Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "wody geotermalne" wg kryterium: Temat


Tytuł:
The simpliefied estimation of wellhead pressure in reinjection geothermal processes
Uproszczone szacowanie wartości ciśnienia głowicowego w procesach reiniekcji geotermalnej
Autorzy:
Nagy, S.
Powiązania:
https://bibliotekanauki.pl/articles/299939.pdf
Data publikacji:
2007
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
wody geotermalne
powtórne zatłaczanie
geothermal waters
reinjection
Opis:
Exploitation and reinjection of geothermal waters after partial recuperation of their enthalpy has become a world's common. Two types of reservoir collectors can be encountered in the Poland: pore- and fracture-type collectors. Physical phenomena related with the injection of fluids to the pore-and fracture-type medium can be divided into hydrodynamic (pressure and fracturing effects) and chemical/thermodynamic phenomena connected with a change of temperature and chemical composition of fluid. The classical formulas has been adopted to include rate depended skin, change viscosity and density of water with injection temperature. Chemical effects are not analyzed in this paper. Some conclusion related to reinjection processes have been included based upon own observation of injection processes in Poland.
Wydobycie i powtórne zatłaczanie wód geotermalnych po częściowym pozyskaniu ich entalpii stało się problemem na skalę światową. Na terenie Polski występują dwa rodzaje złóż kolektorowych: porowe oraz zczelinowo-porowe. Zjawiska fizyczne związane z zatłaczaniem płynów do porowego i szczelinowo-porowego zbiornika można podzielić na hydrodynamiczne (ciśnienie i szczelinowanie) oraz chemiczne/termodynamiczne zjawiska związane ze zmianą temperatury i składu chemicznego płynu. Wykorzystano klasyczne wzory z uwzględnieniem skin efektu wywołanego turbulencją przepływu w pobliżu odwiertu, zmianę lepkości i gęstości wody w zależności od temperatury zatłaczania. W artykule nie przeanalizowano zjawisk chemicznych. Niektóre wnioski związane z procesami powtórnego zatłaczania oparto na własnych obserwacjach procesów zatłaczania w Polsce.
Źródło:
Wiertnictwo, Nafta, Gaz; 2007, 24, 1; 341-346
1507-0042
Pojawia się w:
Wiertnictwo, Nafta, Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Właściwości fizykochemiczne i chemiczne wód geotermalnych w Uniejowie ze szczególnym uwzględnieniem wody z odwiertu PIG/AGH-2
Physical and chemical properties of geothermal waters and their use in medicine with particular focus on well PIG/AGH-2 in Uniejów
Autorzy:
Latour, Teresa
Smętkiewicz, Karolina
Powiązania:
https://bibliotekanauki.pl/articles/487421.pdf
Data publikacji:
2012
Wydawca:
Uniwersytet Łódzki. Wydawnictwo Uniwersytetu Łódzkiego
Tematy:
uzdrowisko Uniejów
wody geotermalne
zastosowanie medyczne wód geotermalnych
Opis:
Temperature of groundwater was its earliest recognized healing property and indication for using it for therapeutic bath and other treatments. Later on the chemical composition of water was found to have influence on human body by intensifying the thermal impact of water. The chemical composition may also reduce the suitability of water for general use. Geothermal waters were used in Poland for therapeutic bath until the end of the 20th century, mainly in Cieplice, Lądek-Zdrój, Ciechocinek i Ustroń Śląski. As a result of geological research carried out during the last 20 years, geothermal waters having temperature > 90°C were found in several places, mainly in Polish Lowlands (also in the vicinity of Łódź). Fairly large resources of these waters and their diversity in terms of chemical composition create possibilities of their exploitation for many purposes, especially if water intakes are placed near large cities or in areas attractive for tourists. Uniejów – the youngest thermal spa in Poland and the only such health resort in Łódź voivodship – is an example of using thermal water for balneotherapeutic purposes.
Źródło:
Biuletyn Uniejowski; 2012, 1; 79-93
2299-8403
Pojawia się w:
Biuletyn Uniejowski
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Geothermal waters reinjection into sandstones and carbonate reservoir rocks
Powtórne zatłaczanie wód geotermalnych do warstw piaskowców i węglanowych skał zbiornikowych
Autorzy:
Nagy, S.
Soboń, J.
Powiązania:
https://bibliotekanauki.pl/articles/299941.pdf
Data publikacji:
2007
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
eksploatacja
wody geotermalne
powtórne zatłaczanie
exploitation
geothermal waters
reinjection
Opis:
Exploitation and reinjection of geothermal waters after partial recuperation of their enthalpy has become a world's common practice since the 1970s. Recently the "used" thermal waters have been usually injected to the pore- and fracture-ype collectors. There are two reasons for which injection methods are applied in low: to maintain the formation pressure (especially important for high enthalpy resources), and secondly, because of environmental problems with discharging great amounts of saline waters (low enthalpy resources). Two types of reservoir collectors can be encountered in the geothemal formation in the Poland: pore- and fracture-type collectors. Physical phenomena related with the injection of fluids to the pore- and fracture-type medium can be divided into hydrodynamic (re-pressure and fracturing effects) and chemical/thermodynamic phenomena connected with a change of temperature and chemical composition of fluid. Some conclusion related to quality of reinjected waters has been included based upon literature and own observation of injection process in Poland.
Eksploatacja i powtórne zatłaczanie wód geotermalnych po częściowym pozyskaniu ich entalpii jest powszechnie stosowaną praktyką od lat siedemdziesiątych ubiegłego stulecia. W ostatnim czasie "zużyte" wody termalne zwykle zatłaczano do kolektorów porowych lub szczelinowo-porowych. Metody iniekcji stosuje się głównie z dwóch powodów: w celu utrzymania ciśnienia złożowego (szczególnie ważne w przypadku złóż o wysokiej entalpii) oraz ze względu na problemy ekologiczne związane z odprowadzeniem dużych ilości zasolonych wód (zasoby o niskiej entalpii). Dwa typy kolektorów występują na terenie Polski: porowe i szczelinowo-porowe. Zjawiska fizyczne związane z zatłaczaniem płynów do porowego i szczelinowo-porowego zbiornika można podzielić na hydrodynamiczne (odbudowa ciśnienia i szczelinowanie) oraz chemiczne/termodynamiczne zjawiska związane ze zmianą temperatury i składu chemicznego płynu. Niektóre wnioski związane z procesami powtórnego zatłaczania oparto na danych literaturowych oraz własnych obserwacjach procesów zatłaczania w Polsce.
Źródło:
Wiertnictwo, Nafta, Gaz; 2007, 24, 1; 347-354
1507-0042
Pojawia się w:
Wiertnictwo, Nafta, Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena możliwości wykorzystania wód geotermalnych na obszarze gminy Kęty
Evaluation of the possibility of using thermal waters in the municipality of Kęty
Autorzy:
Czechowska, B.
Barbacki, A.
Powiązania:
https://bibliotekanauki.pl/articles/203987.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
wody geotermalne
Kęty
ocena zasobów
rekreacja
thermal waters
resources estimation
recreation
Opis:
W pracy zostały zebrane dane dotyczące zasięgu, rozmieszczenia oraz potencjału cieplnego wód geotermalnych na terenie gminy Kęty oraz w jej bezpośrednim sąsiedztwie. Analizowany obszar zlokalizowany jest na pograniczu dwóch jednostek geologicznych: zapadliska przedkarpackiego oraz Karpat fliszowych. Na podstawie danych otworowych wykonano przekroje geologiczne z oznaczeniem stwierdzonych przypływów wód geotermalnych. Przedstawiono charakterystykę zbiorników i oszacowano ich parametry hydrogeotermalne. Dla wybranych zbiorników przeprowadzono obliczenia, mające na celu ocenę zasobów występujących w poszczególnych basenach. Analizy danych umożliwiły wskazanie najbardziej perspektywicznych zbiorników oraz obszarów i kierunków wykorzystania wód geotermalnych. Na podstawie obliczonych wartości cieplnego potencjału technicznego jako optymalny uznano zbiornik dewoński, dla którego zaproponowano wykorzystanie wód z tego zbiornika dla celów rekreacyjnych. Dodatkowo opracowano prosty schemat basenowej instalacji geotermalnej.
The main aim of the following thesis is to present data concerning the location and use of thermal waters in the municipality of Kęty and the surrounding areas. The described region is situated on the borderline of two geological units: the Carpathian Mountains and the Carpathian Hollow. Based on the well data, geological sections were carried out and places of thermal waters flow were noted. Then the characteristics of the thermal water reservoirs were presented and the hydrogeothermal parameters estimated. The data worked out in the article allows the most perspective areas and directions for use of thermal waters to be indicated. Based on the calculated value of the energetic potential of the Devonian reservoir, which is the most prospective, a simple scheme of geothermal pool installation was proposed.
Źródło:
Technika Poszukiwań Geologicznych; 2016, R. 55, nr 2, 2; 55-66
0304-520X
Pojawia się w:
Technika Poszukiwań Geologicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ składu chemicznego wody geotermalnej na koszty eksploatacji systemu ciepłowniczego w Pyrzycach
Impact of water chemical composition on exploitation coasts of geothermal heating plant in Pyrzyce
Autorzy:
Zieba, E.
Grzesiak, E.
Powiązania:
https://bibliotekanauki.pl/articles/61382.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
wody geotermalne
sklad chemiczny
systemy cieplownicze
urzadzenia techniczne
koszty eksploatacji
Pyrzyce
Opis:
W artykule przedstawiono problem wpływu składu chemicznego wód geotermalnych na urządzenia techniczne systemu ciepłowniczego w Pyrzycach, a tym samym na koszty jego eksploatacji. Omówiono także zasoby geotermalne w Polsce i zakres ich wykorzystania oraz scharakteryzowano złoże wód na terenie Pyrzyc. Oceny wpływu zasolenia wody geotermalnej na system ciepłowniczy dokonano na podstawie badań jej składu fizykochemicznego oraz dokumentacji technicznej dotyczącej eksploatacji geotermii. Stwierdzono bardzo dużą mineralizację wody rzędu 115,00 g/dm3, co było przyczyną kolmatacji otworów oraz korozji rur, mimo rozwiązań technicznych zastosowanych na etapie budowy instalacji. W rezultacie spowodowało to zwiększenie przewidywanych kosztów eksploatacji, a tym samym kosztów wytwarzania energii.
The article contains problems of impact of geothermal water chemical composition on technical devices of heating plant in Pyrzyce, and therefore the costs of its operation. The paper presents geothermal water resources in Poland and characteristics of water deposit in Pyrzyce. On the basis of the water chemical composition research and exploitation documentation an evaluation of influence on heating plant has been made. Based on the analysis, very high water mineralization of 115,00 g/dm3 has been found. It has caused pipes corrosion and silting-up holes despite the use of technical solutions for the construction of installations. In result, the increase of provided exploitation and energy costs has been observed.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2010, 08/1
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Możliwości wykorzystania wód termalnych występujących na terenie Wielkopolski do celów leczniczych i rekreacyjnych
Thermal waters in the Wielkopolska region and possibilities of their use for therapeutics and recreation
Autorzy:
Latour, T.
Drobnik, M.
Powiązania:
https://bibliotekanauki.pl/articles/2074786.pdf
Data publikacji:
2010
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
wody geotermalne chlorkowo-sodowe
Poznań
Czeszewo
Koszuty
sodium chloride thermal waters
Opis:
Wielkopolska is one of the few Polish provinces in which resources of ground waters useful for therapeutics and recreation are still untapped. These resources of C or B category were examined in 70-ties and 80-ties of the last century, when 70 deep exploratory boreholes had been done in Wielkopolska region. On the base of the results of physicochemical analysis indicated were different possibilities of exploitation of the water from boreholes located in: Koszuty - commune Słupca, borehole Środa IG-2, Czeszewo - commune Miłosław, borehole IG-1 and Poznań, nearby Malta Lake, borehole Swarzędz IGH-1. These boreholes were indicated because of their exploitable resources, water properties as well as natural landscape values of the spots, their infrastructure, climatic conditions and environmental factors. The water from these boreholes were categorized as sodium chloride thermal water of diverse total mineralization degree (0.46-1.79%) and temperature range 34-42oC. The particular waters from indicated boreholes are appropriate for many purposes as: recreation and therapy in their natural state.
Źródło:
Przegląd Geologiczny; 2010, 58, 7; 609-612
0033-2151
Pojawia się w:
Przegląd Geologiczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ temperatury wody geotermalnej na regulację ilościową i jakościową ciepłowni geotermalnej
Effect of geothermal water temperature on quantity and quality geothermal heat plant control
Autorzy:
Zwarycz-Makles, K.
Nowak, W.
Powiązania:
https://bibliotekanauki.pl/articles/203726.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
ciepłownie geotermalne
wody geotermalne
regulacja ilościowa
regulacja jakościowa
quantity control
quality control
geothermal heat plant
Opis:
Praca dotyczy zagadnień wykorzystywania energii wód geotermalnych w ciepłowni geotermalnej z regulacją ilościową oraz jakościową dla wariantu b4 i stanowi kontynuację badań opisywanych we wcześniejszych publikacjach autorów (warianty b1 i b5) np. Zwarycz-Makles, Nowak 2011. Analizowany układ ciepłowniczy składa się z następujących elementów: źródła ciepła (wymiennik geotermalny oraz kocioł szczytowy), przewodów sieci ciepłowniczej, odbiorców ciepła centralnego ogrzewania (wysoko- i niskotemperaturowych połączonych w układzie równoległym). W pracy przedstawiono wyniki obliczeń przeprowadzonych z użyciem opracowanego algorytmu obliczeń cieplno-przepływowych przy równoległym łączeniu różnotemperaturowych odbiorców ciepła z zastosowaniem regulacji ilościowej i jakościowej wraz z wykresami ilustrującymi uzyskane zależności regulacyjne dla wody sieciowej w ciepłowni geotermalnej. Podano także przykładowe wyniki obliczeń, które dotyczą dwóch grup odbiorców ciepła połączonych równolegle, przy zastosowaniu regulacji ilościowej i jakościowej.
Presented paper relates to aspects of geothermal energy utilization in a geothermal heat plant with quantity and quality control in the heat network for variant b4 and is a continuation of research described in earlier publications (variants b1 and b5) i.e. (Zwarycz-Makles, Nowak 2011). Analyzed heating system consists of the following elements: heat plant, district heating pipeline, heat consumers (radiator and floor central heating connected in parallel system). As a result of the work was developed thermal-hydraulic calculations algorithm for parallel system of connected consumers with quantity and quality control in the heating network. Graphs illustrating obtained water control relationships of district heating network were prepared. This article also provides examples of calculation results, which concern two groups of heat consumers connected in parallel, using quantity and quality control.
Źródło:
Technika Poszukiwań Geologicznych; 2013, R. 52, nr 2, 2; 167-178
0304-520X
Pojawia się w:
Technika Poszukiwań Geologicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania modelowe nad odżelazianiem wód geotermalnych na cele balneologiczne i rekreacyjne
Model study on deironing of geothermal water for balneologcal and recreation use
Autorzy:
Kłosok-Bazan, I.
Powiązania:
https://bibliotekanauki.pl/articles/203885.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
wody geotermalne
balneologia
odżelazianie
kąpiele
rekreacja
geothermal water
balneology
deironing
bath
recreation
Opis:
Wykorzystanie wód geotermalnych w balneologii i rekreacji pociąga za sobą konieczność ich uzdatniania ze względu na obecność domieszek, które pogarszają właściwości organoleptyczne wody i mogą negatywnie wpływać na stan obiektów i armatury. W pracy przedstawione zostaną wyniki badań nad odżelazianiem wód geotermalnych nad wpływem zasolenia i temperatury na efektywność tego procesu.
Use of geothermal water in balneology and recreation bring the necessity of treatment them, from considerations of harmful impurity presence. This work will present the results of research on deironing of geothermal water and on salinity and temperature influence on efficiency of this process.
Źródło:
Technika Poszukiwań Geologicznych; 2013, R. 52, nr 1, 1; 123-133
0304-520X
Pojawia się w:
Technika Poszukiwań Geologicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Właściwości biochemiczne wód geotermalnych rozpoznanych w Polsce określające sposób ich wykorzystania do celów leczniczych lub rekreacji
Geothermal waters recognized in Poland – biochemical properties determining their usefulness for medical treatment or recreation
Autorzy:
Latour, T.
Drobnik, M.
Powiązania:
https://bibliotekanauki.pl/articles/203919.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
wody geotermalne
balneologia
rekreacja
bezpieczeństwo zdrowotne
geothermal waters
balneology
recreation
health safety
Opis:
Na podstawie wyników analiz składu chemicznego wód geotermalnych rozpoznanych w około sześćdziesięciu ujęciach w różnych regionach Polski, wskazano czynniki warunkujące ich wykorzystanie do różnych celów. W opracowaniu tych wskazań uwzględniono: temperaturę wody, ogólną zawartość rozpuszczonych składników mineralnych oraz ich rodzaj (zwłaszcza dominujących ilościowo), a także zawartość składników biochemicznie aktywnych, tj. swoistych leczniczych lub potencjalnie szkodliwych dla zdrowia człowieka. Stężenie tych składników, zwłaszcza radonu, jodków i związków siarki (II), decyduje o sposobie wykorzystania wody i formach zabiegu, a także systemie funkcjonowania basenów kąpielowych.
On the waters intakes basis of obtained of the chemical composition analyses results of about 60 geothermal waters recognized in different regions in Poland, the conditions of their usefulness for various purposes were indicated. In determining of these conditions, the fallowing were defined water temperature, total amount of dissolved mineral compounds and types of mineral compounds (especially quantitative predominantly) and the content of biochemically active compounds – of specific therapeutic effectiveness or potentially harmful to human health. Concentration of biochemically active compounds, especially radon, iodides and sulphur (II) compounds determines usefulness of different kinds of water and forms of treatment among them procedures of functioning basins for recreation and therapeutic purposes.
Źródło:
Technika Poszukiwań Geologicznych; 2016, R. 55, nr 1, 1; 67-74
0304-520X
Pojawia się w:
Technika Poszukiwań Geologicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie wód termalnych w Polsce (stan na rok 2009)
The use of geothermal waters in Poland (state in 2009)
Autorzy:
Bujakowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/2074793.pdf
Data publikacji:
2010
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
wody geotermalne
wykorzystanie energii geotermalnej
Polska
geothermal waters
using geothermal energy
Polska
Opis:
The area of Poland is characterized by heat flow values ranging from 20 to 90 mW/m2 and geothermal gradients - from 1 to 4°C/100 m. Thermal regime and geological conditions imply that the country possesses generally low-enthalpy resources belonging to the largest in Europe. Generally, reservoirs situated at 1 to 4 km depths are characterized by temperature varying from 30 to 130°C and TDS values from 0.1 to 300 g/dm3. The proven geothermal water reserves, evidenced on the basis of well flow tests, are estimated at several l/s up to 153 l/s. The best geothermal conditions are found in the Polish Lowlands and in Podhale Basin, the Inner Carpathians. Since 1992, eight geothermal heating plants have been brought on-line. The space-heating plants currently in operation in Poland include: four plants in: the Podhale region (Szymoszkowa and Antałówka plants in Zakopane, the plant at Bukowina Tatrzańska and the largest plant at Bańska Niżna) and four in the Polish Lowlands (Stargard Szczeciński and Pyrzyce plants in NW Poland, using water from Lower Jurassic reservoir, and Mszczonów and Uniejów plants in central Poland, using water from Lower Cretaceous reservoir). Each of these plants uses water of different type which results in differences in their mode of operation and utilization of geothermal water. Some of these are combined cycle plants which also have a gas turbine fired by natural gas to cover peak demand for heat (sometimes in large part) and and plants integrating absorption heat pumps AHP with gas boilers. Up to the present, no use of geothermal energy plants for other purposes than space heating was planned in Poland. However, similarly as in other countries, the attention begins to be focused on possibilities to build and operate geothermal binary plants run on water with temperature over 90°C water, that is water expected to be recoverable from depths 3-4 km and greater).
Źródło:
Przegląd Geologiczny; 2010, 58, 7; 580-588
0033-2151
Pojawia się w:
Przegląd Geologiczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal water - more than water!
Autorzy:
Witkowska, M.
Śmigielski, K. B.
Powiązania:
https://bibliotekanauki.pl/articles/2057992.pdf
Data publikacji:
2022
Wydawca:
Politechnika Łódzka. Wydawnictwo Politechniki Łódzkiej
Tematy:
cosmetics
thermal waters
health
dermocosmetics
geothermal waters
kosmetyki
wody termalne
zdrowie
dermokosmetyki
wody geotermalne
Opis:
The use of thermal waters both for external use and for consumption is presented. Nowadays, the use of ecological products of natural origin is promoted, allowing for a significant improvement in the psycho-physical condition of users. Research is carried out to create natural products that comprehensively improve not only the condition of the skin, but the entire body of the user. Thanks to the development of modern technologies used both in cosmetics and other industries, it is possible to effectively use the composition and properties of thermal waters.
Źródło:
Biotechnology and Food Science; 2022, 84, 1; 41--52
2084-0136
2299-6818
Pojawia się w:
Biotechnology and Food Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pilotowa instalacja odsalania wód geotermalnych w Polsce
The pilot of geothermal water desalination installation in Poland
Autorzy:
Tomaszewska, B.
Hołojuch, G.
Powiązania:
https://bibliotekanauki.pl/articles/183463.pdf
Data publikacji:
2011
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
wody geotermalne
odsalanie wody
bilans wodny
Polska
geothermal waters
water desalination
water balance
Polska
Opis:
Wstępne wyniki badań odsalania wód geotermalnych prowadzone w Laboratorium Geotermalnym Polskiej Akademii Nauk (IGSMiE PAN) pokazały, iż możliwe jest wytwarzanie wód pitnych z wód geotermalnych o podwyższonym zasoleniu. Istnieje wiele rozwiązań ideowych odsalania, jednakże głównym czynnikiem determinującym wdrożenie konkretnej technologii jest zawsze koszt odsalania. Zależy on od szeregu czynników, jakości wody surowej, rodzaju technologii i wielkości instalacji oraz kosztów energii. Technologie membranowe odsalania wód oraz metody hybrydowe, łączące technologie membranowe i termiczne, stosowane są na dużą skalę w wielu regionach świata do produkcji wody pitnej. Uznawane są też za dobrą pod względem technicznym i ekonomicznym metodę odsalania wód, głównie morskich. Pilotowe badania odsalania wód geotermalnych pokazują, iż technologie te mogą znaleźć zastosowanie w odsalaniu wód geotermalnych. Wykorzystanie wód geotermalnych do celów pitnych w skali przemysłowej będzie wymagało przede wszystkim lepszego i bardziej efektywnego ich schłodzenia - do temperatury poniżej 35°C. Optymalne wykorzystanie i zagospodarowanie wydobywanych wód geotermalnych umożliwiające zoptymalizowanie pracy systemu oraz poprawę ekonomicznej sfery funkcjonowania zakładów geotermalnych jest istotnym problemem w przypadku większości przedsięwzięć na terenie Polski i za granicą. Wykorzystanie schłodzonych wód do celów pitnych, zwłaszcza w instalacjach pracujących w systemie otwartym (bez zatłaczania schłodzonych wód do górotworu), może się przyczynić do kompleksowego ich wykorzystania, a jednocześnie decentralizacji produkcji wód pitnych. Prowadzone w IGSMiE PAN badania dotyczącą dwóch istotnych obszarów badawczych: geotermii (metodyka utylizacji schłodzonych wód) i hydrogeologii (gospodarka wodna).
The pilot geothermal water desalination installation in Poland was commissioned at the Geothermal Laboratory of the Mineral and Energy Economy Research Institute of the Polish Academy of Sciences (PAS MEERI). Laboratory is localised in Podhale region, in south-eastern Poland. Geothermal waters are extracted from carbonate formations of the Middle Eocene and from Middle Triassic limestones and dolomites. These exhibit relatively low mineralisation - 3 g/dm3. Their temperature at the well outlet ranges 90°C. Installation is supplied with water at a temperature of about 35°C. The capacity has been set at 1 m3/hour of desalinated water. The objective of geothermal water desalination will be to obtain water that meets the requirements stipulated in the regulation of the Minister of Health of 29 March 2007 (Journal of Laws of 2007, No. 61, item 417) concerning the quality of water intended for human consumption. The preliminary results from the geothermal water desalination study conducted at the PAS MEERI are optimistic. In order to validate the assumptions made in the context of industrial applications, further studies have to be conducted in accordance with the project plans. It is certain, however, that the utilization of geothermal water for drinking purposes on an industrial scale will require, first of all, better and more efficient water cooling. Optimum utilization of the thermal waters obtained is an important issue for most geothermal plant both in Poland and abroad. Efficient geothermal water management has one main goal: optimizing system operation and improving the economics of geothermal plant operation. Additionally, the use of cooled water for drinking purposes, particularly for open drain installations (without injecting cooled water into the formation) will contribute to the comprehensive utilization of geothermal water and the decentralization of drinking water production. Therefore the present study concerns two significant research areas: geothermics (cooled water utilization methods) and hydrogeology (water management).
Źródło:
Geologia / Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie; 2011, 37, 2; 313-322
0138-0974
Pojawia się w:
Geologia / Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Testowanie badawcze "miękkiego kasowania" w geotermalnych otworach chłonnych
Research testing of "soft acidizing" treatment in geothermal injection wells
Autorzy:
Bielec, B.
Kępińska, B.
Powiązania:
https://bibliotekanauki.pl/articles/394210.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
wody geotermalne
miękkie kwasowanie
indeks chłonności
geothermal waters
soft acidizing
injectivity index
Opis:
W trakcie eksploatacji złóż geotermalnych systemem otworów pracujących w "dublecie geotermalnym" występują często problemy związane z zatłaczaniem wody po odzysku energii lub wykorzystaniu jej do innych celów (rekreacja, balneoterapia). Jednym z takich problemów jest spadek chłonności na skutek procesów chemicznych oraz kolmatacji filtra i strefy okołofiltrowej. Filtr i część warstwy chłonnej w pobliżu filtra należą do najbardziej newralgicznych obszarów, w których zachodzą zjawiska mające decydujący wpływ na charakter pracy otworu chłonnego. W celu poprawy chłonności otworów ujmujących wodę geotermalną, przede wszystkim ze złóż w skałach węglanowych oraz piaskowcach o spoiwie węglanowym, stosuje się zazwyczaj zabieg kwasowania. Konwencjonalne kwasowanie wymaga jednak zazwyczaj użycia urządzenia wiertniczego, co czyni je dość kosztownym, stąd też stosowane jest głównie przy eksploatacji węglowodorów. Alternatywą dla konwencjonalnego kwasowania jest tzw. "miękkie kwasowanie" (ang. soft acidizing). W niniejszym artykule omówiono przebieg badawczych testów miękkiego kwasowania wykonanych w testowej instalacji geotermalnej. Badania w ramach projektu pn: "Opracowanie wytycznych projektowych poprawy chłonności skal zbiornikowych w związku z zatłaczaniem wód termalnych w polskich zakładach geotermalnych" przeprowadzi) zespół Pracowni Odnawialnych Źródeł Energii Instytutu Gospodarki Surowcami Mineralnymi i Energią PAN we współpracy z Geotermią Mazowiecką S.A. Do badań wykorzystano nieeksploatowane wcześniej otwory geotermalne Skierniewice GT-1 i Skierniewice GT-2. W trakcie prac badawczych wykonano łącznie osiem testów miękkiego kwasowania. W trakcie sześciu z nich ciecz kwasująca o ściśle dobranym składzie podawana była przez przewód zabiegowy (ang. coiled tubing) bezpośrednio nad strefę złożową w otworze Skierniewice GT-2 na głębokość 2765 m. Natomiast w czasie dwóch testów ciecz kwasującą podawano bezpośrednio do obiegu wody złożowej. W artykule opisano przebieg jednego wybranego testu. Szczegółowe wyniki wszystkich badan opisane zostały w pracach Bujakowskiego i in. (2011) oraz Kępińskiej, Bujakowskiego [red. nauk.] i in. (2011). Do głównych przyczyn spadku chłonności otworu Skierniewice GT-2 należy zaliczyć zjawiska korozji i wytrącania wtórnych substancji mineralnych. Z analizy zmienności parametrów hydrodynamicznych wynika, że zabiegi stymulacji metodą miękkiego kwasowania dla odwiertu i skał zbiornikowych w Skierniewicach udrażniały w pewnym zakresie odwiert i strefę przyodwiertową, powodując wzrost chłonności. Ich efekty były jednak mniejsze i mniej trwałe niż efekty wywołane ciągłą korozją orurowania odwiertu i wtórnym wytrącaniem substancji mineralnych z wody geotermalnej, która ma wysoką mineralizację (ponad 100 g/dm3).
During the exploitation of geothermal systems operating in the wells doublet scheme, problems are commonly encountered with water injection after energy extraction from geothermal water or its use for other purposes (recreation, spas). One such problem is the drop in injectivity due to chemical processes and clogging of the filter and near-filter zone. The filter and part of the injection near-filter layer are the most critical areas in which the occurring phenomena have a decisive influence on the performance of an injection well. Acid treatment is the procedure generally used to improve the injectivity of wells exploiting geothermal water primarily from carbonate rocks and sandstones with carbonate binders. Conventional acid, however, usually requires the use of drilling equipment, which makes it quite expensive. It is used mainly in the exploitation of hydrocarbons. An alternative to conventional acid treatment is so-called "soft acidizing". This article discusses the research process of soft acidizing treatment tests performed on a test geothermal installation. Research done under the project entitled: "Development of design guidelines to improve injectivity of reservoir rocks in relation to injection of geothermal waters in Polish geothermal installations" was conducted by a team from the Mineral and Energy Economy Research Institute of the Polish Academy of Sciences in collaboration with the Geotermia Mazowiecka S.A. During the project, previously unexploited geothermal wells, Skierniewice GT-1 and Skierniewice GT-2, were used. In total, eight tests of soft acidizing treatment were carried out during the research. During six of the tests acidizing fluid of a closely matched composition was injected by a coiled tubing just above the reservoir zone in the Skierniewice GT-2 well to a depth of 2,765 meters. During two other tests acidizing fluid was added directly into the geothermal water stream at the wellhead. This article describes one of the selected tests. The detailed results of all tests are described in the works by Bujakowski et al. (2011) and Kępińska, Bujakowski [sc. eds.] et al. (2011). The main reasons for the drop in injectivity of the Skierniewice GT-2 well include corrosion and precipitation of secondary minerals. These processes depend, among other things, on the flow rate and duration of injection of geothermal water. The analysis of the level of changes in the hydrodynamic parameters shows that stimulation procedures using a soft acidizing treatment for borehole and reservoir rocks in Skierniewice increased to some extent the injectivities of borehole and near-borehole zones. Their effects, however, were smaller and less persistent than the effects of the continuous well casing's corrosion and precipitation of secondary minerals from geothermal water (which has a high mineralization of ca. 110 g/dm3).
Źródło:
Zeszyty Naukowe Instytutu Gospodarki Surowcami Mineralnymi i Energią PAN; 2012, 82; 71-87
2080-0819
Pojawia się w:
Zeszyty Naukowe Instytutu Gospodarki Surowcami Mineralnymi i Energią PAN
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Possibilities of using the energy potential of geothermal waters in the case of Poland and Ukraine
Autorzy:
Lis, Anna
Savchenko, Olena
Powiązania:
https://bibliotekanauki.pl/articles/31342620.pdf
Data publikacji:
2022
Wydawca:
Politechnika Częstochowska
Tematy:
geothermal energy
geothermal water
geothermal installation
energia geotermalna
wody geotermalne
instalacja geotermalna
Opis:
The development of energy based on RES is an important element of the policy of sustainable development and maintaining energy security. The difficult situation in the energy sector is turning more and more countries towards alternative energy sources. The feasibility of obtaining energy from renewable sources is linked primarily to the resources that are also economical. The main advantage of geothermal waters is that they can be used to produce heat or electricity, regardless of the time of day or climatic conditions. Data from geological research allows us to conclude that both Ukraine and Poland have favorable conditions for the use of energy from low and medium temperature geothermal waters. Ukraine is also turning to the possibility of using geothermal energy to produce electricity. Examples highlighting the possibility of using the energy potential of geothermal waters in the Lviv region and the Czestochowa poviat were presented.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2022, 11; 181-194
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamics of clogging processes in injection wells used to pump highly mineralized thermal waters into the sandstone structures lying under the Polish Lowlands
Dynamika kolmatacji otworu chłonnego przy zatłaczaniu wysoko zmineralizowanych wód termalnych w strukturach piaskowcowych na Niżu Polskim
Autorzy:
Tomaszewska, B.
Pająk, L.
Powiązania:
https://bibliotekanauki.pl/articles/204642.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wody geotermalne
zatłaczanie wody
osadzanie minerałów
indeks chłonności
geothermal waters
injection well
sedminetation
mineral deposition
Opis:
When identifying the conditions required for the sustainable and long-term exploitation of geothermal resources it is very important to assess the dynamics of processes linked to the formation, migration and deposition of particles in geothermal systems. Such particles often cause clogging and damage to the boreholes and source reservoirs. Solid particles: products of corrosion processes, secondary precipitation from geothermal water or particles from the rock formations holding the source reservoir, may settle in the surface installations and lead to clogging of the injection wells. The paper proposes a mathematical model for changes in the absorbance index and the water injection pressure required over time. This was determined from the operating conditions for a model system consisting of a doublet of geothermal wells (extraction and injection well) and using the water occurring in Liassic sandstone structures in the Polish Lowland. Calculations were based on real data and conditions found in the Skierniewice GT-2 source reservoir intake. The main product of secondary mineral precipitation is calcium carbonate in the form of aragonite and calcite. It has been demonstrated that clogging of the active zone causes a particularly high surge in injection pressure during the fi rst 24 hours of pumping. In subsequent hours, pressure increases are close to linear and gradually grow to a level of ~2.2 MPa after 120 hours. The absorbance index decreases at a particularly fast rate during the fi rst six hours (Figure 4). Over the period of time analysed, its value decreases from over 42 to approximately 18 m3/h/MPa after 120 hours from initiation of the injection. These estimated results have been confi rmed in practice by real-life investigation of an injection well. The absorbance index recorded during the hydrodynamic tests decreased to approximately 20 m3/h/MPa after 120 hours.
Ocena dynamiki procesów związanych z powstawaniem, migracją i deponowaniem cząstek stałych w systemach geotermalnych, powodujących często kolmatację i uszkodzenia otworów i złóż, jest bardzo istotna dla identyfi kacji warunków ich stabilnej i długotrwałej eksploatacji. Cząstki stałe: produkty korozji, wtórne substancje wytrącane z wody geotermalnej czy też cząstki skał zbiornikowych, mogą osadzać się w instalacji powierzchniowej oraz prowadzić do kolmatacji otworów chłonnych. W pracy zaproponowano matematyczny opis zmian w czasie indeksu chłonności oraz wymaganego ciśnienia zatłaczania wody w zamodelowanych warunkach eksploatacji dubletem otworów (otwór eksploatacyjny – chłonny) wód występujących w obrębie piaskowcowych struktur liasowych na Niżu Polskim. Dla przeprowadzenia obliczeń posłużono się rzeczywistymi danymi dotyczącymi warunków ujęcia złoża otworem Skierniewice GT-2. Podstawowym produktem wytracania wtórnych substancji mineralnych z wody geotermalnej badanego systemu jest węglan wapnia w formie aragonitu i kalcytu. Wykazano, iż w skutek kolmatacji strefy czynnej szczególnie gwałtownie ciśnienie zatłaczania rośnie w pierwszej dobie. W kolejnych godzinach, przyrost ciśnienia ma charakter zbliżony do liniowego i sukcesywnie rośnie, osiągając wartość ~2,2 MPa po 120 godzinach. Indeks chłonności spada, szczególnie wyraźnie w okresie pierwszych 6 godzin (Fig. 4). W rozpatrywanym przedziale czasu jego wartość maleje z pond 42 do ok. 18 m3/h/MPa po 120 godzinach od rozpoczęcia zatłaczania. Wyniki prognozy znalazły potwierdzenie w trakcie realizacji rzeczywistych badań w otworze chłonnym. Indeks chłonności w trakcie wykonywania testów hydrodynamicznych po czasie 120 godzin spadł do ok. 20 m3/h/MPa.
Źródło:
Archives of Environmental Protection; 2012, 38, 3; 105-117
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies