pozwalające określić zmiany jej właściwości za pomocą metod pośrednich. Zmiany agresywności korozyjnej wody oceniano za pomocą indeksu nasycenia Langeliera (LSI), indeksu stabilonści Ryznara (RSI), indeksu agresywności (AI), wskaźnika intensywności kwasowęglowej (I) oraz indeksu Larsona-Skolda (IL). Stwierdzono, że napowietrzanie znacząco zmniejsza korozyjność wody przez podnoszenie wartości pH, wiążące się z obniżaniem stężenia agresywnego CO2. Jednak bardzo niska zasadowość wody uniemożliwiła w eksperymencie osiągnięcie właściwości niekorozyjnych.
The results of investigation on changes of groundwater corrosiveness during aeration were presented. The independent variables were air flow rate, aeration time as well as water layer height. The physic-chemical parameters of water for determining the changes of its properties using indirect methods were measured. The changes of water corrosivity were evaluated using Langelier Saturation Index (LSI), Ryznar Stability Index (RSI), Aggressiveness Index (AI), Index of Intensity (I) and Larson-Skold Index (IL). It was found that aeration substantially decreases the corrosiveness of water by increasing pH value and decreasing the concentration of aggressive CO2. However, the very low alkalinity enables to achieve the non-corrosive properties of water.
Źródło:
Acta Scientiarum Polonorum. Architectura; 2016, 15, 1
1644-0633
Pojawia się w:
Acta Scientiarum Polonorum. Architectura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kształtowanie się potrzeb nawodnieniowych roślin sadowniczych w Polsce
Shaping of irrigation needs for fruit plants in Poland
Autorzy:
Rzekanowski, C.
Powiązania:
https://bibliotekanauki.pl/articles/62114.pdf
Data publikacji:
2009
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
Polska
sady
rosliny sadownicze
potrzeby wodne
klimatyczny wskaznik potrzeb wodnych
niedobor wody
potrzeby nawadniania
Opis:
W pracy przedstawiono kształtowanie się potrzeb nawodnieniowych roślin sadowniczych w Polsce, opierając się na formule N = P – Po [mm], w której N to niedobory wody [mm] w danym okresie, P – opady rzeczywiste [mm] w danym okresie, a Po – opady optymalne (potrzeby wodne roślin). Opady optymalne przyjęto wg zmodyfikowanej tabeli Pressa [1963], zawierającej potrzeby wodne roślin w mm na glebach ustalone dla trzech zakresów temperatur powietrza, w kolejnych miesiącach sezonu wegetacji. Potrzeby N określono w 27 wybranych stacjach meteorologicznych, dla pięciu podstawowych gatunków drzew owocowych oraz truskawek. Najwyższe niedobory wodne drzew owocowych stwierdzono w pasie środkowym Polski z odejściem na północ do Szczecina oraz w rejonie Poznania, Płocka i Słubic. Kształtowały się one w sezonie wegetacyjnym, przy wysokich temperaturach powietrza, w przypadku śliw na poziomie od 160 do 190 mm, jabłoni 140–171 mm, grusz 50–81 mm oraz wiśni i czereśni 39–73 mm. Korzystniejsze warunki wilgotnościowe panowały w obu skrajnych pasach kraju, chociaż i tu występowały potrzeby nawadniania, szczególnie w stosunku do śliw i jabłoni. Najwyższe niedobory opadów dla tych roślin stwierdzono w rejonach Białegostoku i Gdańska w pasie północnym oraz Lublina i Puław w południowym. Obliczono również niedobory wody N w okresach nawodnieniowych określonych osobno dla każdego gatunku drzew owocowych. Stwierdzono, że największe niedobory wody również występowały w środkowym pasie kraju, a najmniejsze w południowym. W przypadku wysokich temperatur powietrza, niedobory opadów w Krainie Wielkich Dolin z reguły przekraczały 100 mm dla jabłoni i wahały się od 73 do 108 mm dla śliw. Szczególnie duże niedobory wody były w okresie nawodnieniowym w rejonie Poznania, Szczecina i Kalisza. Natomiast przy dobrym rozkładzie opadów nie zachodziłaby potrzeba nawadniania grusz, wiśni i czereśni w całym pasie południowym, a najwyższe deficyty wody występowały w przypadku uprawy jabłoni i śliw, bo sięgające 50–75 mm, szczególnie w rejonie Lublina, Puław i Wrocławia. W pasie północnym Polski niedobory opadów przekraczały 50 mm, dochodząc do 82 mm w rejonie Białegostoku. Najmniejsze niedobory dotyczyłyby śliw.
Irrigation needs of orchard plants in Poland are presented in the work using the formula N = P – Po (mm), where: N – water needs (mm) in a given period, P – actual rainfall (mm) in a given period, Po – optimum rainfall (water needs of plants). Optimum rainfall amounts according to modified schedule of Press [1963] for three ranges of air temperature in the particular months of the vegetation period were taken into consideration. Needs N were determined for 27 chosen meteorological stations, for five fruit trees' basic species as well as strawberries. The higher water needs for fruit trees were determined in central belt of Poland with north region of Szczecin as well as regions of Poznań, Płock and Słubice. These needs in the vegetation period with high temperatures ranged from 160 to 190 mm for plum trees, 140–171 mm for apple trees, 50–81 mm for pear trees as well as 39–73 mm for sweet and sour cherries. Advantageous moisture conditions were determined in both extreme belts of country, but also here irrigation needs were occurred in case of plum-trees and apple-trees. The highest rainfall deficits were detected in regions Białystok and Gdańsk in northern belt as well as Lublin and Puławy in south. Water deficits N were also calculated for irrigation periods for particular fruit tree species. It was found that the highest water deficits occurred in central belt of country, and the smallest – in south. In case of high temperatures of air, rainfall shortages in Land of Great Valleys were usually above 100 mm for apple trees, and they ranged from 73 to 108 mm for plum trees. The particularly large shortages of water were during the irrigation period in regions of Poznań, Szczecin and Kalisz. In case of advantageous rainfall schedule, one need would not set the irrigation of pear trees, sour cherry-trees and sweet cherry trees in whole south belt. The highest water deficits occurred in case of apples and plums ranging 50–75 mm, particularly in region of Lublin, the Puławy and Wroclaw. In northern belt of Poland the shortages of falls crossed 50 mm, coming to 82 mm in region of Białystok. The smallest shortages would concern plum-trees.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2009, 03
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Spatiotemporal evolution of land surface temperature of Lake Oubeira catchment, northeastern Algeria
Przestrzenne i czasowe zmiany temperatury powierzchni ziemi w zlewni jeziora Oubeira w północnowschodniej Algierii
Autorzy:
Rezzag Bara, Chouaib
Djidel, Mohamed
Medjani, Fethi
Labar, Sofiane
Powiązania:
https://bibliotekanauki.pl/articles/292503.pdf
Data publikacji:
2019
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
emissivity
lake basin
land surface temperature (LST)
normalized different vegetation index (NDVI)
SEBAL
water surface temperature (WST)
emisyjność
model SEBAL
temperatura powierzchni wody (WST)
temperatura powierzchni ziemi (LST)
zlewnia jeziora
znormalizowany różnicowy wskaźnik wegetacji (NDVI)
Opis:
The difficulties of access and detailed measurements of land surface temperature (LST) and water surface temperature (WST) especially in wetlands made the use of remote sensing data as one of the sources and techniques to estimate many climate elements including surface temperature and surface emissivity (ɛ). This study aims to estimate the surface temperature of the wetland of Lake Oubeira located in northeastern Algeria and their spatiotemporal evolution in both land and water. Landsat OLI-TIRS images in two dates (April and September 2016) obtained from the USGS have been used in this work, and forms the basis of a series of operations to obtain the final LST: development of the normalized difference vegetation index (NDVI), conversion of the digital number (DN) of the thermal infrared band (TIR) into spectral radiance as well as the calculation of the effective luminosity temperature of the sensor from the spectral radiation and surface emissivity (ɛ). The results show that the LST varies in space and time (from 16 to 31°C in April and from 24 to 41°C in September). This implies that the absorption of the equilibrium temperature at land cover depends on the optical properties of the surface, which are essentially determined by its water content, colour and morphology. At the same time, the water surface is the lowest land cover temperature, which also has a spatial variation (from 19 to 25°C in April and from 26 to 34.5°C in September) induced by atmospheric temperature, wind direction and speed and the depth of the lake.
Trudności w dostępie do badanych obszarów i w wykonaniu szczegółowych pomiarów temperatury powierzchni ziemi (LST) i wody (WST), szczególnie w środowiskach podmokłych, sprawiają, że dane pozyskane metodą teledetekcji są źródłem informacji do szacowania elementów klimatu takich jak temperatura powierzchni i emisyjność (ɛ). Celem przedstawionych badań było określenie temperatury powierzchni siedlisk podmokłych jeziora Oubeira w północnowschodniej Algierii i jej zmian zarówno na ziemi, jak i w wodzie. W pracy wykorzystano obrazy Landsat OLI-TIRS z dwóch terminów (kwiecień i wrzesień 2016 r.) uzyskane z United States Geological Survey (USGS). Stanowiły one podstawę działań zmierzających do uzyskania końcowej temperatury LST – uzyskanie znormalizowanego różnicowego wskaźnika wegetacji (NDVI), konwersję numeru DN termicznego pasma podczerwieni (TIR) do spektralnej radiancji oraz obliczenie efektywnej temperatury barwowej sensora ze spektralnego promieniowania i emisyjności powierzchniowej (ɛ). Wyniki wskazują, że LST zmienia się w czasie i w przestrzeni (od 16 do 31°C w kwietniu i od 24 do 41°C we wrześniu). Oznacza to, że absorpcja temperatury przez pokrycie powierzchni ziemi zależy od optycznych właściwości powierzchni, które są określone przez zawartość wody, barwę i morfologię. Najniższą temperaturę wykazuje powierzchnia wody. Temperatura wody także ulega zmianom (od 19 do 25°C w kwietniu i od 26 do 34.5°C we wrześniu), wywołanym przez temperaturę powietrza, kierunek i prędkość wiatru oraz głębokość jeziora.
Źródło:
Journal of Water and Land Development; 2019, 43; 151-157
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza czynników formujących skład chemiczny wód podziemnych na stacjach badawczych w Warszawie i Radostowie
Factors controlling chemical composition of groundwater at the research stations in Warsaw and Radostowo
Autorzy:
Porowska, D.
Małecki, J. J.
Powiązania:
https://bibliotekanauki.pl/articles/2062806.pdf
Data publikacji:
2009
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
skład chemiczny wód podziemnych
typ hydrochemiczny wody
wskaźnik nasycenia
procesy hydrogeochemiczne
chemical composition of groundwater
hydrogeochemical type of water
saturation index
hydrogeochemical processes
Opis:
Badania były prowadzone w stacji zlokalizowanej w Warszawie (centralna część Polski) i Radostowie (północna część Polski). Wody podziemne z warstw czwartorzędowych, oligoceńskich i mioceńskich, ujmowane za pomocą piezometrów lub studni wierconych, analizowano w okresie od 1991 do 2007 r. W Warszawie skład chemiczny wód podziemnych wykazywał pionową zmienność. Wody najpłytszej strefy charakteryzowały się typem hydrochemicznym HCO3-C1-(SO4)-Ca-(Na), natomiast strefy najgłębszej - HCO3-Cl-Na-Ca. W Radostowie wody wykazywały mniejszą zmienność w profilu pionowym i głównie charakteryzowały się typem HCO3-Ca-(Mg). Czynnikami wpływającymi na zróżnicowanie składu chemicznego wód podziemnych obu stacji są inne procesy hydrogeochemiczne, wynikające z odmiennych warunków zasilania i drenażu.
The research was conducted at the research station in Warsaw (central Poland) and Radostowo (northern Poland). Groundwater of Quaternary, Miocene and Oligocene aquifers, collected from piezometers and wells, was examined during a 17-years period of 1991-2007. In Warsaw, the chemical composition of groundwater changes with depth. The shallowest water samples are of HCO3-C1-(SO4)-Ca-(Na) types, whereas the deepest ones are represented by HCO3-Cl-Na-Ca types. In Radostowo, the vertical distribution of hydrogeochemical type of groundwater was constant: HCO3-Ca-(Mg). The difference in groundwater recharge within the Major Groundwater Basin and the diversification of hydrogeochemical processes are the major factors controlling the chemical composition of water.
Źródło:
Biuletyn Państwowego Instytutu Geologicznego; 2009, 436, z. 9/2; 379-386
0867-6143
Pojawia się w:
Biuletyn Państwowego Instytutu Geologicznego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The possibility of using Lake Rawa Pening as a source of drinking water
Możliwość wykorzystania jeziora Rawa Pening jako źródła wody pitnej
Autorzy:
Piranti, Agatha
Waluyo, Gentur
Rahayu, Diana R. U .S.
Powiązania:
https://bibliotekanauki.pl/articles/292441.pdf
Data publikacji:
2019
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
drinking water
Lake Rawa Pening
Storet index
water quality standards
jezioro Rawa Pening
normy jakości wody
woda pitna
wskaźnik Storet
Opis:
The water of Lake Rawa Pening is used as a source of drinking water. Indonesian Government Regulation Number 82 of 2001 on Management of Water Quality and Water Pollution Control stated that the water quality of Lake Rawa Pening should meet the quality standard of first grade and be categorized as no polluted water. The purpose of this research was to assess the water quality based on Indonesian regulation and to assess water quality based on international regulations. The quality of water was assessed using a survey method in 7 sites of the Lake Rawa Pening 3 times for 3 months. Parameters measured were all the water quality parameters required in accordance with Government Regulation No. 82 of 2001. The results indicated that there were 13 values that exceeded the water quality standard of first grade. These exceeded parameters were total suspended solids (TSS), biological oxygen demand (BOD), chemical oxygen demand (COD), orthophosphate (PO4), NO3, As, Se, Cd, Mn, Cu, Pb, H2S, faecal coliform, and total coliform. Water quality status of Lake Rawa Pening was categorized as heavily polluted. The water quality of Lake Rawa Pening should be improved by reducing the pollutants entering the lake by restriction of human activities causing lake pollution.
Woda jeziora Rawa Pening jest wykorzystywana jako źródło wody pitnej. Rozporządzenie rządu Indonezji nr 82 z 2001 r. o zarządzaniu jakością wody i kontroli zanieczyszczeń stwierdza, że woda jeziora powinna spełniać standardy jakości wody pierwszego stopnia i być klasyfikowana jako woda pozbawiona zanieczyszczeń. Celem badań była ocena jakości wody według indonezyjskich i międzynarodowych norm. Jakość wody oceniano w 7 stanowiskach jeziora trzykrotnie w ciągu 3 miesięcy. Mierzone parametry odpowiadały zawartym w rozporządzeniu nr 82 z 2001 roku. Wyniki analiz wykazały, że 13 parametrów przekracza dopuszczalne normy przewidziane dla 1 klasy czystości. Te parametry to: zawiesina całkowita (TSS), biochemiczne i chemiczne zapotrzebowanie na tlen (BOD, COD), fosforany, azotany, As, Se, Cd, Mn, Cu, Pb, H2S, bakterie E. coli i bakterie z grupy coli. Stan wód jeziornych określono jako silnie zanieczyszczone. Jakość wody jeziora Rawa Pening powinna ulec poprawie przez ograniczenie ładunku zanieczyszczeń doprowadzanych do jeziora wskutek działalności człowieka.
Źródło:
Journal of Water and Land Development; 2019, 41; 111-119
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Plankton jako wskaźnik klasy czystości wody
Plankton as the water quality class indicator
Autorzy:
Piontek, M.
Łuszczyńska, K.
Awińska-Więckowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/372163.pdf
Data publikacji:
2010
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
trofia zbiorników wodnych
eutrofizacja
plankton
wskaźnik czystości wody
analiza fizykochemiczna
analiza biologiczna
jezioro Droszków
trophy
eutrophication
water quality
biological analysis
Droszków lake
Opis:
Na przełomie lipca, sierpnia i września obserwowano zróżnicowanie gatunkowe planktonu jeziora Droszków w województwie lubuskim, gminie Zabór. Ponadto wykonane zostały badania sanitarne wody jeziora przeprowadzone w Zakładzie Uzdatniania Wody (ZUW) w Zielonej Górze oraz badania fizykochemiczne przeprowadzone przez centralne laboratorium Instytutu Inżynierii Środowiska Uniwersytetu Zielonogórskiego. Celem prowadzonych obserwacji była ocena jakości wody jeziora Droszków i określenie metodą biologiczną jego klasy czystości. W drugiej połowie sierpnia zaobserwowano zakwit sinic. Gatunkiem dominującym były Mikrocystis flos-aque oraz Anabaena solitaria. Bardzo licznie występowały też złotowiciowce, a w szczególności Synura uvella i Dinobryon divergens. W prowadzonych badaniach skupiono się na określeniu stopnia klasy czystości wody jeziora poprzez obserwację mikroskopową planktonu. Dla porównania przydatności metody biologicznej wykonano badania fizykochemiczne i sanitarne. Wyniki przeanalizowano zgodnie z Rozporządzeniem Ministra Środowiska z dnia 11 lutego 2004 r. w sprawie klasyfikacji dla prezentowania stanu wód powierzchniowych i podziemnych, sposobu prowadzenia monitoringu oraz sposobu interpretacji wyników i prezentacji stanu tych wód (Dz. U. Nr 32, poz. 284).
The purpose of the diploma paper was analyzing literature on the subject of trophy and eutrophication of water reservoirs, water quality in lubuskie province and review and description of water microorganisms and their place in a lake to perform biological analysis of water quality class based on the collected plankton samples. In July, August and September different species of plankton of the lake Droszków in Lubuskie province, commune Zabor were observed. Moreover sanitary tests of the lake were performed in Water Treatment Station (ZUW) in Zielona Góra and furthermore physicochemical tests were made by the central laboratory of the Institute of Environment Engineering of the University of Zielona Góra. The purpose of conducted observation was evaluation of the water quality of Droszków lake and specifying its quality class using biological method. In the second half of August cyanobacterial blooms was observed. The dominating species were Microcystis flos-aque and Anabaena solitaria. Numerous Chrysophyceae were also observed in particular Synura uvella and Dinobryon divergens. The conducted research focused on definition of the quality class of the lake water by microscopic observation of plankton. To compare the relevance of biological method also physicochemical and sanitary tests were made. The results were analyzed according to the Regulations of the Minister of Environment dated 11.02.2004 on classification the condition of surface and underground water, monitoring method and results interpretation and finally presentation of such water quality (J.o.L. No. 32, item 284).
Źródło:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski; 2010, 140 (20); 50-73
1895-7323
Pojawia się w:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of chemical stability of tap water in terms of required level of technological safety
Analiza stabilności chemicznej wody wodociągowej pod kątem wymaganego poziomu bezpieczeństwa technologicznego
Autorzy:
Pietrucha-Urbanik, K.
Tchórzewska-Cieślak, B.
Papciak, D.
Skrzypczak, I.
Powiązania:
https://bibliotekanauki.pl/articles/205102.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
chemical stability of water
corrosion indice
technological safety
risk criteria
stabilność chemiczna wody
wskaźnik korozji
bezpieczeństwo technologiczne
kryteria ryzyka
Opis:
The main goal of this work is to show the new approach to determining safety technological levels (SLs) in terms of water quality and its chemical stability, as well as issues of water corrosion properties in water distribution systems (WDSs), due to the fact that water supply pipes are prone to corrosion. In the paper the methodology of determining the risk associated with threat to technical infrastructure was considered. The concept was studied on the basis of real operational data from the water treatment plant. The probability of exceeding the individual parameters for WTPI is slightly larger than for WTPII, which means that this water treatment process may cause lack of chemical stability in the water supply network. Operators should anticipate in the process of designing water distribution system, using proper materials, as to ensure an adequate level of safety from the water source to the water recipient. It should be noted that it is necessary to adjust the material of internal installation of water supply networks to the parameters of the water. At present, there are no correlations between the designing step and water parameters. It was concluded that to protect the water supply infrastructure, which belongs to critical infrastructure, water company should put more emphasis on distribution of stable water that has not potentially corrosion properties. Some suggestions were made for the protection of WDS and to ensure safety of system functioning and long-term usability of water pipes.
Głównym celem pracy jest przedstawienie nowego podejścia do określania poziomów technologicznych bezpieczeństwa (SL) w zakresie jakości wody i jej stabilności chemicznej, a także właściwości korozyjnych wody w systemach dystrybucji wody (WDS), ze względu na fakt, iż przewody wodociągowe są podatne na korozję. W pracy przedstawiono metodologię określania ryzyka związanego z wystąpieniem zagrożeń dla infrastruktury technicznej. Analiza została wykonana na podstawie uzyskanych danych eksploatacyjnych ze stacji uzdatniania wody. Prawdopodobieństwo przekroczeń poszczególnych parametrów w przypadku WTPI jest nieznacznie większe od WTPII, co oznacza iż ten proces uzdatniania wody może powodować brak zachowania stabilności chemicznej w sieci wodociągowej. Operatorzy powinni przewidzieć w procesie projektowania systemu dystrybucji wody, użycie odpowiednich materiałów, tak aby zapewnić odpowiedni poziom bezpieczeństwa od źródła wody do odbiorcy. Należy zauważyć, że niezbędne jest dostosowanie materiału wewnętrznej instalacji sieci wodociągowej do parametrów wody nie odwrotnie. W chwili obecnej nie ma korelacji pomiędzy etapem projektowania, a parametrami wody. W celu ochrony infrastruktury wodociągowej, które należą do infrastruktury krytycznej, przedsiębiorstwo wodociągowe powinna położyć większy nacisk na dystrybucję stabilnej wody, która nie ma właściwości korozyjnych. W pracy zaproponowano podjęcie działań zapewniających ochronę systemu dystrybucji wody przed utratą stabilności chemicznej wody.
Źródło:
Archives of Environmental Protection; 2017, 43, 4; 3-12
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis and Evaluation of Water Losses in the Collective Water Supply System
Analiza i ocena strat wody w wybranym wodociągu grupowym
Autorzy:
Ociepa, Ewa
Powiązania:
https://bibliotekanauki.pl/articles/1812009.pdf
Data publikacji:
2019
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
water losses
percentage water loss index
infrastructure leakage index
unit water start index
failure intensity index
straty wody
procentowy wskaźnik wody
infrastrukturalny indeks wycieków
jednostkowe wskaźniki start wody
wskaźnik intensywności uszkodzeń sieci wodociągowej
Opis:
The paper presents the analysis and evaluation of water losses in the distribution system used by the Water and Sewage Company in Końskie, Poland. The analysis of water losses was conducted based on the use of numerous indices that provide objective information on the condition of the water supply system. The method of the percentage water loss index was extended by the methods of determination of water losses according to the International Water Association (IWA). The data needed for the calculation of water losses, such as the amount of water supplied to the network, the water sold, water used for the company's own needs, the length of the network, the number and length of water supply connections, number of customers, mean pressure in the network, and number of failures was derived from Water and Sewage Company in Końskie, Poland. These data were used to calculate the amount of water losses in individual years, percentage water loss index (PWS), and the indices recommended by the International Water Association (IWA): Real Leakage Balance (RLB), Non-Revenue Water Basic (NRWB), Unavoidable Annual Real Losses (UARL), Infrastructure Leakage Index (ILI) and unit indices of loss per capita and per kilometre of network. Due to the likely relationships of the load and failure rate of the network with water losses, the failure intensity index and index of hydraulic load to the network. The results of the analysis showed that with its comprehensive activities, the company has significantly reduced its water losses in recent years. Currently, most of the water loss indices have reached a level considered good compared to the national data and average according to the standards used in Western European countries. In 2012, most of the analysed loss indices were at a high or even very high level and showed higher than the national average loss of network water. The decrease of the NRWB index from 29% in 2012 to ca. 18% in 2018, and the decrease of the ILI value in the respective years from 3.1 to 1.5-1.6 indicate the effective countermeasures used to limit water losses. Currently, the value of IMI according to strict IWA criteria suggests a very good condition of the network. RLB2 is another indicator that fell sharply over the period analysed. In 2012, its value was more than twice as high as at present. On the other hand, the average condition of the network is indicated by the unit water loss index per capita, which amounted to 52.80 in 2012 and currently is about 23.07 dm3/(inhabitant day). Very low values of the failure intensity index of the water supply system indicate that the impact of failures on water losses is insignificant, assuming that the company responds quickly to remove identified leaks and there are no undetected failures. The several years of analysis and evaluation of numerous indices of water loss presented in the paper reveals the effectiveness of the adopted strategies of reducing leakages in the distribution system. It should be noted that the company has been involved in comprehensive activities aimed at limitation of water losses for several years.
W artykule przedstawiono analizę i ocenę strat wody w systemie dystrybucji eksploatowanym przez Przedsiębiorstwo Wodociągów i Kanalizacji w Końskich. Analizę strat wody przeprowadzono w oparciu o liczne wskaźniki pozwalające na obiektywną informację o stanie sieci wodociągowej. Metoda procentowego wskaźnika strat wody rozszerzona została o metody określania strat według International Water Association(IWA). Niezbędne dane do obliczeń strat wody jak: ilość wody dostarczanej do sieci, wody sprzedanej, zużytej na potrzeby własne zakładu, długość sieci, ilość i długość połączeń wodociągowych, liczbę odbiorców, średnie ciśnienie w sieci, liczba awarii otrzymano z Przedsiębiorstwa Wodociągów i Kanalizacji w Końskich. Na ich podstawie wyznaczono: ilość strat wody w poszczególnych latach, procentowy wskaźnik strat wody (PWS), a także zalecane przez International Water Association (IWA) wskaźniki: Real Leakage Balance (RLB), Non-Revenue Water Basic (NRWB), Unavoidable Annual Real Losses (UARL), Infrastructure Leakage Index (ILI) oraz wskaźniki jednostkowe strat na mieszkańca i kilometr sieci. Z uwagi na możliwy związek obciążenia i awaryjności sieci ze stratami wody wyznaczono wskaźnik intensywności uszkodzeń i wskaźnik hydraulicznego obciążenia sieci. Wyniki przeprowadzonej analizy pozwalają stwierdzić, że dzięki wszechstronnym działaniom przedsiębiorstwo w ostatnich latach zdecydowanie obniżyło straty wody. Obecnie większość wskaźników strat wody osiągnęło poziom uznany za dobry na tle danych krajowych a średni w odniesieniu do standardów krajów Europy zachodniej. W 2012 roku większość analizowanych wskaźników strat była na wysokim a nawet bardzo wysokim poziomie i świadczyła o wyższych niż średnie krajowe ubytkach wody z sieci. Spadek wskaźnika strat NRWB z 29% w 2012 roku do ok. 18% w 2018, spadek wartości wskaźnika ILI w tym okresie z 3,1 do 1,5-1,6 świadczy o skutecznym przeciwdziałaniu stratom wody. Obecnie wartość ILI według rygorystycznych kryteriów IWA świadczy o bardzo dobrym stanie sieci. Kolejnym wskaźnikiem, który uległ w analizowanym okresie poważnemu obniżeniu jest RLB2. W 2012 wartość jego była ponad dwukrotnie wyższa niż obecnie. Natomiast na średni stan sieci wskazuje jednostkowy wskaźnik strat wody na mieszkańca, który wynosił 52,80 w 2012 roku a obecnie ok. 23,07 dm3/(mieszkańca/dobę). Bardzo niskie wartości wskaźnika intensywności uszkodzeń sieci wodociągowej wskazują na mało znaczący wpływ awarii na straty wody przy założeniu, że Zakład szybko reaguje i usuwa stwierdzone wycieki i nie występują awarie nieujawnione. Analiza i ocena na przestrzeni lat licznych wskaźników strat wody przedstawiona w artykule świadczy o skuteczności przyjętych strategii ograniczania wycieków w systemie dystrybucji. Należy podkreślić, że przedsiębiorstwo od kilku lat prowadzi wszechstronne, kompleksowe działania zmierzające do ograniczania strat wody.
Źródło:
Rocznik Ochrona Środowiska; 2019, Tom 21, cz. 2; 1021-1039
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies