Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "woda ciepla" wg kryterium: Temat


Tytuł:
Technical and Economic Analysis of The Use of Heat Pumps in a Public Facility
Autorzy:
Wiekiera, Radosław
Powiązania:
https://bibliotekanauki.pl/articles/27314842.pdf
Data publikacji:
2022
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
air-water heat pump
ground-water heat pump
heat pumps
RES
pompy ciepła powietrze-woda
pompa ciepła grunt-woda
pompy ciepła
OZE
Opis:
A heat pump uses natural energy from renewable sources such as air, ground or water. The pump, acquiring thermal energy from the environment (75%) and using electricity (25%), supplies it to the heated object. A heat pump-based system consists of a ground heat source (heat is taken from it), a heat pump unit and an upper heat source (heat is transferred to it). The refrigerant transfers heat from the lower heat source to the upper heat source. The paper discusses types of heat pumps in terms of the use of the lower heat source. A technical and economic analysis was carried out on the basis of two types of heat pump: air-to-water and ground-to-water A comparative analysis of the results obtained results will allow a real assessment of the system’s functioning.
Źródło:
Civil and Environmental Engineering Reports; 2022, 32, 4; 376--388
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation into the thermal protection of building enclosing structures in the case of emergency heat supply
Autorzy:
Rafalskaya, Tatyana
Powiązania:
https://bibliotekanauki.pl/articles/2065650.pdf
Data publikacji:
2021
Wydawca:
Politechnika Częstochowska
Tematy:
ograniczona podaż ciepła
ogrzewanie
ciepła woda
akumulacja ciepła
limited heat supply
heating
hot water supply system
heat accumulation
Opis:
In case of emergency situations in heat supply systems, the water temperature in the supply line of the system decreases. It is necessary to determine the allowable operational duration of the heating system in case there is an accident, taking into account heat accumulation in exterior building envelopes and the variable flow of water in the hot water supply system. Operational modes of the heat supply system during emergency heat release from the CHP are studied. Factors affecting the thermal regime of buildings with external fences of various levels of heat accumulation are considered. A method is developed for calculating the cooling rate of the inner surface of the outer fence and the temperature on this surface at a given time. Calculated dependences are obtained for determining the permissible operating time of the heat supply system with a limited heat supply.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2021, 10, 1; 87--96
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena techniczno-ekonomiczna systemów grzewczych w budynku o niemal zerowym zużyciu energii współpracujących z mikroinstalacją fotowoltaiczną
Technical and economic evaluation of heating systems in a nearly zero energy building cooperating with a photovoltaic microinstalation
Autorzy:
Szul, Tomasz
Kokoszka, Stanisław
Powiązania:
https://bibliotekanauki.pl/articles/946857.pdf
Data publikacji:
2020-06-30
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Maszyn Rolniczych
Tematy:
zużycie energii końcowej w budynku
budynek o niemal zerowym zużyciu energii
pompy ciepła typu powietrze/woda
pa-nele grzewcze
mikroinstalacja PV
analiza ekonomiczna
koszty cyklu życia LCC
final energy consumption in a building
nearly zero energy building
air/water heat pumps
heating panels
PV microin-stallation
economic analysis
LCC life cycle costs
Opis:
Dla przykładowego budynku mieszkalnego jednorodzinnego obliczono zapotrzebowanie na moc i sezonowe zużycie energii do ogrzewania i przygotowania ciepłej wody użytkowej, określono również w oparciu o zestawienia statystyczne wielkość zużycia energii elektrycznej na cele bytowe (oświetlenie, AGD, RTV, itp.). Na tej podstawie dobrano moc i określono roczną wielkość produkcji przez mikroinstalację fotowoltaiczną pracującą w systemie ON-GIRD w ramach przepisów do-tyczących prosumentów zawartych w ustawie o OZE. Następnie przeprowadzono analizę ekonomiczną zgodnie z metodą opartą na kosztach cyklu życia LCC. Jako poziom odniesienia przyjęto budynek, w którym ogrzewanie i przygotowanie ciepłej wody użytkowej odbywa się za pomocą kotła gazowego kondensacyjnego, natomiast instalacja PV służy do pokrycia zapotrzebowania na energię elektryczną w budynku. Do analizy porównawczej przyjęto dwa systemy grzewcze, tj. pompę ciepła typu powietrze/woda oraz panele grzewcze. W tym przypadku instalacja PV miała pokryć wszystkie potrzeby energetyczne w budynku. W celu określenia zasadności montażu instalacji fotowoltaicznej służącej do pokrycia potrzeb energetycznych budynku dla poszczególnych wariantów, wykonano analizę ekonomiczną w oparciu o koszty cyklu życia LCC. Wyniki analizy wskazały, że lepszym wyborem dla inwestora będzie, jeżeli zdecyduje się na montaż systemu ogrzewania opartego na panelach grzewczych, m.in. ze względu na najkrótszy okres zwrotu nakładów inwestycyjnych.
For an exemplary single-family residential building, the power demand and seasonal energy consumption for heating and domestic hot water preparation were calculated, and the amount of electricity consumption for domestic purposes was also determined on the basis of statistical summaries. On this basis, the power was selected and the annual production volume of the photovoltaic microinstallation operating in the ON-GIRD system was determined under the Prospectus Reg-ulations of the Renewable Energy Sources Act. An economic analysis was then carried out based on methods based on LCC life cycle costs. A building where heating and domestic hot water preparation is carried out by means of a condens-ing gas boiler, while a photovoltaic installation serves to cover the electricity demand of the building was taken as a reference. Two heating systems were used for the comparison analysis, i.e. the air-water heat pump and the heating panels. In this case, the PV installation was to cover all energy needs in the building. In order to determine the validity of in-stalling a photovoltaic installation to cover the energy needs of the building for each variant, an economic analysis based on LCC life cycle costs was performed. The results of the analysis showed that a better choice for the investor will be if he decides to install a heating system based on heating panels, among others because of the shortest period of return on investment.
Źródło:
Technika Rolnicza Ogrodnicza Leśna; 2020, 1; 13-17
1732-1719
2719-4221
Pojawia się w:
Technika Rolnicza Ogrodnicza Leśna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Waste Heat Recovery by Electric Heat Pump from Exhausted Ventilating Air for Domestic Hot Water in Multi-Family Residential Buildings
Odzysk ciepła odpadowego za pomocą elektrycznej pompy ciepła z wywiewanego powietrza wentylacyjnego do systemu ciepłej wody użytkowej w wielorodzinnych budynkach mieszkalnych
Autorzy:
Cepiński, Wojciech
Kowalski, Piotr
Szałański, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/1811652.pdf
Data publikacji:
2020
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
air-to-water electric heat pump
waste heat recovery
heat recovery in ventilation
domestic hot water
TRNSYS
sprężarkowa pompa ciepła powietrze/woda
odzysk ciepła odpadowego
odzysk ciepła z wentylacji
woda ciepła użytkowa
Opis:
The article discusses the possibility of recovering waste heat from the exhaust air from the ventilation system of multi-family residential buildings. A system of waste heat recovery from the extracted air with an electric heat pump was proposed for the preparation of domestic hot water (DHW). The proposed system has been analysed in TRNSYS 17 software for exemplary multi-family residential building. The influence of exhaust air humidity and heat pump outlet temperature on the energy effect was analysed. For the analysed case and the Polish conditions of electricity production, a possible reduction of the final energy amount for DHW preparation (EKW) by 35.1% and primary energy consumption (EPW) by 9.1% was determined in comparison with the use of a gas condensing boiler only. The factors influencing the energy effect of the system for the recovery of waste heat from the exhaust air were indicated. The authors specified directions of further research aimed at determining how to recover available waste heat from the exhaust air with lower energy expenditure and for which installations in the building they should be used.
W artykule podjęto temat możliwości odzyskania ciepła odpadowego z powietrza wywiewanego z systemu wentylacyjnego budynków wielorodzinnych mieszkalnych. Zaproponowano system odzysku ciepła odpadowego z powietrza wywiewanego elektryczną pompą ciepła dla potrzeb przygotowania ciepłej wody. Zaproponowany system przeanalizowano w oprogramowaniu TRNSYS 17 dla przykładowego budynku wielorodzinnego. Przedstawiono wpływ wilgotności względnej powietrza wywiewanego i temperatury zasilania pompy ciepłej na efekt energetyczny. Dla analizowanego przypadku i polskich warunków produkcji energii elektrycznej, wyznaczono możliwe zmniejszenie zapotrzebowania energii końcowej na przygotowanie ciepłej wody użytkowej (EKW) o 35,1% i energii pierwotnej (EPW) o 9,1% w porównaniu z zastosowaniem tylko gazowego kotła kondensacyjnego. Wskazano czynniki wpływające na efekt energetyczny systemu do odzysku ciepła odpadowego z powietrza wywiewanego. Autorzy podali kierunki dalszych badań zmierzających do określenia jak odzyskać dostępne ciepło odpadowe z wywiewu przy mniejszym nakładzie energetycznym i do jakich instalacji w budynku je wykorzystać.
Źródło:
Rocznik Ochrona Środowiska; 2020, Tom 22, cz. 2; 940-958
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Air–water heat pump applied as water boiler in singlefamily house, coefficient of performance analysis under the real conditions
Autorzy:
Lisowska-Lis, A.
Leszczyński, R.
Powiązania:
https://bibliotekanauki.pl/articles/93094.pdf
Data publikacji:
2018
Wydawca:
Państwowa Wyższa Szkoła Zawodowa w Tarnowie
Tematy:
heat pump
air-water
coefficient of performance
COP
pompa ciepła
powietrze-woda
współczynnik wydajności
Opis:
The subject of the research was an air-water heat pump, model PCUW 2.5kW from HEWALEX, installed in a single-family house. The pump is only used for heating water. The research was carried out from 25-08-2017 to 18-09-2017 in the village of Zborowice, in Malopolska region, Poland. The data were recorded from the heat pump system: temperature of the lower heat source (external air), temperature of the upper heat source (water temperature in the tank), time of heat pump was calculated during the analysed cycle of work and electrical energy consumption. The Coefficient Of Performance (COP) of the analysed air-water heat pump was determined. The analysis of the results was carried out using the MATLAB and EXCEL statistical tools. The correlation between COP coefficient and external air temperature is strong: 0.67.
Źródło:
Science, Technology and Innovation; 2018, 3, 2; 58-61
2544-9125
Pojawia się w:
Science, Technology and Innovation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Opłacalność ekonomiczna zmiany wielkości powierzchni kolektorów słonecznych płaskich w instalacji c.w.u. budynku jednorodzinnego – studium przypadku
The economic profitability of the changing size of solar collectors surface in the case study of the household domestic hot water installation
Autorzy:
Olczak, P.
Kryzia, D.
Augustyn, A.
Olek, M.
Powiązania:
https://bibliotekanauki.pl/articles/394291.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
ciepła woda użytkowa (c.w.u.)
kolektory słoneczne
promieniowanie słoneczne
opłacalność ekonomiczna
NPV
Monte Carlo
domestic hot water (DHW)
solar collectors
solar radiation
economic profitability
Opis:
Kolektory słoneczne są głównymi elementami solarnych systemów grzewczych. Praca tych urządzeń polega na konwersji energii promieniowania słonecznego na ciepło czynnika roboczego. Czynnikiem tym może być zarówno ciecz (glikol lub woda), jak i gaz (powietrze). Ze względu na konstrukcję wyróżnia się kolektory płaskie, próżniowe, próżniowo-rurowe i skupiające. Kolektory płaskie są stosowane przede wszystkim w budynkach, w których potrzeby cieplne są niskie lub średnie, czyli na przykład w gospodarstwach domowych. Rozwój kolektorów został ukierunkowany na zwiększenia wydajności oraz poprawy efektywności ekonomicznej inwestycji. W artykule oceniono wpływ zmiany powierzchni płaskich kolektorów słonecznych na opłacalność ekonomiczną inwestycji. Do analizy wytypowano dom jednorodzinny, zlokalizowany w województwie małopolskim, w którym instalacja przygotowania ciepłej wody użytkowej została rozbudowana o system solarny. System ten składa się z płaskich kolektorów, o łącznej powierzchni absorberów 5,61 m2. Jako czynnik roboczy w instalacji stosowany jest glikol. W celu poprawy efektu ekonomicznego zaproponowano zwiększenie powierzchni absorberów. Na podstawie trzyletnich pomiarów nasłonecznienia oraz efektów cieplnych instalacji, stworzono model ekonomiczny służący do oceny opłacalności zwiększenia powierzchni kolektorów słonecznych. Obliczenia z użyciem modelu promieniowania HDKR wykonano w środowisku Matlab dla lokalizacji Tarnów (najbliższej instalacji). Ponadto na podstawie rzeczywistych pomiarów z tej instalacji, odzwierciedlających wpływ wielu niemierzalnych czynników na efektywność przetwarzania energii słonecznej, wykonano symulacje efektu ekonomicznego dla różnych wielkości zapotrzebowania na ciepło. Otrzymane wyniki uogólniono, co daje możliwość ich wykorzystania w procesie doboru wielkości powierzchni kolektorów w przypadku podobnych instalacji.
Solar collectors are the main components of the solar heating systems. This devices convert radiation from the sun into the heat of distribution medium. The medium can be either (water, glycol) or gas (air). Two types of solar panels can be distinguished on the basis of the construction criterion: flat plate collectors and evacuated tube collectors. Solar collectors development progresses towards improving their efficiency and economic profitability. Flat plate collectors are popular for low and medium heating applications, i.e. in households. In this paper, flat plate collectors with glycol as a distribution medium are investigated. The authors evaluate the impact of changing the size of the solar collectors on the heating economic profitability. A detached house, located in the Malopolskie Province was selected for the analysis. The house was fitted with domestic hot water installation which was extended with the solar system. At present, the collector area amounts to 5.61 m2. In order to improve the economic effect, the authors propose to increase their area. The radiation from the sun, sun exposure and thermal results were collected and calculated for three years. The authors prepared an economic model on the basis of the collected data. This model was created to assess the economic effect in relation to increasing the collector area. Calculations were made with the HDKR radiation model using Matlab software. The authors chose Tarnow as location because the city is the nearest to the tested installation. In addition, the authors created a simulation that allowed the economic effect for different detached houses with different heat demands to be assessed. By using real data an impact of many non-measurable factors on the efficiency of solar energy conversion could be taken into account in the simulation. The obtained results have been generalized and thus can be applied in a similar installation during the process of choosing an appropriate collector area size.
Źródło:
Zeszyty Naukowe Instytutu Gospodarki Surowcami Mineralnymi i Energią PAN; 2018, 102; 77-90
2080-0819
Pojawia się w:
Zeszyty Naukowe Instytutu Gospodarki Surowcami Mineralnymi i Energią PAN
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Technical and economic evaluation of a heating system based on air-to-water heat pumps with photovoltaic - micro-installation within the Prosument program
Ocena techniczno-ekonomiczna systemu grzewczego opartego na pompach ciepła typu powietrze woda współpracującego z mikroinstalacją fotowoltaiczną w ramach programu Prosument
Autorzy:
Szul, T.
Powiązania:
https://bibliotekanauki.pl/articles/334685.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Maszyn Rolniczych
Tematy:
final energy consumption
building
air-water heat pump
PV micro-installation
Prosumer program
economic analysis
zużycie energii końcowej
budynek
pompa ciepła typu powietrze-woda
mikroinstalacja PV
program Prosument
analiza ekonomiczna
Opis:
For an exemplary single-family residential building, final energy consumption for heating and domestic hot water preparation was calculated using an air / water heat pump, consumption of electricity for household purposes (lighting, household appliances, RTV, etc.) was also calculated as based on statistical summaries. On this basis, power was selected and the annual production volume was determined by a photovoltaic micro-installation working in the ON-GIRD system pursuant to prosumer regulations contained in the Act on Renewable Energy. Then, an economic analysis was carried out basing on such static and dynamic methods as SPBT, PBP, NPV, IRR and CCE. The calculations were made for two variants, i.e.: the investment costs of the system are borne entirely by the investor, or the installation is purchased within the "EKOkredyt Prosument II" NFEP&WM program. As a result of the calculations, it was found that the investment in PV microinstallation will be profitable only if the support instruments offered by the NFEP&WM program are used. If the investor uses co-financing, the investment will pay back within 16 years at the latest and if he wants to invest his own funds, the waiting period for the return on investments can be extended to up to 21 years, which, given the twenty-five year period of operation, can turn out to be the risk that the funds invested can never be returned.
Dla przykładowego budynku mieszkalnego jednorodzinnego obliczono zużycie energii końcowej do ogrzewania i przygotowania ciepłej wody użytkowej za pomocą pompy ciepła typu powietrze/woda. Określono również w oparciu o zestawienia statystyczne wielkość zużycia energii elektrycznej na cele bytowe (oświetlenie, AGD, RTV, itp.) Na tej podstawie dobrano moc i określono roczną wielkość produkcji przez mikroinstalację fotowoltaiczną pracującą w systemie ON-GIRD w ramach przepisów dotyczących prosumentów zawartych w ustawie o OZE. Następnie przeprowadzono analizę ekonomiczną w oparciu o metody statyczne i dynamiczne takie jak: SPBT, PBP, NPV, IRR oraz CCE. Obliczenia wykonano dla dwóch wariantów, tj.: koszty inwestycyjne systemu ponoszone są w całości przez inwestora lub instalacja jest zakupiona w ramach programu NFOŚiGW „EKOkredyt Prosument II”. W wyniku przeprowadzonych obliczeń stwierdzono, że inwestycja w mikroinstalację PV będzie opłacalna jedynie w przypadku skorzystania z instrumentów wsparcia oferowanych przez program NFOŚiGW. Jeżeli inwestor skorzysta z dofinansowania to inwestycja zwróci się najpóźniej w ciągu 16 lat, natomiast jeżeli będzie chciał zainwestować środki własne okres oczekiwania na zwrot nakładów może wydłużyć się nawet do 21 lat, co przy zakładanym dwudziestopięcioletnim okresie eksploatacji może okazać się, że inwestycja ta będzie niosła za sobą ryzyko, iż zainwestowane środki mogą się nie zwrócić.
Źródło:
Journal of Research and Applications in Agricultural Engineering; 2018, 63, 4; 197-202
1642-686X
2719-423X
Pojawia się w:
Journal of Research and Applications in Agricultural Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wybrane przykłady zastosowania zieleni i wody jako naturalnych elementów przestrzeni poprawiających warunki lokalnych klimatów
Selected examples of the use of greenery and water as a natural space elements improving local climates conditions
Autorzy:
Klimowicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/344707.pdf
Data publikacji:
2018
Wydawca:
Politechnika Krakowska im. Tadeusza Kościuszki. Wydział Architektury. Katedra Kształtowania Środowiska Mieszkaniowego
Tematy:
zieleń w architekturze
miejska wyspa ciepła
mikroklimat
woda w architekturze
greenery in architecture
water in architecture
Urban Heat Island
microclimate
Opis:
Obecnie w prężnie rozwijających się miastach, obserwowany jest problem tzw. „Miejskiej Wyspy Ciepła”. Problem przegrzewających się przestrzeni zurbanizowanych wymusił niejako stosowanie rozwiązań służących poprawie lokalnych mikroklimatów. W rozwiązaniach urbanistycznych i architektonicznych XXI wieku zarówno zieleń, jak i woda coraz częściej wpisuje się na stałe w nowoczesne rozwiązania. Mają one istotny wpływ na projekty zwłaszcza te, które ubiegają się o certyfikaty energooszczędności oraz służą poprawie warunków życia lokalnych społeczności. W wielu krajach, zastosowanie tych rozwiązań wiąże się też z kulturą i tradycją. Na przykład w Syrii wewnętrzne ogrody z elementami zbiorników wodnych na stałe wpisane są w historyczne rozwiązania. We Włoszech czy Francji, też trudno sobie wyobrazić przestrzenie miejskie czy obiekty bez zastosowania zieleni i wody. Zmieniający się klimat na Ziemi spowodował, że i w Polsce coraz częściej stosuje zieleń i wodę w nowoczesnych rozwiązaniach.
In many urbanized and developing cities we are observing the overheating of urban spaces commonly referred to as the Urban Heat Island effect. This pattern is forcing the development of innovative urban and architectural microclimate based solutions using both greenery and water to meet the energy efficiency certifications and to improve the living conditions of the local communities. The use of greenery and water elements in the design of cities and other public spaces has been commonplace in many civilizations and often associated with local cultures and traditions. As an example internal gardens using water reservoirs are used commonly in historic buildings and spaces in Syria. In Italy or France, it is difficult to imagine public places without the use of greenery and water. As a reaction to the mounting evidence of the effects of the Earth’s climate change, Polish designers are called to consider the use of greenery and water as part of present urban and architecture solutions.
Źródło:
Środowisko Mieszkaniowe; 2018, 24; 26-33
1731-2442
2543-8700
Pojawia się w:
Środowisko Mieszkaniowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Теплоснабжения на основе термотрансформированной энергии стабилизирующего охлаждения печи и переохлаждения теплоносителя низкопотенциальных источников
Heat supply based on thermotransformed energy of stabilizing cooling of the furnace and supercooling of coolant of low–potential sources
Autorzy:
Petrash, V.D.
Geraskina, E.A.
Danicenko, N.V.
Chernysheva, I.V.
Powiązania:
https://bibliotekanauki.pl/articles/2067774.pdf
Data publikacji:
2018
Wydawca:
Politechnika Częstochowska
Tematy:
heating and hot water supply
system efficiency
coolant flow rate
conversion rate
ogrzewanie
wydajność systemu
współczynnik konwersji
ciepła woda
Opis:
В статье представлены исследования совместной работы отопления и горячего водоснабжения. Установлено, что эффективность системы возрастает с увеличением расхода теплоносителя на горячее водоснабжение, а также при снижении температуры теплоносителя в системе отопления. Аналитическим способом установлено для системы с доохлаждением рациональное сочетание исходных и режимных условий, которое в системе анализируемой структуры обеспечивает оптималное значение коэффициента преобразования.
The article presents a study of the joint work of heating and hot water. It has been established that the efficiency of the system increases with an increase in the coolant flow rate for hot water supply, as well as with a decrease in the coolant temperature in the heating system. Analytically, a rational combination of initial and regime conditions is established for a system with subcooling, which in the system of the analyzed structure provides the optimal value of the conversion coefficient.
Źródło:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo; 2018, 24 (174); 280-284
0860-7214
Pojawia się w:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental set - up to research inductive heating of domestic hot water
Autorzy:
Peplińska-Matysiak, K.
Pecolt, S.
Krzyżyński, T.
Powiązania:
https://bibliotekanauki.pl/articles/118538.pdf
Data publikacji:
2016
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
inductive
domestic hot water
heating systems
temperature sensors
badania indukcyjne
ciepła woda użytkowa
systemy grzewcze
czujniki temperatury
Opis:
The article discusses experimental set – up to research inductive heating of domestic hot water. The article presents parts which contain test stand include: water tank, measuring, heating and acquisition systems. Each part is described with important parameters. The paper further presents result of research in two setups – with the stirring of water by pump and without the stirring of water.
Artykuł przedstawia stanowisko pomiarowe do badania indukcyjnego podgrzewacza wody użytkowej o pojemności 50 litrów. Szczegółowo opisano elementy stanowiska pomiarowego do automatycznej akwizycji danych wraz z aplikacją zbudowaną w LabView. Omówiono parametry zastosowanych czujników i przetworników. W drugiej części artykułu przedstawiono wyniki badań zebrane na stanowisku badawczym podczas dwóch procesów – z mieszaniem wody w zbiorniku w obiegu zamkniętym i bez mieszania wody, dzięki czemu można było zaobserwować uwarstwienie temperaturowe wody w bojlerze.
Źródło:
Zeszyty Naukowe Wydziału Elektroniki i Informatyki Politechniki Koszalińskiej; 2016, 9; 67-76
1897-7421
Pojawia się w:
Zeszyty Naukowe Wydziału Elektroniki i Informatyki Politechniki Koszalińskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Storage water heaters design in apartment buildings
Projektowanie pojemnościowych podgrzewaczy wody w budynkach mieszkalnych
Autorzy:
Cermanova, Z.
Perackova, J.
Jagerska, L.
Powiązania:
https://bibliotekanauki.pl/articles/2065459.pdf
Data publikacji:
2016
Wydawca:
Politechnika Częstochowska
Tematy:
storage water heaters
domestic hot water
apartment buildings
design methodology
pojemnościowy podgrzewacz wody
ciepła woda użytkowa
budynki mieszkalne
metodologia projektowania
Opis:
The paper is focused on the optimization and developing of design methodologies of storage water heaters for apartment buildings determined by experimental measurements in the different apartment buildings in Slovakia. The hourly maximum consumption of hot water in different apartment houses, the average hourly maximum of domestic hot water requirements determined for one person and energy balance of the domestic hot water system were found out by experimental measurements. Design methodology is composed of two steps. The first step is volume design of storage water heater and the second step is its power requirement design. This design methodology seems to be more accurate than the methodology of domestic hot water storage design in the Slovak Technical Standard currently in force. The proposed methodology better reflects the current demands of domestic hot water preparation in apartment buildings in Slovakia.
Przedstawiono optymalizację i rozwój metodologii projektowania pojemnościowych podgrzewaczy wody dla budynków mieszkalnych na podstawie pomiarów przeprowadzonych w różnych budynkach mieszkalnych na Słowacji. Na podstawie pomiarów określono godzinowy maksymalny pobór ciepłej wody w różnych budynkach, średnie maksymalne godzinowe zapotrzebowanie na ciepłą wodę dla jednej osoby i bilans energetyczny dla systemu ciepłej wody użytkowej. Metodologia składa się z dwóch etapów. Pierwszy obejmuje projekt, a drugi obliczenie zapotrzebowania na moc cieplną. Proponowana metoda lepiej odzwierciedla aktualne wymagania związane z przygotowaniem ciepłej wody użytkowej w budynkach mieszkalnych na Słowacji.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2016, 2 (18); 21--28
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiz suscestvuuscich ustrojstw i sistem otbora nizkopotencial’noj teploty stocnych vod v sisteme kanalizacii
Analysis of existing devices and systems for utilization of low-grade heat waste sewage water
Autorzy:
Obidnyk, A.
Malkin, E.
Jacenko, A.
Powiązania:
https://bibliotekanauki.pl/articles/2065301.pdf
Data publikacji:
2015
Wydawca:
Politechnika Częstochowska
Tematy:
ścieki
ciepła woda
pompy ciepła
odzysk ciepła
waste water
hot water
low grade heat
heat pumps
heat recovery
Opis:
Odnim iz vozmoznych istocnikov nizkopotencial’noj teploty dla sistem teplosnabzenia mogut byt’ stocnye vody sistem kanalizacii. V stat’e vypolnen obzor i sravnenie suscestvuuscich ustrojstw i sistem dla utilizacii teploty stocnych vod vo vnutrennich i naruznych sistemach kanalizacii, v castnosti predstavleny preimuscestva i nedostatki ispol’zovania ustrojstv i sistem.
One possible source of low-grade heat for heating systems is sewerage waste water. The article presents the review and the comparison of existing devices and systems for heat recovery of waste water in the interior and exterior sewer systems, in particular, the advantages and disadvantages of the use of devices and systems.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2015, 1 (15); 143--151
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka energetyczna budynków wiejskich powstałych przed rokiem 1918
Energy performance of buildings in rural areas built before 1918
Autorzy:
Szul, T.
Powiązania:
https://bibliotekanauki.pl/articles/884469.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Maszyn Rolniczych
Tematy:
budynki wiejskie
budynki powstale przed rokiem 1918
charakterystyka energetyczna
wspolczynnik przenikania ciepla
zapotrzebowanie na energie
ogrzewanie
woda ciepla uzytkowa
Źródło:
Technika Rolnicza Ogrodnicza Leśna; 2015, 3
1732-1719
2719-4221
Pojawia się w:
Technika Rolnicza Ogrodnicza Leśna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efektywność wykorzystania energii pierwotnej do przygotowania ciepłej wody użytkowej w lokalnej kotłowni osiedlowej
PRIMARY ENERGY CONSUMPTION FOR PREPARATION OF HOT WATER IN BOILER ROOM
Autorzy:
Bartnicki, Grzegorz
Chmielewska, Agnieszka
Powiązania:
https://bibliotekanauki.pl/chapters/2231940.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
ciepła woda użytkowa
zmienność zużycia paliwa
efektywność energetyczna
Opis:
W artykule przedstawione zostały wyniki badań zużycia mediów prowadzonych w istniejącym systemie grzewczym, w którym od kilku lat prowadzone są badania dotyczące problematyki efektywności energetycznej systemów grzewczych oraz funkcjonowania współczesnych, lokalnych źródeł ciepła. Na podstawie danych pomiarowych oszacowano udział ciepła na cele przygotowania ciepłej wody użytkowej w mieszkaniach, który jest zdecydowanie większy niż podawany w literaturze. Określono również zmienność zużycia paliwa i ciepłej wody użytkowej w cyklu rocznym i miesięcznym. Na tej podstawie oszacowano ilość zużytego paliwa na cele przygotowania ciepłej wody użytkowej w ciągu roku.
The paper presents the results of the analysis of energy consumption in residential buildings based on an example of a housing estate in Wroclaw. Data were obtained from monthly readings of heatmeters, water metres, and gas consumption of two boilers houses. Based on the measured data was estimated share of heat for domestic hot water purposes and monthly variation of fuel and heat consumption.
Źródło:
Interdyscyplinarne zagadnienia w inżynierii i ochronie środowiska 6; 5-12
9788374938976
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal performance of energy storage vessel
Autorzy:
Jurigova, M.
Minarova, M.
Chmurny, I.
Powiązania:
https://bibliotekanauki.pl/articles/131595.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Komisja Inżynierii Budowlanej PAN Oddział w Katowicach
Tematy:
thermal energy storage
hot water
mathematical model
magazynowanie energii cieplnej
woda ciepła
model matematyczny
Opis:
This paper is focused on an analysis of thermal energy performance of storage vessel[4]. This storage system consists of two concentric cylindrical containers made of concrete, between these two layers there is a thermal insulation layer – the vacuum-like one. The inner container is filled by water intended to operate as a heat accumulation medium and temperature of the water is assumed as 90ºC. The cooling process was simulated for a period of 30 days in the ANSYS software environment. The simulation showed that the analyzed type of heat storage vessel is able to keep the thermal Energy relatively efficiently.
Źródło:
Roczniki Inżynierii Budowlanej; 2015, 15; 11-16
1505-8425
Pojawia się w:
Roczniki Inżynierii Budowlanej
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies